Microframe 1904 User Manual 13073

Microframe Corporation 13073

8

Download: Microframe 1904 User Manual 13073
Mirror Download [FCC.gov]Microframe 1904 User Manual 13073
Document ID13073
Application IDAuhNM9fUmwWY25AVX/7aFw==
Document Description8
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize25.12kB (313951 bits)
Date Submitted1998-11-18 00:00:00
Date Available1999-01-22 00:00:00
Creation Date2001-07-10 03:15:41
Producing SoftwareAcrobat Distiller 4.0 for Windows
Document Lastmod2001-07-10 03:15:43
Document Title13073.pdf
Document Author: jsoscia

Table of Contents
FCC Notice ......................................
Model 1904 Keypad Specifications.
Models 1940 Remote Display Specifications
Important I’m—Installation Instructions
Permanent .....
Installation
FIRST: Select location or isp ay and Keypad.
SECOND: Install The 1904 Keypad
THIRD: Install the Remote Display
VISUAL-PAGER 1904 Keypad
Display Model 1940
Explaination of Error Codes .
Troubleshooting Chart ...... 9
Index ...............................
Microframe Corporation
PO. Box 1700
Broken Arrow, OK 74013
Phone: (918) 258-4839
FCC Notice
This device has been tested andfound to comply with the limits for a ClassB digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This device generates, uses, and can radiate radio
frequency energy and, if installed and used in accordance with the instruction, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this device does cause harmful interference to radio or television
reception, the user is encouraged to try to correct the interference by one or more of the following
measures:
0 Reorient or relocate the receiving antenna.
0 Increase the separation between the Visual-Pager and receiver.
0 Connect the Visual-Pager into an outlet on a circuit different from that to which the receiver is
connected.
0 Consult the dealer or an experienced radio/ TV technician for help.
Caution: Any changes or modifications not expressly approved by the grantee of this device could
void the user's authority to operate the equipment.
Model 1904 Keypad Specifications
Model 1904 Keypad
Local Keypad Display Built-in LED readout
Remote Display Wall mount 5 1/2" LED Display
Maximum Number of Digit Four digits
30 four-digit numbers will be stored and sequenced
until deleted.
Maximum Number of Keypads ........................... Up to 32 Keypads may be connected together
using 2 wires to allow input from different
locations and a combined output to one or
more displays.
Power Input Requirements .................................. 24VAC 1.2A supplied by transformer which re-
quires 115 Volts AC @ .72 Amps
. 1.5 Amp GMA (5mm x 20mm) fast-acting fuse
. .75 lb (.4 kg) with transformer 2.25 lb (10 kg)
Maximum Number of Numbers Stored 4
Fuse Requirements.
Weight ................
RF output ............................................................ 902-928 Mhz.
fin .—. .—.
7.50"
1190m)
3&5
x32
n.
523
'5E
l . l
4.00" 13
(102 cm) (33 cm)
ARCHITECTS SPECIFICATIONS; The Visual-Paging System shall use a Keypad capable ol transmiting signal to Remote
Displays. The Keypad shall have a display to show the number being entered as well as the number being shown on the
Remote Display The Keypad shall be capable ol holding 30 four-digit numbers and rotating them every 3 seconds. Multiple
Keypads may be connected at any lime by attaching them with a cable going between keypads. Numbers may be entered
or deleted lrom any Keypad. The Keypad shall be supplied with a surface-type wall mount bracket. The Keypad shall be
powered by a 12 amp UL approved wall mount 2¢volt transformer. The Keypad shall be tused with a 1.5 amp fuse.
Mieroframe Corporation 0 P.0. Box 1700, Broken Arrow, OK 74013 0 918-258-4839
Models 1940 Remote Display
Specifications
Microframe Model 1940 Remote Display
Remote Display Wall mount 5 1/2" LED Display
Power Input Requirements ................................. 24VAC 1‘2A supplied by transformer which
requires 115 Volts AC @ .72 Amps
5.5 inch (14 cm)
. 150 feet (45 meters)
4 Digit, 345 Lbs (L6 kg)
Character Height .t
Character Viewing Distance
Weight ................................
Operation
The Remote Display is designedto operate with the Model 1904 Keypad . The Remote Display receives
signal from the Keypad.
Models 1940 Remote Display
Front View A Rear View
u... -.00- n...
9.|'
(23.1 cm)
9.5' zolslt—i I 1.5" i
(20.9 em) (33 cm)
113.2" s-DlGn'
(33.5 mi
rink mlult
(an em)
ARCHlTECT‘S SPECIFICATIONS: The Remote Display shall be a Microlrarne Model 1940(lour-d|g|t)surlace mount display.
