Hand Held Full Function Remote
for Signature Command System
INSTALLATION AND OPERATING
INSTRUCTIONS
This remote control provides a safe, reliable and user-friendly
remote control for the signature command system. The system
can be manually or thermostatically turned on and off with the
transmitter. Always check the appliance home owner’s manual for
additional information, or warnings regarding accessory installation before using this remote control system.
Carefully inspect the contents for shipping damage. If any parts
are missing or damaged, immediately contact the dealer from
whom you purchased the kit or Ambient Technologies Technical
Support at 1 800 398 6195. Do not attempt to install any part of
the kit unless all parts are in good condition. Please keep this
booklet for future reference.
CONTENTS OF KIT
Description
Transmitter
Battery Alkaline AAA (for Transmitter)
Instructions
•
•
•
•
•
•
•
•
•
•
•
Qty
FEATURES/SPECIFICATIONS
Thermostatic Control
Battery Powered
Low battery Indication
Three Speed Control for Blower
Three Level of Light Brightness adjustment
Three Flame Height Settings
Auxiliary On/Off
Programmable Timer to turn blower on and off
Child Proof Lock-out
16 Security Codes
Reset Button
WARNING
Important Safety Information
WARNING
NOTE
• Read this manual thoroughly prior to programming or operating
any remote control.
• This remote control system requires three (3) “AAA” alkaline
batteries to power the transmitter.
• This remote control system should only be used as described in
this manual. Any other use is not recommended and will void
the warranty.
Due to the sensitive temperature monitoring
components in the transmitter, it is necessary to
allow the transmitter to stabilize to room temperature before accurate room temperatures are
displayed. If the transmitter is activated from a
severe cold condition, allow 15 minutes for accurate temperature readings to appear on the LCD
display.
Turn appliance OFF (at the appliance or remote
receiver) if you are away from your house for an
extended period of time. Never leave anything
on top of the surface of the transmitter. Any
modification of components will void the warranty and may cause a fire hazard.
Installing Batteries
INSTALLATIONS
The remote transmitter uses three (3) “AAA” batteries.
To install batteries,
1. Press down the battery door tab and pull out to remove the battery door.
2. Install the batteries as indicated on transmitter.
3. Close the battery door by snapping in place.
4. When three batteries are installed, the transmitter will initialize
for 10 seconds and then is ready for use.
5. The batteries should be replaced at least once every 6 months
or when the low battery icon indicator is displayed.
Setting Privacy (DIP) Switch on Transmitter:
The remote transmitter privacy (DIP) switches are preset at the
factory. In the event of activation or interference from other nearby transmissions, reset the code using the following procedures:
1. Slide the code switches on the transmitter to your choice of
ON or OFF position. Switches #1, #2, #3 and #4 are preset
to “ON” for the transmitter.
2. On the Command Center, hold the OFF button while turning
on the rocker switch (see figure).
3. Press ON button on the transmitter to learn. The receiver will
give two beeps if the learning is successful; if not, repeat 2.
4. The transmitter is now ready to operate.
Transmitter
Dip Switch
WARNING
RFSC
Hold OFF button while turning on the
rocker switch of the Command
Do not use two (2) or more remote control systems in the same area with the same dip switch
settings, as they will communicate with each
other. This may cause the appliances to malfunction.
Reset Button:
The reset button can be used to reset the transmitter if transmitter
is not working properly. The reset button is located behind the
battery door cover in the lower left corner of battery comparment.
Using a paper clip, press the reset button and the transmitter will
reset and initialize for 10 seconds before it can be used.
General
OPERATIONS
The RFSC Remote Control has two (2)
operating modes: Manual and Thermostatic.
The control system can be set to temperature range between 45°F and 90°F. The
blower speed and flame height can be
adjusted in either the manual and thermostatic mode.
The transmitter will operate the remote
receiver from 1foot to a maximum of 30
feet. The distance is reduced when batteries
are low or when the receiver is inside a
metal enclosure.
Initial Start-up
1. After initial power up or when
RESET button is pressed, the transmitter is reset. The reset button is
located behind the battery door of
transmitter.
2. During system reset, all features of
the LCD DISPLAY will be visible. After one second, the
LCD will be initialized. A typical reset display is shown
above. Note that the temperature scale is degree F.
3. Press On button to select between °C and °F display. It
will exit setting mode automatically after 10 seconds if no
key is pressed. The transmitter will send an Off signal
after reset.
4. After reset, the transmitter is operating in manual mode.
The room temperature is shown as above.
Manual Mode:
1. Press the ON button once to turn on
the appliance with max flame
height.
2. Press the OFF button to decrease
flame height. The first two press
will decrease flame height to lower
level. The third press will turn off
the fireplace.
3. If OFF button is held for more than
3 seconds, the fireplace will be shut
off.
Thermostatic Mode:
1. Press the AUTO button to enter the
thermostatic mode.
2. In thermostatic mode, press the ON
/ ▲ button or OFF / ▼ button to set
the desired set temperature.
3. Once the setting is completed, the
transmitter will automatically turn
on the fireplace when the room temperature is below the set temperature and turn off the appliance
when the room temperature is above the set temperature
within 1 degree.
4. There will be a slight delay in the response of the unit
(on/off) to a temperature. Room temperature is monitored
every 3 minutes.
5. Press the AUTO button to exit the thermostatic mode. The
transmitter will be in the manual off mode and the fireplace
will be shut off.
3-Speed Bower Control:
1. Press FAN button once to enter
blower speed setup mode at low
speed initially and one of the three
blade icon will display darken on
LCD display.
2. Continue to press FAN button to
set up the blower speed you desire.
3. If there is no input within 3 seconds, the new setting will be transmitted to receiver. If the fireplace
is on, the blower speed will take
effect right away; if the fireplace is off, the receiver will
remember this setting and blower is still off.
4. If you continue to press FAN button to the position that all
blades are gone, the FAN icon will disappear and turn the
blower off.
Blower On Delay Time and Off Delay Time Setting:
1. Hold FAN button for 3 seconds and two numbers will
show up in LCD screen. The upper one is On Delay Time
and the bottom is Off Delay Time in minutes.
2. Use the ON / ▲ button to set the desired On Delay Time
from 0 to 15 min.
3. Use the OFF / ▼ button to set the
desired Off Delay Time from 0 to
15 min.
4. If there is no input within 3 seconds, the new setting will be transmitted to receiver.
5. The default settings for both transmitter and receiver are 5 minutes
for On Delay Time and 8 minutes
for Off Delay Time, as shown in
this picture.


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-701
Create Date                     : 2007:12:19 17:17:27Z
Creator Tool                    : QuarkXPress(R) 7.31
Modify Date                     : 2008:08:29 15:06:19+08:00
Metadata Date                   : 2008:08:29 15:06:19+08:00
Producer                        : QuarkXPress(R) 7.31
X Press Private                 : %%DocumentProcessColors: Cyan Magenta Yellow Black.%%EndComments
Format                          : application/pdf
Title                           : MHNRTHC
Document ID                     : uuid:11fdb5fc-1cba-4896-9900-73bfe583cfe3
Instance ID                     : uuid:c42bf3f8-5729-48a5-b6b6-6d7251252ea4
Page Count                      : 2
Creator                         : QuarkXPress(R) 7.31
EXIF Metadata provided by EXIF.tools
FCC ID Filing: WLLRFSC

Navigation menu