Medtronic 3531 Verify ENS (external neurostimulator) User Manual
Medtronic, Inc. Verify ENS (external neurostimulator)
User Manual
Filename Date Time UC200xxxxxx EN 4.625 x 6 inches (117 mm x 152 mm) VERIFYTM EXTERNAL NEUROSTIMULATOR Medtronic Confidential ImplantManual.xsl - IPGTemplate.fm Template version: 12-13-2011 3531 User manual ! USA M943581A001 Rx only Rev X 2013-03 Filename Date Time UC200xxxxxx EN 4.625 x 6 inches (117 mm x 152 mm) M943581A001 Rev X Medtronic Confidential ImplantManual.xsl - IPGTemplate.fm Template version: 12-13-2011 2013-03 Filename Date Time UC200xxxxxx EN 4.625 x 6 inches (117 mm x 152 mm) Medtronic Confidential ImplantManual.xsl - IPGTemplate.fm Template version: 12-13-2011 Explanation of symbols on product or package labeling Refer to the appropriate product for symbols that apply. Conformité Européenne (European Conformity). This symbol means that the device fully complies with MDD 93/42/EEC (NB 0123) and R&TTE Directive 1999/5/EC. System meets the applicable Canadian (CAN/CSA-C22.2 No. 60601-1) electrical safety standard requirements. Do not reuse Consult instructions for use Serial number Manufacturer EC REP Authorized representative in the European community IEC60601-1/EN60601-1, Type BF equipment Non-ionizing electromagnetic radiation -XX °C -XX °F XX °C XXX °F Temperature limitation For USA audiences only Do not dispose of this product in the unsorted municipal waste stream. Dispose of this product according to local regulations. See http://recycling.medtronic.com for instructions on proper disposal of this product. Chinese Standard (SJ/T11364-2006) Logo: Electronic Information Products Pollution Control Symbol. (The date in this logo means the environmental protection use period of the product.) 2013-03 M943581A001 Rev X English 2013-03 Filename Date Time UC200xxxxxx EN 4.625 x 6 inches (117 mm x 152 mm) Medtronic Confidential ImplantManual.xsl - IPGTemplate.fm Template version: 12-13-2011 Medtronic® is a trademark of Medtronic, Inc., registered in the U.S. and other countries. VerifyTM is a trademark of Medtronic, Inc. Bluetooth® is a registered trademark of Bluetooth SIG, Inc. ! USA FCC Information The following is communications regulation information on the Model 3531 External Neurostimulator. FCC ID: LF53531 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. IMPORTANT: Changes or modifications to this product not authorized by Medtronic, Inc., could void the FCC Certification and negate your authority to operate this product. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. English 2013-03 2013-03 M943581A001 Rev X Filename Date Time UC200xxxxxx EN 4.625 x 6 inches (117 mm x 152 mm) Medtronic Confidential ImplantManual.xsl - IPGTemplate.fm Template version: 12-13-2011 Table of contents Purpose of the device 5 Description 5 Package contents 5 Device specifications 5 Declaration of Conformity 8 Instructions for use 9 Pairing the external neurostimulator to the controller 9 Using the external neurostimulator during test stimulation 9 Replacing the external neurostimulator batteries 10 Using the external neurostimulator boot 12 Using the external neurostimulator belt 13 Device care and storage 15 Safety and technical checks 15 Refer to the indications sheet for indications and related information. Refer to the appropriate information for prescribers booklet for contraindications, warnings, precautions, adverse events summary, individualization of treatment, patient selection, use in specific populations, resterilization, and component disposal. Refer to the Test stimulation lead implant manual packaged with the test stimulation lead for test stimulation-specific contraindications, warnings, precautions, adverse events summary, individualization of treatment, patient selection, use in specific populations, resterilization, and component disposal. Refer to System Eligibility, Battery Longevity, Specifications reference manual for neurostimulator selection, battery longevity calculations and specific neurostimulator specifications. ! USA Refer to the clinical summary booklet for information on the clinical study results of the neurostimulation system and individualization of treatment. 