Pdf Signal Line Protection Module Manual INS0769 REV. C User
Pdf Signal Line Protection Module Manual pdf_Signal_Line_Protection_Module_Manual pdf_Signal_Line_Protection_Module_Manual MOD-AT8110 products
Pdf Signal Line Protection Module Manual pdf_Signal_Line_Protection_Module_Manual pdf_Signal_Line_Protection_Module_Manual MOD-AT4 products
Pdf Signal Line Protection Module Manual pdf_Signal_Line_Protection_Module_Manual pdf_Signal_Line_Protection_Module_Manual MOD-AT2 products
Pdf Signal Line Protection Module Manual pdf_Signal_Line_Protection_Module_Manual pdf_Signal_Line_Protection_Module_Manual products
Panamax-Dataline-Surge-Suppressor-Modcat5-Modcat5-Users-Manual-516315 panamax-dataline-surge-suppressor-modcat5-modcat5-users-manual-516315
2017-11-03
User Manual: Manual Pdf Signal Line Protection Module Manual pdf_Signal_Line_Protection_Module_Manual MOD-CAT5 products
Open the PDF directly: View PDF .
Page Count: 2
Download | ![]() |
Open PDF In Browser | View PDF |
INSTRUCTIONS FOR PANAMAX SIGNAL LINE PROTECTION MODULES - PREMIUM SERIES 2 3 4 5 6 SAT / CATV MOD-DBSTV 4 5 6 8 MOD-SPKP DISCONTINUED PRODUCTS AC Base Units M8C-Pro LINE IN S110D LINE IN RJ-11 LINE IN Bracket Ground Connector Ground Connector MOD-AT4 For Analog Telephone Lines • 4 Pairs (8 wires) Protected • 260 Volt Clamping • Straight-Through Pinout • Incoming lines can be punched-down on the 110 jack on the LINE side and four RJ11 (single-line) cords will connect from the EQUIP side to the equipment. Caution: Never install telephones during a lightning storm. • Four RJ11 (single-line) cords connected to the LINE side can be combined into a single RJ45 (8 wire) cord (upper jack) on the EQUIP side. Model: MOD-AT8110 (Secondary Protector) AC Base Unit WIRING DIAGRAM AND SPECIFICATIONS Blue Blue Orange Pull Out It is very important to connect telephone signal lines properly. An easy access PULL OUT card is included on the back of each module for wiring diagrams and specifications. 800-472-5555 www.panamax.com Pull Out SAT / CATV EQUIP OUT RJ-11 EQUIP OUT RJ-11 • Two RJ14 (dual-line) cords connected to the LINE side (upper 2 jacks) can be split to four RJ11 (single-line) cords on the EQUIP side. EQUIP. OUT There are no designated input/output connections on coaxial protection modules. These are bi-directional modules in both transmission frequency and voltage. EQUIP OUT S110D The MOD-AT4 module is designed to protect standard phone lines and DSL (ADSL, G.Lite) lines. Multiple input & output jacks provide complete installation flexibility. The following diagram shows how the jacks/wires are interconnected. Different cables/connections can be split or combined to accommodate a variety of installations. For example: LINE IN S110D MOD-AT8110 All telephone input/output connections will be labeled with LINE and EQUIP. Pull Out Card 2. Mount the signal line module to the bracket (screws provided with the module). Br 1-4 Installation Instructions Ground Connector Gr Br 1-4 LINE IN RJ-11 EQUIP OUT RJ-14 Gr 1-4 When properly installed, the base unit’s Connected Equipment Protection Policy remains valid. All modules include a small rectangular bracket and mounting screws. This bracket replaces the small triangular wall-mount bracket that comes with the models listed in the CURRENT PRODUCTS above. Module LINE IN RJ-14 Bl Or 1-8 PM8DBS-EX M8C-EX M8HC-Pro EQUIP OUT RJ-45 1-8 M8-EX LINE IN RJ-45 Bl Or 1-4 PM8C-EX M8KSU M8COM M8KSU 1-4 PM8-HT M8 M8T M8C 1-4 M4T-EX M8DBS-EX M4 M4T M4L MOD-AT4 PM8T-EX 4. Connect the wiring to the signal line module as shown in the appropriate following section. 2. Use a modular cord to connect the EQUIP modular jack to the equipment to be protected. Model: MOD-AT4 (Secondary Protector) Pull Out M8-HT 3. Optional – The assembled base unit and module(s) may be wall mounted if desired. 1. Connect the telephone line to the LINE jack on the module. WIRING DIAGRAM AND SPECIFICATIONS M8C-EX 1. Mount the rectangular bracket to the back of the AC base unit with the #8-32 x 5/16” machine screws. Note: The brass ground connector must be used with the bracket in order to bond the module ground to the base unit’s ground. 