File #E37116 Electric Baseboard Heaters 1800, 2500, C1800 & C2500 Series Installation & Maintenance Instructions Dear Owner, Congratulations! Thank you for purchasing this new heater manufactured by a division of Marley Engineered Products. You have made a wise investment selecting the highest quality product in the heating industry. Please carefully read the installation and maintenance instructions shown in this manual. You should enjoy years of efficient heating comfort with this product from Marley Engineered Products... the industry’s leader in design, manufacturing, quality and service. ... The Employees of Marley Engineered Products ! WARNING 4. 5. Do not recess heater in wall. The installation must comply with applicable Local and National Electrical Codes and utility requirements. 6. Do not remove or by-pass thermal cutout. 7. To reduce the risk of fire, do not store or use gasoline or other flammable vapors and liquids in the vicinity of the heater. 8. Personal injury or death could result from electric shock. Disconnect all power to heater at main panel before attempting to install or service this heater. 9. Supply voltage must be the same as heater voltage. Check heater nameplate and supply voltage before energizing. 10. When using RSA Transformer Relay Accessory, supply wiring must be suitable for 90°C. Read Carefully - This Instruction Sheet contains vital information for the proper installation, use, and efficient operation of the heater. Carefully read the manual before installation, operation, or cleaning of the heater. Failure to adhere to the instructions could result in fire, electric shock, death, serious personal injury, or property damage. Save these instructions and review frequently for continuing safe operation and instructing future users. 1. 2. 3. Keep all electrical cords, foam filled articles, drapes, bedding, and other household furnishings away from contact with heater. It is recommended all items be kept a minimum of six (6") inches (152mm) from heater. Do not install baseboard heater below electrical convenience receptacles (outlets). Do not install baseboard heater against vinyl wallpaper, paperboard or low density fiberboard surface. Do not install vinyl drapes or vinyl blinds above heater. 1 pole thermostat accessory is available for installation into this heater at your place of purchase, or the heater may be connected to any suitable wall mounted thermostat that will meet the electrical load requirements. Installation or use of this product in any manner not described herein will void the warranty and could result in injury, damage to property, or permanent damage to heater. Heater Ampere Rating. 208 Volt 240 Volt 277 Volt 347 Volt 600 Volt Residential Model No. Commercial Model No. 120 Volt 2512 * 25126 * 2513 * 2514 * 2515 * 2516 * C25126 * C2513 * C2514 * C2515 * C2516 * 3.3 4.2 6.3 8.3 10.4 12.5 - - - - - 2502 * 25026 * 2503 * 2504 * 2505 * 2506 * 2507 * 2508 * 25008 * C25026 * C2503 * C2504 * C2505 * C2506 * C2507 * C2508 * C25008 * - 1.9 2.4 3.6 4.8 6.0 7.2 9.6 8.4 12.0 - - - - 2542 * 25426 * 2543 * 2544 * 2545 * 2546 * 2547 * 2548 * 25408 * C25426 * C2543 * C2544 * C2545 * C2546 * C2547 * C2548 * C25408 * - 1.4 1.8 2.7 3.6 4.5 5.4 6.3 7.2 8.7 1.7 2.1 3.1 4.2 5.2 6.3 7.3 8.3 10.4 - - - 2572 * 25726 * 2573 * 2574 * 2575 * 2576 * 2577 * 2578 * 25708 * C25726 * C2573 * C2574 * C2575 * C2576 * C2577 * C2578 * C25708 * - 1.1 1.4 2.0 2.7 3.4 4.1 4.7 5.4 6.8 1.2 1.6 2.4 3.1 3.9 4.7 5.5 6.3 7.5 1.4 1.8 2.7 3.6 4.5 5.4 6.3 7.2 9.0 - - 25326 * 2533 * 2534 * 2535 * 2536 * 2537 * 2538 * 25308 * 2530 * C25326 * C2533 * C2534 * C2535 * C2536 * C2537 * C2538 * C25308 * C2530 * - - - - 1.4 2.2 2.9 3.6 4.3 5.0 5.8 7.2 7.2 - 2564 * 2565 * 2566 * 2567 * 2568 * 25608 * 2560 * C2564 * C2565 * C2566 * C2567 * C2568 * C25608 * C2560 * - - - - - 1.7 2.1 2.5 2.9 3.3 4.2 4.2 UNPACKING HEATER Check heater to make sure it has not been damaged in shipping. Do not install or attempt to operate the heater if damaged. Return to place of purchase or file claim with freight carrier. NOTICE TO OWNERS Certain fabrics discolor in time from indirect sunlight and normal room temperature - mostly organic and synthetic material. They will discolor more rapidly when exposed to direct sunlight and warm currents. Hang drapes to provide minimum of 2 in.(51mm) air space between heater front and nearest drape fold as shown in Example 1 Figure 1, or 6 in.(153mm) airspace between top of heater and bottom of drapes as shown in Example 2, Figure 1. Allow minimum clearance of 1 in. (26mm) from drapes to ceiling and to top of floor covering to permit air circulation as shown in Example 1, Figure 1. * Followed by WC or NWC suffix Total Amps 0 thru 12 12.1 thru 16 16.1 thru 24 Minimum AWG. Wire Size (Copper) #14 #12 #10 Circuit Breaker or Fuse Size 15 amp 20 amp 30 amp Figure. 