Moxa WAPA003 IEEE 802.11a/b/g miniPCI module User Manual

Moxa Inc. IEEE 802.11a/b/g miniPCI module

User manual

AirWorks AWK-3121 User’s Manual Fifth Edition, May 2010 www.moxa.com/product  © 2010 Moxa Inc. All rights reserved. Reproduction without permission is prohibited.
AirWorks AWK-3121 User’s Manual The software described in this manual is furnished under a license agreement and may be used only in accordance with the terms of that agreement. Copyright Notice Copyright ©2010 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. Trademarks The MOXA logo is a registered trademark of Moxa Inc. All other trademarks or registered marks in this manual belong to their respective manufacturers. Disclaimer Information in this document is subject to change without notice and does not represent a commitment on the part of Moxa.  Moxa provides this document as is, without warranty of any kind, either expressed or implied, including, but not limited to, its particular purpose. Moxa reserves the right to make improvements and/or changes to this manual, or to the products and/or the programs described in this manual, at any time.  Information provided in this manual is intended to be accurate and reliable. However, Moxa assumes no responsibility for its use, or for any infringements on the rights of third parties that may result from its use.  This product might include unintentional technical or typographical errors. Changes are periodically made to the information herein to correct such errors, and these changes are incorporated into new editions of the publication. Technical Support Contact Information www.moxa.com/support Moxa Americas  Toll-free: 1-888-669-2872 Tel:   +1-714-528-6777 Fax:   +1-714-528-6778  Moxa China (Shanghai office)  Toll-free: 800-820-5036 Tel:   +86-21-5258-9955 Fax:   +86-10-6872-3958 Moxa Europe  Tel:    +49-89-3 70 03 99-0 Fax:    +49-89-3 70 03 99-99  Moxa Asia-Pacific  Tel:   +886-2-8919-1230 Fax:   +886-2-8919-1231
Table of Contents 1.Introduction ...................................................................................................................................... 1-1Overview ........................................................................................................................................... 1-2Package Checklist ............................................................................................................................... 1-2Product Features ................................................................................................................................ 1-2Product Specifications ......................................................................................................................... 1-3Functional Design ............................................................................................................................... 1-5LED Indicators ............................................................................................................................ 1-5Beeper ....................................................................................................................................... 1-6Reset Button ............................................................................................................................... 1-6Relay (Digital Output) .................................................................................................................. 1-62.Getting Started ................................................................................................................................. 2-1First-time Installation and Configuration ................................................................................................ 2-2Communication Testing ....................................................................................................................... 2-3Function Map ..................................................................................................................................... 2-53.Web Console Configuration ............................................................................................................... 3-1Web Browser Configuration .................................................................................................................. 3-2Overview ........................................................................................................................................... 3-3Basic Settings .................................................................................................................................... 3-4System Info Settings ................................................................................................................... 3-4Network Settings ......................................................................................................................... 3-5Time Settings ............................................................................................................................. 3-5Wireless Settings ................................................................................................................................ 3-7Operation Mode .................................................................................................................................. 3-7Basic Wireless Settings ........................................................................................................................ 3-8WLAN Security Settings ............................................................................................................. 3-10Advanced Wireless Settings ........................................................................................................ 3-16WLAN Certification Settings (for EAP-TLS in Client mode only) ........................................................ 3-19Advanced Settings ............................................................................................................................ 3-20Using Virtual LAN ...................................................................................................................... 3-20Configuring Virtual LAN .............................................................................................................. 3-21DHCP Server (for AP mode only) ................................................................................................. 3-22Packet Filters ............................................................................................................................ 3-23RSTP Settings (for AP mode only)................................................................................................ 3-25SNMP Agent ............................................................................................................................. 3-27Auto Warning Settings ....................................................................................................................... 3-29System Log .............................................................................................................................. 3-29Syslog ..................................................................................................................................... 3-30E-mail ...................................................................................................................................... 3-30Relay ....................................................................................................................................... 3-32Trap ........................................................................................................................................ 3-32Status ............................................................................................................................................. 3-33Associated Client List (for AP mode only)...................................................................................... 3-33DHCP Client List (for AP mode only) ............................................................................................ 3-34System Log .............................................................................................................................. 3-34Relay Status ............................................................................................................................. 3-35DI and Power Status .................................................................................................................. 3-35Wireless Status ......................................................................................................................... 3-35Maintenance .................................................................................................................................... 3-36Console Settings ....................................................................................................................... 3-36Ping ......................................................................................................................................... 3-36Firmware Upgrade ..................................................................................................................... 3-36Config Import Export ................................................................................................................. 3-37Load Factory Default .................................................................................................................. 3-37Password ................................................................................................................................. 3-37Misc. Settings ........................................................................................................................... 3-38Save Configuration ........................................................................................................................... 3-38Restart ............................................................................................................................................ 3-39Logout ............................................................................................................................................ 3-394.Software Installation and Configuration ........................................................................................... 4-1Overview ........................................................................................................................................... 4-2AWK Search Utility .............................................................................................................................. 4-2Installing AWK Search Utility ........................................................................................................ 4-2Configuring AWK Search Utility ..................................................................................................... 4-45.Other Console Considerations ........................................................................................................... 5-1RS-232 Console Configuration (115200, None, 8, 1, VT100) .................................................................... 5-2Configuration by Telnet and SSH Consoles ............................................................................................. 5-3Configuration by Web Browser with HTTPS/SSL ...................................................................................... 5-4
Disabling Telnet and Browser Access ..................................................................................................... 5-5A.References ........................................................................................................................................ A-1Wireless Distribution System (WDS) ..................................................................................................... A-2Beacon .............................................................................................................................................. A-3DTIM ................................................................................................................................................. A-3Fragment ........................................................................................................................................... A-3RTS Threshold .................................................................................................................................... A-3STP and RSTP .................................................................................................................................... A-4The STP/RSTP Concept ................................................................................................................ A-4Differences between RSTP and STP ................................................................................................ A-4B.Supporting Information .................................................................................................................... B-1About This User’s Manual ..................................................................................................................... B-2DoC (Declaration of Conformity) ........................................................................................................... B-2Federal Communication Commission Interference Statement ............................................................ B-2R&TTE Compliance Statement ....................................................................................................... B-3Firmware Recovery ............................................................................................................................. B-4
1  1. Introduction The AirWorks AWK-3121 enables wireless users to access network resources wirelessly. The AWK-3121 is rated to operate at temperatures ranging from 0 to 60°C for standard models and -40 to 75°C for wide temperature models, and is rugged enough for any harsh industrial environment. The following topics are covered in this chapter:  Overview  Package Checklist  Product Features  Product Specifications  Functional Design ¾ LED Indicators ¾ Beeper ¾ Reset Button ¾ Relay (Digital Output)
AirWorks AWK-3121  Introduction  1-2Overview The AWK-3121 Access-Point/Bridge and AP Client is ideal for applications that are hard to wire, too expensive to wire, or use mobile equipment that connects to a TCP/IP network. The AWK-3121 can operate at temperatures ranging from 0 to 60°C for standard models and -40 to 75°C for extended temperature models, and is rugged enough for any harsh industrial environment. Installation is easy, with either DIN-Rail mounting or wall mounting in distribution boxes. The DIN-Rail/wall mounting capability, wide operating temperature range, and IP30 housing with LED indicators make the AWK-3121 a convenient yet reliable solution for any industrial wireless application. Package Checklist Moxa’s AWK-3121 is shipped with the following items. If any of these items is missing or damaged, please contact your customer service representative for assistance. • 1 AWK-3121 • Swivel-type antennas (2dBi, RP-SMA, 2.4&5GHz) • Quick Installation Guide • Software CD • Moxa Product Warranty Card • Cable holder with 1 screw • Protective caps   NOTE The above items come with the standard AWK-3121 model, but the package contents may vary for customized versions.  Product Features • IEEE802.11a/b/g compliant • Three-in-one design (AP/Bridge/Client) • Advanced wireless security: ¾ 64-bit and 128-bit WEP/WPA/WPA2 ¾ SSID Hiding/IEEE 802.1X/RADIUS ¾ Packet access control & filtering • STP/RSTP support for network system redundancy • Long-distance transmission support • Turbo RoamingTM enables rapid handover (Client mode) • Dedicated antenna selection • Free firmware update for more advanced functions • RS-232 console management • 2DI+1DO for on-site monitoring and warnings • Wide -40 to 75°C operating temperature range (-T model) • Redundant 24 VDC power inputs or IEEE802.3af Power over Ethernet • DIN-Rail or wall mounting • IP30 protected high-strength metal housing
