Monday FR200NM The product is RF Card Reader and Controller User Manual

MONDAY The product is RF Card Reader and Controller

User Manual

Download: Monday FR200NM The product is RF Card Reader and Controller User Manual
Mirror Download [FCC.gov]Monday FR200NM The product is RF Card Reader and Controller User Manual
Document ID2753845
Application IDVyfInD5W4z+XEPLMaZtWjA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize36.17kB (452132 bits)
Date Submitted2015-09-18 00:00:00
Date Available2015-09-18 00:00:00
Creation Date2015-06-30 11:49:29
Producing SoftwareAdobe PDF Library 9.0
Document Lastmod2015-09-17 13:18:19
Document TitleUser Manual
Document CreatorWordìš© Acrobat PDFMaker 9.0
Document Author: user

RF Card Reader & Controller(Model: FR200series)
FR200 is equipment to be installed on a door frame or wall to control the access of the door by preregistered RF cards and passwords.
In a compact design with numbers and symbols displayed on the LCD screen by a touch sensor, it can be use
in various environments. It can be installed outside the room and house as the internal PCB is coated with
epoxy and used alone without connecting to additional devices as it has a built-in control circuit or in the
network environment after installing proprietary PC program.
Simple to register/delete/manage RF cards and passwords and easy to use by simply following the step-bystep instructions on the LCD screen and in voice guiding you to set up modes.
(Product Specification and Appearance)
Effective Distance(Mifare/EM Card)
: 4cm / 5cm (Based on ISO cards)
Storing capacity
: Up to 100,000 cards/passwords / 1,000,000 events
Unlock time
: 5 Seconds (Adjustable)
Door lock type
: Power Fail Safe or Power Fail Secure
Exit button
: Input of 1 exit button(Activating when low)
LCD/Audio guidance
: LCD / Built-in Speaker
Power(Excluding door lock)
: DC 12V, Power consumption: 150mA~350mA
Operating environments
: -20℃ ~ +65℃, 0~90% Absolute Humidity
Color / Size (WxHxD)/Weight
: Black / 73 x 126 x 18mm / 180g
(Wiring Diagram)
6 4
1 : BLACK
2 : RED
3 : WHITE
4 : GREEN
5 : YELLOW
6 : ORANGE
7 : BROWN
8 : BLUE
*. Power: Connect power GND to Pin 1 and +12V to Pin 2.
*. Relay Output: Connect Normal Open (Pin 7), Common (Pin 8) and Normal Close (Pin 5)
*. Sensors: Connect Sensor0 (Pin 4, Exit) and sensor1 (Pin 3, Door Status)
*. Signal Grounds: Connect to Pin 6 and Pin 1
Dead Bolt
VCC
GND
NO (Brown)
EM Lock
GND
VCC
COM (Blue)
NC (Yellow)
EXIT (Orange)
EXIT (Green)
GND (Black)
+12V (Red)
EXIT
Button
Above picture shows how to correctly press keys
(number and function buttons) on the keypad.
Power
12V DC
1/5
(How to use)
** Upon turning the product on, date screen (model name/date) will be displayed on LCD and, upon touching the front side
of the product, keypad with “number and function keys” are appeared. You can also set the keypad with “number and
function keys” to be always ON by following the function key operation sequence explained at 6.7 How to set the
backlight of LED/Keypad of this manual.
** All function settings including user registration, entrance/exit method, etc. can be started on “Management Menu” screen.
Each time you press F1 key in the “Management Menu”, screen will keep turning in order of “User Registration”, “User
Deletion”, “Change of User Information”, “User List” and “System Setting” and F2 key, in reverse order of the list..
** The description of each number/Function key is as follows:
-. # (hash): A key to confirm your selection (ENTER) in the course of the setting process.
-. F1: A key to turn the order of function screens upward.
-. F2: A key to turn the order of function screen downward, i.e reverse order of F1.
-. F3: A key to delete the last digit of the numbers entered in case you entered wrong numbers.
-. F4: A key to use to start, stop, cancel, exit function, etc. Press this key twice to go back to the initial date screen when
you want to set another function or finish a setting process.
** The recommended sequences for function setting and user registration.
1) Set functions and register user without registering an administrator.
2) After finishing both function setting and user registration, register administrators (up to 5) or change to
administrators in the “change of user information” screen.
3) Be sure to register administrators to prevent the set functions from being changed by an unauthorized person.
