Pdf Signal Line Protection Module Manual INS0769 REV. C User

Pdf Signal Line Protection Module Manual pdf_Signal_Line_Protection_Module_Manual pdf_Signal_Line_Protection_Module_Manual MOD-AT8110 products

Pdf Signal Line Protection Module Manual pdf_Signal_Line_Protection_Module_Manual pdf_Signal_Line_Protection_Module_Manual MOD-AT4 products

Pdf Signal Line Protection Module Manual pdf_Signal_Line_Protection_Module_Manual pdf_Signal_Line_Protection_Module_Manual MOD-AT2 products

Pdf Signal Line Protection Module Manual pdf_Signal_Line_Protection_Module_Manual pdf_Signal_Line_Protection_Module_Manual products

Panamax-Dataline-Surge-Suppressor-Modcat5-Modcat5-Users-Manual-516315 panamax-dataline-surge-suppressor-modcat5-modcat5-users-manual-516315

2017-11-03

User Manual: Manual Pdf Signal Line Protection Module Manual pdf_Signal_Line_Protection_Module_Manual MOD-CAT5 products

Open the PDF directly: View PDF PDF.
Page Count: 2

DownloadPdf Signal Line Protection Module Manual INS0769 REV. C  User
Open PDF In BrowserView PDF
INSTRUCTIONS FOR PANAMAX SIGNAL LINE PROTECTION MODULES - PREMIUM SERIES

2
3
4
5
6

SAT /
CATV

MOD-DBSTV

4
5
6

8

MOD-SPKP

DISCONTINUED PRODUCTS
AC Base Units

M8C-Pro

LINE
IN
S110D

LINE
IN
RJ-11

LINE
IN

Bracket
Ground
Connector

Ground
Connector

MOD-AT4
For Analog
Telephone
Lines
• 4 Pairs (8 wires) Protected
• 260 Volt Clamping • Straight-Through Pinout

• Incoming lines can be punched-down on
the 110 jack on the LINE side and four RJ11
(single-line) cords will connect from the
EQUIP side to the equipment.

Caution: Never install telephones
during a lightning storm.

• Four RJ11 (single-line) cords connected
to the LINE side can be combined into a
single RJ45 (8 wire) cord (upper jack) on the
EQUIP side.

Model: MOD-AT8110 (Secondary Protector)
AC Base Unit

WIRING DIAGRAM AND SPECIFICATIONS
Blue

Blue

Orange

Pull Out

It is very important to connect
telephone signal lines properly.
An easy access
PULL OUT card
is included on
the back of each
module for wiring
diagrams and
specifications.

800-472-5555 www.panamax.com

Pull Out

SAT /
CATV

EQUIP
OUT
RJ-11
EQUIP
OUT
RJ-11

• Two RJ14 (dual-line) cords connected to
the LINE side (upper 2 jacks) can be split to
four RJ11 (single-line) cords on the EQUIP
side.

EQUIP.
OUT

There are no designated
input/output connections
on coaxial protection
modules. These are
bi-directional modules
in both transmission frequency and voltage.

EQUIP
OUT
S110D

The MOD-AT4 module is designed to protect standard phone lines and DSL (ADSL,
G.Lite) lines. Multiple input & output jacks
provide complete installation flexibility. The
following diagram shows how the
jacks/wires are interconnected. Different
cables/connections can be split or combined to accommodate a variety of installations. For example:

LINE
IN
S110D

MOD-AT8110

All telephone input/output connections will
be labeled with LINE and EQUIP.

Pull Out Card

2. Mount the signal line module to the
bracket (screws provided with the module).

Br

1-4

Installation Instructions

Ground
Connector

Gr

Br

1-4

LINE
IN
RJ-11

EQUIP
OUT
RJ-14

Gr

1-4

When properly installed, the base unit’s Connected Equipment Protection Policy
remains valid. All modules include a small rectangular bracket and mounting screws. This
bracket replaces the small triangular wall-mount bracket that comes with the models listed in
the CURRENT PRODUCTS above.

