Maxtronic Co DESKFORCE Disk Array User Manual 8190 Ch2

Maxtronic International Co Ltd Disk Array 8190 Ch2

users manual 3

Download: Maxtronic Co DESKFORCE Disk Array User Manual 8190 Ch2
Mirror Download [FCC.gov]Maxtronic Co DESKFORCE Disk Array User Manual 8190 Ch2
Document ID252956
Application IDNUPv5nCfBj0jJI8UfSwK4A==
Document Descriptionusers manual 3
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize110.86kB (1385707 bits)
Date Submitted2002-06-27 00:00:00
Date Available2002-06-26 00:00:00
Creation Date2002-03-04 13:56:18
Producing SoftwareCorel PDF Engine Version 9.397
Document Lastmod2002-03-04 13:56:18
Document Title8190-Ch2.cdr
Document CreatorCorelDRAW Version 9.397
Document Author: Y.M.

Chapter 2 : " Getting Started "
General Overview
This chapter helps you get ready to use the Disk Array. It gives you :
Unpacking & Checklist
Choosing a place for Disk Array
Identifying Parts of Disk Array
Power Source
Installing the Hard Disk Drives
Host Linkage
Power-On and Self-test
LED Display and Function Keys
LCD Status Display
The following illustrations will help you read the further sections.
Special Note :
RAID should never be considered a replacement for doing
regular backup. It's highly recommended to conduct a
backup strategy for critical data.
2-1
Getting Started
Unpacking & Checklist
Before unpacking your Disk Array , prepare a clean and stable
place to put the contents of your Disk Array's shipping container on.
Altogether, you should find the following items in the package :
The Disk Array
One AC power cord
One External SCSI cable
Keys ( For HDD Trays )
User Manual
RS-232 Cable
Remove all the items from the carton. If anything is missing or
broken , please inform your dealer immediately.
Save the cartons and packing materials that came with the Disk
Array. Use these materials for shipping or transporting the Disk Array.
Figure : Checklist
2-2
Getting Started
Choosing a place for Disk Array
When selecting a place to set up your Disk Array, be sure to follow
the guidelines as below:
Place on a flat and stable surface.
Use a stand that supports at least 50kgs for this Disk Array.
(HDD included )
Place the Disk Array close enough to the computer for the Disk
Array's External SCSI cable to reach it.
Use a grounded wall outlet.
Avoid an electrical outlet controlled by wall switches or
automatic timers. Accidental disruption of the power source
may wipe out data in the memory of your computer or Disk
Array.
Keep the entire system away from potential sources of
electromagnetic interference, such as loudspeakers, cordless
telephones, etc.
Caution !
Avoid direct sunlight, excessive heat, moisture, or dust.
2-3
Getting Started
Identifying Parts of the Disk Array
Front View
Figure : Front View
1. LCD Status Display Panel
2. HDD Trays 1 ~ 8
3. Power Supply Status Indicator ( light up Green / Red )
4. Function Keys ( , , Enter , ESC )
5. Power-On Indicator ( PWR Unit 1 , PWR Unit 2 )
6. Host Computer Access Indicator
7. HDD Tray Lock ( Lock / Unlock )
8. HDD Status Indicator
(From left to right: Error (Red), Access (Yellow), Power-On (Green))
9. Front Cover
2-4
Getting Started
Rear View
10
11
12
13
14
Figure : Rear View
1. Host channel adapter Port
2. RS232 Adapter ( Terminal Port )
3. Cooling Fans
4. Power Supply Unit Switch ( On / Off )
5. Power Supply Unit 1 LED Indicator ( Green )
6. Power Supply Unit 1 ( Upper )
7. Power Supply Unit 2 ( Lower )
8. Reserved #2 Host Channel Port
9. Fan Door Screws
10. Power Supply fail Indicator ( RED )
11. Power Supply Alarm Reset Switch
12. AC Power Source Input Socket
13. AC Voltage Select Switch ( 115V / 230V )
14. Power Supply Unit Switch ( On / Off )
2-5
Getting Started
Power Source
Choosing a Working Voltage
The system can run either on AC 115V (+/10%) or AC 230V
(+/10%), Slide the AC voltage select switch on both of the two
power supply units to the correct position which corresponds
with the wall outlet supply voltage.
Warning !
Wrong AC Voltage input will harm the power supply and
cause serious damage to the Disk Array.
Figure : Power Source
! This Disk Array must be grounded
This Disk Array is supplied with an AC power cord equipped with
a 3-wire grounding type plug. This is a safety feature and it is
