MOBOTIX PROXCE MX-Proximity-Box User Manual manual part 1
MOBOTIX AG MX-Proximity-Box manual part 1
MOBOTIX >
Contents
- 1. manual_part_1.pdf
- 2. manual_part_2.pdf
manual_part_1.pdf
Standard Delivery MX-Proximity-Box • • • • • • • • Quick Install MX-Proximity-Box Motion Detection with Radar Sensor Technology MX-Proximity-Box 1 screwdriver 1 plug 3 to 5 mm 1 plug 5 to 7 mm 1 MxBus cable 0.5 m/1.64 ft 2 washers 4.3 mm dia. 2 stainless steel wood screws 4x40 mm 2 screw anchors S6 Radar-based detection for any camera with MxBus connector More information: www.mobotix.com > Products > Accessories > Interface Boxes MX-PROX-BOX 32.765-001_EN_10/2016 Connection Example MOBOTIX MX-Proximity-Box MX-PROX-BOX LED MOBOTIX IP Video Door Station MX-T25M-Sec-D11 LED Radar sensor 2-wire MxBus wiring to camera (max. 100 m/328 ft) MOBOTIX Camera Installation Instructions 1. Find a good location for installing Select the location for installing the device so that the objects you want to detect are within the detection area of the box (80° horizontally, 34° vertically). Note that the detection precision is best if the objects are moving perpendicular to the front label of the MX-Proximity-Box: rims stick out equally on both sides. Push the cable through the plug, remove the sheath on a length of 15 mm/0.6 in and strip the insulation of the wires for about 5 mm/0.2 in. 34° vertically 80° horizontally 2. Attach the box Attach the MX-Proximity-Box at the mounting position with the cable ports pointing downwards. Next, remove the box cover (three screws). 4. Connect the MxBus wires to the terminal Connect the MxBus wires to the terminals of the MX-Proximity-Box using the screwdriver. Make sure to maintain the polarity (see sticker on the front of the terminal). 5. Mount the cover Mount the cover back onto the MX-Proximity-Box and affix it using the cover screws. 6. Connect the MxBus wires to the opposite side 3. Prepare the connection cables Before proceeding, make sure there is no current on the MxBus wires! Cut the MxBus wires to size (2-wire, 0.6–0.8 mm diameter). When using wires without sheath, strip the insulation of the wires for 5 mm and push the wires through the eight-wire plug (left). Connect the MxBus wires as described in the corresponding manual to the MOBOTIX camera or to another MxBus module connected to a camera (e.g. KeypadRFID, MX-DoorMaster). Make sure not to exceed the overall length of the MxBus wiring (max. 100 m/328 ft). MxBus plug in MOBOTIX camera When using a cable with jacket (e.g., J-Y(St)Y), remove the pre-installed eight-wire plug and insert the appropriate cable plug (3 to 5 mm or 5 to 7 mm). Press the rubber plug into the casing in such a way that the LED Signaling Operating Status Radar Signal LED Meaning Not connected Operating status (left) Regular operation Unencrypted communication Error during communication Radar signal (right) LED off LED permanently on LED blinking Leaving Approaching Movement The intensity of the LEDs varies depending on the strength of the reflected radar waves. Initial Operation of the MX-Proximity-Box 1. Open the MOBOTIX camera's user interface in the browser • Enter the IP address of the camera that is connected to the MX-Proximity-Box in the browser (admin access rights required): http://2. Activate MxBus interface and MX-Proximity-Box • Open the Admin Menu > Hardware Configuration > Manage MxBus Modules dialog. • Make sure that the MxBus Interface is connected. If the interface is not connected, click on Connect. • In the Device section, check if the MX-Proximity-Box line is set to Active. If this is not the case, click on Refresh. 3. Configure MX-Proximity-Box • In the same dialog as in step 2, click on MxMessageSystem Configuration. • Click on Load configuration of connected devices. • Click on Edit Messages, then on New message and enter a suitable Message name. • Select the Message name. The Recurrence time specifies the time to pause before the message can be sent again. • In addition, you can select a movement profile for triggering events. The predefined Approaching, Leaving and Movement profiles combine the corresponding parameters. The Custom profile allows setting individual values for special purposes. • In order to store the MX-Proximity-Box configuration, click on Transfer entire configuration. 4. Configure events • Open the Setup Menu > Event Control > Event Overview dialog. • In the Message Events section, click on Edit and create the profiles for message events as required (e.g., for starting a recording). 