Module

LINE
IN
RJ-14

Bl
Or

1-8

PM8DBS-EX M8C-EX M8HC-Pro

EQUIP
OUT
RJ-45

1-8

M8-EX

LINE
IN
RJ-45

Bl
Or

1-4

PM8C-EX

M8KSU
M8COM
M8KSU

1-4

PM8-HT

M8
M8T
M8C

1-4

M4T-EX M8DBS-EX

M4
M4T
M4L

MOD-AT4

PM8T-EX

4. Connect the wiring to the signal line
module as shown in the appropriate following section.

2. Use a modular cord to connect the
EQUIP modular jack to the equipment to be
protected.

Model: MOD-AT4 (Secondary Protector)

Pull Out

M8-HT

3. Optional – The assembled base unit and
module(s) may be wall mounted if desired.

1. Connect the telephone line to the LINE
jack on the module.

WIRING DIAGRAM AND SPECIFICATIONS

M8C-EX

1. Mount the rectangular bracket to the back
of the AC base unit with the #8-32 x 5/16”
machine screws.
Note: The brass ground connector must be
used with the bracket in order to bond the
module ground to the base unit’s ground.

1-8

MOD-DT4

7

8

AC Base Units
M4-EX

• 4 Wires (1 RJ-14) Protected
• 260 Volt Clamping
• Auto-resetting PTC's

The MOD-AT2 module is designed to protect
standard phone lines connected to computer
modems, telephones, pay-per-view ports, etc.
It will also protect DSL lines (ADSL, G.Lite)
going into the DSL modem. The MOD-AT2
module will protect a single phone line using
an RJ-11 (2 wire) cord or a dual phone line
using an RJ-14 (4 wire) cord.

3

7

CURRENT PRODUCTS
PM8-EX

MOD-AT2
For Analog Telephone Lines
EQUIP
OUT

2

These modules are approved accessories for use with compatible Panamax AC
base units. Compatible base units include the following:

M8HT-PRO

LINE
IN

1

1

OUTSIDE LINES

MOD-UTP

MOD-CAT5

MOD-CAT5

LINE
IN
RJ-11
EQUIP
OUT
RJ-11

WIRING DIAGRAM AND SPECIFICATIONS

EQUIP
OUT
RJ-11
EQUIP
OUT
RJ-11

MOD-DT4

Pull Out

SAT /
CATV

EQUIP
OUT
S110D

MOD-AT2

MOD-AT8110

Pull Out
Card

Pull Out

Pull Out

MOD-UTP

LINE
IN
RJ-11

Model: MOD-AT2 (Secondary Protector)

EQUIP
OUT
RJ-14

1-8

MOD-AT4

EQUIP.
OUT

LINE
IN
S110D

LINE
IN
RJ-11

SAT /
CATV

LINE
IN

EQUIP
OUT
S110D

EQUIP
OUT
RJ-45

RECEIVER

EQUIP
OUT
RJ-11
EQUIP
OUT
RJ-11

MOD-AT8110

LINE
IN
S110D

LINE
IN
RJ-14

Pull Out

MOD-AT2

EQUIP
OUT
S110D

LINE
IN
RJ-45

MOD-SPKP

LINE
IN
RJ-11

EQUIP
OUT
RJ-14

MOD-DBSTV

LINE
IN
RJ-11

EQUIP
OUT

MOD-AT4

MOD-AT2

LINE
IN
S110D

EQUIP
OUT
RJ-45

Pull Out

Pull Out

LINE
IN

LINE
IN
RJ-14

Pull Out

Pull Out

LINE
IN
RJ-45

EQUIP
OUT
S110D

Orange

Green

Green

Brown

Brown

Blue

Blue

Orange

Orange

Green

Green

Brown

Brown
110
IDC

L
I

MOD-AT8110

110
IDC

For Analog Telephone Lines
• 16 Wires (two 110 punch-downs) Protected
• 260 Volt Clamping
• Auto-resetting PTC's

The MOD-AT8110 module is designed to
protect up to 8 standard phone lines using
110 punchdown connectors on both the
input LINE and output EQUIP.
1. Cut the cable from the primary protector
to the correct length and punch down the

1

cable to the LINE IN punchdown block on
the module.
2. Punch down another cable to the EQUIP
OUT punchdown block on the module and
connect to the phone equipment.

