NIE TECH ZW1505 5 Outlet Power Strip With USB Charger User Manual Evalogik ZW1505 Manual 180628

NIE Technology Co., Ltd 5 Outlet Power Strip With USB Charger Evalogik ZW1505 Manual 180628

User_Manual

Download: NIE TECH ZW1505 5 Outlet Power Strip With USB Charger User Manual Evalogik ZW1505 Manual 180628
Mirror Download [FCC.gov]NIE TECH ZW1505 5 Outlet Power Strip With USB Charger User Manual Evalogik ZW1505 Manual 180628
Document ID3976974
Application IDWaTESUdseonCWdhG6gyKPw==
Document DescriptionUser_Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize39.28kB (491003 bits)
Date Submitted2018-08-24 00:00:00
Date Available2018-08-24 00:00:00
Creation Date2018-07-14 17:26:10
Producing SoftwareMicrosoft: Print To PDF
Document Lastmod2018-07-14 17:26:10
Document TitleEvalogik_ZW1505 Manual-180628.xls
Document Author: Mac.Nie

ZW1505 Z-Wave Plus Power Strip Manual
Federal Communications Commission (FCC) Statement
FCC Caution: Any changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may caus harmful interference to radio communications.However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.Increase the separation between the equipment and
receiver.Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.Consult the dealer or an experienced radio/TV technician for help.This equipment
should be installed and operated with minimum distance 20cm between the radiator and your body.
IC Caution:
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject
to the following two conditions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired
operation of the device.
DECLARATION DE CONFORMITE D'INDUSTRIE CANADA
Ce périphérique a été testé et reconnu conforme aux limites spécifiées dans RSS-210.
Son utilisation est soumise aux deux conditions suivantes :
(1) il ne doit pas provoquer d'interférences gênantes et
(2) il doit tolérer les interférences re.ues, notamment cellessusceptibles d'en perturber le fonctionnement.
WARRANTY
Show Home Products warrants this product to be free from manufacturing defects for
a period of two years from the original date of consumer purchase. This warranty is limited
to the repair or replacement of this product only and does not extend to consequential or
incidental damage to other products that may be used with this product.
This warranty is in lieu of all other warranties, expressed or implied. Some states do not
allow limitations on how long an implied warranty lasts or permit the exclusion or limitation
of incidental or consequential damage, so the above limitations may not apply to you.
ZW1505 Z-Wave Plus Power Strip
This warranty gives you specific rights, and you may also have other rights which vary from
state to state. if the unit should prove defective within the warranty period.
SPECIFICATIONS
WARNING
Model:ZW1505
Power: 120 VAC, 60 Hz.
Signal (Frequency): 908.42 MHZ.
Maximum load for outlet 15A, 1200W Resistive
Maximum load for the Z-Wave controlled outlet:
600W Incandescent, ½ HP Motor or 1200W Resistive
Range: Up to 100 feet line of sight between the Wireless Controller
and the closest Z-Wave receiver module.
Operating Temperature Range: 32-104° F (0-40° C)
For Ourdoor use
Specifications subject to change without notice
due to continuing product improvement
RISK OF FIRE
RISK OF ELECTRICAL SHOCK
RISK OF BURNS
CONTROLLING APPLIANCES:
EXERCISE EXTREME CAUTION WHEN USING Z-WAVE DEVICES TO CONTROL
APPLIANCES. OPERATION OF THE Z-WAVE DEVICE MAY BE IN A DIFFERENT
ROOM THAN THE CONTROLLED APPLIANCE, ALSO ANUNINTENTIONAL ACTIVATION
MAY OCCUR IF THE WRONG BUTTON ON THE REMOTE IS PRESSED. Z-WAVE DEVICES
MAY AUTOMATICALLY BE POWERED ON DUE TO TIMED EVENT PROGRAMMING.