AirWorks AWK-3121  Introduction  1-3Product Specifications WLAN Interface Standards: IEEE 802.11a/b/g/h for Wireless LAN IEEE 802.11i for Wireless Security IEEE 802.3u for 10/100BaseT(X) IEEE 802.3af for Power-over-Ethernet IEEE 802.1D for Spanning Tree Protocol IEEE 802.1w for Rapid STP IEEE 802.1Q VLAN Spread Spectrum and Modulation (typical):  • DSSS with DBPSK, DQPSK, CCK • OFDM with BPSK, QPSK, 16QAM, 64QAM • 802.11b: CCK @ 11/5.5 Mbps, DQPSK @ 2 Mbps, DBPSK @ 11 Mbps • 802.11a/g: 64QAM @ 54/48 Mbps, 16QAM @ 36/24 Mbps, QPSK @ 18/12 Mbps, BPSK @ 9/6 Mbps Operating Channels (central frequency): US:  2.412 to 2.462 GHz (11 channels) 5.18 to 5.24 GHz (4 channels)  EU:  2.412 to 2.472 GHz (13 channels) 5.18 to 5.24 GHz (4 channels) JP:  2.412 to 2.472 GHz (13 channels, OFDM) 2.412 to 2.484 GHz (14 channels, DSSS) 5.18 to 5.24 GHz (4 channels for W52) Security: • SSID broadcast enable/disable • Firewall for MAC/IP/Protocol/Port-based filtering • 64-bit and 128-bit WEP encryption, WPA /WPA2-Personal and Enterprise (IEEE 802.1X/RADIUS, TKIP and AES) Transmission Rates:  802.11b: 1, 2, 5.5, 11 Mbps 802.11a/g: 6, 9, 12, 18, 24, 36, 48, 54 Mbps TX Transmit Power (for hardware revision 1.2):    802.11b: Typ. 23±1.5 dBm @ 1 to 11 Mbps 802.11g: Typ. 20±1.5 dBm @ 6 to 24 Mbps, Typ. 19±1.5 dBm @ 36 Mbps, Typ. 18±1.5 dBm @ 48 Mbps, Typ. 17±1.5dBm @ 54 Mbps 802.11a: Typ. 18±1.5 dBm @ 6 to 24 Mbps, Typ. 16±1.5 dBm @ 36 to 48 Mbps, Typ. 15±1.5 dBm @ 54 Mbps RX Sensitivity (for hardware revision 1.2):   802.11b: -97 dBm @ 1 Mbps, -94 dBm @ 2 Mbps, -92 dBm @ 5.5 Mbps, -90 dBm @ 11 Mbps 802.11g: -93 dBm @ 6 Mbps, -91 dBm @ 9 Mbps, -90 dBm @ 12 Mbps, -88 dBm @ 18 Mbps, -84 dBm @ 24 Mbps, -80 dBm @ 36 Mbps, -76 dBm @ 48 Mbps, -74 dBm @ 54 Mbps 802.11a: -90 dBm @ 6 Mbps, -89 dBm @ 9 Mbps, -89 dBm @ 12 Mbps, -85 dBm @ 18 Mbps, -83 dBm @ 24 Mbps, -79 dBm @ 36 Mbps, -75 dBm @ 48 Mbps, -74 dBm @ 54 Mbps
AirWorks AWK-3121  Introduction  1-4TX Transmit Power (for hardware revisions 1.0 and 1.1): 802.11b: Typ. 18±1.5 dBm @ 1 to 11 Mbps 802.11g: Typ. 18±1.5 dBm @ 6 to 24 Mbps, Typ. 16±1.5 dBm @ 36 to 48 Mbps, Typ. 15±1.5 dBm @ 54 Mbps 802.11a: Typ. 16±1.5 dBm @ 6 to 24 Mbps, Typ. 14±1.5 dBm @ 36 to 48 Mbps, Typ. 13±1.5 dBm @ 54 Mbps RX Sensitivity (for hardware revisions 1.0 and 1.1): 802.11b: -92 dBm @ 1 Mbps, -90 dBm @ 2 Mbps, -88 dBm @ 5.5 Mbps, -84 dBm @ 11 Mbps 802.11g: -87 dBm @ 6 Mbps, -86 dBm @ 9 Mbps, -85 dBm @ 12 Mbps, -82 dBm @ 18 Mbps, -80 dBm @ 24 Mbps, -76 dBm @ 36 Mbps, -72 dBm @ 48 Mbps, -70 dBm @ 54 Mbps 802.11a: -87 dBm @ 6 Mbps, -86 dBm @ 9 Mbps, -85 dBm @ 12 Mbps, -82 dBm @ 18 Mbps, -80 dBm @ 24 Mbps, -76 dBm @ 36 Mbps, -72 dBm @ 48 Mbps, -70 dBm @ 54 Mbps Protocol Support General Protocols: Proxy ARP, DNS, HTTP, HTTPS, IP, ICMP, SNTP, TCP, UDP, RADIUS, SNMP, PPPoE, DHCPAP-only Protocols: ARP, BOOTP, DHCP, dynamic VLAN-Tags for 802.1X-Clients, STP/RSTP (IEEE 802.1D/w)Interface Default Antenna: 2 dBi dual-band omni-directional antenna, RP-SMA (male) Connector for External Antennas: RP-SMA (female) LAN Ports: 1, 10/100BaseT(X), auto negotiation speed (RJ45-type) Console for External Antenna: RS-232 (RJ45-type) LED Indicators: PWR1, PWR2, PoE, FAULT, STATE, signal strength, CLIENT MODE, BRIDGE MODE, WLAN, 10M, 100M Alarm Contact: 1 relay output with current carrying capacity of 1 A @ 24 VDC Digital Inputs: 2 electrically isolated inputs • +13 to +30 V for state “1” • +3 to -30 V for state “0” • Max. input current: 8 mA Physical Characteristics Housing: Metal, providing IP30 protection Weight: 850 g Dimensions: 53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in) Installation: DIN-Rail mounting, wall mounting (with optional kit) Environmental Limits Operating Temperature: Standard Models: 0 to 60°C (32 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F) Storage Temperature: -40 to 85°C (-40 to 185°F) Ambient Relative Humidity: 5% to 95% (non-condensing) Power Requirements Input Voltage: 12 to 48 VDC, redundant dual DC power inputs or 48 VDC Power-over-Ethernet (IEEE 802.3af compliant) Connector: 10-pin removable terminal block Power Consumption: • 0.121 to 0.494 A @ 12 to 48 VDC • 0.3 A @ 24 VDC Reverse Polarity Protection: Present Regulatory Approvals Safety: EN60950-1, UL60950-1 Radio: EN300 328, EN301 893, ARIB STD-33/T66/T71 (Japan)
AirWorks AWK-3121  Introduction  1-5EMC: EN301 489-1/-17,  FCC Part 15, EN55022/55024, IEC61000-6-2/-4 Transportation: EN50155 (Environmental), EN50121-1/-4 (Environmental), Directive 72/245/EEC (for e/E-mark) Hazardous Location: UL/cUL Class I, Div. 2; ATEX Class I, Zone 2 Note: Please check Moxa’s website for the most up-to-date certification status. Warranty Warranty Period: 5 years Details: See www.moxa.com/warranty   ATTENTION • The AWK-3121 is NOT a portable mobile device and should be located at least 20 cm away from the human body.  • The AWK-3121 is NOT designed for the general public. A well-trained technician should be enlisted to ensure safe deployment of AWK-3121 units, and to establish a wireless network.  Functional Design LED Indicators The LEDs on the front panel of the AWK-3121 provide a quick and easy means of determining the current operational status and wireless settings. The FAULT LED indicates system failures and user-configured events. If the AWK-3121 cannot retrieve the IP address from a DHCP server, the FAULT LED will blink at one second intervals. The SIGNAL LEDs indicate signal strength, and only operate in Client mode. Signal StrengthLEDsFault LED The following table summarizes how to read the device’s wireless settings from the LED displays. More information is available in Chapter 3 in the “Basic Wireless Settings” section. Basic Wireless Settings  LEDs  Note Operation mode  WDS  CLIENT BRIDGE  SIGNAL AP Disabled off off – AP mode AP Enabled off on – Bridge mode: WDS is enabled Client  –  on  off  0  Client mode: no association Client – on off 1 Client mode: associated, poor signal Client – on off 2-5 Client mode: associated, good signal
AirWorks AWK-3121  Introduction  1-6 ATTENTION The FAULT, SIGNAL, CLIENT, BRIDGE, and WLAN LEDs lighting up simultaneously and blinking at one-second intervals indicates that the system has failed to boot. This may be due to improper operation or an uncontrollable factor, such as an unexpected shutdown during firmware update. Instructions on how to recover the firmware can be found in Chapter 6 in the “Firmware Recovery” section.  Beeper The beeper emits two short beeps when the system is ready. Reset Button The RESET button is located on the top panel of the AWK-3121. You can reboot the AWK-3121 or reset it to factory default settings by pressing the RESET button with a pointed object such as an unfolded paper clip. • System reboot: Hold the RESET button down for under 5 seconds and then release. • Reset to factory default: Hold the RESET button down for over 5 seconds until the STATE LED starts blinking green. Release the button to reset the AWK-3121.  Relay (Digital Output) The AWK-3121 has one relay output consisting of the 2 terminal block contacts on the top panel, as shown below. These relay contacts are used to forward system failures and user-configured events. The two wires attached to the relay contacts form an open circuit when a user-configured event is triggered. If a user-configured event does not occur, the relay circuit will remain closed. For safety reasons, the relay circuit is kept open when the AWK-3121 is not powered up. Summary of the AWK-3121’s Relay Status Power Status  Event  Relay Off – Open On Yes Open No Short
  2  2. Getting Started This chapter explains how to install Moxa’s AirWorks AWK-3121 for the first time, and quickly set up your wireless network and test whether the connection is running well. The function guide provides a convenient means of determining which functions you need to use. The following topics are covered in this chapter:  First-time Installation and Configuration  Communication Testing  Function Map
AirWorks AWK-3121  Getting Started  2-2First-time Installation and Configuration Before installing the AWK-3121, make sure that all items in the Package Checklist are in the box. You will need access to a notebook computer or PC equipped with an Ethernet port. The AWK-3121 has a default IP address that must be used when connecting to the device for the first time. • Step 1: Select the power source. The AWK-3121 can be powered by a DC power input or PoE (Power over Ethernet). The AWK-3121 will use whichever power source you choose. • Step 2: Connect the AWK-3121 to a notebook or PC. Since the AWK-3121 supports MDI/MDI-X auto-sensing, you can use either a straight-through cable or crossover cable to connect the AWK-3121 to a computer. The LED indicator on the AWK-3121’s LAN port will light up when a connection is established. • Step 3: Set up the computer’s IP address. Choose an IP address on the same subnet as the AWK-3121. Since the AWK-3121’s default IP address is 192.168.127.253, and the subnet mask is 255.255.255.0, you should set the IP address of the computer to 192.168.127.xxx. NOTE  After you select Maintenance Æ Load Factory Default and click the Submit button, the AWK-3121 will be reset to factory default settings and the IP address will be reset to 192.168.127.253.  • Step 4: Use the web-based manager to configure the AWK-3121 Open your computer’s web browser and type http://192.168.127.253 in the address field to access the homepage of the web-based Network Manager. Before the homepage opens, you will need to enter the user name and password as shown in the following figure. For first-time configuration, enter the default user name and password and then click on the Login button:  NOTE  Default user name and password:   User Name: admin   Password:  root For security reasons, we strongly recommend changing the default password. To do so, select Maintenance Æ Password, and then follow the on-screen instructions to change the password.
AirWorks AWK-3121  Getting Started  2-3NOTE  After you click Submit to apply changes the web page will refresh (Updated) will appear on the page and a blinking reminder will be shown on the upper-right corner of the web page:  To activate the changes click Restart and then Save and Restart after you change the settings. About 30 seconds are needed for the AWK-3121 to complete the reboot procedure.  • Step 5: Select the AWK-3121 operation mode. By default, the AWK-3121’s operation mode is set to AP. You can change to Client mode in Wireless Settings Æ Basic Wireless Settings. Detailed information about configuring the AWK-3121’s operation can be found in Chapter 3. • Step 6: Test communications. In the following sections we describe two test methods that can be used to ensure that a network connection has been established. Communication Testing After installing the AWK-3121 you can run a sample test to make sure the AWK-3121 and wireless connection are functioning normally. Two testing methods are described below. Use the first method if you are using only one AWK-3121 device, and use the second method if you are using two or more AWK-3121 units. How to Test One AWK-3121 If you are only using one AWK-3121, you will need a second notebook computer equipped with a WLAN card. Configure the WLAN card to connect to the AWK-3121 (NOTE: the default SSID is MOXA), and change the IP address of the second notebook (Notebook B) so that it is on the same subnet as the first notebook (Notebook A), which is connected to the AWK-3121. After configuring the WLAN card, establish a wireless connection with the AWK-3121 and open a DOS window on Notebook B. At the prompt, type ping <IP address of notebook A> and then press Enter (see the figure below). A “Reply from IP address …” response means the communication was successful. A “Request timed out.” response means the communication failed. In this case, recheck the configuration to make sure the connections are correct.
AirWorks AWK-3121  Getting Started  2-4How to Test Two or More AWK-3121 Units If you have two or more AWK-3121 units, you will need a second notebook computer (Notebook B) equipped with an Ethernet port. Use the default settings for the first AWK-3121 connected to notebook A and change the second or third AWK-3121 connected to notebook B to Client mode, and then configure the notebooks and AWK-3121 units properly.  After setting up the testing environment, open a DOS window on notebook B. At the prompt, type: ping <IP address of notebook A> and then press Enter. A “Reply from IP address …” response means the communication was successful. A “Request timed out” response means the communication failed. In this case, recheck the configuration to make sure the connections are correct.
AirWorks AWK-3121  Getting Started  2-5Function Map    Basic settings for administering the AWK-3121 Essential settings related to establishing a wireless network Advanced features to support additional network management and secure wired and wireless communication  Note: These advanced functions are all optional. Application-oriented device management functions to set up events, traps, and reactions via relay warning, e-mail, and SNMP notification  Note: These functions are all optional. Real-time status information for monitoring wired/wireless network performance, advanced services, and device management functions. Functions for maintaining the AWK-3121, and for diagnosing the network. On-demand functions to support the web-based console management operation. Quick overview of the AWK-3121’s status
  3  3. Web Console Configuration In this chapter, we explain all aspects of web-based console configuration. Moxa’s easy-to-use management functions help you set up your AWK-3121 and make it easy to establish and maintain your wireless network. The following topics are covered in this chapter:  Web Browser Configuration  Overview  Basic Settings ¾ System Info Settings ¾ Network Settings ¾ Time Settings  Wireless Settings  Operation Mode  Basic Wireless Settings ¾ WLAN Security Settings ¾ Advanced Wireless Settings ¾ WLAN Certification Settings (for EAP-TLS in Client mode only)  Advanced Settings ¾ Using Virtual LAN ¾ Configuring Virtual LAN ¾ DHCP Server (for AP mode only) ¾ Packet Filters ¾ RSTP Settings (for AP mode only) ¾ SNMP Agent  Auto Warning Settings ¾ System Log ¾ Syslog ¾ E-mail ¾ Relay ¾ Trap  Status ¾ Associated Client List (for AP mode only) ¾ DHCP Client List (for AP mode only) ¾ System Log ¾ Relay Status ¾ DI and Power Status ¾ Wireless Status   Maintenance ¾ Console Settings ¾ Ping ¾ Firmware Upgrade ¾ Config Import Export ¾ Load Factory Default ¾ Password ¾ Misc. Settings  Save Configuration  Restart  Logout
AirWorks AWK-3121  Web Console Configuration  3-2Web Browser Configuration Moxa AWK-3121’s web browser interface provides a convenient way to modify its configuration and access the built-in monitoring and network administration functions. The recommended web browser is Microsoft® Internet Explorer 7.0 or 8.0 with JVM (Java Virtual Machine) installed. NOTE  To use the AWK-3121’s management and monitoring functions from a PC host connected to the same LAN as the AWK-3121, you must make sure that the PC host and the AWK-3121 are on the same logical subnet. Similarly, if the AWK-3121 is configured for other VLAN settings, you must make sure your PC host is on the management VLAN. The Moxa AWK-3121’s default IP is 192.168.127.253.  Follow these steps to access the AWK-3121’s web-based console management interface. 1. Open your web browser (e.g., Internet Explorer) and type the AWK-3121’s IP address in the address field. Press Enter to establish the connection.  2. The Web Console Login page will open. Enter the password (default Username = admin; default Password = root) and then click Login to continue.  3. You may need to wait a few moments for the web page to download to your computer. Note that the Model name and IP address of your AWK-312 are both shown in the title bar of the web page. This information can be used to help you identify multiple AWK-3121 units.
