Monessen Hearth Systems RFSC RCSITEL Transmitter User Manual MHNRTHC
Monessen Hearth Systems, Inc RCSITEL Transmitter MHNRTHC
User manual
Hand Held Full Function Remote for Signature Command System INSTALLATION AND OPERATING INSTRUCTIONS This remote control provides a safe, reliable and user-friendly remote control for the signature command system. The system can be manually or thermostatically turned on and off with the transmitter. Always check the appliance home owner’s manual for additional information, or warnings regarding accessory installation before using this remote control system. Carefully inspect the contents for shipping damage. If any parts are missing or damaged, immediately contact the dealer from whom you purchased the kit or Ambient Technologies Technical Support at 1 800 398 6195. Do not attempt to install any part of the kit unless all parts are in good condition. Please keep this booklet for future reference. CONTENTS OF KIT Description Transmitter Battery Alkaline AAA (for Transmitter) Instructions • • • • • • • • • • • Qty FEATURES/SPECIFICATIONS Thermostatic Control Battery Powered Low battery Indication Three Speed Control for Blower Three Level of Light Brightness adjustment Three Flame Height Settings Auxiliary On/Off Programmable Timer to turn blower on and off Child Proof Lock-out 16 Security Codes Reset Button WARNING Important Safety Information WARNING NOTE • Read this manual thoroughly prior to programming or operating any remote control. • This remote control system requires three (3) “AAA” alkaline batteries to power the transmitter. • This remote control system should only be used as described in this manual. Any other use is not recommended and will void the warranty. Due to the sensitive temperature monitoring components in the transmitter, it is necessary to allow the transmitter to stabilize to room temperature before accurate room temperatures are displayed. If the transmitter is activated from a severe cold condition, allow 15 minutes for accurate temperature readings to appear on the LCD display. Turn appliance OFF (at the appliance or remote receiver) if you are away from your house for an extended period of time. Never leave anything on top of the surface of the transmitter. Any modification of components will void the warranty and may cause a fire hazard. Installing Batteries INSTALLATIONS The remote transmitter uses three (3) “AAA” batteries. To install batteries, 1. Press down the battery door tab and pull out to remove the battery door. 2. Install the batteries as indicated on transmitter. 3. Close the battery door by snapping in place. 4. When three batteries are installed, the transmitter will initialize for 10 seconds and then is ready for use. 5. The batteries should be replaced at least once every 6 months or when the low battery icon indicator is displayed. Setting Privacy (DIP) Switch on Transmitter: The remote transmitter privacy (DIP) switches are preset at the factory. In the event of activation or interference from other nearby transmissions, reset the code using the following procedures: 1. Slide the code switches on the transmitter to your choice of ON or OFF position. Switches #1, #2, #3 and #4 are preset to “ON” for the transmitter. 2. On the Command Center, hold the OFF button while turning on the rocker switch (see figure). 3. Press ON button on the transmitter to learn. The receiver will give two beeps if the learning is successful; if not, repeat 2. 4. The transmitter is now ready to operate. Transmitter Dip Switch WARNING RFSC Hold OFF button while turning on the rocker switch of the Command Do not use two (2) or more remote control systems in the same area with the same dip switch settings, as they will communicate with each other. This may cause the appliances to malfunction. Reset Button: The reset button can be used to reset the transmitter if transmitter is not working properly. The reset button is located behind the battery door cover in the lower left corner of battery comparment. Using a paper clip, press the reset button and the transmitter will reset and initialize for 10 seconds before it can be used. General OPERATIONS The RFSC Remote Control has two (2) operating modes: Manual and Thermostatic. The control system can be set to temperature range between 45°F and 90°F. The blower speed and flame height can be adjusted in either the manual and thermostatic mode. The transmitter will operate the remote receiver from 1foot to a maximum of 30 feet. The distance is reduced when batteries are low or when the receiver is inside a metal enclosure. Initial Start-up 1. After initial power up or when RESET button is pressed, the transmitter is reset. The reset button is located behind the battery door of transmitter. 2. During system reset, all features of the LCD DISPLAY will be visible. After one second, the LCD will be initialized. A typical reset display is shown above. Note that the temperature scale is degree F. 3. Press On button to select between °C and °F display. It will exit setting mode automatically after 10 seconds if no key is pressed. The transmitter will send an Off signal after reset. 4. After reset, the transmitter is operating in manual mode. The room temperature is shown as above. Manual Mode: 1. Press the ON button once to turn on the appliance with max flame height. 2. Press the OFF button to decrease flame height. The first two press will decrease flame height to lower level. The third press will turn off the fireplace. 3. If OFF button is held for more than 3 seconds, the fireplace will be shut off. Thermostatic Mode: 1. Press the AUTO button to enter the thermostatic mode. 2. In thermostatic mode, press the ON / ▲ button or OFF / ▼ button to set the desired set temperature. 3. Once the setting is completed, the transmitter will automatically turn on the fireplace when the room temperature is below the set temperature and turn off the appliance when the room temperature is above the set temperature within 1 degree. 4. There will be a slight delay in the response of the unit (on/off) to a temperature. Room temperature is monitored every 3 minutes. 5. Press the AUTO button to exit the thermostatic mode. The transmitter will be in the manual off mode and the fireplace will be shut off. 3-Speed Bower Control: 1. Press FAN button once to enter blower speed setup mode at low speed initially and one of the three blade icon will display darken on LCD display. 2. Continue to press FAN button to set up the blower speed you desire. 3. If there is no input within 3 seconds, the new setting will be transmitted to receiver. If the fireplace is on, the blower speed will take effect right away; if the fireplace is off, the receiver will remember this setting and blower is still off. 4. If you continue to press FAN button to the position that all blades are gone, the FAN icon will disappear and turn the blower off. Blower On Delay Time and Off Delay Time Setting: 1. Hold FAN button for 3 seconds and two numbers will show up in LCD screen. The upper one is On Delay Time and the bottom is Off Delay Time in minutes. 2. Use the ON / ▲ button to set the desired On Delay Time from 0 to 15 min. 3. Use the OFF / ▼ button to set the desired Off Delay Time from 0 to 15 min. 4. If there is no input within 3 seconds, the new setting will be transmitted to receiver. 5. The default settings for both transmitter and receiver are 5 minutes for On Delay Time and 8 minutes for Off Delay Time, as shown in this picture.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : 3.1-701 Create Date : 2007:12:19 17:17:27Z Creator Tool : QuarkXPress(R) 7.31 Modify Date : 2008:08:29 15:06:19+08:00 Metadata Date : 2008:08:29 15:06:19+08:00 Producer : QuarkXPress(R) 7.31 X Press Private : %%DocumentProcessColors: Cyan Magenta Yellow Black.%%EndComments Format : application/pdf Title : MHNRTHC Document ID : uuid:11fdb5fc-1cba-4896-9900-73bfe583cfe3 Instance ID : uuid:c42bf3f8-5729-48a5-b6b6-6d7251252ea4 Page Count : 2 Creator : QuarkXPress(R) 7.31EXIF Metadata provided by EXIF.tools