MEDTRUM TECHNOLOGIES LQ002 USB Dongle User Manual 2

MEDTRUM TECHNOLOGIES Inc. USB Dongle 2

User Manual

1.Introducon
1.1 Indicaons for use
The USB dongle is indicated for use by paents at
home and healthcare professionals in a medical office
seng to facilitate communicaon between Medtrum
medical devices and a computer using the EasyView
Web Portal.
1.2 Contraindicaons
None know.
1.3 Warnings
Do NOT allow young children to hold the USB dongle
without adult supervision. The USB dongle may pose
a choking hazard.
1.4 Radio Frequency (RF) Communicaon
FCC Cauon
This device complies with part 15 of the FCC Rules.
Operaon is subject to the following two condions:
(1) This device may not cause harmful interference,
and (2) this device must accept any interference
received, including interference that may cause
undesired operaon.
Informaon to user
Any Changes or modificaons not expressly approved
by the party responsible for compliance could void the
user's authority to operate the equipment.
interference by one or more of the following
measures:
-Reorient or relocate the receiving antenna.
-Increase the separaon between the equipment and
receiver.
-Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV
technician for help.
* RF warning for Portable device:
The device has been evaluated to meet general RF
exposure requirement. The device can be used in
portable exposure condion without restricon.
IC Cauon
This device complies with Industry Canada licence-ex-
empt RSS standard(s).
Operaon is subject to the following two condions:
(1) This device may not cause interference, and (2)
This device must accept any interference, including
interference that may cause undesired operaon of
the device.
Le présent appareil est conforme aux CNR d'Industrie
Canada applicables aux appareils radio exempts de
licence. L'exploitaon est autorisée aux deux condi-
ons suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'ulisateur de l'appareil doit accepter tout
brouillage radioélectrique subi, même si le
brouillage est suscepble d'en compromere le
fonconnement.
Electronic devices that transmit in the same frequen-
cy band used by the USB dongle may prevent commu-
nicaon between the USB dongle and a Medtrum
medical device. This interference, however, does not
cause any incorrect data to be sent and does not
cause any harm to device.
1.5 Warranty Informaon
Medtrum Technologies Inc. (“Medtrum”) warrants its
USB dongle against defects in materials and work-
manship for the period of one year from the original
date of shipment of the USB dongle to the original
end use purchaser (the “Warranty Period”). During
the Warranty Period, Medtrum will, at its discreon,
either repair or replace (with a new or recerfied USB
dongle at Medtrum’s discreon) any defecve USB
dongle, subject to the condions and exclusions
stated herein. This Warranty applies only to new
devices and, in the event the USB dongle is repaired
or replaced, the warranty period shall not be extend-
ed.
The warranty is valid only if the USB dongle is used
in accordance with Medtrum’s instrucons and will
not apply:
• If damage results from changes or modificaons
made to the USB dongle by the user or third persons
aer the date of manufacture;
• If damage results from service or repairs performed
to any part of the USB dongle by any person or enty
other than Medtrum;
• If a non-Medtrum device is used with the USB
dongle;
• If damage results from a Force Majeure or other
event beyond the control of Medtrum; or
• If damage results from negligence or improper use,
including but not limited to improper storage or
physical abuse such as dropping or otherwise.
THE REMEDIES PROVIDED FOR IN THIS WARRANTY
ARE THE EXCLUSIVE REMEDIES AVAILABLE FOR ANY
WARRANT CLAIMS. NEITHER MEDTRUM NOR ITS
SUPPLIERS OR DISTRIBUTORS SHALL BE LIABLE FOR
ANY INCIDENTAL, CONSEQUENTIAL, OR SPECIAL
DAMAGE OF ANY NATURE OR KIND CAUSED BY OR
ARISING OUT OF A DEFECT IN THE PRODUCT. ALL
OTHER WARRANTIES, EXPRESSED OR IMPLIED, ARE
EXCLUDED, INCLUDING THE WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE.
2.Uploading data using the USB dongle
Your USB dongle must be properly installed before it
can transfer data from a Medtrum Personal Diabetes
Manager (PDM) or a transmier to the EasyView Web
Portal.
Connect the USB dongle to the USB port on your
computer via a USB cable. The white power indicator
light will be turned on once the dongle is properly
connected to a computer that is turned on.
If you want to upload data from a PDM, put it within
one meter of the dongle.
If you want to upload data from a transmier, snap
it into the dongle. If the transmier is faulty or not
compable with the dongle, the red fault indicator
light will be turned on.
Red fault
indicator light
Green data indicator light
White power
indicator light
11 23
4
