MSA Innovation FPAC34 M2M Gateway User Manual

Sierra Monitor Corporation M2M Gateway Users Manual

Users Manual

Download: MSA Innovation FPAC34 M2M Gateway User Manual
Mirror Download [FCC.gov]MSA Innovation FPAC34 M2M Gateway User Manual
Document ID3111872
Application IDoVmaJWHo7xL7dHXky3pcYA==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize37.43kB (467881 bits)
Date Submitted2016-08-25 00:00:00
Date Available2016-08-25 00:00:00
Creation Date2017-12-13 08:51:43
Producing SoftwareGPL Ghostscript 9.18
Document Lastmod2017-12-13 08:51:43
Document TitleMicrosoft Word - User Manual_FPA-C34 and FPA-W34 V1.5 for FCC and IC 20160816A.docx
Document CreatorPScript5.dll Version 5.2.2
Document Author: x.fu

FPA-C34, FPA-W34
FPA-C34, FPA-W34
User’s Manual
1/ 17
FPA-C34, FPA-W34
Chengdu Vantron Technology, Ltd.
www.vantrontech.com.cn
Revision History:
No.
Version
Description
V1.0
Initial Version
2015.01.17
V1.1
Add DIP Switch explain
2015.01.25
V1.2
V1.3
Add some pictures to function
Change some pictures to function
2015.02.01
2015.02.04
V1.4
V1.5
Statement Vantron is the manufacturer to the
device, and SMC is the customer of the device
Require professionally install antennas and use
antennas specified by the manufacturer
2/ 17
Date
2016/7/19
2016/8/3
FPA-C34, FPA-W34
Table of Contents
1.
Foreword ................................................................................................................................ 4
1.1 Copyright Notice ........................................................................................................................4
1.2 Notes ..........................................................................................................................................4
1.3 Statement ...................................................................................................................................4
1.4 Disclaimer ...................................................................................................................................4
1.5 Limitation of Liability/Non‐warranty ..........................................................................................4
1.6 Safety Instructions ......................................................................................................................5
1.7 Precautions.................................................................................................................................5
2.
3.
1.8 Safety Instructions for Power Cables and Accessories ...............................................................5
Overview ................................................................................................................................ 7
2.1 Introduction ...............................................................................................................................7
M2M Gateway‐ FPA‐C34, FPA‐W34 Hardware Instructions ...................................................... 9
3.1 Product Appearance ...................................................................................................................9
3.5 Interface Description ............................................................................................................... 10
3.5.1 Power Interface ........................................................................................................ 10
3.5.2 Ethernet Interface .................................................................................................... 10
3.5.3 RS232 or RS485 Connector ...................................................................................... 11
3.5.3 DIP Switch for select ................................................................................................ 11
3.5.3 DIP Switch for boot .................................................................................................. 11
3.5.6 LED ........................................................................................................................... 12
3.5.7 Micro SIM Card ........................................................................................................ 12
3.5.8 DEBUG...................................................................................................................... 12
3.5.9 Renew button .......................................................................................................... 12
4.
3.5.12 SD/MMC socket ..................................................................................................... 13
Tips ...................................................................................................................................... 14
3/ 17
FPA-C34, FPA-W34
1. Foreword
1.1 Copyright Notice
While all information contained herein have been carefully checked to assure its
accuracy in technical details and printing, Vantron assumes no responsibility resulting
from any error or features of this manual, or from improper uses of this manual or
the software. Please contact our technical department for relevant operation
solutions if there is any problem that cannot be solved according to this manual.
Vantron reserves all rights of this manual, including the right to change the content,
form, product features, and specifications contained herein at any time without prior
notice. The latest version of this manual is at www.vantrontech.com.cn. Please
contact Vantron for further information:
Vantron Technology Vantron
E‐mail: sales@vantrontech.com
The trademarks and registered trademarks in this manual are properties of their
respective owners. No part of this manual may be copied, reproduced, translated or
sold. No changes or other purposes are permitted without the prior written consent
of Vantron.
Vantron reserves the right of all publicly‐released copies of this manual.
1.2 Notes
Applicable notes are listed in the following table:
Sign
Notice Type
Description
Notice
Important information and regulations
Caution
Caution for latent damage to system or harm to personnel
1.3 Statement
It is recommended to read and comply with this manual before operating FPA‐C34,
FPA‐W34 which provides important guidance and helps decreasing the danger of
injury, electric shock, fire, or any damage to the device.
1.4 Disclaimer
Vantron assumes no legal liability of accidents resulting from failure of conforming
to the safety instructions.
1.5 Limitation of Liability/Non‐warranty
4/ 17
FPA-C34, FPA-W34
For direct or indirect damage to this device or other devices of Vantron caused by
failure of conforming to this manual or the safety instructions on device label,
Vantron assumes neither warranty nor legal liability even if the device is still under
warranty.
The FPA‐C34, FPA‐W34 should be installed, debugged and maintained by
professional people.
The outside antennas are not permitted to be installed or to be changed by non‐
professional people. To run the device normally, only specify antennas are approved
to be assembled together by professional people.
Unit shall be used with indoor‐use antenna only. No antenna for this unit can be
installed outdoor.
1.6 Safety Instructions
 Keep and comply with all operation instructions, warnings, and information.
 Pay attention to warnings on this device.
 Read the following precautions so as to decrease the danger of injury, electric
shock, fire, or any damage to the device.
1.7 Precautions