** Pay special attention to administrator’s cards or passwords not to be leaked
1. How to access administrator’s menu
1.1. In case an administrator is not registered
01.01
FR-200
12:34:56
-≫
Press F4
USER
1.USER
MANAGEMENT MENU
F1:UP
F2:DOWN
REGIST USER
#:ENTER
F4:EXIT
-≫
Press F1
LEVEL
2.ADMIN
-≫
1) Choose No. 2
-≫
Press #
ENTER USER ID
PRESENT CARD
F1: SKIP
-≫
2) Enter Administrator’s ID
REGIST USER
F1:SMGL
F4:MULTI
-≫
Press F1
-≫
3) Register CARD and Press #
ENTER PASSWORD
F1 : SKIP
-≫
4) Enter P/W and press #
and press #
REGIST COMPLETE
#:CONT. F4:STOP
Press F4 to finish registration of an administrator. If you want to register more administrators (Up to 5), press # and repeat
step 1) through 4) above
1.2. In case an administrator has already been registered
01.01
FR-200
12:34:56
-≫
Press F4
ENTER
ADMIN ID
-≫
2) Enter Administrator’s ID
PRESENT
CARD or PASSWORD
-≫
MANAGEMENT MENU
F1:UP
F2:DOWN
Enter P/W and press # or contact Administrator’s card
and press #
2. User Registration
2.1 Individual User
MANAGEMENT MENU
F1:UP
F2:DOWN
-≫
Press F1
ENTER USER ID
REGIST
#:ENTER
USER
F4:EXIT
-≫
Press #
-≫
2) Enter user ID and press #
PRESENT CARD
F1 : SKIP
REGIST USER
F1:SMGL
F4:MULTI
-≫
Press F1
-≫
3) Register a card and press #
ENTER PASSWORD
F1 : SKIP
4) Enter PW and press #
a user. If you want to register more users, press # and repeat step 1) through 4) above
2/5
USER LEVEL
1.USER 2.ADMIN
-≫
1) Choose No. 1
-≫
REGIST COMPLETE
#:CONT. F4:STOP
Press F4 to finish registration of
** You can register a user without entering a card or a password in User ID depending on the situation.
2.2. Multiple Users
MANAGEMENT MENU
F1:UP
F2:DOWN
REGIST
#:ENTER
-≫
Press F1
USER
F4:EXIT
REGIST USER
F1:SMGL
F4:MULTI
-≫
Press #
NUMBER OF CARD
-≫
Press F2
PRESENT CARD
2) Enter No. of cards to register
ENTER PASSWORD
F1 : SKIP
-≫
3) Register cards and press #
START USER ID
-≫
-≫
1) Enter start user ID and press #
-≫
4) Enter passwords and press # ,
REGIST COMPLETE
#:CONT. F4:STOP
and press #
** When a large number of users are registered, it will be easy to use if you register them with user ID in order.
** If you press # in Step 4) above, Step 3) will be displayed again for registering another card and then Step 4)
for entering password and it will repeat until you complete registering cards and entering passwords up to
the number entered in Step 2. After completing registration of the last user, press # to end the process.
** It is highly recommended that you prepare and manage the list of user ID’s and passwords of all registered
users separately for future use.
** You can fulfill all registration, management and deletion of user information in the PC in case the system
is networked with a PC.
3. Deletion of Users
3.1 Individual User
MANAGEMENT MENU
F1:UP
F2:DOWN
-≫
Press F1 twice
DELETE USER
#:ENTER
F4:EXIT
DELETE USER
F1:UP
F2:DOWN
-≫
Press #
ENTER USER ID
-≫
1) Enter ID to be deleted
-≫
Press F1
SINGLE
#:ENTER
USER
F4:EXIT
-≫
ALL USER
#:ENTER
F4:EXIT
-≫
Press #
DELETE COMPLETED
#:CONT. F4:STOP
press # to go to Step 1) to repeat deleting users and F4 to end the process
and press #
3.2 All Users
MANAGEMENT MENU
F1:UP
F2:DOWN
-≫
Press F1 twice
# : DELETE
ANY : CANCEL
DELETE USER
#:ENTER
F4:EXIT
DELETE USER
F1:UP
F2:DOWN
-≫
Press #
-≫
Press #
-≫
Press F1 twice (or F2 once)
Press #
DELETE COMPLETED
F1:UP
F2:DOWN
Indication all users have deleted. Press F4 twice to go to date screen
4. Change of User Information
MANAGEMENT MENU
-≫
F1:UP
F2:DOWN
Press F1 or F3 three times
CHANGE
#:ENTER
Press #
USER
F4:EXIT
CHANGE USER
F1:UP F2:DOWN
-≫
** On the “Change of User Information” screen, press F1 once to move to “Card Change” screen, twice to
“Security Level Change” screen and three times to “Password Change” screen.