AirWorks AWK-3121  Web Console Configuration  3-34. Use the menu tree on the left side of the window to open the function pages to access each of the AWK-3121’s functions.  In the following paragraphs, we describe each AWK-3121 management function in detail. A quick overview is available in this manual in the “Function Map” section of Chapter 2. NOTE  The model name of the AWK-3121 is shown as AWK-3121-XX, where XX indicates the country code. The country code indicates the AWK-3121 version and which bandwidth it uses. We use AWK-3121-US as an example in the following figures. (The country code and model name that appears on your computer screen may be different than the one shown here.)   NOTE  For security reasons, you will need to log back into the AWK-3121 after a 5-minute time-out.  Overview The Overview page summarizes the AWK-3121’s current status. The information is categorized into several groups: System info, Device info, and 802.11 info.
AirWorks AWK-3121  Web Console Configuration  3-4Click on SSID for more detailed 802.11 information, as shown in the following figure.   NOTE The 802.11 info that is displayed may be different for different operation modes. For example, “Current BSSID” is not available in Client mode, and “Signal strength” is not available in AP mode.  Basic Settings The Basic Settings group includes the most commonly used settings required by administrators to maintain and control the AWK-3121. System Info Settings The System Info items, especially Device name and Device description, are displayed and included on the Overview page, in SNMP information, and in alarm emails. Setting System Info items makes it easier to identify the different AWK-3121 units connected to your network.  Device name Setting  Description  Factory Default Max. 31 of characters  This option is useful for specifying the role or application of different AWK-3121 units.  AWK-3121_<Serial No. of this AWK-3121> Device location Setting  Description  Factory Default Max. of 31 characters  Specifies the location of different AWK-3121 units.  None Device description Setting  Description  Factory Default Max. of 31 characters  Use this space to record amore detailed description of the AWK-3121  None
AirWorks AWK-3121  Web Console Configuration  3-5Device contact information Setting  Description  Factory Default Max. of 31 characters  Provides information about whom to contact in order to resolve problems. Use this space to record contact information of the person responsible for maintaining this AWK-3121. None Network Settings The Network Settings configuration panel allows you to modify the usual TCP/IP network parameters. An explanation of each configuration item is given below.  IP configuration Setting  Description  Factory Default DHCP  The AWK-3121’s IP address will be assigned automatically by the network’s DHCP server  Static Static  Set up the AWK-3121’s IP address manually. IP address Setting  Description  Factory Default AWK-3121’s IP address  Identifies the AWK-3121 on a TCP/IP network.  192.168.127.253 Subnet mask Setting  Description  Factory Default AWK-3121’s subnet mask  Identifies the type of network to which the AWK-3121 is connected (e.g., 255.255.0.0 for a Class B network, or 255.255.255.0 for a Class C network). 255.255.255.0 Gateway Setting  Description  Factory Default AWK-3121’s default gateway  The IP address of the router that connects the LAN to an outside network.  None Primary/ Secondary DNS server Setting  Description  Factory Default IP address of the Primary/Secondary DNS server The IP address of the DNS Server used by your network. After entering the DNS Server’s IP address, you can input the AWK-3121’s URL (e.g., http://ap11.abc.com) in your browser’s address field instead of entering the IP address. The Secondary DNS server will be used if the Primary DNS server fails to connect. None Time Settings The AWK-3121 has a time calibration function based on information from an NTP server or user specified Date and Time information. Functions such as Auto warning can add real-time information to the message.
AirWorks AWK-3121  Web Console Configuration  3-6 The Current local time shows the AWK-3121’s system time when you open this web page. You can click on the Set Time button to activate the updated date and time parameters. An “(Updated)” string will appear to indicate that the change is complete. Local time settings will be immediately activated in the system without running Save and Restart. NOTE  The AWK-3121 has a built-in real time clock (RTC). We strongly recommend that users update the Local time for the AWK-3121 after the initial setup or a long-term shutdown, especially when the network does not have an Internet connection for accessing the NTP server or there is no NTP server on the LAN.  Current local time Setting  Description  Factory Default User adjustable time  The date and time parameters allow configuration of the local time, with immediate activation.  Use 24-hour format: yyyy/mm/dd hh:mm:ss None Time zone Setting  Description  Factory Default User selectable time zone  The time zone setting allows conversion from GMT (Greenwich Mean Time) to local time.  GMT (Greenwich Mean Time)   ATTENTION Changing the time zone will automatically adjust the Current local time. You should configure the Time zone before setting the Current local time.  Daylight saving time Setting  Description  Factory Default Enable/ Disable  Daylight saving time (also know as DST or summer time) involves advancing clocks (usually 1 hour) during the summer time to provide an extra hour of daylight in the afternoon. Disable When Daylight saving time is enabled, the following parameters will be shown: • Starts at: The date that daylight saving time begins. • Stops at: The date that daylight saving time ends. • Time offset: Indicates how many hours forward the clock should be advanced. Time server 1/2 Setting  Description  Factory Default IP/Name of Time Server 1/2  IP or Domain name of the NTP time server. The 2nd NTP server will be used if the 1st NTP server fails to connect.  None
AirWorks AWK-3121  Web Console Configuration  3-7Query period Setting  Description  Factory Default Query period time (1 to 9999 seconds)  This parameter determines how often the time is updated from the NTP server.  600 (seconds) Wireless Settings The essential settings for wireless networks are presented in this function group. Settings must be properly set before establishing your wireless network. Familiarize yourself with the following terms before starting the configuration process: AP/Bridge: This mode provides both Access Point and Static LAN-to-LAN Bridging functionality. The static LAN-to-LAN bridging function is supported by the Wireless Distribution System (WDS). AP Client: This mode is for Dynamic LAN-to-LAN Bridging or Device-to-LAN scenarios. The AP Client automatically establishes bridge links with other APs. In either AP/Bridge or AP Client mode, the AWK-3121 forwards packets between its Ethernet interface (LAN) and wireless interface (WLAN) to connect wired hosts on the Ethernet side with wireless host(s) on the wireless side. There are two types of wireless links are specified by the IEEE802.11 standard: • STA-AP: This type of wireless link is established between an IEEE802.11 Station (STA) and an IEEE802.11 Access Point (AP). An STA is usually a client computer (PC or PDA) with a WLAN network interface card (NIC). The Client mode is actually an STA. • WDS: This type of wireless link is established between two IEEE802.11 APs. Wireless packets transmitted along the WDS link comply with the IEEE802.11 WDS (Wireless Distribution System) format at the link layer. Refer to the “Wireless Distribution System (WDS)” section in Chapter 5 for details. Keep in mind that WPA/WPA2 CANNOT be supported in WDS. To establish a static bridge link based on the WDS, the APs at both end of the WDS link must be configured manually with each other’s MAC addresses. To establish a dynamic bridge link between an AP and a Client, both devices must be configured with the same channel, and security settings (see “WLAN Security Settings” for details). Moreover, the same SSID is also needed for clients that roam the APs in Bridge mode. The AP Client automatically scans for any AP that is using the matched SSID and establishes a bridge link with the scanned AP. When the AWK-3121 is configured for Client mode, it can be used as an Ethernet-to-wireless (or LAN-to-WLAN) network adapter. For example, a notebook computer equipped with an Ethernet adaptor but no wireless card can be connected to this device with an Ethernet cable to provide wireless connectivity to another AP. NOTE  Although it is more convenient to use dynamic bridging, there is a limitation—the AP Client can only transmit IP-based packets between its wireless interface (WLAN) and Ethernet interface (LAN); other types of traffic (such as IPX and AppleTalk) are not forwarded.  Operation Mode The AWK-3121 supports two main operation modes—Client and AP—each of which plays a distinct role on the wireless network.
AirWorks AWK-3121  Web Console Configuration  3-8Wireless Enable Setting  Description  Factory Default Enable/Disable  The RF (Radio Frequency) module can be manually turned on or off. This function is available in AP operation mode only.  Enable Operation Mode Setting  Description  Factory Default AP  The AWK-3121 plays the role of wireless AP/Bridge  AP Client  The AWK-3121 plays the role of wireless AP Client Basic Wireless Settings The “WLAN Basic Setting Selection” panel is used to add and edit SSIDs. An SSID is a unique identifier that wireless networking devices use to establish and maintain wireless connectivity. Multiple access points on a network or sub-network can use the same SSIDs. You can configure your AWK to use up to 9 SSIDs, and configure each SSID differently. All of the SSIDs are active at the same time; that is, client devices can use any of the SSIDs to associate with the access point.  Click on Add SSID to create more SSIDs. Click on Edit to assign different configuration settings to each SSID. The configuration panel appears as follows:
AirWorks AWK-3121  Web Console Configuration  3-9 NOTE When you switch to Client mode, a Site Survey button will be available on the Basic Wireless Settings panel. Click the “Site Survey” button to view information about available APs, as shown in the following figure. You can click on the SSID of an entity and bring the value of its SSID onto the SSID field of the Basic Wireless Settings page. Click the Refresh button to re-scan and update the table.      NOTE If the Gateway field in Basic Settings Æ Network Settings is empty, a warning message will appear, reminding you to set the default gateway when Client mode is enabled. You can ignore this message if you are only planning a local network and packets will not be sent outside the network.  RF type Setting  Description  Factory Default A  Supports IEEE802.11a standard only  B/G Mixed  B  Supports IEEE802.11b standard only G  Supports IEEE802.11g standard only B/G Mixed  Supports both of IEEE802.11b/g standards, but 802.11g can be slowed down when 802.11b clients are on the network Channel (for AP mode only) Setting  Description  Factory Default Available channels vary with RF type  AWK-3121 plays a role of wireless AP.  6 (in B/G Mixed mode) SSID Setting  Description  Factory Default Max. of 31 characters  The SSID of a client and the SSID of the AP must be identical for the client and AP to be able to communicate with each other.  MOXA
AirWorks AWK-3121  Web Console Configuration  3-10SSID broadcast (for AP mode only) Setting  Description  Factory Default Enable/ Disable  SSID can be broadcast or not  Enable   NOTE The AWK-3121-JP (for Japanese frequency bands) only connects SSID-hidden APs in all IEEE802.11a channels and IEEE802.11g channels 1 to 11. The AWK-3121-EU (for European frequency bands) only connects SSID-hidden APs in all IEEE802.11b/g channels.  WDS (for AP mode only) Setting  Description  Factory Default Enable/Disable  AWK-3121 supports WDS or not.  Disable   NOTE When WDS is enabled, you can use a pure point-to-point WDS link by disabling AP functionality. The AWK-3121 provides 8 entities for WDS settings and can support up to 8 WDS links to other APs or wireless bridges. The list appears when WDS Enable is checked. Enter the MAC address to set up a WDS link. Remember to activate a WDS link by checking the Active check box.   WLAN Security Settings The AWK-3121 provides four standardized wireless security modes: Open, WEP (Wired Equivalent Privacy), WPA (Wi-Fi Protected Access), and WPA2. Several security modes are available in the AWK-3121 by selecting Security mode and WPA type: • Open: No authentication, no data encryption. • WEP: Static WEP (Wired Equivalent Privacy) keys must be configured manually. • WPA/WPA2-Personal: Also known as WPA/WPA2-PSK. You will need to specify the Pre-Shared Key in the Passphrase field, which will be used by the TKIP or AES engine as a master key to generate keys that actually encrypt outgoing packets and decrypt incoming packets. • WPA/WPA2-Enterprise: Also called WPA/WPA2-EAP (Extensible Authentication Protocol). In addition to device-based authentication, WPA/WPA2-Enterprise enables user-based authentication via IEEE802.1X. The AWK-3121 can support three EAP methods: EAP-TLS, EAP-TTLS, and EAP-PEAP.
