Medtronic 2490A CareLink Monitor Model 2490 User Manual 2490

Medtronic, Inc. CareLink Monitor Model 2490 2490

Contents

User Manual

Download: Medtronic 2490A CareLink Monitor Model 2490 User Manual 2490
Mirror Download [FCC.gov]Medtronic 2490A CareLink Monitor Model 2490 User Manual 2490
Document ID222227
Application IDmRLOn1j7S2lPHgHaWYFQmA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize36.18kB (452249 bits)
Date Submitted2002-01-23 00:00:00
Date Available2002-01-24 00:00:00
Creation Date2002-01-10 09:34:25
Producing SoftwareAcrobat Distiller 4.05 for Windows
Document Lastmod2002-01-21 16:17:50
Document Title2490.book
Document CreatorADOBEPS4.DRV Version 4.41
Document Author: botnej1

Medtronic Confidential
PtMan_mdvtldct
2490_Fc.fm 1/10/02 9:33 am
UC200200183 EN xxx release
Draft 2
CARELINK™ MONITOR
Model 2490A
HE
AR
NIT U
O E
R O
IS NLY
IN
CA
RE
LI
NK
NIT
24
90
CARELINK
Patient manual
Caution: Federal law (USA)
restricts this device to sale by or on
the order of a physician.
220548001
Rev A
Refer to the “Med/Vit_Lds_Cath”
category in doc#163256 for
Printing Instructions
2490_Fc.fm 1/10/02 9:33 am
UC200200183 EN xxx release
Draft 2
220548001
Rev A
Medtronic Confidential
PtMan_mdvtldct
Refer to the “Med/Vit_Lds_Cath”
category in doc#163256 for
Printing Instructions
Medtronic Confidential
PtMan_mdvtldct
2490TOC.fm 1/10/02 9:33
am UC200200183 EN xxx release
Draft 2
Table of contents
Introduction
When to use your
CareLink Monitor 3
When not to use your
CareLink Monitor 3
Precautions
About your CareLink Monitor 6
Choosing a place to set up your CareLink
Monitor 7
Setting up your
CareLink Monitor
Using your CareLink Monitor 12
Green status lights on your CareLink
Monitor 16
Orange status lights on your
CareLink Monitor 16
Caring for your
CareLink Monitor
18
220548001
Rev A
Refer to the “Med/Vit_Lds_Cath”
category in doc#163256 for
Printing Instructions
2490TOC.fm 1/10/02 9:33
am UC200200183 EN xxx release
Draft 2
Medtronic Confidential
PtMan_mdvtldct
ii
220548001
Rev A
Refer to the “Med/Vit_Lds_Cath”
category in doc#163256 for
Printing Instructions
Medtronic Confidential
PtMan_mdvtldct
2490.fm 1/10/02 9:33 am
UC200200183 EN xxx release
Draft 2
Introduction
This manual is intended to help you
understand and use your Medtronic® Model
2490A CareLink Monitor.
If you have any questions not answered by
this manual, or if you have any problems with
your CareLink Monitor, talk to your doctor.
Your doctor knows your medical history and
can give you the help you need.
When to use your
CareLink Monitor
The CareLink Monitor is an electronic device
that provides an easy way for your doctor to
obtain information about your implanted
device. The CareLink Monitor gathers this
information to allow your doctor to manage
your care.
Your CareLink Monitor is intended specifically
for your use only. It will not work with other
implanted devices and should only be used by
you as directed by your doctor. Unauthorized
use by others with implanted devices could
interrupt the prescribed operation of their
device.
When not to use your
CareLink Monitor
Warning: If you are feeling ill and you think
you might need to go to the hospital, seek
medical attention immediately. If there is an
emergency, call 911 or follow other
instructions from your doctor. Do not use your
220548001
Rev A
Refer to the “Med/Vit_Lds_Cath”
category in doc#163256 for
Printing Instructions
2490.fm 1/10/02 9:33 am
UC200200183 EN xxx release
Draft 2
Medtronic Confidential
PtMan_mdvtldct
CareLink Monitor to send your medical
information to your doctor unless you have
already contacted your doctor and your doctor
has requested that you use your CareLink
Monitor.
Warning: To ensure the safe operation of
your implanted device, only use the CareLink
Monitor as described in this manual and at the
times prescribed by your doctor. If you miss a
scheduled time to send data, consult with your
doctor.
Warning: If you feel ill after positioning the
antenna, remove the antenna from over your
implanted device and turn "off" your CareLink
Monitor. If you still feel ill, contact your doctor.