DEPENDING UPON THE APPLIANCE, THESE UNATTENDED OR UNINTENTIONAL
OPERATIONS COULD POSSIBLY RESULT IN A HAZARDOUS CONDITION. FOR THESE
REASONS, WE RECOMMEND DO NOT RETURN THIS PRODUCT TO THE STORE
THE FOLLOWING:
Website:www.nie-tech.com
DO NOT USE Z-WAVE DEVICES TO CONTROL ELECTRIC
HEATERS OR ANY OTHER APPLIANCES WHICH MAY PRESENT
A HAZARDOUS CONDITION DUE TO UNATTENDED OR
UNINTENTIONAL OR AUTOMATIC POWER ON CONTROL.
Introduction:
The ZW1505 is a Z-Wave enabled device and is fully compatible with any Z-Wave Plus enabled network.
Each module is designed to act as a repeater,which will re-transmit a radio frequency (RF) signal by routing the signal
around obstacles and radio dead spots to ensure that the signal is received at its intended destination.
ZW30 is a security enabled Z-Wave plus device. A security Enabled Z-Wave Plus Controller must be used in order to fully utilize the product.
Key Features:
---Remote ON/OFF control via the Z-Wave controller
---Manual ON/OFF control with the front panel push button
---Support Association Group and Auto Report switch status
---Support USB charging report
---Support firmware upgrades via Over-the-air (need Gateways support)
Key function description
Function 1:
Function 2:
Function 3:
Function 4:
Function 5:
Press the button to turn the output ON or OFF
Press the button three times quickly to ADD and REMOVE
Press the button twice quickly and then press and hold the button 10S.device will reset
Press the button three quickly and then press and hold the button 10S.change Parameter 26 value,
Press the button six times quickly,change Parameter 27 value.
USB charging report
Endpoint 6: USB Charging output current, send basic report(0xFF)
Endpoint 7: USB is not Charging , send basic report(0x00)
Z-Wave Remote Control
ADD or Remove the ZW1505 from the existing Z-Wave home control network with your primary controller.
---Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.
---When prompted by your primary controller, click the Up or Down button six times in one second.
Include ZW1505 to/from a Z-Wave Gateway with supporting Security.The ZW1505 can support the Primary Controller that implemented the security S2.
Notice: Including a node ID allocated by Z-WaveTM Controller means “Add” or “Inclusion”. Excluding a node ID allocated by
Z-WaveTM Controller means “Remove” or “Exclusion”.
z-wave protocol Command Class Node Info
COMMAND_CLASS_ZWAVEPLUS_INFO,
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_TRANSPORT_SERVICE_V2,
COMMAND_CLASS_VERSION,
COMMAND_CLASS_MANUFACTURER_SPECIFIC,
COMMAND_CLASS_DEVICE_RESET_LOCALLY,
COMMAND_CLASS_POWERLEVEL,
COMMAND_CLASS_CONFIGURATION,
COMMAND_CLASS_NOTIFICATION_V8,
COMMAND_CLASS_METER_V4,
COMMAND_CLASS_SECURITY_2,
COMMAND_CLASS_MULTI_CHANNEL_V4,
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
The Below listed Command Class are all supported the Security S2
COMMAND_CLASS_VERSION,
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_V3,
COMMAND_CLASS_MANUFACTURER_SPECIFIC,
COMMAND_CLASS_DEVICE_RESET_LOCALLY,
COMMAND_CLASS_POWERLEVEL,
COMMAND_CLASS_CONFIGURATION,
COMMAND_CLASS_NOTIFICATION_V8,
COMMAND_CLASS_METER_V4,
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
ZW1505 protocol Endpoint 1,Endpoint 2,Endpoint 3,Endpoint 4,Endpoint 5,
Full Command Class Node Info
COMMAND_CLASS_ZWAVEPLUS_INFO,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_METER_V4,
COMMAND_CLASS_SUPERVISION,
COMMAND_CLASS_SECURITY_2
The Below listed Command Class are all supported the Security S2
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_METER_V4,
COMMAND_CLASS_SUPERVISION
ZW1505 protocol Endpoint 6,Endpoint 7,
Full Command Class Node Info
COMMAND_CLASS_ZWAVEPLUS_INFO,
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_SUPERVISION,
COMMAND_CLASS_SECURITY_2
The Below listed Command Class are all supported the Security S2
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_SUPERVISION
Z-Wave Configuration Parameters
You may use the below configuration parameters to change settings of the corresponding functionality.
