NEC NWA-055300-004 NWA-055300-004 MODEM-A User Manual NWD 107458 04E Safety
NEC Corporation NWA-055300-004 MODEM-A NWD 107458 04E Safety
NEC >
Users Manual
- 1- SAFETY INFORMATION The safety information provides admonishments regarding installing, operating, and maintaining the equipment. To prevent the equipment damages or body injuries, please familiarize yourself with the contents of safety information and other instruction manuals before installing/operating/maintaining the equipment. The indications (Danger, Warning and Caution) shown below are used in the Instruction manuals: GENERAL DANGER WARNING CAUTION Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Indicates an imminently hazardous situation which, if not avoided, could result in serious injury or physical damage. Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or physical damage. It is also said to alert against inappropriate practice. This system should be installed, powered on and maintained only by the appropriate service personnel, who is/are skilled enough to be aware of hazards to which the personnel may be exposed during operation, and of measures to minimize the risks to the personnel or others. SAFETY INFORMATION NWD-107458-04E March, 2011 -2- LABELS Caution and Warning labels attached to the IDU and ODU are as follows: To prevent IDU and ODU from being damaged, do not disconnect I/F cable between IDU and ODU while in operation . The –48 V DC power is superimposed on the center conductor of the I/F cable between IDU and ODU. Connecting the test equipment directly to this terminal may damage it and touching the coaxial cable core may cause an electrical shock. IFL For ODU Type (13-38 GHz) -48V IFL RX LEV MON Ensure not to touch the top surfaces of the IDU and ODU that are heated while in operation. NWD-107458-04E SAFETY INFORMATION - 3 - Caution that the Non-ionizing radiation from the equipment may affect the health. In a system using the optical modules, do not stare CLASS 1 LASER PRODUCT at the laser beams directly.. Laser radiation may be hazardous to eyes and skin. The electrical and electronic products with this symbol are products to follow WEEE. Disposal of NEC equipment or any part of NEC equipment with this mark should comply with regulations implemented by the local authorities or the agreement with NEC. The equipment with this symbol is the subject to compliance with China RoHS in terms of the environmental protection applied to the electrical and electronic equipment. If the caution and warning labels above are out of sight due to the installed condition, please contact NEC. SAFETY INFORMATION NWD-107458-04E -4- WARNING WARNING The –48 V DC power is superimposed on the center conductor of the coaxial cable between IDU and ODU. Connecting the test set equipment directly to this terminal may damage it, and touching the core of coaxial cable may cause an electrical shock. The ODU is designed for using –48 V DC at outdoor environment. Pay attention to a risk of electric shock where the wet condition reduces the contact resistance of the body. WARNING Do not touch the core of I/F cable jack before turning the power off, or it may cause an electrical shock. WARNING In a system using the OPT INTFC modules, do not stare or look at the laser beams directly especially when using the optical instruments, or it may cause damages to eyes and skin. (Class 1 Laser Product). NWD-107458-04E SAFETY INFORMATION - 5 - WARNING This product uses the Class A Lasers. In a domestic environment, this product may cause radio interference in which case the user may be required to take adequate measures. WARNING Do not enter in front of antenna when the transmitter is activating, because the power density of the microwave or milimeter-wave becomes high level along antenna beam. For the details, refer to the Safety Guidance for Microwave Radiation Hazard in NOTICE (Placing). SAFETY INFORMATION NWD-107458-04E -6- CAUTION CAUTION While the equipment is powered on, do not connect or disconnect the power supply plugs, or the DC-DC CONV may be damaged. CAUTION Place ODU within the area protected by lightning rod. To avoid surge currents caused by lightning circulating in the equipment earth system, connect the equipment earth system (frame ground) to ground of the lightning rod at ground level. CAUTION In the event that is believed to be an emergency, such as smokes, burning smells or strange sounds, quit the operation, and turn the power of IDU off, or it may cause damaging the equipment or generating an electric shock. In this situation, do not attempt to fix or repair the equipment. NWD-107458-04E SAFETY INFORMATION - 7 - CAUTION If getting water leakage, metallic shards, smokes, corrosive gas and dusts into the equipment, or if birds or animals approach equipment, the equipment may be damaged. CAUTION Do not attempt to overhaul, modify or repair the equipment, or it may damage the equipment or may result in giving an electric shock. SAFETY INFORMATION NWD-107458-04E -8- NOTICE (PLACING THE EQUIPMENT) 1. Since ODU generates non-ionizing radiation, if the ODU is installed indoors, it may affect the health, which requires to take the adequate measures. 2. Ensure not to block the vents of the equipment. If blocked, the air within the equipment is extremely heated up, which may damage the equipment. Follow the set up and usage rules listed below: Do not install the equipment on the floor covered with a carpet, floor panel heating, or on the bare concrete floor. Do not cover or wrap the equipment with tablecloths, chiffon, rubber or plastic materials. Do not mount the equipment in the bookshelves, locker or in a stuffy place. Do not place anything like books or papers on and against the equipment. 