Warning: Your CareLink Monitor’s antenna
contains a strong magnet; however, the
monitor has been designed for use with your
implanted device. To ensure proper function of
your implanted device when not using the
monitor, avoid other strong magnets, such as
those used in some stereo speakers, bingo
wands, extractor wands, magnetic badges,
and magnetic therapy products.
Warning: To ensure proper operation of your
implanted device, always turn on the CareLink
Monitor before positioning the antenna. Follow
the instructions in this manual about
positioning the antenna over your implanted
device.
220548001
Rev A
Refer to the “Med/Vit_Lds_Cath”
category in doc#163256 for
Printing Instructions
2490.fm 1/10/02 9:33 am
UC200200183 EN xxx release
Draft 2
Medtronic Confidential
PtMan_mdvtldct
Warning: Do not use the antenna if your
CareLink Monitor does not operate as
described in “Using your CareLink Monitor” on
page 12. Check the batteries as described in
“Battery status” on page 17. If you need
further assistance, contact your clinic.
Precautions
■
■
■
■
Do not use a cellular phone while the
antenna is positioned over your implanted
device.
If possible, avoid using the telephone
while using your CareLink Monitor. Your
phone line will be "busy" while your
CareLink Monitor is sending data.
Note: In the case of an emergency, you
can use your phone to call for help. If you
have an emergency and the CareLink
Monitor is "on" (power status light is lit),
press the Power button to turn the
CareLink Monitor "off" (power status light
is not lit) and to ensure your phone line is
available.
You can use your CareLink Monitor away
from your home. However, you will need to
keep the following requirements in mind:
– If you are using a telephone line that
requires you to dial a number (usually
“9”) to make an outside call, make sure
that the telephone line settings are
correct. See “Verifying the telephone
line settings” on page 10.
Your CareLink Monitor is designed for use
in the continental United States, Alaska
and Hawaii.
220548001
Rev A
Refer to the “Med/Vit_Lds_Cath”
category in doc#163256 for
Printing Instructions
Medtronic Confidential
PtMan_mdvtldct
2490.fm 1/10/02 9:33 am
UC200200183 EN xxx release
Draft 2
About your CareLink Monitor
Carrying
Case
Antenna
Pouch
HE
AR
NIT U
O E
R O
IS NLY
NIN
CA
Phone
Plugs
RE
LI
NK
NIT
24
90
Battery
Compartment
Power
Button
CARELINK
Display
Panel
Figure 1 The CareLink Monitor
(front view, approximately 1/4 actual size)
The CareLink Monitor (Figure 1) uses an
antenna that is permanently attached to the
monitor to gather information from your
implanted device.
220548001
Rev A
Refer to the “Med/Vit_Lds_Cath”
category in doc#163256 for
Printing Instructions
Medtronic Confidential
PtMan_mdvtldct
2490.fm 1/10/02 9:33 am
UC200200183 EN xxx release
Draft 2
CARELINK MONITOR 2490A
WARNING: USE ONLY
WHEN MONITOR IS ON
Read instruction manual prior to use
Caution: This device contains a
strong magnet. Proximity to recording
tape and disks should be avoided
Figure 2 Antenna (front view, approximately
1/3 actual size)
Choosing a place to set up your
CareLink Monitor
Consider the following recommendations for
choosing a place to set up your CareLink
Monitor:
■ Put your CareLink Monitor in a place
where you can sit comfortably and see the
front of the CareLink Monitor.
■ You will need to connect your CareLink
Monitor to a telephone jack. You may use
either the telephone cord provided with
your CareLink Monitor or any telephone
cord with standard connectors.
■ Before using your CareLink Monitor, turn
off any television sets or computer
monitors that are within six feet of your
CareLink Monitor or its antenna.
220548001
Rev A
Refer to the “Med/Vit_Lds_Cath”
category in doc#163256 for
Printing Instructions
2490.fm 1/10/02 9:33 am
UC200200183 EN xxx release
Draft 2
■
■
Medtronic Confidential
PtMan_mdvtldct
The CareLink Monitor antenna contains a
very powerful magnet that may damage
electronic equipment. Do not place or
transport the antenna within six inches of
credit cards, computers, computer disks,
video tapes or other electronic equipment
or media containing a magnet strip.
Do not place your CareLink Monitor
anywhere it could get wet.
– Caution: Do not get your CareLink
Monitor wet. Water can damage your
CareLink Monitor. If your CareLink
Monitor is exposed to water, contact
your clinic for instructions.
Setting up your
CareLink Monitor
Before you use your CareLink Monitor you will
need to:
1. Install four C size batteries.
2. Verify the telephone line settings.
3. Connect your CareLink Monitor to a
telephone jack.
