NIE TECH ZW47 S2 Double Plug with USB Port User Manual 18 11 27 zen25 print manual part1
NIE Technology Co., Ltd S2 Double Plug with USB Port 18 11 27 zen25 print manual part1
NIE TECH >
User_Manual
USER MANUAL S2 Double Plug with USB Port ZW47 WARNING Ÿ This product should be installed indoors upon completion of any building renovations. Ÿ Prior to installation, the device should be stored in a dry, dust-and-mold- proof place. Ÿ Do not install the Double Plug in a place with direct sun exposure, high temperature, or humidity. Ÿ Keep away from chemicals, water, and dust. Ÿ Ensure the device is never close to any heat source or open flame to prevent fire. Ÿ Ensure the device is connected to an electric power source that does not exceed the maximum load power. Ÿ No part of the device may be replaced or repaired by the user. Z-WAVE CONTROL ADD DEVICE to your hub (AUTO INCLUSION) Initiate inclusion (pairing) in the app (or web interface). 2. POWER the Double Plug Plug the device into a grounded 120 VAC receptacle you’re planning to use it at (it doesn’t need to be close to the hub). The LED indicators will start blinking and the Double Plug will join the network automatically. If it lights up in yellow, inclusion has failed. 3. You will see 4 new on/ vices in your app: 2 channels for on/ ontrol, 1 channel for on/ monitoring (the USB port reporting charging/ charged status, no control), and 1 master node to control both outlets at the same time and to access and adjust advanced settings in (if your hub supports parameter input). FEATURES Ÿ Z-Wave on/ ontrol of 2 electrical devices ging/charged) reports from USB port to the hub (no ZŸ On/ the charging device for best results Wave control) - turn Ÿ Energy monitoring for each outlet Ÿ Smart LED indicator displays power use and Z-Wave signal strength Ÿ Built-in overload protection and ETL certification Ÿ Z-Wave Plus signal repeater to extend network range Ÿ S2 security and 500 Z-Wave chip for reliable wireless communication SPECIFICATIONS Ÿ Model Number: ZW47 Ÿ Z-Wave Signal Frequency: 908.42 MHz Ÿ Power: 120 VAC Ÿ Maximum Load: 10 A total (between 2 outlets) Ÿ Maximum Load for USB port: 2.1 A Ÿ Range: Up to 100 feet line of sight Ÿ Installation and Use: Indoor only CAUTION This is an electrical device - please use caution when installing and operating the Double Plug. Remote control of appliances may result in unintentional or automated activation of power. Do NOT use this Z-Wave device to control electric heaters or other appliances which produce the risk of fire, burns, or electrical shock when unattended. INSTALLATION Plug the Double Plug into any standard grounded 110 V receptacle. Do NOT connect any devices to the plug at this point. Click the Z-Wave outlet and double-click it to turn the button once to turn on the right outlet on. See if the LED indicators c . If the LED indicators don’t light up at all, please tr erent receptacle. If they’re , please make sure the Double Plug is on. BEFORE YOU PLUG ANYTHING IN e sure the load you are about to connect does NOT e c in power. This Double Plug can hold up to 10 A in total. It means that the power of all devices connected to your ZEN25 at a given time can NOT exceed 10 A. It doesn’t matter if this is just one device connected to one of the outlets or 2 small appliances plugged into both outlets. GE Connecting heavy duty equipment to this Double Plug will D the device and may cause the connected appliance to malfunction. Ÿ Ÿ Ÿ Ÿ Ÿ Ÿ Ÿ Ÿ Washers Dryers Refrigerators Electric heaters Fans Pumps Chargers Routers Put your Z-Wave hub into inclusion mode and -Wave butt quickly. -WAVE BUTTON USB PORT TROUBLESHOOTING The Double Plug won’t add to your system? Try this: 1. Initiate EXCLUSION and click the Z-Wave button 3 times quickly. 2. Click the Z-Wave button 4-5 times quickly when adding it. 3. Bring the Double Plug closer to your hub, it may be out of range. 4. Double-check if the device is powered. EXCLUSION (REMOVING / UNPAIRING DEVICE) 1. Bring the plug within direct range of your Z-Wave gateway (hub). 