It shall hang on a single lastener extending cm 3/8 inch lrom the wall. The numbers shall be 5 1/2 inches (14 cm) tall. The
Model 1940 LED Display shall receive signal lrom the Model 1904 Visual-Pager Keypad. The Keypad will accept up to lour
digils Only high brighlness wide-viewing angle LEDs shall be used in the construction.
Microlrame Corporation 0 PD. Box 1700, Broken Arrow, OK 74013 0 918—258-4839
INSTALLATION PROCEDURE
When installing the Visual-Pager System, the following
procedures should be followed.
IMPORTANT PRE-INSTALLATION INSTRUCTIONS
Before permanent installation, we recommend that
you test your entire system in one room on a table or
floor. This will be of great benefit in troubleshooting
if you should have any problem after installing the
system.
STEP 1: Test 1904
Connect the wall mount transformer to the Model
1904 Keypad at the 18-24 VAC connector. Turn
power "ON" and enter a number, If the number
appears on the Keypad display, the Keypad is working.
Microlrame Plastic Mounting Bracket
with Two Screw Mounting Holes
EA
SIDE VIEW
REAR VIEW
Mounting for Model 1904 Keypad
STEP 2: Test 1904 & Display
Connect the wall mount transformer to the dis—
play at the 18-24 VAC connector. Type numbers
into the keypad and they should appear on the
remote display.
Permanent
Installation
FIRST: Select location for Display
and Keypad.
In almost all Iowpower unlisenend wireless sys-
tems there is a chance that some places in a particular
building may be "dead spots". (Places were the dis-
play will not receive the signal from the keypad.)
These ”dead spots" however may only be a few
inches apart. Therefore moving a display 6 inches in
any direction could well make the difference between
a working and nonworking system. To select the
place were the system will best work for you Place the
keypad in your most ideal location. Lean it aginst
someting so the antenna is vertical like the display.
This will establish the best signal Iink.Type several
numbers in to the keypadlike 10, 20, 30. Next take
the display to its most Ideal location. If the numbers
appear on the display and rotate through every 3
seconds then everything is fine and you may proceed
with the permant installation. If however the system
is not working try moving the display or kepad to
slightly different locations and repeat the test until
you find a suitable setup for the system.
CAUTION
24 VOLTS A.C. IS PRESENT UNDER THE
SMALLSLIDE—ON COVER. TURN POWER OFF
TO PREVENT DAMAGE TO 1904 UNIT.
INSTALLATION PROCEDURE
(conti nued)
SECOND: Install The 1904 Keypad
Select a location that is handy but not in the way
The Model 1904 Keypad should be mounted on the
wall with the antenna pointing up. Locate the Keypad
so that the cord from the wall-mount transformerwill
not be accessible to children or present a safety
hazard. The installation location must bewithin 5 feet
of an AC power outlet so that the cord may reach the
Keypad.
Place the Keypad in the enclosed plastic wall
mounting bracket, if needed. Place at the desired
mounting location and mark the position. Slide the
Keypad out of its mountinghracket and attach bracket
using screws supplied. Once screws are screwed in
flush with back of bracket, slide Keypad into bracket.
The Keypad is easily removed, if necessary.
Installthe Keypad andconnectto AC powerl Test
for operation by entering a number and observing
this number in the built~in display of the Keypad.
This verifies that the keypad is working.
THIRD: Install the Remote Display
The Remore Display will have optimum visiblity
when mounted within five to 10 feet of the stage floor.
This will keep the display in the proper field of view
for the observer.
Type several numbers in to the keypadlike 10, 20,
30. Then hold the remote display in position and
watches the numbers. If the numbers appear on the
display and rotate through every 3 seconds then
everything is fine and you may proceed with the
permant installation The Remote Display may he
hung on a screw anchored in the wall.
1904 FEATURES
0 Multiple Paging
0 Multiple Inputs / Outputs
0 User Programmable Options
0 Wireless 900 Mhz
Use with:
0 Model 1940 4-diglt Display
OPERATION
Instructions for Use
The Model 1904 Keypad has its own built-in, easye
to—read display so that you can see what numbers are
being entered as well as what numbers are being
shown on the Remote Display.
Normal Mode
While in normal mode, the Keypad display will
show the same numbers as the Remote Display.
Enter Mode
When a number button is pressed, the Keypad will
go into enter mode and the "ENTER" light will flash.
While in enter mode, the number to be paged will be
shown only on the Keypad display. Continue to press
number buttons until the complete number to be
paged is shown. Then press "ENTER" to display the
paging number on the 1940 Remote Display. When
"ENTER“ is pressed, the Keypad will leave the enter
mode and the new number will be placed in sequence
with any other numbers displayed on the Remote
Display. If you make an error while entering a num—
ber, press "DELETE."
