NINGBO DOOYA MECHANIC and ELECTRONIC TECHNOLOGY DM35LE-S DC Electronic Tubular Motor User Manual DM35LE S

NINGBO DOOYA MECHANIC & ELECTRONIC TECHNOLOGY CO., LTD. DC Electronic Tubular Motor DM35LE S

User manual

Download: NINGBO DOOYA MECHANIC and ELECTRONIC TECHNOLOGY DM35LE-S DC Electronic Tubular Motor User Manual DM35LE S
Mirror Download [FCC.gov]NINGBO DOOYA MECHANIC and ELECTRONIC TECHNOLOGY DM35LE-S DC Electronic Tubular Motor User Manual DM35LE S
Document ID2824953
Application IDt/t9UYfSCuPkl98I67W1jg==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize35.61kB (445071 bits)
Date Submitted2015-11-29 00:00:00
Date Available2015-11-29 00:00:00
Creation Date2015-11-26 15:58:19
Producing SoftwareAcrobat Distiller 9.0.0 (Windows)
Document Lastmod2015-11-26 15:59:03
Document TitleDM35LE-S
Document CreatorAdobe Illustrator CS6 (Macintosh)
Document Author: Lai hong tao

Note:When the battery power is low,you can hear the alarm ten "beep" every time the
motor runs. It indicates the battery needs to be charged. Then plug in the charger with
red light.The light turns green when the battery is fully charged.
Signal wire
Tubular MotorDM35LE/S
Specification
85
Functional featuresáąś
Integrated radio control
Setting up+add emitter+delete emitter
Motor direction setting option
Resistance stop function
Jogging&tilt function
Set electronic limit
Set /delete the third limit position
Low standby power
-10
Operating
temperature
Parameter
Rechargeable Description
Type
Rated Torque(N.m)
(A-OO)
Rated speed(RPM)
Rated Voltage(V)
Emission frequency(MHz)
DM35LE/S
The motor has a built-in battery,using the charger to
recharge.You can also use solar panels to charge;when
the battery is low, insert thecharge,charger light shows
3N.m
red light.batteries isfull when the red light turns to green.
28RPM
12V
433.925MHz
1. Please charge the battery and make sure it is fully charged before the first use
2. Don’t operate motors wheuin low wltage alarm:
᰷Motor stop running When the supply voltage is lower than 7 v, and it will restart
again when the voltage is greater than 7.5V
á°¸If the voltage is less than 10v, the motor will alarm for 10 times to prompt it needs
to be charged every timewhen the motor is working.
3. Optratingáąś
á°ˇThe valid interval of the emitter button is 10s,the emitter will quit the set after 10s
á°¸The motor will run or beep for hint,please do the next step after the hint.
4. Set limit positionáąś
á°ˇAfter the up limit and down limit setting,and the up limit down limit and third limit
position are at the same location
᰸After limit setting,with power and memory function;
á°šInto the match-code status 2 minutes later, it will quit out the setting limits status
automatically
á°şIt will delete every memory and restore the factory settings
5. When the motor running without any operation, the maximum running time is 6
minutes,it will stop automatically
6. If the emitterlost,please set up again with new emitter
or
or
Dot-move
Continuous moving
4 Add Emitter
Method one
Press 1s
Run for hint x2
“Di” x3
Press 2s
Run for hint x1
“Di” x1
Display
Emitter adding is ok
Run for hint x2
“Di” x3
Adjust the new
up limit point
Up
Stop
Press 2s
Press 2s
loosen P1
Confirm the new up limit point
or
Press 1s
Press 2s
Down
Setting
Recharger or
solar rechargeable
board port
Channel ᎰᎹ
3
ChannelᎰᎹ
3
3
Method two
3
2OZNO[S)KRR
<
Adjust the new
down limit point
or
Confirm the new down limit point
Press 1s
Run for hint x2
“Di” x3
Press 2s
Emitter adding is ok
Press 1s
is the one already matched code, while emitter
5 Delete one emitter
P2
→P2
Run for hint x1
“Di” x1
Run for hint x2
“Di” x3
Run for hint x1
“Di” x1
3
Press 1s
Press 1s
Press 1s
