MOBOTIX PROXCE MX-Proximity-Box User Manual manual part 1

MOBOTIX AG MX-Proximity-Box manual part 1

Contents

manual_part_1.pdf

Download: MOBOTIX PROXCE MX-Proximity-Box User Manual manual part 1
Mirror Download [FCC.gov]MOBOTIX PROXCE MX-Proximity-Box User Manual manual part 1
Document ID3257948
Application ID05+J7Iy/CULg6tAg+PzP3A==
Document Descriptionmanual_part_1.pdf
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize71.29kB (891126 bits)
Date Submitted2017-01-13 00:00:00
Date Available2017-01-13 00:00:00
Creation Date2016-10-10 16:20:50
Producing SoftwareAdobe PDF Library 15.0
Document Lastmod2016-10-10 16:21:01
Document TitleMX-Proximity-Box – Quick Install – EN
Document CreatorAdobe InDesign CC 2015 (Macintosh)
Document Author: Thilo Schüller, MOBOTIX AG

Standard Delivery
MX-Proximity-Box
•
•
•
•
•
•
•
•
Quick Install
MX-Proximity-Box
Motion Detection with Radar
Sensor Technology
MX-Proximity-Box
1 screwdriver
1 plug 3 to 5 mm
1 plug 5 to 7 mm
1 MxBus cable 0.5 m/1.64 ft
2 washers 4.3 mm dia.
2 stainless steel wood screws 4x40 mm
2 screw anchors S6
Radar-based detection for any
camera with MxBus connector
More information:
www.mobotix.com > Products > Accessories > Interface Boxes
MX-PROX-BOX
32.765-001_EN_10/2016
Connection Example
MOBOTIX MX-Proximity-Box
MX-PROX-BOX
LED
MOBOTIX IP Video Door Station
MX-T25M-Sec-D11
LED
Radar sensor
2-wire MxBus wiring to camera
(max. 100 m/328 ft)
MOBOTIX Camera
Installation Instructions
1. Find a good location for installing
Select the location for installing the device so that the
objects you want to detect are within the detection area
of the box (80° horizontally, 34° vertically). Note that
the detection precision is best if the objects are moving
perpendicular to the front label of the MX-Proximity-Box:
rims stick out equally on both sides. Push the cable
through the plug, remove the sheath on a length of
15 mm/0.6 in and strip the insulation of the wires for
about 5 mm/0.2 in.
34° vertically
80° horizontally
2. Attach the box
Attach the MX-Proximity-Box at the mounting position
with the cable ports pointing downwards. Next, remove
the box cover (three screws).
4. Connect the MxBus wires to the terminal
Connect the MxBus wires to the terminals of the
MX-Proximity-Box using the screwdriver. Make sure
to maintain the polarity (see sticker on the front of
the terminal).
5. Mount the cover
Mount the cover back onto the MX-Proximity-Box and
affix it using the cover screws.
6. Connect the MxBus wires to the opposite side
3. Prepare the connection cables
Before proceeding, make sure there is no current on
the MxBus wires!
Cut the MxBus wires to size (2-wire, 0.6–0.8 mm diameter). When using wires without sheath, strip the insulation
of the wires for 5 mm and push the wires through the
eight-wire plug (left).
Connect the MxBus wires as described in the corresponding manual to the MOBOTIX camera or to another
MxBus module connected to a camera (e.g. KeypadRFID,
MX-DoorMaster). Make sure not to exceed the overall
length of the MxBus wiring (max. 100 m/328 ft).
MxBus plug
in MOBOTIX
camera
When using a cable with jacket (e.g., J-Y(St)Y), remove
the pre-installed eight-wire plug and insert the appropriate cable plug (3 to 5 mm or 5 to 7 mm). Press the
rubber plug into the casing in such a way that the
LED Signaling
Operating Status
Radar Signal
LED
Meaning
Not connected
Operating
status
(left)
Regular operation
Unencrypted communication
Error during communication
Radar signal
(right)
LED off
LED permanently on
LED blinking
Leaving
Approaching
Movement
The intensity of the LEDs varies depending on the strength of
the reflected radar waves.
Initial Operation of the MX-Proximity-Box
1. Open the MOBOTIX camera's user interface in
the browser
• Enter the IP address of the camera that is connected to the MX-Proximity-Box in the browser
(admin access rights required):
http://
2. Activate MxBus interface and MX-Proximity-Box
• Open the Admin Menu > Hardware Configuration > Manage MxBus Modules dialog.
• Make sure that the MxBus Interface is connected.
If the interface is not connected, click on Connect.
• In the Device section, check if the MX-Proximity-Box
line is set to Active. If this is not the case, click
on Refresh.
3. Configure MX-Proximity-Box
• In the same dialog as in step 2, click on
MxMessageSystem Configuration.
• Click on Load configuration of connected devices.
• Click on Edit Messages, then on New message
and enter a suitable Message name.
• Select the Message name. The Recurrence time
specifies the time to pause before the message
can be sent again.
• In addition, you can select a movement profile for
triggering events. The predefined Approaching,
Leaving and Movement profiles combine the
corresponding parameters. The Custom profile
allows setting individual values for special purposes.
• In order to store the MX-Proximity-Box configuration, click on Transfer entire configuration.
4. Configure events
• Open the Setup Menu > Event Control > Event
Overview dialog.
• In the Message Events section, click on Edit and
create the profiles for message events as required
(e.g., for starting a recording).
5. Store the camera configuration
• In the Live screen of the camera, click on Admin
Menu > Configuration > Store, permanently store
the camera configuration and reboot the camera.
• Click on the bar with the desired MX-Proximity-Box,
then on Add.
Resetting the MX-Proximity-Box
If the MX-Proximity-Box had been connected to a
different camera before and was not deactivated or
reset before detaching, the left LED (operating status)
may flash red after establishing the connection. In this
case, you need to reset the connected and activated
MX-Proximity-Box to factory defaults:
times to indicate that the process has finished
successfully.
• Mount the cover back onto the box.
• Set up the MX-Proximity-Box in the camera (see
«Initial Operation of the MX-Proximity-Box»).
• Remove the box cover.
• Bridge the contact surfaces in the bottom right
corner (red circle in figure) using a screwdriver,
for example (both LEDs are flashing red/blue with
increasing frequency).
• Only remove the bridge if both LEDs of the
MX-Proximity-Box are flashing green on/off 3
Safety Warnings
• This product must not be used in locations exposed
to the dangers of explosion.
• Make sure that you install this product as outlined
in the installation instructions above.
• The MOBOTIX MX-Proximity-Box is to be used only
for detecting movements using radar sensors in IP66
environments.
• Electrical systems and equipment may only be
installed, modified and maintained by a qualified
electrician or under the direction and supervision of
a qualified electrician in accordance with the applicable electrical guidelines. Make sure to properly set
up all electrical connections.
• Torque for all screws: 0.4 Nm.
• Press the white cable plug (eight-wire plug or cable
plug 3 to -5 mm or 5 to -7 mm) into the casing in such
a way that the rims stick out equally on both sides.
• Make sure to use only twisted-pair cabling (e.g.,
J-Y(St)Y) for MxBus wiring.
• The length of the entire MxBus wiring must not exceed
100 m/328 ft.
• Diameter of all wires: 0.6–0.8 mm (0.8 mm = AWG 21
recommended to reduce line losses).
• Make sure that you adhere to all relevant laws, regulations and that you fulfill all certification requirements
for the intended use.
Technical Specifications
MX-Proximity-Box
Connection
MxBus (2 terminals)
Power Supply
48 V DC (via camera and MxBus)
Power consumption
0.5 to 1 W
Frequency (radar signal)
~24 GHz
Operating Conditions
IP66 (DIN EN 60529)
–20 to +60 °C/–4 to +140 °F
Dimensions (height x width x
depth)
63 x 87 x 30 mm
Materials
Housing: PBT GF30
Weight
Approx. 75 g/0.17 lb
Detection area
Human: 0 to max. 6 m/19.69 ft; car: 0 to max. 20 m/21.87 yd
Further Information regarding
detection
Up to 15 kph/9.3 mph: Approaching, leaving and general motion
detection
More than 15 kph/9.3 mph: General motion detection (precision will
decrease with increasing distance and speed and with decreasing
object size)
Drilling templates for other MOBOTIX components:
www.mobotix.com > Support > Manuals
Drilling Template
75 mm/2.95 in
MX-Proximity-Box
This device is granted pursuant to the Japanese Radio Law (電波法)
This device should not be modified (otherwise the granted designation number will become invalid)
MOBOTIX, the MX logo, MxControlCenter, MxEasy, MxPEG and MxActivitySensor are trademarks of MOBOTIX AG
registered in the European Union, the U.S.A., and other countries • Information subject to change without notice
• MOBOTIX does not assume any liability for technical or editorial errors or omissions contained herein • All rights
reserved • © MOBOTIX AG 2016
  
