Motorola Solutions 89FC3799 Non Broadcast Transmitter User Manual Summit BR 800 Tx FCC Filing 3
Motorola Solutions, Inc. Non Broadcast Transmitter Summit BR 800 Tx FCC Filing 3
Exhibit D Users Manual per 2 1033 c3
APPLICANT: MOTOROLA EQUIPMENT TYPE: ABZ89FC3799 User / Operational Manual Operational or User’s Manual The manual should include instruction, installation, operator, or technical manuals with required ‘information to the users’. This manual should include a statement that cautions the user that changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. The manual shall include RF Hazard warning statements, if applicable. Draft copy of some of the manual information has been assembled and has been included as part of this filing package. Upon request, published and/or printed manuals will be sent to the commission and/or telecommunication certification body (TCB). All of the descriptions, block diagrams, and schematics that are included in this filing package are current as of the package submittal date. EXHIBIT DESCRIPTION D1-1 Manual Front Matter (Draft) D1-2 Specifications (Draft) D1-3 Field Replaceable Units and Orderable Parts (Draft) D1-4 Tune-Up Procedure D1-5 Racking Configurations D1-6 Functional Description / Operation of Modules (Draft) EXHIBIT D APPLICANT: MOTOROLA EQUIPMENT TYPE: ABZ89FC3799 User / Operational Manual Manual Front Matter (Draft) EXHIBIT D1-1 APPLICANT: MOTOROLA EQUIPMENT TYPE: ABZ89FC3799 User / Operational Manual Manual Front Matter (Draft, Continued) EXHIBIT D1-1 APPLICANT: MOTOROLA EQUIPMENT TYPE: ABZ89FC3799 User / Operational Manual Manual Front Matter (Draft, Continued) EXHIBIT D1-1 APPLICANT: MOTOROLA EQUIPMENT TYPE: ABZ89FC3799 User / Operational Manual Manual Front Matter (Draft, Continued) EXHIBIT D1-1 APPLICANT: MOTOROLA EQUIPMENT TYPE: ABZ89FC3799 User / Operational Manual Specifications (Draft) General Performance Model HxWxD Weight Power Requirements T7039 5.25" x 19" x 18" (133x483x457mm) 46 lbs (21 kg) AC: 90-264 VAC, 47-63 Hz DC: 43.2-60 VDC -30 to 60C (-22 to 140F) 50 ohms Temperature Range Input / Output Impedance Antenna Connectors Transmit: N female Receive: N female Modulation IV&D Transmit / Receive: C4FM, LSM, H-DQPSK, TDMA Analog: Frequency Modulation Frequency Stability External Reference Channel Spacing Digital - C4FM, Linear Modulations: 12.5 kHz Analog Frequency Modulation: 12.5 kHz, 25 kHz Transmitter Frequency Range 136-174 MHz Power output C4FM Digital and Analog: 2-100 Watts Linear Digital Modulations: 2-100 Watts (Average) Electronic Bandwidth Intermodulation Attenuation Spurious and Harmonic Emissions Attenuation Full Bandwidth 55 dB 90 dB FCC Type Acceptance FCC Designation: ABZ89FC3799 ABZ89FR3791 Frequency Range 136-174 MHz 136-174 MHz Type Transmitter (FM) Transmitter (Linear) Receiver Power Output Variable 2-100 W Variable 2-100 W (Avg) N/A EXHIBIT D1-2 APPLICANT: MOTOROLA EQUIPMENT TYPE: ABZ89FC3799 User / Operational Manual Field Replaceable Units and Orderable Parts (Draft) Field replaceable units, or FRUs, include special packaging to allow shipment to customers. Parts and FRUs available for customer order are listed in this section. All parts and FRUs are sourced through the Radio Products and Service Division (RPSD). VHF Product OfferingP/NVHF PA – Power Amplifier CLD1315A Output Board / Low Pass Filter CLD6131A LDM – Linear driver module CLD6107B Distribution CLD6128B LFM – Final Module CLD6130A VHF XCVR –Transceiver PCUD1000B, PCUD2000B XCVR VHF RF kit CUD6000B RMC Pass Through Module MCLD6106A RMC Pass Through Module MCLD1309A VHF BR – Base Radio T7039A VHF – 6 pack includes expansion rack T7054A PMU – Power Monitoring Unit 0171259H01 Model/Option Description FRU Description CA00290AC INC: VHF 150-174 