User’s Manual
No.99MAL108B5
U-WAVE-T
Introduction
Precautions for Dust and Water Resistance
The U-WAVE-T is a wireless communication tool for transmitting measurement data to the Mitutoyo
U-WAVE-R (option) by connecting to a Digimatic-output interfaced tool with the supplied connecting
cable. The U-WAVE-T is also categorized into two types: IP67 type and buzzer type. To obtain the
highest performance and the longest service life from the U-WAVE-T, carefully read this User’s Manual
thoroughly prior to use. After reading this manual, keep it near the U-WAVE-T for quick reference. The
specifications of the U-WAVE-T and descriptions in this manual are subject to change without prior
notification.
Safety Precautions
Use the U-WAVE-T in conformance with the specifications, functions and precautions for use given in this
manual. If the U-WAVE-T is used in other way, it may jeopardize safety.
• Do not use the U-WAVE-T near a medical device that has a possibility of causing a
malfunction due to radio waves.
• The U-WAVE-T using an electric wave has a possibility that communication is interrupted
WARNING under the influence of external noises, etc., even within the distance of communication of the
electric wave. In this case take sufficient failure prevention action (security measures).
• In the event the U-WAVE-T should fail, take sufficient failure prevention action (security
measures).
• Do not disassemble, short, modify, or heat the supplied battery. The leaked contents may get
into your eyes. Also, heat generation or explosion may result.
• The battery used in the U-WAVE-T contains an irritating substance.
Should this liquid substance be applied to your eyes or skin by accident, immediately rinse it
away in clean water.
• Should the battery be swallowed by accident, immediately rinse the mouth out and induce
vomiting the battery while drinking a large amount of water. After then consult a doctor.
!
Notes on Export Regulations
!
WARNING
The U-WAVE-T falls into the Catch-All-Controlled Goods or Program under the Category 16 of
the Separate Table 1 of the Export Trade Control Order or the Category 16 of the Separate
Table of the Foreign Exchange Control Order, based on the Foreign Exchange and Foreign
Trade Law of Japan.
Further, this User's Manual also falls into the Catch-All-Controlled Technology for use of the
Catch-All-Controlled Goods or Program, under the Category 16 of the Separate Table of the
Foreign Exchange Control Order.
If you intend re-exporting or re-providing the product or technology to any party other than
yourself, please consult with Mitutoyo prior to such re-exporting or re-providing.
Precautions for the Wireless Law
The U-WAVE-T can use in Japan, EU member countries, U.S.A, Canada .
The U-WAVE-T cannot be used in countries other than Japan, EU member countries, U.S.A, Canada
・ The U-WAVE-T must follow the corresponding regulation which is specified in the country
to use an electric wave.
WARNING • Do not disassemble or modify any part of the U-WAVE-T.
• Do not peel off the certification label stuck on the U-WAVE-T.
The use of any U-WAVE-T without the label is prohibited.
• Remove the battery before taking an airplane and do not use the U-WAVE-T
in the airplane. The use of a wireless equipment in the airplane is prohibited.
!
This device complies with Part 15 of the FCC Rules and RSS-Gen of IC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause
undesired operation.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la class B est conforme à la norme NMB-003 du Canada.
Changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
Notes
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications, However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
-- Consult the dealer or an experienced radio/TV technician for help.
Precautions on Wireless Communication Environments
Notice that performance of the U-WAVE-T may not be fully delivered depending on the environment
such as a midway obstruction.
For the items of obstruction factors refer to the following table.
1) The U-WAVE-T may not be able to communicate in the case.
Item
Description
Concrete wall
Disables communication if the U-WAVE-T is completely enclosed
with a concrete wall.
Metallic partition, etc.
Have the possibility of reducing the communication speed or
blocking communication.
Wireless LAN, Bluetooth
ZigBee, microwave oven,
and other communication
devices
Have the possibility of reducing the communication speed or
blocking communication. Separate the communication channel
(band ID) and installation site of each device as far as possible
from those of the U-WAVE-T.
Machine tools, etc.
In the worksite operated with machine tools such as electrical
discharge Machines, crane for transfer, arc welding etc.,
have the possibility of reducing the communication speed or
blocking communication.
To obtain the highest performance from the IP67 type U-WAVE-T, be sure to observe the following
precautions.