INSTRUCTIONS FOR PANAMAX SIGNAL LINE PROTECTION MODULES - PREMIUM SERIES
Model: MOD-DT4 (Secondary Protector)

Model: MOD-DBSTV (Secondary Protector)

WIRING DIAGRAM AND SPECIFICATIONS

1-4

For Digital
Telephone Lines
• 4 Pairs (8 wires) Protected
• 70 Volt Clamping • Straight-Through Pinout

For example:
• Station Set lines from the phone system
can be punched-down on the 110 jack on
the EQUIP side and four RJ11 (2 wire)
cords will connect from the LINE side to the
Station Sets.

SAT /
CATV

SAT 2

1. Connect the Satellite LNB or Cable TV
coax cable from the wall/floor jack to one of
the “F” connectors labled SAT/CATV on the
module

• Station Set lines from the phone system
can be punched-down on the 110 jack on
the EQUIP side and two RJ14 (4 wire) cords
will connect from the LINE side (upper 2
jacks) to the Station Sets.

LINE
EQUIP

MOD-DBSTV
For Digital Satellite & CATV Systems
3 Sat/CATV Lines Protected
75 Volt Clamping
<1 0.5dB 0 MHz to 2.2 GHz
1 Phone Line Protected
260 Volt Clamping

RJ-11

CATV

Note: This reminder is provided to call the
CATV installer’s attention to Article 820-40
of the NEC that provides guidelines for
proper grounding and, in particular, specifies that the cable ground shall be connected to the grounding system of the building
as close to the point of entry as possible.

2. Use a coax patch cord to connect the
other SAT/CATV labeled modular “F” connector to the equipment to be protected.

Caution: Never install telephones
during a lightning storm.

3. Repeat steps 1 and 2 for up to 2 additional satellite or cable TV lines.
4.Connect the telephone line to the LINE
jack on the module.
5. Use a modular cord to connect the
EQUIP modular jack to the equipment to be
protected.

WIRING DIAGRAM AND SPECIFICATIONS

MOD-UTP
For 10/100 Base-T Ethernet
1- 8

EQUIP.
OUT

1-8

Pull Out

MOD-UTP

SAT 1

The MOD-DBSTV module provides protection for 3 SAT / CABLE / ANT and 1 telephone line.

Model: MOD-UTP (Isolated Loop Circuit Protector)

LINE
IN

EQUIP
OUT
RJ-11

1-4

MOD-DT4

Coax protectors are bi-directional.
There is no "IN" or "OUT".

LINE
IN
RJ-11

1-4

SAT /
CATV

1-4

The MOD-DT4 module is designed to protect Digital Station (DS) Set phone lines.
Station Set lines that leave the building are a
pathway for surges (backdoor) to enter the
phone system. This is why the lines FROM
the Station Sets are connected to the LINE
side of the module and the EQUIP side of
the module is connected to the phone system. Multiple input & output jacks provide
complete installation flexibility. The following diagram shows how the jacks/wires are
interconnected. Different cables/connections can be split or combined to accommodate a variety of installations.