2. Put the Z-Wave hub into exclusion mode. 3. Press and release the Z-Wave button 3 times quickly. 4. Your hub will confirm exclusion and all of the channels (child outlets) and the main device will disappear from your controller's device list. FACTORY RESET If your primary controller is missing or inoperable, you may need to reset the device to factory settings. To complete the reset process manually, click-click-click’n -Wave button for at least 0 seconds. NOTE: All previously recorded activity and custom settings EXCEPT for the kWh record will be erased from the device’s memory Wave butt o reset the kWh record fr outle o reset the kWh record from the right outlet. LED INDICATOR How to read LED indicator colors? The LED indicators on your Double Plug will visually report power use and Z-Wave range (see next page for range test details). No light / Whit Cyan = 200 – 400 W Orange = 600 – 800 W Purple = 1000 – 1200 W Blue = 0 – 200 W Green = 400 – 600 W Red = 800 – 1000 W Purple blink = over 1200 W WARRANTY This product is covered under a 12-month limited warranty. FCC NOTE THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT. STORE INDOORS WHEN NOT IN USE. SUITABLE FOR DRY LOCATIONS ONLY. DO NOT IMMERSE IN WATER. NOT FOR USE WHERE DIRECTLY EXPOSED TO WATER. FCC Caution. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. DON’T USE WITH MANUAL INCLUSION OK. TO USE WITH Ÿ Ÿ Ÿ Ÿ Ÿ Ÿ Ÿ Ÿ Floor Lamps Tv’s and Video Computers Game Consoles Alarm Clocks Printers Speakers Audio Players Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. connected. -Consult the dealer or an experienced radio/TV technician for help. *RF warning for Mobile device: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. ADVANCED SETTINGS Please refer to your controller's user guide for advanced programming instructions as they are a lit erent for ever are. ASSOCIATION The Double Plug supports Group 1 for lifeline communication of on/ status to the Z-Wave gateway controller (hub). ad notifications (BASIC_SET) to It supports Group 2 for on/ other devices in the group. CUSTOMIZE YOUR DOUBLE PLUG On/ tatus Recovery A er Power Failure Parameter 1: Choose the recovery state for your Double Plug’s outlets if power outage occurs. Values: 0 – Double Plug remembers the status for each outlet prior to power outage and turns back to it (default); 1 – Double Plug automatically turns ON for each outlet once power is restored (it does not remember the status prior to power outage); 2 – Double Plug automatically turns OFF each outlet once power is restored (it does not remember the status prior to power outage); Size: 1 byte dec. Power Wattage Report Value Threshold Parameter 2: Choose how you want your Double Plug to report power consumption to your hub. The number entered as value corresponds to the number of Watts the appliance needs to go over for the change to be reported. So if 5 Watts are entered by default, the Double Plug will report any change in power usage over 5 Watts for each outlet (whether it’s at least 5 Watts mor att ompared to previous report). Values: 0 – 65535. 0 – disabled (Double Plug will not report power consumption based on this setting). Default set to 5. Size: 4 byte dec. Power Wattage Report Frequency Parameter 3: The number entered as value corresponds to the number of seconds. So if 30 is entered by default, the Double Plug will report power consumption (Wattage) every 30 seconds. Values: 30 – 2678400. Default set to 30. Size: 4 byte dec. Energy (kWh) Report Frequency en you want your Double Plug to report Paramet power consumption (W) to your controller (hub). The number entered as value corresponds to the number of seconds. So if 300 is entered by default, the Double Plug will report energy usage every 300 seconds (5 minutes). Values: 5 – 2678400. Default set to 300. Size: 4 byte dec. Auto Turn-On Timer Parameter 10: Use this parameter to enable or disable the auto turn-on outlet. If this feature is enabled, the device timer for t will automatic er a