Mitutoyo 02AZD810C U-WAVE-R User Manual Revised

Mitutoyo Corporation U-WAVE-R Users Manual Revised

Users Manual Revised

Download: Mitutoyo 02AZD810C U-WAVE-R User Manual Revised
Mirror Download [FCC.gov]Mitutoyo 02AZD810C U-WAVE-R User Manual Revised
Document ID947512
Application IDRhOjq/AQzSPvZE5NA9hREw==
Document DescriptionUsers Manual Revised
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize22.94kB (286803 bits)
Date Submitted2008-05-27 00:00:00
Date Available2008-05-28 00:00:00
Creation Date2008-05-16 14:18:33
Producing SoftwareAcrobat Distiller 7.0.5 (Windows)
Document Lastmod2008-05-16 14:19:49
Document TitleMicrosoft Word - 取説原稿_U-WAVE-R_FCC版英文_20080516.doc
Document CreatorPScript5.dll Version 5.2
Document Author: U841030

02AZD810C User Manual
Product
Model
FCC ID
IC
U-WAVE-R
02AZD810C
VXU-02AZD810C
4396B-02AZD810C
U-WAVE-R
Introduction
The U-WAVE-R in conjunction with a Mitutoyo U-WAVE-T (available separately) allows
wireless communication of the measurement data from Digimatic-output interfaced tool to load
it to a personal computer for data display.
To obtain the highest performance and the longest service life from the U-WAVE-R, carefully
read this User’s Manual thoroughly prior to use.
After reading this manual, keep it near the U-WAVE-R for quick reference.
The specifications of the U-WAVE-R and descriptions in this manual are subject to change
without prior notification.
Safety Precautions
Use the U-WAVE-R in conformance with the specifications, functions and precautions for use
given in this manual. If the U-WAVE-R is used in other way, it may jeopardize safety.
!
WARNING
• Do not use the U-WAVE-R near a medical device that has a possibility of causing a
malfunction due to radio waves.
• The U-WAVE-R using an electric wave has a possibility that communication is
interrupted under the influence of external noises, etc., even within the distance of
communication of the electric wave. In this case take sufficient failure prevention
action (security measures).
• In the event the U-WAVE-R should fail, take sufficient failure prevention action
(security measures).
Notes on Export Regulation
!
WARNING
The U-WAVE-R falls into the Catch-All-Controlled Goods or Program under the
Category 16 of the Separate Table 1 of the Export Trade Control Order or the
Category 16 of the Separate Table of the Foreign Exchange Control Order,
based on the Foreign Exchange and Foreign Trade Law of Japan.
Further, this User's Manual and U-WAVE Quick Manual (No. 99MAL110B) also
falls into the Catch-All-Controlled Technology for use of the Catch-All-Controlled
Goods or Program, under the Category 16 of the Separate Table of the Foreign
Exchange Control Order.
If you intend re-exporting or re-providing the product or technology to any party
other than yourself, please consult with Mitutoyo prior to such re-exporting
or re-providing.
User’s Manual
No.99MAL109B2
Precautions for Use
The following deeds and situations will cause a failure or malfunction in the U-WAVE-R.
Care should be exercised.
IMPORTANT
• The U-WAVE-R operates on the power supply from a personal computer. A personal
computer may generate large noises depending on the manufacturer and model. Be sure to
verify the whole system operation once prior to use.
• Do not give a sudden shock such as a drop or apply an excessive force to the U-WAVE-R.
• If the U-WAVE-R is not used more than 3 months, disconnect the U-WAVE-R from the
personal computer and store it in a safe place.
• Avoid using or storing the U-WAVE-R at sites which are exposed to direct sunlight,
excessively high or low temperature.
• Avoid using or storing the U-WAVE-R at sites where it may be subject to the adhesion of
solution such as acid and alkali or organic solvent.
• If a high-voltage device such as an electro-spark engraving pen is used for the U-WAVE-R,
the internal electronic parts may be damaged.
• Exercise care so as not to apply an undue force or curvature to the USB cable.
