NEC of America 5828 NEC NLite L 28 X DS1 5.8 GHz Digital Microwave Radio User Manual Part 4
NEC Corporation of America NEC NLite L 28 X DS1 5.8 GHz Digital Microwave Radio Part 4
Contents
User Manual Part 4
ROI-506301 SETTING, CONTROL AND MONITORING WITH LCT Chart 5-4 Set Provisioning Daia icont‘d) Step Procedure —- Pm! 11mm I , 7 , '7’|'i.1.Wbtas_(Ci-i1 fi-z t37~fl I-4. 3Mbps(CH1-02) l ‘ lltg mbpucnwtn r l | us 12Mbps(CH1»07 J t - Ib-,EMDELCHTfl),;.J | .s. 30Mbps(CH1-20) . L9: fiMbrzgtcHLZzit, , 7 , J Current Setting : 2 Enter SeIeDIion ([RE11=No Change) : 1 Notes: "‘I For 8*l.5M at Main/Main *2 For 8*1.5M/For16*I.5MathJiri/Main *3 For16*l.5M/Fnr 28‘1.5M at Main/Main ‘4 For Z8*].5M Throughput for Main signal is selectable at Main Shared according to Main signal inlerface. -- Paultmomwtw , mumps (cm) *172L"3j ‘4, 3Mbps (CH1~02) | ‘ lI‘5. GMbps (cm-04) ‘ l l ‘.6. 12Mbps(CH1-08] lbs »f21MbFflCHTiEF;J,J | , 30Mbps(CH1-20) . L9: AZMbfilQHL2§>_ _ _ . J Current Setting : 2 Enter Selection ([RET]:N0 Change) : 1 Nines: *I For 8"I.5M at Main Shared "‘2 Fur 16*l.5M 01 Main Shared "‘3 Far 28*I.5M a! Main Shared When Pnrtl throughput is 1.5Mbps, following Framing format selection appears, Pom 1.5M Framing Format ,_ 1. UP (Unframed) 2. SF (ANSI T1107) 3. ESF (ANSI T1107) Current Setting : 2 Enter Selection ([RET]=No Change) : 1 5-25 SETTING, CONTROL AND MONITORING WITH LCT ROI—506301 Chart 5-4 Set Provisioning Data (Cont’dl Step Procedure When Portl/Pnrlz Assignment is set to SC Shared, WS Shared or Main Shared, following Port switching selection appears, -— Port Swltcning -— 1. Enable 2. Disable Current Setting : 2 Enter Selection ([RET]=NO Change) I 1 11 Press the “l" or “2" key and press the “Enter" key, Port1 Setting 1. Auto Negotiation (AUTO-MDI/MDIX) 2. 10BASE-T / Half Duplex (MDI) 3v 108ASE»T / Half Duplex (MDIXl 4.1OBASE-T / Full Duplex (MDI) 5.1OBASE-T 1 Full Duplex (MDIX) GA 1DOBASE-TX / Half Duplex (MDI) 7. WOEASETX / Full Duplex (MDIX) a. 100BASE-TX 1 Half Duplex (MDI) 9. 1OOBASE-TX / Full Duplex (MDIX) Current Setting : 1 Enter Selection([RETI=No Change): 3 12 Enter corresponding Port] interface mode number and press lhe “Enter" key, v-- Portt Collision Report --- 1 Enable 2 Disable Current Setting: 1 EnterSelection([RE‘fl=No Change): 2 Pnrtl Collision Report selection is displayed when the "Aulo Negotiation (AulO MDl / MDlX)" or "*“** / Half Duplex (****)" is selected in Port] Setting. 13 Press the “I " or “2" key and press the “Enter“ key, 5-26 ROI-808301 SETTING, CONTROL AND MONITORING WITH LCT Chart 54 Set Provisioning Data (Cont'd) Step Procedure --- Pom Flow Conlml -» 1. Enable 2. Disable Current Setting : 1 Enter Selection([RET]=No Change)‘ 1 14 Press the “l” or “2” key and press the “Enter" key, ——- Pom Far End Link Down Conlrol -—- 1. Enabled 2. Disabled Current Selling : 1 Enter Selemion([RET]=No Change): 2 Note.“ N01 displayed when I’m'l wing is" “Er/able 15 Press the “l“ or “2“ key and press the “Enter” key, When LAN PorlZ is used, continue lhe selling as follows, —- Portz Throughput —» 1. S4kbps 2. 128kbps Current Sening ; 2 Enter Selecllon ([RET]=N0 Change) : 1 When P0112 is assigned to 1.5Mhps Main signal. xhroughput for Mam signal is selectable at Main/SC according to Main s|gnal inicrface. When PortZ throughpul is 1.5Mbps, following Framing format selection appears, —- P0112 1.5M Framing Formal 1. UF (Unframed) 2. SF (ANSI T1.107) 3. ESF (ANSI T1.107) Current Sailing : 2 Enter Selection ([RET]=N0 Change) : 1 16 Press Ihe “2" key for “Sel Provisioning Data" and press the “Enler” key (refer to Step 1), 5-27 SETTING, CONTROL AND MONITORlNG WITH LCT Relsoesm Chan 5-4 Set Provisioning Data (Cont’d) Step Procedure 17 Press the “1" key for “Main/LAN Signal Configuration” and press the "Enter“ key, -— LAN (Main / ws 1 SC) function -- 1. Used 2. Not Used Current Setting : 1 Enter Selection ([RET]:N0 Change) : z 18 Press the “1” key and press the “Enter“ key when LAN is not provided, — Port2 Setting -. 1. Auto Negotiation (AUTO-MDI/MDIX) 2. 10BASE»T / Halt Duplex (MDI) 3. lflfiAsE-T / Halt Duplex (MDIX) 4. loBASEvT I Full Duplex (MDI) 5.1OBASE»T / Full Duplex (MDIX) S. 100BASE-TX / Hall Duplex (MDI) 7, 1OOBASE-TX / Full Duplex (MDlX) B, 1ODBASE-TX / Half Duplex (MDI) 9. 1OOBASE»TX I Full Duplex (MDIX) Current Setting : 1 Enter Selection([RET]=No Change): a 19 Enter corresponding P0rt2 interface mode number and press the “Enter" key, ._ Port2 Collision Report -— 1. Enable 2. Disable Current Setting : 1 Enter Selection([RET]=No Change): 2 P0rl2 Collision Report selection is displayed when Ihe "Auto Negotiation (Auto MD] / MDIX)" or "MM / Half Duplex (****)" is selected in Port] Setting. 