Note: This equipment has been tested and found to
comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protecon against
harmful interference in a residenal installaon. This
equipment generates uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instrucons, may cause harmful
interference to radio communicaons. However, there
is no guarantee that interference will not occur in a
parcular installaon. If this equipment does cause
harmful interference to radio or television recepon,
which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the
The USB dongle can generate, use, and radiate radio
frequency energy, and may cause harmful interfer-
ence to radio communicaons. There are no guaran-
tees that interference will not occur in a parcular
installaon. If the USB dongle does cause harmful
interference to radio ecepon, you are encouraged to
try to correct the interference by one of the following
measures:
• Move or relocate the USB dongle.
• Increase the distance between the USB dongle and
the other device that is eming/receiving interfer-
ence.
This warranty shall be personal to the original end use
purchaser. Any sale, rental or other transfer or use of
the USB dongle covered by this warranty to or by a
user other than the original end use purchaser shall
cause this warranty to immediately terminate. This
warranty only applies to the USB dongle and does not
apply to other products or accessories.
Medtrum Ltd
Cibase Waord, 42-44 Clarendon Road
Waord, WD17 1JJ, United Kingdom
Tel: +44 (0)19 2331 2391
Medtrum Technologies Inc.
7F, Building 8, No. 200, Niudun Road
Shanghai 201203, China
Tel: +86-21-50274781
Fax: +86-21-50274779
www.medtrum.com
This product complies with Direcve
93/42/EEC (MDD) and Direcve
1995/5/EC (R&TTE).
CAN ICES-3 (B)/NMB-3(B)
REF MD-LQ-002
Version:1.0
Publicaon date: 6 Jan, 2017
UG782002GB
348140
©2017, Medtrum Technologies Inc. All rights reserved.
Log in to your EasyView Web Portal account and start
uploading data. During the data uploading process,
the green data indicator light on the USB dongle will
keep flashing. Once the data uploading is completed,
all the three indicator lights (the white power indica-
tor light, the green data indicator light and the red
fault indicator light) will flash five mes. Aer that,
only the white power light remains on unl the USB
dongle is disconnected from the computer.
3. Manufacturer’s Declaraon
The USB dongle is intended for use in the electromag-
nec environment specified below. The customer or
the user of USB dongle should make sure that it is
used in such an environment.
3.1 Electromagnec Emissions
Emissions Test Compliance
RF emissions
EN 60601-1-2:2007+AC:2010, IEC
60601-1-2:2007, CISPR
11:2009+A1:2010, and IEC
60601-1-2:2014
RF emissions
EN 60601-1-2:2007+AC:2010, IEC
60601-1-2:2007, CISPR
11:2009+A1:2010, and IEC
60601-1-2:2014
Group 1
Class B
Immunity Test Compliance
Level
±2.0 kV, ±4.0 kV,
±6.0kV, ±8.0 kV
contact
discharge
±2.0 kV, ±4.0 kV,
±8.0 kV, ±15.0
kV air discharge
±2.0 kV, ±4.0 kV,
±6.0 kV, ±8.0 kV
contact (56% RH)
±2.0 kV, ±4.0 kV,
±8.0 kV, ±15.0 kV
air (56% RH)
10 V/m
3.2 Electromagnec Immunity
IEC 60601 Test
Level
Electrostac
discharge (ESD)
IEC 61000-4-2
RF electromag-
nec field
immunity test
IEC 61000-4-3
10 V/m
Power frequency
magnec fields
IEC 61000-4-8
30 A/m 30 A/m
Warning:
1. The USB dongle should be avoided to use in the
environments near high voltage, high-intensity
magnec field, where the intensity of EM DISTUR-
BANCES is high.
2. Portable RF Communicaons equipment should be
used no closer than 30 cm (12 inches) to any part of
the Medtrum products. Otherwise, degradaon of
the performance of this equipment could result.
3. Use of this equipment adjacent to or stacked with
other equipment should be avoided, because it could
result in improper operaon. If such use is necessary,
this equipment and the other equipment should be
observed to verify that they are operang normally.
5.Appendix II: Technical Informaon
5.1 USB dongle Specificaons
Model: MD-LQ-002
Size: 70mm x 52mm x 23.3mm
Weight: 23 g
Operang Temperature Range: +5°C ~+40°C
Operang Relave Humidity Range: 20%~90%RH
Operang Atmospheric Pressure: 700~1060 hPa
Storage Temperature Range: -10°C~+55°C
Storage Relave Humidity Range: 20%~90%RH
Storage Atmospheric Pressure: 700~1060 hPa
Baery: 5V/1A
Limited Warranty: 1 year
Reference
number
Symbol Symbol
Meaning Meaning
Lot number
Do NOT use if
package is
damaged
4.Appendix I: Symbols and Icons
4.1 Product Label Symbols
SN
Manufacturer
Use by:
(yyyy-mm-dd)
Follow
instrucons
for use
Cauon: See
Instrucons for
use
IC
Waste
Electrical and
Electronic
Equipment
Storage
temperature
CE mark
Device serial
number
Authorized
representave
in the European
Community
Signifies
compliance with
Industry Canada
EMC and Radio
communicaons
requirements
567
Radio
communicaon
USB Dongle

Navigation menu