TRANSCEIVER DLN6568A FRU: AC / 48V DC Power Supply CA00292AC INC: VHF 136-174 PA 5985167Y02 FRU: Power Supply Fan Module CA00292AE INC: VHF 100W LINEAR 136-174 PA DLN6569A FRU: Site Controller X530BG ADD: VHF LINEAR PA (136-174 MHz) DLN6636A FRU: Expansion HUB X531BG ADD: VHF 100W LINEAR PA (136-174 MHz) DLN1380A FRU: Cabinet RMC Pass Through Module TFD6511A INC: PRESELCTOR VHF136-154 MHz DLN1338A FRU: Fan Module TFD6512A INC: PRESELCTOR VHF150-174 MHz DLN1329A FRU: Site Controller Backplane CA01170AA ADD: PMU VHF (136-174 MHz) DLN1330A FRU: Base Radio Backplane CA01164AA CABINET RMC PASS THROUGH MOD DLN1343A FRU: Expandable Site Subsystem Backplane DLN1339A FRU: AC Power Distribution Module X265AN NARROW PRESELECTOR, 136-154 MHz TFD6511A FRU: PRESELECTOR, 136-154 MHz X265AM NARROW PRESELECTOR, 150-174 MHz TFD6512A FRU: PRESELECTOR, 150-174 MHz X182CC DUPLEXER, 136-146 MHz 018541U01 DUPLEXER, 136-146 MHz X182CB DUPLEXER, 144-160 MHz 018541U02 DUPLEXER, 144-160 MHz X182CA DUPLEXER, 158-174 MHz 018541U03 DUPLEXER, 158-174 MHz CA01182AA VHF DUPLEXER HARDWARE KIT DLN1380A FRU: CABINET RMC PASS THROUGH MOD X676BJ EXT DUAL CIRCULATOR, 136-146 MHz 0185416U01 EXT DUAL CIRCULATOR, 136-146 MHz X676BI EXT DUAL CIRCULATOR, 144-160 MHz 0185416U02 EXT DUAL CIRCULATOR, 144-160 MHz X676BH EXT DUAL CIRCULATOR, 158-174 MHz 0185416U03 EXT DUAL CIRCULATOR, 158-174 MHz 9185856Y03 LOW PASS / HARMONIC FILTER VHF DLN1376A FRU: TRANSCEIVER VHF 136-174 T7321A GCM 8000 COMPARATOR DLN1431A FRU: TRANSCEIVER VHF 136-174 w/ SAC CA01183AA GCM 8000 COMPARATOR DLN1377A FRU: VHF 136-174 PA X153AW Rack Mount Hardware DLN6725A FRU: VHF 100W LINEAR 136-174 PA Customer Replaceable Power Cables for Standalone Base Radio Other Customer Replaceable Parts Part Number Description Part Number Description TRN7663A Power Cable, North America 3084827Y01 Battery Temperature Sensor Extension Cable TRN7755A Power Cable, Continental Europe 6484850Y01 Junction Panel (Cabinet Mounting) TTN5049A Power Cable, UK / Ireland 6485367Y01 Junction Panel (Rack Mounting) TTN5103A Power Cable, Australia EXHIBIT D1-3 APPLICANT: MOTOROLA EQUIPMENT TYPE: ABZ89FC3799 User / Operational Manual Field Replaceable Units and Orderable Parts (Draft) (Continued) EXHIBIT D1-3 APPLICANT: MOTOROLA EQUIPMENT TYPE: ABZ89FC3799 User / Operational Manual Tune-Up Procedure There is no field tune-up procedure. All adjustments are software controlled and are pre-set at the factory. Certain station operating parameters can be changed via man-machine interface (MMI) commands, within predetermined limits. Examples include transmit / receiver operating frequencies and transmitter power level. EXHIBIT D1-4 APPLICANT: MOTOROLA EQUIPMENT TYPE: ABZ89FC3799 User / Operational Manual Racking Configurations There are various equipment racking configurations available to customers. The following section includes sketches which depict many of the racking alternatives. Configuration Layout PA #5 PA #4 PA #6 Bay #3 Bay #2 PA #3 PA #2 PA PA #1 Bay #1 PS XCVR XCVR #6 XCVR #5 PS #5 SC #2 XCVR #4 PS #4 ALARM XCVR #3 XCVR #2 XCVR #2 SC #1 XCVR #1 PS XCVR #1 Base Radio Fan Module #1 serves PA Bay #1 Fan Module #2 serves PA Bay #2 Fan Module #3 serves PA Bay #3 Fan Module #4 serves XCVR Bay #1 Fan Module #5 serves XCVR Bay #2 Fan Module #6 serves XCVR Bay #3 PS #6 PS #3 PS #2 PS #1 Receive Only Base Radio GTR 8000 Expandable Site Sub-system Layout EXHIBIT D1-5 APPLICANT: MOTOROLA EQUIPMENT TYPE: ABZ89FC3799 User / Operational Manual Functional Description / Operation of Modules (Draft) Transceiver Module Overview The transceiver (XCVR) module provides receiver, exciter and base radio control functions. Receiver Overview The Receiver, which supports two-branch diversity, provides the receiver functions