Maytag Pgc2Mq Iq Drive M1200 97 Afue Modulating Gas Furnace Technical Literature
2015-03-30
: Maytag Maytag-Pgc2Mq-Iq-Drive-Maytag-M1200-97-Afue-Modulating-Gas-Furnace-Technical-Literature-677877 maytag-pgc2mq-iq-drive-maytag-m1200-97-afue-modulating-gas-furnace-technical-literature-677877 maytag pdf
Open the PDF directly: View PDF
.
Page Count: 8
| Download | |
| Open PDF In Browser | View PDF |
TECHNICAL SPECIFICATIONS Model PGC2MQ Series SmartStart ® M1200 Product Line Fully Modulating, Variable Speed, High Efficiency Upflow/Horizontal Gas Furnaces 97.0 AFUE Input 60,000-120,000 Btuh 2 The high efficiency gas furnace may be installed free standing in a utility room, basement, or enclosed in an alcove or closet. The rounded corner jacket provides a pleasing “appliance appearance.” Design certified by CSA for application in Canada and the United States. Features and Benefits - i SEER : Energy efficient brushless DC (ECM) motor gives up to 1 SEER point efficiency gain in cooling. - Modulating heating operation Includes: - Modulating gas valve from 100% to 50% input in 5% increments - Time proportioning modulation down to 15% - Variable speed inducer and blower. - 100% fired and tested: All units and each component are tested on the manufacturing line. - Best packaging in the industry: Unique corner post design assures product will arrive to the homeowner dent free. - 30 second blower delay: At start-up assures a warm duct temperature at furnace start-up. Adjustable blower off settings (60, 90, 120 and 180 seconds). - 30 second post purge: Increases life of heat exchanger. - Hot surface igniter: Innovative application of an appliance type igniter with a 20 year history of reliability. Utilizes proven SmartStart® technology. - Color coded wire harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement. - Flexible category IV venting system: May be vertically or horizontally vented using either a one-pipe or two-pipe system for maximum flexibility in installation. - High Static Blowers: All models equipped with high static blowers. - Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install. - Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger and stainless steel secondary heat exchanger assures a long life. - 90 second fixed cooling cycle blower-off delay (TDR): Increases cooling performance when matched with a NORDYNE coil. - LP convertible: Simple burner orifice and regulator spring change for ease of convertibility. - Diagnostic lights for easy troubleshooting without counting flashes: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes with easy to recognize states without counting flashes. - Incorporates integrated control board: With connections for electronic air cleaner, and humidifier. - Two piece door design: Enhances furnace appearance and uses captured screws to prevent losing door screws. - Blower Compartment: Sealed door to reduce air leakage and insulated for ultra quiet operation. - Sealed Vestibule: Reduces burner and inducer sound levels. - iQ Drive Thermostat: Provides modulation down to 15% and is required for furnace operation. TM 3 GAS FURNACE COMPONENTS UPFLOW / HORIZONTAL FURNACE (*MQ SERIES) Finish Flange Roll-Out Switch Gas Manifold Burner Assembly Flame Sensor Igniter Pressure Switches Main Air Limit Switch Gas Valve Inducer Limit Switch Inducer Assembly Furnace Control Board Blower Door Switch Transformer Motor Control Box Motor Choke (C & D cabinets only) Motor Control Board Blower Assembly IDENTIFICATION CODE Maytag Gas Compact PGC 2 M