Mesa Laboratories VPX900 VPx Sensor 900 MHz with LCD User Manual
Mesa Laboratories, Inc. VPx Sensor 900 MHz with LCD
User Manual
VPxSensorUserManual
DocumentNo.DV1562
September29,2016
Rev.A2
VPxSensorUserManual 2
Mesa Labs, Inc.
12100 W. 6th Avenue
Lakewood, CO 80228 USA
Tel: 303-565-2724
monitoring.mesalabs.c
om
techsupport@mesalabs.com
Contents
1.0Figures...............................................................................................................................................3
2.0Introduction......................................................................................................................................4
2.1FCCNOTICE...................................................................................................................................5
2.2IndustryCanada............................................................................................................................6
3.0Features............................................................................................................................................7
3.1Buttons..........................................................................................................................................7
3.2AudioVisualAlarm........................................................................................................................7
3.3InputTypes....................................................................................................................................8
4.0Menus...............................................................................................................................................9
4.1Home.............................................................................................................................................9
4.2MinMax........................................................................................................................................9
4.3ClearMinMax.............................................................................................................................10
4.4DiagnosticsMenu........................................................................................................................10
5.0NewBattery....................................................................................................................................12
5.1BatteryReplacement..................................................................................................................12
6.0Specs...............................................................................................................................................14
6.1RTD..............................................................................................................................................14
6.2TemperatureandHumidity........................................................................................................14
6.3Power..........................................................................................................................................14
7.0LCDIconLegend..............................................................................................................................15
8.0VPxSensorwithoutLCD..................................................................................................................17
8.1Alarm...........................................................................................................................................17
8.2BatteryReplacement..................................................................................................................17
8.2.1ResettingBatteryUsage......................................................................................................18
9.0ProbeList........................................................................................................................................18
VPxSensorUserManual 3
Mesa Labs, Inc.
12100 W. 6th Avenue
Lakewood, CO 80228 USA
Tel: 303-565-2724
monitoring.mesalabs.c
om
techsupport@mesalabs.com
1.0 Figures
2‐1VPxSensorwithLCD...............................................................................................................................7
2‐2VPxSensorwithLCDButtons..................................................................................................................7
Table2‐1InputTypes....................................................................................................................................8
3‐1HomeScreen...........................................................................................................................................9
Table3‐1AccessMinMaxMenuProcedure................................................................................................9
3‐2MinMaxScreen....................................................................................................................................10
Table3‐2ClearMinMaxProcedure...........................................................................................................10
Table3‐3AccessDiagnosticsScreenProcedure.........................................................................................10
3‐3900MHzDiagnosticsScreen.................................................................................................................11
3‐4Wi‐FiDiagnosticsScreen.......................................................................................................................11
4‐1VPxSensorTopandBackView.............................................................................................................12
4‐2VPxSensorInternalView(BackCoverRemoved)................................................................................13
Table4‐1ResetBatteryLevelDisplayProcedure(LCD)..............................................................................13
Table6‐1LCDIconLegend..........................................................................................................................16
7‐1VPxSensorTopandBackView.............................................................................................................17
Table8‐1InputandAccessoryTypePartNumbers....................................................................................18
VPxSensorUserManual 4
Mesa Labs, Inc.
12100 W. 6th Avenue
Lakewood, CO 80228 USA
Tel: 303-565-2724
monitoring.mesalabs.c
om
techsupport@mesalabs.com
2.0 Introduction
TheVPxsensorintegrateswithMesa’sViewPoint1.1orabovesoftwaresolution.TheVPx900MHz
sensoroperatesina902to928MHzrange
ThisdevicecomplieswithPart15oftheFCCRules.Sensoroperationissubjecttothefollowingtwo
conditions:(1)thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustacceptany
interferencereceived,includinginterferencethatmaycauseundesiredoperation.
Ex.
Warning:Thisunitisnotexplosionproofandisnotratedforintrinsicallysafeinstallations.
VPxSensorUserManual 5
Mesa Labs, Inc.
