Motorola Mb100 Users Manual MB_1_GHz_Data_Sheet_040307 Rev8

MB100 to the manual 8f0c900d-ac8c-4ae9-aedc-83161cc0cc1d

2015-01-23

: Motorola Motorola-Mb100-Users-Manual-272159 motorola-mb100-users-manual-272159 motorola pdf

Open the PDF directly: View PDF PDF.
Page Count: 6

Motorola, Inc.
101 Tournament Drive
Horsham, PA 19044
www.motorola.com/broadband
04.03.07
Rev 8
MOTOROLA, the Stylized M Logo, STARLINE, Mini-Bridger, and LIFELINE are registered in the US Patent & Trademark Office.
All other product or service names are the property of their respective owners.
© Motorola, Inc. 2006. All rights reserved.
Specifications are subject to change without notice.
Motorola’s 1 GHz STARLINE® Mini-Bridger® series amplifier, model
MB100*, leads the industry in features and performance and is designed to
meet the needs of today's expanding broadband communication networks.
This two-way capable dual output amplifier offers high gain, high output
levels, ergonomics, superior distortion performance, multiple diplex filter
options, 16 dB return loss, and Bode equalization. The MB100 also allows
optional advanced features such as ingress control switching and status
monitoring. A third output is user-configurable via splitter or directional
coupler plug-in. Single output models are also available.
ENHANCED GALLIUM ARSENIDE
The MB100 uses Enhanced Gallium Arsenide (E-GaAs) hybrids. This
second generation technology provides superior distortion performance in CTB and CSO over the standard GaAs
technology. Compared to silicon and competing GaAs technology, E-GaAs distortion performance remains linear at
significantly higher output levels. This higher output level allows the customer to maximize system performance and
reduce system costs. We encourage our customers to contact their Motorola Account Representative to determine the
optimal levels for their systems.
HIGH GAIN
The MB100 also offers high gain, which allows the operator to hold existing amplifier locations during system upgrades
thereby reducing system costs such as maintenance, installation and powering.
The MB100 two-way
amplifier offers 1 GHz
bandwidth capability,
high gain, high output
level, ergonomics, and
superior distortion
performance with the
option to bench upgrade
to N-split (5-85/104-1003
MHz) in the future.
MB100 1 GHz Amplifier
STARLINE® Series
BENEFITS INCLUDE:
1003 MHz Enhanced Gallium Arsenide (E-GaAs) power
doubling technology
High gain
High output level
Multiple diplex filter options
Future N-split (5-85/104-1003 MHz) availability
Ease-of-use ergonomics
16 dB return loss
60/90 V powering
Meets Telcordia GR-1098-Core voltage surge
requirements using surge waveforms as described in
IEEE C62.41
FCC, CENELEC and CCC approved
RoHS compliant models available Q1 2007
Bode equalization (thermal or auto controlled)
15 Ampere AC capability
Optional return path ingress control and status monitor
Power factor corrected power supply
Directional coupler –20 dB test points
Motorola, Inc.
101 Tournament Drive
Horsham, PA 19044
www.motorola.com/broadband
04.03.07
Rev 8
MOTOROLA, the Stylized M Logo, STARLINE, Mini-Bridger, and LIFELINE are registered in the US Patent & Trademark Office.
All other product or service names are the property of their respective owners.
© Motorola, Inc. 2006. All rights reserved.
Specifications are subject to change without notice.
2
BACKWARD COMPATIBILITY
The MB100 electronics package can be made backward compatible with the 10-Amp MB*/* housing by installing the MB-
15A Kit or the MB-15A Kit II. These kits contain 50 mil gold plated platform assemblies. This makes it possible for the
amplifier to carry 15 Amperes continuous through the input or output ports. There is also a “low current” (10A) model
available that can be ordered as an electronics module (no housing included), which is backward compatible with the 10-
Amp MB housing, without the use of a kit.
FORWARD PATH
The operational gain of the MB100 is 42 dB, with 16 dB return loss. Output level control is achieved through the use of
an interstage Bode equalizer, which compensates for coaxial cable attenuation changes due to temperature.
Equalization may be controlled manually, with a thermal drive unit (TDU), or with a single pilot closed loop automatic
drive unit, model ADU-* (analog pilot) or QADU-* (QAM pilot). Both the ADU and QADU boards are common to the
STARLINE family of amplifiers (with the exception of the SLE). ADUs utilize Surface Acoustic Wave (SAW) filters for
determining pilot frequency. This improves amplifier stability over temperature.