20 Press the “l” or “2" key and press the “Enter" key, 5-28 ROI~806301 SETTING, CONTROL AND MONITORING WITH LCT Chart 5-4 Set Provisioning Data (Cont’d) Step Procedure -— Port2 Flow Confiol — 1. Enable 2. Disable Curran! Semng : 1 Enter Seleclion([RET]=No Change)’ 2 21 Press lhe “l” or “2" key and press the “Enter" key, -»~ P0rl2 Far End Link Down Control --- 1. Enabled 2 Disabled Currenl Setting : 1 Enter SelectionflRETFNo Change). 2 Nola: Nat drxplrlyed when Port wing is “Enable", 22 Press the “l" or “2" key and press the “Enter" key, —- Main Inlertace Setting _- --- CH01 Usage -—- 1. Used 2. Not Used Current Setting : 1 Enter Selection ([RE'|'J = No Change) : The main channel signal lo be used is selected from the following items. Used: When lhe 1.5 Mbps signal is applied, select Ihe “Used" in corresponding channel. Not Used: When the 1.5 Mbps signal is not applied, select the “Not Used” in corresponding channel. 23 Press the “l" or “2" key and press the “Enter” key, —-- CHOZ Usage --- 1, Used 2. Not Used Current Setting : 1 Enter Selection ([RET] = No Change) : 24 Press the “l" or “2" key and press Ihe “Euler“ key, 5-29 SETTING, CONTROL AND MONlTORING W|TH LCT Rotsnssm Chart 5-4 Set Provisioning Data (Cont‘d) Step Procedure —- CH03 Usage --- 1. Used 2. Not Used Current Setting : 1 Enter Selectiun (mm = No Change) : 25 Press the “l" or “2” key and press the “Enter" key, --- CH04 Usage —- 1. Used 2. Not Used Current Setting : 1 Enter Selection ([RET] = No Change) : 26 Press the “l" or “2“ key and press the “Enter" key, —- CHO1-04 Bipolar Code Select -— 1. AMI Z 3828 Current Setting : 1 Enter Selecfion (lRETj = No Change) : 27 Press the “1 " or “2" key and press the “Enter" key, ~> CHM—04 Line Length Select - 1. 0-133tt( 0- 40m) 2. 133 - ZESft ( 40 » 81m) 3. 266 . 391m ( 31 . 121m) A 399 . 533ft (121 . 162m) 5. 533 . 655ft (162 . 199m) Current Setting : 1 EnterSelection (IRETj = No Change) : z 28 Enter item number for corresponding Line Lengh and press the “Enter” key, Set AMI or B8ZS and line length for each 4 CH block. 5-30 ROI—506301 SETTING, CONTROL AND MONITORING WITH LCT Chart 54 Set Provisioning Data (Cont’d) Step Procedure For 45 MB 3 stem 29 Press the “1“ key on the Set Provisioning Data menu for the Main/LAN Signal configuration and press the “Enter“ key, —- LAN (Main I ws 1 so) iunciion -— 1, Used 2, Not Used Currenl Setting : 2 Enter Selection (IRETFNO Change) : 1 30 Press the “1” key and press the “Enter” when LAN is provided, -- LAN Interface Setting -- —- Pam/Ponz Assignment -— 1. SC NA 2. WS N 3 Main NA, 4. SC SC 5, SC WSW,” '1 6. Main 50 7. Main WS" & Main / Main. 9, SC shared 10. W3 Shared. 11, Main Shared ‘1 Euler Selection : 6 Note: *1,~ displayed only when optional WS is provided, 31 Enter Ihe item number for the signal assignment and press the “Enter" key, When Port] is assigned to SC/NA, SC/WS or Por|l+P0r12 to SC Shared, the throilghpul for SC signal is selectable from either 64kbps or l28kbps. When SC/NA SC/WS —- Pom Throughput- 1, (54ka 2s 128kbps Current Sening : 1 Enter Selection ([RET]:N0 Change) : z 5-31 SETTING, CONTROL AND MONITORING WITH LCT ROI-806301 Chart 5-4 Set Provisioning Dam (Cont’dj Step Procedure When WS is used, throughput for WS signal is fixed in 1.5Mbps., then, following Framing Format selection appears, Pom lsm Framing Formal 1. UP (Unlramed) 2. SF (ANSI film 3. ESF (ANSI 71.107) Current Setting : 2 Enter Selection ([RET]=N0 Change) J 1 When Main is used, throughput for Main signal in Port] is fixed in 44Mbps. 32 Press the “1". “2" or “3" key and press the “Enter” key or press only “Enter” key [or no change, —- Pom Selling —- 1. Auto Negotiation (AUTO-MDI/MDIX) 2.1OBASE-T 1 Half Duplex (MDI) 3. 1OBASE-T Hall Duplex (MDIX) 44 1OBASE-T Full Duplex (MD!) 5. 10BASE-T Full Duplex (MDIX) 6. 1OOBASE-TX 7, 1ODEASE»TX 8. 100BASE-TX 9. 1005ASE-TX Current Setting : 1 Enter Selection([RE'|1=No Change): 4 Hall Duplex (mm) Full Duplex (MDIX) Halt Duplex (MDI) Full Duplex (MDIX) 33 Enter item number which is corresponding Port] interface mode and press the “Enter" key, 5-32 ROI»506301 SETTING, CONTROL AND MONITORING WITH LCT Chart 5-4 Set Provisioning Data lCont’d) Step Procedure —- Pom Collision Report -— 1. Enable 2. Disable Current Selling : 1 Enter Selection([RETj=No Change)‘ 2 Port! Collision Report selection is displayed when the "Auto Negotiation (Auto MDl / MDlX)" or ""‘*"" / Half Duplex (****)" is selected in Port] Setting. 