SAT /
CATV

MOD-DBSTV

Br

PINS 3, 4

1-8

Br

1-4

LINE
IN
RJ-11

EQUIP
OUT
RJ-11
EQUIP
OUT
RJ-11

Gr

1-4

LINE
IN
RJ-11

EQUIP
OUT
S110D

Gr

WIRING DIAGRAM AND SPECIFICATIONS

Pull Out
Card

LINE
IN
S110D

EQUIP
OUT
RJ-14

Bl
Or

1-8

LINE
IN
RJ-14

EQUIP
OUT
RJ-45

MOD-DT4

Pull Out

LINE
IN
RJ-45

Bl
Or

Model: MOD-SPKP (Isolated Loop Circuit Protector)

• 4 Wires (Pins 1, 2, 3, 6) Protected
• 7 Volt Clamping

WIRING DIAGRAM AND SPECIFICATIONS

Please note: The protection circuitry
will not work if the signal lines are
reversed.

5
6

3
4
5
6

7

7

8

8

The MOD-SPKP module is designed to
protect outdoor speaker, keypad, control and
security wires (8 wires or 4 pairs).
Equipment lines that lead outside the building are pathways for surges (sometimes
called backdoor surges) to enter the equipment. This is why the lines FROM the outdoor equipment is connected to the LINE
side of the module and the EQUIP side of
the module is connected to the equipment.

SPECIFICATIONS
Pull Out

MOD-CAT5

4

2

RECEIVER

3

MOD-SPKP

2

Model: MOD-CAT5 (Isolated Loop Circuit Protector)

The MOD-CAT5 module is designed for
high-speed data applications-networks
including CAT 5, fast Ethernet, ATM, and
other high-speed active transport devices.

1

1

OUTSIDE LINES

1. Connect the network line from wall/floor
jack to the LINE jack on the module.

2. Use a modular cord to connect the
EQUIP modular jack to the equipment to be
protected.
Pull Out

The MOD-UTP module is designed to protect networked computer equipment. It will
protect one Ethernet 10/100 Base-T, Token
Ring, Arcnet, or AppleTalk network line.

Use modules bonding-strap connection
to attach ground, shield or drain wires.

MOD-CAT5
For 10/100/1000 Base-T Ethernet
• 8 Wires (4 Pairs) Protected
• 19 Volt Clamping
• CAT5E Compliant

1. Connect the CAT 5 cable connected on
either side on the module to the wall/floor
jack and then to the equipment to be protected. There is no “IN” or “OUT”. MOD-CAT5 is
bi-directional.

1. Strip the ends of the individual wires
about 1/4 inch. The screw clamp terminals
will work with a range of wire sizes (up to
12AWG). Spade lugs are not required, but
may be used.

2

MOD-SPKP
For Outdoor Speaker, Keypad, Control & Security Wires
• 8 Wires Protected, 47 Volt Clamping
• 7 Amp (per wire) Capacity,
• 12 AWG Max. Wire Size

2. Connect the wires from the outdoor
equipment to terminals on the LINE side of
the module.
3. Connect the wires from the EQUIP side
of the module to the equipment.
4. If the cable has a shield or drain wire,
connect it to the modules bonding-strap
connection located on the upper right portion of the module. If more than one module is connected to the AC base unit, placing
this module at the top may allow for easier
connection of shield or drain wires.

INS0769 REV .D

06/07



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Create Date                     : 2007:06:28 10:37:00-07:00
Creator                         : QuarkXPress(tm) 6.0
Modify Date                     : 2007:06:28 10:57:23-07:00
Producer                        : Acrobat Distiller 7.0.5 for Macintosh
Creation Date                   : 2007:06:28 10:37:00-07:00
Mod Date                        : 2007:06:28 10:57:23-07:00
Creator Tool                    : QuarkXPress(tm) 6.0
Metadata Date                   : 2007:06:28 10:57:23-07:00
Document ID                     : uuid:2e260516-259e-11dc-bbfa-000a95d577c6
Instance ID                     : uuid:2e2608ea-259e-11dc-bbfa-000a95d577c6
Format                          : application/pdf
Title                           : INS0769 REV. C (Page 1)
Page Count                      : 2
EXIF Metadata provided by EXIF.tools

Navigation menu