Melange Systems Private TARANG-P20 Tarang-P20 User Manual Tarang P20 Prodict Manual

Melange Systems Private Limited Tarang-P20 Tarang P20 Prodict Manual

Manual

Download: Melange Systems Private TARANG-P20 Tarang-P20 User Manual Tarang P20 Prodict Manual
Mirror Download [FCC.gov]Melange Systems Private TARANG-P20 Tarang-P20 User Manual Tarang P20 Prodict Manual
Document ID1723546
Application IDL53JeBZI6NamykFNGptRNw==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize124.55kB (1556928 bits)
Date Submitted2012-06-15 00:00:00
Date Available2012-06-18 00:00:00
Creation Date2012-06-12 15:26:57
Producing SoftwareAcrobat Distiller 6.0 (Windows)
Document Lastmod2012-06-12 15:26:57
Document TitleMicrosoft Word - Tarang-P20 Prodict Manual
Document CreatorPScript5.dll Version 5.2
Document Author: KVR

Melange
Systems
Private
Limited
Wiireless controols in actionn
Ta
arang
g P™
™
Pro
oduct Manu
M ual
Mellange Sys
stems Prrivate Lim
mited,
#4/
/1, 7th Crross,
Kum
mara Parrk West,
Ban
ngalore 560
020
P: +91
80 23561023
3, 23462
2175
info
o@melan
ngesystem
ms.com
Table of Contents
1. Tarang-P20 FCC Compliance ------------------------------------------------------------------------------------------- 3
2. Tarang-P series -------------------------------------------------------------------------------------------------------------- 5
2.1 Features --------------------------------------------------------------------------------------------------------------------- 5
3. Tarang P20 -------------------------------------------------------------------------------------------------------------------- 6
3.1 Specifications --------------------------------------------------------------------------------------------------------------- 6
3.2 Mechanical Drawings ----------------------------------------------------------------------------------------------------- 7
4. Interface ----------------------------------------------------------------------------------------------------------------------- 8
4.1 Interfacing with microcontroller --------------------------------------------------------------------------------------- 9
5. Table of AT Commands ------------------------------------------------------------------------------------------------- 10
5.1 Table of General AT Commands ------------------------------------------------------------------------------------- 10
6. Updating Firmware ------------------------------------------------------------------------------------------------------- 11
6.1 Software erase of code ------------------------------------------------------------------------------------------------ 11
6.2 To Hardware Erase of the module ---------------------------------------------------------------------------------- 11
6.3 Steps to load the firmware-------------------------------------------------------------------------------------------- 12
7. Placement Guidelines --------------------------------------------------------------------------------------------------- 16
8. Contact Details------------------------------------------------------------------------------------------------------------- 17
Tarang P User Manual
Page 2 of 17
1. Tarang-P20 FCC Compliance
This device complies with Part 15 of the FCC rules. Operation is subject to following two conditions:
1. This device may not cause harmful interference and
2. This device must accept any interference received including interference that may cause undesired
operation of this device.
The changes or modifications not expressly approved by the party responsible for Compliance could void
the user’s authority to operate the equipment.
To comply with the FCC RF exposure compliance requirements, this device and its antenna must not be
co-located or operating to conjunction with any other antenna or transmitter, except if installed in
compliance with FCC Multi Transmitter procedures.
To inherit the modular approval, the antennas for this transmitter must be installed to provide a
separation distance of 20cm from all persons and must not be co-located or operating in conjunction with
any other antenna or transmitter.
To OEM Installer:
1. The Original Equipment Manufacturer (OEM) must ensure that FCC labeling requirements are met. This
includes a clearly visible label on the outside of the OEM enclosure specifying "Contains FCC ID: N3YTARANG-P20” or “Contains transmitter Module FCC ID: N3Y-TARANG-P20”.
2. In the user manual, final system integrator must ensure that there is no instruction provided to install
or remove the transmitter module.
3. Transmitter module must be installed and used in strict accordance with the Manufacturer’s
instructions as described in the user documentation that comes with the product.
The user manual of the final host system must contain the following statements:
This device complies with Part 15 of the FCC rules. Operation is subject to following two conditions:
1. This device may not cause harmful interference and
Tarang P User Manual
Page 3 of 17
2. This device must accept any interference received including interference that may cause undesired
operation of this device.
The changes or modifications not expressly approved by the party responsible for compliance could void
the user’s authority to operate the equipment.
To comply with the FCC RF exposure compliance requirements, this device and its antenna must not be
co-located or operating to conjunction with any other antenna or transmitter, except if installed in
compliance with FCC Multi Transmitter procedures.
To inherit the modular approval, the antennas for this transmitter must be installed to provide a
separation distance of at least 20cm from all persons and must not be co-located or operating in
conjunction with any other antenna or transmitter.
Note:
The buyer of the module who will incorporate this module into his host must submit the final product to
the manufacturer of the module and the MANUFACTURER OF THE MODULE WILL VERIFY that the
product is incorporated in host equipment in a way that is represented by the testing as shown in the test
report.
Tarang P User Manual
Page 4 of 17
2. Tarang-P series
Tarang-P series modules are designed with low to medium transmit power and for high reliability wireless
networks. The modules require minimal power and provide reliable delivery of data between devices. The
