NIE TECH ZW47 S2 Double Plug with USB Port User Manual 18 11 27 zen25 print manual part1

NIE Technology Co., Ltd S2 Double Plug with USB Port 18 11 27 zen25 print manual part1

User_Manual

Download: NIE TECH ZW47 S2 Double Plug with USB Port User Manual 18 11 27 zen25 print manual part1
Mirror Download [FCC.gov]NIE TECH ZW47 S2 Double Plug with USB Port User Manual 18 11 27 zen25 print manual part1
Document ID4105755
Application IDHqa+6UL/ju/PnqQD2y6ZDw==
Document DescriptionUser_Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize133.72kB (1671489 bits)
Date Submitted2018-12-14 00:00:00
Date Available2018-12-14 00:00:00
Creation Date2018-12-06 10:59:41
Producing SoftwareCorel PDF Engine Version 18.1.0.690
Document Lastmod2018-12-06 11:00:40
Document Title18-11-27-zen25-print-manual-part1.cdr
Document CreatorAdobe Illustrator CC 2017 (Windows)
Document Author: A Lo

USER MANUAL
S2 Double Plug with USB Port
ZW47
WARNING
Ÿ This product should be installed indoors upon completion of any building
renovations.
Ÿ Prior to installation, the device should be stored in a dry, dust-and-mold-
proof place.
Ÿ Do not install the Double Plug in a place with direct sun exposure, high
temperature, or humidity.
Ÿ Keep away from chemicals, water, and dust.
Ÿ Ensure the device is never close to any heat source or open flame to prevent
fire.
Ÿ Ensure the device is connected to an electric power source that does not
exceed the maximum load power.
Ÿ No part of the device may be replaced or repaired by the user.
Z-WAVE CONTROL
ADD DEVICE to your hub (AUTO INCLUSION)
Initiate inclusion (pairing) in the app (or web
interface).
2. POWER the Double Plug
Plug the device into a grounded 120 VAC receptacle
you’re planning to use it at (it doesn’t need to be close
to the hub). The LED indicators will start blinking and the Double Plug will
join the network automatically. If it lights up in yellow, inclusion has failed.
3. You will see 4 new on/
vices in your app: 2 channels for on/
ontrol,
1 channel for on/ monitoring (the USB port reporting charging/ charged
status, no control), and 1 master node to control both outlets at the same
time and to access and adjust advanced settings in (if your hub supports
parameter input).
FEATURES
Ÿ Z-Wave on/
ontrol of 2 electrical devices
ging/charged) reports from USB port to the hub (no ZŸ On/
the charging device for best results
Wave control) - turn
Ÿ Energy monitoring for each outlet
Ÿ Smart LED indicator displays power use and Z-Wave signal strength
Ÿ Built-in overload protection and ETL certification
Ÿ Z-Wave Plus signal repeater to extend network range
Ÿ S2 security and 500 Z-Wave chip for reliable wireless communication
SPECIFICATIONS
Ÿ Model Number: ZW47
Ÿ Z-Wave Signal Frequency: 908.42 MHz
Ÿ Power: 120 VAC
Ÿ Maximum Load: 10 A total (between 2 outlets)
Ÿ Maximum Load for USB port: 2.1 A
Ÿ Range: Up to 100 feet line of sight
Ÿ Installation and Use: Indoor only
CAUTION
This is an electrical device - please use caution when installing and
operating the Double Plug. Remote control of appliances may result in
unintentional or automated activation of power. Do NOT use this Z-Wave
device to control electric heaters or other appliances which produce the
risk of fire, burns, or electrical shock when unattended.
INSTALLATION
Plug the Double Plug into any standard grounded 110 V receptacle. Do
NOT connect any devices to the plug at this point. Click the Z-Wave
outlet and double-click it to turn the
button once to turn on the
right outlet on. See if the LED indicators c
. If the LED
indicators don’t light up at all, please tr
erent receptacle. If they’re
, please make sure the Double Plug is on.
BEFORE YOU PLUG ANYTHING IN
e sure the load you are about to connect does NOT e c
in power. This Double Plug can hold up to 10 A in total. It means that the
power of all devices connected to your ZEN25 at a given time can NOT
exceed 10 A. It doesn’t matter if this is just one device connected to one
of the outlets or 2 small appliances plugged into both outlets.
GE
Connecting heavy duty equipment to this Double Plug will D
the device and may cause the connected appliance to malfunction.
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Washers
Dryers
Refrigerators
Electric heaters
Fans
Pumps
Chargers
Routers
Put your Z-Wave hub into inclusion mode and
-Wave butt
quickly.
