Melange Systems Private TARANG-P20 Tarang-P20 User Manual Tarang P20 Prodict Manual
Melange Systems Private Limited Tarang-P20 Tarang P20 Prodict Manual
Manual
Melange Systems Private Limited Wiireless controols in actionn Ta arang g P™ ™ Pro oduct Manu M ual Mellange Sys stems Prrivate Lim mited, #4/ /1, 7th Crross, Kum mara Parrk West, Ban ngalore 560 020 P: +91 80 23561023 3, 23462 2175 info o@melan ngesystem ms.com Table of Contents 1. Tarang-P20 FCC Compliance ------------------------------------------------------------------------------------------- 3 2. Tarang-P series -------------------------------------------------------------------------------------------------------------- 5 2.1 Features --------------------------------------------------------------------------------------------------------------------- 5 3. Tarang P20 -------------------------------------------------------------------------------------------------------------------- 6 3.1 Specifications --------------------------------------------------------------------------------------------------------------- 6 3.2 Mechanical Drawings ----------------------------------------------------------------------------------------------------- 7 4. Interface ----------------------------------------------------------------------------------------------------------------------- 8 4.1 Interfacing with microcontroller --------------------------------------------------------------------------------------- 9 5. Table of AT Commands ------------------------------------------------------------------------------------------------- 10 5.1 Table of General AT Commands ------------------------------------------------------------------------------------- 10 6. Updating Firmware ------------------------------------------------------------------------------------------------------- 11 6.1 Software erase of code ------------------------------------------------------------------------------------------------ 11 6.2 To Hardware Erase of the module ---------------------------------------------------------------------------------- 11 6.3 Steps to load the firmware-------------------------------------------------------------------------------------------- 12 7. Placement Guidelines --------------------------------------------------------------------------------------------------- 16 8. Contact Details------------------------------------------------------------------------------------------------------------- 17 Tarang P User Manual Page 2 of 17 1. Tarang-P20 FCC Compliance This device complies with Part 15 of the FCC rules. Operation is subject to following two conditions: 1. This device may not cause harmful interference and 2. This device must accept any interference received including interference that may cause undesired operation of this device. The changes or modifications not expressly approved by the party responsible for Compliance could void the user’s authority to operate the equipment. To comply with the FCC RF exposure compliance requirements, this device and its antenna must not be co-located or operating to conjunction with any other antenna or transmitter, except if installed in compliance with FCC Multi Transmitter procedures. To inherit the modular approval, the antennas for this transmitter must be installed to provide a separation distance of 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. To OEM Installer: 1. The Original Equipment Manufacturer (OEM) must ensure that FCC labeling requirements are met. This includes a clearly visible label on the outside of the OEM enclosure specifying "Contains FCC ID: N3YTARANG-P20” or “Contains transmitter Module FCC ID: N3Y-TARANG-P20”. 2. In the user manual, final system integrator must ensure that there is no instruction provided to install or remove the transmitter module. 3. Transmitter module must be installed and used in strict accordance with the Manufacturer’s instructions as described in the user documentation that comes with the product. The user manual of the final host system must contain the following statements: This device complies with Part 15 of the FCC rules. Operation is subject to following two conditions: 1. This device may not cause harmful interference and Tarang P User Manual Page 3 of 17 2. This device must accept any interference received including interference that may cause undesired operation of this device. The changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. To comply with the FCC RF exposure compliance requirements, this device and its antenna must not be co-located or operating to conjunction with any other antenna or transmitter, except if installed in compliance with FCC Multi Transmitter procedures. To inherit the modular approval, the antennas for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Note: The buyer of the module who will incorporate this module into his host must submit the final product to the manufacturer of the module and the MANUFACTURER OF THE MODULE WILL VERIFY that the product is incorporated in host equipment in a way that is represented by the testing as shown in the test report. Tarang P User Manual Page 4 of 17 2. Tarang-P series Tarang-P series modules are designed with low to medium transmit power and for high reliability wireless networks. The modules require minimal power and provide reliable delivery of data between devices. The interfaces provided with the module help to directly fit into many industrial applications. The modules operate within the ISM 2.4-2.4835 GHz frequency band with IEEE 802.15.4 baseband. 