Delete Mode
To delete a paging number, press "DELETE"
when that number appears on the display. The next
available number will be displayed immediately. You
may also delete a number at any time by typing the
number and pressing "DELETE."
Multiple Paging
The Keypad will store up to 30 four—digit numbers
and display them sequentially until the operator de-
letes them. These numbers may be entered one at a
time using the instructions above.
Multiple Outputs
You may have an unllimited number of Remote
Displays connected to your system.
Multiple Keypads - Model 1904
You may cascade up to 32 Model 1904 Keypads by
wiring the keypads together. Use a common cable
connected to the “Signal Out" output from each
Keypad. Numbers entered from each Keypad will
automatically be combined and displayed in sequence
with all the numbers entered from all Keypads. Each
Keypad will display all numbers entered from itself as
well as all numbers entered from all other Keypads at
the same time they are displayed on the Remote
Display(s). A number may be deleted by pressing
"DELETE" on any Keypad when that number ap-
pears in the Keypad Display, or by typing in the
number then pressing "DELETE."
Power Connection
Connect the wall mount transformer to an AC
outlet and connect the power plugto the connector on
the top of the Keypad marked "18-24 VAC ." It is
recommended that you turn the power off using the
“ON/OFF" switch on the Keypad when not in use.
This will greatly prolong the life of the system.
Fuse
The Model 1904 Keypad contains a fuse inside the
case under the small slide-on cover. When replacing
the fuse, be sure to disconnect power from the AC
wall outlet. Replace only with the fuse size stated in
the 1904 SPECIFICATIONS; otherwise permanent
damage may occur.
Programming Options
The following user programmable options are
available in the Model 1904 VisualvPager. See Pro-
gramming Instructions on pages 15 and 16 for details.
Option 13....Change display rotation time from O
to 9 seconds. When 0 is selected, the display
will only rotate one number each time the
DELETE Button is pressed.
Option 14....Automatically delete numbers after
a delay of 1 to 9 minutes.
Option 17....Delete Keypad sound.
Option 19....Reset to Factory Defaults.
Option 21....Cancel Number Sort
Option Connections
The Model 1904 Keypad has two optional connec-
tions on the 8-pin terminal block located under the
small removable cover;
1. AUX—Auxiliary connection for use with the
extra cost Remote Delete Option.
2 NC—Remote 24 VAC Input used when a trans-
former other than the wall mounted one supplied
with the system is required, such as an attic-mounted
transformer installation.
Display Features
0 5 1/2" LED Numbers
0 Four-Digit Remote Displays
0 Simple Surface Mount
POWER
Each Remote Display must be connected to a 24
Volt AC adapter. This supplys the power to the
displaly.
MAXIMUM NUMBER OF DISPLAYS
You may have an unllimited number of Remote
Displays connecred to your system.
USER SERVICEABLE PARTS
There are no user serviceable parts inside the
Remote Display. If the Display fails to work consult
the factory for replacement or repair.
Explaination of Error Codes
There are four error conditions that will cause an Error Code [0 appear on the Model 1904 Keypad display.
It will be of great assistance in troubleshooting the system if you will note the displayed code when calling the
factory for assistance. Call 1—800635-3811 for technical support.
El-SHORTED CABLE There is a shorts on the cable between keypads probally within
to ~-
EZ-SHORTED CABLE There is a shorts on the cable between keypads p robally over 100feet
away.
E3-NO SIGNAL OUTPUT
The output transistor is blown and there are no numbers shown on
the Remote Displays. DO NOT ATTEMPT TO CORRECT
THIS PROBLEM. Return the Model 1904 Keypad to the factory.
There is a programming error. Return Model 1904 Keypad to
Factory Defaults by PRESSING 19 in the Programming Mode (see
Programming Instructions for more details).
E4-PROGRAMMING ERROR
Troubleshooting Chart
SYMPTOM POSSIBLE CAUSE CURE
Keypad display and Remote Keypad is not connected to CheckAC wallconnection orchango to
Display are not working. power. Power supply is bad or another wall outlet.
Keypad fuse blown. Replace Model 1904 Keypad fuse.
Keypad display works but Power may not be connected chock power connoctlon to display.
Remote Display do" not to display. Make sure power lite Is ON.
work.
Keypad works but d Keypad Output transistor Is blown. Return Model 1904 Keypad to iactory.
displays 53.
Model 1904 Keypad works Cable connecting other key- Syltimaticelly disconnectcabla oruaa
until the cable connecting pads is shorted. ohmmeter to dotermin where short is
other keypada I; plugged in. located.
than it displays E1 or E2.
Reset to Faotory De'aults (sea Pro-
Keypad display shows E4. Programming error. cramming Instructions).