2013-03 M943581A001 Rev X English 2013-03 Filename Date Time UC200xxxxxx EN 4.625 x 6 inches (117 mm x 152 mm) English 2013-03 Medtronic Confidential ImplantManual.xsl - IPGTemplate.fm Template version: 12-13-2011 2013-03 M943581A001 Rev X Filename Date Time UC200xxxxxx EN 4.625 x 6 inches (117 mm x 152 mm) Medtronic Confidential ImplantManual.xsl - IPGTemplate.fm Template version: 12-13-2011 Purpose of the device The Medtronic Model 3531 Verify External Neurostimulator (ENS) is used to evaluate a Medtronic Sacral Neuromodulation (SNM) System during lead placement or test stimulation. Description The Medtronic Model 3531 External Neurostimulator is a disposable, single-use device equipped with Bluetooth wireless technology, and is part of a sacral neuromodulation system. Package contents ▪ ▪ ▪ ▪ ▪ External neurostimulator External neurostimulator boot AAAA alkaline batteries (4) Product literature ! USA Warranty card Device specifications The external neurostimulator (Figure 1) is a programmable device that delivers stimulation through one or more leads (delivered through one lead at a time). The stimulation settings are stored in programs. A program is a specific combination of pulse width, rate, and amplitude settings acting on a specific electrode combination. 2013-03 M943581A001 Rev X English 2013-03 Filename Date Time UC200xxxxxx EN 4.625 x 6 inches (117 mm x 152 mm) Medtronic Confidential ImplantManual.xsl - IPGTemplate.fm Template version: 12-13-2011 Light-emitting diode (LED) ENS button Output jack Figure 1. Model 3531 External Neurostimulator. Table 1. Operating values for the Model 3531 External Neurostimulatora Programmable parameter Operating values and rangesb Number of programs 1 to 3 Electrode configuration 1 to 4 electrodes as anode, cathode, or off Amplitude 0 to 12.5 mA with 0.1-mA resolution Amplitude – upper patient limit Programmed value to 12.5 mA (same resolution as amplitude) Amplitude – lower patient limit 0 mA to the programmed value (same resolution as amplitude) Pulse width 60 to 450 µs (10-µs resolution) Rate 3 to 130 Hz (1-Hz resolution between 3 and 30 Hz; 5-Hz resolution between 30 and 130 Hz) Selection of parameters and values is limited by the controller with regards to appropriate applications, therapies, and devices. Out-of-regulation detection may prevent the use of some parameter combinations. Table 2. Physical characteristics of the Model 3531 External Neurostimulatora Description Value Length 51 mm (2.0 in) Length, including cable connector 58 mm (2.3 in) English 2013-03 2013-03 M943581A001 Rev X Filename Date Time UC200xxxxxx EN 4.625 x 6 inches (117 mm x 152 mm) Medtronic Confidential ImplantManual.xsl - IPGTemplate.fm Template version: 12-13-2011 Table 2. Physical characteristics of the Model 3531 External Neurostimulatora (continued) Description Value Width 43 mm (1.7 in) Thickness 15 mm (0.6 in) Weight (with batteries) 53.9 g (1.9 oz) Output jack 21 pin Identification code NLM All measurements are approximate. Table 3. Electrical and physical characteristics for the Model 3531 External Neurostimulator Value Description Power source AAAA alkaline batteries (2) Battery life 14 days minimum for alkaline batteriesa Operating type Continuous Degree of protection against electrical shock Type BF Degree of protection against fluid ingress IP24b Case material Polycarbonate/ABS blend plastic resin Automatic shut offc Connector cable disconnected Battery life is based on 24-hour per day stimulation using 1 program: impedance = 1200 Ω, amplitude = 4.2 mA, pulse width = 210 µs, rate = 14 Hz, and multiple communications between the controller and the external neurostimulator. The ENS device, with cable fully inserted and battery door side protected either by the device being bandaged directly to the skin or by having the device in the boot or belt, meets the IP24 classification for particulate and water exposure resistance. IP classification is IPN1N2, where: N1 is 2 = protection of equipment against a solid foreign objects ≥ 12.5 mm diameter and N2 is 4 = protection of equipment against ingress of water with harmful effects of splashing. Use the controller to turn the external neurostimulator on once the condition is resolved. 