Downgrading the Speed and Decoder Settings of MicroHAWK ID Products for
Demonstrational Purposes
The  command in Microscan’s ESP® Software and WebLink User Interface allows a Microscan
representative (staff or partners) the ability to demonstrate the differences in performance for specific
licensed feature options in the MicroHAWK Barcode Reader platform (in this case, Speed and Decoder
options). It is NOT intended for distribution as a trial license to customers. The command does not
upgrade to features beyond those that are currently licensed; the command can only downgrade currently
licensed settings or override to the maximum licensed settings.
Capabilities
 Ability to “downgrade” from High-Speed frame acquisition (maximum for the unit’s sensor type) to
Standard Speed (limited to 10 FPS)
 Ability to “downgrade” the Decoder from X-Mode (Damaged and/or DPM symbols) to Plus (highcontrast 1D/2D) to Standard (high-contrast 1D only)
 No ability to “upgrade” beyond what is currently licensed
 Changes take effect immediately
 Changes are not persistent through a power-cycle (i.e., power-cycling the unit will reset the unit to
the default maximum feature settings)
Syntax
 
Speed
maxFPS:

Decoder
decoderType:

0 = standard mode (acquisition capped at 15 fps)
1 = high-speed mode

0 = 1-D
1 = 2-D
2 = X-Mode

Examples
 Assuming a MicroHAWK ID unit with High-Speed and X-Mode licenses:




Unit runs at max 10 FPS, decodes 1D symbols only
Unit runs at max 10 FPS, decodes 1D and 2D symbols
Unit runs at max 10 FPS, X-Mode decoder enabled





Unit runs at max sensor FPS, decodes 1D symbols only
Unit runs at max sensor FPS, decodes 1D and 2D symbols
Unit runs at max sensor FPS, X-Mode decoder enabled

Notes
 Attempting to set a parameter with an out-of-range value results in error 57 returned
 Attempting to set a parameter with a value that exceeds the current licensed setting results in
error 57 returned
 As expected, setting a parameter that does not meet the criteria of the application may result in
the unit becoming unable to read the symbol. Example: When using WebLink and a fully-licensed
MicroHAWK ID unit (High-Speed and X-Mode licenses enabled) to decode a 2D symbol, issuing
the command  will cause the unit to immediately lose the ability to read the symbol
because the Decoder will be set to Standard (1D symbols only).

M I C R O S C AN S Y ST E M S, I N C . © 2 0 1 5



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 1
Language                        : en-US
Tagged PDF                      : Yes
Title                           : Microscan
Author                          : Microscan
Creator                         : Microsoft® Word 2013
Create Date                     : 2016:05:17 14:57:16-07:00
Modify Date                     : 2016:05:17 14:57:16-07:00
Producer                        : Microsoft® Word 2013
EXIF Metadata provided by EXIF.tools

Navigation menu