IMPORTANT
• The dust and water resistance of the U-WAVE-T is assured under the condition where the connecting
cable is connected and the battery cover is mounted.
If the U-WAVE-T is not used for an extended period, store it with each cover mounted to prevent from
water and oil.
• To deliver the maximum performance of protection against water and dust (IP67), mount the battery
cover tightly with screws after setting the battery. Also, do not remove the packing from the cover.
• If the connecting cable sheath is broken, a liquid will infiltrate into the U-WAVE-T and a Measuring
tool due to capillary phenomenon, resulting in trouble. Immediately replace the cable.
• Use the U-WAVE-T with sufficient care so that the packing on each part may not be damaged with
cutting chips, dirt, etc. Should any packing be damaged, the dust and water resistance will be
impaired. Immediately replace the packing or have the U-WAVE-T repaired by a service center.
• Rubber and other materials used for rubber caps and sealing portions are not fully effective for
diversified coolants, chemicals, etc. If these materials become deteriorated markedly, consult the
nearest Mitutoyo sales office.
• The U-WAVE-T is provided with such a structure that cannot be disassembled by applying seals to
individual parts.
If any sealed part is disassembled, then a predetermined performance will not be delivered.
• Do not use the U-WAVE-T at sites which might be submerged. The U-WAVE-T cannot prevent liquids
such as a coolant from infiltrating.
TIP
IP67 protection level (For details refer to IEC 60529.)
• Protection against foreign matters (Level 6): Protects an object against the ingress of dust and dirt,
and against a full contact with it.
• Protection against water (Level 7): No causing harmful effects when submerged in water for 30
minutes with its bottom end at a depth of 1 m below the surface of water.
Other Precautions
The following deeds and situations will cause a failure or malfunction in the U-WAVE-T.
Care should be exercised.
IMPORTANT
• Do not give a sudden shock such as a drop or apply an excessive force to the U-WAVE-T.
• If the U-WAVE-T is not used more than 3 months, remove the battery from the U-WAVE-T and store it
in a safe place. Otherwise, leaks from the battery may damage the U-WAVE-T.
• Avoid using or storing the U-WAVE-T at sites which are exposed to direct sunlight, excessively high
or low temperature.
• Avoid using or storing the U-WAVE-T at sites where it may be subject to the adhesion of solution
such as acid and alkali or organic solvent.
• If a high-voltage device such as an electro-spark engraving pen is used for the U-WAVE-T, the
internal electronic parts may be damaged.
• Exercise care so as not to apply an undue force or curvature to the connecting cable.
• If the battery voltage has come down, replace the battery ahead of time before the operation
becomes unstable.
Warranty
In the event that the U-WAVE-T should prove defective in workmanship or material, within one year
from the date of original purchase for use, it will be repaired or replaced, at our option, free of charge
upon its prepaid return to us.
This warranty is effective only where the U-WAVE-T is properly installed and operated in conformance
with the instructions in this manual.
Disposal of Old Electrical & Electronic Equipment (Applicable in the European Union
and other European countries with separate collection systems)
This symbol on the U-WAVE-T or on its packaging indicates that the U-WAVE-T shall not be treated
as household waste. To reduce the environmental impact of WEEE (Waste Electrical and Electronic
Equipment) and minimize the volume of WEEE entering landfills, please reuse and recycle.
For further information, please contact your local dealer or distributors.
[1] Name of Each Part and External Dimensions (Unit : mm)
1. LED display (green, red, orange) 2. Battery cover
4. Device ID label
5. Buzzer holes (for the buzzer type only)
3. Connector cover
6. Certification label
4. Device ID label
3. Connector cover
2. Battery cover
6. Buzzer holes
(for the Buzzer type)
1. LED display
5. Certification label
(This label is different according to the type.)
[2] Replacing the Battery
1) Setting the battery
No battery has been set before shipping. After unpacking the U-WAVE-T, set the battery with the
following procedure. When screwing or unscrewing the screws, always use the size 0 screwdriver (No.
05CZA619) of the standard accessory and tighten or loosen them with a torque of 5 to 8 N•cm.
(1) Remove the two mounting screws (M2.5X0.45X3/No. A115-2515C) with the size 0 screwdriver.
(2) Dismount the battery cover.
(3) Orientate the battery plus side toward the cover, slide its one end into the “+” terminal on the
U-WAVE-T, and then insert the other end into the battery retaining claw.
