ITEM NO._______________________________________________________
PROJECT_ ______________________________________________________
LOCATION______________________________________________________
DATE__________________________ QTY.____________________________

TAC/TAF SERIES

Foodservice Solid Door
Reach-ins

REFRIGERATORS	

FREEZERS

❑ TAC-27HDSA	
❑ TAC-48HDSA	
❑ TAC-74HDSA	

❑ TAF-27HDSA	
❑ TAF-48HDSA	
❑ TAF-74HDSA

TAF-48HDSA

FEATURES
STANDARD
ELECTRONIC CONTROL
ON TAF MODELS
• Allows user to easily monitor
defrost functions from the panel
interface on the front of the
merchandiser
• Audible and visual alarm
• Decreases service time and calls
• Eliminates room thermostat,
defrost termination/fan delay
control, defrost timer and digital
thermometer or other temperature
indicator

CONSTRUCTION
• All stainless steel finish interior and
exterior
• Top mounted low profile interior
evaporator housing
• Digital thermometer on TAC models
(built into electronic controller
interface on TAF models)
• Electric condensate evaporator
• Heavy-duty casters
• Three heavy-duty, welded wire, gray
epoxy-coated shelves per section,
adjustable in 1/2" increments
• 21/2" foamed-in-place “zero ODP”
urethane insulated walls

REFRIGERATION
• TAC model refrigerant: R-134a
• TAF model refrigerant: R-404A
• Top mounted, self-contained,
factory tested refrigeration system
• TAF models feature auto defrost with
double failsafe override
• Electric condensate evaporator
• TAC model temperature range:
34° to 41°F (1° to 5°C)
• TAF model temperature range:
0° to -20°F (-18° to -29°C)
• R-factor (insulation efficiency
rating): 21.55 on walls, 17.24 on
doors

DOORS
• 2" stainless steel foamed-in-place doors
• Self-closing with cylinder locks and
90° hold-open feature
• Horizontal door handles
• Self-sealing replaceable magnetic
gaskets
• Lift-off doors
• Anti-condensate door frame heaters
• Light switch concealed in door hinge
• Door width:
TAC/TAF-27HDSA............... 273/4"
TAC/TAF-48HD/74HDSA.... 233/8"

WARRANTY
• Standard limited four year extended
compressor and one year limited
parts and labor

OPTIONS
❑ Add suffix “R” for remote system
❑ Legs	
❑ Pan rack
❑ Additional welded wire gray
epoxy shelving

908 Highway 15 North • New Albany, MS 38652
PHONE: 800-647-1284 or 662-534-9061 • FAX: 800-232-3966 or 662-534-6049 • www.master-bilt.com

TAC/TAF SERIES

FOODSERVICE SOLID DOOR REACH-INS
TECHNICAL SPECIFICATIONS
DIMENSIONS
(in.)
MODEL
L
D
H*
MEDIUM TEMP
TAC-27HDSA 31 353/4 801/2
TAC-48HDSA 52 353/4 801/2
TAC-74HDSA 78 353/4 801/2
LOW TEMP
TAF-27HDSA
31 353/4 801/2
TAF-48HDSA
52 353/4 801/2
TAF-74HDSA
78 353/4 801/2

DIMENSIONS
(mm)
L
D
H*

VOLTS**

787 908 2045
1321 908 2045
1981 908 2045

115
115
115

STANDARD CAP. SHIP SHIP
UNIT NO. OF NO. OF SHELF SIZE CU. CU.
WT.
AMPS H.P. DOORS SHELVES (in inches) FT.
FT. LB/KG
12.1
13.1
15.0

787 908 2045
115
10.5
1321 908 2045 115/208-230 5.0/7.5
1981 908 2045 115/208-230 6.2/11.2

1/2
1/2
3/4

1
2
3

3
6
9

251/4 x 26
221/2 x 26
221/2 x 26

25.4 76.0 355/161
45.9 119.0 465/211
71.4 174.0 650/295

3/4
1
11/2

1
2
3

3
6
9

251/4 x 26
221/2 x 26
221/2 x 26

25.4 76.0 385/175
45.9 119.0 540/245
71.4 174.0 670/305

*Height includes casters. **TAF-48HDSA and TAF-74HDSA operate on a minimum of 208 volts. A voltage boosting transformer (part no. 39-01087)
must be used when the supply voltage is less than 208 volts.