34 Press the “1" or “2” key and press the “Enter“ key, —- Pom Flow Control 1. Enable 2. Disable Current Setting : 1 Enter Selection([RET]=No Change)‘ 2 35 Press the “1” or “2“ key and press the “Enter” key, —-- Porfl Far End Link Down Conlrol —- 1, Enabled 2. Disabled Current Setting : 1 Enter SelectionuREn=No Change): 2 Nate: Nol displayed when Paw selling is “Enable " Press the “l" or “2" key and press the “Enter” key, When LAN Pan2 is used. continue the setting for Ford as follows, Purl2 Throughput m 1 64kbps 2. 128kbps Currenl Setting : 2 Enler Selection ([RET]=N0 Change) : 1 When P0112 is assigned to 1.5Mbps Main signal, throughput for Main signal is selectable at Main/SC according to Main signal interface, 5-33 SETTING, CONTROL AND MONITORING WITH LCT ROI-806301 544 Char! 5-4 Set Provi oning Dara (Cont‘d) Step Procedure When PortZ throughput is LSMbps (WS Used), following Framing formal selection appears, —- Pofl2 1.5M Framing Format --- 1. ur (Unframed) 2. SF (ANSI T1107) 3. ESF (ANSI 71,107) Current Setting : 2 Enter Selection ([RET]=No Change) : 1 -—- Pon2 Setting -- 1. Aulo Negotiation (AUTQMDI/MDIX) 2.1OEASE-T I Hall Duplex (MDI) 3.1OBASE-T / Hal! Duplex (MDIX) 4u105ASE-T 1 Full Duplex (MDI) 5.1OBASE-T I Full Duplex (MDIX) er 1OOBASE»TX / Half Duplex (MDI) 7.1ooBASE-Tx I Full Duplex (MDIX) 8.1OOBASE—TX / Hall Duplex (MD!) 9,1ooBASE-rx I Full Duplex (MDIX) Current Setting : 1 Enler Selecllun([RET]=N0 Change): 4 36 Enter corresponding Port2 inlerface mode number and press the “Enter" key, --- PDrtZ Flow Control --— 1. Enable 2. Disable Current Setting : 1 Enter Seleclionl[REn=No Change): 2 37 Press the “l" or “2” key and press the “Enter" key, -~- PorI2 Far End Link Down Control -—~ 1. Enabled 2. Disabled Current Setting : 1 Enter Selection([RET]=No Change): 2 Note: N01 displayed when Pail rolling m “Enable 38 Press the “l" or “2" key and press the "Enter” key, ROI-806301 SETTING, CONTROL AND MONITORING WITH LCT Chart 5-4 Set Provisioning Data (Cont’d) Step Procedure —-- Main Interface Setting —- —-- 45M Llne Length Seteet -— 1. 0 - 255" (0 » 68m) 2 255 ~ 450fl (68 -135m) Current Setting : 1 Enter Selection([RET]=No Change)’ 2 39 Press the “1“ or “2“ key and press Ihe “Enter" key, 40 After pressing the “Enter" key, the menu shown in step 1 is displayed‘ 41 Press the “2" key for setting the BER Threshold and press the “Enter" key, —-- BER Threshold --- 1. High BER 2. Low BER Enter Selecfion : 1 42 Press the “1" key and “Enter” key for setting the High BER threshnld level, —- High BER 1. 3E—4 2, 3E~5 3. JE-G Curveni Setting : 1 Enter Selech’on (iRETl = No Change) : Note .- Normally, apply 313-4 rccummended values (default). 43 After setting the High BER, press the “Enter" key, 44 Press the “2” key for setting the BER Threshold and press the “Enter" key, _ BER Threshold h 1. High BER 2. Low BER Enter Selection : z 5-35 SETTING, CONTROL AND MONITORING WITH LCT ROI—806301 5-36 Chart 5-4 Set Provisioning Data (Cont’dt Step Procedure 45 Press the “2" key for setting of Low BER threshold, _ Low BER -— 1. 35-6 2. 35-7 3. 35-3 Current Setting : 1 Enter Selection ([RET] = No Change) » Note .' Normally, app/y 35-6 recommended values (default). 46 Press the “1“, “2" or “3” key for corresponding of the Low BER threshold and press the “Enter" key, 47 Afier pressmg the “Enter" key, the menu shown in step 1 is displayed, 48 Press the “3" key for setting the Wayside Interface and press the ”Enter” key, —-- Wayside Intertaee Usage --~ 1. Not Used 2, 145MB (AMI) 3, 1.5MB (5825) Current Setting : 1 Enter Selection (mm = No Change) : 1 49 Press the "l", “2" or “3" key for corresponding of the Wayside Inlerface and press the “Enter" key, --— Wayside Inteflace Line Length —» 1, 0-133fl( 0-401“) 2, 133 - 266K ( 40 - 81m) 3. 266 - 399" ( 81 » 121m) 4. 399 - 533m (121 » 162m) 5, 533 - 6550! (162 » 199m) Current Setting : 1 Enter Selecllon (men : No Change) : Note: Not dispzuym when ws domain n- uredfm' LAN. 50 Chose corresponding ofline Wayside interface length, 51 After pressing the “Enter" key, the menu shown in step 1 is displayed, ——-—.—_——_ ROISOGGM SETTING, CONTROL AND MONITORING WITH LCT Chart 54 Set Provisioning Data (Cont'd) Step Procedure 52 Press the “Enter“ key, the menu shown in step 1 is displayed, 53 Press the "4” key for setting the SC Assignment and press the “Enter“ key, When the SC is applied in LAN-Portl/Pon—Z Assignement, this SC Assignemenl seting item is masked DSC CH is assigned to LAN Port by LAN-Portl/PortZ Assignement preference as follows. LAN-PolfllPortZ P 1 2 Assignment Th “1 ( I use CHILAN Port Assignment roughput Portl Porll SC N/A Portl LAN P0111 for DSCI I. 64 kbps Ponl LAN Port! for DSC1+DSC2 2. 