Mesa Laboratories IR1 IR Door Transmitter User Manual IRDoor User s Man

Point Six Inc IR Door Transmitter IRDoor User s Man

Users Manual

Download: Mesa Laboratories IR1 IR Door Transmitter User Manual IRDoor User s Man
Mirror Download [FCC.gov]Mesa Laboratories IR1 IR Door Transmitter User Manual IRDoor User s Man
Document ID287633
Application ID8Q2AVV2/6vAQMrOCbbcqCQ==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize13.19kB (164835 bits)
Date Submitted2002-12-05 00:00:00
Date Available2002-12-04 00:00:00
Creation Date2002-12-05 12:12:25
Producing SoftwareAcrobat Distiller 5.0 (Windows)
Document Lastmod2002-12-05 12:12:25
Document TitleMicrosoft Word - IRDoor_User's-Man_.doc
Document CreatorPScript5.dll Version 5.2
Document Author: Katie

FCC ID: M5ZIR1
Installation and Operation Instructions for the Wireless IR Door .
Point Six, Inc.
Wireless IR Door Sensor Model Point Sensor IR Door
Installation and Operation Instructions
The Point Sensor IR Door wireless IR Door sensor transmits a digital value representing
either open or closed status, and the number of times the door has opened and closed and
has a unique serial number to a 418 MHz receiver. The Point Sensor IR Door is enclosed
in a high impact ABS enclosure for direct surface mounting in the environment to be
measured. Point Sensor IR Door is battery operated, the batteries may be replaced by the
user.
Application: Apply the sensor to a surface to with double-sided adhesive tape. Make
sure that the side labeled with FCC ID is visible and away from any metal surfaces.
Service Function: The wireless IR Door sensor has an installation mode switch. A
momentary push of this switch will start the convert/transmit cycles. When new and until
this button is pushed the Point Sensor IR Door will not transmit. The Point Sensor IR
Door will transmit a special installation status mark in the data packet immediately after
the installation/start switch is pushed. After the start a push of the installation switch will
result in the immediate transmission of data and ID and installation status mark.
Battery: Two 3.6 Volt lithium batteries power the Point Sensor IR Door wireless sensor.
Each battery will last for more than 10 years in the idle state (as shipped from the
manufacturer). The Point Sensor IR Door will transmit data for as long as 3 years at a
rate of once each 30 seconds once started. The Point Sensor IR Door is completely
covered with a water resistant conformal coating to protect the electronics from the
environment and condensation. The user cannot replace the battery. The Point Sensor IR
Door may be placed in a quiescent state (battery life greater than 10 years) by holding the
installation switch closed for more than 5 seconds.
FCC ID: M5ZIR1
MADE IN USA
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES, OPERATION IS
SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY
NOT CAUSE HARMFUL INTERFERENCE AND (2) THIS DEVICE MUST ACCEPT
ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY
CAUSE UNDESERED OPERATION
FCC ID: M5ZIR1
Wireless IR Door Sensor Data Format
The Point Six, Inc. 418 MHz wireless sensors require a compatible receiver with the
ability to receive, error check and provide RS232 and RS422/485 interface. This
document describes the data format provided by the HA9-wow 418 MHz. Receiver.
The transmit packet from a receiver is approximately 15 milliseconds in duration and
consists of 13 bytes of data:
1-byte ID/Mode field
8-byte serial number
2-byte pressure level as a 12-bit number
2-byte CRC-16 error check
The HA9-wow receiver processes this packet. The receiver performs a CRC-16 error
check on the packet. If the data is not accurate it is discarded. When a packet is received
that is error free it is converted to a 29-character packet and transmitted out the serial port
at 19,200 Baud. The data is transmitted serially in ASCII Hex format and terminated with
a CR character. This format requires two bytes for each byte of data; 14 data bytes x
2=28 plus the CR is 29 characters. See the HA8-wow specification for details.
The resulting binary data format of the packet is:
1-byte ID field
this field will contain a byte whose LSBit indicates the service
state of the transmitter, 0=normal, 1=service mode.
8-byte serial#
this field contains the serial number of the 1-Wire sensor.
2-byte data
this field contains the pressure data as a 12-bit number stored MSB
first. A value of 0FFF is a full scale reading and represents 30
PSIA. A zero input pressure will result in a reading of 0000.
2-byte CRC-16
this is the originally received data packet CRC as described above.
1-byte checksum
the checksum is a mod 256 sum of all the ASCII character values
in the response but does not include the CR
FCC ID: M5ZIR1
Example: “Point Sensor IR Door” Wireless IR Door Transmitter
91F1D61300050000070000BD2DE1
11F1D61300050000070000BD2DE1
string from an HA8
string from an HA9
The device type field: IR Door has device type 91/11 hex. A 90/10 hex when in service
mode.
91F1D61300050000070000BD2DE1
11F1D61300050000070000BD2DE1
string from an HA8
string from an HA9
The MS-30 bits of these 4-bytes are the serial number of the IR Door. The LS-2 bits are
the status flags for the open and closed. The LS bit (bit-0) is the Open switch flag and the
next most significant bit (bit-1) is the Closed switch flag.
91F1D61300050000070000BD2DE1
11F1D61300050000070000BD2DE1
string from an HA8
string from an HA9
This 24-bit field is the Open counter stored LS-byte first the value shown is a count of 5
open cycles.
11F1D61300050000070000BD2DE1
11F1D61300050000070000BD2DE1
string from an HA8
string from an HA9
THIS 24-BIT FIELD IS THE CLOSED COUNTER STORED LS-BYTE FIRST,
THE VALUE SHOWN IS A ACCOUNT OF 7 CLOSED CYCLES.
91F1D61300050000070000BD2DE1
11F1D61300050000070000BD2DE1
string from an HA8
string from an HA9
This field is the CRC-16 error check as was originally received and checked. This CRC
is over the first 11 bytes of the packet starting with the device type and ending with
inclusion of the temperature data.
FCC ID: M5ZIR1
FCC Radio Frequency Interference Statement
Wireless IR Door Sensor
FCC ID: M5ZIR1
NOTE: This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to Part 15, Subpart B, of the FCC Rules. This
equipment generates, uses, and can radiate radio frequency energy. If not
installed and used in accordance with the instructions, it may cause interference
to radio communications.
The limits are designed to provide reasonable protection against such
interference in a residential situation. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does
cause interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try and correct the
interference by one or more of the following measures:
ƒ
ƒ
ƒ
ƒ
Reorient or relocate the receiving antenna of the affected radio or television
Increase the separation between the equipment and the affected receiver.
Connect the equipment and the affected receiver to power outlets on separate
circuits.
Consult the dealer or an experienced radio/TV technician for help.
MODIFICATIONS
Changes or modifications not expressly approved by Point Six Inc. could void
the user's authority to operate the equipment.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Create Date                     : 2002:12:05 12:12:25-05:00
Modify Date                     : 2002:12:05 12:12:25-05:00
Page Count                      : 4
Creation Date                   : 2002:12:05 17:12:25Z
Mod Date                        : 2002:12:05 17:12:25Z
Producer                        : Acrobat Distiller 5.0 (Windows)
Author                          : Katie
Metadata Date                   : 2002:12:05 17:12:25Z
Creator                         : Katie
Title                           : Microsoft Word - IRDoor_User's-Man_.doc
EXIF Metadata provided by EXIF.tools
FCC ID Filing: M5ZIR1