1-8 MOD-DT4 7 8 AC Base Units M4-EX • 4 Wires (1 RJ-14) Protected • 260 Volt Clamping • Auto-resetting PTC's The MOD-AT2 module is designed to protect standard phone lines connected to computer modems, telephones, pay-per-view ports, etc. It will also protect DSL lines (ADSL, G.Lite) going into the DSL modem. The MOD-AT2 module will protect a single phone line using an RJ-11 (2 wire) cord or a dual phone line using an RJ-14 (4 wire) cord. 3 7 CURRENT PRODUCTS PM8-EX MOD-AT2 For Analog Telephone Lines EQUIP OUT 2 These modules are approved accessories for use with compatible Panamax AC base units. Compatible base units include the following: M8HT-PRO LINE IN 1 1 OUTSIDE LINES MOD-UTP MOD-CAT5 MOD-CAT5 LINE IN RJ-11 EQUIP OUT RJ-11 WIRING DIAGRAM AND SPECIFICATIONS EQUIP OUT RJ-11 EQUIP OUT RJ-11 MOD-DT4 Pull Out SAT / CATV EQUIP OUT S110D MOD-AT2 MOD-AT8110 Pull Out Card Pull Out Pull Out MOD-UTP LINE IN RJ-11 Model: MOD-AT2 (Secondary Protector) EQUIP OUT RJ-14 1-8 MOD-AT4 EQUIP. OUT LINE IN S110D LINE IN RJ-11 SAT / CATV LINE IN EQUIP OUT S110D EQUIP OUT RJ-45 RECEIVER EQUIP OUT RJ-11 EQUIP OUT RJ-11 MOD-AT8110 LINE IN S110D LINE IN RJ-14 Pull Out MOD-AT2 EQUIP OUT S110D LINE IN RJ-45 MOD-SPKP LINE IN RJ-11 EQUIP OUT RJ-14 MOD-DBSTV LINE IN RJ-11 EQUIP OUT MOD-AT4 MOD-AT2 LINE IN S110D EQUIP OUT RJ-45 Pull Out Pull Out LINE IN LINE IN RJ-14 Pull Out Pull Out LINE IN RJ-45 EQUIP OUT S110D Orange Green Green Brown Brown Blue Blue Orange Orange Green Green Brown Brown 110 IDC L I MOD-AT8110 110 IDC For Analog Telephone Lines • 16 Wires (two 110 punch-downs) Protected • 260 Volt Clamping • Auto-resetting PTC's The MOD-AT8110 module is designed to protect up to 8 standard phone lines using 110 punchdown connectors on both the input LINE and output EQUIP. 1. Cut the cable from the primary protector to the correct length and punch down the 1 cable to the LINE IN punchdown block on the module. 2. Punch down another cable to the EQUIP OUT punchdown block on the module and connect to the phone equipment. INSTRUCTIONS FOR PANAMAX SIGNAL LINE PROTECTION MODULES - PREMIUM SERIES Model: MOD-DT4 (Secondary Protector) Model: MOD-DBSTV (Secondary Protector) WIRING DIAGRAM AND SPECIFICATIONS 1-4 For Digital Telephone Lines • 4 Pairs (8 wires) Protected • 70 Volt Clamping • Straight-Through Pinout For example: • Station Set lines from the phone system can be punched-down on the 110 jack on the EQUIP side and four RJ11 (2 wire) cords will connect from the LINE side to the Station Sets. SAT / CATV SAT 2 1. Connect the Satellite LNB or Cable TV coax cable from the wall/floor jack to one of the “F” connectors labled SAT/CATV on the module • Station Set lines from the phone system can be punched-down on the 110 jack on the EQUIP side and two RJ14 (4 wire) cords will connect from the LINE side (upper 2 jacks) to the Station Sets. LINE EQUIP MOD-DBSTV For Digital Satellite & CATV Systems 3 Sat/CATV Lines Protected 75 Volt Clamping <1 0.5dB 0 MHz to 2.2 GHz 1 Phone Line Protected 260 Volt Clamping RJ-11 CATV Note: This reminder is provided to call the CATV installer’s attention to Article 820-40 of the NEC that provides guidelines for proper grounding and, in particular, specifies that the cable ground shall be connected to the grounding system of the building as close to the point of entry as possible. 2. Use a coax patch cord to connect the other SAT/CATV labeled modular “F” connector to the equipment to be protected. Caution: Never install telephones during a lightning storm. 3. Repeat steps 1 and 2 for up to 2 additional satellite or cable TV lines. 4.Connect the telephone line to the LINE jack on the module. 