(4) Check that the packing (No. 02AZD734) has been attached correctly to the specified position.
(5) Mount the battery cover.
(6) Tighten the mounting screws with the size 0 screwdriver to fix the cover.
(7) Make sure that no part of the packing is detached.
(1),(6)
(3)
2) The U-WAVE-T may influence on the peripheral equipment in the case
Item
Description
Medical device
Do not use the U-WAVE-T near a medical device such as a laser
surgical knife and a bathroom scale.
2) Removing the battery
To remove the battery, use a small flat-blade screwdriver, etc. Insert the screwdriver between the
battery retaining claw and the battery, and then remove the battery by using the screwdriver as
leverage.
3) Low battery alarm
[7] Specifications
If the battery voltage becomes considerably low, the LED display blinks red and the U-WAVE-T sends
a low battery alarm error to the U-WAVE-R. Immediately replace the battery.
(The buzzer type alarms a low battery voltage with a buzzer sound along with a blinking LED.)
In addition, the battery (CR2032) used as the power supply for the U-WAVE-T has such a property that
the battery voltage is abruptly restored in a period when the battery has been exhausted, if
measurement data is consecutively transmitted at intervals of several seconds. In such cases,
although low battery alarm errors are not output, the LED display becomes dark and the buzzer sound
becomes small gradually. In such cases, replace the battery immediately.
IMPORTANT
• Always use the CR2032 battery (lithium battery).
[3] Connect the Connecting cable to U-WAVE-T
• After loaded with the battery, connect the connecting cable (option, details see section 8)
IMPORTANT
When installing the U-WAVE-T using the connecting cable (02AZD790A, B), particularly
pay attention to the cable orientation. If the cable is connected in the reverse orientation,
data cannot be transmitted.
Black-marked side => U-WAVE-T
Gray-marked side
=> Measuring tool
Black
U-WAVE-T side
Measuring tool side
(The connector shape and color differs depending on the
Measuring tool to be used. )
• Set up the connecting cable with the following procedure.
When screwing or unscrewing the screws, always use the size 0 screwdriver of the
standard accessory and tighten or loosen them with a torque of 5 to 8 N•cm.
(1) Remove the two mounting screws (M1.7X0.35X2.5/No.A115-1712C) of the connector cover with
the size 0 screwdriver.
(2) Dismount the connector cover.
(3) Check that the packing (No. 09GAA374) has been attached correctly to the specified position.
(4) Connect the connecting cable with the U-WAVE-T.
(5) While pressing the connecting cable end with fingers, tighten the cable fixing screws so that no gap
appears between the cable connector and the U-WAVE-T.
(6) Make sure that no part of the packing is detached.
(1)
IP67 type
02AZD730D
02AZD880D
005WWCA0166(Japan)
005WWCA0168(Japan)
Certification number
Do not connect the connecting cable forcibly in a state that the packing (No. 09GAA374) is not in the
correct position on the U-WAVE-T body. Otherwise, the packing may be damaged so that a failure
may be caused.
After loaded with the battery and connected to a connecting cable, the U-WAVE-T needs to register the
setting information of U-WAVE-R.
Please read the “U-WAVEPAK User’s Manual“ in “PDF_Manual” folder of the CD supplied as a standard
accessory of U-WAVE-R for a detailed registering method and content.
“Adobe Reader” of Adobe Systems INC. is necessary to read.
IP67
Without
With
• “Registering the setting information” should be performed by DATA switch of the connecting
cable before connecting to the Measuring tool.
• The registered information is stored after changing battery.
[5] Connecting to Measuring tool
A Conformity standard
Wireless communication protocol
Communication frequency
Used band
Modulation method
Wireless communication speed
LED display
Battery
Battery life
Operating temperature (humidity)
Storage temperature (humidity)
External dimensions
U-WAVE-T mass
[8] Connecting Cables
As for connecting cables, it is necessary to select a cable compatible with a Measuring tool to be used.
Use an appropriate connecting cable from among those in the following table.
Parts No. Model
02AZD790A
Water-resistant type
with data out switch type
02AZD790B
Water-resistant type with
data out switch type
02AZD790C
With data out switch type
02AZD790D
10 pins type
• Exercise great caution about the cable routing,
Cable may be disconnected from the instrument or connection part may be damaged
if the excessive force is applied when the cable is snagged to the workpiece, etc..