Warranty
In the event that the U-WAVE-R should prove defective in workmanship or material, within
one year from the date of original purchase for use, it will be repaired or replaced, at our
option, free of charge upon its prepaid return to us.
This warranty is effective only where the U-WAVE-R is properly installed and operated in
conformance with the instructions in this manual.
Disposal of Old Electrical & Electronic Equipment (Applicable in the European
Union and other European countries with separate collection systems)
This symbol on the U-WAVE-R or on its packaging indicates that the U-WAVE-R shall
not be treated as household waste. To reduce the environmental impact of WEEE
(Waste Electrical and Electronic Equipment) and minimize the volume of WEEE
entering landfills, please reuse and recycle.
For further information, please contact your local dealer or distributors.
[1] Name of Each Part and External Dimensions (Unit : mm)
Precautions for the Wireless Law
The country (region) that can use The U-WAVE-R by the code No. and certification number is
different. Please confirm U-WAVE-R must be in the country (region) that uses it in the table
below before it uses it.
Use excluding the country (region) specified by the certification number is prohibited by the law.
Country
Japan , EU
U.S.A , Canada
Code No.
02AZD810A
02AZD810C
VXU-02AZD810C (U.S.A)
005WWCA0038 (Japan)
Certification number
4396B-02AZD810C (Canada)
!
WARNING
1. POWER (Green LED)
4. INIT. Switch (Initialize switch)
2. ERROR (Red LED)
5. Device ID label
3. USB connector
6. Certification label
6. Certification label
(This label is different according
to the country (region).)
4. INIT. switch
• The U-WAVE-R must follow the corresponding regulation which is specified in the
country to use an electric wave.
• The U-WAVE-R for Japan and Europe (02AZD810A) cannot be used in countries
other than Japan and Europe.
• The U-WAVE-R for U.S.A and Canada (02AZD810C) cannot be used in countries
other than U.S.A and Canada.
• Do not disassemble or modify any part of the U-WAVE-R.
• Do not peel off the following certification label stuck on the U-WAVE-R.
The use of any U-WAVE-R without the label is prohibited.
• Do not use the U-WAVE-R in an airplane.
The use of a wireless equipment in the airplane is prohibited.
Precaution for 02AZD810C (U.S.A and Canada type)
Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
Notes
5. Device ID label
3. USB connector
1. POWER
(Green LED)
2. ERROR
(Red LED)
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
[2] Software Installation
provide reasonable protection against harmful interference in a residential installation.
The U-WAVE-R outputs measurement data to a personal computer using the dedicated
This equipment generates, uses and can radiate radio frequency energy and, if not
software “U-WAVEPAK” included in the CD supplied as a standard accessory.
installed and used in accordance with the instructions, may cause harmful interference
Before using the U-WAVE-R be sure to read the standard accessory
to radio communications, However, there is no guarantee that interference will not
“U-WAVE QUICK Manual” thoroughly, and then install the “U-WAVEPAK” and “USB Driver”.
occur in a particular installation. If this equipment does cause harmful interference to
IMPORTANT
radio or television reception, which can be determined by turning the equipment off
• Log in to Windows by ‘Administrator’.
and on, the user is encouraged to try to correct the interference by one or more of
• Be sure to install the U-WAVEPAK before connecting the U-WAVE-R to a personal computer.
the following measures:
• When connecting the U-WAVE-R to a USB Hub, always use a self-powered USB Hub.
-- Increase the separation between the equipment and receiver.
• The U-WAVE-R does not support the operation in the Standby or Hibernate of a personal
computer. Cancel each setting in the U-WAVE-R prior to use.
Precautions on Wireless Communication Environments
• Please read the “U-WAVEPAK User’s Manual“ in “PDF_Manual” folder of the CD supplied as a
Notice that this performance of the U-WAVE-R may not be fully delivered depending on the
standard accessory for a detailed operation method of U-WAVEPAK.
environment such as a midway obstruction.
“Adobe Reader” of Adobe Systems INC. is necessary to read.
For the items of obstruction factors refer to the following table.