4.1 Card Change
CARD
#:ENTER
F4:EXIT
-≫
Press #
ENTER USER ID
PRESENT
NEW CARD
-≫
Enter ID of card to be changed
-≫
Enter new card ID
EDIT COMPLETED
#:CONT. F4:STOP
Card has changed
and press #
4.2 Security Level Change
USER LEVEL
#:ENTER
F4:EXIT
Press #
-≫
ENTER USER ID
USER LEVEL
1.USER 2.ADMIN
-≫
Enter ID to be change and press #
Select security level
3/5
-≫
EDIT COMPLETED
#:CONT. F4:STOP
Press F4 to end the change
4.3 Password Change
PASSWORD
#:ENTER
F4:EXIT
Press #
ENTER USER ID
-≫
-≫
ENTER PASSWORD
EDIT COMPLETED
#:CONT. F4:STOP
-≫
Enter ID to be change and press # Enter new password and press #
Password has changed
5. User List
MANAGEMENT MENU
-≫
F1:UP
F2:DOWN
Press F1 4 times (or F2 twice)
VIEW
#:ENTER
Press #
1/100000
-≫
0000000002ABCDEF
Card information at ID No. 1
1/100000
Test User
User name at ID No. 1
F4:EXIT
-≫
-≫
6 Users
-≫
F1:UP
F2:DOWN
6 users in the list, Press F1
2/100000
User at ID No. 2
-≫
1/100000
-≫
User at ID No. 1. Press F1
2/100000
0000000002ABCDEG
Card information at ID No. 2
** 1/100000 indicates a user registered with ID No. 1/Number of total registered users. Each time F1 is
pressed, information of the next user will be appeared in order of ID number, card information and user name.
** User name will be displayed only when registered by a PC in the network environment.
** Press F2 to display the information of users in reverse order
6. System Setting
MANAGEMENT MENU
-≫
F1:UP
F2:DOWN
Press F1 5 times (or F2 once)
SYSTEM SETUP
#:ENTER
F4:EXIT
Press #
-≫
SYSTEM SETUP
F1:UP
F2:DOWN
Press F1 or F2 to set up the system.
** On the screen “System Setting F1: UP F2: DOWN”, each time you press F1, a screen for system setup will be displayed
in order of “Access Mode”, “Date/Time”, “Network Setup”, “Sound Volume”, “Door Open Time(Relay Time)”, “System
Reset”, “Network”, “LCD/Key Light”, “Selection Language”, “Case Open Alarm”. Press F2 to display them in reverse order.
6.1. Access Mode (Operation Mode)
ACCESS MODE
#:ENTER
F4:EXIT
ID / CARD
F1:UP
F2:DOWN
-≫
Press #
-≫
CARD
#:ENTER
F4:EXIT
-≫
ID + PASSWORD
#:ENTER
F4:EXIT
Each time you press F1, Access Mode will be changed
** Select one out of 3 combinations of ID, Card and Password depending on your requirements and press # to end
the setup
6.2. Date/Time
DATE & TIME
#:ENTER
F4:EXIT
Press #
-≫
YEAR:MON:DAY
-≫
20 :
Enter Year/Mon/Day and press #
HOUR:MIN:SEC
Enter hour/Min/Sec and press #
6.3. Network Setup
NETWORK SETUP
#:ENTER
F4:EXIT
Press #
NETWORK
1.VIEW
2.SETUP
Enter No. 1 to view Network Setting and No.2 to set up Network
-≫
6.3.1. Viewing Network Setting
FR-200 IP Address
192 . 168 . 0 . 100
PC IP Address
0.
0.
0.
-≫
-≫
SUBNET MASK
255 . 255 . 255.
PC
PORT
5000
-≫
GATEWAY
192 . 168 .
0.
-≫
FR-200 PORT
5000
-≫
MAC ADDRESS
-≫
0050 C200 0102
** Each time F1 is pressed, “Subnet Mask”, “Gateway IP”, “FR200 Port View”, “PC IP Address”, “PC Port Address”, “PC Port Number”,
and “MAC Address will be displayed. Press # to complete “Viewing Network Setting” and F4 to end the process
6.3.2. Network Setup
NETWORK MODE
1.SERVER 2.CLIENT
-≫
Select 1. Server
FR-200 PORT
5000
-≫
FR-200 IP ADDR
192 . 168 . 0 . 100
SUBNET MASK
-≫
-≫
255 . 255 . 255. 000
Enter IP Address and press # Enter Subnet Mask and press #
PC IP ADDRESS
192 .168 . 000 . 099
PC
-≫
PORT
5000
4/5
GATEWAY
-≫
192 . 168 . 000 . 001
Enter Gateway and press #
Enter Port No. and Press # Enter PC IP Address and Press #
Enter PC Port and press #
** In case FS300 program is being used, select Server Mode in Network Mode for easy connection with remote terminals
6.4. Sound Volume
SOUND VOLUME
#:ENTER
F4:EXIT
Press #
-≫
SOUND VOLUME
p : 10 n :
Enter number between 0~10. The larger, the bigger volume. Press # to end the setting