fixed period of connected t time fr t in parameter 11). Values: 0 – timer disabled (def e: 1 byte dec. er which you want the Parameter 11: Use this parameter to se ) outlet to automatically turn on once it device connected to . The number entered as value corresponds to the number of minutes. Values: 1 – 65535 (minutes). Default set to 60 (minutes). Size: 4 byte dec. Parameter 14: Enable or disable the auto turn-on timer for the right (CH2) outlet. e: 1 byte dec. Values: 0 – timer disabled (def er which you want the device connected to Parameter 15: Se the right outlet to automatically turn on onc Values: 1 – 65535 (minutes). Default set to 60 (minutes). Size: 4 byte dec. Manual Control Parameter 16: Choose if you want to use the Z-Wave button on the Double ant to disable this Plug to turn the outlet function. If this parameter is set to 0 (disabled), you will only be able to turn any of the outlet emotely using your Z-Wave gateway controller. ontrol Values: 0 – manual control disabled for both outlet enabled for both outlets (default). Size: 1 byte dec. LED Indicator Mode Parameter 17: Choose if you want the LED indicators next to each outlet to , or if you want to disable them. Values: 0 – LED indicator will display power consumption whenever the device is plugged in (LED stays on at all times, e ); 1 – LED indicator will display power consumption whenever the device is ON ault); 2 – LED indicator will display the level of power consumption for 5 seconds only whenever the devic ator will st or most of the time); 3 – LED indicator is OFF at all times except for inclusion, exclusion, and Z-Wave range test. Size: 1 byte dec. You can also switch between the LED indicator modes by clicking the ZWave button 6 times quickly. RANGE TEST TOOL Voltage (V) Report Frequency en you want your Double Plug to report Paramet voltage to your controller (hub). The number entered as value corresponds to the number of seconds. So if 300 is entered by default, the Double Plug will report voltage every 300 seconds (5 minutes). Values: 5 – 2678400. Default set to 300. Size: 4 byte dec. Electrical Current (A) Report Frequency en you want your Double Plug to report Paramet electrical current (A) to your controller (hub). The number entered as value corresponds to the number of seconds. So if 300 is entered by default, the Double Plug will report current every 300 seconds (5 minutes). Values: 5 – 2678400. Default set to 300. Size: 4 byte dec. Overload Protection Parameter 7: Set the amp level for overload protection to kick in. The number entered as the value corresponds to the total number of amps the Double Plug needs to detect across both outlets t omatically and send a notification to the hub and associated devices. Values: 1 – 10 (A). Default set to 10 A. Size: 1 byte dec. Auto T Parameter 8: Use this parameter to enable or disable the auto outlet. If this feature is enabled, the device timer for connected to CH1 outlet will automatic er a fixed period of time from being turned on (set in parameter 9). Values: 0 – timer disabled (def e: 1 byte dec. er which you want the Parameter 9: Use this parameter to se ) outlet to automatic e it device connected to has been turned on. The number entered as value corresponds to the number of minutes. Values: 1 – 65535 (minutes). Default set to 60 (minutes). Size: 4 byte dec. Parameter 12: Enable or disable the auto (CH2) outlet. Values: 0 – timer disabled (def timer for the right e: 1 byte dec. er which you want the device connected to Parameter 13: Se the right (CH2) outlet to automatic e it’s been turned on. Values: 1 – 65535 (minutes). Default set to 60 (minutes). Size: 4 byte dec. You can easily check if the Double Plug is within your Z-Wave hub’s range: Press and hold the Z-Wave button for 6 to 8 seconds until the LED indicator turns violet. The LED indicator will then report signal strength. Solid green = direct communication with the primary controller is stable Flashing green = direct communication with the primary controller is established but