Murandi Communications MLINK900 FREQUENCY HOPPING TRANSCEIVER WITH GPS User Manual Murandi Letterhead
Murandi Communications Ltd FREQUENCY HOPPING TRANSCEIVER WITH GPS Murandi Letterhead
User Manual
Murandi Communications Ltd. Innovative Radio Frequency Solutions MLink User’s Guide Revision – Rev 5 May 14, 2014 Murandi Communications Ltd. 106, 4715 - 13th St. NE, Calgary, Alberta, Canada, T2E 6M3 Tel: (403) 777-9988 email murandi@murandi.com Fax: (403) 777-9989 www.murandi.com Confidential and Proprietary User’s Guide Page 2 5/14/2014 10:30 PM Table of Contents LEGAL DISCLAIMER AND CONDITIONS OF USE ............................................................... 2 REVISION HISTORY ............................................................................................................... 3 ABBREVIATIONS .................................................................................................................... 3 REFERENCE DOCUMENTS .................................................................................................. 4 PRODUCT OVERVIEW ........................................................................................................... 4 FEATURES .............................................................................................................................. 4 SPECIFICATIONS ................................................................................................................... 4 7.1 7.2 7.3 7.4 7.5 7.6 PHYSICAL............................................................................................................................ 4 ELECTRICAL ........................................................................................................................ 4 DATA RATES ....................................................................................................................... 5 INTERFACES ........................................................................................................................ 5 FIRMWARE .......................................................................................................................... 5 ENVIRONMENTAL ................................................................................................................. 5 REGULATORY CERTIFICATION ........................................................................................... 5 8.1 UNITED STATES (FCC) ........................................................................................................ 5 8.1.1 Labeling Requirements ................................................................................................ 5 8.1.2 FCC Notices ................................................................................................................ 6 8.2 CANADA (IC) ....................................................................................................................... 6 8.3 APPROVED ANTENNAS ......................................................................................................... 7 INTEGRATION INSTRUCTIONS ............................................................................................ 9 9.1 MOUNTING .......................................................................................................................... 9 9.2 INTERFACES ........................................................................................................................ 9 9.2.1 900 MHz and GPS Antenna ........................................................................................ 9 9.2.2 900 MHz and GPS RF connector .............................................................................. 10 9.2.3 Digital/Baseband ........................................................................................................ 10 Legal Disclaimer and Conditions of Use This document contains information for the Murandi MLink 900 Transceiver and accompanying accessories (“Product”) and is provided “as is”. The purpose of providing such information is to enable a Product Developer to understand the Product and how to integrate it into a wireless data solution. Reasonable effort has been made to make the information in this document reliable and consistent with specifications, test measurements and other information. However, Murandi Communications Ltd. and its affiliated companies, directors, officers, employees, agents, trustees or consultants (“Murandi”) assume no responsibility for any typographical, technical, content or other inaccuracies in this document. Murandi reserves the right in its sole discretion and without notice to you to change Product specifications and materials and/or revise this document or withdraw it at any time. The