You may connect a telephone to your
CareLink Monitor, but the telephone is not
required for your CareLink Monitor to
work properly. You may choose to connect
your monitor to your telephone if you intend to
leave your CareLink Monitor set up
continually.
220548001
Rev A
Refer to the “Med/Vit_Lds_Cath”
category in doc#163256 for
Printing Instructions
2490.fm 1/10/02 9:33 am
UC200200183 EN xxx release
Draft 2
Medtronic Confidential
PtMan_mdvtldct
Installing batteries
Your CareLink Monitor requires four C size
batteries. To open the battery compartment,
push the latch upward.
Install the battery on each end first as shown
in Figure 3.
Battery Compartment Latch
Figure 3 Battery compartment with two
batteries installed
Figure 4 Battery compartment with four
batteries installed
Note: When you are ready to send data at
your scheduled time, press the Power button.
If the green power status light remains off or
the orange battery status light blinks and the
CareLink Monitor beeps, verify that the
batteries are installed correctly. Replace the
batteries if necessary. Follow local regulations
for the proper disposal of used batteries.
220548001
Rev A
Refer to the “Med/Vit_Lds_Cath”
category in doc#163256 for
Printing Instructions
2490.fm 1/10/02 9:33 am
UC200200183 EN xxx release
Draft 2
Medtronic Confidential
PtMan_mdvtldct
Verifying the telephone line settings
Before using your CareLink Monitor, verify
that the telephone line settings are
appropriate. There are two telephone line
settings on the CareLink Monitor. See
Figure 5.
Figure 5 Location of telephone line settings
NONE-7-8-9 determines if a number needs to
be dialed to reach an outside telephone line.
There are four positions for the switch. The
switch will click into position above each
setting as it is moved from side to side.
TONE-PULSE selects a tone or pulse
telephone line. There are two positions for the
switch. The switch will click into position above
each setting as it is moved from side to side.
Telephone line settings may be selected when
your CareLink Monitor is "on" or "off."
Select the settings that are appropriate for the
telephone line you will be using. None is the
most common setting for home use. If you are
staying in a hotel, you may have to set the
switch to "7", "8" or “9” to get an outside line.
See Figure 6. If you have questions about the
phone line, contact your local phone carrier.
10
220548001
Rev A
Refer to the “Med/Vit_Lds_Cath”
category in doc#163256 for
Printing Instructions
Medtronic Confidential
PtMan_mdvtldct
2490.fm 1/10/02 9:33 am
UC200200183 EN xxx release
Draft 2
Figure 6
Telephone line settings
Connecting your CareLink Monitor
to a telephone jack
Telephone
Not
Required
Jack
CARELINK
Figure 7 The CareLink Monitor connected to a
telephone jack and a telephone (the telephone
is not required).
To set up your CareLink Monitor, you will need
to do the following:
1. Make sure that you have your CareLink
Monitor and the telephone cord.
2. Locate the plugs on the top right corner
of your CareLink Monitor.
11
220548001
Rev A
Refer to the “Med/Vit_Lds_Cath”
category in doc#163256 for
Printing Instructions
2490.fm 1/10/02 9:33 am
UC200200183 EN xxx release
Draft 2
Medtronic Confidential
PtMan_mdvtldct
Figure 8 Telephone plugs
3. Plug one end of the telephone cord into
the Line plug on the top of your CareLink
Monitor. See Figure 8.
4. Plug the other end of the telephone cord
into the telephone jack in your wall.
5. (Not Required) For convenient use of
your CareLink Monitor or the telephone,
plug the cord from your telephone into the
Phone plug on your CareLink Monitor.
Using your CareLink Monitor
1. Press the “Power” button on the front of
your CareLink Monitor. The green light
above the Power button blinks and then
remains lit.
2. Hold the antenna over your implanted
device so that the position antenna status
light is off. You may either hold the
antenna snugly against your clothing or
hold it directly against your skin. The
label should be facing out and away from
you when you are holding the antenna
over your implanted device. See Figure 9.
Reposition the antenna if the orange
antenna position light starts blinking. See
Figure 10.
12
220548001
Rev A
Refer to the “Med/Vit_Lds_Cath”
category in doc#163256 for
Printing Instructions
2490.fm 1/10/02 9:33 am
UC200200183 EN xxx release
Draft 2
Medtronic Confidential
PtMan_mdvtldct
Note: You may hear tones from your
implanted device when the antenna is
placed in position. If you have questions
about these tones, you should talk to your
doctor. Whether your implanted device
emits tones depends on the model and
the features selected by your doctor.
