User Guide (Draft)
Description
The Connect module is a removable component that provides a host unit with
connectivity to remotely monitor and control in these ways:
1.
2.
3.
4.
5.
Monitor the host units activity remotely (progress, failures, etc.)
Sync time between host unit and Miovision server
Send scheduled recordings remotely
Automatically identify the units location using GPS
Collect unique identification of nearby wifi-enabled devices for use in
Origin-Destination studies
The Connect module uses wifi and wireless 4G LTE technology to facilitate
communication between itself and Miovision’s cloud-based user portal.
Included in the box
1 x Scout Connect module
Components
No additional components
Required tools
None
Safety recommendations
None
148 Manitou Drive, Suite 101, Kitchener, ON, N2C 1L3 • 1.877.646.8476 •​ ​miovision.com
Installing the Connect Module
Align the Connect module USB plug connectors (3) to the USB ports on the host unit
Gently insert the USB connectors
○ The Connect module is powered by the host unit and will not operate if it
is not powered on
When successfully installed the Connect antenna icon is displayed in the black
Information Bar along the top of the host User Interface.
Technical specifications
For more information, contact Miovision to request the Connect data sheet.
Operating temperatures
● Operating: -40C to +80C
● Absolute maximum: -40C to +85C
148 Manitou Drive, Suite 101, Kitchener, ON, N2C 1L3 • 1.877.646.8476 •​ ​miovision.com
Physical specifications
All dimensions in millimeters unless otherwise specified.
148 Manitou Drive, Suite 101, Kitchener, ON, N2C 1L3 • 1.877.646.8476 •​ ​miovision.com
United States and Canada Regulatory Statements
This device complies with Industry Canada’s licence-exempt RSSs. Operation is
subject to the following two conditions:
(1) This device may not cause interference; and (2) This device must accept any
interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux
appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions
suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de
l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d'en compromettre le fonctionnement.
CAN ICES-3 (B)/NMB-3(B) – This Class B Digital Apparatus Complies with Canadian
ICES-003.
Cet Appareil numerique de la classe (B) est conforme a la norme NMB-003 du Canada.
Note: This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
148 Manitou Drive, Suite 101, Kitchener, ON, N2C 1L3 • 1.877.646.8476 •​ ​miovision.com
N’approuve aucune modification apportée à l’appareil par l’utilisateur, quelle qu’en soit
la nature. Tout changement ou modification peuvent annuler le droit d’utilisation de
l’appareil par l’utilisateur.
Warning: RF Exposure Compliance
The antenna(s) used for this transmitter must be installed to provide a separation
distance of at least 20 cm from all persons and must not be co-located or operating in
conjunction with any other antenna or transmitter. Users and installers must be
provided with antenna installation instructions and transmitter operating conditions for
satisfying RF exposure compliance.
148 Manitou Drive, Suite 101, Kitchener, ON, N2C 1L3 • 1.877.646.8476 •​ ​miovision.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Create Date                     : 2016:10:25 13:53:44-04:00
Modify Date                     : 2016:10:25 15:27:04-04:00
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Producer                        : Skia/PDF m55
Metadata Date                   : 2016:10:25 15:27:04-04:00
Document ID                     : uuid:31ebb03e-bc6b-4cce-8243-73940039b7d6
Instance ID                     : uuid:31b9ebe4-8f1e-4495-be42-66e1e153639b
Format                          : application/pdf
Page Count                      : 6
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AJX2-SKN

Navigation menu