Item
Description
[3] Setup
Disables communication if the U-WAVE-R is completely
1) Setting the communication information
Concrete wall
enclosed with a concrete wall.
You need to set various information necessary for communication in the U-WAVE-R using
Have the possibility of reducing the communication speed
the U-WAVEPAK. (No information is registered default setting.)
Metallic partition, etc.
or blocking communication.
The information required to be set is as shown in the following table.
Item name
Description
Wireless LAN, Bluetooth,
Have the possibility of reducing the communication speed
ZigBee, microwave oven,
or blocking communication. Separate the communication
ID for grouping the U-WAVE-T and the U-WAVE-R.
and other communication
channel (band ID) and installation site of each device as far
Group ID
Communication is possible between the U-WAVE-T and the U-WAVE-R
devices
as possible from those of the U-WAVE-R.
which have the same ID.
Band ID
Number of a radio band to be used
Do not use the U-WAVE-R near a medical device such as a
Medical device
laser surgical knife and a bathroom scale.
The data transmitted from the U-WAVE-T to the U-WAVE-R includes a value
that is incremented by one each time communication is implemented.
Lack of data
The U-WAVE-R monitors this value and has a function to notify the personal
monitoring
computer of a data missing error.
level
A lack of data monitoring level is a value for prescribing how frequently this
error is notified.
IMPORTANT
• Please read the “U-WAVE Quick manual “ and “U-WAVEPAK User’s Manual“ in “PDF_Manual”
folder of the CD supplied as a standard accessory for setting the communication information.
• The U-WAVE-R will not function properly if a U-WAVE-R with the same group ID and band
ID settings exists nearby. Be sure to set different information for each ID in the U-WAVE-R.
2) Confirmation of U-WAVE-T
2) Installation procedure
Data transmission always fails and the red LED lights up.
• Is the LCD of the Measuring tool put in the count display state?
Communication is not possible if the LCD on the connected Measuring tool is turned off or in
the data entry state. Put the Measuring tool LCD in the count display state.
• Has the battery voltage come down?
If the battery is consumed to a low voltage, the red LED is blinking and data transmission is
disabled.
Replace the battery with a new one.
• Is the U-WAVE-T installed correctly on the Measuring tool?
Recheck that the U-WAVE-T and the Measuring tool are properly mated using the supplied
connecting cable.
Also, when using the specific connecting cable (02AZD791A, B), be sure to mate the
black-marked side of the connecting cable with the U-WAVE-T.
• Figure of how to attach the plate to the U-WAVE-R • Is the device ID described in the label on the U-WAVE-T set in the connecting state on the
U-WAVEPAK?
(Attachable at one of three positions.)
Unless it is in the connecting state, communication is not implemented.
Referring to read the “U-WAVE Quick manual “ and “U-WAVEPAK User’s Manual“ in
“PDF_Manual” folder of the CD supplied as a standard accessory, set up the system
correctly.
Install the U-WAVE-R at a location with a good view and eliminate any obstacle between the
U-WAVE-R and the U-WAVE-T. If installing it on a wall, etc., use the installation board
(No. 02AZD815) from among the standard accessories. To install the U-WAVE-R on a wall,
observe the following procedure.
(1) Attach the mounting plate to the U-WAVE-R backside with cross-recessed head tapping
screws (nominal size 2.6 × 6 No. A131-6221CP 2pcs.) in the standard accessories.
Screw holes are provided on the U-WAVE-R backside so that the mounting plate can be
fixed at one of three positions. Attach the mounting plate at an appropriate position
where the U-WAVE-R is easily mounted.
(2) Install the U-WAVE-R on a wall at a desired location with the two screws.
When installing the U-WAVE-R, refer to the following figure. Carefully install the U-WAVE-R
so that it will not drop from the wall.
• Figure of the installation board(Unit : mm)
Holes for mounting on a wall (2 pieces)
28
0.1
ole
2-
3(h
3) Confirmation of Wireless Communication Environments
2-
6(
ho
le)
39
45 45
18
Holes for attaching to the U-WAVE-R (2 pieces)
[4] Functions
1) Communication Function
The U-WAVE-R displays the data received from the U-WAVE-T.