128 kbps SC SC - LAN Port] for DSCI, LAN P0r12 for DSC2 SC WS Porll LAN Port] for DSCI l. 64 kbps Port] LAN Port] for DSCH-DSCZ 2. 128 kbps Main SC Port2 LAN Ford for DSC2 1. 64 kbps P0112 LAN P0112 for DSC1+DSC2 2. 128 khps SC (Shared) Peril-+2 LAN P0nl+2 for DSCI 1, 64 kbps Ponl+2 LAN Forth-2 for DSCI+DSC2 2. 128 kbps 5-37 SETTING, CONTROL AND MONITORING WITH LCT ROI-806301 Chan 5—4 Set Provisioning Data (Cont’d) Step Procedure -— Rszszc Setting 1. Not Used 2. 0301 3. 0502 Current Setting : o Enler Selection (men = No Change) : 1 SC Assignment sets Used/Not Used for service channel and signal assignment. As service channel, two digital v1] (64K) signals and one RSZZZC channel can be used. SC items which are not assigned for Main interface appear at No.1 and No.2. 54 Press the “I”, “Z“ or “3“ key for setting of the RSZ32C interface and press the “Enter" key, — v11-1 Setting -— 1. Not Used 2. DSCI 3. D502 Current Setting : 0 Enter Selection (IRETI = No Change) : 3 55 Press the “”,l “2" or “3“ key for setting ofthe Vll»l interface and press the “Enter“ key, Nate: Two V1] channels can he used either 641: or 9.6k. But when 9. 6k ix used, "comm direcliona ” should be xelecled ax clock direction. --» V11»1 Directional Setting »-- 1. Co—Directional 2. Contra»Direi:tional Current Setting : 0 Enter Selection ([RET] = No Change): 1 56 Press the “l" or “2“ key for selting ofthe V1 l—l directional and press the “Enter" key, 5-38 ROI»506301 SETTING, CONTROL AND MONITORING WITH LCT Chart 54 Set Provisioning Data (Cont'd) Step Procedure ~- v11-2 Setting —. 1A Not Used 2. 0501 a. D802 Current Settlng : 0 Enter Selection ([RET] = No Change) : a 57 Press the “”1 “2“ or “3" key for setting of the V 1 1-2 interface and press the “Enter” key, — Vt1-2 DIreelionai Setting -- 1. CEO-Directional 2, Contra-Directional Current Setting : 0 Enter Selection (men = No Change) : 1 58 Press the “l” or “2" key for setting of the V1 1-2 directional and press the “Enter" key, 59 After pressing the “Enter“ key, the menu shown in step 1 is displayed, 60 Press the “5" key for setting the MTPC TX PWR and press the “Enter" key, —- MTPC Tx PWR —- Current (-23 to ME) : 15 Enter Selection ([RE'|1 = No Change) : MTPC TX PWR sets the lmnsmission power in MTPC operation. If the attenuation is set to 0 dB, maximum output power is obtained. The level is not indicated in the ATPC mode. The MTPC range depends channel capacity as 8 X 1.5MB . ~23 dB to 0 dB system. 16 X 1.5MB/28 >< 1.5MB/l >< 45MB: —20 dB to 0 dB system. 61 After pressing the “Enter“ key, the menu shown in step 1 is displayed, 5-39 SETTING, CONTROL AND MONITORING WITH LCT ROI-506301 5-40 H— Chart 5-4 Set Provisioning Data (Cont’d) Step Procedure 62 Press the “6" key for setting the ATPC Range and press the “Enter" key, ATPC Maximum PWR -- Current (-23 (0 (MB) : 0 Enter Selection ([RET] = No Change) : — ATPC Minimum PWR Current (-23 to [MAX]dB) . -10 Enter Selection ("2571 = No Change) : ATPC Range sets the maximum or minimum transmission power during ATPC operation. If the ATPC Maximum PWR 15 set to 0 dB, the maximum output power is obtained. In the MTPC mode, ATPC menu will not appear. Note: Example of A TPC setting. Whefie ATPC MAXIMUM PWR ofATPC Range ls 581 to 0 dB, ATPC MINIMUM PWR is MI [0 -10 dB and RX Threshold to -60 dBm. In rhix case, if RX level is lower than -60 dBm, monitor/control it performed with the interval of 8 mSec. RX level ix monitored in 1 (13 step, and TX output is controlled in 1 dB step. However. afixed hyt'tcrextlr of 5 dB referred to the RX Threshold is implementedfor ATPC operation Era/nple: ”RX Threxhnla' is set to —60 dBm, no uutput control is made “ft/Em“ the RX level goes below -60 dBm or goat above -55 dBm, m that [he receive level ix maintained within ~60 In -5 5 (Him by A TPC. -55 dBm 5 dB (ATPC RX LEVEL HYSTERESIS) -60 dBm (RX THRESHOLD LEVEL) 63 After pressing the “Enter“ key, the menu shown in step 1 is displayed‘ R0l$08301 SETTING, CONTROL AND MONITORING WITH LCT Chart 54 Set Provisioning Data (Cont’d) Step Procedure 64 Press the “8" key for setting the RX Threshold and press the “Enter" key, -— RX Threshold—- Current (-70 to -30dBm) : -55 EnIer Selection (men = No Change) : RX Threshold sets the threshold value of receiving level. 