Maytag Range Mgr5750Bdb Users Manual
MGR5750BDW to the manual 66216b5c-7976-4b57-a1c7-0893e1ad5a71
2015-01-23
: Maytag Maytag-Maytag-Range-Mgr5750Bdb-Users-Manual-270306 maytag-maytag-range-mgr5750bdb-users-manual-270306 maytag pdf
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
www.dexpress.com DIMENSION EXPRESS This Data Sheet Includes Information On Maytag • Product Model Number (s): • Free Standing Gas Ranges: MGR5750BDW, MGR5750BDQ and MGR5750BDB • Dimensions (Actual Size) Height of cooking surface: 35 7/8" Fax on Demand (775) 833-3600 29 7/8" (not to scale) • Height overall: 46 3/4" 46 3/4" Case width: 29 7/8" Depth NOT including handle: 25 1/2" 35 7/8" Door swing: 20" 20" Height at full leg adjustment: 36" Height at 0" leg adjustment: 35 1/2" • Additional Information • • Units depth including door handle is 28 1/8". • Can be installed with the back against (0") a vertical combustible wall, and the sides below the cooktop surface against (0") combustible base cabinets. • Electrical requirements: 120 VAC,60Hz. 15 amp grounded circuit protection is required. • Gas requirements: Gas supply line should be 3/4". Install a manual shutoff valve in an accessible location in the gas line external to this appliance for the purpose of turning on or shutting off gas to the appliance. The appliance is shipped from the factory equipped for use with natural gas and can be converted to LP gas in the field . The maximum gas supply pressure for both LP and natural gas is 14" WC. Minimum Pressure for Natural gas is 4" WC. Minimum Pressure for LP gas is 10" WC. • Proper operation requires use of range hood. • Cabinetry over cooktop : 30' minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet. 24" minimum when bottom of wood or metal cabinet is protected by not less than 1/4" flame retardant millboard covered with not less than no. 28 MSG sheet steel, 0.015" stainless steel, 0.024" aluminum or copper. Door open 25 1/2" 1" Locate gas line within shadded area Wall View (not to scale) Locate electrical supply outlet (flush with wall) within hashed area. Area is 13" W X 9" H. located 9 3/8" above floor and 1 1/2" from right wall. 28" Electric Location 18" Gas Location 2 1/4" Wall View (not to scale) 30" See page 2 for additional information Upper cabinets can only be 13" deep maximum. Over range cabinet is NOT recommended. 30" Min. 18" Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or outdated data sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall not exceed $50.00. Copyright © Dimension Express, 2002. 255 • NEVER reuse Data Sheets. Data Sheets are subject to change without notice. Dimension Express is a FREE service bureau and is updated daily, it makes far more sense to spend the time necessary to request new Data Sheets for each project, as opposed to the problems, time, costs, and risks associated with reusing old Data Sheets. 36" Countertop height Range Side clearance from cooktop to 18" above the cooktop is 3" on each side (see solid arera) 30" Minimum cutout width • Call Dimension Express if you have any questions at (775) 833-3633 • • Always refer to a current Code at a Glance or manufacturer directory • • Data Sheet codes change on the first of odd numbered months at 12:01am • BN • A255B149 • • 032603 • 95657 • 45163 www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600 This Data Sheet Includes Information On Maytag Page 2 • Product Model Number (s): • Free Standing Gas Ranges: MGR5750BDW, MGR5750BDQ and MGR5750BDB Additional Information: • To eliminate the hazard of reaching over heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the hazard can be reduced by installing a range hood that projects horizontally a minimum of 5" beyond the bottom of the cabinets. • For Free-standing installations the cutout opening width is 30" ± 1/16" minimum. The height of the countertop is 36" and countertop depth is 25". • MGR5750ADA : Monochromatic Almond. • MGR5750ADW : Monochromatic White. Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or outdated data sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall not exceed $50.00. Copyright © Dimension Express, 2002. 149 • NEVER reuse Data Sheets. Data Sheets are subject to change without notice. Dimension Express is a FREE service bureau and is updated daily, it makes far more sense to spend the time necessary to request new Data Sheets for each project, as opposed to the problems, time, costs, and risks associated with reusing old Data Sheets. • Call Dimension Express if you have any questions at (775) 833-3633 • • Always refer to a current Code at a Glance or manufacturer directory • • Data Sheet codes change on the first of odd numbered months at 12:01am • BN • A255B149 • • 032603 • 95657 • 45163
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Encryption : Standard V1.2 (40-bit) User Access : Print, Annotate, Fill forms, Extract, Assemble, Print high-res XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Create Date : 2003:03:27 12:19:34Z Creator Tool : FileMaker Pro Modify Date : 2012:09:02 18:15:06-04:00 Metadata Date : 2012:09:02 18:15:06-04:00 Format : application/pdf Description : Creator : Kirk Goddard Title : Keywords : Producer : Acrobat PDFWriter 4.0 for Power Macintosh Document ID : uuid:b8e0c00c-4968-47eb-b2db-1faae6752038 Instance ID : uuid:b66b5da1-b9cc-44c0-8dd3-5e6e68c77b46 Page Count : 2 Subject : Author : Kirk GoddardEXIF Metadata provided by EXIF.tools