Murphy Digital Tach Hourmeter With Overspeed Trip Point Shd30 Users Manual SHD3 97050B Art NEW
SHD30 to the manual ca4f35b7-ae95-487e-902d-58c88692009d
2015-02-05
: Murphy Murphy-Digital-Tach-Hourmeter-With-Overspeed-Trip-Point-Shd30-Users-Manual-396872 murphy-digital-tach-hourmeter-with-overspeed-trip-point-shd30-users-manual-396872 murphy pdf
Open the PDF directly: View PDF .
Page Count: 2
■
Normally Open and Normally Closed Overspeed
Alarm or Shutdown Switch (Standard)
■
RPM Data and Power Supplied by Magnetic
Pickup or Capacitor Discharge (CD) Ignition
■
Accurate to ±0.5% of Display Reading
■
Hours Can Be Preset and Reset to Zero
■
Approved for Class I, Division 2,
Groups C & D Hazardous Areas
SHD30 and SHD30-45 Models
Description
The SHD30 and SHD30-45 are microprocessor-
based tachometers with hourmeter and an over-
speed trip point. The trip point can be connected
as either a form “c ” relay output or as a normally
open SCR output for alarm or shutdown on over-
speed.
The SHD30 features a panel-mounting design, plas-
tic enclosure that is 5-1/16 (129 mm) long and
4-1/4 in. (108 mm) high.
The SHD30-45 has the same enclosure, but it also
has a backplate with studs to mount like a SHD-
45, OPLFC.
The SHD30 models power and RPM data are
supplied by either a magnetic pickup or a capacitor
discharge (CD) ignition. The hourmeter is
adjustable to a preset time and resettable to zero.
Should power be lost, on-board batteries maintain
the run hours display and allow for resetting the
overspeed relay output.
Basic Operation
When a tach signal is present the SHD30 models
display rpm. When a tach signal is not present, the
display is blank unless the Read Hours membrane
key, on the faceplate is pressed and held.
The five-digit, liquid crystal display is updated every
second. The run hours, overspeed set point and
current pulses per engine revolution can be dis-
played by manipulating the membrane switches.
Run hours can be displayed even after power is
lost. The run hours display can be configured to
alternate with the RPM display.
Applications
Easy-to-Calibrate
The SHD30 models calibration is done by enter-
ing the number of pulses per engine revolution
using the Pulses per Revolution and Overspeed
Setpoint membrane keys, on the faceplate. The
number of pulses is determined by the number of
cylinders, cycles and ignition features. It is also
determined by the number of ring gear teeth of
the engine’s flywheel on a magnetic pickup sys-
tem.
Presetting and resetting running hours is done from
the back and front of the SHD30 models.
Specifications
Power input:
CD ignition: 90 to 350 VDC.
150 µA typical @ 90 VDC;
300 µA @ 350 VDC.
Magnetic Pickup: 5 to 120 Vrms.
325 µA typical @ 5 Vrms, 100 Hz;
450 µA typical @ 5 Vrms, 1 kHz;
1 mA typical @ 5 Vrms, 5 kHz;
2 mA typical @ 5 Vrms, 10 kHz;
15 mW max. @ 5 Vrms, 10 kHz;
2.8 W max. @ 120 Vrms, 10 kHz.
Backup Batteries: 2 replaceable, long life
Lithium batteries, Panasonic CR2032 or
equivalent, 3 V, 220 mAh power. Shelf life
expectancy 10 years.
Operating Temperature:
-4° to 158°F (-20° to 70°C).
Storage Temperature:
-40° to 300°F (-40° to 150°C).
Case Material: Plastic.
Ignition Frequency Range: 3 to 666 Hz.
Magnetic Pickup Frequency Range: 1 to 10 kHz.
Overspeed Output:
Connected to S.C.R. (Silicon Controlled
Rectifier) terminals:
0.5 A, 350 VDC continuous.
Connected to Form “C” Relay terminals:
Relay Contact, 0.5 A, 30 VDC, 125 VAC resistive.
Tachometer Accuracy: ±0.5% of the display
reading or ±1 RPM whichever is greater.
Hourmeter Range: 0 to 65535 hrs.
Hourmeter Accuracy: ±15 minutes per year.
Laboratory Approvals: CSA (Canadian
Standards Association) approved for Class I,
Division 2, Groups C & D hazardous areas.
Shipping Weight : 1 lb ( 0.5 kg).
Shipping Dimensions: 9-1/4 x 8-1/4 x 5-1/4 in.
(235 x 210 x 133 mm).
•
Gas Compressors
•
Oil Field Equipment
•
Industrial Engines
•
Generators
When installed per Murphy Drawing 20-08-0258
C US
SHD3-97050B
Revised 07-04
Replaces SHD-95064B
Catalog Section 20
(00-02-0287)
Digital Tachometer and Hourmeter
with Adjustable Overspeed Trip Point
Typical Wiring Diagram
SHD-30 Model Dimensions
Front View Side View
SHD-30-45 Model Dimensions
panel
4-1/4 in.