AirWorks AWK-3121  Web Console Configuration  3-11Security mode Setting  Description  Factory Default Open No authentication  Open WEP  Static WEP is used WPA* WPA is used WPA2*  Fully supports IEEE802.11i with “TKIP/AES + 802.1X” *WPA and WPA2 are not supported in WDS (Bridge) mode. Open For security reasons, you should NOT set security mode to Open System, since authentication and data encryption are NOT performed in Open System mode. WEP According to the IEEE802.11 standard, WEP can be used for authentication and data encryption to maintain confidentiality. Shared (or Shared Key) authentication type is used if WEP authentication and data encryption are both needed. Normally, Open (or Open System) authentication type is used when WEP data encryption is run with authentication. When WEP is enabled as a security mode, the length of a key (so-called WEP seed) can be specified as 64/128 bits, which is actually a 40/104-bit secret key with a 24-bit initialization vector. The AWK-3121 provides 4 entities of WEP key settings that can be selected to use with Key index. The selected key setting specifies the key to be used as a send-key for encrypting traffic from the AP side to the wireless client side. All 4 WEP keys are used as receive-keys to decrypt traffic from the wireless client side to the AP side. The WEP key can be presented in two Key types, HEX and ASCII. Each ASCII character has 8 bits, so a 40-bit (or 64-bit) WEP key contains 5 characters, and a 104-bit (or 128-bit) key has 13 characters. In hex, each character uses 4 bits, so a 40-bit key has 10 hex characters, and a 128-bit key has 26 characters.  Authentication type Setting  Description  Factory Default Open  Data encryption is enabled, but without authentication  Open Shared  Data encryption and authentication are both enabled. Key type Setting  Description  Factory Default HEX  Specifies WEP keys in hex-decimal number form  HEX ASCII  Specifies WEP keys in ASCII form Key length Setting  Description  Factory Default 64 bits  Uses 40-bit secret keys with 24-bit initialization vector  64 bits 128 bits  Uses 104-bit secret key with 24-bit initialization vector Key index Setting  Description  Factory Default 1-4  Specifies which WEP key is used  Open
AirWorks AWK-3121  Web Console Configuration  3-12WEP key 1-4 Setting  Description  Factory Default ASCII type: 64 bits: 5 chars 128 bits: 13chars HEX type: 64 bits: 10 hex chars 128 bits: 26 hex chars A string that can be used as a WEP seed for the RC4 encryption engine.  None WPA/WPA2-Personal WPA (Wi-Fi Protected Access) and WPA2 represent significant improvements over the WEP encryption method. WPA is a security standard based on 802.11i draft 3, while WPA2 is based on the fully ratified version of 802.11i. The initial vector is transmitted, encrypted, and enhanced with its 48 bits, twice as long as WEP. The key is regularly changed so that true session is secured. Even though AES encryption is only included in the WPA2 standard, it is widely available in the WPA security mode of some wireless APs and clients as well. The AWK-3121 also supports AES algorithms in WPA and WPA2 for better compatibility. Personal versions of WPA/WPA2, also know as WPA/WPA-PSK (Pre-Shared Key), provide a simple way of encrypting a wireless connection for high confidentiality. A Passphrase is used as a basis for encryption methods (or cipher types) in a WLAN connection. The passphrases should be complicated and as long as possible. There must be at least 8of ASCII characters in the Passphrase, and it could go up to 63. For security reasons, this passphrase should only be disclosed to users who need it, and it should be changed regularly.  WPA type Setting  Description  Factory Default Personal  Provides Pre-Shared Key-enabled WPA and WPA2  Personal Enterprise Provides enterprise-level security for WPA and WPA2 Encryption method Setting  Description  Factory Default TKIP Temporal Key Integrity Protocol is enabled  TKIP AES  Advance Encryption System is enabled Mixed*  Provides TKIP broadcast key and TKIP+AES unicast key for some legacy AP clients. This option is rarely used. *This option is available in AP mode only, and does not support AES-enabled clients. Passphrase Setting  Description  Factory Default 8 to 63 characters  Master key to generate keys for encryption and decryption  None Key renewal (for AP mode only) Setting  Description  Factory Default 60 to 86400 seconds (1 minute to 1 day)  Specifies the time period of group key renewal  3600 (seconds)
AirWorks AWK-3121  Web Console Configuration  3-13 NOTE The key renewal value dictates how often the wireless AP encryption keys should be changed. The security level is generally higher if you set the key renewal value to a shorter number, which forces the encryption keys to be changed more frequently. The default value is 3600 seconds (6 minutes). Longer time periods can be considered if the line is not very busy.  WPA/WPA2-Enterprise (for AP mode) By setting WPA type to Enterprise, you can use EAP (Extensible Authentication Protocol), a framework authentication protocol used by 802.1X to provide network authentication. In these Enterprise-level security modes, a back-end RADIUS (Remote Authentication Dial-In User Service) server is needed if IEEE 802.1X functionality is enabled in WPA /WPA2. The IEEE 802.1X protocol also offers the possibility of carrying out an efficient connection authentication on a large-scale network. It is not necessary to exchange keys or passphrases.  WPA type Setting  Description  Factory Default Personal  Provides Pre-Shared Key-enabled WPA and WPA2  Personal Enterprise Provides enterprise-level security for WPA and WPA2 Encryption method Setting  Description  Factory Default TKIP Temporal Key Integrity Protocol is enabled  TKIP AES  Advance Encryption System is enabled Mixed*  Provides TKIP broadcast key and TKIP+AES unicast key for some legacy AP clients. This option is rarely used.  *This option is available in AP mode only, and cannot support AES-enabled clients. Primary/Secondary RADIUS server IP Setting  Description  Factory Default The IP address of RADIUS server  Specifies the delegated RADIUS server for EAP  None Primary/Secondary RADIUS port Setting  Description  Factory Default Port number  Specifies the port number of the delegated RADIUS server  1812 Primary/ Secondary RADIUS shared key Setting  Description  Factory Default Max. of 31 characters  The secret key shared between AP and RADIUS server  None Key renewal Setting  Description  Factory Default 60 to 86400 seconds (1 minute to 1 year)  Specifies the time period of group key renewal  3600 (seconds)
AirWorks AWK-3121  Web Console Configuration  3-14WPA/WPA2-Enterprise (for Client mode) When used as a client, the AWK-3121 can support three EAP methods (or EAP protocols): EAP-TLS, EAP-TTLS, and EAP-PEAP, corresponding to WPA/WPA-Enterprise settings on the AP side.  Encryption method Setting  Description  Factory Default TKIP Temporal Key Integrity Protocol is enabled  TKIP AES  Advance Encryption System is enabled EAP Protocol Setting  Description  Factory Default TLS  Specifies Transport Layer Security protocol  TLS TTLS  Specifies Tunneled Transport Layer Security PEAP Specifies Protected Extensible Authentication Protocol, or Protected EAP Before choosing the EAP protocol for your WPA/WPA2-Enterpise settings on the client end, please contact the network administrator to make sure the system supports the protocol on the AP end. Detailed information on these three popular EAP protocols is presented in the following sections. EAP-TLS TLS is the standards-based successor to Secure Socket Layer (SSL). It can establish a trusted communication channel over a distrusted network. TLS provides mutual authentication through certificate exchange. EAP-TLS is also secure to use. You are required to submit a digital certificate to the authentication server for validation, but the authentication server must also supply a certificate. You can use Basic Wireless Settings Æ WLAN Certificate Settings to import your WLAN certificate and enable EAP-TLS on the client end.  You can check the current certificate status in Current Status if it is available. • Certificate issued to: Shows the certificate user • Certificate issued by: Shows the certificate issuer • Certificate expiration date: Indicates when the certificate has expired EAP-TTLS It is usually much easier to re-use existing authentication systems, such as a Windows domain or Active Directory, LDAP directory, or Kerberos realm, rather than creating a parallel authentication system. As a result, TTLS (Tunneled TLS) and PEAP (Protected EAP) are used to support the use of so-called “legacy authentication methods.” TTLS and PEAP work in a similar way. First, they establish a TLS tunnel (EAP-TLS for example), and validate whether the network is trustworthy with digital certificates on the authentication server. This step establishes
AirWorks AWK-3121  Web Console Configuration  3-15a tunnel that protects the next step (or “inner” authentication), and consequently is sometimes referred to as “outer” authentication. The TLS tunnel is then used to encrypt an older authentication protocol that authenticates the user for the network. As you can see, digital certificates are still needed for outer authentication in a simplified form. Only a small number of certificates are required, which can be generated by a small certificate authority. Certificate reduction makes TTLS and PEAP much more popular than EAP-TLS. The AWK-3121 provides some non-cryptographic EAP methods, including PAP, CHAP, MS-CHAP, and MS-CHAP-V2. These EAP methods are not recommended for direct use on wireless networks. However, they may be useful as inner authentication methods with TTLS and PEAP. Because the inner and outer authentications can use distinct user names in TTLS and PEAP, you can use an anonymous user name for the outer authentication, with the true user name only shown through the encrypted channel. Keep in mind that not all client software supports anonymous alteration. Confirm this with the network administrator before you enable identity hiding in TTLS and PEAP.  TTL Inner Authentication Setting  Description  Factory Default PAP  Password Authentication Protocol is used  MS-CHAP-V2 CHAP  Challenge Handshake Authentication Protocol is used MS-CHAP  Microsoft CHAP is used MS-CHAP-V2  Microsoft CHAP version 2 is used Anonymous Setting  Description  Factory Default Max. of 31 characters  A distinct name used for outer authentication None User name & Password Setting  Description  Factory Default   User name and password used in inner authentication  None PEAP There are a few differences in the TTLS and PEAP inner authentication procedures. TTLS uses the encrypted channel to exchange attribute-value pairs (AVPs), while PEAP uses the encrypted channel to start a second EAP exchange inside of the tunnel. The AWK-3121 provides MS-CHAP-V2 merely as an EAP method for inner authentication.