Q 060 D V B Cabinet Width B = 17.50 C = 21.00 D = 24.50 Design Series S = Single Stage T = Two Stage M = Modulating A = 80% Upflow/Horizontal C = 92.1% / 95.1% Upflow/Horizontal K = 80% Downflow L = 92.1% / 95.1% Downflow Q = 97.0% AFUE Upflow/Horizontal Cooling Airflow V = VSB D = 90+% AFUE Low NOx Input Heating Capacity 060 = 60,000 080 = 80,000 4 100 = 100,000 120 = 120,000 DIMENSIONS TOP VIEW BOTTOM VIEW B C Front Brace FL AN 19 GE 3 1/4 Electric (Ø 7/8) Vent pipe (Ø 3”) Gas (Ø 1 5/8) 22 1/2 22 1/2 Gas (Ø 1 5/8) 17 7/8 24 7/8 Vent pipe (Ø 3”) 17 1/4 34 1/2 T-stat (Ø 7/8) A Electric (Ø 7/8) 25 3/8 Bottom Panel Combustion Air T-stat (Ø 7/8) 2 3/4 22 1/2 23 1/2 S 1 4 Knockouts (both sides) 15 Cond. (Ø 1 1/16) 28 LEFT SIDE Condensate (Ø 1 1/16) *MQ Model #’s 060DVB 080DVC 100DVC 120DVD 23 FRONT VIEW 1 1/4 RIGHT SIDE Dimension Dimension Dimension “A” “B” “C” 15 7/8 16 1/8 17 1/2 21 19 3/8 19 5/8 24 1/2 22 7/8 23 1/8 PGC2MQ 97+ Modulating Upflow/Horizontal Series 5 SPECIFICATIONS PGC2MQ MODEL NUMBERS: 060DVB 080DVC 100DVC 120DVD Input - Btuh (a) 60,000 / 30,000 80,000 / 40,000 100,000 / 50,000 120,000 / 60,000 Heating Capacity - Btuh 58,200 / 29,100 77,600 / 38,800 97,000 / 48,500 116,400 / 58,200 97.0 97.2 97.4 97.0 AFUE Blower D x W 11 x 8 11 x 10 11 x 10 11 x 10 1/2 - Variable 3/4 - Variable 3/4 - Variable 1 - Variable Motor FLA 6.2 8.7 8.7 11.70 Rated Ext. SP - In. W.C. 0.5 0.5 0.5 0.5 Temperature Rise Range - ºF 30-60 35-65 35-65 40-70 Shipping Weights 130lbs 140lbs 150lbs 165lbs Motor H.P. - Speed - Type NOTE: All models are 115V, 60 Hz. Gas Connections are 1/2" N.P.T. AFUE = Annual Fuel Utilization Efficiency (a) Ratings to 2,000 ft. Over 2,000 ft. reduce 4% for each 1,000 ft. above sea level. iQ CONTROLLER KIT Description Sku iQ Controller kit 920620* * Revision Letter AIRFLOW DATA Gas Input Rate (Btuh) Target CFM for Selected Circulating Air Temperature Rises, F 45 50 55 60 Full Input Minimum Input Full Input Minimum Input Full Input Minimum Input Full Input Minimum Input Constant 60,000 1,110 635 1,000 560 940 515 850 470 950 80,000 1,480 850 1,345 740 1,255 685 1,140 625 1,300 100,000 1,850 1,050 1,680 925 1,565 855 1,460 780 1,760 120,000 2,225 1,270 2,020 1,115 1,890 1,025 1,730 940 2,100 NOTE: This table lists the High and Low target CFMs for each maximum input rate and temperature rise. If the target CFM is more that 1,600 CFM, it is recommended that two return air openings into the furnace be used. NOTE: The blower operating range is .1” to .8” ESP in wc. 6 ACCESSORIES PGC2MQ KITS Description SKU 2" Concentric vent kit 904177 3" Concentric vent kit 904176 2" Side wall vent kit 904617 3" Side wall vent kit 904347 U.S. LP Conversion kit (0 to 10,000 ft.) for US and Canada 904950 Bottom return filter 20 per box, "B" cabinet 904916 Bottom return filter 20 per box, "C" cabinet 904917 Bottom return filter 20 per box, "D" cabinet 904918 Side return filter kit 541036 Neutralizer kit 902377 Outdoor Sensor for conventional heatpump 920938 All models are 115 V, 60 HZ. Gas connections are 1/2" N.P.T. AFUE= Annual Fuel Utilization Efficiency MAXIMUM PIPE LENGTH FURNACE MODELS (BTU) 60,000 80,000 100,000 120,000 FURNACE INSTALLATION SINGLE VENT PIPE LENGTH (FT.) with 1 long radius elbow* DUAL VENT PIPE LENGTH (ft.) with 1 long radius elbow on each pipe* OUTLET 2” Diameter OUTLET 3” Diameter INLET/OUTLET 2” Diameter INLET/OUTLET 3” Diameter Upflow 50 80 50 80 Horizontal 40 80 40 80 Upflow 60 90 60 90 Horizontal 50 90 50 90 90 Upflow 50 90 50 Horizontal 40 90 40 90 Upflow N/A 90 N/A 90 Horizontal N/A 70 N/A 70 *NOTES: 1 Subtract 2.5 ft. for each additional 2 inch long radius elbow, 5 ft. for each additional 2 inch short radius elbow, 3.5 ft. for each additional 3 inch long radius elbow, and 7 ft. for each additional 3 inch short radius elbow. Two 45° elbows are equivalent to one 90° elbow. 