2013-03 M943581A001 Rev X English 2013-03 Filename Date Time UC200xxxxxx EN 4.625 x 6 inches (117 mm x 152 mm) Medtronic Confidential ImplantManual.xsl - IPGTemplate.fm Template version: 12-13-2011 Table 4. Storage, shipping, and operating conditions for the Model 3531 External Neurostimulator Parameter Storage Shipping Operating Minimum temperature Room temperature -35 °C (-31 °F) 9 °C (49 °F) Maximum temperature Room temperature 57 °C (135 °F) 43 °C (110 °F) Maximum humidity — 95% (noncondensing)a 95% (noncondensing)b Minimum atmospheric pressure — — 50 kPa Maximum atmospheric pressure — — 106 kPa Tested at 30 °C (86 °F). Not tested at the maximum temperature. Tested at 35 °C (95 °F). Not tested at the maximum temperature. Declaration of Conformity Medtronic declares that this product is in conformity with the essential requirements of Directive 1999/5/EC on Radio and Telecommunications Terminal Equipment and Directive 93/42/EEC on Medical Devices. For additional information, contact the appropriate Medtronic representative listed on the inside back cover of this manual. English 2013-03 2013-03 M943581A001 Rev X Filename Date Time UC200xxxxxx EN 4.625 x 6 inches (117 mm x 152 mm) Medtronic Confidential ImplantManual.xsl - IPGTemplate.fm Template version: 12-13-2011 Instructions for use The external neurostimulator is used to evaluate lead placement and stimulation settings. w Warning: This device was designed for single patient use only. Do not reuse, reprocess, or resterilize this product. Reuse, reprocessing, or resterilization may compromise the structural integrity of the device and/or create a risk of contamination of the device, which could result in patient injury, illness, or death. # Caution: The device is not certified for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide. The consequences of using the device near flammable atmospheres are unknown. # Caution: Do not modify this equipment. Modification of this equipment can result in damage to the device, causing the device to malfunction or become unusable. # Caution: Do not use the device in the proximity of equipment that generates electromagnetic interference (EMI). EMI may cause a disruption in device function. Examples of common medical sources of EMI are magnetic resonance imaging (MRI) and lithotripsy. Powerful computer monitors, cell phones, x-ray equipment, and other monitoring equipment may also generate EMI. Note: Turn off and dispose of the external neurostimulator after defibrillation. For more information on the effects of defibrillation on the neurostimulator, refer to the Information for Prescribers Booklet. Pairing the external neurostimulator to the controller For instructions on pairing the external neurostimulator to the controller, refer to the appropriate controller programming guide. Using the external neurostimulator during test stimulation When programming during test stimulation, keep the controller within 3 meters (10 feet) of the external neurostimulator. The external neurostimulator does not attach to the controller. Using the ENS button The ENS button is used to place the external neurostimulator into discovery mode to establish communication with a controller. It can also be used when you need to immediately turn off the external neurostimulator. You must use the controller to turn on the external neurostimulator. The ENS button is not an on/off control. Press and hold the ENS button for at least three seconds to turn off the external neurostimulator or to place the external neurostimulator into discovery mode. Understanding the LED on the external neurostimulator Once batteries are inserted into the external neurostimulator, the external neurostimulator turns on, and the light-emitting diode (LED) shines continuously for a few seconds. When the LED begins to blink, the external neurostimulator has completed initiation, has entered discovery mode, and can be paired to a controller. 