Maytag Pgc2Mq Iq Drive M1200 97 Afue Modulating Gas Furnace Technical Literature

2015-03-30

: Maytag Maytag-Pgc2Mq-Iq-Drive-Maytag-M1200-97-Afue-Modulating-Gas-Furnace-Technical-Literature-677877 maytag-pgc2mq-iq-drive-maytag-m1200-97-afue-modulating-gas-furnace-technical-literature-677877 maytag pdf

Open the PDF directly: View PDF PDF.
Page Count: 8

DownloadMaytag Maytag-Pgc2Mq-Iq-Drive-Maytag-M1200-97-Afue-Modulating-Gas-Furnace-Technical-Literature-  Maytag-pgc2mq-iq-drive-maytag-m1200-97-afue-modulating-gas-furnace-technical-literature
Open PDF In BrowserView PDF
TECHNICAL SPECIFICATIONS
Model PGC2MQ Series
SmartStart

®

M1200 Product Line
Fully Modulating, Variable Speed,
High Efficiency Upflow/Horizontal
Gas Furnaces 97.0 AFUE Input 60,000-120,000 Btuh

2

The high efficiency gas furnace
may be installed free standing
in a utility room, basement, or
enclosed in an alcove or closet.
The rounded corner jacket
provides a pleasing “appliance
appearance.” Design certified by
CSA for application in Canada
and the United States.

Features and Benefits
- i SEER : Energy efficient brushless DC (ECM) motor gives up
to 1 SEER point efficiency gain in cooling.
- Modulating heating operation Includes:
- Modulating gas valve from 100% to 50% input
in 5% increments
- Time proportioning modulation down to 15%
- Variable speed inducer and blower.
- 100% fired and tested: All units and each component are
tested on the manufacturing line.
- Best packaging in the industry: Unique corner post design
assures product will arrive to the homeowner dent free.
- 30 second blower delay: At start-up assures a warm duct
temperature at furnace start-up. Adjustable blower off settings
(60, 90, 120 and 180 seconds).
- 30 second post purge: Increases life of heat exchanger.
- Hot surface igniter: Innovative application of an appliance
type igniter with a 20 year history of reliability. Utilizes proven
SmartStart® technology.
- Color coded wire harness: Designed to fit the components, all
with quick-connect fittings for ease of service and replacement.
- Flexible category IV venting system: May be vertically or
horizontally vented using either a one-pipe or two-pipe system
for maximum flexibility in installation.
- High Static Blowers: All models equipped with high static
blowers.
- Low Boy Height: Easy to apply in low ceiling applications,
works well with taller high SEER coils, easier to handle and
install.
- Tubular primary heat exchanger: Heavy gauge aluminized
steel heat exchanger and stainless steel secondary heat
exchanger assures a long life.
- 90 second fixed cooling cycle blower-off delay (TDR): Increases
cooling performance when matched with a NORDYNE coil.
- LP convertible: Simple burner orifice and regulator spring
change for ease of convertibility.
- Diagnostic lights for easy troubleshooting without counting
flashes: Dedicated light for flame signal strength and 2 lights
in combination to indicate all other fault codes with easy to
recognize states without counting flashes.
- Incorporates integrated control board: With connections for
electronic air cleaner, and humidifier.
- Two piece door design: Enhances furnace appearance and
uses captured screws to prevent losing door screws.
- Blower Compartment: Sealed door to reduce air leakage and
insulated for ultra quiet operation.
- Sealed Vestibule: Reduces burner and inducer sound levels.
- iQ Drive Thermostat: Provides modulation down to 15% and
is required for furnace operation.
TM

3

GAS FURNACE COMPONENTS
UPFLOW / HORIZONTAL FURNACE (*MQ SERIES)
Finish
Flange
Roll-Out
Switch

Gas Manifold

Burner
Assembly

Flame Sensor
Igniter
Pressure Switches
Main Air Limit Switch

Gas Valve

Inducer Limit Switch
Inducer Assembly

Furnace Control Board

Blower Door Switch

Transformer

Motor Control Box
Motor Choke
(C & D cabinets only)

Motor Control Board
Blower Assembly

IDENTIFICATION CODE
Maytag Gas
Compact

PGC

2

M

Q

060 D

V

B

Cabinet Width
B = 17.50
C = 21.00
D = 24.50

Design Series
S = Single Stage
T = Two Stage
M = Modulating
A = 80% Upflow/Horizontal
C = 92.1% / 95.1% Upflow/Horizontal
K = 80% Downflow
L = 92.1% / 95.1% Downflow
Q = 97.0% AFUE Upflow/Horizontal

Cooling Airflow
V = VSB

D = 90+% AFUE Low NOx

Input Heating Capacity
060 = 60,000
080 = 80,000

4

100 = 100,000
120 = 120,000

DIMENSIONS
TOP VIEW

BOTTOM VIEW

B

C
Front Brace

FL

AN

19

GE

3 1/4

Electric (Ø 7/8)