12100 W. 6th Avenue
Lakewood, CO 80228 USA
Tel: 303-565-2724
monitoring.mesalabs.c
om
techsupport@mesalabs.com
2.1 FCCNOTICE
WARNING
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaclassBdigitaldevice,pursuant
topart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmful
interferenceinaresidentialinstallation.Thisequipmentgenerates,usesandcanradiateradiofrequency
energyandifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterference
toradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticular
installation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcan
bedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotrytocorrectthe
interferencebyoneormoreofthefollowingmeasures:
*Reorientorrelocatethereceivingantenna.
*Increasetheseparationbetweentheequipmentandreceiver.
*Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected.
*Consultthedealeroranexperiencedradio/TVtechnicianforhelp.
InordertomaintaincompliancewithFCCregulations,shieldedcablesmustbeusedwiththisequipment.
Operationwithnon‐approvedequipmentorunshieldedcablesislikelytoresultininterferencetoradio
andTVreception.Theuseriscautionedthatchangesandmodificationsmadetotheequipmentwithout
theapprovalofmanufacturercouldvoidtheuser'sauthoritytooperatethisequipment.
RFExposureNotice:TosatisfyRFexposurerequirements,thisdeviceanditsantennasmustoperatewith
aseparationdistanceofatleast20cmfromallpersonsandmustnotbeco‐locatedoroperatingin
conjunctionwithanyotherantennaortransmitter.
VPxSensorUserManual 6
Mesa Labs, Inc.
12100 W. 6th Avenue
Lakewood, CO 80228 USA
Tel: 303-565-2724
monitoring.mesalabs.c
om
techsupport@mesalabs.com
2.2 IndustryCanada
ThisdevicecomplieswithIndustryCanadalicence‐exemptRSSstandard(s).Operationissubjecttothe
followingtwoconditions:(1)thisdevicemaynotcauseinterference,and(2)thisdevicemustacceptany
interference,includinginterferencethatmaycauseundesiredoperationofthedevice.
LeprésentappareilestconformeauxCNRd'IndustrieCanadaapplicablesauxappareilsradioexemptsde
licence.L'exploitationestautoriséeauxdeuxconditionssuivantes:(1)l'appareilnedoitpasproduirede
brouillage,et(2)l'utilisateurdel'appareildoitacceptertoutbrouillageradioélectriquesubi,mêmesile
brouillageestsusceptibled'encompromettrelefonctionnement.
VPxSensorUserManual 7
Mesa Labs, Inc.
12100 W. 6th Avenue
Lakewood, CO 80228 USA
Tel: 303-565-2724
monitoring.mesalabs.c
om
techsupport@mesalabs.com
3.0 Features
3.1 Buttons
3‐1VPxSensorwithLCD
CycleUsedforcyclingthroughscreensormenuoptions
SelectSelectmenuoption
Previous/
Next
ReturntopreviousscreenorNextoption
MuteMutelocalAudioVisualAlarms
3‐2VPxSensorwithLCDButtons
3.2 AudioVisualAlarm
VPxSensorhaslocalAudibleVisualalarmstonotifyindividualsofsensoralarmstatesevenwithno
accesstotheViewpointsoftware.
VPxSensorUserManual 8
Mesa Labs, Inc.
12100 W. 6th Avenue
Lakewood, CO 80228 USA
Tel: 303-565-2724
monitoring.mesalabs.c
om
techsupport@mesalabs.com
LEDforVisualAlarm
TomutelocalAudibleand/orvisualalarms,pressthebuttontosilencethelocalalarmONLY.*To
performcorrectiveactionforalarmstates,dosointheViewPointsoftware.
*Note:Thisisonlypossiblewhenthesensorisinanalarmstate.Itcannotbeusedtomutefuture
alarms.
Mutingthesensorwiththebuttononthedevicewillonlymutethatalarm.If,aftermutingthe
localalarm,thesensorcomesbackintoandthengoesbackoutofrangeagain,thenthelocalalarmwill
betriggeredagainandwillneedtobemutedagainifdesired.