Pay attention to the product labels/safety instructions printed on silk screens.
Do not try repairing this product unless declared in this manual.
Keep away from heat source, such as heater, heat dissipater, or engine casing.
Do not insert other items into the slot (if any) of this device.
• Keep the ventilation slot ventilated for cooling.
•System fault may arise if other items are inserted into this device.
 Installation: ensure correct installation according to instructions from the
manufacturer with recommended installation tools.
 Ensure ventilation and smoothness according to relevant ventilation standard.
1.8 Safety Instructions for Power Cables and Accessories
Proper power source only
Start only with power source that satisfies voltage label and the voltage necessary
according to this manual. Please contact technical support personnel of Vantron for
any uncertainty about the requirements of necessary power source.
Use tested power source
This product still contains a button lithium battery as a real‐time clock after its
external power source is removed and therefore should not be short‐circuited during
transportation or placed under high temperature.
5/ 17
FPA-C34, FPA-W34
Place cables properly:
Do not place cables at any place with extrusion danger.





Cleaning Instructions
Please power off before cleaning the device.
Do not use spray detergent.
Clean with a damp cloth.
Do not try cleaning exposed electronic components unless with a dust collector.
Support for special fault: Power off and contact technical support personnel of
Vantron in case of the following faults:
 The device is damaged.
 The temperature is excessively high.
 Fault is still not solved after the operation according to the manual.
6/ 17
FPA-C34, FPA-W34
2. Overview
2.1 Introduction
Thank you for choosing Vantron. It is our commitment to provide our valued
customers with the embedded devices equipped with the state‐of‐the‐art
technology and the best product services.
Vantron’s M2M products are based on the most advanced ARM and Intel Atom
processors and have low‐power consumption and high integration. The products are
designed for applications of M2M in industrials, medicals, financial, retail, vehicle,
and transportations etc.
2.2 How to setup and use the device
To use the device, please install the unit stably, and assemble its antenna(s) for
WLAN(BlueTooth), CELL and possible GPS, if the device is configured for CELL function, maybe you
need to activate the SIM card against proper carrier, and then please insert correct 12‐24V DC
cable to the power jack of the device, the device will be powered up and the PWR LED lighting
indicates the system boots up. The device have a standard RJ45 Ethernet port which supporting
10M/100M Full/Half Duplex.
The device integrates a Web Page Subsystem to provide a web page for user to control the
system. The default IP address is “192.168.0.1”, the default username and password are
“root/admin”. You can setup such as WAN, Network, CELL, Wireless via web page. Follow
guidelines of application software for further comment to the device usage please.
7/ 17
FPA-C34, FPA-W34
8/ 17
FPA-C34, FPA-W34
3. M2M Gateway‐ FPA‐C34, FPA‐W34 Hardware Instructions
3.1 Product Appearance
Front Side View
Light Side View
9/ 17
FPA-C34, FPA-W34
3.5 Interface Description
3.5.1 Power Interface
PIN1
Power connector outlook
Pin
Description
Power input range 12‐24V
Ground
Shell ground
3.5.2 Ethernet Interface
Standard RJ45 interface, supporting 10M/100M Full/Half Duplex, this is a
standard RJ45 Ethernet port
Pin
10
11
12
Description
ETH_TX+
ETH_TX‐
ETH_RX+
ETH_RX‐
ETH_CT
ETH_CT
NC
DGND
LEDG+
LEDG‐
LEDG+
LEDG‐
10/ 17
Remarks
IO
IO
FPA-C34, FPA-W34
3.5.3 RS232 or RS485 Connector
Standard vertical 1x3x3.81mm male Terminal Block.
Pin
Description
TXD1 or RS485_A
RXD1 or RS485_B
DGND
Remarks
IO
IO
3.5.3 DIP Switch for select
Bit
Description
ON: have matched resistance of 120 ohm
OFF: have no
ON: have pull up resister of 510 ohm
OFF: have no
ON: have pull down resister of 510 ohm
OFF: have no
ON: select RS232
OFF: select RS485
3.5.3 DIP Switch for boot
Note: 1:off
0:on
Bit 4‐1
1111
1011
Description
Boot for SD/MMC
Boot for NAND
11/ 17
Single
Term
Bias‐
Bias+
Select RS232 or
RS485
FPA-C34, FPA-W34
3.5.6 LED
PWR LED: light indicate system power OK(main power up);off indicate system power turn off
Err LED: User can define by themself.
SS LED: User can define by themself.
TX LED: when UART1 send data, it can blink
RX LED: when UART1 receive data, it can blink
3.5.7 Micro SIM Card
Push the SIM Card, and Push again, it can put in or put out.
3.5.8 DEBUG
CONN, Pin header,1x4x2.0,TH, User can show the debug message and use keyboard
input debug command. It’s TTL level, we need a Uart‐debug board when we use it.
PIN1
Pin
Description
TTL_TXD
TTL_RXD
DGND
3.3V
3.5.9 Renew button
Renew button: long press this button will restore the factory setting, the long press time can be
setting by user
12/ 17
FPA-C34, FPA-W34
3.5.12 SD/MMC socket
This is standard SD card socket , user can save data on this storage.
13/ 17
FPA-C34, FPA-W34
4. Tips
Waste Disposal
It is recommended to disassemble the device before abandoning it in conformity
with local regulations. Please ensure that the abandoned batteries are disposed