65 After pressing the “Enter“ key, the menu shown in step 1 is displayed‘ 66 Press the “9" key for setting the Additional ATT and press the “Enter“ key, — Additional A'I'I' -- Current (0 to 5am : 0 Enter Selection (IRE'I'J = No Change) : The additional ATT is a span attenuator that is used to reduce the transmit power like in cases where the transmission length is shcrti First, the transmit output power is adjusted by setting the MTPC TX Power. If the MTPC TX Power setting is insufficient. then set the Additional ATT. The available setting range is from 0 to 5 dB. 67 After pressing the “Enter" key, the menu shown in step 1 is displayed 68 Press the “l ". “0" key for setting the TRP ALM Mode and press the “Enter" key. -- TRP ALM Mode --- 1. MAX Hold 2, MIN Hold 3. Hold Current Setting : 3 Enter Selection ([RET] = No Change) : 541 SETTING, CONTROL AND MONITORING WITH LCT ROI-506301 5-42 Chart 5-4 Set Provisioning Data (Cont‘d) Step Procedure 69 70 This item defines the TRP transmit power level when communication between MDP and TRP is lost. This function is net used when the equipment is set in MTI’C mode and is not displayed. MAX Hold : Selects this to control the TR? output level for the ATPC Maximum PWR setting level. MlN Hold : Selects this to control the TRP Output level for the ATPC Minimum PWR setting level. Held: Selects this to keep the TRP to output level to maintain the level at the time of failure has occurred. Afier pressing the “Euler" key, the menu shown in step I is displayed, Press the “l”, “I" key for setting the TX SW Priority and press the “Enter“ key (in 1+1 system only), —- TXSW Priorlty -» 1. Non-priority 2, Priority No. 1 Current Setting : 1 Enter Selection (men = No Change) :1 71 72 73 “I" Press or “2“ key to select Non-priority/Priority No.1 mode and press the “Enter" key, Press the “l", “2" key for setting the RX SW Priority and press the “Enter" key (in 1+1 system only), Afier pressing Ihe “Enter” key, the menu shown in step I is displayed, ROI$06301 SETTING, CONTROL AND MONITORING WITH LCT Chart 5-4 Set Provisioning Data (Cont‘d) Step Procedure -, Rxsw Priority — 1. Non-priority 2, Priority No. 1 Current Setting : 2 Enter Selection (peer) : No Change) zr 74 Press “I" or “2“ key to select RXSW Priority mode and press the “Enter" key, 75 Press the “1", “3" key for setting Ihe Channel Usage Error and press the “Enter" key, Nate: Applies only to 8/16/28 >< 1,5 MB system, 76 After pressing the “Enter" key, the menu shown in step I is displayed, -- Channel Usage Error —— 1, Report 2. No! Report Current Setting : 2 Enter Selection ([RET] = No Change) : This item sets the whether Main Interface Usage alarm is displayed, or it does not displayed. Report: In Main Interface Setting item, when 15 MB bipolar signal is inputted into the channel which has chosen “Not Used”, alarm is displayed. Not Report: In Main Interface Setting item, when 15 MB bipolar signal is inputted into the channel which has chosen “Not Used”, alarm is not displayed. Note: The alarm of Channel Usage Ermr is displayed an the Channel Usage Error item Of Alarm/Status. And the MDP ALM indicator on the from of the MDP is lighted. 77 After pressing the “Enter" key, the menu shown in step 1 is displayed, 5-43 SETTING, CONTROL AND MONITORING WITH LCT ROI606301 5-44 Chart 5-4 Sat Provisioning Data (Cont’d) Step Procedure 78 Press the “I", “6“ key for setting the AIS Activation Condition and press the “Enter“ key, —— AIS Activation Condition -—» 1. LOF or High BER 2, LOF Current Setting : 1 Enter Selection ([RET] = No Change) : AIS Activation Condition sets the whether AIS signal for main 1.5 MB is by LOF, l-Iigh BER or both alarm conditions. LOF or High BER: When the High BER or LOF ALM is occuned, Main l.5 MB AIS signal ls generated. Note: Selling point Q/High BER ALM can be sci Iiy BER threshold item in 3 x 10-4 m 3 x m“? LOF: When the LOF ALM is occurred, Main 1.5 MB AIS signal is generated. 79 After pressing the “Enter” key, the menu shown in step I is displayed, 80 Press the “I“, “7” key for setting the AIS Activation Delay Time and press the “Enter" key, AIS Activation Delay Time 1. Exclude 2, Include Current Setting : 2 Enter Selection ([RE'I] = No Change) : AIS Activation Delay Time sets the whether AIS signal generation for main 1.5 MB has delay time or it has not. RI After pressing the “Enter" key, the menu shown in step 1 is displayed, ROI-806301 SETTING, CONTROL AND MONITORING WITH LCT Chan 5-4 Set Provisioning Data (Cont’d) Step Procedure 82 Press the “1", “8" key for setting the AIS Generated Report and press the “Enter" key, --- AIS Generated Report --- CH Select (CHOt-OS) : s —- AIS Generated Report »— 1. Report 2. Not Report Current Setting : 1 Enter Selection (lRETFNo Change) : AIS Generated Report sets the whether AIS signal generation for main 1.5 MB is reported or not