for the Base Radio. The receiver is a part of the ‘transceiver’ RF board and consists of a front end low noise amplifier section, an on board pre-selector section, an IF filter section, and a baseband converter section. The receiver Voltage Controlled Oscillator (VCO) and frequency synthesis circuitry blocks are also part of the receiver section. A digital decoding section for interface to the control section microprocessor also exists as part of the receiver module. The receiver interconnects to the control module using an 84-pin flex cable connector. There are no user controls or indicators on the receiver. For IV&D, only single branch is supported. The receiver also provides enhanced diagnostic capabilities. This includes receiver sensitivity checking, using on board calibrated noise generator. The receiver first local oscillator is high side injection. Exciter Overview The exciter, in conjunction with the Power Amplifier or PA, provides the transmitter functions for the Base Radio. The exciter, which is a part of ‘transceiver’ RF board, consists of a baseband circuit block, a baseband modulator circuit block, a pre-amplifier circuit block, and a final amplifier circuit block. The transmitter Voltage Controlled Oscillator (VCO) and frequency synthesis circuitry blocks are also part of the exciter. Other functional blocks in the exciter include the various DC voltage regulators which drive the different circuits, the digital decoding circuitry block which interfaces the exciter circuits to the microprocessor in the control section, metering capability, and exciter to receiver loopback capability for diagnostic purposes. The exciter interconnects to the control module using an 84-pin flex cable connector. There are no user controls or indicators on the exciter. The exciter uses a Cartesian feedback linearization scheme. The complete Cartesian feedback loop includes exciter and PA. The exciter includes an internal loop back feature which is used to perform exciter self diagnostic testing. The exciter also provides controlled output power level to power amplifier. Control Overview The Transceiver Control circuitry performs the control management, digital signal processing, and transmit and receive data formatting for the base radio (BR). The Host Processor is a Freescale MPC8250 and the main DSP is a Freescale MSC8101. A second DSP is a Texas Instrument device (TMS320VC5502) and is used for Block Encoding/Decoding. It also provides the various external interfaces described below. EXHIBIT D1-6 APPLICANT: MOTOROLA EQUIPMENT TYPE: ABZ89FC3799 User / Operational Manual Functional Description / Operation of Modules (Draft) The main operating software for the base radio is loaded in the transceiver’s control section. As the main manager for the base radio, the XCVR control board provides operational control over the other station modules. It handles three types of information flow, in the following ways: • Serves as a gateway between the network and RF functionality, by distributing the RF payload to and from the network • Supports operational and diagnostic functions with digital control data (for example: site information, channel assignments, and identification numbers for call processing) • Ensures the flow of other network management configuration information The External interfaces include three Ethernet ports per Transceiver. Two of the Ethernet ports on the Transceiver are used to communicate with the site controller. On single base radios these two Ethernet ports go to RJ45 connectors on the backplane. In the GTR 8000 Expandable Site Subsystem the site controller and transceiver connect directly via the backplane. These two Ethernet interfaces also contain TDM signals which are used to pass