3. The equipment must be installed in the appropriate place. Do not install it sideways or aslant. If it is not properly installed, it may be damaged due to a rise of inner temperature. 4. Do not install the equipment in the following locations, or the equipment may be damaged: The equipment must be installed and maintained in a clean, and dry place where the temperature and humidity are stable, and no dew condensation, which should be within the ranges specified by the manufacturer. 5. For the indoor-type equipment, do not install it where it could be affected by the salt-air, sandy dust, sulphuric acid gas, etc. If the equipment needs to be installed in such place, the following must be considered: (a) Construction of the Equipment Room The room should be airtight or sheltered by external influences mentioned above. NWD-107458-04E SAFETY INFORMATION - 9 - (b) Environmental Temperature Impact for the Equipment In the airtight room, the heat generated within the equipment raises the temperature. An air conditioner for the industrial use is needed to be installed according to the on-site condition. When the air conditioner is installed, do not blow the air directly to the equipment. If the equipment is placed facing the air from the air conditioner, condensation may occur depending on the temperature variation. (c) 6. 7. If installing the equipment in the coastal areas (within 3 km from the seaside), measures to avoid damages by seawater and salt wind are required, for which consult NEC. Places for installing the equipment are restricted to the Telecommunication Center or equivalent. (a) Use twisted pair cables for the power supply cables to suppress inductive interference signals. (b) Use shielded cables for the data transmission cables. (c) Transmission quality degradation may temporarily occur due to the electromagnetic disturbances such as lightning or ESD. The ODU shall be installed at the restricted access location Note #1 by a service personnel. Not e#1: RESTRICTED ACCESS LOCATION is defined as both the following: Accessing to the equipment is allowed only by SERVICE PERSONNEL or by USERS who have enough skills and knowledge of these restrictions and precautions regarding installing locations. Accessing must be protected using a TOOL, lock and key, or other means of security, and is managed by the authority who is responsible for the installed location. Frame Ground (FG) should be connected to the station earth point. For details, refer to the Section I, “INSTALLATION, Frame Grounding.” SAFETY INFORMATION NWD-107458-04E - 10 - Safety Guideline for Using Hazardous Microwave Radiation The Microwave and Millimetre-wave that iPASOLINK series use are very low-level radiation and have never been reported to affect the human health. However, advanced countries have started to regulate things regarding the health hazard, including radiation levels. As for EU countries, it is specified by EN50385. In order to comply with the regulation, an operator should not work near the parabolic antenna if transmitter is activating. Especially the area from side to front of the antenna shows higher radiation level. (See the following illustration and Calculation Example 1.) On the other hand, in front of the antenna, the power density becomes higher level according to the antenna beam. Therefore, the user of this system should pay attention whenever to prevent himself/herself from being radiated. (See the Calculation Example 2 below.) 0.1m for Calculation example 1 ANTENNA 100m for Calculation example 2 ODU - 90 to +90 degrees 0.1m for Calculation example 1 Hazard Area of Radiation In addition, the power density and field strength level are calculated by the following formula: Power density S (mW/cm 2 ) = 10 P+G−30 10 ×K 40 × π × R2 Where: P = Output power of ODU (dBm), G = Antenna Gain (dBi), (in consideration of the angle of antenna) K = Reflection factor =2.56 (given), R = Distance between Human and Antenna (m) Calculation Example 1 (90 degree side of antenna) PASOLINK = 18 GHz/+23 dBm, Antenna diameter = 0.6 m, 0 degree antenna gain = 39 dBi, 90 degrees side antenna gain = −24 dBi, (90 degrees attenuation = −63 dB), Distance = 0.1 m Power density S (mW/cm2) = 0.0016 ≤ 0.01 (European safety guideline) NWD-107458-04E SAFETY INFORMATION - 11 - Calculation Example 2 (0 degree, front side of antenna) PASOLINK = 7 GHz/+27 dBm, Antenna diameter = 1.8 m, 0 degree antenna gain = 40 dBi, Distance = 100 m Power density S (mW/cm2) = 0.01 => Equal to European safety guideline SAFETY INFORMATION NWD-107458-04E - 12 - FAN Unit 1. If a FAN alarm is detected, immediately replace it with the appropriate FAN Unit. While the fans are dismounted or are failed to run, the temperature within the equipment keeps rising, which may degrade the performances. 2. Replace the FAN Unit every three years to guarantee its performance. It is recommended to store several FAN Units for spares. NWD-107458-04E SAFETY INFORMATION - 13 - FCC Statement FCC CAUTION: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipmentand receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. SAFETY INFORMATION NWD-107458-04E
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Encryption : Standard V2.3 (128-bit) User Access : (none) Page Count : 13 Tag P : Warning : XMP format error (no closing tag for aH) Producer : PrimoPDF Create Date : 2011:10:27 15:32:28 Modify Date : 2011:10:27 15:32:28 Title : Microsoft Word - NWD-107458-04E_Safety.doc Creator : PrimoPDF http://www.primopdf.com/ Author : 1139700990585EXIF Metadata provided by EXIF.tools