3.3 InputTypes
ParameterApplication
Temperature‐200°Cto+250°C(TypeKthermocouple,upto+538°C)
Humidity0%to100%(Temp5°Cto+40°C)
CO
2
0%to20%
O
2
0%to25%(use4‐20mAsensorandthird‐partysensor)
DoorStatusOpen/ClosedDoor
HorizontalMotionPlateletIncubator
DryContactNormalv.AlarmState(NormallyClosedorOpen)
Power 100to240V(DetectPowerOutages)
DCVoltage0to5V,0to10V,0to20V,0to30V
4‐20mAVarioussensorswithpowered4‐20mAinterface
DifferentialPressure‐1.0to+1.0inchesH20/‐.25to+.25/‐.5to+.5
ParticleCountUtilizes4‐20mASensorOutput
LeakDetectionDetectwaterincriticalareas
Table3‐1InputTypes
VPxSensorUserManual 9
Mesa Labs, Inc.
12100 W. 6th Avenue
Lakewood, CO 80228 USA
Tel: 303-565-2724
monitoring.mesalabs.c
om
techsupport@mesalabs.com
4.0 Menus
4.1 Home
4‐1HomeScreen
4.2 MinMax
TogettotheMin‐Maxscreen,startattheHomescreen,
PressResult
Step1x1MinMaxScreen
Table4‐1AccessMinMaxMenuProcedure
VPxSensorUserManual 10
Mesa Labs, Inc.
12100 W. 6th Avenue
Lakewood, CO 80228 USA
Tel: 303-565-2724
monitoring.mesalabs.c
om
techsupport@mesalabs.com
4‐2MinMaxScreen
4.3 ClearMinMax
PressResult
Step1x2OptionScreen
Step2x1SelectClearMinMax
Step3x1ConfirmClearMinMax
Table4‐2ClearMinMaxProcedure
4.4 DiagnosticsMenu
TheVPxsensorhasonboarddiagnosticcapabilitiesthatcanassistinavarietyofsetupor
troubleshootingscenarios.
Toaccessthe“Diagnostics”screen,startattheHomescreen:
PressResult
Step1x2OptionScreen
Step2x1Moveupto“Diagnostics”
Step3x1DiagnosticsScreen
Table4‐3AccessDiagnosticsScreenProcedure
VPxSensorUserManual 11
Mesa Labs, Inc.
12100 W. 6th Avenue
Lakewood, CO 80228 USA
Tel: 303-565-2724
monitoring.mesalabs.c
om
techsupport@mesalabs.com
4‐3900MHzDiagnosticsScreen
4‐4Wi‐FiDiagnosticsScreen
VPxSensorUserManual 12
Mesa Labs, Inc.
12100 W. 6th Avenue
Lakewood, CO 80228 USA
Tel: 303-565-2724
monitoring.mesalabs.c
om
techsupport@mesalabs.com
5.0 NewBattery
Note:Useonly3.6VLithium‐IonBatteries(P/N166112).TheVPxsensorwillnotpoweronwitha
normal1.5VAAbattery.
5.1 BatteryReplacement
Toreplacethe(2)3.6VlithiumbatteriesintheVPxsensor,pressdownonthetworecessedareasonthe
rearplateofthesensorandpullbackthebackcovertoopentheunit.
5‐1VPxSensorTopandBackView
VPxSensorUserManual 13
Mesa Labs, Inc.
12100 W. 6th Avenue
Lakewood, CO 80228 USA
Tel: 303-565-2724
monitoring.mesalabs.c
om
techsupport@mesalabs.com
5‐2VPxSensorInternalView(BackCoverRemoved)
Afterreplacingthebatteries,itisnecessarytoresetthebatterylevelindicator.Toresetthebatterylevel
indicator,startfromtheHomescreen:
PressResult
Step1x2OptionScreen
Step2x2Moveupto“NewBattery”
Step3x1NewBatteryConfirmation
Step4x1“Confirm”NewBattery
Table5‐1ResetBatteryLevelDisplayProcedure(LCD)
VPxSensorUserManual 14
Mesa Labs, Inc.
12100 W. 6th Avenue
Lakewood, CO 80228 USA
Tel: 303-565-2724
monitoring.mesalabs.c
om
techsupport@mesalabs.com
6.0 Specs
Allspecsbelowareestimatedrangesfortheparticularinputs.Pleaserefertotheprobespecific
documentationfortheexactrangesandtolerances.
