DRAFT
(are I'I'IERTIK mnxn'nou (a?
mu En no tuc-
wmm o. u. m
nm or nan-14mm
mm mm m-
6&/ Operating Instructions - Handset Remote Controls G6R-H
FCC ID: RTDVGGRT
(6 fl; F6
CAUTION! Please read and iotlow these instructions for inswllation and operation entirely before use.
The product must be installed and operated according to all applicable regulations!
Standard Display Timer & Thermostat
Remote Handset Remote Handset Rtmote Handset:
GGR-HSSi GSR-H3D1 G6R-H3T1
GGR-Hdsi GSR»H4D1 G6R—H4T1
we...“ Mac-5mm ihltoiusvvmt
“mu-sis. Winn-1 we“ mom...”
(CE only.) (CE my) (CE 001i
illustration 1 "lmlmlifl" 2 illustration 3
TECHNICAL DATA
Radio Frequency:
.433.92 MHz for Europe. 315MHz lor US (FCC ID: RTD-GeR) and Canada (to: 4943A-G6R)
This device complies with pen is at the FCC Rules, Operation is subject to lite lollowing two conditions: (1)This device may not cause hamiul Inlerference, and
(2) this devroe must accept any inlerierenoe received Including Inlederence thatmey cause undesired operation. Changes or modifications nolexpressiy approved
by the party responsible for compliance onuid void the user's authority to operate the equipment.
Batteries:
Max, ambient temperature
GENERAL NOTES i
Battery
~ Aher the (9 Volt) battery has been installed, the remote handset
is ready for operar'mn.
Remove the battery, it the remote handset will not be used for
more than one year.
changing the code
- The control Is radio frequency operated, A code (chosen from
among 4000 available codes) is preset tor all Mertik Maxltrol
valves, but can be changed it required (15 additional codes
available). Change DIP switch position (Illustration 4).
Then press the receiver's reset button until you hear a second
(longer) signal. When pressing the V button on the remote
handset in the following 20 sec., the receiver learns the new
code. When the receiver is placed in the heater. the surrounding
metal diminishes reception considerably. The position of the
antenna on the receiver also influences
reception (see "Instructions for
Installation and Operation e-FLAME
Remote Electronic Ignition System").
shut-off Procedure
' To save battery power, press V to turn
main gas to pilot gas. Press OFF button
to shut off the device including pilot
flame. The heater can be shut on with
the ON/OFF switch located atthe valve. ,
thus disabling the remote handset. mifigflmfiw"
STANDARD REMOTE HANDSET (Illustration 1 and 5)
Start Ignition
- Press buttons K and A simultaneously. A short acoustic signal
confirms the start sequence has begun. Furihershort acoustic signals
(0.2 sec, 1 Hz) indicate the ignition process until it is completed and
main gas llows. If pilot is alreadylit. motor will tum to ON position (max.
llame height) while buttons are pressed down.
- Press (A) to turn on the main burner and to increase the flame
height. Press (V) to decrease the flame height and to shut olfthe
main burner.
ii:
x 9V block (quality alkaline recommended)
emote handset with batteries 60°C (140°F)
- Short tapping of either button allows incremental change in flame
height.
Switch off
Press OFF button to switch off the main gas and the pilot gas.
Illuslmlhn 5 illustration 5
DISPLAY REMOTE NAN DSET (Illustration 2 and 6) ‘1
Setting the time
After connecting the battery or by simultaneously pressing A and
V the display will start to flash.
Press A to set the hour and V to set the minute.
Wait or press OFF to return to the manual mode.
Set the display (‘C/Z4h’F/12h)
Press OFF and V until display changes irom “F (and 12 hour
clock) to “C (and 24 hour clock) or vice versa,
Start Ignition
- Press buttons 4K and A simultaneously. Ashort acoustic signal
confirms the start sequence has begun. Further short acoustic
signals (0.2 sec, 1 Hz) indicate the ignition process until it is
completed and main gas flows. Ii pilot is already lit, motor will
turn to ON position (max. flame height) while buttons are
pressed down.
- Press (A) to turn on the main burner and to increase the flame
height. Press (V) to decrease the flame height and to shut off
the main burner.
~ Short tapping of either button allows incremental change in
flame height.
switch off
Press OFF button to switch off the main gas and the pilot gas.