Figure 9 Positioning the antenna
13
220548001
Rev A
Refer to the “Med/Vit_Lds_Cath”
category in doc#163256 for
Printing Instructions
Medtronic Confidential
PtMan_mdvtldct
2490.fm 1/10/02 9:33 am
UC200200183 EN xxx release
Draft 2
3. Watch the status lights on the display
panel on the front of your CareLink
Monitor. See Figure 10.
Power
Button
Power
Status
Light
(Green)
Reading
Status
Lights
(Green)
Sending
Status
Lights
(Green)
CARELINK
Battery
Status
Light
(Orange)
Figure 10
Antenna
Position
Status Light
(Orange)
Telephone
Line Status
Light
(Orange)
Power button and status lights
Each of these status lights has a different
meaning when you use your CareLink
Monitor to send your implanted device
information.
4. The five green reading status lights fill as
your CareLink Monitor gathers
information from your implanted device.
While the reading status lights are
blinking, remain seated and make sure
your CareLink Monitor antenna is placed
over your implanted device. When your
CareLink Monitor is done collecting data
from your implanted device, these status
lights stop blinking and turn "off." Your
CareLink Monitor beeps twice and
automatically dials the correct number.
This process typically takes less than 3
minutes, but may take up to 12 minutes.
14
220548001
Rev A
Refer to the “Med/Vit_Lds_Cath”
category in doc#163256 for
Printing Instructions
2490.fm 1/10/02 9:33 am
UC200200183 EN xxx release
Draft 2
Medtronic Confidential
PtMan_mdvtldct
When you hear your CareLink Monitor
dialing, remove the antenna from your
implanted device. Place the antenna back
in its pouch.
Note: Your CareLink Monitor will emit
high-pitched tones when dialing the preprogrammed number.
The three green sending status lights start
blinking when your CareLink Monitor is
sending data. This process typically takes
less than 3 minutes but may take up to 60
minutes.
When the CareLink Monitor is sending
data, your telephone line is not available
to make or receive calls. In case of
emergency, press the Power button to turn
"off" the monitor and to ensure your phone
line is available for incoming and outgoing
calls.
When the green sending status lights start
blinking, you can get up and leave, but you
should not use the telephone unless there
is an emergency.
When your CareLink Monitor is done
sending information, the right sending
status light remains on and you hear two
beeps.
Your CareLink Monitor shuts off
automatically after two minutes or you
may press the Power button. You can then
use the telephone to make or receive any
calls. The CareLink Monitor may be put
away for storage.
15
220548001
Rev A
Refer to the “Med/Vit_Lds_Cath”
category in doc#163256 for
Printing Instructions
2490.fm 1/10/02 9:33 am
UC200200183 EN xxx release
Draft 2
Medtronic Confidential
PtMan_mdvtldct
Note: If you must stop before the session is
complete, remove the antenna from over your
implanted device and turn "off" your CareLink
Monitor. When you are ready to re-start the
session, follow steps 1 though 4.
Green status lights on your
CareLink Monitor
The green lights indicate data reading status
and data sending status. See Figure 10.
If the reading lights stop blinking and remain lit
for more than 3 minutes, press the Power
button and repeat steps 1 through 4.
If your CareLink Monitor is turned "off" before
your data is read, repeat steps 1 through 4.
If the sending status lights remain lit for more
than 1 hour, turn "off" your CareLink Monitor
and repeat steps 1 through 4.
If your CareLink Monitor is turned "off" before
your data is sent, repeat steps 1 through 4.
Orange status lights on your
CareLink Monitor
The three orange lights on the front of your
CareLink Monitor are status lights. See
Figure 10.
The status lights are:
■ Battery Status
■ Antenna Position Status
■ Telephone Line Status
16
220548001
Rev A
Refer to the “Med/Vit_Lds_Cath”
category in doc#163256 for
Printing Instructions
2490.fm 1/10/02 9:33 am
UC200200183 EN xxx release
Draft 2
Medtronic Confidential
PtMan_mdvtldct
The orange status lights should not be lit when
you are using your CareLink Monitor. If any of
these status lights remain on or you hear short
beeps after pressing the Power button, try the
recommendations in the following paragraphs.
Battery status
If the orange battery status light blinks and
you hear continuous beeps, the batteries are
low and should be replaced. If no status lights
come on after pressing the Power button,
verify that the batteries are installed correctly.
Replace the batteries if necessary. See
“Installing batteries” on page 9.
Antenna position
If the orange antenna position status light
begins blinking and you hear short beeps:
■ Make sure the label on the top of the
antenna is facing out and away from you.
■ Reposition the antenna over your
implanted device.