AirWorks AWK-3121  Web Console Configuration  3-16Inner EAP protocol Setting  Description  Factory Default MS-CHAP-V2  Microsoft CHAP version 2 is used  MS-CHAP-V2 Anonymous Setting  Description  Factory Default Max. of 31 characters  A distinct name used for outer authentication None User name & Password Setting  Description  Factory Default   User name and password used in inner authentication  None Advanced Wireless Settings Additional wireless-related parameters are presented in this section to help you set up your wireless network in detail.  Transmission Rate Setting  Description  Factory Default Auto  The AWK-3121 senses and adjusts the data rate automatically  Auto Available rates  Users can manually select a target transmission data rate Transmission Power Setting  Description  Factory Default Auto  Specifies wireless signal coverage by automatically selecting the strength of Tx power  Full Full  Equivalent to 0 dBm of maximum Tx power High  Equivalent to -5 dBm of maximum Tx power Medium  Equivalent to -10 dBm of maximum Tx power Low  Equivalent to -15 dBm of maximum Tx power  NOTE  Tx power at “Full” • US model: 17 dBm • EU model: 16 dBm • JP model: 18 dBm
AirWorks AWK-3121  Web Console Configuration  3-17RF type = A (Channel 36 ~ 48) Setting  Description  Factory Default Auto   Specifies wireless signal coverage by automatically selecting the strength of Tx power  Full Full   Equivalent to 0 dBm of maximum Tx power High  Equivalent to -4 dBm of maximum Tx power Medium  Equivalent to -8 dBm of maximum Tx power Low  Equivalent to -12 dBm of maximum Tx power  NOTE  Tx power at “Full” • US model: 14 dBm • EU model: 16 dBm • JP model: 14 dBm  Beacon Interval (for AP mode only) Setting  Description  Factory Default Beacon Interval  (40 to 1000 ms)  Indicates the frequency interval of the beacon  100 (ms) DTIM Interval (for AP mode only) Setting  Description  Factory Default Data Beacon Rate  (1 to 15)  Indicates how often the AWK-3121 sends out a Delivery Traffic Indication Message  1 Fragmentation threshold Setting  Description  Factory Default Fragment Length  (256 to 2346)  Specifies the maximum size a data packet before splitting and creating another new packet  2346 RTS threshold Setting  Description  Factory Default RTS/CTS Threshold (256 to 2346)  Determines how large a packet can be before the Access Point coordinates transmission and reception to ensure efficient communication 2346   NOTE You can refer to the related glossaries in Chapter 5 for detailed information about the above-mentioned settings. By setting these parameters properly, you can better tune the performance of your wireless network.  Transmission distance Setting  Description  Factory Default Distance or max. range for transmission  (500 to 10000 m) Specifies the transmission distance or max. range between two AWK devices. This parameter should be set properly, especially for long-distance communication. 500 Noise protection Setting  Description  Factory Default Enable/Disable  Adjusts the interference coping capability of the wireless signal. This option should be enabled for communication distance under 500 meters, and should be disabled for communication distances over 500 meters. Enable
AirWorks AWK-3121  Web Console Configuration  3-18Transmission enhancement Setting  Description  Factory Default Enable/Disable  This setting can enhance communication by strengthening the AWK-3121’s transmission power. It is quite useful for long-distance transmission or countering environmental interference. The user must carefully evaluate and measure the transmission power of the entire system to ensure it stays below the regulative limit. In addition, that RF type 802.11a mode cannot be used if this function is enabled. Disable  NOTE  When Transmission enhancement is enabled, the Tx Power is at “Full” RF type = B/G/Mixed (Channel1~13) • US model: 22 dBm • EU model: 20 dBm • JP model: 20 dBm RF type = A (Channel 36 ~ 48) • US model: 17 dBm • EU model: 17 dBm • JP model: 17 dBm   NOTE  Make sure the same Transmission distance parameters are set in both AP and Client sides, and both Bridges. When this parameter is greater than 500, an optimal algorithm will be enabled to support long-distance transmission. Note that Transmission enhancement only supports 802.11b/g mode; 802.11a mode is not supported. Transmission enhancement is also recommended to enable communication at both ends when long-distance transmission is required. A high-gain antenna installed at a fixed antenna connector can also improve performance. (Select Antenna at MAIN or AUX.)  Antenna Setting  Description  Factory Default Auto  The AWK-3121 uses two antennas (MAIN and AUX) and enables the diversity function for reducing multipath effect.  Auto MAIN  Diversity function is disabled. Only MAIN antenna is in use. AUX  Diversity function is disabled. Only AUX antenna is in use. EAPOL Version Setting  Description  Factory Default 1  EAPOL version 1 was standardized in the 2001 version of 802.1X, which is much more commonly implemented.  1 2  EAPOL version 2 was specified in 802.1X-2004. WMM Setting  Description  Factory Default Enable/Disable  WMM is a QoS standard for WLAN traffic. Voice and video data will be given priority bandwidth when enabled with WMM supported wireless clients. Disable Full 11a channel support Setting  Description  Factory Default Enable/Disable  “Full 11a channel support” allows users to select one channel from 802.11a, including channels in licensed and unlicensed bands. Disable
AirWorks AWK-3121  Web Console Configuration  3-19 READ THIS BEFORE CHANGING THE DFS SETTING \nDFS (Dynamic Frequency Selection) is a mechanism to allow unlicensed wireless devices to share spectrum with existing radar systems by detecting radar systems and avoid causing interference with them. The current versions of Moxa AWK series products do not support DFS, so only U-NII Low channels (36, 40, 44, and 48) are supported by default. If you want to enable the “Full 11a channel support” option, keep in mind that your wireless devices may interfere with radar systems, which may violate local laws. If you are not sure about this, we recommend that you keep this option disabled. Updated firmware that supports DFS will be available soon.  Turbo Roaming (for Client mode only) Setting  Description  Factory Default Enable/ Disable  Moxa’s Turbo Roaming can enable rapid handover when the AWK-3121, as a client, roams among a group of APs.  Disable When Turbo Roaming is enabled, the RF type, AP alive check, and Scan channels will be shown as follows. RF type shows the current RF type that this client is using. AP alive check will check if the AP connection is still available. When this function is enabled, a check will be done every 10 ms. You can set up Scan channels for the APs among which this client is going to roam. There are three Scan channels available. Note that the Scan channels may need to be modified when the RF type is changed. (For example, channel 36 is not available in B, G, or B/G Mix mode.)  WLAN Certification Settings (for EAP-TLS in Client mode only) When EAP-TLS is used, a WLAN Certificate will be required at the client end to support WPA/WPA2-Enterprise. The AWK-3121 can support the PKCS #12, also known as Personal Information Exchange Syntax Standard, certificate formats that define file formats commonly used to store private keys with accompanying public key certificates, protected with a password-based symmetric key.  Current Status displays information for the current WLAN certificate, which has been imported into the AWK-3121. Nothing will be shown if a certificate is not available. Certificate issued to: Shows the certificate user Certificate issued by: Shows the certificate issuer Certificate expiration date: Indicates when the certificate has expired You can import a new WLAN certificate in Import WLAN Certificate by following these steps, in order: 1. Input the corresponding password (or key) in the Certificate private password field and then click Submit to set the password. 2. The password will be displayed in the Certificate private password field. Click on the Browse button in Select certificate/key file and select the certificate file.
AirWorks AWK-3121  Web Console Configuration  3-203. Click Upload Certificate File to import the certificate file. If the import succeeds, you can see the information uploaded in Current Certificate. If it fails, you may need to return to step 1 to set the password correctly and then import the certificate file again.  NOTE  The WLAN certificate will remain after the AWK-3121 reboots. Even though it is expired, it can still be seen on the Current Certificate.  Advanced Settings Several advanced functions are available to increase the functionality of your AWK-3121 and wireless network system. A VLAN is a collection of clients and hosts grouped together as if they were connected to the broadcast domains in a layer 2 network. The DHCP server helps you deploy wireless clients efficiently. Packet filters provide security mechanisms, such as firewalls, in different network layers. Moreover, the AWK-3121 can support STP/RSTP protocol to increase reliability across the entire network, and SNMP support can make network management easier. Using Virtual LAN Setting up Virtual LANs (VLANs) on your AWK series increases the efficiency of your network by dividing the LAN into logical segments, as opposed to physical segments. In general, VLANs are easier to manage. The Virtual LAN (VLAN) Concept What is a VLAN? A virtual LAN, commonly known as a VLAN, is a group of hosts with a common set of requirements that communicate as if they were attached to the same broadcast domain, regardless of their physical location. A VLAN has the same attributes as a physical LAN, but it allows for end stations to be grouped together even if they are not located on the same network switch. Network reconfiguration can be done through software instead of physically relocating devices.  VLANs now extend as far as the reach of the access point signal. Clients can be segmented into wireless sub-networks via SSID and VLAN assignment. A Client can access the network by connecting to an AP configured to support its assigned SSID/VLAN. Benefits of VLANs VLANs are used to conveniently, efficiently, and easily manage your network in the following ways: • Manage adds, moves, and changes from a single point of contact • Define and monitor groups • Reduce broadcast and multicast traffic to unnecessary destinations • Improve network performance and reduce latency • Increase security • Secure network restricts members to resources on their own VLAN • Clients roam without compromising security
AirWorks AWK-3121  Web Console Configuration  3-21VLAN Workgroups and Traffic Management The AP assigns clients to a VLAN based on a Network Name (SSID). The AP can support up to 9 SSIDs per radio interface, with a unique VLAN configurable per SSID. The AP matches packets transmitted or received to a network name with the associated VLAN. Traffic received by a VLAN is only sent on the wireless interface associated with that same VLAN. This eliminates unnecessary traffic on the wireless LAN, conserving bandwidth and maximizing throughput. In addition to enhancing wireless traffic management, the VLAN-capable AP supports easy assignment of wireless users to workgroups. In a typical scenario, each user VLAN represents a department workgroup; for example, one VLAN could be used for a marketing department and the other for a human resource department. In this scenario, the AP would assign every packet it accepted to a VLAN. Each packet would then be identified as marketing or human resource, depending on which wireless client received it. The AP would insert VLAN headers or “tags” with identifiers into the packets transmitted on the wired backbone to a network switch. Finally, the switch would be configured to route packets from the marketing department to the appropriate corporate resources such as printers and servers. Packets from the human resource department could be restricted to a gateway that allowed access to only the Internet. A member of the human resource department could send and receive e-mail and access the Internet, but would be prevented from accessing servers or hosts on the local corporate network. Configuring Virtual LAN VLAN Settings To configure the AWK’s VLAN, use the VLAN Setting page to configure the ports.  Management VLAN ID Setting  Description  Factory Default VLAN ID ranges from 1 to 4094 Set the management VLAN of this AWK.  1 Port Type  Description  Trunk Port LAN  This port is the LAN port on the AWK.  Yes WLAN  This is a wireless port for the specific SSID. This field will refer to the SSID that you have created. If more SSIDs have been created, new rows will be added.  WDS  This is the WDS port on the AWK  Yes
AirWorks AWK-3121  Web Console Configuration  3-22Port PVID Setting  Description  Factory Default VLAN ID ranging from 1 to 4094  Set the port’s VLAN ID for devices that connect to the port. The port can be a LAN port or WLAN ports.  1 VLAN Tagged Setting  Description  Factory Default A comma-seperated list of VLAN IDs. Each of the VLAN IDs range from 1 to 4094. Specify which VLANs can communicate with this specific VLAN.  (Empty)  NOTE  The VLAN feature can allow wireless clients to manage the AP. If the VLAN Management ID matches a VLAN ID, then those wireless clients who are members of that VLAN will have AP management access. CAUTION: Once a VLAN Management ID is configured and is equivalent to one of the VLAN IDs on the AP, all members of that User VLAN will have management access to the AP. Be careful to restrict VLAN membership to those with legitimate access to the AP.  DHCP Server (for AP mode only) DHCP (Dynamic Host Configuration Protocol) is a networking protocol that allows administrators to assign temporary IP addresses to network computers by “leasing” an IP address to a user for a limited amount of time, instead of assigning permanent IP addresses. The AWK-3121 can act as a simplified DHCP server and easily assign IP addresses to your wireless clients by responding to the DHCP requests from the client ends. The IP-related parameters you set on this page will also be sent to the client. You can also assign a static IP address to a specific client by entering its MAC address. The AWK-3121 provides a Static DHCP mapping list with up to 16 entities. Be reminded to check the Active check box for each entity to activate the setting. You can check the IP assignment status under Status Æ DHCP Client List.  DHCP server (AP only) Setting  Description  Factory Default Enable  Enables AWK-3121 as a DHCP server  Disable Disable  Disable DHCP server function
AirWorks AWK-3121  Web Console Configuration  3-23Default gateway Setting  Description  Factory Default IP address of a default gateway  The IP address of the router that connects to an outside network  None Subnet mask Setting  Description  Factory Default subnet mask  Identifies the type of sub-network (e.g., 255.255.0.0 for a Class B network, or 255.255.255.0 for a Class C network)  None Primary/ Secondary DNS server Setting  Description  Factory Default IP address of Primary/ Secondary DNS server  The IP address of the DNS Server used by your network. After entering the DNS Server’s IP address, you can use URL as well. The Secondary DNS server will be used if the Primary DNS server fails to connect. None Start IP address Setting  Description  Factory Default IP address  Indicates the IP address which AWK-3121 can start assigning  None Maximum number of users Setting  Description  Factory Default 1 – 999  Specifies how many IP address can be assigned continuously  None Client lease time Setting  Description  Factory Default 1 – 10 days  The lease time for which an IP address is assigned. The IP address may go expired after the lease time is reached.   10 (days) Packet Filters The AWK-3121 includes various filters for IP-based packets going through LAN and WLAN interfaces. You can set these filters as a firewall to help enhance network security. MAC Filter The AWK-3121’s MAC filter is a policy-based filter that can allow or filter out IP-based packets with specified MAC addresses. The AWK-3121 provides 8 entities for setting MAC addresses in your filtering policy. Remember to check the Active check box for each entity to activate the setting.  Enable Setting  Description  Factory Default Enable Enables MAC filter  Disable Disable Disables MAC filter
AirWorks AWK-3121  Web Console Configuration  3-24Policy Setting  Description  Factory Default Accept  Only the packets fitting the entities on list can be allowed.  Drop Drop  Any packet fitting the entities on list will be denied.   ATTENTION Be careful when you enable the filter function: Drop + “no entity on list is activated” = all packets are allowed Accept + “no entity on list is activated” = all packets are denied  IP Protocol Filter The AWK-3121’s IP protocol filter is a policy-based filter that can allow or filter out IP-based packets with specified IP protocol and source/destination IP addresses.  The AWK-3121 provides 8 entities for setting IP protocol and source/destination IP addresses in your filtering policy. Four IP protocols are available: All, ICMP, TCP, and UDP. You must specify either the Source IP or the Destination IP. By combining IP addresses and netmasks, you can specify a single IP address or a range of IP addresses to accept or drop. For example, “IP address 192.168.1.1 and netmask 255.255.255.255” refers to the sole IP address 192.168.1.1. “IP address 192.168.1.1 and netmask 255.255.255.0” refers to the range of IP addresses from 192.168.1.1 to 192.168.255. Remember to check the Active check box for each entity to activate the setting.  Enable Setting  Description  Factory Default Enable  Enables IP protocol filter  Disable Disable  Disables IP protocol filter Policy Setting  Description  Factory Default Accept  Only the packets fitting the entities on the list can be allowed  Drop Drop  Any packet fitting the entities on the list will be denied   ATTENTION Be careful when you enable the filter function: Drop + “no entity on list is activated” = all packets are allowed. Accept + “no entity on list is activated” = all packets are denied.  TCP/UDP Port Filter The AWK-3121’s TCP/UDP port filter is a policy-based filter that can allow or filter out TCP/UDP-based packets with a specified source or destination port. The AWK-3121 provides 8 entities for setting the range of source/destination ports of a specific protocol. In addition to selecting TCP or UDP protocol, you can set either the source port, destination port, or both. The end
AirWorks AWK-3121  Web Console Configuration  3-25port can be left empty if only a single port is specified. Of course, the end port cannot be larger then the start port. The Application name is a text string that describes the corresponding entity with up to 31 characters. Remember to check the Active check box for each entity to activate the setting.  Enable Setting  Description  Factory Default Enable  Enables TCP/UDP port filter  Disable Disable  Disables TCP/UDP port filter Policy Setting  Description  Factory Default Accept  Only the packets fitting the entities on list can be allowed.  Drop Drop  Any packet fitting the entities on list will be denied.   ATTENTION Be careful when you enable the filter function: Drop + “no entity on list is activated” = all packets are allowed Accept + “no entity on list is activated” = all packets are denied  RSTP Settings (for AP mode only) AWK-3121 supports IEEE802.1D Spanning Tree Protocol and IEEE802.1w Rapid STP standards. In addition to eliminating unexpected path looping, STP/RSTP can provide a backup path recovery if a wired/ wireless path fails accidentally. The reliability and availability can increase because this fail-over function. AWK-3121’s STP/RSTP feature is disabled by default. To be completely effective, you must enable RSTP/STP on every AWK-3121 connected to your network. If AWK-3121 plays a Client role, which is connected to a device (PLC, RTU, etc.) as opposed to network switch equipment, it is not necessary to enable STP/RSTP. The reason is that it will cause unnecessary negotiation. AWK-3121s support STP/RSTP in AP mode (including WDS) only. The following figures indicate which Spanning Tree Protocol parameters can be configured. A more detailed explanation of each parameter is given below the figure.