2. Subtract 5ft for each 2” tee and 8ft for each 3” tee. 3. This table applies for elevations from sea level to 2,000 ft. For higher elevations, decrease pipe lengths by 8% per 1,000 ft of altitude. 4. The minimum length for 2” or 3” diameter vent pipe is 5 ft. 7 Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Manufactured under license by NORDYNE, O’Fallon, MO. ®Registered Trademark/ TM Trademark of Maytag Corporation or its related companies. ©2014. All rights reserved. 046D-0914 (Replaces 046D-0212) Printed in U.S.A. (09/14)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Instance ID : uuid:fcdb2ce0-0c1b-439e-b588-58f6c93e2ddf Document ID : adobe:docid:indd:a0782be4-c2ed-11dd-abb4-abd8137a1b16 Original Document ID : adobe:docid:indd:a0782be4-c2ed-11dd-abb4-abd8137a1b16 Rendition Class : proof:pdf Derived From Instance ID : c5e4e7c2-c2e9-11dd-abb4-abd8137a1b16 Derived From Document ID : adobe:docid:indd:c5e4e7c1-c2e9-11dd-abb4-abd8137a1b16 History Action : saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved History Instance ID : xmp.iid:9551E7979554E0118C3ACD2D37FF6F76, xmp.iid:9651E7979554E0118C3ACD2D37FF6F76, xmp.iid:9A4B22B29654E0118C3ACD2D37FF6F76, xmp.iid:A520F15BCA54E0118C3ACD2D37FF6F76, xmp.iid:4F322501CB54E0118C3ACD2D37FF6F76, xmp.iid:50322501CB54E0118C3ACD2D37FF6F76, xmp.iid:6A03C939CB54E0118C3ACD2D37FF6F76, xmp.iid:EF126C6ACC54E0118C3ACD2D37FF6F76, xmp.iid:F9CE797CCC54E0118C3ACD2D37FF6F76, xmp.iid:5E2B60A7CC54E0118C3ACD2D37FF6F76, xmp.iid:5F2B60A7CC54E0118C3ACD2D37FF6F76, xmp.iid:1A4E2F201857E011AE39D35D48B83C3F, xmp.iid:85C05963C442E111B937C9D2E283E9D3, xmp.iid:86C05963C442E111B937C9D2E283E9D3, xmp.iid:F08AAC95C742E111B937C9D2E283E9D3, xmp.iid:6037448CD242E111B937C9D2E283E9D3, xmp.iid:A443B2D5DF45E111938AD4CE3B5DAE44, xmp.iid:18C6C5F8DF45E111938AD4CE3B5DAE44, xmp.iid:01E304699537E411845DA59574533DD8, xmp.iid:445F25279637E411845DA59574533DD8 History When : 2011:03:22 10:03:49-05:00, 2011:03:22 10:03:49-05:00, 2011:03:22 10:11:43-05:00, 2011:03:22 16:21:32-05:00, 2011:03:22 16:26:09-05:00, 2011:03:22 16:26:31-05:00, 2011:03:22 16:27:44-05:00, 2011:03:22 16:36:15-05:00, 2011:03:22 16:36:45-05:00, 2011:03:22 16:37:57-05:00, 2011:03:22 16:43:59-05:00, 2011:03:25 14:43:15-05:00, 2012:01:19 11:38:24-06:00, 2012:01:19 11:38:24-06:00, 2012:01:19 12:01:17-06:00, 2012:01:19 13:19:46-06:00, 2012:01:23 10:32:26-06:00, 2012:01:23 10:33:25-06:00, 2014:09:08 15:19:17-05:00, 2014:09:08 15:24:36-05:00 History Software Agent : Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5 History Changed : /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata Create Date : 2014:09:24 15:58:26-05:00 Modify Date : 2014:09:24 15:58:26-05:00 Metadata Date : 2014:09:08 15:25:41-05:00 Creator Tool : Adobe InDesign CS5.5 (7.5) Page Image Page Number : 1, 2 Page Image Format : JPEG, JPEG Page Image Width : 256, 256 Page Image Height : 256, 256 Page Image : (Binary data 8399 bytes, use -b option to extract), (Binary data 3194 bytes, use -b option to extract) Doc Change Count : 274 Format : application/pdf Title : untitled Producer : Acrobat Distiller 10.1.7 (Windows) Trapped : False Page Count : 8 Creator : Adobe InDesign CS5.5 (7.5)EXIF Metadata provided by EXIF.tools