Vent pipe
(Ø 3”)

Gas
(Ø 1 5/8)

22 1/2

22 1/2
Gas (Ø 1 5/8)

17 7/8

24 7/8

Vent pipe
(Ø 3”)
17 1/4

34 1/2

T-stat
(Ø 7/8)

A

Electric
(Ø 7/8)

25 3/8

Bottom
Panel

Combustion Air

T-stat
(Ø 7/8)

2 3/4
22 1/2

23 1/2

S

1

4 Knockouts
(both sides)

15

Cond. (Ø 1 1/16)
28

LEFT SIDE

Condensate
(Ø 1 1/16)

*MQ
Model #’s
060DVB
080DVC
100DVC
120DVD

23

FRONT VIEW

1 1/4

RIGHT SIDE

Dimension Dimension Dimension
“A”
“B”
“C”
15 7/8
16 1/8
17 1/2
21

19 3/8

19 5/8

24 1/2

22 7/8

23 1/8

PGC2MQ 97+ Modulating Upflow/Horizontal Series

5

SPECIFICATIONS
PGC2MQ MODEL
NUMBERS:

060DVB

080DVC

100DVC

120DVD

Input - Btuh (a)

60,000 / 30,000

80,000 / 40,000

100,000 / 50,000

120,000 / 60,000

Heating Capacity - Btuh

58,200 / 29,100

77,600 / 38,800

97,000 / 48,500

116,400 / 58,200

97.0

97.2

97.4

97.0

AFUE
Blower D x W

11 x 8

11 x 10

11 x 10

11 x 10

1/2 - Variable

3/4 - Variable

3/4 - Variable

1 - Variable

Motor FLA

6.2

8.7

8.7

11.70

Rated Ext. SP - In. W.C.

0.5

0.5

0.5

0.5

Temperature Rise Range - ºF

30-60

35-65

35-65

40-70

Shipping Weights

130lbs

140lbs

150lbs

165lbs

Motor H.P. - Speed - Type

NOTE: All models are 115V, 60 Hz. Gas Connections are 1/2" N.P.T. AFUE = Annual Fuel Utilization Efficiency
(a) Ratings to 2,000 ft. Over 2,000 ft. reduce 4% for each 1,000 ft. above sea level.

iQ CONTROLLER KIT
Description

Sku

iQ Controller kit

920620*

* Revision Letter

AIRFLOW DATA
Gas Input
Rate
(Btuh)

Target CFM for Selected Circulating Air
Temperature Rises, F
45

50

55

60

Full
Input

Minimum
Input

Full
Input

Minimum
Input

Full
Input

Minimum
Input

Full
Input

Minimum
Input

Constant

60,000

1,110

635

1,000

560

940

515

850

470

950

80,000

1,480

850

1,345

740

1,255

685

1,140

625

1,300

100,000

1,850

1,050

1,680

925

1,565

855

1,460

780

1,760

120,000

2,225

1,270

2,020

1,115

1,890

1,025

1,730

940

2,100

NOTE: This table lists the High and Low target CFMs for each maximum input rate and temperature rise. If the
target CFM is more that 1,600 CFM, it is recommended that two return air openings into the furnace be used.
NOTE: The blower operating range is .1” to .8” ESP in wc.

6

ACCESSORIES
PGC2MQ KITS
Description

SKU

2" Concentric vent kit

904177

3" Concentric vent kit

904176

2" Side wall vent kit

904617

3" Side wall vent kit

904347

U.S. LP Conversion kit (0 to 10,000 ft.) for US and Canada

904950

Bottom return filter 20 per box, "B" cabinet

904916

Bottom return filter 20 per box, "C" cabinet

904917

Bottom return filter 20 per box, "D" cabinet

904918

Side return filter kit

541036

Neutralizer kit

902377

Outdoor Sensor for conventional heatpump

920938

All models are 115 V, 60 HZ. Gas connections are 1/2" N.P.T.
AFUE= Annual Fuel Utilization Efficiency

MAXIMUM PIPE LENGTH
FURNACE
MODELS
(BTU)

60,000
80,000
100,000
120,000

FURNACE
INSTALLATION

SINGLE VENT PIPE LENGTH (FT.)
with 1 long radius elbow*

DUAL VENT PIPE LENGTH (ft.)
with 1 long radius elbow on each pipe*

OUTLET
2” Diameter

OUTLET
3” Diameter

INLET/OUTLET
2” Diameter

INLET/OUTLET
3” Diameter

Upflow

50

80

50

80

Horizontal

40

80

40

80

Upflow

60

90

60

90

Horizontal

50

90

50

90
90

Upflow

50

90

50

Horizontal

40

90

40

90

Upflow

N/A

90

N/A

90

Horizontal

N/A

70

N/A

70

*NOTES:
1 Subtract 2.5 ft. for each additional 2 inch long radius elbow, 5 ft. for each additional 2 inch short radius elbow, 3.5 ft. for each additional 3 inch
long radius elbow, and 7 ft. for each additional 3 inch short radius elbow. Two 45° elbows are equivalent to one 90° elbow.
2. Subtract 5ft for each 2” tee and 8ft for each 3” tee.
3. This table applies for elevations from sea level to 2,000 ft. For higher elevations, decrease pipe lengths by 8% per 1,000 ft of altitude.
4. The minimum length for 2” or 3” diameter vent pipe is 5 ft.