��������������������
��������������������
��������������������

PLAN VIEW

SIDE VIEW

LISTINGS

ELEVATION VIEW

HOOKUP
TAC MODELS: Via plug in, 8 foot long, flexible 3 wire 14/3 cord 		
	
with molded plug. 20 amp service is required for all models.
TAF-27HDSA: Via plug in, 8 foot long, flexible 3 wire 14/3 cord with 	
	
molded plug. 15 amp service is recommended.
TAF-48HDSA: Hardwired
TAF-74HDSA: Hardwired with separate junction boxes for 115V and
	
208-	230V and with a maximum 20 amp fuse.

NEMA 5-20P
(TAC MODELS
& TAF-27HDSA)

BID SPECIFICATIONS
Item no. TAC-_____HDSA and/or Item no.
TAF-_____HDSA.
Provide_______(
) Medium Temp
Foodservice Solid Door Reach-in(s), and/or
_______(
) Low Temp Foodservice Solid
Door Reach-In(s). Master-Bilt model no(s).
TAC-_____HDSA and/or TAF_____HDSA.
Cabinet to be constructed of stainless steel
interior and exterior. TAF models will be
equipped with an electronically controlled

monitoring system as well as an automatic
defrost with double failsafe override.
All models to have digital thermometer
(built into electronic controller interface on
TAF models), electric condensate evaporator,
heavy-duty casters, three welded wire, gray
epoxy-coated shelves per section. Doors will
be self-closing with 90° hold-open feature,
locking horizontal handles and door frame
heater.

The refrigeration system will be top
mounted and self-contained using R-134a
refrigerant in TAC models and R-404A in TAF
models. The temperature range will be 34°
to 41°F (1° to 5°C) for TAC models and 0° to
-20°F (-18° to -29°C) for TAF models.
Cabinet to have standard limited 4 year
extended compressor warranty and 1 year
limited parts and labor warranty. Cabinet to
be UL, C-UL and NSF listed.

NOTE: Cabinet designed for optimum performance in air-conditioned area at 75°F ambient and 55% relative humidity.
	
All specifications subject to change without notice.
908 Highway 15 North • New Albany, MS 38652
PHONE: 800-647-1284 or 662-534-9061 • FAX: 800-232-3966 or 662-534-6049 • www.master-bilt.com
1197-5/07-web
©Master-Bilt Products division of Standex International, Inc. All rights reserved. Printed in U.S.A.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c006 1.236519, Wed Jun 14 2006 08:31:24
Create Date                     : 2008:02:13 16:28:06-06:00
Metadata Date                   : 2008:02:13 16:28:07-06:00
Modify Date                     : 2008:02:13 16:28:07-06:00
Creator Tool                    : Adobe InDesign CS3 (5.0.1)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 13056 bytes, use -b option to extract)
Document ID                     : adobe:docid:indd:77adc52d-6e28-11d9-a2c0-bff88fe63e1a
Instance ID                     : uuid:c7475206-19a8-4c7b-8382-b21d2ba181de
Rendition Class                 : proof:pdf
Derived From Instance ID        : 77adc52c-6e28-11d9-a2c0-bff88fe63e1a
Derived From Document ID        : adobe:docid:indd:14ad993d-6675-11d9-acbb-db9a08049255
Manifest Link Form              : ReferenceStream
Manifest Placed X Resolution    : 300.00
Manifest Placed Y Resolution    : 300.00
Manifest Placed Resolution Unit : Inches
Manifest Reference Instance ID  : uuid:8eaeaa6c-ffc3-11db-afb6-f85dbd387b78
Manifest Reference Document ID  : adobe:docid:photoshop:e36088e1-1b23-11db-8d5d-a23daa0c8d45
Format                          : application/pdf
Producer                        : Adobe PDF Library 8.0
Trapped                         : False
Page Count                      : 2
Creator                         : Adobe InDesign CS3 (5.0.1)
EXIF Metadata provided by EXIF.tools

Navigation menu