Pdf Ntp7 B Quick Install Guide 9901341_Rev E0_Universal_TP7_QSG_0217_PRINT User Manual N TP7

Pdf Ntp7-W Quick-Install-Guide pdf_nTP7-W_quick-install-guide pdf_nTP7-W_quick-install-guide nTP7-W products corebrands-resources

2017-06-28

User Manual: Manual Pdf Ntp7-B Quick-Install-Guide pdf_nTP7-B_quick-install-guide nTP7-B products

Open the PDF directly: View PDF PDF.
Page Count: 3

DownloadPdf Ntp7-B Quick-Install-Guide 9901341_Rev-E0_Universal_TP7_QSG_0217_PRINT User Manual N TP7-B
Open PDF In BrowserView PDF
Job: Universal Manual
Size: 150 x 150 mm folded
02/17/2015 -> Final print pdf

Folding-Method:

ELAN & Niles & SpeakerCraft

Quick Install Guide – TP7

8 pages each - Format: 150 x 300 mm ( Metric !! )

300

TP7 – 7” Touch Panel
User Interface
Quick Install Guide
English

Final Print pdf / Rev E
English only

150

150

150

150

Folded size:
150 x 150 mm
Open:
600 mm wide x 300 mm high
No bleed

02/17/2015 - TU
Questions?
Juergen 707 - 778 - 5826

+

P/N 9901341 REV. E0 02/2015
TP7 – 7” Touch Panel
User Interface
Quick Install Guide
English

9901341_Rev-E0_Universal_TP7_QSG_0217_PRINT.indd 1-4

2/17/15 1:54 PM

2

4

Powering up the TP7

Setting screen orientation

Important Safety Instructions

The TP7 will automatically power on when power is applied. Wait for the unit to boot up.

The TP7 is shipped pre-configured for landscape orientation.

- If connected to a wired Ethernet switch the TP7 will aquire a network address
via DHCP and automatically connect to the system.

To change orientation:

1. Read, understand and follow ALL safety and installation instructions included in this manual.
Failure to follow the included documentation may damage the product and will void manufacturer’s warranty.
2. Follow ALL installation guidelines included with the product. Installation of the product in high humidity environments,
in close proximity to heat sources and /or non-recommended locations WILL impede, interfere and/or damage
the intended operation of the product
3. Only use attachments and accessories which have been specified for use by the manufacturer.
4. The use of abrasive, liquid or solvent based cleaning fluids WILL damage the product.
Please refer and follow all Product Care instructions included with the product.
5. Product Servicing may ONLY be completed by authorized or certified service centers & personnel.
For a complete list of product servicing options, please follow instructions included in the product
documentation and /or contact original manufacturer for details.

– Press and hold power button for 3 seconds.
– Select Configure Panel from the popup menu.
– Select landscape or portrait orientation.

- If the TP7 does not detect a wired Ethernet connection and the WiFi radio has never been configured
you will be presented with the Network Configuration Utility interface. To complete the network
configuration please refer to the most current training documentation for your system.

Power

FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/ TV technician for help.

TP7 – 7” Touch Panel
User Interface
Quick Install Guide
English

3

5

Removing the TP7
– Using two hands grasp it on each side or the top and bottom and pull straight
out from the wall. It will require approx. 10lbs of force to remove it from the bracket.

RESET

FCC and IC Information:
This Class B digital apparatus complies with Part 15 of the FCC rules and with Canadian ICES-003 and RSS-210.

The recessed RESET button has two functions.
– Tap the button to reset the network configuration.
– Press and hold the button for 10 seconds to restore the TP7 to factory default configuration.

