Mettler Toledo EASYSCANUSB RFID Reader/Writer User Manual EasyScan USB

Mettler-Toledo GmbH RFID Reader/Writer EasyScan USB

Installation Instruction

Download: Mettler Toledo EASYSCANUSB RFID Reader/Writer User Manual EasyScan USB
Mirror Download [FCC.gov]Mettler Toledo EASYSCANUSB RFID Reader/Writer User Manual EasyScan USB
Document ID4184372
Application IDDcHFqZhuUwT1DY3ZORh/Hw==
Document DescriptionInstallation Instruction
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize68.15kB (851831 bits)
Date Submitted2019-02-28 00:00:00
Date Available2019-02-28 00:00:00
Creation Date2018-12-13 15:46:05
Producing SoftwareST4 PDF Engine (Build 7.0.2.0)
Document Lastmod2018-12-13 15:46:05
Document TitleEasyScan USB
Document CreatorSCHEMA ST4
Document Author: © Mettler-Toledo GmbH

Installation Instructions
EasyScan USB
for reading and writing RFID tags
Additional languages available online.
u www.mt.com/EasyScan-USB-INI
1 Installation
Optional: The EasyScan USB can also be used as a laboratory equipment with the LabX interface via
a USB connection to a computer.
For a detailed description of how to use the EasyScan USB (connecting a USB device, using an RFID
reader), see the balance Reference Manual (RM).
u www.mt.com/XPR-analytical-RM
2 Technical Data
2.1 General technical data
EasyScan USB
Electrical data:
5 V DC, 0.3 A, 1.5 W max.
Weight (without packaging):
295 g
Protection and standards
Overvoltage category:
II
Degree of pollution:
Range of application:
For use in closed interior rooms only
Environmental conditions
Height above mean sea level:
Up to 5000 m
Ambient temperature:
+5 – +40 °C
Relative air humidity:
20 – 80%, non-condensing
Storage conditions (in packaging)
Ambient temperature:
-25 – +70 °C
Relative air humidity:
10 – 90%, non-condensing
Materials
Housing:
Lacquered aluminum; anodized glass; plastic
2.2 Dimensions
32
85
Dimensions in mm.
116
3 Cleaning
The EasyScan USB is made from high quality materials and can be cleaned with a commercially available, mild
cleaning agent.
The cleaning interval depends on your standard operating procedure (SOP).
WARNING
Electric shock
1 Disconnect the EasyScan USB from the balance prior to cleaning.
2 Prevent liquid from entering the instrument.
3 Do not open the EasyScan USB.
4 Compliance Information
United States of America
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to
radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own expense.
Canada
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic
Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:
1. This device may not cause interference.
2. This device must accept any interference, including interference that may cause undesired operation of the device.
5 Disposal
In conformance with the European Directive 2012/19/EU on Waste Electrical and Electronic
Equipment (WEEE) this device may not be disposed of in domestic waste. This also applies to
countries outside the EU, per their specific requirements.
Please dispose of this product in accordance with local regulations at the collecting point specified
for electrical and electronic equipment. If you have any questions, please contact the responsible
authority or the distributor from which you purchased this device. Should this device be passed on
to other parties, the content of this regulation must also be related.
6 Service
Do not open the EasyScan USB. It contains no user-serviceable parts. Contact a METTLER TOLEDO representative to
learn more about the service options available.
Mettler-Toledo GmbH
Im Langacher 44
8606 Greifensee, Switzerland
www.mt.com/contact
Subject to technical changes.
© Mettler-Toledo GmbH 12/2018
30419764B en
30419764

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
Linearized                      : No
Page Count                      : 4
Page Mode                       : UseOutlines
PDF Version                     : 1.6
Language                        : en-US
Title                           : EasyScan USB
Author                          : © Mettler-Toledo GmbH
Subject                         : for reading and writing RFID tags
Keywords                        : EasyScan, USB, for, reading, and, writing, RFID, tags,  30419764
Creator                         : SCHEMA ST4
Producer                        : ST4 PDF Engine (Build 7.0.2.0)
Create Date                     : 2018:12:13 15:46:05+01:00
Modify Date                     : 2018:12:13 15:46:05+01:00
EXIF Metadata provided by EXIF.tools
FCC ID Filing: THVEASYSCANUSB

Navigation menu