-WAVE BUTTON
USB PORT
TROUBLESHOOTING
The Double Plug won’t add to your system? Try this:
1. Initiate EXCLUSION and click the Z-Wave button 3 times quickly.
2. Click the Z-Wave button 4-5 times quickly when adding it.
3. Bring the Double Plug closer to your hub, it may be out of range.
4. Double-check if the device is powered.
EXCLUSION (REMOVING / UNPAIRING DEVICE)
1. Bring the plug within direct range of your Z-Wave gateway (hub).
2. Put the Z-Wave hub into exclusion mode.
3. Press and release the Z-Wave button 3 times quickly.
4. Your hub will confirm exclusion and all of the channels (child outlets)
and the main device will disappear from your controller's device list.
FACTORY RESET
If your primary controller is missing or inoperable, you may need to reset
the device to factory settings. To complete the reset process manually,
click-click-click’n
-Wave button for at least 0 seconds.
NOTE: All previously recorded activity and custom settings EXCEPT for
the kWh record will be erased from the device’s memory
Wave butt
o reset the kWh record fr
outle
o reset the kWh record from the right outlet.
LED INDICATOR
How to read LED indicator colors?
The LED indicators on your Double Plug will visually report power use and
Z-Wave range (see next page for range test details).
No light / Whit
Cyan = 200 – 400 W
Orange = 600 – 800 W
Purple = 1000 – 1200 W
Blue = 0 – 200 W
Green = 400 – 600 W
Red = 800 – 1000 W
Purple blink = over 1200 W
WARRANTY
This product is covered under a 12-month limited warranty.
FCC NOTE
THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY
UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE
USER’S AUTHORITY TO OPERATE THE EQUIPMENT. STORE INDOORS WHEN NOT IN USE. SUITABLE
FOR DRY LOCATIONS ONLY. DO NOT IMMERSE IN WATER. NOT FOR USE WHERE DIRECTLY EXPOSED
TO WATER.
FCC Caution.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Any Changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.
DON’T USE WITH
MANUAL INCLUSION
OK. TO USE WITH
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Floor Lamps
Tv’s and Video
Computers
Game Consoles
Alarm Clocks
Printers
Speakers
Audio Players
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates uses
and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
connected.
-Consult the dealer or an experienced radio/TV technician for help.
*RF warning for Mobile device:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the
radiator & your body.
ADVANCED SETTINGS
Please refer to your controller's user guide for advanced programming
instructions as they are a lit
erent for ever
are.
ASSOCIATION
The Double Plug supports Group 1 for lifeline communication of on/
status to the Z-Wave gateway controller (hub).
ad notifications (BASIC_SET) to
It supports Group 2 for on/
other devices in the group.
CUSTOMIZE YOUR DOUBLE PLUG
On/
tatus Recovery A er Power Failure
Parameter 1: Choose the recovery state for your Double Plug’s outlets if
power outage occurs.
Values: 0 – Double Plug remembers the status for each outlet prior to
power outage and turns back to it (default); 1 – Double Plug automatically
turns ON for each outlet once power is restored (it does not remember the
status prior to power outage); 2 – Double Plug automatically turns OFF
each outlet once power is restored (it does not remember the status prior
to power outage); Size: 1 byte dec.
Power Wattage Report Value Threshold
Parameter 2: Choose how you want your Double Plug to report power
consumption to your hub. The number entered as value corresponds to
the number of Watts the appliance needs to go over for the change to be
reported. So if 5 Watts are entered by default, the Double Plug will report
any change in power usage over 5 Watts for each outlet (whether it’s at
least 5 Watts mor
att
ompared to previous report).
Values: 0 – 65535. 0 – disabled (Double Plug will not report power
consumption based on this setting). Default set to 5. Size: 4 byte dec.
Power Wattage Report Frequency
Parameter 3: The number entered as value corresponds to the number of
seconds. So if 30 is entered by default, the Double Plug will report power
consumption (Wattage) every 30 seconds.
Values: 30 – 2678400. Default set to 30. Size: 4 byte dec.
Energy (kWh) Report Frequency
en you want your Double Plug to report
Paramet
power consumption (W) to your controller (hub). The number entered as
value corresponds to the number of seconds. So if 300 is entered by
default, the Double Plug will report energy usage every 300 seconds (5
minutes).
Values: 5 – 2678400. Default set to 300. Size: 4 byte dec.
Auto Turn-On Timer
Parameter 10: Use this parameter to enable or disable the auto turn-on
outlet. If this feature is enabled, the device
timer for
t will automatic
er a fixed period of
connected t
time fr
t in parameter 11).