reponed. Note .» CH Sales! (CHUl-08)for8 x 1.5MBsystem CH Selecl (CH01-16)for 16 x 1.51143 system CH Select (CH01~28)_/nr 28 x 1.5MB system 83 After pressing the “Enter“ key, the menu shown in step 1 is displayed, 84 Press the “l”, “9" key for setting the AIS Received Report and press the “Enter" key, — AIS Received Report ,- CH Select (CHO1»0&) : 6 -- AIS Received Report —— 1. Report 2. Not Report Current Setting : 1 Enter Selection (IRETFNO Change) : AIS Received Report sets the wheIher AIS signal generation for main 1.5 MB is reported or not reported. Note .' CHSe/ect (CHfll-08)for8 >< 1.5MB yyrlem CHSelec! (CHOl-I6)for I6 >< I.5MBsystem CH Salsa! (CHOI-28)fnr 28 X 1.5MB syxtem 85 Alter setting the Provisioning data, proceed to Chart 5—4 for the optional relay house keeping setting, as required. Otherwise, press Ihe “ESC” key to go back to the Main menu. 5-45 SETTING, CONTROL AND MONITORING WITH LCT ROI-806301 5.6 Relay/House Keeping Setting Chart 5-5 Relay/House Keeping Setting This chart describes the procedure for setting the parallel alarm output and the control input/output of House Keeping, The procedure in this chart is to be performed, if required. Step Procedure 1 Press the “ESC” key twice to go back to the following Main menu, —- NEC PDH RADIO VER. X.XXAXX --» 0, Logout 1. Alarm / Stains 2. Pertormance Monitor 3. Provisioning Data 4. System Cnnfiguration 5. Inventory Data 6, Relay I House Keeping 7A Maintenance Enter Seleclion : 2 Press the “6“ key for Relay/House Keeping and press the “Euler“ key, Enter Seleclion : 6 —- Relay! House Keeping —. I. Display Current State 2. Relay Configurancn 3. Output Control Enler Selectlon : The relay configuration setting and alarm output selection is explained below. Display Current State Selects to display House Keeping current state. 3 Press the “1" key and press the “Enter“ key to display Relay/ House Keeping Current slate, 5-46 ROI»SDG301 SETTING, CONTROL AND MONITORING WITH LCT Chart 5-5 Relay/House Keeping Setting (Cont’d) Step Procedure —-- Display Current State —-- HK-IN1 HK-IN2 HK-IN3 HK-IN4 HK-IN5 HKvING Open Open Open Open Open Open HK—OUT1 HK-OUTZ HK-OUTS HK-OUTA On OIf Off Off HK—OUT appears, only when relay output is assigned. 4 Press Ihe “2" key for setting the Relay Configuration and press the “Enter" key, Relay Configuration Eleven (ll) relays are provided to the parallel salami/control outputs. The relays from RLl to RLS are fixed as MAINT, PS and CPU alarm and are not be able to change the setting. The relays from RL4 to RL7 are assigned for equipment alann outputs by default value. The relays from RL8 to KL” are defined as l-IK CONT outputs by default value. The relays RL8 to RLll are possible to assign as alarm outputs instead of HK CONT outputs as shown in the table below. The alarm items which are assignable alarm output through RL4 to RLll are refened to Table 2-2 in chapter 2 ofOperation, 5-47 SETTING, CONTROL AND MONITORING WITH LCT ROI$06301 5-48 Chart 5-5 Relay/House Keeping Setting (Cont‘d) Step Procedure l.HK-OUT1/2/3/4 Enable HK—OUT4 HK—OUT3 HK-OUTZ HK-OUTl 2.HK-OUT1/2/3 Enable ALM HK-OUT3 l—lK—OUTZ HK-OUTI 3. HK—OUT 1/2 Enable ALM ALM HK~OUT2 HK-OUTI 4. HK-OUT I Enable ALM ALM ALM HK-OUTI 5. l-LK-OUT Disable ALM ALM ALM ALM RM to RLll are Form~C relays. In the normal or control all“ conditions. between COM and NC terminals of the relays makes and between COM and N0 terminals brwks. In the alarm or control on conditions, between COM and NC tenninals of the relays breaks and between COM and N0 terminals makes. G NC (Normally Closed) COM (Common) M NO (Normally Open) (Form-C) Note:Tha relay is rated at 0.2 A. lfthe [our HK control output are required, press the “1" key and press the “Enter” key, Relay Configuration 7- 1. HK—OUT 112/314 Enable 2. HK—OUT 11213 Enable 3. HK< Zea) (Fm TRP) Fig‘ 2-2 Packing List for the TRP and MDP (2I2) INSTALLATION ROI-306302 33 m5. Ea ans. 3 5. 55.5“... E 1: 953m 2 9“. Exam ms. 3 x $55“. Qévmeomzzg «332 U |||||||||||||||||| ._ 6.22196?on «2.58: D IIIIIIIIIIIIIIIII ._ 955 «98.28 «3&5 D IIIIIIIIIIIIIIII m._<§mo»omzzou mflaoos D lllllllllllllll .B<§Eo.5mzzoo mama D IIIIIIIIIII Eu we massmorowzzon. mama. _H_. I | J £45105?on wand D | ._ 10 82.60 fiéswuv 1.x mowomzzOo x30: NT | | | , tag. @ onzzOu mizfi _ 95 D _ wz moruuzzoo xmaoz nobomzzoo _ mar/n _ figs mobmzzoo mzmé Ht _ 52.5 mOPomzzou mDWD D ||||| L 6125962on «5302 m ||||||||| L fleas; 1985.8 13332 D |||||||||| L mdé zokomzzoo «53005 D IIIIIIIIIIIII L 955 128.28 mfizoos D IIIIIIIIIIIIII L E35 mopumzzou «5:82 D IIIIIIIIIIIIIII 64.5198:ch «3:8: D IIIIIIIIIIIIIIII L N10 m 2 2~5 ROI$06302 INSTALLATION 65 LE ncm Ln: 3 5. 