Mikrotikls SIA RB711UA-5HND 2x2 MIMO 802.11 DIGITAL TRANSMISSION SYSTEM ROUTER User Manual

Mikrotikls SIA 2x2 MIMO 802.11 DIGITAL TRANSMISSION SYSTEM ROUTER Users Manual

Contents

Users Manual

Download: Mikrotikls SIA RB711UA-5HND 2x2 MIMO 802.11 DIGITAL TRANSMISSION SYSTEM ROUTER User Manual
Mirror Download [FCC.gov]Mikrotikls SIA RB711UA-5HND 2x2 MIMO 802.11 DIGITAL TRANSMISSION SYSTEM ROUTER User Manual
Document ID1527122
Application IDQBSo1YG52JF2RzBXxO4EzQ==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize29.97kB (374604 bits)
Date Submitted2011-08-22 00:00:00
Date Available2011-08-22 00:00:00
Creation Date2011-08-19 13:59:35
Producing SoftwareMicrosoft® Word 2010
Document Lastmod2011-08-19 13:59:35
Document TitleUsers Manual
Document CreatorMicrosoft® Word 2010
Document Author: Normis

RouterBOARD 711UA-5HnD
Quick Setup Guide and Warranty Information
RB711UA-5HnD is a dual chain 5 GHz 802.11n wireless device with one Ethernet port, one USB 2.0 port, and a power jack.
First use


Connect antenna cables to the built in Wi-Fi connectors
Device accepts 8-30V with a passive PoE powered Ethernet cable
or with a power connector to the Power Jack
Powering
The board accepts power with the following modes:


With PoE to ETHER1 port. It accepts 8-30V DC input (at the board;
higher voltage needed to compensate for power loss on long cables; at least 18V suggested) from non-standard (passive) Power
over Ethernet injectors (no power over data lines). The board does
not work with IEEE802.3af compliant 48V power injectors.
Direct input to the power jack 8-30V
Booting process
This device doesn't come fitted with a Serial Port connector, so initial connection has to be done via the Ethernet cable, using
the MikroTik Winbox utility. Winbox should be used to connect to the default IP address of 192.168.88.1 with the username
admin and no password.
In case IP connection is not available, Winbox can also be used to connect to the MAC address of the device. More information here: http://wiki.mikrotik.com/wiki/First_time_startup
In case you wish to boot the device from network, for example to use MikroTik Netinstall, hold the S301 button of the device
when starting it until it beeps and the LED light turns off and RB711 will look for Netinstall servers.
Extension Slots and Ports


One Ethernet port, supporting automatic cross/straight cable correction (Auto MDI/X), so you can use either straight
or cross-over cables for connecting to other network devices. The Ethernet port accepts 8-30V DC powering from a
passive PoE injector.
Built-in 802.11a/n Wi-Fi card (AR9280) with two MMCX/uFL (depends on model) connectors
Buttons and Jumpers


RouterOS reset jumper hole (RESET, marked with a black circle in the diagram above, below S301) – resets RouterOS
software to defaults. Must short circuit the metallic sides of the hole (with a screwdriver, for example) and boot the
device. Hold screwdriver in place until RouterOS configuration is cleared.
S301 – Holding this button during boot time will make RB711 look for Netinstall servers. Release the button after
the LED light goes out.
Operating System Support
Currently tested operating system is MikroTik RouterOS (starting from version v4.16).
See www.routerboard.com for more information. Contact support@mikrotik.com for support questions.
rev. A (23-Mar-2011)
Copyright and Warranty Information
Copyright and Trademarks. Copyright MikroTikls SIA. This manual contains information protected by copyright law. No part
of it may be reproduced or transmitted in any form without prior written permission from the copyright holder. RouterBOARD, RouterOS, RouterBOOT and MikroTik are trademarks of MikroTikls SIA. All trademarks and registered trademarks
appearing in this manual are the property of their respective holders.
Hardware. MikroTikls SIA warrants all RouterBOARD series equipment for the term of one year from the shipping date to be
free of defects in materials and workmanship under normal use and service, except in case of damage caused by mechanical,
electrical or other accidental or intended damages caused by improper use or due to wind, rain, fire or other acts of nature.
If you have purchased your product from a MikroTik Reseller, please contact the Reseller company regarding all warranty and
repair issues, the following instructions apply ONLY if you purchased your equipment directly from MikroTik Latvia
To return failed unit or units to MikroTikls you must perform the following RMA (Return Material Authorization) procedure.
Follow the instructions below to save time, efforts, avoid costs, and improve the speed of the RMA process. Take into account that all goods have one year warranty. Instructions are located on our webpage here: http://rma.mikrotik.com
Manual. This manual is provided “as is” without a warranty of any kind, expressed or implied, including, but not limited to,
the implied warranty of merchantability and fitness for a particular purpose. The manufacturer has made every effort to ensure the accuracy of the contents of this manual, however, it is possible that it may contain technical inaccuracies, typographical or other errors. No liability is assumed for any inaccuracy found in this publication, nor for direct or indirect, incidental, consequential or other damages that may result from such an inaccuracy, including, but not limited to, loss of data or
profits. Please report any inaccuracies found to support@mikrotik.com
Federal Communication Commission Interference Statement (FCC ID: TV7RB711UA-5HND)
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates
uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one of the following measures:




Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority
to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may
cause undesired operation. This device and its antenna must not be co-located or operation in conjunction with any other antenna or
transmitter.
IMPORTANT: Exposure to Radio Frequency Radiation. 20 cm minimum distance has to be maintained between the antenna and the occupational user and 45 cm to general public. Under such configuration, the FCC radiation exposure limits set forth for a population/uncontrolled environment can be satisfied.
List of approved antennas: Omni Directional, MT-482016NA, 9 dBi; Panel, PA 58-24, 24 dBi; Dish, HDDA 5W-32-DP2, 32 dBi
Antenna Installation. WARNING: It is installer's responsibility to ensure that when using the authorized antennas in the United States (or where FCC rules apply); only those antennas certified with the product are used. The use of any antenna other
than those certified with the product is expressly forbidden in accordance to FCC rules CFR47 part 15.204. The installer
should configure the output power level of antennas, according to country regulations and per antenna type. Professional
installation is required of equipment with connectors to ensure compliance with health and safety issues.
See www.routerboard.com for more information. Contact support@mikrotik.com for support questions.
rev. A (23-Mar-2011)

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 2
Language                        : en-US
Tagged PDF                      : Yes
Author                          : Normis
Creator                         : Microsoft® Word 2010
Create Date                     : 2011:08:19 13:59:35+03:00
Modify Date                     : 2011:08:19 13:59:35+03:00
Producer                        : Microsoft® Word 2010
EXIF Metadata provided by EXIF.tools
FCC ID Filing: TV7RB711UA-5HND

Navigation menu