Moxa ZB-PM3-T Sub-1G communication module User Manual Sub 1G

Moxa Inc. Sub-1G communication module Sub 1G

User Manual_rev.pdf

Moxa Industrial Sub-1G Module ZB-DCU3-T, ZB-PM3-T, ZB-WAN1-T User’s Manual  First Edition, August 2014  www.moxa.com/product                          © 2014 Moxa Inc. All rights reserved. Reproduction without permission is prohibited.
Moxa Industrial Sub-1G Module ZB-DCU3-T, ZB-PM3-T, ZB-WAN1-T User’s Manual The software described in this manual is furnished under a license agreement and may be used only in accordance with the terms of that agreement.  Copyright Notice © 2014 Moxa Inc. All rights reserved.  Trademarks The MOXA logo is a registered trademark of Moxa Inc. All other trademarks or registered marks in this manual belong to their respective manufacturers.  Disclaimer Information in this document is subject to change without notice and does not represent a commitment on the part of Moxa. Moxa provides this document as is, without warranty of any kind, either expressed or implied, including, but not limited to, its particular purpose. Moxa reserves the right to make improvements and/or changes to this manual, or to the products and/or the programs described in this manual, at any time. Information provided in this manual is intended to be accurate and reliable. However, Moxa assumes no responsibility for its use, or for any infringements on the rights of third parties that may result from its use. This product might include unintentional technical or typographical errors. Changes are periodically made to the information herein to correct such errors, and these changes are incorporated into new editions of the publication.  Technical Support Contact Information www.moxa.com/support Moxa Americas                Moxa China (Shanghai office) Toll-free: 1-888-669-2872            Toll-free: 800-820-5036 Tel: +1-714-528-6777              Tel: +86-21-5258-9955 Fax: +1-714-528-6778             Fax: +86-21-5258-5505  Moxa Europe                Moxa Asia-Pacific Tel: +49-89-3 70 03 99-0            Tel: +886-2-8919-1230 Fax: +49-89-3 70 03 99-99            Fax: +886-2-8919-1231
Table of Contents 1. Introduction ........................................................................................................ 1-1 Overview .................................................................................... 1-2 Features ..................................................................................... 1-2 Specifications ............................................................................ 1-2 2. Getting Started .............................................................................................. 2-1 Module Layout ............................................................................ 2-2 Block Diagram ............................................................ 2-2 Connector Locations ................................................................. 2-3 Hardware Installation ............................................................. 2-3 Software Installation ........................................................... 2-3 A. Regulatory Statements............................................................................. A-1
1 1. Introduction The following topics are covered in this chapter:   Overview   Features   Specifications
Overview Moxa Sub-1G module(ZB-DCU3-T, ZB-PM3-T, ZB-WAN1-T) uses ATMEL wireless microcontroller which provides a comprehensive solution with large memory(256KB Flash and 16KB SRAM), high CPU and radio performance and all RF components included.  The module is a range of ultra low power, high performance surface mount modules targeted at Sub-1G networking applications, enabling users to realize products with minimum time to market and at the lowest cost. Sub-1G module(ZB-DCU3-T, ZB-PM3-T, ZB-WAN1-T) can implement networking stacks, such as ZigBee, as well as customer applications  Note: * The Sub-1G module will implement into Moxa System’s DCU and CFE/Protecsa’s Smart Meter application. So, it should follow Moxa System’s DCU-8620-T specification and CFE/Protecsa AMI specification that provided by CFE company.  Features • Support SCM setting • Support upgrade firmware over the AIR • Support AES-128 compatible encryption • Support large packets fragmentation • Support Mesh topology  Specifications Sub-1G Interface Internal Memory: 256KB     Flash : 256KB. SRAM: 16KB RF Standard: IEEE 802.15.4 Frequency Band: 769 ~ 935 MHz RF Data Rate: 20 ~ 40 Kbps (BPSK modulation) RF Channel: 10 channel Tx Power: +10 dBm Rx sensitivity: -110 dBm Distance: 900M Serial Communication Parameters UART Baud Rate: 50 bps to 115.2K Kbps Power Requirement Power consumption: RX:26 mA        TX:110 mA Operating Supply Voltage: 3.3 V
Environmental Limits   Operating Temperature: -40 to 75°C (-40 to 167°F)   Operating Humidity: 5 to 95% RH   Storage Temperature: -40 to 85°C (-40 to 185°F) Physical Characteristics Dimension: ZB-DCU3-T/ZB-WAN1-T (48x30x1.6mm), ZB-PM3-T (45x38x1.6mm) Standard and Certifications EMC: CE (EN55022 and EN55024 Class A), FCC Part 15 Subpart B Class A Reliability   Automatic Reboot Trigger: Built-in WDT (watchdog timer)   MTBF (meantime between failures): Over 10 years   Warranty   Warranty Period: 5 years   Details: See www.moxa.com/warranty