1:Restores state after power failure
Paramter No: 1(0x01) Size:1 Byte
Value: 00 (default)
The state before a power outage.
Value: 01
Output ON.
Value: 02
Output OFF.
2:Power Wattage Report Value Threshold(Wattage)
Value Scope :0----65535W
Paramter No: 2(0x02) Size:2 Byte
Value: xx xx (Default 10W)
Value:00 00
Disabled
3:Power Wattage Report Frequency (Timer)
Value Scope :5----2678400S
Paramter No: 3(0x03) Size:4 Byte
Value: xx xx xx xx (Default 30S)
Value:00 00 00 00
Disabled
4:Energy (kWh) Report Frequency (Timer)
Value Scope :5----2678400S
Paramter No: 4(0x04) Size:4 Byte
Value: xx xx xx xx (Default 300S)
Value:00 00 00 00
Disabled
5:Energy (kWh) Report Frequency (Wattage)
Value Scope :0----1500W
Paramter No: 5(0x05) Size:2 Byte
Value: xx xx (Default 1500W)
6:Endpoint1 Enable Auto Turn-OFF Timer
Paramter No: 6(0x06) Size:1 Byte
Value=0 Auto Turn-OFF Timer Disabled (default);
Value=1 Auto Turn-OFF Timer Enabled
7:Endpoint1 Count Down Configuration(Turn off the output by time)
Paramter No: 7(0x07) Size:2 Byte
Value: xx xx Turn off Output
Value Scope :1----65535Minutes (default:60M)
8:Endpoint1 Enable Auto Turn-ON Timer
Paramter No: 8(0x08) Size:1 Byte
Value=0 Auto Turn-ON Timer Disabled (default);
Value=1 Auto Turn-ON Timer Enabled
9:Endpoint1 Count Down Configuration(Turn on the output by time)
Paramter No: 9(0x09) Size:2 Byte
Value: xx xx Turn off Output
Value Scope :1----65535Minutes (default:60M)
10:Endpoint2 Enable Auto Turn-OFF Timer
Paramter No: 10(0x0A) Size:1 Byte
Value=0 Auto Turn-OFF Timer Disabled (default);
Value=1 Auto Turn-OFF Timer Enabled
11:Endpoint2 Count Down Configuration(Turn off the output by time)
Paramter No: 11(0x0B) Size:2 Byte
Value: xx xx Turn off Output
Value Scope :1----65535Minutes (default:60M)
12:Endpoint2 Enable Auto Turn-ON Timer
Paramter No: 12(0x0C) Size:1 Byte
Value=0 Auto Turn-ON Timer Disabled (default);
Value=1 Auto Turn-ON Timer Enabled
13:Endpoint2 Count Down Configuration(Turn on the output by time)
Paramter No: 13(0x0D) Size:2 Byte
Value: xx xx Turn off Output
Value Scope :1----65535Minutes (default:60M)
14:Endpoint3 Enable Auto Turn-OFF Timer
Paramter No: 14(0x0E) Size:1 Byte
Value=0 Auto Turn-OFF Timer Disabled (default);
Value=1 Auto Turn-OFF Timer Enabled
15:Endpoint3 Count Down Configuration(Turn off the output by time)
Paramter No: 15(0x0F) Size:2 Byte
Value: xx xx Turn off Output
Value Scope :1----65535Minutes (default:60M)
16:Endpoint3 Enable Auto Turn-ON Timer
Paramter No: 16(0x10) Size:1 Byte
Value=0 Auto Turn-ON Timer Disabled (default);
Value=1 Auto Turn-ON Timer Enabled
17:Endpoint3 Count Down Configuration(Turn on the output by time)
Paramter No: 17(0x11) Size:2 Byte
Value: xx xx Turn off Output
Value Scope :1----65535Minutes (default:60M)
18:Endpoint4 Enable Auto Turn-OFF Timer
Paramter No: 18(0x12) Size:1 Byte
Value=0 Auto Turn-OFF Timer Disabled (default);
Value=1 Auto Turn-OFF Timer Enabled
19:Endpoint4 Count Down Configuration(Turn off the output by time)
Paramter No: 19(0x13) Size:2 Byte
Value: xx xx Turn off Output
Value Scope :1----65535Minutes (default:60M)
20:Endpoint4 Enable Auto Turn-ON Timer
Paramter No: 20(0x14) Size:1 Byte
Value=0 Auto Turn-ON Timer Disabled (default);
Value=1 Auto Turn-ON Timer Enabled
21:Endpoint4 Count Down Configuration(Turn on the output by time)
Paramter No: 21(0x15) Size:2 Byte