important to only use a 3-wire grounded mains power cord.
2-6
Getting Started
Installing the Hard Disk Drives
Step 1 : Open the front cover.
Figure : Installing HDD step 1
2-7
Getting Started
Step 2 : Unlock the HDD tray by turning the Key-lock to the
correct position.
Step 3 : Gently Pull out the HDD tray.
Figure : Installing HDD step 2, 3
2-8
Getting Started
Step 4 : Insert HDD into the tray
Step 5 : Screw in the hard drive.
( Use the correct size, type and thread )
Step 6 : Cabling, Connect the Data cable , SCSI ID cable
& Power cable.
Cabling
SCREWS
SCREWS
Figure : Installing HDD step 4, 5, 6
2-9
Getting Started
Step 7 : Gently slide in the HDD tray.
Step 8 : Lock the HDD tray. When powered on the Green LED
will light up.
Figure : Installing HDD step 7, 8
2-10
Getting Started
Host Linkage
With the HDD(s) installed correctly, you are ready to connect the
Disk Array to your Host computer.
Use a shielded twisted-pair SCSI cable to connect your Host
computer to the Disk Array's built-in 68 pin SCSI adapter port.
Connect the Host computer as shown below :
SCSI
Plug
Disk Array
Host Computer
Figure : Host linkage
Caution !
For safety reasons, make sure the Disk Array and Host Computer
are turned off when you plug-in the SCSI cable.
2-11
Getting Started
Power-On and Self-Test
When you connect the Disk Array to the Host computer, You
should press the ON/OFF Power Supply Switch on both of the
power supply Hot-Swap units and the Main Switch.
It will turn the Disk Array on and the Self-Test will be started
automatically.
Power Supply Main Switch
Figure : Power-On & Self-Test
2-12
Getting Started
LED Display & Function Keys
LED Display
Shown below is the LED Display. Please refer to the illustration,
the LEDs inform you of the Disk Array's current operating status.
Upon activating a certain function, the corresponding LED
indicator should turn on indicating that the feature is engaged.
Figure : LED Display
LED
Descriptions
1. Power Unit 1 Indicator
light up : "Green" , it lights when the Power Unit 1
is plugged and operating functionally.
2. Power Unit 2 Indicator
light up : "Green" , it lights when the Power Unit 2
is plugged and operating functionally.
3. Host Computer Access
Indicator
light up : "Yellow" , Indicates Host
computer is currently accessing the Disk Array
4. HDD Power-On Indicator
light up : "Green" , It lights when the HDD frame
is locked and Power-On
5. HDD Access Indicator
light up : "Yellow" , when HDD is accessed
6. HDD Error Indicator
light up : "Red" , when HDD is not installed or HDD error
2-13
Getting Started
Function Keys
The four function keys at the top of the front panel perform the
following functions :
) Up Arrow / Right Arrow
Use to scroll the cursor Upward / Rightward
) Down Arrow / Left Arrow
Use to scroll the cursor Downward / Leftward
( Enter )
Use to confirm a selected item
( ESC )
Use to exit a selection
2-14
Getting Started
LCD Status Panel
Located the LCD panel, the LCD status panel informs you of the
Disk Array's current operating status at a glance. Upon activating
a certain function, a symbol or icon corresponding to that
function will appear in the display window. The symbol will remain
in the display window indicating the status of the Disk Array.
Identifying the status on the LCD
The following illustration shows the symbols (characters) been
used and their representation.
A description of each of the symbols in LCD display window :
On-line and functional
Error occur
Identifying Disk Drive
Spare Disk Drive
Disk Drive not installed
Warning : Disk Drive with too many Bad Sectors
Example of the LCD status display window :
OOOOOSXX R5 ID:0
This informs you :
a. HDD 1 ~ HDD 5
b. HDD 6
c. HDD 7 ~ HDD 8
d. RAID Level
e. SCSI ID
Online
It is a Spare disk drive
Not installed
In " RAID Level 5 "
In " ID# 0 "
2-15

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 15
Create Date                     : 2002:03:04 13:56:18
Modify Date                     : 2002:03:04 13:56:18
Producer                        : Corel PDF Engine Version 9.397
Author                          : Y.M.
Creator                         : CorelDRAW Version 9.397
Title                           : 8190-Ch2.cdr
EXIF Metadata provided by EXIF.tools
FCC ID Filing: NKF-DESKFORCE

Navigation menu