When the antenna is repositioned correctly,
the orange antenna position status light will
turn "off", the green status lights will begin
blinking and your CareLink Monitor will
resume data collection.
17
220548001
Rev A
Refer to the “Med/Vit_Lds_Cath”
category in doc#163256 for
Printing Instructions
2490.fm 1/10/02 9:33 am
UC200200183 EN xxx release
Draft 2
Medtronic Confidential
PtMan_mdvtldct
Telephone line status
If your CareLink Monitor beeps and the
telephone line status blinks:
■ If the call was interrupted due to Call
Waiting, the monitor automatically redials
and sends your device information. If your
CareLink Monitor does not begin
redialing, check that the telephone
connections are intact.
■ Make sure that the telephone line settings
are correct. See Figure 6. If you need help
determining the type of telephone line,
contact your local phone carrier.
■ Test the telephone line to make sure it is
working by making an outside call using
the telephone connected to your CareLink
Monitor. If the telephone connected to
your CareLink Monitor is not working, try
another telephone that is connected to a
different telephone jack.
■ Telephone line settings may be selected
when your CareLink Monitor is "on" or
"off."
Caring for your
CareLink Monitor
Avoid dropping your CareLink Monitor on a
hard surface. Contact your clinic if your
CareLink Monitor has been dropped.
You can clean the outside with a clean, dry
cloth.
18
220548001
Rev A
Refer to the “Med/Vit_Lds_Cath”
category in doc#163256 for
Printing Instructions
2490.fm 1/10/02 9:33 am
UC200200183 EN xxx release
Draft 2
Medtronic Confidential
PtMan_mdvtldct
Caution: Do not get your CareLink Monitor
wet, because water can damage it. If your
CareLink Monitor is exposed to water, contact
your clinic for instructions.
19
220548001
Rev A
Refer to the “Med/Vit_Lds_Cath”
category in doc#163256 for
Printing Instructions
2490.fm 1/10/02 9:33 am
UC200200183 EN xxx release
Draft 2
Medtronic Confidential
PtMan_mdvtldct
20
220548001
Rev A
Refer to the “Med/Vit_Lds_Cath”
category in doc#163256 for
Printing Instructions
2490_Bc.fm 1/10/02 9:33 am
UC200200183 EN xxx release
Draft 2
220548001
Rev A
Blank For Position Only. Do Not Print!
Medtronic Confidential
PtMan_mdvtldct
Refer to the “Med/Vit_Lds_Cath”
category in doc#163256 for
Printing Instructions
2490_Bc.fm 1/10/02 9:33 am
UC200200183 EN xxx release
Draft 2
World Headquarters
Medtronic, Inc.
710 Medtronic Parkway NE
Minneapolis,
MN 55432-5604
USA
www.medtronic.com
Tel. 763-514-4000
Fax 763-514-4879
Medtronic USA, Inc.
Contact information
for patients:
Toll-free in USA
Tel.1-800-551-5544
(8 a.m. – 5 p.m. CST)
Fax 763-514-1854
Europe/Africa/Middle East
Headquarters
Medtronic Europe S.A.
Route du Molliau
1131 Tolochenaz
Switzerland
www.medtronic.co.uk
Tel. 41-21-802-7000
Fax 41-21-802-7900
Medtronic Confidential
PtMan_mdvtldct
Asia-Pacific
Medtronic Japan
Solid Square West
Tower 6F,
580 Horikawa-cho,
Saiwai-ku,
Kawasaki,
Kanagawa 210-0913
Japan
Tel. 81-44-540-6112
Fax 81-44-540-6200
Latin America
Headquarters
Medtronic, Inc.
710 Medtronic NE
Minneapolis,
MN 55432-5604
USA
Tel. 763-514-4000
Fax 763-514-4879
Canada
Medtronic of Canada Ltd.
6733 Kitimat Road
Mississauga,
Ontario L5N 1W3
Canada
Tel. 905-826-6020
Fax 905-826-6620
Toll-free in Canada:
1-800-268-5346
*220548001*
220548001
Rev A
© Medtronic, Inc. 2001
All Rights Reserved
UCX220548001 220548001
January 2002
Refer to the “Med/Vit_Lds_Cath”
category in doc#163256 for
Printing Instructions

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Create Date                     : 2002:01:10 09:34:25
Producer                        : Acrobat Distiller 4.05 for Windows
Author                          : botnej1
Creator                         : ADOBEPS4.DRV Version 4.41
Title                           : 2490.book
Modify Date                     : 2002:01:21 16:17:50-05:00
Page Count                      : 24
Page Mode                       : UseOutlines
EXIF Metadata provided by EXIF.tools
FCC ID Filing: LF52490A

Navigation menu