** It is preset at 10 before shipping from the factory.
** P (Present) means the current sound level and N (New) means the sound level at which you are going to set.
6.5. Door Open Time (Relay Time)
DOOR OPEN TIME
#:ENTER
F4:EXIT
-≫
Press #
DOOR OPEN TIME
C:0005
S:0000
Enter number between 0~4095. The larger, the longer relay time. Press # to end the setting
6.6. System Reset
SYSTEM RESET
#:ENTER
F4:EXIT
-≫
Press #
SYSTEM RESET
1.YES
2.NO
INITIALIZE
PLEASE WAIT
-≫
Press 1.
It takes a few minutes to reset the system
6.7. LCD/Key Light
LCD&KEY LIGHT
#:ENTER
F4:EXIT
-≫
Press #,
LCD&KEY ALWAYS
F1:UP
F2:DOWN
LCD ALWAYS ON
F1:UP
F2:DOWN
-≫
Press F1
-≫
Press F1
KEY ALWAYS ON
F1:UP
F2:DOWN
-≫
Select by pressing F1 or F4
** Each time F1 is pressed, the light status of LCD and Key is changed. Press # to end the setting
6.8. Language Selection
SELECT LANGUAGE
#:ENTER
F4:EXIT
Press #.
-≫
SELECT LANGUAGE
F1:UP
F2:DOWN
SELECT LANGUAGE
ENGLISH
-≫
-≫
SELECT LANGUAGE
KOREAN
Press F1 or F2 to choose a language (English or Korean). Press # to end the setting
6.9. Case Open Alarm
CASE OPEN ALARM
#:ENTER
F4:EXIT
-≫
Press #
CASE OPEN ALARM
1:ON 2:OFF 3:CLR
-≫
1) Enter No.1
ALARM SOUND OFF
1.AUTO 2.MANUAL
-≫
2) Enter No. 1
3) Alarm will activate when case is opened
SYSTEM SETUP
F1:UP
F2:DOWN
** When 1), 2) and 3) is selected, alarm will activate when case is opened but deactivate when the case is closed again.
** If No. 2 is selected in Step 2), you need to select No. 3 CLR in Step 1 to deactivate the alarm.
** If No. 2. OFF is selected in Step 1), alarm does not activate both when the case is opened or closed.
(Network Connection)
If you want to use FR200 under the network environment connected via Ethernet, you
are asked to order FR200N that is a Network Version integrated with a network module
shown on the left.
Proprietary PC program (Model name: FS300) is provided at free of charge as a
standard accessory to FR200.
BY the nature of the product, FR200 Series is a product recommended to use for a
simple access control purpose by installing it as a stand-alone device, where the high
level of security is not required. And FR200N Series is a network version of FR200
Series suitable for monitoring both access control and time & attendance on a realtime basis operated and controlled by a PC connected via Ethernet Communication.
5/5
FCC Notice
NOTE:
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
NOTE:
THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR
MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY
RESPONSIBLE FOR COMPLIANCE. SUCH MODIFICATIONS COULD VOID
THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION
IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY
NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST
ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE
THAT MAY CAUSE UNDESIRED OPERATION.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Tagged PDF                      : No
XMP Toolkit                     : 3.1-701
Modify Date                     : 2015:09:17 13:18:19+09:00
Create Date                     : 2015:06:30 11:49:29+09:00
Metadata Date                   : 2015:09:17 13:18:19+09:00
Creator Tool                    :  Word용 Acrobat PDFMaker 9.0
Document ID                     : uuid:07c5cf84-6974-4079-8d71-a9cd154ee9dc
Instance ID                     : uuid:0e204072-01d7-4ee3-a304-271a5e796ee9
Subject                         : 16
Format                          : application/pdf
Creator                         : user
Producer                        : Adobe PDF Library 9.0
Source Modified                 : D:20150630024859
Has XFA                         : No
Page Count                      : 6
Page Layout                     : OneColumn
Author                          : user
EXIF Metadata provided by EXIF.tools
FCC ID Filing: OD2-FR200NM

Navigation menu