Declaration of Conformity: www.mobotix.com > Support > Media Library > Certificates
MOBOTIX AG
Kaiserstrasse
D-67722 Langmeil
Phone: +49 6302 9816-103
Fax: +49 6302 9816-190
sales@mobotix.com
www.mobotix.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : Yes
Language                        : de-DE
XMP Toolkit                     : Adobe XMP Core 5.6-c123 79.158978, 2016/02/13-01:11:19
Format                          : application/pdf
Title                           : MX-Proximity-Box – Quick Install – EN
Rights                          : Copyright © 1999 – 2016, MOBOTIX AG
Creator                         : Thilo Schüller, MOBOTIX AG
Create Date                     : 2016:10:10 16:20:50+02:00
Metadata Date                   : 2016:10:10 16:21:01+02:00
Modify Date                     : 2016:10:10 16:21:01+02:00
Creator Tool                    : Adobe InDesign CC 2015 (Macintosh)
Instance ID                     : uuid:65a556a9-bcf8-dd4f-809c-25c1db4b5c5a
Original Document ID            : xmp.did:F77F117407206811BF36C8830FB68B39
Document ID                     : xmp.id:1d3e0246-14e0-440f-8ec8-1a852f2089cb
Rendition Class                 : proof:pdf
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2015 (Macintosh)
History Changed                 : /
History When                    : 2016:10:10 16:20:50+02:00
Derived From Instance ID        : xmp.iid:a28b23c2-3e27-41e8-a8f8-e8e83ef16acc
Derived From Document ID        : xmp.did:71731235-80d9-4ce8-b862-cb334844532d
Derived From Original Document ID: xmp.did:F77F117407206811BF36C8830FB68B39
Derived From Rendition Class    : default
Marked                          : True
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Layout                     : TwoPageRight
Page Count                      : 2
Author                          : Thilo Schüller, MOBOTIX AG
EXIF Metadata provided by EXIF.tools
FCC ID Filing: YYRPROXCE

Navigation menu