AirWorks AWK-3121  Web Console Configuration  3-26RSTP status This field will appear only when selected to operate STP/RSTP. It indicates whether this AWK-3121 is the Root of the Spanning Tree (the root is determined automatically) or not. Bridge priority Setting  Description  Factory Default Numerical value selected by user You can increase the bridge priority by selecting a lower number. A higher bridge priority brings a greater chance of being established as the root of the Spanning Tree topology. 32768 Hello time Setting  Description  Factory Default Numerical value input by user (1 – 10 seconds) The root of the Spanning Tree topology periodically sends out a “hello” message to other devices on the network to check if the topology is healthy. Hello time indicates how often the root sends hello messages. 2 (seconds) Forwarding delay Setting  Description  Factory Default Numerical value input by user (4 – 30 seconds) The amount of time this device waits before checking to see if it should change to a different topology.  15 (seconds) Max. age Setting  Description  Factory Default Numerical value input by user (6 – 40 seconds) As a non-root role, if the device has not received a hello message from the root longer than Max. age, it will reconfigure itself as a root. Once two or more devices on the network are recognized as a root, the devices will renegotiate to set up a new Spanning Tree topology. 20 (seconds) The AWK-3121 comes with 10 “ports” for RSTP settings. Numbers 3-10 (WDS1-WDS8) are available only when WDS is enabled in AP mode.  Enable RSTP Setting  Description  Factory Default Enable/ disable  Enables or disables the port as a node on the Spanning Tree topology.  Disable (unchecked) Port priority Setting  Description  Factory Default Numerical value selected by user  Increase this port’s priority as a node on the Spanning Tree topology by inputting a lower number.  128 Port cost Setting  Description  Factory Default Enable/ Disable  Input a higher cost to indicate that this port is less suitable as a node for the Spanning Tree topology  2000000 Edge port Setting  Description  Factory Default Checked/ unchecked  Sets a port, which no BPDU expectedly goes through, as an edge port  unchecked, except AP port
AirWorks AWK-3121  Web Console Configuration  3-27NOTE  We recommend you set an edge port for the port, which is connected to a non-STP/RSTP sub-network or an end device (PLC, RTU, etc.) as opposed to network equipment. This can prevent unnecessary waiting and negotiation of STP/RSTP protocol, and accelerate system initialization. When an edge port receives BPDUs, it can still function as an STP/RSTP port and start negotiation.  Setting an edge port is different from disabling STP/RSTP on a port. If you disable STP/RSTP, a port will not deal with STP/RSTP BPDUs at all.  Port Status Port Status indicates the current Spanning Tree status of this port. Use Forwarding for normal transmission, or Blocking to block transmission. SNMP Agent The AWK-3121 supports SNMP V1/V2c/V3. SNMP V1 and SNMP V2c use a community string match for authentication, which means that SNMP servers access all objects with read-only or read/write permissions using the community string public/private (default value). SNMP V3, which requires you to select an authentication level of MD5 or SHA, is the most secure protocol. You can also enable data encryption to enhance data security.  The AWK-3121’s MIB can be found in the software CD and supports reading the attributes via SNMP. (Only get method is supported.) SNMP security modes and security levels supported by the AWK-3121 are shown in the following table. Select the security mode and level that will be used to communicate between the SNMP agent and manager. Protocol Version  Setting on UI web page  Authentication Type  Data Encryption  Method SNMP  V1, V2c  V1, V2c Read  Community Community string  No  Use a community string match for authentication V1, V2c Write/Read  Community Community string  No  Use a community string match for authentication SNMP V3  No-Auth  No  No  Use account with admin or user to access objects MD5 or SHA  Authentication based on MD5 or SHA No  Provides authentication based on HMAC-MD5, or HMAC-SHA algorithms. 8-character passwords are the minimum requirement for authentication. MD5 or SHA  Authentication based on MD5 or SHA Data encryption key Provides authentication based on HMAC-MD5 or HMAC-SHA algorithms, and data encryption key. 8-character passwords and a data encryption key are the minimum requirements for authentication and encryption. The following parameters can be configured on the SNMP Agent page. A more detailed explanation of each parameter is given below the following figure.
AirWorks AWK-3121  Web Console Configuration  3-28 Enable Setting  Description  Factory Default Enable Enables SNMP Agent  Disable Disable  Disables SNMP Agent Read community (for V1, V2c) Setting  Description  Factory Default V1, V2c Read Community  Use a community string match with a maximum of 31 characters for authentication. This means that the SNMP agent can access all objects with read-only permissions using this community string. public Write community (for V1, V2c) Setting  Description  Factory Default V1, V2c Read /Write Community  Use a community string match with a maximum of 31 characters for authentication. This means that the SNMP agent can accesses all objects with read/write permissions using this community string. private SNMP agent version Setting  Description  Factory Default V1, V2c, V3, or V1, V2c, or V3 only Select the SNMP protocol version used to manage the switch.  V1, V2c Admin auth type (for V1, V2c, V3, and V3 only) Setting  Description  Factory Default No Auth  Use admin account to access objects. No authentication  No Auth MD5  Provide authentication based on the HMAC-MD5 algorithms. 8-character passwords are the minimum requirement for authentication. SHA  Provides authentication based on  HMAC-SHA algorithms. 8-character passwords are the minimum requirement for authentication. Admin private key (for V1, V2c, V3, and V3 only) Setting  Description  Factory Default Disable No data encryption  Disable DES  DES-based data encryption AES  AES-based data encryption Private key A data encryption key is the minimum requirement for data encryption (maximum of 63 characters) Private MIB Information Device Object ID Also know as OID. This is the AWK-3121’s enterprise value. It is fixed.
AirWorks AWK-3121  Web Console Configuration  3-29Auto Warning Settings Since industrial-grade devices are often located at the endpoints of a system, these devices will not always know what is happening elsewhere on the network. This means that these devices, including wireless APs or clients, must provide system maintainers with real-time alarm messages. Even when system administrators are out of the control room for an extended period, they can still be informed of the status of devices almost instantaneously when exceptions occur. In addition to logging these events, the AWK-3121 supports different approaches to warn engineers automatically, such as SNMP trap, e-mail, and relay output. It also supports two digital inputs to integrate sensors into your system to automate alarms by email and relay output. System Log System Log Event Types Detail information for grouped events is shown in the following table. You can check the box for Enable log to enable the grouped events. All default values are enabled (checked). The log for system events can be seen in Status Æ System Log.  System-related events  Event is triggered when…  System restart (warm start)  The AWK-3121 is rebooted, such as when its settings are changed (IP address, subnet mask, etc.). Network-related events  Event is triggered when…  LAN link on   The LAN port is connected to a device or network.  LAN link off   The port is disconnected (e.g., the cable is pulled out, or the opposing device shuts down).  Client joined/ left  (for AP mode)  A wireless client is associated or disassociated.  WLAN connected to AP (for Client mode)  The AWK-3121 is associated with an AP.  WLAN disconnected (for Client mode)  The AWK-3121 is disassociated from an AP.  Config-related events  Event is triggered when…  Configuration Changed  A configuration item has been changed.  Configuration file import via Web Console The configuration file is imported to the AWK-3121. Console authentication failure   An incorrect password is entered.  Firmware upgraded  The AWK-3121’s firmware is updated. Power events  Event is triggered when…  Power 1/2 transition (On -> Off)   The AWK-3121 is powered down in PWR1/2.  PoE transition (On -> Off)   The AWK-3121 is powered down in PoE.  Power 1/2 transition (Off -> On)  The AWK-3121 is powered via PWR1/2. PoE transition (Off -> On)  The AWK-3121 is powered via PoE.
AirWorks AWK-3121  Web Console Configuration  3-30DI events  Event is triggered when…  DI1/2 transition (On -> Off)  Digital Input 1/2 is triggered by on to off transition DI1/2 transition (Off -> On)  Digital Input 1/2 is triggered by off to on transition Syslog This function provides the event logs for the Syslog server. The function supports up to three configurable Syslog servers and Syslog server UDP port numbers. When an event occurs, the event will be sent as a Syslog UDP packet to the specified Syslog servers. Syslog Event Types Detail information for the grouped events is shown in the following table. You can check the box for Enable log to enable the grouped events. All default values are enabled (checked). Details for each event group can be found on the “System log Event Types” table on page 3-31.  Syslog Server Settings You can configure the parameters for your Syslog servers in this page.  Syslog server 1/ 2/ 3 Setting  Description  Factory Default IP address  Enter the IP address of the 1st/ 2nd/ 3rd Syslog Server  None Syslog port Setting  Description  Factory Default Port destination  (1 to 65535)  Enter the UDP port of the corresponding Syslog server  514 E-mail E-mail Event Types Check the box for Active to enable the event items. All default values are deactivated (unchecked). Details for each event item can be found on the “System log Event Types” table on page 3-31.