Values: 0 – timer disabled (def
e: 1 byte dec.
er which you want the
Parameter 11: Use this parameter to se
) outlet to automatically turn on once it
device connected to
. The number entered as value corresponds to the
number of minutes.
Values: 1 – 65535 (minutes). Default set to 60 (minutes). Size: 4 byte dec.
Parameter 14: Enable or disable the auto turn-on timer for the right
(CH2) outlet.
e: 1 byte dec.
Values: 0 – timer disabled (def
er which you want the device connected to
Parameter 15: Se
the right outlet to automatically turn on onc
Values: 1 – 65535 (minutes). Default set to 60 (minutes). Size: 4 byte dec.
Manual Control
Parameter 16: Choose if you want to use the Z-Wave button on the Double
ant to disable this
Plug to turn the outlet
function. If this parameter is set to 0 (disabled), you will only be able to
turn any of the outlet
emotely using your Z-Wave gateway
controller.
ontrol
Values: 0 – manual control disabled for both outlet
enabled for both outlets (default). Size: 1 byte dec.
LED Indicator Mode
Parameter 17: Choose if you want the LED indicators next to each outlet to
, or if you want to disable them.
Values: 0 – LED indicator will display power consumption whenever the
device is plugged in (LED stays on at all times, e
); 1 –
LED indicator will display power consumption whenever the device is ON
ault); 2 – LED indicator will
display the level of power consumption for 5 seconds only whenever the
devic
ator will st
or most of the time); 3
– LED indicator is OFF at all times except for inclusion, exclusion, and
Z-Wave range test.
Size: 1 byte dec.
You can also switch between the LED indicator modes by clicking the ZWave button 6 times quickly.
RANGE TEST TOOL
Voltage (V) Report Frequency
en you want your Double Plug to report
Paramet
voltage to your controller (hub). The number entered as value
corresponds to the number of seconds. So if 300 is entered by default, the
Double Plug will report voltage every 300 seconds (5 minutes).
Values: 5 – 2678400. Default set to 300. Size: 4 byte dec.
Electrical Current (A) Report Frequency
en you want your Double Plug to report
Paramet
electrical current (A) to your controller (hub). The number entered as value
corresponds to the number of seconds. So if 300 is entered by default, the
Double Plug will report current every 300 seconds (5 minutes).
Values: 5 – 2678400. Default set to 300. Size: 4 byte dec.
Overload Protection
Parameter 7: Set the amp level for overload protection to kick in. The
number entered as the value corresponds to the total number of amps the
Double Plug needs to detect across both outlets t
omatically
and send a notification to the hub and associated devices.
Values: 1 – 10 (A). Default set to 10 A.
Size: 1 byte dec.
Auto T
Parameter 8: Use this parameter to enable or disable the auto
outlet. If this feature is enabled, the device
timer for
connected to CH1 outlet will automatic
er a fixed period of
time from being turned on (set in parameter 9).
Values: 0 – timer disabled (def
e: 1 byte dec.
er which you want the
Parameter 9: Use this parameter to se
) outlet to automatic
e it
device connected to
has been turned on. The number entered as value corresponds to the
number of minutes.
Values: 1 – 65535 (minutes). Default set to 60 (minutes). Size: 4 byte dec.
Parameter 12: Enable or disable the auto
(CH2) outlet.
Values: 0 – timer disabled (def
timer for the right
e: 1 byte dec.
er which you want the device connected to
Parameter 13: Se
the right (CH2) outlet to automatic
e it’s been turned on.
Values: 1 – 65535 (minutes). Default set to 60 (minutes). Size: 4 byte dec.
You can easily check if the Double Plug is within your Z-Wave hub’s range:
Press and hold the Z-Wave button for 6 to 8 seconds until the LED
indicator turns violet. The LED indicator will then report signal strength.
Solid green = direct communication with the primary controller is stable
Flashing green = direct communication with the primary controller is
established but signal is weak
Solid orange = stable communication with hub via repeaters
Flashing orange = communication with the primary controller is
established via repeaters but signal is weak
Solid red = communication with the primary controller has failed
Press and release the Z-Wave button to exit testing mode.
NOTE: This function may only be activated once the Double Plug has been
included to a Z-Wave network.