time reference, frequency reference and control data to the station. The third Ethernet port is located on the front panel of the Transceiver and is used as a Dedicated CSS Port. A RS232 port also resides on the front panel and is also used as a Dedicated CSS Port. Additional connections located behind the Fan Module are an asynchronous port, a synchronous port, and an alignment reference port. The synchronous port is used for V.24 application. Inter-module communication is achieved using a Serial Peripheral Interface (SPI) bus. The SPI bus allows communication with the slave devices consisting of the Power Supply, Receiver, Exciter and Power Amplifier modules. The Transceiver generates the station frequency reference which needs to be locked to one of many possible external sources of various frequencies. The external sources can be one of the site controller 20 MHz TDM clocks or an external reference operating at 5 or 10 MHz or 5 MHz/1pps composite signal. Status Indicators and Buttons There is one button on the Front Panel of the GTR 8000 Transceiver Module. This multifunction button can be used to reset the module or to place the transceiver in an access disable mode. The number and color scheme of the LEDs is application specific. The LEDs indicate the following states: Online, Failure, Impaired, Booting, Lamp Test, Receiver Inhibited, Receiver Active, Illegal Carrier, Control Channel (Operating), Control Channel (Failsoft), Service Mode, Transmitter Inhibited, Infrastructure Line Connected, EXHIBIT D1-6 APPLICANT: MOTOROLA EQUIPMENT TYPE: ABZ89FC3799 User / Operational Manual Functional Description / Operation of Modules (Draft) Infrastructure Link Disconnected, Software Download, VLAN, Detection, VLAN Split, Warning, Minor Hardware Failure, Major Hardware Failure, Critical Hardware Failure, Ethernet link status. Front Panel RS-232 / Ethernet (DB9) / RJ45 Interface The Front Panel port supports 2-wire RS-232 on a DB9 connector and 10/100BaseT Ethernet on a RJ45 connector. See tables below for connector pinout. Only the TXD and RXD signals are supported, no other handshake signals are provided. The table below shows the signals supported along with the Host hardware resource responsible the RS232 signals. The front panel also supports a 10/100BaseT Ethernet port. The connector is configured and an MDI-X port that can be connected to a laptop using a standard cable. In essence, the transmit and receive signal pairs are reversed on the BRC front panel compared to that defined in IEEE Std. 802.3 Clause 14.5.1. The Ethernet PHY is a Broadcom BCM5221. Its address (4:0) is '00100'. Both the Front Panel Ethernet PHYand the CP2 PHY (BCM5222) communicate to the Host via the "bit -banged" GPIO MDC and MDIO signals. Front Panel Port Signals RJ45 Pin # RS-232 Signal RD+ (Ethernet) RD- (Ethernet) TD+ (Ethernet) NC NC TD- (Ethernet) NC NC Front Panel RS232 Cable Adapter RJ45 Pin # RS232 DB9 / Female NC TXD (RS232) (Host PA9) RXD (RS232) (Host PA8) NC GND Ext_Trigger_In (DSP IRQ1) NC GND Ext_Trigger_Out (DSP PA20) Power Amplifier Module Overview The GTR 8000 Power Amplifier (PA) is a hot-swap capable, forced convection cooled RF power amplifier. It accepts a low-level modulated RF signal from the transceiver module, and amplifies it for transmission via the site transmit antenna. Also, to complete the Cartesian correction loop (GTR 8000’s linearization method), it provides a low level RF feedback signal to the transceiver module to achieve the required transmitter linearity. The power amplifier consists of the several sub-circuits and boards including core, driver, final, isolator, low pass filter, power converter and distribution. EXHIBIT D1-6 APPLICANT: MOTOROLA EQUIPMENT TYPE: ABZ89FC3799 User / Operational Manual Functional Description / Operation of Modules (Draft) There are three electrical connection assemblies on the PA: • Power supply/communications connector (backplane connection) • RF input/feedback connector (backplane connection) • RF output connector (front “quick-N” or QN connection) The PA is secured to the card cage with 2 TORX screws (T20 bit size required). The PA has 3 front panel LED indicators that work in concert with each other. Their meaning is as follows when the BR is powered: 1) PA TRANSMIT LED (Bi-Colored): - RED LIGHT indicates that the PA is transmitting at less than full requested power - GREEN LIGHT indicates that the PA is transmitting at full requested output power - NO LIGHT indicates that the PA is not in a transmitting state 2) PA STATUS LED: - GREEN LIGHT (on) indicates the PA is functioning normally - GREEN LIGHT (off) indicates a PA failure - GREEN LIGHT (blinking) the base radio is booting 3) PA ALARM LED: - RED LIGHT (on) indicates a PA failure - RED LIGHT (off) indicates that the PA is functioning normally - RED LIGHT (blinking) the PA is impaired The power amplifier (PA) module is a forced convection cooled RF power amplifier that operates to the following electrical performance specifications: - Maximum Rated Average Power Out: 110 Watt - Rated Peak Power Out: 200 Watt - Minimum Rated Average Power Out: 2 Watt - Nominal RF Gain: 42 dB - Nominal Input Supply Voltage: 29 Volts DC - Maximum Modulation Bandwidth: 25 kHz - Operational Frequency Range: 136 MHz to 174 MHz EXHIBIT D1-6 APPLICANT: MOTOROLA EQUIPMENT TYPE: ABZ89FC3799 User / Operational Manual Functional Description / Operation of Modules (Draft) The Power Amplifier is comprised of six internal modules. These are described briefly in the following paragraphs. 1. The Core Board provides the following functionality: - Routes DC to the Converter and Driver Boards - Routes RF to the Driver Board - Provides gain and FB power control - Provides for diagnostic sensors - Provides for intermediate voltages used by itself and other modules in the PA - Provides the PA’s digital interface to the rest of the Base Radio - Provides for cooling measures control - Provides for control of subordinate modules 2. The Power Converter Board provides the following functionality: - Provides 29 Volts DC and an intermediate voltage to the Distribution Board 3. The Driver Amplifier Board provides the following functionality: - Provides the first RF gain stage of the PA - Provides supporting bias circuits for the Driver Amplifier 4. The Final Amplifier Board provides the following functionality: - Provides the second RF gain stage of the PA (parallel stage) - Provides supporting bias circuits for the Final Amplifier - Provides for RF power splitting - Provides for RF power combining - Provides diagnostics 5. The Distribution Board provides the following functionality: - Provides for RF routing from the Driver Amplifier to the Final Amplifier - Provides for RF routing from the Final Amplifier to the Output Module - Provides for DC power routing from the Core Board to the Output Module - Provides for DC power routing from the Power Converter Board to the Final Amplifier - Provides for Forward and Reverse Power routing from the Output Module to the Core Board - Provides for feedback power coupling to the Core Board - Routes module control from the Core Board to the Final Module - Routes diagnostics from the Final Module to the Core Board 6. The Output Module provides the following functionality: - Provides output isolation to the PA - Provides for harmonic attenuation - Provides for forward and reverse power detection Power Supply Module Overview The power supply module operates from either an AC or DC input and