Value: xx xx Turn off Output
Value Scope :1----65535Minutes (default:60M)
22:Endpoint5 Enable Auto Turn-OFF Timer
Paramter No: 22(0x16) Size:1 Byte
Value=0 Auto Turn-OFF Timer Disabled (default);
Value=1 Auto Turn-OFF Timer Enabled
23:Endpoint5 Count Down Configuration(Turn off the output by time)
Paramter No: 23(0x17) Size:2 Byte
Value: xx xx Turn off Output
Value Scope :1----65535Minutes (default:60M)
24:Endpoint5 Enable Auto Turn-ON Timer
Paramter No: 24(0x18) Size:1 Byte
Value=0 Auto Turn-ON Timer Disabled (default);
Value=1 Auto Turn-ON Timer Enabled
25:Endpoint5 Count Down Configuration(Turn on the output by time)
Paramter No: 25(0x19) Size:2 Byte
Value: xx xx Turn off Output
Value Scope :1----65535Minutes (default:60M)
26:Manual Control
Paramter No: 26(0x1A) Size:1 Byte
Value=0 Manual Control Disabled
Value=1 Manual Control Enabled (default);
27:Status LED Configuration
Paramter No: 27(0x1B) Size:1 Byte
Value: 00
Output ON,Led ON.
Value: 01(default) Output ON,Led OFF.
Value: 02
Always OFF
Support for Association Groups
ZW1505 supports 6 association groups. A maximum of 5 node ID’s (nonmulti-channel devices) can be assigned to these association groups.
Association group_1:Z-Wave Plus Lifeline
Association group_1 is default to associate with the primary controller (Gateway/Hub/Controller) for ZW1505 Status change report,
1. ZW1505 will trigger AUTO report function if the Switch status had been changed.
2. When ZW1505 high temperature alarm sends out notifications or releases notifications, ZW1505 will auto report
Association group_2:basic set command
When the output of the ZW1505 Enpoint1 socket is changed, On (0xFF) or Off (0x00). The ZW1505 will automatically send out a related basic set
command. On (0xFF) or Off (0x00) to its associated group.
Association group_3:basic set command
When the output of the ZW1505 Enpoint2 socket is changed, On (0xFF) or Off (0x00). The ZW1505 will automatically send out a related basic
command. On (0xFF) or Off (0x00) to its associated group.
Association group_4:basic set command
When the output of the ZW1505 Enpoint3 socket is changed, On (0xFF) or Off (0x00). The ZW1505 will automatically send out a related basic set
command. On (0xFF) or Off (0x00) to its associated group.
Association group_5:basic set command
When the output of the ZW1505 Enpoint4 socket is changed, On (0xFF) or Off (0x00). The ZW1505 will automatically send out a related basic
command. On (0xFF) or Off (0x00) to its associated group.
Association group_6:basic set command
When the output of the ZW1505 Enpoint5 socket is changed, On (0xFF) or Off (0x00). The ZW1505 will automatically send out a related basic
command. On (0xFF) or Off (0x00) to its associated group.
Restoring Factory Defaults
ZW1505 is removed from the network and will be restored to the factory setting
All Configuration Parameters values and Association information will be restored to factory default settings and excluded from the network.
Remark : All the setting and data will be permanently deleted.
Please use this procedure only when the network primary controller is missing or otherwise inoperable.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Warning                         : Info object (73 0 obj) not found at 489246
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AQURZW1505

Navigation menu