2013-03 M943581A001 Rev X English 2013-03 Filename Date Time UC200xxxxxx EN 4.625 x 6 inches (117 mm x 152 mm) Medtronic Confidential ImplantManual.xsl - IPGTemplate.fm Template version: 12-13-2011 Notes: ▪ The external neurostimulator will remain in discovery mode for 90 seconds, or until it successfully pairs with a controller, at which point the LED will stop blinking and turn off. ▪ The LED blinks whenever the external neurostimulator is in discovery mode, or when it receives data from a controller. ▪ Refer to the appropriate programming guide for more information on using the controller. Replacing the external neurostimulator batteries For instructions on checking the external neurostimulator batteries using the controller, refer to the appropriate controller programming guide. # Caution: Do not leave depleted batteries in the external neurostimulator. The batteries may corrode and cause damage to the electronic components. # Caution: If the device will not be used for several weeks, remove the batteries from the device. A battery left in the device may corrode, causing damage to the electronic components. Notes: ▪ Before inserting batteries, check for signs of battery leakage. If any residue is present, do not use. ▪ Stimulation settings may not reflect programming changes that were made prior to replacing the batteries. 1. If the external neurostimulator is on, use the programmer to turn the external neurostimulator off. 2. If the connector cable is attached to the external neurostimulator, disconnect the cable. 3. If the external neurostimulator is in the external neurostimulator belt or boot, remove the external neurostimulator from the belt or boot. 4. Press down lightly on the battery compartment cover, slide the cover outward, then remove the cover (Figure 2). 10 English 2013-03 2013-03 M943581A001 Rev X Filename Date Time UC200xxxxxx EN 4.625 x 6 inches (117 mm x 152 mm) Medtronic Confidential ImplantManual.xsl - IPGTemplate.fm Template version: 12-13-2011 Figure 2. Removing battery cover. 5. Remove the depleted batteries, and insert new batteries. Correct battery polarity is indicated inside the battery compartment (Figure 3). Note: For optimal performance, use the same AAAA alkaline batteries as those supplied by Medtronic. Figure 3. Inserting new batteries. 6. Replace the battery compartment cover, then slide the cover inward until it snaps into place (Figure 4). 2013-03 M943581A001 Rev X English 11 2013-03 Filename Date Time UC200xxxxxx EN 4.625 x 6 inches (117 mm x 152 mm) Medtronic Confidential ImplantManual.xsl - IPGTemplate.fm Template version: 12-13-2011 Figure 4. Replacing battery cover. Notes: ▪ After the batteries are installed and the battery compartment cover is closed, the external neurostimulator may take up to 6 seconds for device initiation. Stimulation is not available until device initiation is complete. ▪ Dispose of depleted batteries according to local requirements. 7. Use the controller to turn stimulation on. For instructions on using the controller to program the external neurostimulator, refer to the Medtronic Clinician Programming Guide packaged with the controller. Using the external neurostimulator boot The external neurostimulator boot is a single-use accessory. The external neurostimulator boot is attached to an adhesive pad, which can be used to adhere the external neurostimulator to the patient's body. Note: Schedule a visit during the test stimulation phase to replace the initial boot with a new boot. 1. Ensure that no cable is attached to the external neurostimulator. The external neurostimulator can not be inserted into the boot with a cable attached. 