AirWorks AWK-3121  Web Console Configuration  3-31 E-mail Server Settings You can set up to 4 e-mail addresses to receive alarm emails from the AWK-3121. The following parameters can be configured on the E-mail Server Settings page. In addition, a Send Test Mail button can be used to test whether the Mail server and e-mail addresses work well. More detailed explanations about these parameters are given after the following figure.  Mail server (SMTP) Setting  Description  Factory Default IP address  The IP Address of your email server.  None User name & Password Setting  Description  Factory Default   User name and password used in the SMTP server  None From e-mail address Setting  Description  Factory Default Max. 63 characters  Enter the administrator’s e-mail address which will be shown in the “From” field of a warning e-mail.  None To E-mail address 1/ 2/ 3/ 4 Setting  Description  Factory Default Max. 63 characters  Enter the receivers’ e-mail addresses.  None
AirWorks AWK-3121  Web Console Configuration  3-32Relay The AWK-3121 has one relay output, which consists of 2 terminal block contacts on the AWK-3121’s top panel. These relay contacts are used to indicate user-configured events and system failure.  The two wires attached to the relay contacts form an open circuit when a user-configured event is triggered. If a user-configured event does not occur, the relay circuit will remain closed. For safety reasons, the relay circuit is kept open when the AWK-3121 is not powered. Relay Event Types You can check the box for Active to enable the event items. All default values are deactivated (unchecked). Details for each event item can be found in the “System log Event Types” table on page 3-31.  Trap Traps can be used to signal abnormal conditions (notifications) to a management station. This trap-driven notification can make your network more efficient. Because a management station usually takes care of a large number of devices that have a large number of objects, it will be overloading for the management station to poll or send requests to query every object on every device. It would be better if the managed device agent could notify the management station by sending a message known as a trap for the event. Trap Event Types
AirWorks AWK-3121  Web Console Configuration  3-33SNMP Trap Receiver Settings SNMP traps are defined in SMIv1 MIBs (SNMPv1) and SMIv2 MIBs (SNMPv2c). The two styles are basically equivalent, and it is possible to convert between the two. You can set the parameters for SNMP trap receivers through the web page.  1st / 2nd Trap version Setting  Description  Factory Default V1  SNMP trap defined in SNMPv1  V1 V2  SNMP trap defined in SNMPv2 1st / 2nd Trap server IP/name Setting  Description  Factory Default IP address or host name  Enter the IP address or name of the trap server used by your network.  None 1st / 2nd Trap community Setting  Description  Factory Default Max. of 31 characters  Use a community string match with a maximum of 31 characters for authentication.  alert Status Associated Client List (for AP mode only) Associated Client List shows all the clients that are currently associated to a particular AWK-3121. You can click Select all to select all the content in the list for further editing. You can click Refresh to refresh the list.
AirWorks AWK-3121  Web Console Configuration  3-34DHCP Client List (for AP mode only) The DHCP Client List shows all the clients that require and have successfully received IP assignments. You can click the Refresh button to refresh the list.  You can press Select all button to select all content in the list for further editing.  System Log Triggered events are recorded in System Log. You can export the log contents to an available viewer by clicking Export Log. You can use the Clear Log button to clear the log contents and the Refresh button to refresh the log.
AirWorks AWK-3121  Web Console Configuration  3-35Relay Status The status of user-configurable events can be found under Relay Status. The status will refresh every 5 seconds if the Auto refresh box is checked.  If an event is triggered, it will be noted on this list. System administrators can click Acknowledge Event when he has acknowledged the event and addressed it.  DI and Power Status The status of power inputs and digital inputs is shown on this web page. The status will refresh every 5 seconds if the Auto refresh box is checked.   Wireless Status The status for 802.11 info parameters, such as Operation mode and Channel, are shown on the Wireless Status page. The status will refresh every 5 seconds if the Auto refresh box is checked.  Certain values for 802.11 info may not show up due to different operation modes. As a result, Current BSSID and Signal strength are not available in AP mode. It is helpful to use the continuously updated information on this page, such as Signal strength, to monitor the signal strength of the AWK-3121 in Client mode.
AirWorks AWK-3121  Web Console Configuration  3-36Maintenance Maintenance functions provide the administrator with tools to manage the AWK-3121 and wired/wireless networks. Console Settings You can enable or disable access permission for the following consoles: HTTP, HTTPS, Telnet and SSH connections. For more security, we recommend you only allow access to the two secured consoles, HTTPS and SSH.  Ping Ping helps to diagnose the integrity of wired or wireless networks. By inputting a node’s IP address in the Destination field, you can use the ping command to make sure it exists and whether or not the access path is available.  If the node and access path are available, you will see that all packets were successfully transmitted with no loss. Otherwise, some, or even all, packets may get lost, as shown in the following figure.  Firmware Upgrade The AWK-3121 can be enhanced with more value-added functions by installing firmware upgrades. The latest firmware is available at Moxa’s download center. Before running a firmware upgrade, make sure the AWK-3121 is off-line. Click the Browse button to specify the firmware image file and click Firmware Upgrade and Restart to start the firmware upgrade. After the progress bar reaches 100%, the AWK-3121 will reboot itself. When upgrading your firmware, the AWK-3121’s other functions are forbidden.
AirWorks AWK-3121  Web Console Configuration  3-37 ATTENTION Please make sure the power source is stable when you upgrade your firmware. An unexpected power breakup may damage your AWK-3121.  Config Import Export You can back up or restore the AWK-3121’s configuration with Config Import Export.  In the Config Import section, click Browse to specify the configuration file and click Config Import button to begin importing the configuration.  In the Config Export section, click the Config Export button and save the configuration file onto your local storage media. The configuration file is a text file and you can view and edit it with a general text-editing tool.   Load Factory Default Use this function to reset the AWK-3121 and roll all settings back to the factory default values. You can also reset the hardware by pressing the reset button on the top panel of the AWK-3121.  Password You can change the administration password for each of the AWK-3121’s console managers by using the Password function. Before you set up a new password, you must input the current password and reenter the new password for confirmation. For your security, do not use the default password root, and remember to change the administration password regularly.
AirWorks AWK-3121  Web Console Configuration  3-38 Misc. Settings Additional settings to help you manage your AWK-3121, are available on this page.  Reset button Setting  Description  Factory Default Always enable  The AWK-3121’s Reset button works normally.  Always enable Disable after 60 sec  The AWK-3121’s reset to default function will be inactive 60 seconds after the AWK-3121 finishes booting up. Save Configuration The following figure shows how the AWK-3121 stores the setting changes into volatile and non-volatile memory. All data stored in volatile memory will disappear when the AWK-3121 is shutdown or rebooted unless they are y. Because the AWK-3121 starts up and initializes with the settings stored in flash memory, all new changes must be saved to flash memory before restarting the AWK-3121. This also means the new changes will not work unless you run either the Save Configuration function or the Restart function.   After you click on Save Configuration in the left menu box, the following screen will appear. Click Save if you wish to update the configuration settings in the flash memory at this time. Alternatively, you may choose to run other functions and put off saving the configuration until later. However, the new setting changes will remain in the non-volatile memory until you save the configurations.
AirWorks AWK-3121  Web Console Configuration  3-39 Restart If you submitted configuration changes, you will find a blinking string in the upper right corner of the screen. After making all your changes, click the Restart function in the left menu box. One of two different screens will appear. If you made changes recently but did not save, you will be given two options. Clicking the Restart button here will reboot the AWK-3121 directly, and all setting changes will be ignored. Clicking the Save and Restart button will apply all setting changes and then reboot the AWK-3121.  If you run the Restart function without changing any configurations or saving all your changes, you will see just one Restart button on your screen.  You will not be able to run any of the AWK-3121’s functions while the system is rebooting. Logout Logout helps users disconnect the current HTTP or HTTPS session and go to the Login page. For security reasons, we recommend you logout before quitting the console manager.
  4  4. Software Installation and Configuration The following topics are covered in this chapter:  Overview  AWK Search Utility ¾ Installing AWK Search Utility ¾ Configuring AWK Search Utility
AirWorks AWK-3121  Software Installation and Configuration  4-2Overview The Documentation & Software CD included with your AWK-3121 is designed to make the installation and configuration procedure easy and straightforward. This auto-run CD includes AWK Search Utility (to broadcast search for all AWK’s accessible over the network), the AWK-3121 User’s Manual, and Quick Installation Guide. AWK Search Utility Installing AWK Search Utility Click the INSTALL UTILITY button in the AWK Installation CD auto-run window to install AWK Search Utility. Once the program starts running, click Yes to proceed. 1. Click Next when the Welcome screen opens to proceed with the installation.  2. Click Next to install program files to the default directory, or click Browse to select an alternate location.
AirWorks AWK-3121  Software Installation and Configuration  4-33. Click Next to create the program’s shortcut files to the default directory, or click Browse to select an alternate location.  4. Click Next to select additional tasks.  5. Click Next to proceed with the installation. The installer then displays a summary of the installation options.  6. Click Install to begin the installation. The setup window will report the progress of the installation. To change the installation settings, click Back and navigate to the previous screen.
AirWorks AWK-3121  Software Installation and Configuration  4-47. Click Finish to complete the installation of AWK Search Utility.  Configuring AWK Search Utility The Broadcast Search function is used to locate all AWK-3121 APs that are connected to the same LAN as your computer. After locating an AWK-3121, you will be able to change its IP address. Since the Broadcast Search function searches by TCP packet and not IP address, it doesn’t matter if the AWK-3121 is configured as an AP or Client. In either case, APs and Clients connected to the LAN will be located, regardless of whether or not they are part of the same subnet as the host. 1. Start the AWK Search Utility program. When the Login page appears, select the “Search AWK only” option to search for AWKs and to view each AWK’s configuration. Select the “AWK management” option to assign IPs, upgrade firmware, and locate devices.  2. Open the AWK Search Utility and then click the Search icon.
AirWorks AWK-3121  Software Installation and Configuration  4-53. The “Searching” window indicates the progress of the search. When the search is complete, all AWKs that were located will be displayed in the AWK Search Utility window.  4. Click Locate to cause the selected device to beep.  5. Make sure your AWK is unlocked before using the search utility’s icons setting. The AWK will unlock automatically if the password is set to the default. Otherwise you must enter the new password manually.  6. Go to Tools Æ AWK login Options to manage and unlock additional AWKs.  7. Use the scroll down list to select the MAC addresses of those AWKs you would like to manage, and then click Add. Key in the password for the AWK device and then click OK to save. If you return to the search page and search for the AWK again, you will find that the AWK will unlock automatically.
AirWorks AWK-3121  Software Installation and Configuration  4-6 ATTENTION For security purposes, we suggest you can change the AWK search utility login password instead of using the default.   To modify the configuration of the highlighted AWK, click on the Web icon to open the web console. This will take you to the web console, where you can make all configuration changes. Refer to Chapter 3, “Using the Web Console,” for information on how to use the web console.  Click on Telnet if you would like to use telnet to configure your AWKs.
AirWorks AWK-3121  Software Installation and Configuration  4-7Click Assign IP to change the IP setting.  The three advanced options—Search, Connection, and Miscellaneous—are explained below: Search • Retry count (default=5): Indicates how many times the search will be retried automatically. • Retry interval (ms): The time lapsed between retries.  Connection • Connection timeout (secs): Use this option to set the waiting time for the Default Login, Locate, Assign IP, Upload Firmware, and Unlock to complete. • Upgrade timeout (secs): Use this option to set the waiting time for the connection to disconnect while the firmware is upgrading. Use this option to set the waiting time for the Firmware to write to flash.
AirWorks AWK-3121  Software Installation and Configuration  4-8Misc. Search on start: Checkmark this box if you would like the search function to start searching for devices after you log in to the AWK search Utility.