2 2. Getting Started This chapter covers the module layout, and block diagram, hardware installation of the Sub-1G module. Software installation is covered in the next chapter.   Module Layout   Block Diagram   Connector Locations   Hardware Installation   Software Installation
Module Layout ZB-DCU3-T, ZB-WAN1-T +  ZB-PM3-T +  Block Diagram       =   =
PIN Define ZB-DCU3-T, ZB-WAN1-T PIN Number PIN Function PIN Number PIN Function 1  3.3V  2  3.3V 3  GND  4  GND 5  GND  6  GND 7  NC  8  NC 9  NC  10  NC 11  RXD  12  NC 13  TXD  14  NC 15  NC  16  NC 17  NC  18  NC 19  NC  20  RESET  ZB-PM3-T PIN Number PIN Function 1  VCC 2  TXD 3  RXD 4 RST 5 NC 6 GND 7 GND   Hardware Installation The Sub-1G Module can be installed into Moxa DCU-8620-T Embedded Computer system and Power Meter.  Steps for Installation on DCU 1. Attach the WLAN antenna to connector UI. 2. Let Sub-1G Module(ZB-DCU3-T and ZB-WAN1-T) connect to DCU-8620-T. 3. Screw on the Sub-1G Module  Steps for Installation on Power Meter 1. Let Sub-1G Module(ZB-PM3-T) connect to Power Meter. 2. Recover the Power Meter.
Software Installation After physically installing the Sub-1G module, the module will be recognized on the new system board after the following steps.  Steps for Installation 1. Apply power to the system board. 2. Run DCU-8620-T application program. Make sure it could communicate with Sub-1G module(ZB-WAN1-T and ZB-DCU3-T). 3. Apply power to the Power Meter. Make sure the LED of “Ready” light-on on Power Meter. 4. Run DCU-8620-T application program, make sure it could read data from Power Meter through the air.
A A. Regulatory Statements Federal Communication Commission Interference Statement  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two  conditions:  (1)  This  device  may  not  cause  harmful  interference, and  (2)  this  device must accept any interference received, including interference that  may cause undesired operation.  This equipment has been tested and found to comply with the limits for a Class B digital device,  pursuant  to  Part  15  of  the  FCC  Rules.    These  limits  are  designed  to  provide reasonable  protection  against  harmful  interference  in  a  residential  installation.  This equipment  generates,  uses  and  can  radiate  radio  frequency  energy  and,  if  not  installed and  used  in  accordance  with  the  instructions,  may  cause  harmful  interference  to  radio communications.    However,  there  is  no  guarantee  that  interference  will  not  occur  in  a particular  installation.    If  this  equipment  does  cause  harmful  interference  to  radio  or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:  -  Reorient or relocate the receiving antenna. -  Increase the separation between the equipment and receiver. -  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -  Consult the dealer or an experienced radio/TV technician for help.  FCC  Caution:  Any  changes  or  modifications  not  expressly  approved  by  the  party responsible for compliance could void the user's authority to operate this equipment.  This  transmitter  must  not  be  co-located  or  operating  in  conjunction  with  any  other antenna or transmitter.
   Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.  This  equipment  should  be  installed  and  operated  with  minimum  distance 20cm between the radiator & your body.   This device is intended only for OEM integrators under the following conditions:  1) The antenna must be installed such that 20 cm is maintained between the antenna and users, and   2) The transmitter module may not be co-located with any other transmitter or antenna.  As long as 2 conditions above are met, further transmitter test will not be required. However, the OEM integrator is still responsible for testing their end-product for any additional compliance requirements required with this module installed  IMPORTANT NOTE: In the event that these conditions can not be met (for example certain laptop configurations or co-location with another transmitter), then the FCC authorization is no longer considered valid and the FCC ID can not be used on the final product. In these circumstances, the OEM integrator will be responsible for re-evaluating the end product (including the transmitter) and obtaining a separate FCC authorization.  End Product Labeling   This transmitter module is authorized only for use in device where the antenna may be installed such that 20 cm may be maintained between the antenna and users. The final end product must be labeled in a visible area with the following: “Contains FCC ID: SLE-ZB-PM3-T” or “Contains FCC ID: SLE-ZB-DCU3-T”. The grantee's FCC ID can be used only when all FCC compliance requirements are met.  Manual Information To the End User The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module in the user’s manual of the end product which integrates this module. The end user manual shall include all required regulatory information/warning as show in this manual.