Note:With the same method,you only can delete the emitter
Run for hint x1
Press 1s
Already set
up, down
limit position
Successful change
the direction
One emitter
is deleted
3
3
①After the up limit and down limit setting, you can set the third limit point between them as the half open position;
2 The reverse of direction setting
The blind
run down
has not
→P2
2 The third limit position setting
1, The third limit position setting
loosen P1
Run for hint x2
“Di” x3
3
Press 1s
Note:Emitter
Press 2s
Set up is ok
Press 2s
Run for hint x1
“Di” x1
3
Press 1s
If you need to reverse the rotateon of the motor controlled by the emitter,please run the reverse of
direction setting(as lists in the second point of the P1 button setting)
“Di” x1
→P2
3
Run for hint x2
“Di” x3
1 Setting up
Run for hint x1
→P2
Run for hint x1
“Di” x1
3
FACTORY MODE
P2
The third limit position
(any position)
Press 2s
P1 BUTTON OPERATION
The motor
stops
Any
position
not the emitter
Functions that can be operated under any mode
1, Activate motor for the first time
Press 1s
Run for hint x1
3 limit position
“Di~~”x1
Activate is ok
Run for hint x1
“Di” x1
1, Enter the limit setting mode
Run for hint x1
“Di” x1
Run for hint x2
“Di” x3
Dot-move
or
Continuous moving
Press 1s
Press 1s
loosen P1
Set up is ok
3
or
Long Press P1
Press 1s
2, The reverse of direction setting
Press 1s
Press 2s
Run for hint x2
á°¸Long press the stop button for 2s,the roller blinds will move to the third limit
2, Set up limit
“Di”x2
Successful change
the direction
( Up→Up+Stop)
The blind
run up
Run for hint x2
“Di” x3
The up
limit point
Confirm the Blind
to stop in the up
limit position
Press 1s
2, The third limit cancel
Long Press P1
(P2→Stop→Stop)
loosen P1
Set up is ok
Run for hint x1
“Di” x1
Press 2s
Run for hint x1
“Di” x1
Run for hint x1
“Di” x1
3, Restore factory settings
Set up is ok
3
Run for hint x3
3, Set down limit
Press 1s
(Down→Stop+Down)
The blind
run down
Run for hint x2
“Di” x3
The down
limit point
Confirm the Blind
to stop in the down
limit position
Set up is ok
Press 1s
3 Dot-move/Continuous moving function switch switch
Set up is ok
Long Press P1
loosen P1
FAULT AND SOLUTION
Run for hint x1
“Di” x1
Run for hint x1
Press 2s
“Di”x3
Press 1s
Dot-move function
FACTORY MODE
Note: After setting up the up and down limit into user mode.
NUMBER
Press 5s
USER MODE
1 Fine-tune up/down limit position
Run for hint x1
“Di” x1
Press 5s
Enter fine-tune
up limit mode
or
Run for hint x1
“Di” x1
Press 5s
Note: Can not be fine-tune up/down limit position at the same time.
Press 5s
when it is working
REASON
PROCESSING METHOD
Press 1s
Notes: Repetitive operation dot-move and continuous moving function switching cycle, under the
dot-move function, according to the upor down button more than 2S release motor linkage operation.
The voltage is low in the
alarm mode
Charge the battery
a,The battery is not activated.
Continuous moving
function
Enter fine-tune
down limit mode
The motor alarms
Run for hint x2
“Di” x3
Run for hint x1
Enter the limit setting mode
PHENOMENON
Press 1s
The motor is
not running
b,The emitter is not matched.
c,If press P1 button for a long
time while with no reaction.may
be the power is short-ciralit or the
ciralit board or the motor is
broken.
a,Activate the motor after fully charged
b,Set up the match code
c,Contact the engineers for after-sales
OPERATION GUIDE
Button specification
FCC STATEMENT
1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may cause
undesired operation.
2. Changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
ǂ Reorient or relocate the receiving antenna.
ǂ Increase the separation between the equipment and receiver.
ǂ Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