2.1 Features • ZigBee® Pro Complaint platform. • Direct Sequence Spread Spectrum. • RF Data rate: 250 kbps. • Acknowledgement mode communication with retries. Tarang P User Manual Page 5 of 17 3. Tarang P20 3.1 Specifications Power Supply Voltage (VCC) 3.3 to 3.6V Transmit Current 165 mA (typical) Idle/Receive Current 35mA Power-down Current <60µA General Operating Frequency ISM 2.4 GHz Transmit Power Output 19dbm (typical) RF Data Rate 250 Kbps Receiver Sensitivity -105 dBm Serial Interface Data Rate 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 baud Operating Temperature -40 to 85 degree C Antenna Options Wire Antenna Network Supported Network Topologies Mesh/Star Number of Channels 15 Direct Sequence Channels Addressing Options PAN ID, Channel and Address Tarang P User Manual Page 6 of 17 3.2 Mechanical Drawings Tarang P User Manual Page 7 of 17 4. Interface The Tarang modules interface to a host device through a logic-level asynchronous serial port. Through its serial port, the module can communicate with any logic and voltage compatible UART or through a level translator to any serial device (For example: RS-232 or USB interface board). Tarang can be interface with a micro controller or a PC using serial port with the help of appropriate level conversion. Tarang supports serial data with, • Flow Control : None • Parity : None • Baud Rates : 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 • Data Bits : 8 Tarang P User Manual Page 8 of 17 To establish a successful serial communication with the module, serial parameters need to be configured properly in the module and host side. Both the module and PC settings can be viewed and set using AT command set through popular terminal applications like ‘HyperTerminal’. 4.1 Interfacing with microcontroller Tarang P User Manual Page 9 of 17 5. Table of AT Commands Tarang module expects numerical values in Hexadecimal. All AT commands used by Tarang modules are sorted by category. Tarang modules can be configured back to factory settings with a single command ‘ATGRD’. 5.1 Table of General AT Commands AT Command GRD GWR GER GEX Description Parameter and Range Default Value 0x00 - 0x0E Restore Defaults: Module will be configured to factory settings Write: Stores the set parameters to flash Erase: Software flash erase of the module Exit: Exit from command mode NCH Channel: Read the channel number used for communication 0 - 1200 1 - 2400 2 - 4800 SBD Interface data rate: Read / Set the serial interface data rate for the module 0x00 - 0x07 3 - 9600 0x03 4 - 19200 5 - 38400 6 - 57600 7 - 115200 Tarang P User Manual Page 10 of 17 6. Updating Firmware 6.1 Software erase of code +++ OK ATGER OK ATGEX EXIT 6.2 To Hardware Erase of the module 1. Connect the pad below the pin 11 (on the shield side) of the module to 3.3V (preferably on the LM117 output). 2. Plug the module into the interface board and power it ON for few seconds. The RX LED on the interface board should light ON continuously. 3. Power OFF the module. 4. Remove the wire connection between the pad and the 3.3v source. The module is now ready to be loaded with new code. Tarang P User Manual Page 11 of 17 6.3 Steps s to load the e firmware 1. Open the MTM M Codeloader application which has been provided to o you. 2. Choose the pro oper com porrt, where the module is con nnected. Tarang P User Manuall Page 12 of 17 3. Choose the pro oper com porrt, where the module is con nnected. ng-P Series” in n the Module Type. 4. Choose “Taran 5. Lo ocate the firm mware to be lo oaded using browse option Tarang P User Manuall Page 13 of 17 6. Prress F4 or clicck on the Run n button, you should see a console wind dow as shown n below. Tarang P User Manuall Page 14 of 17 ding the windo ows gets closed automatically, and give e a reset to th he module to start working g. After load Tarang P User Manuall Page 15 of 17 7. Placement Guidelines For obtaining the best possible range, the following guidelines must be adhered to while using Tarang modules. 1. It is important to ensure that the antennas (chip or wire) on the modules “see” open space around them. Hence the modules must be mounted in such a way that there are no blocking obstacles immediately next to the antennas. The modules must never be put inside a metallic enclosure unless an external antenna is being connected to the module. The modules must not be placed too close to a wall, table or metallic surfaces. 2. The modules must be placed as high as possible from the ground. 3. Polarization of the antennas must be the same at both sides of the link. For modules with chip antennas, the mounting should be such that the axes of the modules are parallel to each other. For wire antenna modules, the modules must be mounted such that the wires are parallel. 4. As far as possible, obstacles should be avoided in the communication path between the modules. Metallic objects and concrete walls produce a lot of attenuation and these must be avoided to the extent possible. Tarang P User Manual Page 16 of 17 8. Contact Details Melange Systems Private Limited, #4/1, 7th Cross, Kumara Park West, Bangalore- 560 020, India. Ph: +91-80-23462175/23561023 Email: info@melangesystems.com Web: http://www.melangesystems.com Copyright Melange Systems Pvt. Ltd. 2011. Tarang P User Manual Page 17 of 17
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Page Count : 17 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:e7a35399-562b-49d6-a958-5987b946e0fd Producer : Acrobat Distiller 6.0 (Windows) Create Date : 2012:06:12 15:26:57+05:30 Creator Tool : PScript5.dll Version 5.2 Modify Date : 2012:06:12 15:26:57+05:30 Document ID : uuid:3e989389-08e9-4097-bfac-6c1cb182ba42 Format : application/pdf Title : Microsoft Word - Tarang-P20 Prodict Manual Creator : KVR Author : KVREXIF Metadata provided by EXIF.tools