53:52. 5. a: 9.231 n.N EL 5526 m2 me x mN Lou 735535?on «3:82 D IIIIIIIIIIIIIIIIII ._ 7m._ 0° 0° 00 or.) SIDE VIEW 2 Align the MDP to the mounting position on the 19-inch rack. SPRING WASHER FLAT WASHER SPRING WASHER FLAT WASNER SCREW R0|-806302 INSTALLATION Chart 2-5 Mounting Methods of MDP (Cont’d) Step Procedure 3 Fix each side of the MDP to the 19-inch rack wilh lhe two screws. Fixing Fronl Posing" Fixing Center Position 2-21 INSTALLATION ROI—806302 Chart 2-5 Mounting Methods of MDP (Cont‘d) Step Procedure 4 To mount Ihe MDP in a I9-inch rack, leave space for one unit al the top and bottom to allow heat from the MDP to radiate. A1 least - Al least JV~ one rack um! um rack unvl Mmelnan Maeman _. 200mm 7 200mm “2523233223 -—— zszssssss -—- EEEEEEEEEEEE 333333331: A has ‘ At least one lack uml y one rack unn Hm Sunace Canaan. [mm/1 Me cquipmem in (hcplace when n u um MDP mv/ricmd (mess Ioralmn regulated wilh UL60950-I When open mm above MDP is mam lhau one rank unit (approximawly 45 mm), hesides the mvirvmvmm lampt'mmm 15 higher than + mm: (none) , to avoid roman with we hm surfing 13/1/12 MDP, ins/all a gnarl/plate a: ximwn infigum Iefi‘, 2-22 ROI-305302 INSTALLATION 2.3.2 MDP Demounting For demounting the MDP (if necessary) use the following procedure. Chart 2-6 MDP Demounting step Procedure 1 Turn offlhe power switch of the MD UNlT No.1 and No.2, 2 Disconnect power supply cables from the SELV jack on the MD UNlT No.1 and No.2, 3 Disconnect IFL cables from the MD UNIT No.1 and No.2, 4 Disconnect signal cables from the signal interface connectors on the CTRL UNIT, 5 Disconnect ground cables from the MD UNIT No.1 and N02, 6 Remove Ihe four holding bolts from both sides of the MDP, 7 Remove the MDP from the rack. IFL POWER SWITCH SCREW _,_ 39. v o ' SCREW Fe m .. mm L x u SCREW 1 1 SCREW M “M sen. v 2-23 INSTALLATIO N ROLSOSSOZ 2.4 TRP Mounting/Demounting (Split Type) Install the equipment in the place where it is net restricted access ltrcation regulated with UL60950-l. 2.4.1 TRP Mounting (Coaxial Cable Type) 5.8/L6/u§ GHZ TRP MOUNTING (Connuting Coafil Cable) MOUNT‘NG BRACKET Step 1. Mount the bracket ten the pole, point to the opposite station and tighten it with two U-bolts, mm NUT’ Note: The diameter ofpuie is from 48.5 In "N?“ NUT I I 4. 5 millimeters. spams WASHER usou FLAT WASHER ‘ fight/suing mraue » 34 0 NW k um Step 2. Mount the TRP on to the bracket and tighten four bolts (M6) at upper and lower parts of the ODU, Ms mitten-"q totque‘ A a Aim 1 1m Step 3A Check that the TRP and the bracket are fixed firmlyt Caution: Before connecting the [FL cable between the MDP and TR}: using the circuit tester, check that the resistance of the l/F cable between center conductor and insulalian is mare than 100 Mr). Fig. 2-4 548/LGIUG GHZ Band TRP, Pole Mounting (113) 2-24 ROI-506302 INSTALLATION 5.8/l4‘LIU6 GHz TRP MOUNTING lConnectim Coaxial Cable) CABLE COAXlAL CABLE r 7 4 TIGH l Nut ANTENNA | ‘\ | rgnstOeL L 7 _ _ r/ POLE . Step 4, Connect the Coaxial cableto : the RF lN/OUT connector /TRP ofthe TRP, Step 5. Down the cable to fix the Coaxial cable to the Cable Holder, then tighten the two ‘ bolts, Step 6. Install the Coaxial cables to the antenna and TRP. 0LTS (M5) Ttgnte'mng tamue’ 3 a N m 10% O»Ring l w s'her Spring Washer (When the wave guide 1 \ | Bolt (M4) flange is provided to the t \\ antenna port fit the \ l‘ ’. , 7 _ _ 15:3; 241 transducer wtth etghl bolts. ) w: Nnte. Tightening torque if I 4 N-m t WA Nolu‘ Be (mm! not to damage the (lying Nate: Fix the coaxial cable to the pole nr member with cable hanger or cable tie: after antenna orientation has been camp/emf. Caution: Wrap the coaxial cable ctmnect‘ilm paints with a self- brmding tape for waterprnafi TRP Flgl 2—4 5.8/L6/U6 GHz Band TRP, Pole Mounting (213) 2-25 INSTALLATION Relsoeaoz §.§[L6[U6 GHz TRP MQLLN mg (annecling Coaxial ngz a) . > BOLT ANT ’ d) BRACKET COAXIAL CABLE' TIGHTEN BOLTS (M5) ngnienvng 1°.tu 3 0 N an 10% COAXDAL CABLE §JD£§LLEW N04 ODU Naie.‘ "‘ When coaxial cable with SMA (S) cnnnector is used, the conneclam are supplied by NE C1 LJ§IN§ HYB FOR 1+ §1§ EM No.2 ODU COAX'AL CABL Nam: Antenna separation (S) is given by path caicuratinn depending on the system parameter. 1 +1 §Q S! S EM Cautian: Wrap the coaxial cable connection [mints with a self-banding tape far waterproof Fig. 2-4 5.3/L6IU6 GHz Band TRP, Pole Mounting (313) 2-26 ROI-506302 rai Ta ODU IFL CABLE IFL ABLE L Aug g Type ODU IFL CABLE INSTALLATION Caution When connecting the [FL cable to the ODU, tighten the N-male connector with engage connector nut only using fingers and holding the cable with another hamL Tighten the engage mnnector not only for the L-angle connector also. (Tightening Torque : 0. 