Product Developer assumes the full risk of using the Product specifications and any other information provided. Your use of the information contained in this Guide is restricted to the development activity authorized under the agreement(s) between you and Murandi, and is otherwise subject to all applicable terms and conditions of such agreement(s), including without limitation software license, warranty, conditions of use and confidentiality provisions. Murandi Communications Ltd. 106, 4715 - 13th St. NE, Calgary, Alberta, Canada, T2E 6M3 Tel: (403) 777-9988 email murandi@murandi.com Fax: (403) 777-9989 www.murandi.com Confidential and Proprietary User’s Guide Page 3 5/14/2014 10:30 PM Revision History Revision Draft Rev 1 Rev 2 Rev 3 Date Feb 10, 2014 Feb 27, 2014 May 2, 2014 May 11, 2014 Rev 4 Rev 5 May 12, 2014 May 14, 2014 Description Initial release Added integration instructions Grammatical & text clean up Added coaxial cable specifications for use with Yagi Antenna Updated the requirements for the external antenna. Updated the integration instructions. Abbreviations Abbreviation Attn BW dB dBc dBi dBm FCC FHSS GPS IC ISM ISR kHz LCD LED LNA mA mcd MHz mm msec mV PA PLL ppm RBW RF RTC TBC TBD TRP μA TDD UART Description attenuator bandwidth decibel decibel relative to carrier power decibel relative to an isotropic antenna decibel relative to 1 milliwatt federal communications commission frequency hopping spread spectrum global positioning system Industry Canada industrial, scientific and medical interrupt service routine kilohertz liquid crystal display light emitting diode low noise amplifier milliampere millicandle mega-hertz millimeter millisecond millivolt power amplifier phase locked loop parts per million resolution bandwidth radio frequency Real time clock to be confirmed to be determined total radiated power microampere Time division duplex universal asynchronous receiver/transmitter volts width Murandi Communications Ltd. 106, 4715 - 13th St. NE, Calgary, Alberta, Canada, T2E 6M3 Tel: (403) 777-9988 email murandi@murandi.com Fax: (403) 777-9989 www.murandi.com Confidential and Proprietary User’s Guide Page 4 5/14/2014 10:30 PM Reference Documents 1. MLink Block Diagrams – Draft, Feb 10, 2014 2. Schematics (MLINK – Rev 3.pdf) 3. Bill of Materials (MLINK – Rev 3.bom) Product Overview MLink 900 is an ultra energy and cost efficient, long range wireless network. Available as a module, development platform or a fully customized product. Perfect for a wide range of applications, this highly versatile platform enables rapid design, development, and deployment of your next generation products. Features Ultra Low Energy: Up to 10 years or more from AA batteries or even directly from the sun. Impressive Range: Up to 10 km or more using high efficiency integral antennas. Design Flexibility: Build your application right on the MLink platform or communicate through the embedded serial port. Integrated GPS Direct support for a variety of peripherals: Displays, accelerometers Industrial sensors, audio alerts Intrinsically safe options available. Specifications 7.1 GPS Physical RF Deck Size (including antennas) 56 x 64 x 15.25 mm Digital Power Supply Custom GPS Antenna Custom 900 MHz Antenna Peripheral Interface 7.2 Electrical Frequency Range 902 – 928 MHz (US/Can) Output Power up to +29 dBm (US/Can) Effective Radiated Sensitivity better than -120 dBm (1.2 kbps at 10-3 BER) Access Method TDD - FHSS Batteries // Solar Cell Murandi Communications Ltd. LED LCD Acceler ometer Speaker Serial Interface Buttons 106, 4715 - 13th St. NE, Calgary, Alberta, Canada, T2E 6M3 Tel: (403) 777-9988 email murandi@murandi.com Fax: (403) 777-9989 www.murandi.com Confidential and Proprietary User’s Guide DC Supply Voltage Energy Consumption (typical @ 38.4 kpbs) 7.3 Page 5 5/14/2014 10:30 PM 2.2 to 3.3 Vdc o TX < 20 mJ o RX < 0.5 mJ o GPS update < 150 mJ typ o Standby (/s) < 50 µW Data Rates Dynamically adaptable from 1.2 – 38.4 kbps Up to 76.8 kbps optional 7.4 Interfaces RF o 50 Ω Radio/GPS Digital/Base Band o ADC, PWM, GPIO, I2C, SPI, UART o 40 pin edge connector 7.5 Firmware Real Time Operating System Embedded, autonomous protocol Up to 64 kB Flash and 4 kB RAM available for customer applications 7.6 Environmental Operating Temperature -40 to +65 C Storage Temperature -40 to +65 C Operating Relative Humidity 0 to 90% non-condensing Regulatory Certification 8.1 United States (FCC) MLink 900 module meets Part 15 of the FCC rules and regulations. Compliance with the labeling requirements, FCC notices is required. In order to comply with FCC Certification requirements, the Original Equipment Manufacturer (OEM) must fulfill the following requirements. 