2. Insert the external neurostimulator into the boot (Figure 5). 12 English 2013-03 2013-03 M943581A001 Rev X Filename Date Time UC200xxxxxx EN 4.625 x 6 inches (117 mm x 152 mm) Medtronic Confidential ImplantManual.xsl - IPGTemplate.fm Template version: 12-13-2011 Figure 5. Inserting external neurostimulator into boot. 3. Clean the patient's skin, if necessary, at the location where the external neurostimulator boot is to be placed. 4. Peel off the adhesive backing of the adhesive pad and apply the external neurostimulator boot to the patient's skin. Press firmly to ensure complete contact and adhesion. Notes: ▪ If adhesive is dry or does adhere to the patient's skin, discard the boot and use a different boot. ▪ The external neurostimulator belt cannot be used with the external neurostimulator boot. Using the external neurostimulator belt The external neurostimulator belt is a single-use device that can be used to hold the external neurostimulator near the patient's body. 1. Insert the external neurostimulator, with cable attached, into the pouch on the external neurostimulator belt and snap the pouch closed (Figure 6). 2013-03 M943581A001 Rev X English 13 2013-03 Filename Date Time UC200xxxxxx EN 4.625 x 6 inches (117 mm x 152 mm) Medtronic Confidential ImplantManual.xsl - IPGTemplate.fm Template version: 12-13-2011 Figure 6. Inserting external neurostimulator into belt. Note: Leave enough slack in the cable to allow the patient to adjust or move the belt as needed without causing additional strain on the connections. 2. Coil and place any excess cable length into the pouch of the external neurostimulator belt. 3. Fasten the external neurostimulator belt around the patient’s waist. Note: The belt can be adjusted for patient comfort and fit. 14 English 2013-03 2013-03 M943581A001 Rev X Filename Date Time UC200xxxxxx EN 4.625 x 6 inches (117 mm x 152 mm) Medtronic Confidential ImplantManual.xsl - IPGTemplate.fm Template version: 12-13-2011 Device care and storage ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ Keep new batteries available. For optimal performance, use the same AAAA alkaline batteries as those supplied by Medtronic. Use the controller to check the external neurostimulator battery level daily. For instruction on using the controller, refer to the Medtronic Clinician Programming Guide packaged with the controller. Replace low or depleted batteries. Handle the device and system components with care. Do not drop, strike or step on the device. Do not dismantle or tamper with the device or system components. Clean the outside of the device with a damp cloth when necessary. Mild household cleaners will not damage the device or labels. Store the external neurostimulator at room temperature. Avoid extreme hot or cold temperatures and direct sunlight. The device and system components are not waterproof. Do not allow moisture to get inside the device or system components. With the patient cable connected, the external neurostimulator is water-resistant, but is not waterproof. Sponge baths are acceptable. Dispose of depleted batteries and devices according to local requirements. Safety and technical checks Periodic safety and technical checks or periodic maintenance of the external neurostimulator are not required. The external neurostimulator contains no serviceable components. If the external neurostimulator requires repair or is nonfunctional, send it to the appropriate address. USA Medtronic, Inc. Neurological Division MS N600 PO Box 1250 Minneapolis, MN 55440-9087 Europe, Africa, Middle East, and Asia-Pacific countries Medtronic EOC Medical Equipment Service Europe Earl Bakkenstraat 10 6422 PJ Heerlen The Netherlands Tel. 31-455664880 Fax 31-455668028 2013-03 M943581A001 Rev X English 15 2013-03 