7m 1.2 N-rn (7 to 12 kg-crn)) If rotate other parts of the L-angle connector as illustrated left, it can cause connector damage. 2-27 INSTALLATION ROI-506302 2.4.2 TRP Demounting (Coaxial Cable Type) For demounling the TRP (if necessary), use the following procedure. Chart 2-1 TRP Demounting Step Procedure l Turn offlhe power swilcl) ofthe MD UNIT No.1 and No.2, Disconnect IFL cables from the TRP No.l and N02. Loosen screws of the Cable Holder, Disconnect ground cable from “FG” terminal on Ihe TRP, 4 Discounccl coaxial cable from the RF lN/OUT of the TRP, 6 Remove the four holding balls from holh sides of the TRP, Remove the TRP from the bracket. IFL Cable Coaxial Cable Cable Holder Ground Cable Holding Balls 2-28 ROI—806302 INSTALLATION 2.4.3 TRP Mounting (Antenna Direct Mounting) SYSTEM The procedures for mounting and demounting the TRP are described here. There are two types of mourning for the antenna direct mounting type and waveguide connecting type. The TRP should be installed in the radio station. The tools for installation are listed in Table 2-1. Table 2-1 Tools Cautian I. Haw to use small and large 0~rings are shawn in following table. Two (small and large) O-rings are attached in 24 GHz band Andrew/RFS direct maant antenna. [0.5/11 GHz band antenna does not have small 0-ring (Small O-ring is net used for Andrew/RFS direct mount antenna). If the small O-ring is used for TRP direct mount installalilm, a gap may (wear between TRP and antenna far RF inter/am Therefore it may happen transmit a! receive level dawn. Cautitm 2. D0 nut apply silicon grease al 0-ring. ATTACHENENT POS|TION or O-RING (BETWEENzl ANTgTRP O-RING REMARKS SMALL SIZE LARGE SIZE Antenna direct mounting ANT 7 WG/TRI’ (24 am BAND) Waveguide connection ANTfHYB Antenna direct mounting ANT — WG/HYB (24 GHz BAND) Notes: Waveguide connection [0.5/ll GHZ antenna/or dxrecl mount ix not passible to connect the ordinary waveguide flanges. 2-29 INSTALLATION Relsoeaoz POSITION OF LARGE SIZE O-RING POSITION OF SMALL SIZE O-RING FOR WAVEGUIDE CONNECTION FOR ANTENNA DIRECT MOUNTING ANDREW ANTENNA POSITION OF LARGE SIZE O-RING POSITION OF SMALL SIZE O-RING FOR WAVEGUIDE CONNECTION RFS ANTENNA FOR ANTENNA DIRECT MOUNTING Notes: 1. Do not use both small O-ring and large O‘ring simulraneously. 2. O-Ving size is differem with frequency band axfollows: 10-11 GHz BAND 24 GHz BAND LARGE SIZE O-RING FOR ANTENNA DIRECT MOUNTING ' '\56mm E _ 0mm 55 . 1 J 5 mo _<=T 24 GHz BAND SMALL SIZE O-RING FOR WAVEGUIDE CONNECTION 240 ROI-506302 INSTALLATION ______________————— Chan 2-8 Change of Polarization (Antenna Direct Mounting) _________.——————— Step Procedure __________’————— CHANQE OF POLARIZATION TRP DIRECT MOUNTING TYPE ANTENNA (Example (ANDREW) 1/2) Note: The details are refermd to the installation manual which is attached to the antenna. The installatian Dr removal of the antenna requires qualified experienced personnel, Note: The antenna is set to V-polarization when shipped/ram lhefactnry, I Keep the antenna stand horizonlalIy, 2 If you change to H polarization, loosen the four screws with the Allen key wrench and then rotate the Transilion hub of feed, keeping the antenna sland horizontal. ,..V Transilion hub 2 SCREWS 2 SCREWS 2-31 INSTALLATION 2-32 ROI$06302 Char! 2-3 (Cont'd) Step Procedure Nate: Du not remove the SCI‘QW complete from the screw hole. Hold the feed horn with hand. 3 Holding the feed with hand, rotate the feed 90 degrees, Check that the aperture part of the Transition hub is rotated 90 degrees, then fix it with the screws that were loosened in step 2, Top Polanznlirm I’Dhrimllon v H 4 Check that the aperture part of the Transition hub is rotated 90 degrees, then fix it with the screws that were loosened in step 2 Note. When a large and a small gasket are included in the antenna package. Please use the large (me (T he small gasket is not wed in antenna mount)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 62 XMP Toolkit : XMP toolkit 2.9.1-14, framework 1.6 About : uuid:b7693363-a39a-4a66-9b0d-0d0e2579f477 Producer : 1815dn (PDF - 300 dpi) Create Date : 2008:08:24 09:42:02-05:00 Creator Tool : ScanPDFMaker 1.0 Modify Date : 2008:11:05 15:00:44-05:00 Metadata Date : 2008:11:05 15:00:44-05:00 Document ID : uuid:ac4ee213-d026-4879-98a6-7fc6af264426 Format : application/pdf Creator : ScanPDFMaker 1.0EXIF Metadata provided by EXIF.tools