1. The system integrator must place an exterior label on the outside of the final product housing the MLink 900 Module. Figure 8.1.1.1 below shows the contents that must be included in this label. 2. MLink 900 modules may only be used with the antenna that has been tested and approved for use with the module. 3. NOTE: THE MURANDI COMMUNICATIONS LTD IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT. 8.1.1 Labeling Requirements The OEM must make sure that FCC labeling requirements are met. This includes a clearly visible exterior label on the outside of the final product housing that displays the contents shown in Figure 8.1.1.1 below. Murandi Communications Ltd. 106, 4715 - 13th St. NE, Calgary, Alberta, Canada, T2E 6M3 Tel: (403) 777-9988 email murandi@murandi.com Fax: (403) 777-9989 www.murandi.com Confidential and Proprietary User’s Guide Page 6 5/14/2014 10:30 PM Manufacturer’s name Brand name or Trade Name Contains MLink 900 FCC ID: KQNMLINK900 IC ID: 2361A-MLINK900 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Figure 8.1.1.1 – FCC Label 8.1.2 FCC Notices WARNING: The MLink 900 modules have been tested by the FCC for use with other products without further certification (as per FCC Section 2.1091). Changes or modifications to this device not expressly approved by Murandi Communications could void the user’s authority to operate the equipment. NOTICE: OEM’s must verify the final end product complies with unintentional radiators (FCC Section 15.107 and 15.109) before providing a declaration of conformity for their final product to Part 15 of the FCC Rules. NOTICE: The MLink 900 modules have been certified for mobile and fixed radio applications. If the module will be used for portable applications, the device must undergo SAR testing. RF Exposure WARNING: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. NOTICE: The preceding statement must be included as a CAUTION statement in OEM product manuals in order to alert users of FCC RF Exposure compliance. 8.2 Canada (IC) This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Murandi Communications Ltd. 106, 4715 - 13th St. NE, Calgary, Alberta, Canada, T2E 6M3 Tel: (403) 777-9988 email murandi@murandi.com Fax: (403) 777-9989 www.murandi.com Confidential and Proprietary User’s Guide Page 7 5/14/2014 10:30 PM Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante. This radio transmitter Model: MLink 900, IC: 2361A–MLINK900 has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Le présent émetteur radio Model: MLink 900, IC: 2361A – MLINK900 a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés ci-dessous et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur. 8.3 Approved Antennas MLink 900 modules are approved for mobile and fixed applications. FCC & IC requires that for mobile applications the antenna be mounted a minimum of 20 cm from users, as captured in section 8.1.2 above. MLink 900 modules has been approved for use with both an integral antenna and recommended external antenna captured below including a 1.2 dB min cable loss. External antenna types with the same or lower maximum gain are permitted for use with MLink 900. Professional installation is required for the external antenna. Manufacturer Part Number Type Gain Application MaxStream Inc or Laird Technologies A09-Y8NF or PC904 Element Yagi 4.8 dBd Mobile and Fixed Min Separation 20 cm Note 1: Including 1.2 dB min cable loss as captured below: 5 ft min of RG-174 (27.9 dB/100 ft @ 900 MHz) 7 ft min of RG-58/RG-8X (20.1 dB/100 ft @ 900 MHz) 16 ft min of RG-213/LMR240 (7.7 dB/100 ft @ 900 MHz) 32 ft min of LMR-400 (3.9 dB/100 ft @ 900 MHz) Murandi Communications Ltd. 106, 4715 - 13th St. NE, Calgary, Alberta, Canada, T2E 6M3 Tel: (403) 777-9988 email murandi@murandi.com Fax: (403) 777-9989 www.murandi.com Confidential and Proprietary User’s Guide Page 8 5/14/2014 10:30 PM Note 2: With 1.2 dB min cable loss (as captured below) for 4.8 dBd total. Note 3: With 1.2 dB min cable loss (as captured below) for 7 dBi total. 5 ft min of RG-174 (27.9 dB/100 ft @ 900 MHz) 7 ft min of RG-58/RG-8X (20.1 dB/100 ft @ 900 MHz) 16 ft min of RG-213/LMR240 (7.7 dB/100 ft @ 900 MHz) 32 ft min of LMR-400 (3.9 dB/100 ft @ 900 MHz) Murandi Communications Ltd. 106, 4715 - 13th St. NE, Calgary, Alberta, Canada, T2E 6M3 Tel: (403) 777-9988 email murandi@murandi.com Fax: (403) 777-9989 www.murandi.com Confidential and Proprietary User’s Guide Page 9 5/14/2014 10:30 PM Integration Instructions MLink 900 is designed for use in countless wireless applications requiring long range communications with low energy consumption. To ensure that the final product complies with the all of the regulatory requirements for the Modular Grant the following integration instructions should be followed. MLink is limited to OEM installation ONLY. The OEM integrator is responsible for ensuring that the end-user has no manual instructions to remove or install the module. 