Mounting Bracket

Mounting Bracket
Top of 2 Gang Box

CAUTION:

Neither of these actions can be reversed.
Recessed
Reset Switch

Dry Wall

TP7 Frame

Operation is subject to the following two conditions:
1. This device may not cause interference and
2. This device must accept any interference, including interference that may cause undesired operation of the device.
Cet appareil numérique de classe B est conforme aux normes canadiennes ICES-003 et RSS-210. Son fonctionnement
est soumis aux deux conditions suivantes : (1) cet appareil ne doit pas causer d’interférence et (2) cet appareil doit
accepter toute interférence, notamment les interférences qui peuvent affecter son fonctionnement.
Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
FCC and IC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment and meets
the exemption from the routine evaluation limits in section 2.5 of RSS 102.

Recessed
Reset Switch

Thank you for including the TP7 as part of the user interface
strategy for your customer. The TP7 has been designed to
provide years of trouble free operation when wired and installed
properly. The TP7 has been designed for installation in low
humidity indoor environments and should never be installed
outdoors or in high humidity areas.
Included in the box
• 1ea TP7 touch panel
• 1ea TP7 mounting bracket
• 4ea Mounting screws
• 1ea DC power connector

Introduction
To install the TP7 you will also need a standard 2 gang
US junction box or low voltage bracket.

Paper Clip

Informations concernant l’exposition aux fréquences radio (RF):
La puissance de sortie émise par l’appareil de sans fil est inférieure à la limite `exposition aux fréquences radio d’Industry
Canada (IC). Utilisez l’appareil de sans fil de façon à minimiser les contacts humains lors du fonctionnement normal.
Ce périphérique a également été évalué et démontré conforme aux limites d’exposition aux RF d’IC dans des conditions
d’exposition à des appareils mobiles (antennes sont supérieures à 20 cm à partir du corps d’une personne).

Overall 8”w x 5”h
Mounting Depth 1 ¾”

Microphone

Dual Digital Beam Forming
Far Field Pickup

Speaker

2w integrated

Camera

640 x 480

Display

7”
800 x 480

Network

10/100 Ethernet
802.11 B/G/N WiFi

RJ-45
2 pin Phoenix
USB Type A
1/8” stereo (Future Use)

Power Requirements
Direct – 12V 1 A
PoE – IEEE 802.3at,
13w maximum draw
(@48 V 270 mA max)

Warning: The device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102,
and users can obtain Canadian information on RF exposure and compliance from the Canadian Representative
Product Solutions Group at Tel: (519) 763-4538.
© 2014 Core Brands, LLC. All rights reserved.
Core Brands, LLC, a Nortek company.

9901341_Rev-E0_Universal_TP7_QSG_0217_PRINT.indd 5-8

Dimensions

Connections
LAN/PoE
Power
USB
Audio Out

1. This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
2. This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with a minimum distance of 20 centimeters from user and bystanders.

LAN + Power
over Ethernet

Specifications

P/N 9901341 Rev. E0 02/2015
2/17/15 1:54 PM

TP7 – Overview

b. Rough-In

e. Installing the TP7 Bracket

12v Power Supply

The TP7 has been designed to mount to a US standard 2 gang box or low voltage bracket.

– The TP7 includes a mounting bracket that MUST be used. Using the included screws mount
the bracket onto the 2 gang box or low voltage bracket and verify that the bracket is level
before tightening the screws.

– By utilizing a 12v power supply (not included) to power the TP7 you may provide power
locally or remotely. If powering locally be sure to run the wire through the wall
in accordance with local codes. If powering remotely be sure to use wire of adequate
gauge for the length of the run.

Camera

Power

Microphone
Status LED

- The TP7 is “snap” fit into the box/bracket and requires approximately 10lbs of force
to remove it from the wall. Ensure that the mounting method you are using is compatible
with these requirements.

Proximity Sensor

– The mounting bracket is designed to level out uneven wall surfaces allowing the TP7 to fit
securely on most any surface. Note that uneven surfaces will create a gap between the back
of the panel and the wall – this is normal. Do not tighten the mounting bracket so as to
distort it’s shape as this will create issues with properly seating the TP7 in the bracket.

