NINGBO DOOYA MECHANIC and ELECTRONIC TECHNOLOGY DM45CEQ-S Tubular motor User Manual DM28CEQ S
NINGBO DOOYA MECHANIC & ELECTRONIC TECHNOLOGY CO., LTD. Tubular motor DM28CEQ S
User manual
Product introduction Tubular MotorDM45CEQ/S Specification Tail insert bracket 85 Functional features: Integrated radio control Setting up + add emitter +delete emitter Motor direction setting option Resistance stop function Jogging&tilt function Set electronic limit Set /delete the third limit position Low standby power -10 Operating temperature Stroke support Rechargeable Description The motor can be charged by both the power adapter or the 12V supply electricity.Is that is rechargeable by solar panel or adaptor when the battery is low. Technical Dare DM45CEQ/S Type 3N.m Rated Torque(N.m) 28RPM Rated speed(RPM) (A-OO) Rated Voltage(V) 12V Emission frequency(MHz) 433.925MHz ttery 12V ba pole Motor Installation ①Driving tube must be close-fitting with crown and drive adapter. ②Choose crown and drive adapter based on the driving tube. Operation note Drive tube Please read the fallowngprecautions befor use: Drive tube 1. Don’t operate motors wheuin low wltage alarm: ① Motor stop running When the supply voltage is lower than 7 v, and it will restart again when the voltage is greater than 7.5V ②If the voltage is less than 10v, the motor will alarm for 10 times to prompt it needs to be charged every timewhen the motor is working. 2. Optrating: ①The valid interval of the emitter button is 10s,the emitter will quit the set after 10s ②The motor will run or beep for hint,please do the next step after the hint. 3. Set limit position: ①After the up limit and down limit setting,and the up limit down limit and third limit position are at the same location ②After limit setting,with power and memory function; ③Into the match-code status 2 minutes later, it will quit out the setting limits status automatically ② Runner ④It will delete every memory and restore the factory settings 4. When the motor running without any operation, the maximum running time is 6 minutes,it will ③ Circlip ① Crown stop automatically 5 If the emitterlost,please set up again with new emitter READING 4 Add Emitter Dot-move Or Or Setting button(P1) Continuous moving Method Press 2s Press 1s one Run for hint x1 Display Run for hint x2 “Di” x3 “Di” x1 Emitter adding is ok Run for hint x2 “Di” x3 Adjust the new up limit point Up Stop Or Press 2s Confirm the new up limit point Down Setting Channel“-” (P1-) Adapter or battery rod P2 Channel“+” (P1+) P2 P2 Lithium Cell 3V Press 1s Method Press 2s Confirm the new down limit point Run for hint x2 “Di” x3 “Di” x1 loosen P1 Press 1s Note:Emitter Press 2s The blind run down Press 1s Already set up, down limit position Successful change the direction The blind stops The third limit position (any position) Run for hint x1 “Di” x1 1, Enter the limit setting mode Press 1s Dot-move Or Continuous moving Press 2s Run for hint x1 “Di” x1 Press 1s The up Press 1s Press 2s Functions that can be operated under any mode “Di~~”x1 Activate is ok Long Press P1 loosen P1 2, The reverse of direction setting Press 1s Run for hint x2 Run for hint x2 “Di” x3 Run for hint x1 “Di” x1 “Di”x2 Press 1s Run for hint x1 Set up is ok Run for hint x3 Set up is ok Long Press P1 Dot-move function NUMBER Press 1s USER MODE 1 Fine-tune up/down limit position Run for hint x1 Enter the limit setting mode Run for hint x1 “Di” x1 Enter fine-tune up limit mode Or Run for hint x1 “Di” x1 Press 5s Note: Can not be fine-tune up/down limit position at the same time. Enter fine-tune down limit mode Press 5s loosen P1 FAULT AND SOLUTION and down limit into user mode. Press 5s “Di”x3 Press 1s Run for hint x1 “Di” x1 Press 2s loosen P1 3, Restore factory settings Run for hint x1 “Di” x1 3 Dot-move/Continuous moving function switch switch Set up is ok Confirm the Blind to stop in the down limit position Note: After setting up the up Run for hint x1 “Di” x1 Press 1s The down limit point Long Press P1 (P2→Stop→Stop) P2 (Down→Stop+Down) The blind run down 2, The third limit cancel Set up is ok Confirm the Blind to stop in the up limit position 3, Set down limit not the emitter Successful change the direction limit point Press 5s Press 1s Run for hint x1 Run for hint x2 “Di” x3 ②Long press the stop button for 2s,the roller blinds will move to the third limit Run for hint x2 “Di” x3 The blind run up One emitter is deleted P2 (Up→Up+Stop) 2, Set up limit Press 1s Run for hint x2 “Di” x3 1, Activate motor for the first time Set up is ok Press 1s has not →P2 Run for hint x1 “Di” x1 P1 BUTTON OPERATION Press 1s P2 Press 1s →P2 P2 3 Limit position Press 1s P2 P2 Any position Press 2s Or Press 1s Note:With the same method,you only can delete the emitter Run for hint x1 Emitter adding is ok is the one already matched code, while emitter Run for hint x1 “Di” x1 (P2→Stop→Stop) Run for hint x2 “Di” x3 P2 Press 1s 5 Delete one emitter ①After the up limit and down limit setting, you can set the third limit point between them as the half open position; 2 The reverse of direction setting Run for hint x1 “Di” x1 2 The third limit position setting 1, The third limit position setting Press 2s →P2 P2 Set up is ok Press 2s →P2 Press 1s 1 Setting up Run for hint x1 P2 P2 Run for hint x2 “Di” x3 或 If you need to reverse the rotateon of the motor controlled by the emitter,please run the reverse of direction setting(as lists in the second point of the P1 button setting) two Run for hint x1 “Di” x1 Adjust the new down limit point FACTORY MODE Press 2s loosen P1 Run for hint x2 “Di” x3 Continuous moving function Press 1s Notes: Repetitive operation dot-move and continuous moving function switching cycle, under the dot-move according to the upor down button more than 2S release motor linkage operation. function, PHENOMENON The motor alarms when it is working Motor can’t running REASON The voltage is low in the alarm mode a,The battery is not activated. b,Theemitter is not matched. c,If press P1 button for a PROCESSING METHOD Charge the battery a,Activate the motor after fully charged b,Set up the match code c,Contact the engineers for after-sales. OPERATION GUIDE Button specification 电 机 操 作 指 南 FCC STATEMENT 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Create Date : 2015:11:14 16:51:05+08:00 Creator : Adobe Illustrator CS6 (Windows) Modify Date : 2015:11:16 10:08:25+08:00 Producer : Adobe PDF library 10.01 Title : DM28CEQ-S Warning : Root object (1 0 obj) not found at 2113EXIF Metadata provided by EXIF.tools