To further ensure system flexibility, installation ease and maintenance, the amplifier is engineered for compatibility with
standard accessories, such as attenuators, equalizers, ADUs or QADUs, return amplifiers, automotive fuses and FTEC
crowbar circuits.
For an optional third output, the MB100 utilizes splitters (model SP100) and directional couplers (model DC100/*). The
SP100, DC100/8, DC100/10, and DC100/12 offer superior performance to 1 GHz.
The MB100 uses modular diplex filters, which can be changed for a different frequency split as required. The amplifier is
available with S-split filters for a 5-40 MHz return and a 52-1003 MHz forward band. K-splits (5-42 MHz/54-1003 MHz),
J-splits (5-55 MHz/70-1003 MHz), and A-splits (5-65 MHz/85-1003 MHz) are also available. The N-split (5-85 MHz/104-
1003 MHz) option is currently in development. These same filters can be used for all US-style Motorola RF distribution
amplifiers (models BLE, MB/MBE, BT).
RETURN PATH
High gain return amplifier kits can be ordered which provide 20 dB minimum station gain. Return path equalizers from 0
to 12 dB can be customer selected. Optional features include thermal compensation and ingress control switching.
Thermal compensation comes in the form of a plug-in JXP-TH*C, which stabilizes gain and match over temperature
extremes.
Also available is Ingress Control Switching (ICS) in 3 states. This pin diode attenuator circuit can lower levels by 6 dB or
by 38 dB with a controlled slew rate for minimum bit errors. The LIFELINE® Mini-Bridger amplifier transponder (available
directly from AM Networks) is required to operate the Ingress Control Switch from a remote location.
Model Availability
To reduce customer costs and to accommodate customer specific needs, the STARLINE MB100 can be ordered in a
variety of different models. Please refer to the MB100 ordering information below for options.
Motorola, Inc.
101 Tournament Drive
Horsham, PA 19044
www.motorola.com/broadband
04.03.07
Rev 8
MOTOROLA, the Stylized M Logo, STARLINE, Mini-Bridger, and LIFELINE are registered in the US Patent & Trademark Office.
All other product or service names are the property of their respective owners.
© Motorola, Inc. 2006. All rights reserved.
Specifications are subject to change without notice.
3
STARLINE®
Enhanced Gallium Arsenide MB100S Specifications
1 GHz Mini-Bridger Amplifier RETURN
PARAMETER UNITS NOTE FORWARD RA-KIT/H
Passband MHz 1 5-40
Flatness dB 2 ± 0.50
Minimum Full Gain dB 3 NA
Operational Gain dB 4 20
Manual Bode Slope Control Range dB 5 NA
Interstage Equalizer Slope dB 6 NA
Noise Figure 40/52/1003MHz dB 7 8 / NA / NA
Reference Frequency MHz 8 1003 / 550 / 52
Output Level dBmV 45 / 44 / 37 35 flat
Channel Loading NTSC 79 6
Compressed data loading MHz 20 450 NA
Distortion (max) CTB dBc 9,19,21 76.5 88
XM dB 10,19 68.5 77
CSO dBc 9,11,19 71 81
Test Point (all) dB 12
Return Loss dB 13
Hum Modulation @ 12A dBc 14 60 (5 - 10 MHz)
70 (11 - 40 MHz)
Hum Modulation @ 15A 14 55 (5 - 10 MHz)
65 (11 - 40 MHz)
DC Voltage VDC 15
Current DC mA 16 1610
DC Ripple mV
Power Consumption W 48
AC Input Voltage Range VAC
AC Current Draw A 17 With Return
@90 VAC 0.55
@75 VAC 0.68
@60 VAC 0.81
@53 VAC 0.92
@45 VAC 1.08
@38 VAC 1.31
AC Bypass Current All Ports A 17
Group Delay (max) 18
55.25 to 58.83 MHz nSec NA
5.0 to 6.5 MHz nSec 45
10.0 to 11.5 MHz nSec 10
33.5 to 35.0 MHz nSec 12
38.5 to 40.0 MHz nSec 32
Housing Dimensions 15.4"L x 5.5"W x 9.6"D 39.1cm x 13.97cm x 24.3 cm
Weight 15 lbs 6.8 kg
Ambient Operating Temperature -40° to +140° F -40° to +60° C
65 (901 - 1003 MHz)
65 (52 - 900 MHz)
60 (901 - 1003 MHz)
NA
NA
2 Port, Parallel E-GaAs Hybrid
NA
NA
52-1003
± 0.70
46
0.62
16
1475
32
1.2
0.51
44.0
38 - 90
15 (or 10 amp option)
Forward Only
70 (52 - 900 MHz)
42
0.85
0.95
± 4
14 ±1
NA / 8 / 8
0.74
15 P-P
20 ±1.0
MB100 Specifications
All s
p
ecifications stated as worst
-
case over tem
p
erature unless otherwise noted.
