METRA INZENIRING D O O 0006P1389 Metra Wristband Collector User Manual Door Access Terminal Technical Manual

METRA INZENIRING D.O.O Metra Wristband Collector Door Access Terminal Technical Manual

Technical Manual

Download: METRA INZENIRING D O O 0006P1389 Metra Wristband Collector User Manual Door Access Terminal Technical Manual
Mirror Download [FCC.gov]METRA INZENIRING D O O 0006P1389 Metra Wristband Collector User Manual Door Access Terminal Technical Manual
Document ID3791307
Application IDjB9JVZY5RiNQg4JEJkat+A==
Document DescriptionTechnical Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize129.48kB (1618442 bits)
Date Submitted2018-03-22 00:00:00
Date Available2018-03-22 00:00:00
Creation Date2018-03-04 15:43:23
Producing SoftwareMicrosoft® Word 2016
Document Lastmod2018-03-04 15:43:23
Document TitleDoor Access Terminal Technical Manual
Document CreatorMicrosoft® Word 2016
Document Author: zbjelic

Metra Wristband Collector - Technical Manual
Metra Wristband Collector - Technical Manual [rev.2-030318]
2017 Metra inženiring d.o.o.
All Rights reserved.
No part of this manual may be reproduced in any form or by any means without prior written permission of Metra inženiring d.o.o.
The contents of this manual are subject to change without notice.
All efforts have been made to ensure the accuracy of the contents of this manual, however, should any errors be detected, Metra inženiring would greatly appreciate being informed of
them. Metra inženiring d.o.o. can assume no responsibility for any errors in this manual.
Table of contents
Metra Wristband Collector - Technical Manual ...................................................................................... 3
• Product Marking Label ..................................................................................................................... 4
• Product description .......................................................................................................................... 4
• Connections ...................................................................................................................................... 5
• Control Device connection ............................................................................................................ 5
• Control Device connector pin out details ...................................................................................... 6
• Terminal connection...................................................................................................................... 6
• Operating indicator .......................................................................................................................... 7
• DIP switch settings ........................................................................................................................... 7
• Application Code ........................................................................................................................... 7
• Operating Mode ............................................................................................................................ 8
• Capture Mode ............................................................................................................................... 8
• TEST Mode........................................................................................................................................ 8
• Test kit ........................................................................................................................................... 8
• Testing procedure ......................................................................................................................... 8
• Commands description................................................................................................................ 10
• Mounting instructions .................................................................................................................... 10
• PCB LED Indications and Inputs ...................................................................................................... 12
• Blok Scheme ................................................................................................................................... 12
• Technical data ................................................................................................................................ 13
Page 2
Metra Wristband Collector - Technical Manual
Metra Wristband Collector - Technical Manual
Manufacturer:
Trade Mark:
Model/Type ref.:
Part Number:
FCC ID:
Year of Construction:
Metra inženiring d.o.o.
IOC Trzin
Špruha 19
SI-1236 Trzin, Slovenia
Metra MEW System
Metra Wristband Collector
1389
2ABT80006P1389
2017
phone:
fax:
web:
+386 1 56 10 740
+386 1 56 10 744
www.metra.si
© 6th March 2017 Metra inženiring d.o.o.
All Rights reserved. The contents of this document are subject to change without notice.