9.1 Mounting Two mounting holes are provided as shown in the figure below. In addition MLink incorporates an edge connector which mates with a Samtec MEC1-120-02-S-D-A connector. These can be used to securely mount MLink in the final product. Mounting Hole Mounting Hole Edge Connector Figure 9.1.1 – MLink 900 Mechanical Drawing 9.2 Interfaces There are three interfaces on the MLink 900 modules - 900 MHz Antenna/RF, GPS Antenna/RF and Digital/Baseband. 9.2.1 900 MHz and GPS Antenna For the MLink 900A modules integral 900 MHz and GPS antennas are incorporated. These antennas have been design to handle a wide variety of environments. To minimize degradation in the performance of the antennas it is recommended that non metallic, low dielectric constant, Murandi Communications Ltd. 106, 4715 - 13th St. NE, Calgary, Alberta, Canada, T2E 6M3 Tel: (403) 777-9988 email murandi@murandi.com Fax: (403) 777-9989 www.murandi.com Confidential and Proprietary User’s Guide Page 10 5/14/2014 10:30 PM low dielectric loss materials such as the housing ideally be 0.25” or greater from the antennas (as showing in figure 9.1.1). Note: As per section 8.1.2 a minimum 8” (20 cm) separation must be maintained between the 900 MHz antenna and the user to ensure compliance with the MPE regulatory requirements. Otherwise additional regulatory approval may be required for the final product. 9.2.2 900 MHz and GPS RF connector For the MLink 900C modules RF connections to both the 900 MHz and GPS are provided to permit external antennas to be used which can be mounted remotely from MLink: 900 MHz Impedance: 50 Ω Connector: MMCX female jack 1,2 Antenna: See section 8.1.3 Note 1: Similar antennas with the same or lower gain may be used. Note 2: As per section 8.1.2 a minimum 20 cm separation must be maintain between the 900 MHz antenna and the user to ensure compliance with the MPE regulatory requirements. Otherwise additional regulatory approval may be required for the final product. Professional installation is required for the external antenna. GPS 50 Ω MMCX female jack Active GPS antenna with built in LNA 3V 50 mA max Impedance: Connector: Antenna: DC Power: 9.2.3 Digital/Baseband MLink 900 incorporates a standard edge connector which mates with a Samtec MEC1-120-02-SD-A connector in the final product. Power and standard digital interfaces to LED’s, Buzzers, Sensors are provided. Many of the interface pins are reconfigurable and a list of key pins are Pin # 39 Name Vcc (input) 31, 32 Ground (bi-directional) 10, 12 UART1 (bi-directional) UART2 (bi-directional) P1PPs (output) 21, 23 18 Description Power Supply Main power supply for MLink Typically provided by two AA, C, or D cell batteries 2.2 to 3.3 Vdc 500 mA max current draw Ground Low impedance ground connection for MLink power supply, digital and analog signals. Digital (see note 1) GPS serial interface Digital (see note 1) MLink serial interface GPS 1pps Murandi Communications Ltd. 106, 4715 - 13th St. NE, Calgary, Alberta, Canada, T2E 6M3 Tel: (403) 777-9988 email murandi@murandi.com Fax: (403) 777-9989 www.murandi.com Confidential and Proprietary User’s Guide Page 11 Pin # 8, 10, 12, 26, 22, 28, 30, 34 Name Digital I/O (bi-directional) Analog Input (input) Note 1: 5/14/2014 10:30 PM Description Digital (see note 1) General purpose digital I/O which is firmware configurable – for example for use with LED, Buttons Analog A/D used to sample analog voltage – i.e. sensor output. 0 to 1.5 V 10 kohms min input impedance Digital levels for operation. Input: @ VDD = 2.2 V, max low level 1.0 V. @ VDD = 3.3 V, max low level 1.65 V. @ VDD = 2.2 V, min high level 1.2 V. @ VDD = 3.3 V, min high level 1.8 V. Min input impedance 20k Max input capacitance 10 pF Output: @ VDD = 2.2 V, max low level 0.25 V. @ VDD = 3.3 V, max low level 0.25 V. @ VDD = 2.2 V, min high level 1.95 V. @ VDD = 3.3 V, min high level 3.05 V. Max output impedance 500 Max output capacitance 10 pF For additional information please contact Murandi Communications at 403-777-9988 or technical.support@murandi.com. Murandi Communications Ltd. 106, 4715 - 13th St. NE, Calgary, Alberta, Canada, T2E 6M3 Tel: (403) 777-9988 email murandi@murandi.com Fax: (403) 777-9989 www.murandi.com Confidential and Proprietary
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 11 Language : en-US Tagged PDF : Yes Title : Murandi Letterhead Author : Super Dave Creator : Microsoft® Office Word 2007 Create Date : 2014:05:15 04:30:46 Modify Date : 2014:05:15 04:30:46 Producer : Microsoft® Office Word 2007EXIF Metadata provided by EXIF.tools