ǂ Consult the dealer or an experienced radio/TV technician for help.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Author                          : Lai hong tao
Create Date                     : 2015:11:26 15:58:19+08:00
Modify Date                     : 2015:11:26 15:59:03+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Format                          : application/pdf
Title                           : DM35LE-S
Creator                         : Lai hong tao
Metadata Date                   : 2015:11:26 15:59:03+08:00
Creator Tool                    : Adobe Illustrator CS6 (Macintosh)
Thumbnail Width                 : 256
Thumbnail Height                : 248
Thumbnail Format                : JPEG
Thumbnail Image                 : (Binary data 7664 bytes, use -b option to extract)
Instance ID                     : uuid:fb2d6346-22c7-4978-a175-f0669c8754e3
Document ID                     : xmp.did:E4CF3CCB322068118083C4787C8A81B5
Original Document ID            : uuid:5D20892493BFDB11914A8590D31508C8
Rendition Class                 : proof:pdf
Derived From Instance ID        : uuid:dada9707-e52e-451c-981f-686112b0dd27
Derived From Document ID        : xmp.did:2B6477506A8AE5119F8981EE74242F55
Derived From Original Document ID: uuid:5D20892493BFDB11914A8590D31508C8
Derived From Rendition Class    : proof:pdf
History Action                  : saved, saved
History Instance ID             : xmp.iid:A41ACCC8FF30E511A476CED9E3221461, xmp.iid:E4CF3CCB322068118083C4787C8A81B5
History When                    : 2015:07:23 15:35:35+08:00, 2015:11:14 16:55:55+08:00
History Software Agent          : Adobe Illustrator CS6 (Windows), Adobe Illustrator CS6 (Macintosh)
History Changed                 : /, /
Startup Profile                 : Print
Has Visible Overprint           : False
Has Visible Transparency        : False
N Pages                         : 1
Max Page Size W                 : 419.999859
Max Page Size H                 : 297.000304
Max Page Size Unit              : Millimeters
Font Name                       : Skia-Regular, STXihei, AdobeSongStd-Light, MicrosoftYaHei, RTWSYueGoTrial-Regular, SimHei, Skia, Wingdings-Regular, Z@R834B.tmp
Font Family                     : Skia, 华文黑体, Adobe 宋体 Std, 微软雅黑, 造字工房悦黑体验版, 黑体, Skia, Wingdings, Z@R834B.tmp GBpc-EUC-H
Font Face                       : Regular, 细体, L, Regular, 常规体, Regular, Regular, Regular, GBpc-EUC-H
Font Type                       : TrueType, TrueType, Open Type, Open Type, Open Type, Open Type, TrueType, Open Type, Unknown
Font Version                    : 6.1d3e1, 6.1d4e1, Version 5.010;PS 5.002;hotconv 1.0.57;makeotf.lib2.0.21895, Version 0.75, Version 1.000;PS 1;hotconv 1.0.57;makeotf.lib2.0.21895, Version 5.01, Version 1.0, Version 5.03, Version 5.005;PS 5.004;hotconv 1.0.49;makeotf.lib2.0.15106
Font Composite                  : False, False, False, False, False, False, False, False, False
Font File Name                  : Skia.ttf, 华文细黑.ttf, AdobeSongStd-Light.otf, 微软雅黑.ttf, 造字工坊 悦黑 (5).otf, SimHei.ttf, Skia.ttf, Wingdings.ttf, AdobeHeitiStd-Regular.otf
Plate Names                     : Cyan, Magenta, Yellow, Black
Swatch Groups Group Name        : 明亮
Swatch Groups Group Type        : 1
Swatch Groups Colorants Swatch Name: C=60 M=90 Y=0 K=0
Swatch Groups Colorants Mode    : CMYK
Swatch Groups Colorants Type    : PROCESS
Swatch Groups Colorants Cyan    : 60.000004
Swatch Groups Colorants Magenta : 90.000000
Swatch Groups Colorants Yellow  : 0.003099
Swatch Groups Colorants Black   : 0.003099
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Page Count                      : 3
EXIF Metadata provided by EXIF.tools
FCC ID Filing: VYY-DM35LE-S

Navigation menu