• Tighten the connecting cable (02AZD790A, B, G) to the Measuring tool with the screw surely.
t ≤ 2sec
None
Transmits the Cancel command.
2 sec < t ≤ 5 sec
Orange blinking 0.1 sec interval
Executes U-WAVE-R search.
5 sec < t ≤ 10 sec
Orange blinking 0.3 sec interval
02AZD790E
6 pins type
NOTE
• The Cancel command is a command to inform a U-WAVE-R of data error when wrong measurement
data is transmitted to the U-WAVE-R due to an operating error. However, the wrong measurement data
is not canceled by the command. It is to inform that the previous data is different from measuring value.
• When the U-WAVE-R search is executed, U-WAVE-T is connected with U-WAVE-R that
can be registered.
• If the DATA switch is held down for more than 10 seconds, the orange LED stops blinking and nothing
will function.
02AZD790F
A flat form straight type
The U-WAVE-T can check whether to have performed normal communication with a U-WAVE-R
by a specific LED display (and buzzer sound).
However, buzzer sounds are available only for the buzzer type U-WAVE-T.
Description of state
LED
Buzzer sound
Wireless communication has been properly completed.
Green LED blinking
Short 2 times
Red LED blinking
Long 1 time
2) Initializing the setting information
If communication is disabled while using the U-WAVE-T, first refer to Troubleshooting
In U-WAVE-R User’s Manual, if communication is still disabled, initialize the setting information
registered in section 4 to default settings, and then retry communication.
Initialize the setting information with the following procedure.
(1) Remove the battery being loaded. For information about how to remove the battery, refer to section 2.
(2) While holding down the DATA switch on the connecting cable connector, reload the battery in
place. The setting information is initialized.
(3) Remount the battery cover, and set up the U-WAVE-T.
IEEE802.15.4 compatible
2.405 to 2.475 GHz
15 channels (at intervals of 5 MHz)
DSSS (Direct Sequence Spread Spectrum)
250 Kbps
Green/orange/red: 3 discrete color display
CR2032 (3V): 1 piece
400,000 times
0 to 40°C (20 to 80%RH, with no condensation)
-10 to 60°C (20 to 80%RH, with no condensation)
44 X 29.6 X 18.5 (mm)
Approx. 23 g
・User’s manual (this manual) No. 99MAL108B
・Precaution for the battery No.99MAL111W
・Size 0 screwdriver No. 05CZA619 ・Lithium battery
・ CR2032C(B)N
・Warranty card
○ Optional accessories
No. 02AZD790A to G: Connecting cables (For details see section 8.)
IMPORTANT
The U-WAVE-T performs data communication with DATA switch as shown below.
Operations
DATA switch push-down time t
LED
Approx. 20 m (line-of-sight distance under office environments)
Japan
ARIB STD-T66
Europe EN 50371:2002
EN 300 440-1 V1.3.1 and EN 300 440-2 V1.1.2
EN 301 489-01 V1.6.1 and EN 301 489-03 V1.4.1
U.S.A ・47 CFR Part 15.247:(Subpart :C)
・47 CFR Part 15,(Subpart :B)
Canada・RSS-210 (Issue 7) and RSS-Gen (Issue 2)
・ICES 003 (Issue 4)
○ Standard accessories
• After registering the setting information, connect the U-WAVE-T to the Measuring tool.
• Clamp the cable leading to a Measuring tool using the supplied cable clamp or a Velcro fastener so
that measurement is not interfered and the LED display of the U-WAVE-T can be easily viewed.
[6] Functions
1) Data communication
Less than 1 mW (0 dBm)
Distance of communication
IMPORTANT
• Wireless communication has failed.
• An error has occurred.
VXU-02AZD880D (U.S.A)
4396B-02AZD880D (Canada)
Protection class
[4] Register the setting information of U-WAVE-R
Transmits measurement data.
VXU-02AZD730D (U.S.A)
With/without buzzer
(5)
IMPORTANT
Buzzer type
4396B-02AZD730D (Canada)
Transmission output
• The battery supplied at the time of purchase is to check the functions and performance of the
U-WAVE-T. The predetermined length of life may not be met.
• Even for the used CR2032 battery, its voltage may recover in a short time after it is removed from
the U-WAVE-T. However, do not continue to use the old battery. Be sure to replace the battery
with a new one.
