UNINTERRUPTIBLE POWER SUPPLY

MB1000

FOR YOUR HOME THEATER SYSTEM
MB1000
A Fully Programmable
UPS, Voltage Regulator
and Power Conditioner

FEATURES:

• Surge Protection and AVM

• Power Management Software

• LiFT Noise Filtration

• USB Interface

• Dual Learning IR Output
Controls

• Critical Load Management

• RS-232 with Open Source
Code Protocol

• RS232 Pin Cable Included

• Fully Programmable

www.panamax.com

• USB Cord Included
• Rack Mounting Kit

MB1000 FRONT/BACK PANELS FEATURES
Outlet Bank 1
Indicator
Illuminated blue
when outlet bank 1
is switched on.

Line Fault Indicator
This LED will illuminate in red to warn the user that a wiring
problem such as a bad/missing ground or reversed wiring exists
within the AC receptacle. If illuminated, disconnect all equipment
and contact an electrician to insure outlet is properly wired.

IR Detector
IR Detector, for
sampling IR remote
control signals.

Menu Navigation Knob
Rotate clockwise to navigate to the
next screen, counter-clockwise to
return to the previous screen, push
to select menu item.

Status Display
LCD displays status
and menu
navigation items.
Removable Battery
Access Panel
Easy to remove for
battery access and
replacement.

Power Switch
Press and hold the
power button for 2
seconds to turn the
UPS ON or OFF.
Outlet Bank 2
Indicator
Illuminated blue
when outlet bank 2
is switched on.

10 Ft. AC Power Cord
IR Control Section
Indicator LED’s –
Indicates status IR
Output Jacks – Standard
1/8” (3.5mm) mono jack
for connection to an IR
flasher (IR flashers not
included).

Circuit Breakers
Resettable circuit
breakers provide
optimal overload
protection.

USB to Computer
Outlet Bank 2 - Non-Critical-Load Outlets
Four battery powered, surge protected and AVR outlets
for connected equipment insures temporary uninterrupted operation of connected equipment during a power
failure. These outlets will shut off when the batteries
drain to a designated level to reserve remaining battery
charge from the critical load outlets.

Ground
Lug

Outlet Bank 1 - Critical Load Outlets
Four battery powered, surge protected
and AVR outlets for critical-load
equipment insures temporary
uninterrupted operation of connected
equipment during a power failure.

RS-232 Serial Communication Port
The serial port allows connection and communication between
the UPS and an automation or computer system. This allows
the installer to program a number of variables including the
Critical Load Battery Threshold. See the software documentation for more information.

MB1000 SPECIFICATIONS

MB1000 prevents critical equipment from losing setup configuration,

Input
Voltage
Frequency

via IR control to allow the projector bulbs to go through a proper
85 – 137 Vac
57 – 63 Hz

AC Power
Current Rating
Surge Protection
Overvoltage Shutoff, fast rise
Overvoltage Shutoff, slow rise
Undervoltage Shutoff
Automatic Voltage Regulation,
Sensitive Mode Capture Range
Automatic Voltage Regulation,
Sensitive Mode Output Range
Automatic Voltage Regulation,
Standard Mode Capture Range
Automatic Voltage Regulation,
Standard Mode Output Range
Filtration
40dB min from 100kHz-2MHz
65dB max @ 270kHz
UPS Output
Voltage
Frequency
UPS Output Capacity
UPS Backup Time
Transfer Time

stored data and hard-disk crashes. Shuts off projection equipment

12 A
900 Joules
150 ± 5 V
132 ± 5 V
90 ± 5 V

© 2009 Panamax Inc. Panamax and the Panamax logo are registered US trademarks of Panamax.

WEIGHTS & MEASUREMENTS, QUANTITIES, UPC’S
FOR ORDERING & SHIPPING
SINGLE MODEL MB1000

98 – 135 V

Dimensions
L 17” x H 4” x W 13”

120 ± 5%

SINGLE UNIT CARTON

93 – 145 V

Dimensions
L 22.25 x H 9.25” x W 17.5”

Weight
36 lbs.
Weight
40 lbs.

UPC
050616-008518

120 ± 10%

120 ± 5 V Simulated Sine Wave
60 Hz ± 1%
1000VA 600W @ 0.6pf
3 minutes at full load
< 10ms

Specifications subject to change due to product upgrades and improvements..

cool-down cycle before shutting off.

3 Year
Product
Warranty
2 Year Battery
Warranty

MODEL: MB1000
DESIGNED IN USA • MADE IN CHINA

C

US
LISTED

1690 Corporate Circle, Petaluma, CA. 94954 • 800-472-5555 • 707-283-5900
Fax 707-283-5901 • www.panamax.com