5. Use a modular cord to connect the EQUIP modular jack to the equipment to be protected. WIRING DIAGRAM AND SPECIFICATIONS MOD-UTP For 10/100 Base-T Ethernet 1- 8 EQUIP. OUT 1-8 Pull Out MOD-UTP SAT 1 The MOD-DBSTV module provides protection for 3 SAT / CABLE / ANT and 1 telephone line. Model: MOD-UTP (Isolated Loop Circuit Protector) LINE IN EQUIP OUT RJ-11 1-4 MOD-DT4 Coax protectors are bi-directional. There is no "IN" or "OUT". LINE IN RJ-11 1-4 SAT / CATV 1-4 The MOD-DT4 module is designed to protect Digital Station (DS) Set phone lines. Station Set lines that leave the building are a pathway for surges (backdoor) to enter the phone system. This is why the lines FROM the Station Sets are connected to the LINE side of the module and the EQUIP side of the module is connected to the phone system. Multiple input & output jacks provide complete installation flexibility. The following diagram shows how the jacks/wires are interconnected. Different cables/connections can be split or combined to accommodate a variety of installations. SAT / CATV MOD-DBSTV Br PINS 3, 4 1-8 Br 1-4 LINE IN RJ-11 EQUIP OUT RJ-11 EQUIP OUT RJ-11 Gr 1-4 LINE IN RJ-11 EQUIP OUT S110D Gr WIRING DIAGRAM AND SPECIFICATIONS Pull Out Card LINE IN S110D EQUIP OUT RJ-14 Bl Or 1-8 LINE IN RJ-14 EQUIP OUT RJ-45 MOD-DT4 Pull Out LINE IN RJ-45 Bl Or Model: MOD-SPKP (Isolated Loop Circuit Protector) • 4 Wires (Pins 1, 2, 3, 6) Protected • 7 Volt Clamping WIRING DIAGRAM AND SPECIFICATIONS Please note: The protection circuitry will not work if the signal lines are reversed. 5 6 3 4 5 6 7 7 8 8 The MOD-SPKP module is designed to protect outdoor speaker, keypad, control and security wires (8 wires or 4 pairs). Equipment lines that lead outside the building are pathways for surges (sometimes called backdoor surges) to enter the equipment. This is why the lines FROM the outdoor equipment is connected to the LINE side of the module and the EQUIP side of the module is connected to the equipment. SPECIFICATIONS Pull Out MOD-CAT5 4 2 RECEIVER 3 MOD-SPKP 2 Model: MOD-CAT5 (Isolated Loop Circuit Protector) The MOD-CAT5 module is designed for high-speed data applications-networks including CAT 5, fast Ethernet, ATM, and other high-speed active transport devices. 1 1 OUTSIDE LINES 1. Connect the network line from wall/floor jack to the LINE jack on the module. 2. Use a modular cord to connect the EQUIP modular jack to the equipment to be protected. Pull Out The MOD-UTP module is designed to protect networked computer equipment. It will protect one Ethernet 10/100 Base-T, Token Ring, Arcnet, or AppleTalk network line. Use modules bonding-strap connection to attach ground, shield or drain wires. MOD-CAT5 For 10/100/1000 Base-T Ethernet • 8 Wires (4 Pairs) Protected • 19 Volt Clamping • CAT5E Compliant 1. Connect the CAT 5 cable connected on either side on the module to the wall/floor jack and then to the equipment to be protected. There is no “IN” or “OUT”. MOD-CAT5 is bi-directional. 1. Strip the ends of the individual wires about 1/4 inch. The screw clamp terminals will work with a range of wire sizes (up to 12AWG). Spade lugs are not required, but may be used. 2 MOD-SPKP For Outdoor Speaker, Keypad, Control & Security Wires • 8 Wires Protected, 47 Volt Clamping • 7 Amp (per wire) Capacity, • 12 AWG Max. Wire Size 2. Connect the wires from the outdoor equipment to terminals on the LINE side of the module. 3. Connect the wires from the EQUIP side of the module to the equipment. 4. If the cable has a shield or drain wire, connect it to the modules bonding-strap connection located on the upper right portion of the module. If more than one module is connected to the AC base unit, placing this module at the top may allow for easier connection of shield or drain wires. INS0769 REV .D 06/07
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Create Date : 2007:06:28 10:37:00-07:00 Creator : QuarkXPress(tm) 6.0 Modify Date : 2007:06:28 10:57:23-07:00 Producer : Acrobat Distiller 7.0.5 for Macintosh Creation Date : 2007:06:28 10:37:00-07:00 Mod Date : 2007:06:28 10:57:23-07:00 Creator Tool : QuarkXPress(tm) 6.0 Metadata Date : 2007:06:28 10:57:23-07:00 Document ID : uuid:2e260516-259e-11dc-bbfa-000a95d577c6 Instance ID : uuid:2e2608ea-259e-11dc-bbfa-000a95d577c6 Format : application/pdf Title : INS0769 REV. C (Page 1) Page Count : 2EXIF Metadata provided by EXIF.tools