Filename Date Time UC200xxxxxx EN 4.625 x 6 inches (117 mm x 152 mm) Medtronic Confidential ImplantManual.xsl - IPGTemplate.fm Template version: 12-13-2011 Contacts: Asia: Medtronic International Ltd. Tel. 02919-1362 Fax 02907-3998 Medtronic Asia Ltd. Tel. (02)-548-1148 Fax (02)-518-4786 Australia: Medtronic Australasia Pty. Ltd. 97 Waterloo Road North Ryde, NSW 2113 Australia Tel. +61-2-9857-9000 Fax +61-2-9878-5100 Toll free 1-800-668-6700 Austria: Medtronic Österreich GmbH Tel. 01-240440 Fax 01-24044-100 Belgium: Medtronic Belgium S.A. Tel. 02-456-0900 Fax 02-460-2667 Canada: Medtronic of Canada Ltd. Tel. (1-905)-460-3800 Fax (1905)-826-6620 Czech Republic: Medtronic Czechia s.r.o. Tel. 2-965-795-80 Fax 2-965-795-89 Denmark: Medtronic Danmark A/S Tel. 45-32-48-18-00 Fax 45-32-48-18-01 Finland: Medtronic Finland Oy/LTD Tel. (09)-755-2500 Fax (09)-755-25018 France: Medtronic France S.A.S. Tel. 01-5538-1700 Fax 01-5538-1800 Germany: Medtronic GmbH Tel. (02159)-81490 Fax (02159)-8149100 Greece: Medtronic Hellas S.A. Tel. 210-67-79-099 Fax 210-67-79-399 2013-03 Hungary: Medtronic Hungária Kft. Tel. 1-889-06-00 Fax 1-889-06-99 Ireland: Medtronic Ireland Ltd. Tel. (01)-890-6522 Fax (01)-890-7220 Italy: Medtronic Italia SpA Tel. 02-241371 Fax 02-241381 Tel. 06-328141 Fax 06-3215812 Japan: Medtronic Japan Tel. 03-6430-2016 Fax 03-6430-7110 Latin America: Medtronic, Inc. Tel. (1305)-500-9328 Fax (1786)-709-4244 Norway: Medtronic Norge AS Tel. 067-10-32-00 Fax 067-10-32-10 Poland: Medtronic Poland Sp. z.o.o. Tel. (022)-465-69-00 Fax (022)-465-69-17 Portugal: Medtronic Portugal, Lda. Tel. 21-724-5100 Fax 21-724-5199 Russia: Medtronic Russia Tel. (8495) 580-7377 Fax (8495) 580-7378 Slovakia Medtronic Slovakia, o.z. Tel. 0268 206 911 Fax 0268 206 999 Spain: Medtronic Ibérica, S.A. Tel. 91-625-0400 Fax 91-650-7410 Sweden: Medtronic AB Tel. 08-568-585-00 Fax 08-568-585-01 M943581A001 Rev X Filename Date Time UC200xxxxxx EN 4.625 x 6 inches (117 mm x 152 mm) Switzerland: Medtronic (Schweiz) AG Tel. 031-868-0100 Fax 031-868-0199 The Netherlands: Medtronic B.V. Tel. (045)-566-8000 Fax (045)-566-8668 U.K.: Medtronic U.K. Ltd. Tel. 01923-212213 Fax 01923-241004 M943581A001 Rev X Medtronic Confidential ImplantManual.xsl - IPGTemplate.fm Template version: 12-13-2011 USA: Medtronic, Inc. Tel. (1763)-505-5000 Fax (1763)-505-1000 Toll-free: (1-800)-328-0810 2013-03 Filename Date Time UC200xxxxxx EN 4.625 x 6 inches (117 mm x 152 mm) Medtronic Confidential ImplantManual.xsl - IPGTemplate.fm Template version: 12-13-2011 Manufacturer Medtronic, Inc. 710 Medtronic Parkway Minneapolis, MN 55432-5604 USA www.medtronic.com Tel. +1-763-505-5000 Fax +1-763-505-1000 Authorized Representative in the European Community Medtronic B.V. Earl Bakkenstraat 10 6422 PJ Heerlen The Netherlands Tel. +31-45-566-8000 Fax +31-45-566-8668 EC REP Europe/Africa/Middle East Headquarters Medtronic International Trading Sàrl Route du Molliau 31 Case Postale 84 CH-1131 Tolochenaz Switzerland www.medtronic.eu Tel. +41-21-802-7000 Fax +41-21-802-7900 Asia-Pacific Medtronic International Ltd. Suite 1106-11 16/F, Tower 1, The Gateway 25 Canton Road, Tsimshatsui Kowloon Hong Kong Tel. +852-2919-1362 Fax +852-2907-3998 Contacts for specific countries are listed inside this cover. *M943581A001* 2013-03 © Medtronic, Inc. 2013 All Rights Reserved M943581A001 M943581A001 Rev X
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Author : kamess1 Create Date : 2012:03:28 16:02:04-05:00 Modify Date : 2012:03:28 16:03:12-05:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Format : application/pdf Creator : kamess1 Title : Creator Tool : XSL Formatter V4.2 MR5 (4,2,2008,0229) for Windows Metadata Date : 2012:03:28 16:03:12-05:00 Producer : Acrobat Distiller 10.0.0 (Windows) Document ID : uuid:c71dbbfc-5067-4dd9-ab59-d42025446d06 Instance ID : uuid:1c857a1b-52c6-495d-80a9-22024bead353 Page Mode : UseOutlines Page Count : 20EXIF Metadata provided by EXIF.tools