IC-3USB Interface Kit
Installation Guide
Unpacking
You should find the following items:
• 9-to-15-Pin Adapter (61-000043-03)
• USB-to-Serial Cable (61-000044-02)
You will also need:
• A Microscan reader
• A host computer with Windows 7, Vista, XP, or 2000
• Microscan Tools Drive (37-000010-01)

Step 1 —Assemble Cabling
Attach the plug end of the pin adapter to the reader’s
serial cable connector and the USB-to-Serial Cable.
USB-to-Serial Cable

Pin Adapter

Step 2 — Install IC-3USB Driver
(Windows 7 and Vista)
1. Insert the Microscan Tools Drive and click
Accessories in the navigation column at the left
of the screen.
2. Click IC-3USB Driver (Windows 7) or IC-3USB
Driver (Windows Vista) to open the driver folder.
3. Open the zip file and double-click the
UC232A_Setup_V1.0.074.exe (Windows 7) or
UC232A_windows vista.exe (Vista) file to
launch the Setup Wizard.
4. Click Next when the Setup Wizard’s welcome
screen appears.

Power: Reader current + 90mA.

Important: Do not use the IC-3USB with Quadrus
MINI Series imagers or MS-4 imagers.

83-210029 Rev F

Step 2 — Install IC-3USB Driver
Step 2 — Install IC-3USB Driver
(Windows 7 and Vista – cont.)
(Windows XP and 2000)
5. When you are ready to install the program,
click Install.
6. The Setup Wizard will display a progress bar
during installation. At the end of installation, the
Setup Wizard will display a screen stating that
installation is complete. Click Finish to close
the Setup Wizard.

1. Insert the Tools Drive and click Accessories
in the navigation column at the left of the screen.
2. Click IC-3USB Driver (Windows XP) or IC-3USB
Driver (Windows 2000) to open the driver folder.
3. Open the zip file to launch the Setup Wizard.
4. Click Next when the Setup Wizard’s welcome
screen appears.

Step 2 — Install IC-3USB Driver
(Windows XP and 2000 –
cont.)
5. If you are using Windows XP, a compatibility
warning may appear. Click Continue Anyway to
begin installation.
6. When installation is complete, the InstallShield
Wizard Complete screen will appear. Click Finish
to close the wizard.

Step 3 — Connect IC-3USB
Windows 7 and Vista
Connect the USB socket end of the IC-3USB cable
to a USB port on the host computer. A confirmation
dialog will appear, stating that the driver has been
installed and that the IC-3USB is ready to use.

Step 4 — Locate Virtual COM Port
The installation wizard creates a virtual COM port that
will appear automatically whenever you insert the IC-3USB.
To verify correct installation, go to your Windows
Device Manager and click on Ports to see the virtual
port (highlighted below).

Step 5 — Start ESP
When you run ESP after installing the IC-3USB
driver, you will notice that a new COM port is now
available to ESP.

Windows XP and 2000
1. Connect the USB socket end of the IC-3USB
cable to a USB port on the host computer.
2. The Found New Hardware Wizard will appear
and ask if you want to connect to Windows
Update to search for software. Select No, not
this time and click Next.
3. On the next screen, select Install the software
automatically (Recommended) and click Next.
4. If you are using Windows XP, a compatibility
warning may appear. Click Continue Anyway
to begin installation.
5. When installation is complete, the Completing
the Found New Hardware Wizard screen will
appear. Click Finish to close the wizard.

Copyright ©2015 Microscan Systems, Inc.

Select the highest available COM port on the list and
continue your reader setup in ESP.
If you remove the IC-3USB from the USB port, the
associated COM port will disappear.
Caution: Do not re-insert the IC-3USB into your USB
port without first restarting the computer. Doing so may
cause the computer to lose other COM port connections
and force you to reboot your computer.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Mode                       : UseNone
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Creator Tool                    : FrameMaker 8.0
Modify Date                     : 2015:04:24 15:29:53-07:00
Create Date                     : 2003:02:12 13:34:05Z
Metadata Date                   : 2015:04:24 15:29:53-07:00
Format                          : application/pdf
Title                           : IC-3USB Interface Kit Installation Guide
Creator                         : 
Producer                        : Acrobat Distiller 8.1.0 (Windows)
Document ID                     : uuid:fafc2e14-51e5-4ec5-822b-e0bdea2f71ff
Instance ID                     : uuid:e37aadb2-eec8-496e-968d-29b1eee7b6d3
Page Count                      : 2
Page Layout                     : SinglePage
Warning                         : [Minor] Ignored duplicate Info dictionary
EXIF Metadata provided by EXIF.tools

Navigation menu