Midmark 9A429T1 Exam Table w/ Remote Control Transmitter User Manual manual
Midmark Corporation Exam Table w/ Remote Control Transmitter manual
Midmark >
manual
Compliance Information FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Any modifications to this product may violate the rules of the Federal Communications Commission and make operation of the product unlawful. Declaration of Conformity Midmark Corporation declares that 9A429001 thru 9A429004 conform to the applicable requirements of the Radio Equipment & Telecommunications Equipment Directive 1999/5/EC, Annex II Serial Number: ALL to present Quality Assurance Manager Don Carr Midmark Corporation 60 Vista Drive P.O. Box 286 Versailles, OH 45380 U.S.A. Limited Warranty SCOPE OF WARRANTY Midmark Corporation (“Midmark”) warrants to the original purchaser its new Alternate Care products and components (except for components not warranted under “Exclusions”) manufactured by Midmark to be free from defects in material and workmanship under normal use and service. Midmark’s obligation under this warranty is limited to the repair or replacement, at Midmark’s option, of the parts or the products the defects of which are reported to Midmark within the applicable warranty period and which, upon examination by Midmark, prove to be defective. APPLICABLE WARRANTY PERIOD The applicable warranty period, measured fromt he date of delivery to the original user, shall be one (1) year for all warranted products and components. EXCLUSIONS This warranty does not cover and Midmark shall not be liable for the following: (1) repairs and replacements because of misuse, abuse, negligence, alteration, accident, freight damage, or tampering; (2) products which are not installed, used, and properly cleaned as required in the Midmark “Installation” and or “Installation / Operation Manual for this applicable product. (3) products considered to of a consumable nature; (4) accessories or parts not manufactured by Midmark; (5) charges by anyone for adjustments, repairs, replacement parts, installation, or other work performed upon or in connection with such products which is not expressly authorized in writing in advance by Midmark. EXCLUSIVE REMEDY Midmark’s only obligation under this warranty is the repair or replacement of defective parts. Midmark shall not be liable for any direct, special, indirect, incidental, exemplary, or consequential damages or delay, including, but not limited to, damages for loss of profits or loss of use. General Information Intended Use 625 Wireless Controls 9A429 Authorized CE Representative Countries in the EEC should direct all questions, incidents, and complaints to Midmark’s authorized CE Representative listed below: Promotal 22, Rue de St. Denis 53500 Ernee, FRANCE Phone: 33-2-430-517-76 Fax: 33-2-430-569-10 Calling for Service If service is required, contact your Midmark dealer. To contact Midmark directly: 1-800-MIDMARK (1-800-643-6275) Monday-Friday 8:00 am until 5:00 pm (EST) www.midmark.com NO AUTHORIZATION No person or firm is authorized to create for Midmark any other obligation or liability in connection with the products. 077-0589-00 User’s Guide This product is intended to control patient positioning while providing better patient access by eliminating the cord from the foot control. THIS WARRANTY IS MIDMARK’S ONLY WARRANTY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. MIDMARK MAKES NO IMPLIED WARRANTIES OF ANY KIND INCLUDING ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE, THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF DEFECTIVE PARTS. This guide outlines basic operation of the wireless hand / foot control and the associated base station. If service is required, contact your authorized Midmark dealer. Dealer (name / phone): __________________________________ __________________________________ __________________________________ __________________________________ Midmark Corporation 60 Vista Drive Versailles, OH 45380-0286 Phone: 937-526-3662 Fax: 937-526-5542 www.midmark.com Date of Purchase: __________________ © Midmark Corporation 2009 003-1945-00 Rev. A Association Procedure Specifications The wireless controller will only function with the chair it has been “associated” with. This prevents unwanted movement in locations with more than one chair. Each wireless controller’s association is preset at the factory. This procedure is only required in the event of a malfunction, if a new controller is purchased, or if you are attempting to use the controller with a chair other than the one it was originally associated with. Range of Operation.............. 20 ft. (6 m) radius Batteries: Hand Control..................................AA (qty. 2) Foot Control...................................AA (qty. 2) Association Procedure: A) Disconnect power to the table for at least 3 seconds. B*) Reconnect power, then press & hold the Stop & Home buttons on the wireless controller, until you hear three “beeps”. * Note: Step B must be performed within 10 seconds of Step A. C) Check for proper operation of wireless controller. D) If associating a hand and foot control, repeat procedure using the other wireless controller. MA771100i Home Stop Troubleshooting When any control button is pressed, that controller sounds a single “beep”. (All functions operate) Cause: Low battery Solution: Replace batteries When any control button is pressed, nothing happens. (No “beeps”, no movement, etc.) Stop Cause: 1. Batteries completely dead 2. Wireless controller has lost “association” to chair Solution: 1. Replace batteries 2. Perform Association Procedure* The wireless controllers will only function with the ... chair they have been “associated” with. This prevents unwanted movement in locations with more than one chair. If further service is required, contact your authorized Midmark dealer.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Extract, Print high-res Tagged PDF : Yes Page Mode : UseThumbs XMP Toolkit : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:39 Instance ID : uuid:93d9d7e8-9497-4d86-97e6-183d3bf45407 Document ID : adobe:docid:indd:c97bc6a8-63c8-11dd-ab26-cb0fe4271e5d Rendition Class : proof:pdf Derived From Instance ID : c97bc6a7-63c8-11dd-ab26-cb0fe4271e5d Derived From Document ID : adobe:docid:indd:dbc0df2f-ba08-11dc-a348-a6bf020424b0 Manifest Link Form : ReferenceStream, ReferenceStream Manifest Placed X Resolution : 300.00, 300.00 Manifest Placed Y Resolution : 300.00, 300.00 Manifest Placed Resolution Unit : Inches, Inches Manifest Reference Instance ID : uuid:4e0ad340-f3b8-11dd-963c-daf373356a54, uuid:4e0ad340-f3b8-11dd-963c-daf373356a54 Manifest Reference Document ID : uuid:2356369566F1DD11A19BC8DAF161ECFB, uuid:2356369566F1DD11A19BC8DAF161ECFB Create Date : 2009:09:09 08:48:20-04:00 Modify Date : 2009:12:17 15:03:44-06:00 Metadata Date : 2009:12:17 15:03:44-06:00 Creator Tool : Adobe InDesign CS3 (5.0.2) Format : application/pdf Producer : Adobe PDF Library 8.0 Trapped : False Has XFA : No Page Count : 2 Page Layout : SinglePage Creator : Adobe InDesign CS3 (5.0.2)EXIF Metadata provided by EXIF.tools