1 Position Drapery near Heater INSTALLATION FLOORS & CARPETING: Heaters may be mounted directly on any floor surface, including carpeting. Where wall-to-wall carpets are installed after the baseboard installation, the carpeting can be run up to the front and around the heater body, providing it does not obstruct air flow. (Maximum 3/4” (19mm) thick). 1. Remove wiring compartment cover at end of heater where power supply cable is to enter. Determine desired mounting location (Figure 2), position heater to wall as intended and mark wall (or floor) at location where power supply is to enter heater. NET VOLUMES OF WIRING COMPARTMENT CUBIC INCHES CUBIC CENTIMETERS Heater Only (Each Wiring Compartment) 14.96 241 Heater W/SP Thermostat 11.18 180 Heater W/DP Thermostat 11.18 180 Heater W/Heat-Cool Switch Receptacle 9.51 153 Heater W/Duplex Receptacle 11.18 180 Heater W/DP Disconnect Switch 11.18 180 Heater W/Power Relay 10.76 174 Heater W/Transformer Relay 2.93 47 DESCRIPTION This Heater is designed to provide years of efficient, trouble free operation as a primary or supplementary heat source for residential and commercial applications. Baseboard heaters must be thermostatically controlled for efficient, safe operation. A thermostat is not provided with this heater. However, a single or double Figure. 2 2 NOTE: Make sure the caution label with the word “TOP” is at the top of the heater. For most efficient operation locate heaters along outside wall under windows. Position heater so it can be secured to wall stud. Power cable must enter heater through one of the knockouts provided in wiring compartment. See Figure 3. ! CAUTION When using bottom mounting holes, (to prevent a possible shock or fire hazard,) make sure you do not drive the screws through or damage the power supply wire. 7. 6.75 (153,2) 8. Connect the supply cable grounding wire to the bare copper pigtail in wiring compartment. After making sure the electrical power coming to the heater is turned off at main switch panel follow the desired wiring diagram, as shown in Figure 5, to connect the power supply to the heater using approved wire nuts. (1 Figure. 3 Wiring Compartment Dimensions 2. 3. 4. 5. 6. ! WARNING To prevent a possible fire, make sure all wire connections are tight. Drill hole in wall (or floor) at desired location for power supply entry. Install power supply wiring to heater and thermostat location as determined by thermostat option selected. Allow approximately 10 to 12in(254mm to 305mm) of wire at heater for connections. If any other Marley accessories are to be used with this heater, refer to installation instructions provided with the accessory for proper installation and wiring. Wireway Cover - Commercial Baseboard Only a. The wireway cover is a factory installed feature of Marley commercial baseboard heaters. Two cables or four individual conductors plus two ground wires may be routed through the wireway. Refer to page 2 for maximum current loads. b. To gain access to wireway, lay heater face down and remove two screws as shown in Figure 4. Remove the knockouts in the channel areas of both terminal boxes. c. Insert the plastic bushings from the parts kit (in wiring compartment) in the knockout holes. d. Wire heater according to Figure 5. Reattach the wireway cover using the two screws. Loosen screw in built-in cable clamp or remove desired knockout from heater wiring compartment (Figures 3 and 4). Install power cable into wiring compartment allowing at least 6in(153mm) of cable for connection to heater. To install two power cables using the built-in cable clamp, bend tab covering second hole up and back to rear wall of wiring compartment. If built-in cable clamp is not used, install approved cable connector (not included ) in desired knockout. Position heater to wall (use cross stamped perforations as a guide, see Figure 4) and secure through the top row of predrilled mounting holes using at least two fasteners, one at each end of the heater. If the unit is mounted above the floor to allow carpet installation under the heater, two additional mounting holes are supplied at each end below the element. This will allow you to screw into the sill plate if the unit does not span across two wall studs. Figure 5. NOTE: When accessories are installed, use wiring diagram supplied with the accessory. 9. If front cover was removed, reinstall by hooking the top edge on the support bracket(s). Then push down to latch onto the support bracket(s). 10. Replace wiring compartment cover. 