This device requires the following command classes to be supported and
recognized by your Z-Wave controller:
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_ASSOCIATION
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_FIRMWARE_UPDATE_MD
COMMAND_CLASS_MANUFACTURER_SPECIFIC
COMMAND_CLASS_METER
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION
COMMAND_CLASS_MULTI_CHANNEL
COMMAND_CLASS_NOTIFICATION
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_SECURITY_2
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_SWITCH_BINARY
COMMAND_CLASS_TRANSPORT_SERVICE
COMMAND_CLASS_VERSION
COMMAND_CLASS_ZWAVEPLUS_INFO
S2
This product can be included and operated in any Z-Wave network with other
Z-Wave certified devices from other manufacturers and/or other applications.
All non-battery operated nodes within the network will act as repeaters
regardless of vendor to increase reliability of the network.
This product features the latest Security 2 (S2) framework to remove smart
home network hacking risks.
This is an ETL certified device. ETL, just like UL, is a Nationally Recognized
Testing Laboratory. The ETL mark is proof of product compliance to North
American safety standards.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 5.6-c137 79.159768, 2016/08/11-13:24:42
Create Date                     : 2018:12:06 10:59:41+08:00
Creator Tool                    : Adobe Illustrator CC 2017 (Windows)
Modify Date                     : 2018:12:06 11:00:40+08:00
Metadata Date                   : 2018:12:06 11:00:40+08:00
Thumbnail Width                 : 256
Thumbnail Height                : 232
Thumbnail Format                : JPEG
Thumbnail Image                 : (Binary data 34450 bytes, use -b option to extract)
Producer                        : Corel PDF Engine Version 18.1.0.690
Format                          : application/pdf
Creator                         : A Lo
Title                           : 18-11-27-zen25-print-manual-part1.cdr
N Pages                         : 1
Has Visible Transparency        : False
Has Visible Overprint           : False
Max Page Size W                 : 240.000015
Max Page Size H                 : 450.000009
Max Page Size Unit              : Millimeters
Font Name                       : ArialMT, MyriadPro-Regular, SourceSansPro-Light, SourceSansPro-Semibold, SourceSansPro-Regular, SourceSansPro-ExtraLight
Font Family                     : Arial, Myriad Pro, Source Sans Pro, Source Sans Pro, Source Sans Pro, Source Sans Pro
Font Face                       : Regular, Regular, Light, Semibold, Regular, ExtraLight
Font Type                       : Open Type, Open Type, Open Type, Open Type, Open Type, Open Type
Font Version                    : Version 7.00, OTF 1.006;PS 001.000;Core 1.0.23;hotunix 1.28, Version 1.050;PS 1.000;hotconv 1.0.70;makeotf.lib2.5.5900, Version 1.050;PS 1.000;hotconv 1.0.70;makeotf.lib2.5.5900, Version 1.050;PS 1.000;hotconv 1.0.70;makeotf.lib2.5.5900, Version 1.050;PS 1.000;hotconv 1.0.70;makeotf.lib2.5.5900
Font Composite                  : False, False, False, False, False, False
Font File Name                  : arial.ttf, MyriadPro-Regular_0.otf, SourceSansPro-Light_0.otf, SourceSansPro-Semibold_0.otf, SourceSansPro-Regular_0.otf, SourceSansPro-ExtraLight_0.otf
Plate Names                     : Cyan, Magenta, Yellow, Black
Swatch Group Name               : 默认色板组
Swatch Group Type               : 0
Rendition Class                 : proof:pdf
Document ID                     : xmp.did:b86b0e17-3a1b-1345-8bf4-f6f10f360374
Instance ID                     : uuid:a8b9cf59-e2d3-4d5e-9c6c-75fe7c5d693c
Original Document ID            : uuid:849d33ca-6823-498c-8d1e-2ee016bfe9ac
Derived From Instance ID        : uuid:6bb4f3e7-bcef-453e-809e-5c2f4c78f09d
Derived From Document ID        : uuid:849d33ca-6823-498c-8d1e-2ee016bfe9ac
Derived From Original Document ID: uuid:849d33ca-6823-498c-8d1e-2ee016bfe9ac
Derived From Rendition Class    : proof:pdf
History Action                  : saved
History Instance ID             : xmp.iid:b86b0e17-3a1b-1345-8bf4-f6f10f360374
History When                    : 2018:12:06 10:59:42+08:00
History Software Agent          : Adobe Illustrator CC 2017 (Windows)
History Changed                 : /
Page Count                      : 2
AI Creator Version              : 21.0.0
For                             : ic,
Bounding Box                    : 0 -1 1423 1276
AI Build Number                 : 223
AI Color Usage                  : Color
AI Ruler Units                  : Millimeters
AI Color Model                  : CMYK
AI Target Resolution            : 800
AI Num Layers                   : 1
Container Version               : 11
Creator Version                 : 21
Author                          : A Lo
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AQURZW47

Navigation menu