• Upon disposal of the battery comply with the related ordinance, regulation, etc.
• When removing or setting the battery, exercises care so as not to break or bend the battery terminal
by applying an undue force to it. Especially, if a broken piece of the battery terminal should enter
the U-WAVE-T, a failure may be caused.
DATA switch
Model
Code No.
Series No,
Product Name
500
500
571
572
573
ABS Coolant Proof
Super Caliper
ABS Coolant Proof
ABS Coolant Proof
ABS Coolant Proof
293
293
--329
350
--468
Coolant Proof Micrometer
MDC-MJ/MJT
Coolant Proof Micrometer
MDE-MJ
Coolant Proof Exclusive Micrometer
(The end of the mark is –MJ)
Depth Micrometer
DMC-M
Coolant Proof Digimatic Micrometer Heads
MHN-M/MJ/MJN
Digimatic Exclusive Micrometer
(The end of the mark is –M/PM)
Digimatic Holtest
HTD-R
500
571
572
500
---
ABS Digimatic Caliper
ABS Digimatic Depth Gage
ABS Digimatic Scale Units
ABS Digimatic Caliper
ABS Digimatic Exclusive Caliper
178
179
515
518
519
542
543
544
544
192
500
511
543
543
550
551
552
570
547
572
574
575
811
Surftest
SJ-201/301/401/402
Digi-Derm
DGE
CERA Height Master
HMD-C
QM-Height
QMH-S
Digital Mu-Checker
Display Unit
EB/EC-D
Digimatic Indicator
ID-H/ID-F
Laser Scan Micrometer
LSM-9506
Laser Scan Micrometer
LSM-6200/6900
(It applies when using Digimatic Codeout unit.(02AGC840))
Difference/Sum Unit
SD-U1
Heightmatic
HDF
Digimatic Micrometer Heads
MHD-M
Digimatic Micrometer Heads
CLM-MH
Soft-Touch Micrometer
CLM
Quickmike
MDQ
Exclusive Quickmike
(The end of the mark is –QM)
Digimatic Micrometer
MDC-M
Digimatic Exclusive Micrometer
(The end of the mark is -DM)
Digimatic Tubular Inside Micrometer
IMJ-M
Digimatic Tubular Inside Micrometer
IMZ-M
Digimatic Holtest
HTD
Digital Height Master
HME-DM
ABS Borematic
SBM-C
Hardness Testing Machine
HM-100/200/HV-100/HH-411
Rockwell Type Hardness Testing Machines
HR-500
Digimatic Height Gage
HDM-A/HD-A
Digimatic Caliper
CD
ABS Digimatic Bore Gage
CG-D
ABS Digimatic Indicator
ID-S
ABS Digimatic Indicator
ID-C
Digimatic Caliper
CD
Digimatic Caliper
CD
Digimatic Carbon Fiber Caliper
CFC
ABS Digimatic Height Gage
HDS-HC/C
ABS Digimatic Depth Gage
ABS Digimatic Scale Units
SD-E/SDV-E/SD-V/SDV-F
Heightmatic
HDF-N
ABS Digimatic Indicator
ID-U
Hardness Testing Units
HH-300
543
ABS Digimatic Indicator
572
574
164
227
227
293
--293
--339
337
468
515
568
810
810
Caliper
Depth Gage
Digimatic Scale Units
Exclusive Caliper
CD-PMX/PM/GM
CD-SPM
VDS-PMX
SD-G
NTD-PMX/PM
CD-CX/C
VDS-/DCX/DC
SD-D/SDV-D
CD-SC
(The end of the mark is –CX/C)
02AZD790G
Water-resistant type with
flat form straight type
ID-N/ID-B
Mitutoyo Corporation
20-1, Sakado 1-Chome, Takatsu-ku, Kawasaki-shi, Kanagawa 213-8533, Japan
IMPORTANT
Once initialization is performed, the setting information used until then is all cleared.
KAWASAKI, JAPAN

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Create Date                     : 2010:02:16 13:25:26+09:00
Modify Date                     : 2010:02:16 13:25:26+09:00
Producer                        : Hyf_PdfCreatorMP 2.1.4(Windows Driver)
Page Count                      : 2
EXIF Metadata provided by EXIF.tools
FCC ID Filing: VXU-02AZD730D

Navigation menu