11. Follow instructions accompanying thermostat for installation and wiring thermostat. See Figure 6 for typical thermostat wiring diagrams. Double Line Break Thermostat Power supply L2 Single Line Break Thermostat Power supply L2 L1 L1 (HOT) Breaks on temp. rise and in “OFF” position Breaks in “OFF” position Breaks on temp. rise To heater Double line break thermostats have an “OFF” switch that is open only when the thermostat is put in the “OFF” position TOP MOUNTING PERFORATIONS Figure 6. Typical Thermostats BOTTOM MOUNTING HOLES Figure 4. 3 To heater Single line break thermostats DO NOT have an “OFF” position and will operate at a temperature below its minimum set point 1. 2. 3. OPERATION After the baseboard system has been completely installed, all thermostats should be turned to LOW or NO HEAT. Then turn on breakers. Wait 3 to 5 minutes and check to see that none of the heaters are operating. If operating, disconnect power and check wiring. If none are operating then turn thermostats to highest position and wait 3 to 5 minutes. Check to see that all heater(s) are operating. Should any not be operating, disconnect power and check wiring. Allow entire system to operate steadily for 1/2 hour. This should remove oily residue from manufacturing. (Some smoking may occur). Select the setting for comfort on all thermostats. NAMEPLATE MODEL NO. C2570WC VOLTS AC CLEANING Because of the convection heating principle which depends on air circulation through the finned element, dust will collect between the fins. The heater should be cleaned regularly for maximum efficiency. Before cleaning be sure the heater is off and the element is cool. A vacuum cleaner with a brush attachment may be used for cleaning. The finish of the heater may be cleaned with a slightly damp rag if desired. 60HZ DATE CODE WATTS E L P M EXA 277/240/208 9.1/8.0/7.0 1294 AMPS 2500/1900/1450 54E1 LISTED BASEBOARD HEATER MARLEY ENGINEERED PRODUCTS BENNETTSVILLE, SC 29512 PAINTING Painting of this baseboard is not necessary unless to match room decor. To paint, first rough up the exterior with steel wool. Paint only the exterior of the cabinet. Do not allow paint on the element and high limit capillary tube. Use a high quality enamel paint. PATENT PENDING 4104-2109-265 LIMITED WARRANTY All products manufactured by Marley Engineered Products are warranted against defects in workmanship and materials for one year from date of installation, except heating elements which are warranted against defects in workmanship and materials for ten years from date of installation. This warranty does not apply to damage from accident, misuse, or alteration; nor where the connected voltage is more than 5% above the nameplate voltage; nor to equipment improperly installed or wired or maintained in violation of the product’s installation instructions. All claims for warranty work must be accompanied by proof of the date of installation. The customer shall be responsible for all costs incurred in the removal or reinstallation of products, including labor costs, and shipping costs incurred to return products to Marley Engineered Products Service Center. Within the limitations of this warranty, inoperative units should be returned to the nearest Marley authorized service center or the Marley Engineered Products Service Center, and we will repair or replace, at our option, at no charge to you with return freight paid by Marley. It is agreed that such repair or replacement is the exclusive remedy available from Marley Engineered Products. THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS AGREEMENT. MARLEY ENGINEERED PRODUCTS SHALL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES ARISING WITH RESPECT TO THE PRODUCT, WHETHER BASED UPON NEGLIGENCE, TORT, STRICT LIABILITY, OR CONTRACT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. HOW TO ORDER REPAIR PARTS In order to obtain any needed repair or replacement parts, warranty service or technical information, please contact Marley Engineered Products Service Center tollfree by calling 1-800-642-HEAT. When ordering repair parts, always give the information listed as follows: 1. The Part Number 2. The Model Number 3. The Part Description 4. Date of Manufacture For the address of your nearest authorized service center, contact Marley Engineered Products in Bennettsville, SC, at 1-800-642-4328. Merchandise returned to the factory must be accompanied by a return authorization and service identification tag, both available from Marley Engineered Products. When requesting return authorization, include all catalog numbers shown on the products. ECR 35194 Part No. 5200-2194-007 3-02 4 SPX Corporation 470 Beauty Spot Rd. East Bennettsville, SC 29512 USA
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : Yes Create Date : 2002:05:23 12:05:23 Producer : Acrobat Distiller 4.0 for Macintosh Author : Marley Engineered Products Title : 5200-2194-007 Creator : QuarkXPress(tm) 4.11 Modify Date : 2002:05:23 12:05:34-04:00 Page Count : 4EXIF Metadata provided by EXIF.tools