provides the DC operating voltages for the other Base Radio modules. These modules are sometimes also referred to as field replaceable units (FRU). When operating from an AC source (90 to 264 VAC, 47 to 63 Hz), the supply generates two DC output voltages of 28.94 Volts with reference to output ground. The power supply automatically adjusts to AC input ranges and supplies a steady output. In AC mode, the power supply contains a separate battery charger which can be used to maintain the charge on a 48 Volt DC nominal system, positive or negative ground (if installed). EXHIBIT D1-6 APPLICANT: MOTOROLA EQUIPMENT TYPE: ABZ89FC3799 User / Operational Manual Functional Description / Operation of Modules (Draft) When operating from a DC source (43.2 VDC to 60 VDC, positive or negative ground), the supply generates two DC output voltages of 28.94 Volts with reference to output ground. The battery charger is not useable when operating from a DC input power source. When both AC and DC sources are available, the power supply operates from the AC source. When the AC source is lost, the power supply automatically shifts to DC operating mode. When the AC source is restored, the power supply automatically shifts to AC operating mode. Output is not interrupted when switching between AC and DC sources. The power supply contains several switching-type power supply circuits, power factor correction circuitry, battery charging circuitry, diagnostics and monitoring circuitry. The power supply module interconnects to the chassis backplane using a multi-pin power connector. Two Torx screws on the front panel of the power supply module secure it in the chassis. Power Supply Controls and Indicators The power supply module has three front panel light emitting diode (LED) indicators: 1) ALARM: a RED LED that when illuminated indicates the power supply is no longer operating within its design specifications 2) STATUS: a GREEN LED that when illuminated indicates the power supply is operating within its design specifications 3) FAN: a RED LED that when illuminated indicates the power supply fan is no longer functioning per its design specifications. The front panel ON/OFF switch is used to enable or disable the DC outputs of the power supply module. EXHIBIT D1-6 APPLICANT: MOTOROLA EQUIPMENT TYPE: ABZ89FC3799 User / Operational Manual Functional Description / Operation of Modules (Draft) Power Supply Performance Specifications Operating Temperature: -30 to +60 °C Input Voltage: 90 to 264 Volts AC 43.2 to 60 Volts DC AC: DC: Input Frequency Range (AC operation): 47 to 63 Hz Input Current: 10 Amps Maximum (120 VAC), 5 Amps Max (220/240 VAC) 18A maximum AC: DC: Steady-State Output Voltage: Main DC Output: Aux DC Output: 28.94 Volts DC +/- 2.7% 28.94 Volts DC +/- 3.0% Total Output Power Rating: DC Outputs: Battery Charger: 600 Watts 150 Watts Battery Charger Output Voltage Range: 45 to 58 Volts DC Battery Charger Output Current: 3 Amps maximum Output Ripple: All outputs 50 mV p-p (measured with 20 MHz BW oscilloscope at 25°C) Short Circuit Current: 0.5 Amp average (maximum) EXHIBIT D1-6
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Page Mode : UseOutlines XMP Toolkit : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:39 Producer : Acrobat PDFWriter 5.0 for Windows NT Create Date : 2005:09:16 15:08:59Z Modify Date : 2010:10:14 13:15:18-05:00 Metadata Date : 2010:10:14 13:15:18-05:00 Creator Tool : Summit-BR_800_Tx_FCC_Filing 3.doc - Microsoft Word Format : application/pdf Title : Summit-BR_800_Tx_FCC_Filing 3.doc Creator : cmic19 Document ID : uuid:a54fdb0f-d1a8-48ce-b90c-8666417da9d9 Instance ID : uuid:9c166f7a-b15a-4ef1-8489-70274528e5bc Has XFA : No Page Count : 17 Author : cmic19EXIF Metadata provided by EXIF.tools