Micron Electronics PRS GSM Tracker User Manual AIR2011 Interface Protocol

Micron Electronics LLC. GSM Tracker AIR2011 Interface Protocol

Users Manual

1                    PRIME PR100  User Manual    Revision: 1.00    Document Title PR100 User manual Version 1.00 Finale Date 2013-10-25 Status Released Document Control ID PR100
2  Contents   1 Introduction....................................................................................................................................3 2 Product Overview ..........................................................................................................................3 2.1 Appearance..........................................................................................................................3 2.2 Buttons/Mini USB Interface Description ............................................................................3 2.3 LED Description .................................................................................................................4 3 Getting Started ...............................................................................................................................5 3.1 Parts List .............................................................................................................................5 3.2 Battery Charging .................................................................................................................5 3.3 PR100 Data Cable ...............................................................................................................5 3.4 How to insert SIM Card ......................................................................................................6 3.5 Power on/Power off.............................................................................................................7 3.6 Calls ....................................................................................................................................7 4 Trouble shooting and Safety info ...................................................................................................8 4.1 Trouble shooting .................................................................................................................8 4.2 Safety info ...........................................................................................................................8 5. Warning statement.........................................................................................................................8
3  1 Introduction PR100  is  a  mobile  phone which  mainly  is  used  for  emergency dialing  with  GSM  frequencies 850/900/1800/1900. Based on the embedded wireless protocol, PR100 can communicate with the backend server through GPRS/GSM network, and transfer reports of emergency, gsm information and scheduled power level etc… Service provider is easy to setup their processing platform based on the functional wireless protocol.   2 Product Overview   2.1 Appearance    Figure 1-1   2.2 Buttons/Mini USB Interface Description   Button /Mini USB Interface Description KEY/interface Description Power Key Power on PR100 and initiate an emergency call. Note: Power off PR100 is automated whilst 5 minutes later after the call.
4   Mini USB interface Connect  a  5V  DC  adapter can  power  on  PR100  and  charge  the  internal battery. Backend server developer or administrator can use the data cable to configure PR100. Reset Key Click  the  key will turn  off  internal VBAT  when OS  is abnormal,  and  then press Power Key to restart PR100.    2.3 LED Description    Figure 1-2 There are red and blue LED lights in PR100 device, the description as following.  Event Light State Power off Solid red Power on and normal Solid red AND solid blue Fully charged Slow flashing blue In charging Slow flashing red SOS call in progress Solid red Normal call in progress Solid blue Call failed (i.e. no signal) Solid red AND solid blue Low battery Fast flashing red
5  3 Getting Started   3.1 Parts List   Name Picture Remark PR100 device    The GSM/GPRS phone. AC-DC Power Adapter    It  is  used  to  charge  the  internal  battery  of PR100. PR100 Data and charger Cable  It  is  the  USB  data  cable which  can  be  used for firmware upgrading and configuration. It also includes the charger interface on the PR100.    3.2 Battery Charging   The following items are suggestion for battery charge, please pay more attention.   Please connect AC-DC power adapter with PR100 device.   Insert the AC-DC power adapter into the power socket.   During the charging process, the LED light will slow flash red. When the battery is fully charged, the LED light will be slow fashing blue.   You can also charge the battery using USB cable which  connects PR100 device with the PC.   Charging will last about less than two hours. Note: If the PR100 device is firstly used, please make sure the battery is fully charged, which will make the life of battery much longer.   3.3 PR100 Data Cable   PR100 Data Cable is a cable with a Mini USB connector. The USB data cable is used for firmware update or configuration and can be used for
6  charging at the same time.    Figure 2-1   3.4 How to insert SIM Card    Figure 2-2 Step1: Screw off and pull out the cover of SIM card. Step2:  insert  the  SIM  card  into  the  slot  of  the  device according  to  the  direction  as shown. Step3: push the cover back.
7  3.5 Power on/Power off      Power on: Figure 2-3   Press the Power key at least 3 seconds and release it to power on PR100 device. Note that, the LED light will be solid red and solid blue.   Power off:  Power off is automated whilst 5 minutes later after the call.     3.6 Calls   To make a call or answer a call, press the Power key once, the call can also be hung up by pressing the Power key. Note1: Be sure that the PR100 device is powered on before a call. Note2: The PR100 device can only support voice function via a speaker, and does not support the position against the ear or headset.
8  4 Trouble shooting and Safety info   4.1 Trouble shooting    Trouble Possible Reason Solution Messages can’t be reported to the backend server by GPRS. The SIM card in PR100 doesn’t support GPRS. Try a GPRS supported SIM card. APN is wrong. Some APN can not visit the internet directly. Ask the network operator for the right APN. The IP address or port of the backend server is wrong. Make sure the IP address for the backend server is an identified address in the internet.   4.2 Safety info   The following items are suggestion for safety use, please pay more attention.   Please do not disassemble the device by yourself.   Please do not put the device on the overheating or too humid place, avoid exposure to direct sunlight. Too high temperature will damage the device or even cause the battery explosion.   Please do not use PR100 on the airplane or near medical equipment. 5. Warning statement  This  device complies with  Part  15  of  the  FCC  rules.  Operation  is  subject  to  the following  two  conditions:  1)  this  device  may  not  cause  harmful  interference,  and  2)  this device   must   accept   any  interference   received,   including   interference   that  may  cause undesired operation.   RF exposure information: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment。This equipment should be installed and operated with minimum distance 20cm between the radiator & your body。   Changes  or  modifications  not   expressly  approved   by  the  party  responsible  for compliance could void the user’s authority to operate the equipment.

Navigation menu