Maxtek RFID Q-1000 UHF RFID Reader User Manual RFID Reader User s Guide

Maxtek RFID UHF RFID Reader RFID Reader User s Guide

User Manual

Download: Maxtek RFID Q-1000 UHF RFID Reader User Manual RFID Reader User s Guide
Mirror Download [FCC.gov]Maxtek RFID Q-1000 UHF RFID Reader User Manual RFID Reader User s Guide
Document ID1925453
Application IDDo9If0TmlcwytmPsjZhRHA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize41.35kB (516846 bits)
Date Submitted2013-03-27 00:00:00
Date Available2013-03-27 00:00:00
Creation Date2013-03-22 15:27:37
Producing SoftwareAcrobat Distiller 7.0 (Windows)
Document Lastmod2013-03-22 17:10:36
Document TitleMicrosoft Word - RFID Reader User's Guide
Document CreatorPScript5.dll Version 5.2
Document Author: Administrator

RFID Reader User’s Guide
Version
V11.11
Author
R & D Dept.
This User’s Guide is for salesperson, installing and technical support person of RFID Reader, in order to
make them understand the installing and testing of our readers clearly. Before operating the reader,
please read the guide carefully.
CATALOG
1.
BRIEF INTRODUCTION ............................................................................................................................... 2
1.1
2.
3.
4.
PRODUCT PERFORMANCE .......................................................................................................................... 2
INSTALLATION & CONNECTION .............................................................................................................. 3
2.1
INSTALLATION & POWER SUPPLY .............................................................................................................. 3
2.2
CONNECT TO PC & CONTROLLER .............................................................................................................. 3
WORKING MODE ......................................................................................................................................... 4
3.1
MASTER-SLAVE MODE.............................................................................................................................. 4
3.2
TRIGGER/AUTOMATIC MODE .................................................................................................................... 4
COMMUNICATION PORT ............................................................................................................................ 5
CONNECT TO PC ..................................................................................................................................................... 6
5.
4.1
CONNECT TO CONTROLLER ....................................................................................................................... 6
4.2
CONNECT TO TRIGGER & GPIO................................................................................................................. 6
FAQ .................................................................................................................................................................. 8
1.
Brief Introduction
RFID Reader is one of our developed RFID Readers for UHF Electronic Tags. It supports ISO18000-6B
and EPC Class1 Gen2 protocol so that to read and write the relative tags. With perfect performance and
easy operation, it can be integrated in many applications listed below:
Application
Examples
Description
Vehicle
Parking lot
Charge automation, pass in and out management
Management
Highway Charge
Charge automation for highway, bridge and tunnel
Dock/Container
Container management in road, railway and dock
Vehicle Monitor
Vehicle monitor in traffic management
Logistics
Warehouse
Warehouse, Super market, Mailing, Package management
Management
Manufacture
Monitor the products in production-line
Custom
Goods management for custom clearance
Anti-fake
Anti-fake for products
Access Control
Access control system for staff pass in and out
Work Attendance
Check on work attendance, HR management
Miner
Miner management, insurance
EduToHome
Students management between school and home
Staff Management
1.1
Product Performance
Item
Parameters & Performance
Reader-Tag Protocol
ISO18000-6B, EPC Class1 Gen2
Antenna Port
Integrated antenna, Circular Polarization
Frequency Band
US(902-928MHz)
Frequency Mode
Fixed frequency mode(915MHz)
Communication
RS232/USB/LAN, RS485/Wiegand/GPIO
Identify Tag Range
Read 0 - 15M, depended on environment and tag
--
--
Software Support
Provide Windows API, Demo software with source code
Power Supply
DC 12V supply, less than 2A
Dimension
440x440x80 mm (not including fitting)
Weight
4.0Kg
Pole Diameter
60-70mm
Storage Temp
-30 ~ +85 degree celsius
Operation Temp
-20 ~ +80 degree celsius
Anti-thunder Protection
Shell direct to the ground, communication 1.5KV surge endurance
Work Performance
High speed micro-processor controlled, running steadily
Work Mode
Support Master-Slave mode, Trigger/Automatic mode
Fast Identify
Tags with more than 160Km/h speed can be identified
Upgrade
Firmware can be upgraded easily by RS232/USB/LAN
2.
Installation & Connection
The reader must be installed and connected correctly before operating. First you should connect power
supply and antenna before connecting PC or controller.
2.1
Installation & Power Supply