5. Store the camera configuration • In the Live screen of the camera, click on Admin Menu > Configuration > Store, permanently store the camera configuration and reboot the camera. • Click on the bar with the desired MX-Proximity-Box, then on Add. Resetting the MX-Proximity-Box If the MX-Proximity-Box had been connected to a different camera before and was not deactivated or reset before detaching, the left LED (operating status) may flash red after establishing the connection. In this case, you need to reset the connected and activated MX-Proximity-Box to factory defaults: times to indicate that the process has finished successfully. • Mount the cover back onto the box. • Set up the MX-Proximity-Box in the camera (see «Initial Operation of the MX-Proximity-Box»). • Remove the box cover. • Bridge the contact surfaces in the bottom right corner (red circle in figure) using a screwdriver, for example (both LEDs are flashing red/blue with increasing frequency). • Only remove the bridge if both LEDs of the MX-Proximity-Box are flashing green on/off 3 Safety Warnings • This product must not be used in locations exposed to the dangers of explosion. • Make sure that you install this product as outlined in the installation instructions above. • The MOBOTIX MX-Proximity-Box is to be used only for detecting movements using radar sensors in IP66 environments. • Electrical systems and equipment may only be installed, modified and maintained by a qualified electrician or under the direction and supervision of a qualified electrician in accordance with the applicable electrical guidelines. Make sure to properly set up all electrical connections. • Torque for all screws: 0.4 Nm. • Press the white cable plug (eight-wire plug or cable plug 3 to -5 mm or 5 to -7 mm) into the casing in such a way that the rims stick out equally on both sides. • Make sure to use only twisted-pair cabling (e.g., J-Y(St)Y) for MxBus wiring. • The length of the entire MxBus wiring must not exceed 100 m/328 ft. • Diameter of all wires: 0.6–0.8 mm (0.8 mm = AWG 21 recommended to reduce line losses). • Make sure that you adhere to all relevant laws, regulations and that you fulfill all certification requirements for the intended use. Technical Specifications MX-Proximity-Box Connection MxBus (2 terminals) Power Supply 48 V DC (via camera and MxBus) Power consumption 0.5 to 1 W Frequency (radar signal) ~24 GHz Operating Conditions IP66 (DIN EN 60529) –20 to +60 °C/–4 to +140 °F Dimensions (height x width x depth) 63 x 87 x 30 mm Materials Housing: PBT GF30 Weight Approx. 75 g/0.17 lb Detection area Human: 0 to max. 6 m/19.69 ft; car: 0 to max. 20 m/21.87 yd Further Information regarding detection Up to 15 kph/9.3 mph: Approaching, leaving and general motion detection More than 15 kph/9.3 mph: General motion detection (precision will decrease with increasing distance and speed and with decreasing object size) Drilling templates for other MOBOTIX components: www.mobotix.com > Support > Manuals Drilling Template 75 mm/2.95 in MX-Proximity-Box This device is granted pursuant to the Japanese Radio Law (電波法) This device should not be modified (otherwise the granted designation number will become invalid) MOBOTIX, the MX logo, MxControlCenter, MxEasy, MxPEG and MxActivitySensor are trademarks of MOBOTIX AG registered in the European Union, the U.S.A., and other countries • Information subject to change without notice • MOBOTIX does not assume any liability for technical or editorial errors or omissions contained herein • All rights reserved • © MOBOTIX AG 2016 Declaration of Conformity: www.mobotix.com > Support > Media Library > Certificates MOBOTIX AG Kaiserstrasse D-67722 Langmeil Phone: +49 6302 9816-103 Fax: +49 6302 9816-190 sales@mobotix.com www.mobotix.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes Language : de-DE XMP Toolkit : Adobe XMP Core 5.6-c123 79.158978, 2016/02/13-01:11:19 Format : application/pdf Title : MX-Proximity-Box – Quick Install – EN Rights : Copyright © 1999 – 2016, MOBOTIX AG Creator : Thilo Schüller, MOBOTIX AG Create Date : 2016:10:10 16:20:50+02:00 Metadata Date : 2016:10:10 16:21:01+02:00 Modify Date : 2016:10:10 16:21:01+02:00 Creator Tool : Adobe InDesign CC 2015 (Macintosh) Instance ID : uuid:65a556a9-bcf8-dd4f-809c-25c1db4b5c5a Original Document ID : xmp.did:F77F117407206811BF36C8830FB68B39 Document ID : xmp.id:1d3e0246-14e0-440f-8ec8-1a852f2089cb Rendition Class : proof:pdf History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2015 (Macintosh) History Changed : / History When : 2016:10:10 16:20:50+02:00 Derived From Instance ID : xmp.iid:a28b23c2-3e27-41e8-a8f8-e8e83ef16acc Derived From Document ID : xmp.did:71731235-80d9-4ce8-b862-cb334844532d Derived From Original Document ID: xmp.did:F77F117407206811BF36C8830FB68B39 Derived From Rendition Class : default Marked : True Producer : Adobe PDF Library 15.0 Trapped : False Page Layout : TwoPageRight Page Count : 2 Author : Thilo Schüller, MOBOTIX AGEXIF Metadata provided by EXIF.tools