according to local regulations on waste disposal. Do not throw batteries into fire
(explosive) or put in common waste canister. Products or product packages with the
sign of “explosive” should not be disposed like household waste but delivered to
specialized electrical&electronic waste recycling/disposal center. Proper disposal of
this sort of waste helps avoiding harm and adverse effect upon surroundings and
people’s health. Please contact local organizations or recycling/disposal center for
more recycling/disposal methods of related products.
Comply with the following safety tips:
Do not use in combustible and explosive environment
Keep away from combustible and explosive environment for fear of danger.
Keep away from all energized circuits.
Operators should not remove enclosure from the device. Only the group or person
with factory certification is permitted to open the enclosure to adjust and replace the
structure and components of the device. Do not change components unless the
power cord is removed. In some cases, the device may still have residual voltage even
if the power cord is removed. Therefore, it is a must to remove and fully discharge
the device before contact so as to avoid injury.
Unauthorized changes to this product or its components are prohibited.
In the aim of avoiding accidents as far as possible, it is not allowed to replace the
system or change components unless with permission and certification. Please
contact the technical department of Vantron or local branches for help.
Pay attention to caution signs.
Caution signs in this manual remind of possible danger. Please comply with
relevant safety tips below each sign. Meanwhile, you should strictly conform to all
safety tips for operation environment.
Notice
Considering that reasonable efforts have been made to assure accuracy of this
manual, Vantron assumes no responsibility of possible missing contents and
information, errors in contents, citations, examples, and source programs.
Vantron reserves the right to make necessary changes to this manual without prior
notice. No part of this manual may be reprinted or publicly released in for
FCC Warning
14/ 17
FPA-C34, FPA-W34
This device complies with FCC class B Rules. Operation is subject to the
Following conditions.
This device may not cause harmful interference.
This device must accept any interference received, including interference that may
cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
Any modification to the product is not permitted unless authorized by Vantron. It’s
not allowed to disassemble the product, it is not allowed to replace the system or
change components unless with permission and certification. Please contact the
technical support department of Vantron or local branches for help.
15/ 17
FPA-C34, FPA-W34
IC statement
This device complies with Industry Canada licence‐exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference, including interference that may cause
undesired operation of the device.
Warning! This class B digital apparatus complies with Canadian ICES‐003.
Industry Canada ICES‐003 Compliance Label:
CAN ICES‐3 (B)/NMB‐3(B)
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts.
L'exploitation est autorisée aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est
susceptible d'en compromettre le fonctionnement.
RF exposure warning
This equipment must be installed and operated in accordance with provide
instructions and the antenna used for this transmitter must be installed to provide a
separation distance of at least 20 cm from all persons and must not be co‐located or
operation in conjunction with any other antenna or transmitter. End‐users and
installers must be provide with antenna installation instructions and transmitter
operating conditions for satisfying RF exposure compliance.
16/ 17
FPA-C34, FPA-W34
US Office: Vantron Technology, Inc.
Address: 1292 Kifer Road #807,
Sunnyvale, CA 94086
Tel: 510-304-7666
Email: sales@vantrontech.com
China Office: Chengdu Vantron Technology, Ltd.
Address: 6th floor, 1st building, No.9, 3rd WuKe East Street, WuHou District,
Chengdu, P.R. China 610045
Tel: 86-28-8512-3930/3931, 8515-7572/6320
Email: sales@vantrontech.com.cn
US Office: Sierra Monitor Corporation
Address: 1991 Tarob Court, Milpitas CA 95035-6840, UNITED STATES
Tel: +1 408 964-4447
Fax: +1 408 262-9042
17/ 17

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V4.4 (128-bit)
User Access                     : Print, Extract, Print high-res
Author                          : x.fu
Create Date                     : 2016:08:16 17:35:55+08:00
Modify Date                     : 2016:08:25 11:12:34-07:00
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Format                          : application/pdf
Creator                         : x.fu
Title                           : Microsoft Word - User Manual_FPA-C34 and FPA-W34 V1.5 for FCC and IC 20160816A.docx
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2016:08:25 11:12:34-07:00
Producer                        : Acrobat Distiller 10.1.16 (Windows)
Document ID                     : uuid:3d9dee30-720d-40d6-9d98-07bec84c8ab1
Instance ID                     : uuid:a55c0bc7-aad5-49b3-8e4e-4625e11b1848
Page Count                      : 17
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AIVJ-FPAC34

Navigation menu