  5  5. Other Console Considerations This chapter explains how to access the AWK-3121 for the first time. In addition to HTTP access, there are four ways to access AWK-3121: serial console, Telnet console, SSH console, and HTTPS console. The serial console connection method, which requires using a short serial cable to connect the AWK-3121 to a PC’s COM port, can be used if you do not know the AWK-3121’s IP address. The other consoles can be used to access the AWK-3121 over an Ethernet LAN, or over the Internet. The following topics are covered in this chapter:  RS-232 Console Configuration (115200, None, 8, 1, VT100)  Configuration by Telnet and SSH Consoles  Configuration by Web Browser with HTTPS/SSL  Disabling Telnet and Browser Access
AirWorks AWK-3121  Other Console Considerations  5-2RS-232 Console Configuration (115200, None, 8, 1, VT100) The serial console connection method, which requires using a short serial cable to connect the AWK-3121 to a PC’s COM port, can be used if you do not know the AWK-3121’s IP address. It is also convenient to use serial console configurations when you cannot access the AWK-3121 over Ethernet LAN, such as in the case of LAN cable disconnections or broadcast storming over the LAN.  ATTENTION Do not use the RS-232 console manager when the AWK-3121 is powered at reversed voltage (ex. -48VDC), even though reverse voltage protection is supported. If you need to connect the RS-232 console at reversed voltage, Moxa’s TCC-82 isolator is your best solution.   NOTE  We recommend using Moxa PComm (Lite) Terminal Emulator, which can be downloaded free of charge from Moxa’s website.  Before running PComm Terminal Emulator, use an RJ45 to DB9-F (or RJ45 to DB25-F) cable to connect the AWK-3121’s RS-232 console port to your PC’s COM port (generally COM1 or COM2, depending on how your system is set up). After installing PComm Terminal Emulator, take the following steps to access the RS-232 console utility. 1. From the Windows desktop, open the Start menu and start PComm Terminal Emulator in the PComm (Lite) group. 2. Select Open under Port Manager to open a new connection.  3. The Communication Parameter page of the Property window opens. Select the appropriate COM port for Console Connection, 115200 for Baud Rate, 8 for Data Bits, None for Parity, and 1 for Stop Bits. Click on the Terminal tab, and select VT100 (or ANSI) for Terminal Type. Click on OK to continue.
AirWorks AWK-3121  Other Console Considerations  5-34. The Console login screen will appear. Log into the RS-232 console with the login name (default: admin) and password (default: root, if no new password is set).  5. The AWK-3121’s device information and Main Menu will be displayed. Please follow the description on screen and select the administration option you wish to perform.   NOTE  To modify the appearance of the PComm Terminal Emulator window, select Edit Æ Font and then choose the desired formatting options.    ATTENTION If you unplug the RS-232 cable or trigger DTR, a disconnection event will be evoked to enforce logout for network security. You will need to log in again to resume operation.  Configuration by Telnet and SSH Consoles You may use Telnet or SSH client to access the AWK-3121 and manage the console over a network. To access the AWK-3121’s functions over the network from a PC host that is connected to the same LAN as the AWK-3121, you need to make sure that the PC host and the AWK-3121 are on the same logical subnet. To do this, check your PC host’s IP address and subnet mask. NOTE  The AWK-3121’s default IP address is 192.168.127.253 and the default subnet mask is 255.255.255.0 (for a Class C network). If you do not set these values properly, please check the network settings of your PC host and then change the IP address to 192.168.127.xxx and subnet mask to 255.255.255.0.  Follow the steps below to access the console utility via Telnet or SSH client.
AirWorks AWK-3121  Other Console Considerations  5-41. From Windows Desktop, run Start Æ Run, and then use Telnet to access the AWK-3121’s IP address from the Windows Run window (you may also issue the telnet command from the MS-DOS prompt).  2. When using SSH client (ex. PuTTY), please run the client program (ex. putty.exe) and then input the AWK-3121’s IP address, specifying 22 for the SSH connection port.  3. The Console login screen will appear. Please refer to the previous paragraph “RS-232 Console Configuration” and for login and administration. Configuration by Web Browser with HTTPS/SSL To secure your HTTP access, the AWK-3121 supports HTTPS/SSL encryption for all HTTP traffic. Perform the following steps to access the AWK-3121’s web browser interface via HTTPS/SSL. 1. Open your web browser and type https://<AWK-3121’s IP address> in the address field. Press Enter to establish the connection.  2. Warning messages will pop out to warn users that the security certificate was issued by a company they have not chosen to trust.
AirWorks AWK-3121  Other Console Considerations  5-53. Select Yes to accept the certificate issued by Moxa IW and then enter the AWK-3121’s web browser interface secured via HTTPS/SSL. (You can see the protocol in URL is https.) Then you can use the menu tree on the left side of the window to open the function pages to access each of AWK-3121’s functions.  Disabling Telnet and Browser Access If you are connecting the AWK-3121 to a public network but do not intend to use its management functions over the network, then we suggest disabling both Telnet Console and Web Configuration. Please run Maintenance Æ Console Settings to disable them, as shown in the following figure.
  A  A. References This chapter provides more detailed information about wireless-related technologies. The information in this chapter can help you administer your AWK-3121s and plan your industrial wireless network better. The following topics are covered in this appendix:  Wireless Distribution System (WDS)  Beacon  DTIM  Fragment  RTS Threshold  STP and RSTP ¾ The STP/RSTP Concept ¾ Differences between RSTP and STP
AirWorks AWK-3121  References  A-2Wireless Distribution System (WDS)  Traditionally, APs are connected via Ethernet LAN ports. By using a Wireless Distribution System (WDS), APs can communicate with one another wirelessly. For example, AP 2 acts as an access point for the notebook computers or other IEEE802.11-enabled clients, and forwards packets sent from the notebook computers to AP 1 through WDS. Then, AP 1 forwards the packets to the Ethernet LAN. Packets destined for the notebook computers follow a reverse path from the Ethernet LAN through the APs to the notebook computers. In this way, AP 2 acts as an “AP repeater.”  By using WDS, two or more LAN segments can be connected wirelessly. As illustrated in the above figure, a pair of wireless LAN-to-LAN bridges is used to connect two LAN segments. Since the AP is WDS-enabled, it can be used as a wireless bridge.  It is a good idea to plan your wireless network by drawing a diagram so that you know how each AWK-3121 is connected to other peer APs or wireless bridges by WDS, and how bridges are connected to other peer bridges by WDS. See the following figure for an example of a network-planning diagram.
AirWorks AWK-3121  References  A-3 ATTENTION Be sure to eliminate loops from networks that consist of wireless bridges, Ethernet switches, Ethernet links, and WDS links. If any loops exist, packets will circle around the loops and network performance will be seriously degraded. The following figure shows a network topology containing a loop.   Beacon A beacon is a packet broadcast by the AP to keep the network synchronized. A beacon includes the wireless LAN service area, the AP address, the Broadcast destination address, a time stamp, Delivery Traffic Indicator Maps (DTIM), and the Traffic Indicator Message (TIM). Beacon Interval indicates the frequency interval of AP.  DTIM Delivery Traffic Indication Map (DTIM) is contained in beacon frames. It is used to indicate that broadcast and multicast frames buffered by the AP will be delivered shortly. Lower settings result in more efficient networking, while preventing your PC from dropping into power-saving sleep mode. Higher settings allow your PC to enter sleep mode, thus saving power. Fragment A lower setting means smaller packets, which will create more packets for each transmission. If you have decreased this value and experience high packet error rates, you can increase it again, but it will likely decrease overall network performance. Only minor modifications of this value are recommended. RTS Threshold RTS Threshold (256-2346) – This setting determines how large a packet can be before the Access Point coordinates transmission and reception to ensure efficient communication. This value should remain at its default setting of 2,346. When you encounter inconsistent data flow, only minor modifications are recommended.
AirWorks AWK-3121  References  A-4STP and RSTP The STP/RSTP Concept Spanning Tree Protocol (STP) was designed to help reduce link failures in a network, and provide protection from loops. Networks that have a complicated architecture are prone to broadcast storms caused by unintended loops in the network. The STP protocol is part of the IEEE802.1D standard, 1998 Edition bridge specification.  Rapid Spanning Tree Protocol (RSTP) implements the Spanning Tree Algorithm and Protocol defined by IEEE802.1w-2001 standard. RSTP provides the following benefits: • The topology of a bridged network will be determined much more quickly compared to STP. • RSTP is backward compatible with STP, making it relatively easy to deploy. For example: ¾ Defaults to sending 802.1D-style BPDUs if packets with this format are received. ¾ STP (802.1D) and RSTP (802.1w) can operate on the LAN ports and WLAN ports (AP and WDS1-WDS8) of the same AWK-3121. This feature is particularly helpful when the AWK-3121 connects to older equipment, such as legacy switches. Differences between RSTP and STP RSTP is similar to STP, but includes additional information in the BPDUs that allow each bridge to confirm that it has taken action to prevent loops from forming when it decides to enable a link to a neighboring bridge. Adjacent bridges connected via point-to-point links will be able to enable a link without waiting to ensure that all other bridges in the network have had time to react to the change. The main benefit of RSTP is that the configuration decision is made locally rather than network-wide, allowing RSTP to carry out automatic configuration and restore a link faster than STP.
  B  B. Supporting Information This chapter presents additional information about this manual and product. You can also learn how to contact Moxa for technical support. The following topics are covered in this appendix:  About This User’s Manual  DoC (Declaration of Conformity) ¾ Federal Communication Commission Interference Statement ¾ R&TTE Compliance Statement  Firmware Recovery
AirWorks AWK-3121  Supporting Information  B-2About This User’s Manual This manual is mainly designed for, but nto limited to, the following hardware and firmware for the AWK-3121: • Hardware Rev:   1.1 • Firmware Ver:  1.1 You are strongly recommended to visit Moxa’s website (http://www.moxa.com) and find the latest product datasheet, firmware, QIG (Quick Installation Guide), UM (User’s Manual) and related information.  NOTE You can find out the hardware revision number of AWK-3121 on the side label.   The firmware version number can be seen on the Overview page, as follow:   DoC (Declaration of Conformity) Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
AirWorks AWK-3121  Supporting Information  B-3• Consult the dealer or an experienced radio/TV technician for help. FCC Caution: To assure continued compliance, (example – use only shielded interface cables when connecting to computer or peripheral devices). Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. This transmitter must not be co-located or operated in conjunction with any other antenna or transmitter. FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator & your body. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC 15.407(e): Within the 5.15-5.25 GHz band, U-NII devices will be restricted to indoor operations to reduce any potential for harmful interference to co-channel MSS operations. NOTE  The availability of some specific channels and / or operational frequency bands are country dependent and are firmware programmed at the factory to match the intended destination. The firmware setting is not accessible by the end user.  R&TTE Compliance Statement Moxa declares that the apparatus AWK-3121 complies with the essential requirements and other relevant provisions of Directive 1999/5/EC. This equipment complies with all the requirements of DIRECTIVE 1999/5/CE OF THE EUROPEAN PARLIAMENT AND THE COUNCIL OF 9 March 1999 on radio equipment and telecommunication terminal equipment and the mutual recognition of their conformity (R&TTE). The R&TTE Directive repeals and replaces in the directive 98/13/EEC (Telecommunications Terminal Equipment and Satellite Earth Station Equipment) as of April 8, 2000. Safety This equipment is designed with the utmost care for the safety of those who install and use it. However, special attention must be paid to the dangers of electric shock and static electricity when working with electrical equipment. All guidelines of this and of the computer manufacturer must therefore be allowed at all times to ensure the safe use of the equipment. EU Countries Intended for Use The ETSI version of this device is intended for home and office use in Austria, Belgium, Denmark, Finland, France (with Frequency channel restrictions), Germany, Greece, Ireland, Italy, Luxembourg, Portugal, Spain, Sweden, The Netherlands, and United Kingdom. The ETSI version of this device is also authorized for use in EFTA member states Norway and Switzerland. EU Countries Not Intended for Use None. Potential Restrictive Use France: only channels 10, 11, 12, and 13.
AirWorks AWK-3121  Supporting Information  B-4Firmware Recovery When the LEDs of FAULT, Signal Strength, CLIENT, BRIDGE and WLAN all light up simultaneously and blink at one-second interval, it means the system booting has failed. It may result from some wrong operation or uncontrollable issues, such as an unexpected shutdown during firmware update. The AWK-3121 is designed to help administrators recover such damage and resume system operation rapidly. You can refer to the following instructions to recover the firmware: Connect to the AWK-3121’s ES-232 console with 115200bps and N-8-1. You will see the following message shown on the terminal emulator every one second.  Press Ctrl - C and the following message will appear.  Enter 2 to change the network setting. Specify where the AWK-3121’s firmware file on the TFTP server and press y to write the settings into flash memory.   AWK-3121 restarts, and the “Press Ctrl-C to enter Firmware Recovery Process…” message will reappear. Press Ctrl-C to enter the menu and select 1 to start the firmware upgrade process.  Select 0 in the sub-menu to load the firmware image via LAN, and then enter the file name of the firmware to start the firmware recovery.

Navigation menu