Motorola, Inc.
101 Tournament Drive
Horsham, PA 19044
www.motorola.com/broadband
04.03.07
Rev 8
MOTOROLA, the Stylized M Logo, STARLINE, Mini-Bridger, and LIFELINE are registered in the US Patent & Trademark Office.
All other product or service names are the property of their respective owners.
© Motorola, Inc. 2006. All rights reserved.
Specifications are subject to change without notice.
4
Specification Notes:
1. Operating passband of station. Diplex filters are plugged into the electronic chassis.
2. Referenced to the average gain across the stated passband.
3. Minimum full gain at 1003 MHz includes loss of equalizer but Bode slope reserves have not been set. Return gain includes loss of SRE-*-4 return equalizer.
4. Operational gain includes loss of slope reserves as well as equalizer.
5. Amount of Bode slope control range from midpoint (typical setting is -4 dB at 1003 MHz @ 20°C). This control should not be used for gain reduction.
6. Amount of slope created and cable equivalence of fixed interstage equalizer. Interstage equalizer is a plug-in.
7. Noise Figure is specified at the cable entry facility of the housing and includes the loss of 1 dB for the pre-stage equalizer. The return Noise Figure includes the station loss preceding the RF
hybrid.
8. Frequencies that relate the picture carriers or passband edges to the specified output levels and tilts.
9. Measured with CW carriers and spectrum analyzer over specified temperature range. References the worst-case channel. Specifications are compliant with the test methods as stated in NCTA
RECOMMENDED PRACTICES FOR MEASUREMENTS ON CABLE TELEVISION SYSTEMS.
10. Measured with wave analyzer and synchronous, 100% depth modulated channels. References the worst-case channels over specified temperature range. Specifications are compliant with the
test methods as stated in NCTA RECOMMENDED PRACTICES FOR MEASUREMENTS ON CABLE TELEVISION SYSTEMS.
11. Composite Second Order distortion refers only to those beat clusters that fall +0.75 MHz and +1.25 MHz above the subject picture carrier. CSO beat clusters that have a -0.75 MHz and -1.25
MHz relationship to the subject picture carrier are not included in this specification.
12. Test points should be used with GFAL adaptor.
13. Match measurement at the station input and output, cable-entry facilities, at the specified passbands for operational gain.
14. Measured with the stated AC Bypass Current.
15. Measured at the power connector.
16. Current draw at +24.0 VDC.
17. AC current is stated in RMS continuous. A 10-amp compatible electronics package is also available for installing into older 10-amp housings during upgrades.
18. Group Delay is specified for standard NTSC video, where delay is the delta from picture carrier to 3.58 MHz color subcarrier. Reverse delay is in a 1.5 MHz bandwidth.
19. Distortion numbers are worst case over temperature in a cascade.
20. The compressed data loading is QAM carriers and are –6 dB relative to the analog CW carriers.
21. CTB (Composite Triple Beat). At the specified channel loading, Enhanced Gallium Arsenide performance varies on a two point three-for-one (2.3:1) basis with amplifier output level.