This product is in conformity with the essential requirements and other relevant requirements of the
following EU Directives:
•
Radio and Telecommunications Terminal Equipment (R&TTE) Directive 2014/53/EU
•
RoHS Recast (RoHS2) Directive 2011/65/EU of the European Parliament and of the Council on the
restriction of the use of certain hazardous substances in electrical and electronics equipment.
Low Voltage Directive (LVD) 2014/35/EU that ensures that electrical equipment within certain voltage
limits provides a high level of protection for European citizens.
•
Environmental Information for EU customers – WEEE Directive Statement:
This symbol indicates the product is in conformity with the protection requirements of European Council
Directive 2012/19/EU. It requires that products marked with this symbol must not be disposed of with
unsorted municipal waste.
This product must be disposed of separately from household waste via designated collection facilities
appointed by local authorities. Please contact your local authorities or waste disposal service for more
detailed information.
Model/Type ref.: Metra Wristband Collector
Part Number: 1389
FCC ID: 2ABT80006P1389
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must accept any interference received, including interference that may
cause undesired operation.
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's
authority to operate the equipment.”
Page 3
Metra Wristband Collector - Technical Manual
• Product Marking Label
Product Marking Label is placed on the front right side of
the device (photo bellow).
Metra inženiring d.o.o. integrates “Metra Wristband
Collector” into different final products and is responsible
for proper labelling of the final product. The final
product’s label must include a statement “Contains FCC
ID: 2ABT80006P1389”.
• Product description
“Metra Wristband Collector” is a standalone
module which can be integrated into different
Metra access control systems. It is used
whenever RFID Wristband has to be retained
when a guest leaves the facility. It grants the exit
signal only when the Wristband (ticket) is
successfully erased and retained. This
dramatically cuts costs of the system operation
and the chance of fraud. That innovative product
Metra first developed and patented in 1998
together with contactless RFID Wristband.
“Metra Wristband Collector” can be integrated
into different Metra access control products
such as Tripod Turnstile, Metra Access Terminal
or similar.
It is presented to the retaining device.
Page 4
Metra Wristband Collector - Technical Manual
• Connections
description
ISP Loader
COM (Terminal)
description
Power and Metra EasyWire
*NOTE: Metra EasyWire connection must be connected for the Wristband Collector to communicate
with the Control Device; not needed for TEST mode of operation. See next chapter for details.
• Control Device connection
 WARNING 
• Mind the power and Metra EasyWire polarity! Wrong polarity could result in irreparable damage
to the device.
• Respect power requirements data! Using unsuitable power supply could result in damage to the
power supply and to the device.
Page 5
Metra Wristband Collector - Technical Manual
Regulated DC power supply is required for proper
operation. See chapter “Technical Data” for power
requirements.
Connect regulated power supply and Metra EasyWire
cable to designated terminals as shown on the picture.
For control device connector pin out details see next
chapter.
• Control Device connector pin out details
• Terminal connection
Terminal connection is intended for TEST mode of operation.
Connect the RS-232 serial cable as shown on the picture. For further information see chapter “TEST
Mode”.
Page 6
Metra Wristband Collector - Technical Manual
• Operating indicator
When the unit is running, Metra logo on the front panel is blinking.
• DIP switch settings
By changing the DIP Switch pins position, different operating modes and parameters can be set. To
change between different operating modes, use a small flat screwdriver or similar object to push DIP
switch pins to desired position.
• Application Code
Look up the code for desired application in the coding table below. Set switches #3 and #4 to
indicated positions, where:
• 0 indicates the corresponding switch is in OFF position (switch down)
• 1 indicates the corresponding switch is in ON position (switch up)
switch positions
application code
Reserved
Reserved
009 ISO
Reserved
Page 7
Metra Wristband Collector - Technical Manual
 NOTE 
Always select only the application that is supported by the connected reader!
 NOTE 
The new application code will take effect after the next device power-up!
• Operating Mode
Set switch #6 to desired position, where:
• OFF position (switch down) activates NORMAL mode
• ON position (switch up) activates TEST mode
 NOTE 
The device should always operate in NORMAL mode.
• Capture Mode
Set switch #3 to desired position, where:
• OFF position (switch down) activates CLOSED mode
• ON position (switch up) activates OPEN mode