Observe the following procedure for output operation.
(1) Connect the U-WAVE-R to a personal computer with a USB cable.
(2) Boot the U-WAVEPAK.
(3) Please read the “U-WAVE Quick manual “ and “U-WAVEPAK User’s Manual“ in
“PDF_Manual” folder of the CD supplied as a standard accessory for setting correctly.
(4) Press the DATA switch on the connecting cable connected to the U-WAVE-T or the DATA
switch on a Measuring tool to transmit data.
(5) The U-WAVE-R displays the received data and wireless transmits the confirm signal to
the U-WAVE-T.
(6) U-WAVE-T receives the confirmation signal from U-WAVE-R, and can confirm the success
(or failure) with LED (Buzzer).
IMPORTANT
• Log in to Windows by ‘Power Users’ or above.
• The U-WAVE-PAK automatically transmits the measurement data to the active application
software (such as Microsoft Excel or Microsoft word). Before booting multiple application
software simultaneously, be sure to activate the application software that you want to use.
• U-WAVE-R receives the data from the U-WAVE-T and wireless transmits the confirmation
signal to the U-WAVE-T, even if U-WAVEPAK doesn't start .
Please confirm measurements are displayed in the application software that is before the
measurement begins that wants to be used.
2) Low power supply alarm
Red LED blinks when the voltage of the power supply from the personal computer decreases.
(Green LED is in the state of lighting.)
Please change to a new USB cable at such a state.
3) Initializing the setting information
If communication is disabled while using the U-WAVE-R, first refer to section 5.
If communication is still disabled, initialize the information set in section 3 to default settings,
and then retry setup.
Initialize the setting information with the following procedure.
(1) Close U-WAVEPAK activated on the personal computer, and then pull off the cable of the
U-WAVE-R from the USB cable on the computer.
(2) While holding down the INIT. switch on the U-WAVE-R, plug the cable from the U-WAVE-R
into the USB cable on the personal computer again. Wait for 3 seconds or more in this state.
The setting information is initialized. At this time check that the green LED is blinking.
(3) Implement the setup again.
IMPORTANT
Once initialization is performed, the setting information used until then is all cleared.
Data communication is not stabilized, causing an error frequently.
• Is the U-WAVE-R separated too far from the U-WAVE-T?
• Is there any obstacle between the U-WAVE-R and the U-WAVE-T?
First, bring these instruments close to each other, and then try communication between
them. If an obstacle such as a wall or a metallic partition exists between the U-WAVE-R and
U-WAVE-T, communication may be affected adversely.
Also, the communication condition may be improved by changing the U-WAVE-R location and
orientation.
• Is any microwave oven, wireless LAN, or Bluetooth used nearby?
A wireless communication device or electric household appliance using a frequency of 2.4
GHz, which is close to the frequency used in the U-WAVE-R, might be affected adversely.
Particularly, medical equipment could cause a threat to life due to electromagnetic
interference. Carefully use the U-WAVE-R while separating sufficiently from such
equipment.
Also, check the situation of used bands at the periphery with the U-WAVEPAK and change
the current band to that with better communication quality. It may be possible to stabilize
communication.
Make an attempt on this, referring to “U-WAVEPAK User’s Manual“ in “PDF_Manual” folder of
the CD supplied as a standard accessory.
[6] Specifications
1) U-WAVE-R for Japan and EU (02AZD810A)
Country
Code No.
Certification number
Transmission output
Distance of communication
A Conformity standard
Japan, Europe
02AZD810A
005WWCA0038 (Japan)
Less than 0 dBm (1 mW)
Approx.20 m(at line-of-sight distance under office environments)
Japan ARIB STD-T66
Europe EN 50371:2002
EN 300 440-1 V1.3.1 and EN 300 440-2 V1.1.2
EN 301 489-01 V1.6.1 and EN 301 489-03 V1.4.1
2) U-WAVE-R for U.S.A and Canada (02AZD810C)
Country
Code No.
