Sp056d0809 Qx 870spec

2009-09-02

: Microscan Qx-870Spec qx-870spec 6594be84-55de-4e06-81d3-ca64956a1a5c _att

Open the PDF directly: View PDF PDF.
Page Count: 2

Industrial Raster
Laser Scanner
The QX-870 laser scanner partners the latest
technologies in barcode reading and connectivity
into an easy to use solution for barcode track,
trace and control applications. Simple to set up
and deploy, it features a programmable sweeping
raster to read multiple codes, in varying loca-
tions, even if they are damaged or mis-aligned.
With plug and play setup and the most
aggressive decode algorithms available, the
QX-870 an ideal laser scanner for any industrial
application.
High Performance
Aggressive decoding capa-
bilities allow reliable read-
ing of barcodes out to 30”
(762 mm), at up to a 10”
(254 mm) beam width.
Intelligent Raster
In addition to sweep angle
and speed controls, the
QX-870 features a program-
mable raster with intelligent
auto framing technology.
Advanced software will
automatically frame the
raster height and width
of the laser to match the
barcode, allowing selective
targeting of codes within a
single read cycle.
Ethernet Protocols
The QX-870 includes
optional embedded Ethernet
TCP/IP and EtherNet/IP for
high speed communication.
Application Examples
•Any industrial environment
from light to heavy duty
Automotive assembly
Packaging and sortation
Electronics production
•Embedded within machinery
QX–870
QX–870: Available Codes
ESP®Easy Setup Program: Single-point software solution
provides quick and easy setup and configuration of all
Microscan readers.
EZ Button: This performs reader setup and configuration
with no computer required.
Visible Indicators: Performance indicators include “good
read” green flash and LEDs.
Sweeping Raster: This programmable feature enables
the reader for multiple symbols at varying distances and
locations.
QX Platform: Quick Connect system and X-Mode technol-
ogy combine to provide simple connectivity, networking,
and high performance decoding.
QX–870: At a Glance
For more information on this product, visit www.microscan.com.
• Scans/second: 300 to 1400
• Read Range: 1 to 30” (25 to 762 mm)
Optional Embedded Ethernet TCP/IP & EtherNet/IP
• IP65 Enclosure
X-Mode Technology
Decodes damaged,
poorly printed, or mis-
aligned codes
Ensures high read rates
and throughput
Quick Connect System
M12 Ultra-Lock™
connectors and cordsets
Plug and play setup
Single or multi-scanner
solutions
Linear All Standard
Stacked MicroPDF PDF417 GS1 Databar
Intelligent
Raster
EZ Button
Setup
IP65
Enclosure
Optional Embedded Ethernet &
Ultra-Lock Connectors
SCANNING PARAMETERS
Mirror Type: Rotating, 10-faceted
Scan Rate: Adjustable from 300 to 1400
scans/sec. Scan Width Angle: Typically 60°
Pitch: ±50° max. Skew: ±40° max.
Label Contrast: 25% min. absolute dark to
light differential at 655 nm wavelength
Raster Mirror Performance:
PROTOCOLS
Point-to-Point, Point-to-Point w/RTS/CTS,
Point-to-Point w/XON/XOFF, Point-to-Point
w/RTS/CTS & XON/XOFF, Multidrop, Daisy
Chain, User-De ned Multidrop, Ethernet
TCP/IP, EtherNet/IP
PIN ASSIGNMENTS2
Connector A (Serial)
M12 12-pin plug:
ENVIRONMENTAL
Enclosure: IP65 rated
Operating Temperature: 0° to 50° C
(32° to 122° F )
Storage Temperature: -50° to 75° C
(-58° to 167° F )
Humidity: Up to 90% (non-condensing)
EMISSIONS
Heavy Industrial: EN 61000-6-2:2005
Radiated Emissions: EN 55022:2006
Class A 30-1000 MHz
Conducted Emissions: EN 55022:2006
Class A .15-30 MHz
COMMUNICATION INTERFACE
Interface: RS-232/422/485 and/or Ethernet
SYMBOLOGIES
Standard: Code 39, Codabar, Code 93,
Interleaved 2 of 5, Code 128, PDF417,
Micro PDF417, Pharmacode, UPC, GS1 Databar
Applications Standard: UCC/EAN-128, AIAG
LASER LIGHT
Type: Laser diode