In the CLOSED mode the device cover is open only when proper wristband is presented, otherwise
the cover is closed.
In the OPEN mode the cover is always open and the wristband to be captured can be introduced
directly on to the capture pan.
• TEST Mode
• Test kit
Kit is used for TEST mode of operation.
Kit includes:
• Power Supply Unit
• RS-232 serial cable
• Testing procedure
 NOTE 
The TEST Mode is intended for factory testing and maintenance purposes only!
Page 8
Metra Wristband Collector - Technical Manual
STEP 1:
With the power switched off connect the RS-232 serial cable as indicated in “Terminal connection”
chapter.
STEP 2:
Run ASCII terminal program on your computer (Figures indicate the Hyper Terminal application for
MS Windows®). Set communication parameters:
STEP 3:
Set the DIP switch #6 to ON (switch up) to activate the TEST mode of operation.
STEP 4:
Switch the power on. Upon the device start-up, a list of all available commands is listed in the
terminal window:
STEP 5:
Run the selected command by pressing the appropriate key. Any number of commands can be
executed one after another. For the commands list, press .
STEP 6:
When finished, set the DIP switch #6 to OFF (switch down) to return to the NORMAL mode of
operation.
Page 9
Metra Wristband Collector - Technical Manual
• Commands description
Cover / Pan sensors test:
Each time one of the hall sensors changes state, the WBC will beep shortly. The corresponding LED
(the green ‘operate’ LED for the back sensor and the red ‘error’ LED for the front sensor) indicates
the state of the sensor. Press any key to finish the test.
Cover / Pan antenna test:
Approach the RFID tag to the antenna to be tested. Close the cover when testing the cover antenna
and open the cover when testing the pan antenna. Each time the tag comes in or out of the antenna
field, the WBC will beep shortly. All LEDs will be turned ON while the tag is in the antenna field. Press
any key to finish the test.
Move cover / pan to front / back:
The command will drive the appropriate motor to execute the selected move. The motor will be
turned OFF when the corresponding sensor is activated or after the timeout occurs.
Complex motor test:
The command will execute the following moves: the cover to back, the pan to back, the pan to front,
the cover to front. For the command to be effective, both the cover and the pan should be in the
front position before executing.
Signals test:
The command will consecutively turn ON the green LED, the red LED and the pan illumination,
beeping shortly after each operation. After a short delay all the signals will be turned OFF.
Version and settings:
The command will return the current firmware version and text description of the DIP switch
settings.
Help:
All the available commands for the current operating mode will be listed.
• Mounting instructions
Mounting slides positions
on the Wristband Capturer
Mounting guides positions
on the mounting surface
Page 10
Metra Wristband Collector - Technical Manual
STEP 1: Position the capturer
Put the Wristband Capturer onto the provided mounting
surface so that the mounting slides of the Wristband
Capturer mate with the mounting guides of the mounting
surface.
STEP 2: Secure the position
Push the Wristband Capturer housing towards the
mounting surface (red arrows), then push the metal
carrier plate against the cover back wall (green arrow) to
secure the position and then tighten the nut (blue
arrow).
STEP 3: Connect the Power/Local CAN
Check that no cables are in the way of the wristband
collecting pan or the flip antenna.
Page 11
Metra Wristband Collector - Technical Manual
• PCB LED Indications and Inputs
• Blok Scheme
Page 12
Metra Wristband Collector - Technical Manual
• Technical data
Operating voltage
Current consumption
Operating temperature range
Visual signalization
Built-in RFID readers
RFID Antennas
24V DC regulated
0.5A average / 1.4 A max.
-10 °C to +50 °C
Blue, red and green LEDs.
Two RFID Readers that read ISO 15693, ISO 1443A, ISO 14443B
compatible RFID media.
Two passive antennas tuned to 13.56 MHz.
Connections
1x MEW, 1x Power
Dimensions
234 x 171 x 78 mm
Page 13

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Page Count                      : 12
Language                        : en-GB
Tagged PDF                      : Yes
XMP Toolkit                     : 3.1-701
Producer                        : Microsoft® Word 2016
Title                           : Door Access Terminal Technical Manual
Creator                         : zbjelic
Creator Tool                    : Microsoft® Word 2016
Create Date                     : 2018:03:04 15:43:23+01:00
Modify Date                     : 2018:03:04 15:43:23+01:00
Document ID                     : uuid:66D035FE-132C-4743-8BD9-7C337BBD2284
Instance ID                     : uuid:66D035FE-132C-4743-8BD9-7C337BBD2284
Author                          : zbjelic
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2ABT80006P1389

Navigation menu