Programming Instructions
The Model 1904 Visual-Pager offers several User Programmable Options which can easily be entered by
adhering to the following instructions,
Programming Mode
To enter the Programming Mode, hold the ”ZERO" key down when turning the Model 1904 "ON." The
Model 1904 Keypad will display the serial number. Release the "ZERO " key, you are now in the Programming
Mode. To change any of the factory selected defaults, select the Option Number listed below and press that
number. To EXIT the Programing Mode, simply press "DELETE' Should the Error Code E4 appear at any
time, you may return the system to the factory defaults (Option Number 19) and start over.
OPTION NUMBER 1: Display Software Revision Number
Once in the Programming Mode, press "ENTER" on the Keypad and the current Model 1904 software
revision number will be displayed, for example, 20, 21, 22 etc. To continue in the Programming Mode, press
one of the Option Numbers listed below or press "DELETE" to exit the Programming Mode.
OPTION NUMBER 13_1 to 9: Display Rotation Time
While in the Programming Mode press " 13 " on the Keypad, the number 13_3 will be displayed indicating
that your Model 1904 Keypad was shipped with a [are-programmed display rotation time of 3 seconds. Each
number entered into the system will be displayed for 3 seconds before rotating to the next entered number.
Should you wish to increase or decreasethetime between displayed numbers, select and enter any number from
1 to 9 seconds on the Keypad and press "ENTER." The display rotation will be the number of seconds (1. 9)
you selected.
OPTION NUMBER 13_0 : Manual Advance Option
It is also possible to program your Model 1904 to store a series of numbers then display them in sequential
order on demand. It will start with the first number entered and rotate to the next number each time the
"DELETE" key is pressed. This option is useful in a song service for displaying the next song without the
system automatically rotating the songs. To select this feature, press "13_0,” "ENTER" on the Keypad . The
display rotation time is now Zero or turned OFF. To reset the display rotation time, see Option 13 above.
m: To display numbers as they were entered you must turn off the sort routine using OPTION 21.)
OPTION NUMBER 14_0 to 9 .' Auto Delete Option
The Model 1904 Keypad will normally display any entered number until manually deleted by pressing the
"DELETE" key. The Auto Delete Option will automatically delete each entered number after 1 to 9 minutes.
Should you wish to enable the Auto Delete Option, enter the Programming Mode, and then press "14" on the
Keypad. The Model 1904 Keypad reads 1 470 indicating the Auto Delete is "OFF. " Select and press any number
from 1 to 9 minutes and press “ENTER." The Model 1904 will now Automatically Delete each entered number
after the minutes entered have elapsed, for example, 14_3 - 3 minutes.
OPTION NUMBER 1770 or 1 : Keypad Beeper Option
The Model 1904 has a built-in beeper that "clicks" every time a keyboard entry is made. If you wish to disable
this feature, press "17" on the Keypad while in the ProgrammingMode, then press "1," "ENTER. " The beeper
is now disabled. To reactivate the beeper, simply press "1770" " ENTER'I while in Programming Mode.
OPTION NUMBER 19_: Reset to Factory Options
At any time while in the Programming Mode, the Model 1904 can be reset to the Factory Options by
pressing "19." The Keypad display will blink once and then display the current revision number indicating
the Factory Options have been reset.
(Continued on page 16) 10
OPflON NUMBER 21__0 or 1 : Number Sort Option
This option lets the user decide whether or not to display the numbers in numerical order or the order in
which they were entered. To disable the number sort, press "2 1_1 “ on the Keypad While in the Programming
Mode, then "ENTER." The sort is now disabled. This will set the number option to display the numbers in
the order that they were entered. To enable the sort press "21_0","ENTER" and the sort routine will again
sort the numbers.
Index
Memory Size
Display Features 7 Maximum Number of Pages 2
Display SPECIFICATIONS 3 Model 904 Keypad
Displays. See Remote Displays Model 904 SPECIFICATIONS 2
Mounting
E 904 Keypad 5
Error codes 8 Remote Display 5
F l’
Fuse 2, 8 Pte-Installation Instructions 4
Programming 9
I Programmmg Instructions 9
Illustrations R
904 Case Dimensions 2 1
920, 930 & 940 Case 3 Remote Display Features 7
Mounting 904 Keypad 4 Rem“? D'SPIZ’YS
Remote Display Dimensions 3 M”“"‘"“ N“““’" 7
Installation Location 5 T
Instalh'ng
AC Power 5 TROUBLE-SHOOTING CHART 8
Remote Display 5
11

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Create Date                     : 2001:07:10 03:15:41
Producer                        : Acrobat Distiller 4.0 for Windows
Author                          : jsoscia
Title                           : 13073.pdf
Modify Date                     : 2001:07:10 03:15:43-04:00
Page Count                      : 11
EXIF Metadata provided by EXIF.tools
FCC ID Filing: N8X1904

Navigation menu