interfaces provided with the module help to directly fit into many industrial applications. The modules
operate within the ISM 2.4-2.4835 GHz frequency band with IEEE 802.15.4 baseband.
2.1 Features
•
ZigBee® Pro Complaint platform.
•
Direct Sequence Spread Spectrum.
•
RF Data rate: 250 kbps.
•
Acknowledgement mode communication with retries.
Tarang P User Manual
Page 5 of 17
3. Tarang P20
3.1 Specifications
Power
Supply Voltage (VCC)
3.3 to 3.6V
Transmit Current
165 mA (typical)
Idle/Receive Current
35mA
Power-down Current
<60µA
General
Operating Frequency
ISM 2.4 GHz
Transmit Power Output
19dbm (typical)
RF Data Rate
250 Kbps
Receiver Sensitivity
-105 dBm
Serial Interface Data Rate
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 baud
Operating Temperature
-40 to 85 degree C
Antenna Options
Wire Antenna
Network
Supported Network Topologies
Mesh/Star
Number of Channels
15 Direct Sequence Channels
Addressing Options
PAN ID, Channel and Address
Tarang P User Manual
Page 6 of 17
3.2 Mechanical Drawings
Tarang P User Manual
Page 7 of 17
4. Interface
The Tarang modules interface to a host device through a logic-level asynchronous serial port.
Through its serial port, the module can communicate with any logic and voltage compatible UART or
through a level translator to any serial device (For example: RS-232 or USB interface board). Tarang can
be interface with a micro controller or a PC using serial port with the help of appropriate level conversion.
Tarang supports serial data with,
•
Flow Control
: None
•
Parity
: None
•
Baud Rates
: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
•
Data Bits
: 8
Tarang P User Manual
Page 8 of 17
To establish a successful serial communication with the module, serial parameters need to be configured
properly in the module and host side. Both the module and PC settings can be viewed and set using AT
command set through popular terminal applications like ‘HyperTerminal’.
4.1 Interfacing with microcontroller
Tarang P User Manual
Page 9 of 17
5. Table of AT Commands
Tarang module expects numerical values in Hexadecimal. All AT commands used by
Tarang modules are sorted by category. Tarang modules can be configured back to factory
settings with a single command ‘ATGRD’.
5.1 Table of General AT Commands
AT Command
GRD
GWR
GER
GEX
Description
Parameter and Range
Default Value
0x00 - 0x0E
Restore Defaults: Module will
be configured to factory
settings
Write: Stores the set
parameters to flash
Erase: Software flash erase of
the module
Exit: Exit from command
mode
NCH
Channel: Read the channel
number used for
communication
0 - 1200
1 - 2400
2 - 4800
SBD
Interface data rate: Read /
Set the serial interface data
rate for the module
0x00 - 0x07
3 - 9600
0x03
4 - 19200
5 - 38400
6 - 57600
7 - 115200
Tarang P User Manual
Page 10 of 17
6. Updating Firmware
6.1 Software erase of code
+++
OK
ATGER
OK
ATGEX
EXIT
6.2 To Hardware Erase of the module
1. Connect the pad below the pin 11 (on the shield side) of the module to 3.3V (preferably on the
LM117 output).
2. Plug the module into the interface board and power it ON for few seconds. The RX LED on the
interface board should light ON continuously.
3. Power OFF the module.
4. Remove the wire connection between the pad and the 3.3v source. The module is now ready to
be loaded with new code.
Tarang P User Manual
Page 11 of 17
6.3 Steps
s to load the
e firmware
1. Open
the MTM
M Codeloader application which
has been provided to
o you.
2. Choose the pro
oper com porrt, where the module is con
nnected.
Tarang P User Manuall
Page 12 of 17
3. Choose the pro
oper com porrt, where the module is con
nnected.
ng-P Series” in
n the Module Type.
4. Choose “Taran
5. Lo
ocate the firm
mware to be lo
oaded using browse
option
Tarang P User Manuall
Page 13 of 17
6. Prress F4 or clicck on the Run
n button, you should see a console wind
dow as shown
n below.
Tarang P User Manuall
Page 14 of 17
ding the windo
ows gets closed automatically, and give
e a reset to th
he module to start working
g.
After load
Tarang P User Manuall
Page 15 of 17
7. Placement Guidelines
For obtaining the best possible range, the following guidelines must be adhered to while using Tarang
modules.
1. It is important to ensure that the antennas (chip or wire) on the modules “see” open space
around them. Hence the modules must be mounted in such a way that there are no blocking obstacles
immediately next to the antennas. The modules must never be put inside a metallic enclosure unless an
external antenna is being connected to the module. The modules must not be placed too close to a wall,
table or metallic surfaces.
2. The modules must be placed as high as possible from the ground.
3. Polarization of the antennas must be the same at both sides of the link. For modules with chip
antennas, the mounting should be such that the axes of the modules are parallel to each other. For wire
antenna modules, the modules must be mounted such that the wires are parallel.
4. As far as possible, obstacles should be avoided in the communication path between the
modules. Metallic objects and concrete walls produce a lot of attenuation and these must be avoided to
the extent possible.
Tarang P User Manual
Page 16 of 17
8. Contact Details
Melange Systems Private Limited,
#4/1, 7th Cross,
Kumara Park West,
Bangalore- 560 020,
India.
Ph: +91-80-23462175/23561023
Email: info@melangesystems.com
Web: http://www.melangesystems.com
Copyright Melange Systems Pvt. Ltd. 2011.
Tarang P User Manual
Page 17 of 17

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Page Count                      : 17
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:e7a35399-562b-49d6-a958-5987b946e0fd
Producer                        : Acrobat Distiller 6.0 (Windows)
Create Date                     : 2012:06:12 15:26:57+05:30
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2012:06:12 15:26:57+05:30
Document ID                     : uuid:3e989389-08e9-4097-bfac-6c1cb182ba42
Format                          : application/pdf
Title                           : Microsoft Word - Tarang-P20 Prodict Manual
Creator                         : KVR
Author                          : KVR
EXIF Metadata provided by EXIF.tools
FCC ID Filing: N3Y-TARANG-P20

Navigation menu