GvsRM-io-Eumzntn
iTIMER & THERMOSTAT REMOTE HANDSET (Illustration 3 and 7)‘
Set the time
. After connecting the battery or by simultaneously pressing A
and V the display will start to flash. You are in the set mode.
. From SET mode press A to set the hour and V to set the
minute.
- Wait or press OFF to return to the manual mode.
Set the display (‘C/24h (—)°FI1Zh)
. Press OFF and V until display changes from ”F (and 12 hour
clock) to ”C (and 24 hour clock) or vice versa.
changing the mode otoperation
Pressing the SET button quickly changes the mode oi operation
in the iollowing order: Ejafiq ) _> _>@
Manual flame height adjustment (@ appears on display):
The MAN mode can be reached by pressing the A or theV
button. Press A to turn on the lire (main burner) or to increase
flame height. Press V to decrease flame or to go down to pilot.
A symbol indicating transmission appears on display. The
receiver acknowledges the transmission with an acoustic
signal.
The day time temperature mode ( in? appears on display):
The sensor in the transmitter measures the room temperature.
The controller compares the room temperature with set
temperature and sends a signal to the receiver to turn the gas
valve motor up or down, to adjust the flame height accordingly.
The nighttime setback temperature ppears on display):
Like above there is a setting for nig e temperature control.
in this setting the room temperature is compared to the night
setback temperature, There is a bigger temperature differential
during this cycle (saves energy).
Timer: The timer mode (- appears on display) operates
much like the temperature mode above. There is a temperature
control feature like in the setting and the same in
setting. The timer setting allows you to set specific times tor cm
and oft. (There are 2 burner on and 2 burner off cycles every 24
hrs.) It the setting of is , the motor will turn the valve
to the standby pilot pos on and await the next burner .,on" cycle.
The display shows the setting tempemture every 30 seconds.
Setting the temperature
- Select the desired mode of operation (- or @) by
pressing the SET button briefly.
Hold the SET button until the display flashes.
. Set the temperature with A or V (40°F is the minimum
temperature).
. Wait or press OFF to go to temperature control mode.
It the temperature control in moon times should be ofl (lower
battery consumption), decrease the night temperature until
E] appears on display.
Set the timer
. Switch to timer mode by pressing the set button briefly.
. Press the SET button til flashes.
Set the hours with A and minutes with 7.
Press SET briefly for the next burner cycle time.
if all 4 times are set. pressing the OFF button or waiting will
complete the programming.
startlgnltlon
Press simultaneously A and OFF (Spark) button.
Switch of!
Press OFF button to switch oft the main gas and the pilot gas.
Barr BEBEfi
git)
MAN rm; TIMER
illustration 7
G30-ZWHG WALL BRACKET FOR REMOTE HANDSET (OPTIONAL)
hail-m contains: Air-main 1
a u
1 Wall Bracket A = ° C:
s n
2 5mm 5 — _ o a.
isms—a c n
zw-ii mm D a
| Sync-r a
mum mm isnemh'ri
. W-ll mm. s
”Imm- 2 Ammm- J
c s
9 m e
l r
e n
._ c:-
Mertik Maxlirol GmbH &Co. KG
Warnstedter Str. 3, 06502 Thais. Germany
Tel.: 449459474004), Fax: eds-3947400200
www.mertlkmaxitrol.com
2/2
Mertlk Maxltrol GmbH & Co. KG — Branch Office
lndustriestrasse t. 43303 Senden, Germany
Tet: 449459736324). Fax: “194597363299

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 2
Has XFA                         : No
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:43355935-7192-49dc-8978-34aecc150058
Producer                        : Adobe Acrobat 6.0.1 Paper Capture
Create Date                     : 2004:05:10 09:27:54+02:00
Creator Tool                    : Fiery Remote Scan 4.4
Modify Date                     : 2004:05:12 09:54:45+02:00
Metadata Date                   : 2004:05:12 09:54:45+02:00
Document ID                     : uuid:802113c7-b491-4f13-8167-8e12e57ac70a
Format                          : application/pdf
Creator                         : Fiery Remote Scan 4.4
EXIF Metadata provided by EXIF.tools
FCC ID Filing: RTD-G6RT

Navigation menu