signal is weak Solid orange = stable communication with hub via repeaters Flashing orange = communication with the primary controller is established via repeaters but signal is weak Solid red = communication with the primary controller has failed Press and release the Z-Wave button to exit testing mode. NOTE: This function may only be activated once the Double Plug has been included to a Z-Wave network. This device requires the following command classes to be supported and recognized by your Z-Wave controller: COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_FIRMWARE_UPDATE_MD COMMAND_CLASS_MANUFACTURER_SPECIFIC COMMAND_CLASS_METER COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION COMMAND_CLASS_MULTI_CHANNEL COMMAND_CLASS_NOTIFICATION COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_SECURITY_2 COMMAND_CLASS_SUPERVISION COMMAND_CLASS_SWITCH_BINARY COMMAND_CLASS_TRANSPORT_SERVICE COMMAND_CLASS_VERSION COMMAND_CLASS_ZWAVEPLUS_INFO S2 This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. This product features the latest Security 2 (S2) framework to remove smart home network hacking risks. This is an ETL certified device. ETL, just like UL, is a Nationally Recognized Testing Laboratory. The ETL mark is proof of product compliance to North American safety standards.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No XMP Toolkit : Adobe XMP Core 5.6-c137 79.159768, 2016/08/11-13:24:42 Create Date : 2018:12:06 10:59:41+08:00 Creator Tool : Adobe Illustrator CC 2017 (Windows) Modify Date : 2018:12:06 11:00:40+08:00 Metadata Date : 2018:12:06 11:00:40+08:00 Thumbnail Width : 256 Thumbnail Height : 232 Thumbnail Format : JPEG Thumbnail Image : (Binary data 34450 bytes, use -b option to extract) Producer : Corel PDF Engine Version 18.1.0.690 Format : application/pdf Creator : A Lo Title : 18-11-27-zen25-print-manual-part1.cdr N Pages : 1 Has Visible Transparency : False Has Visible Overprint : False Max Page Size W : 240.000015 Max Page Size H : 450.000009 Max Page Size Unit : Millimeters Font Name : ArialMT, MyriadPro-Regular, SourceSansPro-Light, SourceSansPro-Semibold, SourceSansPro-Regular, SourceSansPro-ExtraLight Font Family : Arial, Myriad Pro, Source Sans Pro, Source Sans Pro, Source Sans Pro, Source Sans Pro Font Face : Regular, Regular, Light, Semibold, Regular, ExtraLight Font Type : Open Type, Open Type, Open Type, Open Type, Open Type, Open Type Font Version : Version 7.00, OTF 1.006;PS 001.000;Core 1.0.23;hotunix 1.28, Version 1.050;PS 1.000;hotconv 1.0.70;makeotf.lib2.5.5900, Version 1.050;PS 1.000;hotconv 1.0.70;makeotf.lib2.5.5900, Version 1.050;PS 1.000;hotconv 1.0.70;makeotf.lib2.5.5900, Version 1.050;PS 1.000;hotconv 1.0.70;makeotf.lib2.5.5900 Font Composite : False, False, False, False, False, False Font File Name : arial.ttf, MyriadPro-Regular_0.otf, SourceSansPro-Light_0.otf, SourceSansPro-Semibold_0.otf, SourceSansPro-Regular_0.otf, SourceSansPro-ExtraLight_0.otf Plate Names : Cyan, Magenta, Yellow, Black Swatch Group Name : 默认色板组 Swatch Group Type : 0 Rendition Class : proof:pdf Document ID : xmp.did:b86b0e17-3a1b-1345-8bf4-f6f10f360374 Instance ID : uuid:a8b9cf59-e2d3-4d5e-9c6c-75fe7c5d693c Original Document ID : uuid:849d33ca-6823-498c-8d1e-2ee016bfe9ac Derived From Instance ID : uuid:6bb4f3e7-bcef-453e-809e-5c2f4c78f09d Derived From Document ID : uuid:849d33ca-6823-498c-8d1e-2ee016bfe9ac Derived From Original Document ID: uuid:849d33ca-6823-498c-8d1e-2ee016bfe9ac Derived From Rendition Class : proof:pdf History Action : saved History Instance ID : xmp.iid:b86b0e17-3a1b-1345-8bf4-f6f10f360374 History When : 2018:12:06 10:59:42+08:00 History Software Agent : Adobe Illustrator CC 2017 (Windows) History Changed : / Page Count : 2 AI Creator Version : 21.0.0 For : ic, Bounding Box : 0 -1 1423 1276 AI Build Number : 223 AI Color Usage : Color AI Ruler Units : Millimeters AI Color Model : CMYK AI Target Resolution : 800 AI Num Layers : 1 Container Version : 11 Creator Version : 21 Author : A LoEXIF Metadata provided by EXIF.tools