CONNECTION INSTRUCTIONS
1. Mount the IB-890 Wiring Box.
2. Remove the Wiring Box Plug, and connect
the wiring as required.
3. Apply power to the wiring box and confirm that the
LED lamp next to the right side power terminal is green.
The lamp is green if polarity is correct, red if reversed.
4. Turn off power, then plug in the flex strip to scanner
as shown below.
MS-890
Scanner
Flex Strip
Wiring Box
5. Set the scanner squarely on wiring box,
as shown below.
6. Then, tighten four (4) retaining screws to
secure scanner to wiring box.
Scanner Mounting
Screws (4)
Wiring Box Plug