Input
port 1
Port
2
Port
4
Port
3
DC SP JMP
RF/
AC
RF/
AC
RF
RF
AC
AC
TP
TP
TP
(Status
Monitor
Output)
TP
TP
TP
H
L
**
**
**
**
JXP-B
JXP-B
JXP-B
** **
**
**** **
** **
**
SRE JXP-B
THERM
** **
JXPICS
JXPICS
Fuse
**
**
Fuse
Fuse
Fuse
Power
supply
Plug-in
module
24 Vdc
****
JXP-B
Manual Auto
ADU/
TDU
RF/AC
RF
AC
DC/
SP/
JMP
RF/
AC
RF
AC
To status
monitor
**
H
L
-1.0dB
-1.0dB
** **
JXP-B
BODE
-6.5 dB
**
MDR
-1.0 dB
-4.0 dB
-4.0 dB
H
L
**
-1.0dB
-1.0dB
-1.7 dB F
-1.0 dB R -20 dB
-20 dB
-20 dB
-20 dB
-20 dB
-20 dB
-1.7 dB F
-1.0dB R
-2.0 dB F
-1.0dB
-1.0dB
**
-1.0dB
SFE
or
SCS
PD
PD
+23 dB
PP
-1.0 dB R
-0.4dB
-0.5dB
Status
Monitor
Input
**
JXP-B
-16 dB
+30.0 dB -0.3dB
-4.0 dB
-4.0 dB
-0.4dB
-0.4dB
+20 dB
+20 dB
JXP-B
JXP-B
OnBrd
Atten
LPF
-0.4 dB
PP
+24 dB
RC
Therm
Cntrl HPF
~ -7.0 dB
4 dB
tilt
MB100 Block Diagram
Motorola, Inc.
101 Tournament Drive
Horsham, PA 19044
www.motorola.com/broadband
04.03.07
Rev 8
MOTOROLA, the Stylized M Logo, STARLINE, Mini-Bridger, and LIFELINE are registered in the US Patent & Trademark Office.
All other product or service names are the property of their respective owners.
© Motorola, Inc. 2006. All rights reserved.
Specifications are subject to change without notice.
5
Model Description Motorola
Part Number
Qty
per
MB
MB100S-2HQXH-F
5-40 / 52-1003 MHz S-split, two output, 42 dB high gain forward, QAM ADU 609.00 MHz
gain control, 14 dB internal slope, high gain return, full station 721000-001-00
MB100S-2HAXH-F
5-40 / 52-1003 MHz S-split, two output, 42 dB high gain forward, ADU 499.25 MHz gain
control, 14 dB internal slope, high gain return, full station 721000-002-00
MB100S-2HTXH-F
5-40 / 52-1003 MHz S-split, two output, 42 dB high gain forward, TDU gain control, 14 dB
internal slope, high gain return, full station 721000-003-00
MB100S-2HXXH-F
5-40 / 52-1003 MHz S-split, two output, 42 dB high gain forward, manual gain control, 14 dB
internal slope, high gain return, full station 721000-004-00
MB100S-1HXXH-F
5-40 / 52-1003 MHz S-split, one output, 42 dB high gain forward, manual gain control, 14 dB
internal slope, high gain return, full station 721000-005-00
MB100S-2HSXH-F
5-40 / 52-1003 MHz S-split, two output, 42 dB high gain forward, QAM ADU 711.00 MHz
gain control, 14 dB internal slope, high gain return, full station 721000-021-00
MB100S-2HXXH-E15
5-40 / 52-1003 MHz S-split, two output, 42 dB high gain forward, manual gain control, 14 dB
internal slope, high gain return, 15A electronics module only (no housing) 721000-006-00
MB2-100SH
(“vanilla” model)
5-40 / 52-1003 MHz S-split, 2-output, 42 dB high gain forward, manual gain control, 14 dB
internal slope, no return, standard surge arrestor (no FTEC), full station 535746-001-00
MB100K-2HQXH-F
5-42 / 54-1003 MHz K-split, two output, 42 dB high gain forward, QAM ADU 609.00 MHz
gain control, 14 dB internal slope, high gain return, full station 721000-010-00
MB100K-2HAXH-F
5-42 / 54-1003 MHz K-split, two output, 42 dB high gain forward, ADU 499.25 MHz gain
control, 14 dB internal slope, high gain return, full station 721000-011-00
MB100K-2HTXH-F
5-42 / 54-1003 MHz K-split, two output, 42 dB high gain forward, TDU gain control, 14 dB
internal slope, high gain return, full station 721000-012-00
MB100K-2HXXH-F
5-42 / 54-1003 MHz K-split, two output, 42 dB high gain forward, manual gain control, 14 dB
internal slope, high gain return, full station 721000-013-00
MB100K-1HXXH-F
5-42 / 54-1003 MHz K-split, one output, 42 dB high gain forward, manual gain control, 14 dB