6.1 RTD
TheVPxsensorutilizes(2)1,000OhmRTDstocover‐200°Cto+140°C
4‐WireRTD–(P/NCM‐000188)
Range:‐90°Cto+140°C
Tolerance:±0.5°C@‐25°Cto+45°C(±1.0°C@‐90°Cto‐26°Cand+46°Cto+140°C)
4‐WireCryoRTD–(P/NCM‐000189)
Range:‐200°Cto+70°C
Tolerance:±1.0°Coverfulloperatingrange
6.2 TemperatureandHumidity
VPxmonitorstemperatureandhumiditywithanexternalprobe.
TemperatureandHumidityProbe–(P/N72112)
Range:+5°Cto40°Cand10%RHto90%RH
Accuracy:±0.5°Cand±3%RH
6.3 Power
VPxsensormakesuseofa5V1AAC/DCWallMountAdapter(TWA22–PowerSupply)
VPxSensorUserManual 15
Mesa Labs, Inc.
12100 W. 6th Avenue
Lakewood, CO 80228 USA
Tel: 303-565-2724
monitoring.mesalabs.c
om
techsupport@mesalabs.com
7.0 LCDIconLegend
IconDescription
Alarm,above/belowalarmlimits
Alarm,limits(Min‐Maxscreen)
BatteryFull
Battery2/3
Battery1/3
BatteryLow
A/CPowerconnected
Home
Settings
Linkbroken
Linkconnected
MinMax
FastTransmit
Memory1/3full
Memory2/3full
Memoryfull
SoundOn
VPxSensorUserManual 16
Mesa Labs, Inc.
12100 W. 6th Avenue
Lakewood, CO 80228 USA
Tel: 303-565-2724
monitoring.mesalabs.c
om
techsupport@mesalabs.com
SoundMuted
IconforMin/Maxscreen
Motion(notmoving)
Motion(Moving)
Contact
NoContact
DoorOpen
DoorClosed
SignalQuality(nosignal)
SignalQuality–Poor
SignalQuality–Fair
SignalQuality–Good
SignalQuality–Best
Table7‐1LCDIconLegend
VPxSensorUserManual 17
Mesa Labs, Inc.
12100 W. 6th Avenue
Lakewood, CO 80228 USA
Tel: 303-565-2724
monitoring.mesalabs.c
om
techsupport@mesalabs.com
8.0 VPxSensorwithoutLCD
TheVPxsensorswithoutLCDshaveonlyonebuttononthefront.
MuteMutelocalAudioVisualAlarms
8.1 Alarm
TomutelocalAudibleand/orvisualalarms,pressthebuttontosilencethelocalalarmONLY.*To
performcorrectiveactionforalarmstates,dosointheViewPointsoftware.
*Note:Thisisonlypossiblewhenthesensorisinanalarmstate.Itcannotbeusedtomutefuture
alarms.
Mutingthesensorwiththebuttononthedevicewillonlymutethatalarm.If,aftermutingthe
localalarm,thesensorcomesbackintoandthengoesbackoutofrangeagain,thenthelocalalarmwill
betriggeredagainandwillneedtobemutedagainifdesired.ProbesandAccessories
8.2 BatteryReplacement
Togettothebatteries,pushthetabsonthetopofthesensorandpullbackthebackcover.
8‐1VPxSensorTopandBackView
VPxSensorUserManual 18
Mesa Labs, Inc.
12100 W. 6th Avenue
Lakewood, CO 80228 USA
Tel: 303-565-2724
monitoring.mesalabs.c
om
techsupport@mesalabs.com
8‐2VPxSensorInternalView(BackCoverRemoved)
8.2.1 ResettingBatteryUsage
Toresetthebatteryusagecounter,firstremovetheoldbatteries.Waitaboutoneminutewiththe
batteriesremoved.Holddownthebuttonandinsertthenewbatteries.
Note:Keeppressingthebuttonwhileinsertingthenewbatteries.
9.0 ProbeList
Input/AccessoryTypePartNumber
StandardRTDCM‐000188
CryoRTDCM‐000189
Temp/Humidity(Snap)72112(requiresCM‐000164)
AnalogCableCM‐000284
DoorSwitch,Motion,AlarmContactCM‐000183
3.6VLiBatteries166113
ACAdapterTWA26
Table9‐1InputandAccessoryTypePartNumbers