7

Before purchasing this appliance, read important energy cost and efficiency
information available from your retailer. Specifications and illustrations subject
to change without notice and without incurring obligations.
Manufactured under license by NORDYNE, O’Fallon, MO. ®Registered Trademark/ TM Trademark
of Maytag Corporation or its related companies. ©2014. All rights reserved.
046D-0914 (Replaces 046D-0212)
Printed in U.S.A. (09/14)



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Instance ID                     : uuid:fcdb2ce0-0c1b-439e-b588-58f6c93e2ddf
Document ID                     : adobe:docid:indd:a0782be4-c2ed-11dd-abb4-abd8137a1b16
Original Document ID            : adobe:docid:indd:a0782be4-c2ed-11dd-abb4-abd8137a1b16
Rendition Class                 : proof:pdf
Derived From Instance ID        : c5e4e7c2-c2e9-11dd-abb4-abd8137a1b16
Derived From Document ID        : adobe:docid:indd:c5e4e7c1-c2e9-11dd-abb4-abd8137a1b16
History Action                  : saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved
History Instance ID             : xmp.iid:9551E7979554E0118C3ACD2D37FF6F76, xmp.iid:9651E7979554E0118C3ACD2D37FF6F76, xmp.iid:9A4B22B29654E0118C3ACD2D37FF6F76, xmp.iid:A520F15BCA54E0118C3ACD2D37FF6F76, xmp.iid:4F322501CB54E0118C3ACD2D37FF6F76, xmp.iid:50322501CB54E0118C3ACD2D37FF6F76, xmp.iid:6A03C939CB54E0118C3ACD2D37FF6F76, xmp.iid:EF126C6ACC54E0118C3ACD2D37FF6F76, xmp.iid:F9CE797CCC54E0118C3ACD2D37FF6F76, xmp.iid:5E2B60A7CC54E0118C3ACD2D37FF6F76, xmp.iid:5F2B60A7CC54E0118C3ACD2D37FF6F76, xmp.iid:1A4E2F201857E011AE39D35D48B83C3F, xmp.iid:85C05963C442E111B937C9D2E283E9D3, xmp.iid:86C05963C442E111B937C9D2E283E9D3, xmp.iid:F08AAC95C742E111B937C9D2E283E9D3, xmp.iid:6037448CD242E111B937C9D2E283E9D3, xmp.iid:A443B2D5DF45E111938AD4CE3B5DAE44, xmp.iid:18C6C5F8DF45E111938AD4CE3B5DAE44, xmp.iid:01E304699537E411845DA59574533DD8, xmp.iid:445F25279637E411845DA59574533DD8
History When                    : 2011:03:22 10:03:49-05:00, 2011:03:22 10:03:49-05:00, 2011:03:22 10:11:43-05:00, 2011:03:22 16:21:32-05:00, 2011:03:22 16:26:09-05:00, 2011:03:22 16:26:31-05:00, 2011:03:22 16:27:44-05:00, 2011:03:22 16:36:15-05:00, 2011:03:22 16:36:45-05:00, 2011:03:22 16:37:57-05:00, 2011:03:22 16:43:59-05:00, 2011:03:25 14:43:15-05:00, 2012:01:19 11:38:24-06:00, 2012:01:19 11:38:24-06:00, 2012:01:19 12:01:17-06:00, 2012:01:19 13:19:46-06:00, 2012:01:23 10:32:26-06:00, 2012:01:23 10:33:25-06:00, 2014:09:08 15:19:17-05:00, 2014:09:08 15:24:36-05:00
History Software Agent          : Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5
History Changed                 : /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata
Create Date                     : 2014:09:24 15:58:26-05:00
Modify Date                     : 2014:09:24 15:58:26-05:00
Metadata Date                   : 2014:09:08 15:25:41-05:00
Creator Tool                    : Adobe InDesign CS5.5 (7.5)
Page Image Page Number          : 1, 2
Page Image Format               : JPEG, JPEG
Page Image Width                : 256, 256
Page Image Height               : 256, 256
Page Image                      : (Binary data 8399 bytes, use -b option to extract), (Binary data 3194 bytes, use -b option to extract)
Doc Change Count                : 274
Format                          : application/pdf
Title                           : untitled
Producer                        : Acrobat Distiller 10.1.7 (Windows)
Trapped                         : False
Page Count                      : 8
Creator                         : Adobe InDesign CS5.5 (7.5)
EXIF Metadata provided by EXIF.tools

Navigation menu