internal slope, high gain return, full station 721000-014-00
MB100K-2HSXH-F
5-42 / 54-1003 MHz K-split, two output, 42 dB high gain forward, QAM ADU 711.00 MHz
gain control, 14 dB internal slope, high gain return, full station 721000-027-00
MB100K-2HXXH-E15
5-42 / 54-1003 MHz K-split, two output, 42 dB high gain forward, manual gain control, 14 dB
internal slope, high gain return, 15A electronics module only (no housing) 721000-015-00
MB2-100KH
(“vanilla” model)
5-42 / 54-1003 MHz K-split, 2-output, 42 dB high gain forward, manual gain control, 14 dB
internal slope, no return, standard surge arrestor (no FTEC), full station 535746-002-00
MB100A-2HXXH-F-R
5-65 / 85-1003 MHz A-split, 2-output, high gain, manual gain control, standard 14 dB slope,
high gain return, full station, RoHS compliant – AVAILABLE Q2 2007 821000-001-00
MB100J-2HXXH-F-R
5-55 / 70-1003 MHz A-split, 2-output, high gain, manual gain control, standard 14 dB slope,
high gain return, full station, RoHS compliant – AVAILABLE Q2 2007 821000-003-00
Required Accessories
SFE-100-0
SFE-100-1 to -22
SCS-1 to SCS-10
Starline Forward 1003 MHz equalizer (0 dB) -or-
Starline Forward 1003 MHz equalizer (values 1 to 22 dB in 1 dB steps) -or-
Starline Cable Simulator (values 1 to 10 dB in 1 dB steps)
527333-001-00
527296-001 to -022
477888-001 to -010
1
SRE-*-* Starline Return Equalizer, 5-40 MHz (S-split), 5-42 (K-split), 5-55 (J-split), 5-65 (A-split),
values 0-12 dB in 1 dB steps for S-split (2 dB steps for all other frequency splits)
478176-XXX-00 1
JXP-*B Plug-in attenuator/pad (values 0 to 26 dB, in 1 dB steps)
474011-XXX-00 9
(dual
output)
Optional Accessories
SP100
DC100/8
DC100/10
DC100/12
Splitter (1 GHz) to activate third output -or-
Directional Coupler (1 GHz) to activate third output (8 dB)
Directional Coupler (1 GHz) to activate third output (10 dB)
Directional Coupler (1 GHz) to activate third output (12 dB)
529863-001-00
529864-001-00
529864-002-00
529864-003-00
1
MB100 Ordering Information
Motorola, Inc.
101 Tournament Drive
Horsham, PA 19044
www.motorola.com/broadband
04.03.07
Rev 8
MOTOROLA, the Stylized M Logo, STARLINE, Mini-Bridger, and LIFELINE are registered in the US Patent & Trademark Office.
All other product or service names are the property of their respective owners.
© Motorola, Inc. 2006. All rights reserved.
Specifications are subject to change without notice.
6
See next page for ordering guide/matrix.
Key
2
1
Key
H
Key
XKey
AF
QE15
S
T
MB --
Key Key
100S H
100K
100A Key
100J X
100N
Key: Future options (not available today)
Two-port
Housing
Standard (Full Station)
1 GHz MB Ordering Guide
RF Configuration
Gain
Level Control
Electronics only (15 amp)
One-port
QADU - 609.00/S
E-GaAs (High Output w/ 42 dB Gain)
None
ADU - 499.25/S
TDU
Return Gain
High (20 dB)5 - 40 MHz / 52 - 1003 MHz
Bandpass Split
QADU - 711.00/S
5 - 85 MHz / 104 - 1003 MHz
Station Slope
14 dB (Fmin - 1003 MHz)
5 - 42 MHz / 54 - 1003 MHz
5 - 65 MHz / 85 - 1003 MHz
5 - 55 MHz / 70 - 1003 MHz
Notes:
1) Not all combinations in the ordering guide are available. This is a guide only. Please see “Ordering Information” (page 5) for available models.
2) FTECs are included in all models as standard, except for the “vanilla” models, MB2-100*H, which contain the standard gas tube.
3) 20A fuses are included in all amplifiers as standard.
4) ICS and status monitor transponders will continue to be customer configurable options.
5) For RoHS models, add “-R” to end of model string.

Navigation menu