(108 mm)
5-1/16 in.
(129 mm)
1-9/32 in.
(33 mm)
2 in.
(51 mm)
2 in.
(51 mm)
1-1/2 in.
(38 mm)
2 in.
(51 mm)
3/16 in
(5 mm)
diameter,
4 places
3-1/8 in.
(79 mm)
diameter
CD Ignition
90-350VDC
+
—
5-120Vrms
IGN
Shield
ground
Magnetic Pickup
5 - 120Vrms OR
C. N.C.
+
+
–
–
N.O.
1234
1234
567
TB1
TB2
TB2
1 NO
2 C
3 NC
4 +Overspeed SCR
5 –Overspeed SCR
6 Reset Hourmeter
7
TB1
1 MPU +
2 MPU –
3 NEG 90-300vdc
4 POS 90-300vdc
5-120Vrms
Mounting Hole
How to Order
Specify model number:
SHD30
= Tach/hourmeter w/overspeed
SHD30-45
= Tach/hourmeter w/overspeed to
mount like SHD45 or OPLFC
00-00-9389
= Panasonic CR2032 or equivalent
backup battery (2 required)
WARNING: In hazardous areas the overspeed relay contact
is certified for use ONLY with Murphy non-incendive or intrin-
sically safe products. In non-hazardous areas overspeed relay
contact may be used to switch electromechanical Tattletale® or Magnetic
Switches that do not exceed the relay contact rating: 1 A, 30 VDC; 0.3 A,
110 VDC; 0.5 A, 125 VAC. However, the preferred output to switch
electromechanical Tattletale® or Magnetic Switches is the N.O. SCR.
Refer to SHD3-97051N for more details.
SHD3-97050B page 2 of 2
SCR = 0.5A,
A,
300Vd
Vd
c
CD IGN 90-300Vd
Vd
c TYP:
YP:
150uA
A
@
@
90Vd
Vd
c; 600uA @
@
300Vd
Vd
c
MPU
PU
5Va
Va
c-120Vac TYP
YP
: 325uA
A
@ 5Vac,100Hz; 450uA@
A@
5Va
Va
c 1kHz;
15mw MAX
X
@ 5Vac,10kHz; 2.8W MAX
AX
@
@
120Va
Va
c, 10kHz
INSTALLE CONFORMEMENT MURPHY 20-08-0258
MUST BE INSTALLED PER MURPHY DWG. 20-08-0258
1mA
A
@
@
5Va
Va
c,5kHz; 2mA
A
@ 5Vac,10kHz;
OUTPUT REL
EL
AY
AY
= 0.5A, 30Vd
Vd
c, 125Vd
Vd
c res
4-1/4 in.
(108 mm)
5-1/16 in.
(129 mm)
5-13/16 in.
(148 mm )
1-5/16 in.
(33 mm )
1/2 in.
(12 mm )
KEPS Nuts
(3 Supplied)
Ø6-1/2 in.
5-13/16 in.
(148 mm )
Ø5-13/64 in.
1/4 in. (6 mm ) dia. holes
(3 places)
Front View
Rear View
Side View
Warranty
A limited warranty on materials and workmanship is given with this
FW Murphy product. A copy of the warranty may be viewed or printed
by going to www.fwmurphy.com/support/warranty.htm
CONTROL SYSTEMS & SERVICES DIVISION
P.O. Box 1819; Rosenberg, Texas 77471; USA
+1 281 633 4500 fax +1 281 633 4588
e-mail sales@fwmurphy.com
MURPHY DE MEXICO, S.A. DE C.V.
Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje
San Luis Potosí, S.L.P.; México 78384
+52 444 8206264 fax +52 444 8206336
Villahermosa Office +52 993 3162117
e-mail ventas@murphymex.com.mx
www.murphymex.com.mx
FRANK W. MURPHY, LTD.
Church Rd.; Laverstock, Salisbury SP1 1QZ; U.K.
+44 1722 410055 fax +44 1722 410088
e-mail sales@fwmurphy.co.uk
www.fwmurphy.co.uk
MURPHY SWITCH OF CALIFORNIA
41343 12th Street West
Palmdale, California 93551-1442; USA
+1 661 272 4700 fax +1 661 947 7570
e-mail sales@murphyswitch.com
www.murphyswitch.com
In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.
MACQUARRIE CORPORATION
1620 Hume Highway
Campbellfield, Vic 3061; Australia
+61 3 9358 5555 fax +61 3 9358 5558
e-mail murphy@macquarrie.com.au
FW Murphy
P.O. Box 470248
Tulsa, Oklahoma 74147 USA
+1 918 317 4100
fax +1 918 317 4266
e-mail sales@fwmurphy.com
www.fwmurphy.com
R
E
G
I
S
T
E
R
E
D
USA–ISO 9001:2000 FM 28221
UK–ISO 9001:2000 FM 29422
Printed in U.S.A.