Configuration Guide
Hardware Required
Item

Description

Part Number

1

QX Hawk Industrial Imager

FIS-6800-XXXXG

2

QX-1 Interface Device

98-000103-01

3

QX Cordset, Common, M12 12-pin Plug to M12 12-pin Socket, 1 m

61-000162-01

4

QX Cordset, Host, Serial, M12 12-pin Plug to DB9, 1 m

61-000152-01

5

QX Cordset, Host, Serial, M12 12-pin Socket to DB9, 1 m

61-000153-01

6

QX Power Supply, M12 12-pin Socket, 1.3 m

97-000003-01

7

QX Cordset, Host, Ethernet, M12 8-pin Plug to RJ45, 1 m

61-000160-01

8

QX Cordset, M12 12-pin Plug to MS-Connect 5100, 3 m

61-000161-01

9

QX Cordset, M12 12-pin Plug / M12 12-pin Socket to MS-Connect 210, RS-232, 2 m

61-000158-01

10

QX Photo Sensor, M12 4-pin Plug, NPN, Dark On, 2 m

99-000020-02

Note: Additional cordsets available in the Microscan Product Pricing Catalog.

Pin Assignments
A is a serial M12 12-pin plug.
B is a serial M12 12-pin socket or an Ethernet M12 8-pin socket.
RS-422/485 RxD (–)

Output 2

Input
Common

Default

New Master

Power

Output 1

Terminated

TX (–)

RS-422/485 TxD (–)

Output Common

Terminated

B (Ethernet) M12 8-pin Socket

B (Serial) M12 12-pin Socket

A (Serial) M12 12-pin Plug

Terminated

Terminated
Input 1

RS-232 RxD

RX (–)

Terminated

RX (+)

Power

RS-422/485
TxD (+)

Ground
Input Common

RS-232 RxD/
RS-232 CTS

RS-422/485
RxD (+)

Trigger

TX (+)

Trigger

Ground

RS-232
TxD

Output 3

RS-232 TxD/
RS-232 RTS

QX-1 Interface
Device (Top View)
Connector T on the QX-1 Interface Device is the trigger connector.
Connectors 1, 2, and 3 can be used to bus power and data as required by the application.
Trigger

P

+10-28V

Ground

T

Trigger/New Master / Input 1 Common

Trigger Connector 4-pin Socket

Standalone Configuration
Serial with QX-1

Ethernet with QX-1

Copyright ©2010 Microscan Systems, Inc.

Serial with MS-Connect 210

P/N 83-217011 Rev A

QX Hawk Configuration

Daisy Chain Configuration
Serial with QX-1

Ethernet with QX-1

Important: Do not attempt to power more than four imagers with a single power supply in a daisy chain configuration. Add a
QX-1 and one power supply for every four additional imagers in the daisy chain.

Multidrop Configuration
Multidrop Network with MS-Connect 5100

QX Hawk Accessories
Adapter Plate Kit, QX Hawk
Right Angle Mirror Kit, QX Hawk
Window Replacement, QX Hawk
15° Lens Kit, QX Hawk
30° Lens Kit, QX Hawk
45° Lens Kit, QX Hawk
L-Bracket Kit, QX Series (can also be used with QX-830 and QX-870)
Demo Kit, QX Hawk (includes one each of Lens Kits and mounting)
Microscan Tools CD
Note: Additional accessories are available in the Microscan Product Pricing Catalog.

98-000143-01
98-000144-01
98-000146-01
98-000147-01
98-000147-02
98-000147-03
98-000148-01
98-000149-01
37-000001

QX Hawk Configurable Part Numbers
QX Hawk part numbers follow the format FIS-6800-CLSYG:
C = 0 for RS-422, 1 for Ethernet, 2 for USB, 3 for CAN;
L = 0 for C-Mount, 1 for 15°, 2 for 30°, 3 for 45°;
S = 0 for CCD, 1 for CMOS;
Y = 0 for Microscan Standard, 1 for Custom;
G = RoHS-Compliant

Copyright ©2010 Microscan Systems, Inc.

www.microscan.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Mode                       : UseNone
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Creator Tool                    : FrameMaker 8.0
Modify Date                     : 2009:12:15 12:10-08:00
Create Date                     : 2005:03:28 11:26:25Z
Metadata Date                   : 2009:12:15 12:10-08:00
Format                          : application/pdf
Title                           : QX Hawk Industrial Imager Configuration Guide
Creator                         : 
Producer                        : Acrobat Distiller 8.1.0 (Windows)
Document ID                     : uuid:aff97f6f-4aaa-46c6-8194-12d0ea65a08a
Instance ID                     : uuid:3bb873d2-07f0-4752-a7fe-493afdb555fb
Page Count                      : 2
Page Layout                     : SinglePage
Warning                         : [Minor] Ignored duplicate Info dictionary
EXIF Metadata provided by EXIF.tools

Navigation menu