Certification number
Transmission output
Distance of communication
A Conformity standard
U.S.A, Canada
02AZD810C
VXU-02AZD810C (U.S.A) / 4396B-02AZD810C (Canada)
Less than 0.5 mW (-3dBm)
Approx.14 m(at line-of-sight distance under office environments)
U.S.A ・47 CFR Part 15.247:(Subpart :C)
・47 CFR Part 15,(Subpart :B)
Canada ・RSS-210 (Issue 7) and RSS-Gen (Issue 2)
・ICES 003 (Issue 4)
3) Common Specifications
Item
Wireless communication protocol
Communication frequency
Used band
Modulation method
Wireless communication speed
LED display
Output to a personal computer
Power supply system
Operating temperature (humidity)
Storage temperature (humidity)
External dimensions
U-WAVE-R mass
Description
IEEE802.15.4 compatible
2.405 to 2.475 GHz
15 channels (at intervals of 5 MHz)
DSSS (Direct Sequence Spread Spectrum)
250 Kbps
Green/red
USB2.0 12 Mbps (equivalent to USB1.1)
USB bus power system
0 to 40°C (20 to 80%RH, with no condensation)
-10 to 60°C (20 to 80%RH, with no condensation)
140 × 80 × 31.6 (mm)
Approx. 130 g
[5] Troubleshooting
If any trouble is not corrected even when the following actions are taken, contact a Mitutoyo
service center.
Please read the final page of “U-WAVEPAK User’s Manual“ in “PDF_Manual” folder of
the CD supplied as a standard accessory about Mitutoyo service center.
1) Confirmation of U-WAVE-R
(1) The green LED will not light up (or start blinking).
• Is the power to the personal computer turned on?
• Is the USB cable connected between the U-WAVE-R and personal computer?
The U-WAVE-R is supplied with power from the personal computer, and thereby no power
will be supplied to the U-WAVE-R unless the personal computer is turned on. Check the
USB cable for proper connection.
• Is the USB driver installed?
(2) The red LED is blinking with the green LED being lit.
• Is any undue force applied to the USB cable?
Check the connecting condition of the USB cable. Also, the USB cable might be broken
internally. Check it out by using a new USB cable.
(3) The green LED and red LED keep blinking alternately.
• Has setup been completed?
Referring to the U-WAVEPAK User’s Manual, set up the system correctly.
• Does any U-WAVE-R with the same group ID and band ID exist near the U-WAVE-R?
Set different information for each ID in the U-WAVE-R.
4) Standard accessories
・ U-WAVE-R User’s Manual (this manual) No. 99MAL109B2
・ U-WAVE QUICK Manual No. 99MAL110B1
・ USB cable (1m) No. C177-008
・ An Installation board No. 02AZD815
・ Cross-recessed head tapping screws
nominal size 2.6 × 6 No. A131-6221CP 2pcs.
・U-WAVEPAK No.02ARB110 (The following contents bundle into the CD)
・ U-WAVEPAK Program
・ USB Device Driver
・ Data Collection Macro for U-WAVE
・ U-WAVEPAK User’s Manual (Japanese version) No. 02ARB114、99MAL216J
・ U-WAVEPAK User’s Manual (English version) No. 02ARB124、99MAL216A
・ Warranty card
Mitutoyo Corporation
20-1, Sakado 1-Chome, Takatsu-ku, Kawasaki-shi, Kanagawa 213-8533, Japan

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-702
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Create Date                     : 2008:05:16 14:18:33+09:00
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2008:05:16 14:19:49+09:00
Metadata Date                   : 2008:05:16 14:19:49+09:00
Format                          : application/pdf
Title                           : Microsoft Word - 取説原稿_U-WAVE-R_FCC版英文_20080516.doc
Creator                         : U841030
Document ID                     : uuid:c48b5f37-9a7d-4bcf-8943-3a54af4f6424
Instance ID                     : uuid:74d026b5-e3d5-4bd8-98d6-d4a9714a4edd
Page Count                      : 3
Author                          : U841030
EXIF Metadata provided by EXIF.tools
FCC ID Filing: VXU-02AZD810C

Navigation menu