– Verify the polarity of your power supply prior to termination and ensure the power
supply is not connected to a power source.
– Strip approx. ¼” of insulation from the wire and observing the correct polarity, terminate
the wire into the supplied connector and tighten firmly. Be sure to twist the wires before
inserting so that no strands escape the connector. Inspect the termination to verify that
the wire is securely retained by the connector and no strands have escaped the barrier.

Speaker

– Plug the connector into the TP7.

F-2

Front of
Mounting Bracket

Old Work Box

New Const. Box

Back of TP7

Recessed
Reset Switch

TP7 Touch Panel

USB
Phoenix Type
Connector

Recessed
Reset Switch

DC Power
Input

Line in wall
LAN + Power
over Ethernet

Audio Out
(Future Use)

New Const. Low Volt Bracket

Old Work Low Volt Bracket

Planning the installation

c. Landscape Mounting

f. Connecting the TP7 to power

The TP7 is designed to wall mount in either Portrait or Landscape orientation.
Ensure there is adequate wall space for the TP7 and that the surface is relatively smooth.

– Install the 2 gang box or bracket in it’s normal orientation – with mounting screw holes
at the top and bottom. The box is exactly centered with the touch panel for your convenience.

– The TP7 is designed to be powered over the Ethernet connection (PoE) or by connecting
a 12v power supply (not included), but not both. If both the PoE and a 12v power supply
are connected the TP7 will draw power from the 12v source.

The TP7 requires a minimum mounting depth of 1 ¾” (4.5 cm) from the front surface
plus room for wire. Ensure that adequate depth is available.

Power
2 Gang Box

F-1-A

Power may be supplied by Power Over Ethernet (PoE) or by a 12v DC power supply (not included).
PoE must meet the IEEE 802.3af standard. Direct power via a 12v DC external power supply
requires a minimum current output of 1A.

TP7

The TP7 connects to the local network via Ethernet or Wi-Fi. When utilizing Wi-Fi you must
ensure that there is adequate Wi-Fi coverage at the mounting location.

1

PoE Connection
– PoE connection requires that IEEE 802.3af standard (13w maximum draw @48 V
is met. Utilize a network switch or PoE injector that meets this standard.

d. Portrait Mounting

a. Mounting height

– Install the 2 gang box or bracket rotated 90° - with the mounting screw holes on the left
and right sides. The box is exactly centered in the touch panel for your convenience.

To TP7

– Utilizing a T568A or T568B network cable connect to the LAN/PoE jack.
If you have terminated your own CAT 5e/6/7 cable use a tester to ensure that both
ends have been properly terminated.
h. Mounting the TP7
– The TP7 is held into the mounting bracket by spring steel tabs.
– Orient the TP7 with the POWER button at the top right for landscape mounting
or the top left for portrait mounting.
– To complete the installation simply grasp the TP7 on the edges and press firmly on to
the bracket until it is seatled.
when installing on to the mounting bracket. Press only on the frame edges.

F-1-B

PoE Injector

2 Gang Box

Mounting Bracket

Network Switch

165 cm / 65”
TP7

TP7 Touch Panel

PoE Network Switch

9901341_Rev-E0_Universal_TP7_QSG_0217_PRINT.indd 9-12

– When not utilizing PoE, but you have a physical network connection available it
is recommended that you connect the TP7 directly to the network switch.

CAUTION: DO NOT PRESS DIRECTLY ON THE SCREEN

Power

145 cm / 57”

@270 mA)

– Connect the TP7 using a standard T568A or T568B Ethernet cable from the network switch
to the LAN/PoE jack. If you have terminated your own CAT 5e/6/7 cable use a tester
to ensure that both ends have been properly terminated.

Installing the TP7

– Depending on how tall your homeowner is, it is recommended to locate the center
of TP 7 between 57”- 65” (145 cm -165 cm) above the finished floor.

g. Connecting Ethernet

Top of 2 Gang Box

Mounting Bracket

Dry Wall

TP7 Frame

2/17/15 1:54 PM



Navigation menu