Output Wavelength:
655 nm nominal
Operating Life: 50,000 hours @ 25° C
Safety Class: Visible laser: Class 2
MECHANICAL
Height: 4.29” (109 mm)
Width 3.74” (95 mm)
Depth: 1.76” (45 mm)
Weight: 16 oz. (453 g)
DISCRETE I/O
Input 1: (Trigger/New Master): Optoisolated,
4.5–28V rated, (13 mA at 24 VDC) New Master
is (–) to signal ground
Outputs (1, 2 & 3): Optoisolated,
1–28V rated, (ICE <100 mA at 24 VDC,
current limited by user)
SAFETY CERTIFICATIONS
CDRH, FCC, CE, CB, BSMI (compliant)
ROHS/WEEE COMPLIANT
ISO CERTIFICATION
Certi ed ISO 9001:2000 Quality Management
System
©2009 Microscan System, Inc. SP056D 08/09
Read Range and other performance data is determined using high quality
Grade A symbols per ISO/IEC 15415 and ISO/IEC 15416 in a 25° C
environment. For application-speci c Read Range results, testing should
be performed with symbols used in the actual application. Microscan
Applications Engineering is available to assist with evaluations. Results
may vary depending on symbol quality. Warranty–One year limited warranty
on parts and labor. Extended warranty available.
READ RANGES1
QX870 Industrial Raster Laser Scanner
Specifi cations and Options
Microscan Systems Inc.
Tel 425 226 5700 / 800 251 7711
Fax 425 226 8250
Microscan Europe
Tel 31 172 423360 / Fax 31 172 423366
Microscan Asia Pacifi c
Tel 65 6846 1214 / Fax 65 6846 4641
www.microscan.com
Product Information: info@microscan.com
Auto ID Support: helpdesk@microscan.com
Vision Support: visionsupport@microscan.com
NERLITE Support: nerlitesupport@microscan.com
IEC 60825-1 Ed. 2 (2007)
655nm 1.75mW 40~186µs
LOW DENSITY RANGE DATA
Narrow-bar-width Read Range
.0075" (0.191 mm) 10 to 12" (254 to 305 mm)
.010" (0.254 mm) 7 to 16" (178 to 406 mm)
.015" (0.381 mm) 6 to 19" (152 to 483 mm)
.020" (0.508 mm) 5 to 22" (127 to 558 mm)
.040" (1.02 mm) 4 to 30" (102 to 762 mm)
1Ranges based on a Grade A, Code 39 label. If your read range falls
outside the above ranges, please call Microscan. Data subject to change.
MEDIUM DENSITY RANGE DATA
.0075" (0.191 mm) 2.5 to 5.5" (64 to 140 mm)
.010" (0.254 mm) 1.5 to 7.0" (38 to 178 mm)
.015" (0.381 mm) 1.5 to 8.5" (38 to 216 mm)
.020" (0.508 mm) 1.5 to 11" (38 to 280 mm)
.030" (0.762 mm) 1.0 to 12" (25 to 304 mm)
HIGH DENSITY RANGE DATA
.0033" (0.084 mm) Call Microscan
.005" (0.127 mm) 4 to 5.0" (102 to 127 mm)
.0075" (0.191 mm) 3.5 to 6.75" (89 to 171 mm)
.010" (0.254 mm) 3.25 to 8" (82 to 203 mm)
.015" (0.381 mm) 3.25 to 9" (82 to 228 mm)
Connector B (Serial)
M12 12-pin socket:
Note: Data subject to change.
Connector B (Ethernet)
M12 8-pin socket:
ELECTRICAL
Power Requirement: 10–28 VDC, 200 mV
p-p max ripple, 270mA at 24 VDC (typ.)
Raster sweep angle Maximum sweeps per second
1°–10° 80
11°–20° 60
21°–34° (max.) 40
35°–36° (max.) 20
QX-870
QX-870
QX-870
4.29in
108.8mm
3.74in
95mm
1.40in
35.6mm
2.50in
63.6mm
2X M4x0.7
6mm DEPTH
MIN
2.50in
63.6mm
1.40in
35.6mm
3X M4x0.7
7mm
DEPTH
MIN
Connector P/M (Serial)
M12 12-pin plug:
Pin Assignment
9 N/C
10 N/C
2 Power
7 Ground
1 N/C
8 N/C
3 N/C
4 N/C
5 422/485 TxD (+)
11 422/485 TxD (–)
6 422/485 RxD (+)
12 422/485 RxD (–)
Pin Assignment
9 Host RxD
10 Host TxD
2 Power
7 Ground
1 Trigger
8 Input Common
3 Default
4 New Master
5 Output 1
11 Output 2
6 Output 3
12 Output Common
Pin Assignment
9 TxD/RTS
10 RxD/CTS
2 Power
7 Ground
1 Trigger
8 Input Common
3 Terminated
4 Input 1
5 422/485 TxD (+)
11 422/485 TxD (–)
6 422/485 RxD (+)
12 422/485 RxD (–)
Pin Assignment
1 Terminated
2 Terminated
3 Terminated
4 TX (–)
5 RX (+)
6 TX (+)
7 Terminated
8 RX (–)
Connector T (Trigger)
M12 4-pin socket:
Pin Assignment
1 + 10 to 28 V
2 Trigger/New Master/
Input 1 Common
3 Ground
4 Trigger
2Note: Detailed connector pinout
information is available in the
User’s Manual.