The reader can be simply installed. Please adjust the fixture to a suitable angle according to your
application.
The maxmium distance between the reader and host varys from data port types. The reliable
communication distance is 10m for RS232, 5m for USB, 15m for Wiegand, 100m for LAN, and 1.0KM for
RS485. Exceeding the above distances is not suggested.
The power input of this reader is 12V DC. An AC to DC adaptor is offered. Plug the adaptor into DC
connector of reader before operating. If the reader makes a sound of a long Beep, the power input is
normal.
2.2
Connect to PC & Controller
The reader can be connected to PC by RS232, USB(need a RS232 To USB Converter). (For detail
please see Part 4. Communication Port.)
The reader can be connected to controller by RS485 or WIEGAND. It can realize input / output operation
and response to outer trigger or GPIO port(not lead out by default). (For detail please see Part 4.
Communication Port.)
3.
Working Mode
The reader can identify working modes automatically and make corresponding response.
3.1
Master-Slave Mode
Under Master-Slave working mode, readers must be controlled by host machine (PC or controller). It
receives the command from host, executing read/write actions on tags, and responsing the data to the
host. Before receiving command from host, reader will stay idle.
We provide SDK software package for reader. This kit package includes Serial Port Communication
Protocol, API functions set and Demo sample program. API functions set and Demo sample program is
for PC to communicate with reader, while Serial Port Communication Protocol is for Controller to
communicate with reader.
3.2
Trigger/Automatic Mode
Under Trgger/Automatic working mode, reader will detect tag automatically in periodical time. After that, it
will response data to the host. In this mode reader does not need to wait command from the host.
4.
Communication Port
The reader has kinds of communication ports. It can communicate with PC or controller that has standard
RS232,RS485 or Wiegand port. The communication ports of the reader include:
Port Name
Port Type
Port Qty.
Application
TRIGGER
IN
1 Pcs
Connect Reader to outer Relay
RS-485
A+,B-
1 Group
Connect Reader to Controller
WIEGAND
D0,D1
1 Group
Connect Reader to Controller
RS-232
DB9 Female Port
1 Pcs
Connect Reader to PC
LAN
RJ45 Port
1 Pcs
Connect Reader to PC/HUB
GPIO
GPI, GPO
Optional, not lead out by default
General Input/Output
Connect to PC
The reader can be connected to PC by RS232 or LAN.
RS232
The reader has a DB9 RS232 port which is usually connected to PC for communication. Directly connect
RS232 of reader to the COM port of PC with DB9 Female cable. The inner connecting relationship is
illustrated below:
4.1
Connect to Controller
The reader can be connected to controller by RS485 or WIEGAND.
RS485
The reader has a RS485 connector, which is usually used for connection between reader and controller.
It can be intergrated to RS485 network or connected to PC through a converter. RS485 should be a twist
masked cable, with 1000m of reliable communication distance. RS485 cable consists of two difference
signal wires: RS485A+(A+) and RS485B-(B-).
Wiegand
The reader has a Wiegand connector, which is usually used for connection between reader and controller.
Wiegand should be a twist masked cable, within 10m of reliable communication distance. Wiegand cable
consists of three signal wires: Data0(D0), Data1(D1) and Ground(GND). Please make sure the good
connection to the ground.
4.2
Connect to Trigger & GPIO
The reader can response outer trigger. It can realize input/output by GPIO, too.
Trigger
In Trigger connection, you should touch IN to GND by outer trigger. For example, you may add a relay to
realize a trigger from ground sensor or key-pressing. The suggested connecting method is illustrated
below:
GPIO
Note: By default we do not give GPIO, user may ask us to customize them if needed.
In GPIO connection, you should connect GPO(Output) and GPI(Input) to the outer equipment. The GPO
could be connected to outer equipment(eg. Relay) to drive the barrier or light.
5.
FAQ
The frequent asked questions and the resolutions are listed below:
Failure
Tag unreadable
Power does not work
Possible Reason
Solution
Tag is too far from antenna
Move the tag close to antenna
Tag direction does not match the antenna
Please face tag to antenna, and keep the correct
polarization
polarization
Tag has been damaged
Change a new tag
Poor contact for power plug
Check the power supply, use the correct power
FCC Warning
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void
your authority to operate this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2013:03:22 17:10:36+08:00
Create Date                     : 2013:03:22 15:27:37+08:00
Metadata Date                   : 2013:03:22 17:10:36+08:00
Format                          : application/pdf
Title                           : Microsoft Word - RFID Reader User's Guide
Creator                         : Administrator
Document ID                     : uuid:4d77cfb8-c9aa-4710-b393-7a20788ce85c
Instance ID                     : uuid:dc7c2366-933e-4b8a-9e19-025d6e8de0ef
Page Count                      : 9
Author                          : Administrator
EXIF Metadata provided by EXIF.tools
FCC ID Filing: SFRQ-1000

Navigation menu