 - 2 -            ⓒ Copyright 2006 NITGEN Co., Ltd.    All rights reserved   NITGEN Customer Service Center Tel. 080-060-1600 (Toll Free) Fax. +82-31-451-6722 E-mail: customer@nitgen.com URL: http://www.nitgen.com  Reproduction of part or all of the contents in any form is prohibited other than in accordance with the permissions.  Product  specification  can  be  changed  and  upgraded  to  improve functionality without prior notice.   NITGEN, NITGEN logo are registered trademark of NITGEN.
 - 3 -  Table of Contents CHAPTER 1. INTRODUCTION .................................................................... 5 1.1 Product Introduction ......................................................................................... 5 1.2 Product Features and Specification .................................................................. 7 CHAPTER 2. HOW TO USE ....................................................................... 12 2.1 Detailed Product Parts .................................................................................... 12 2.2 LCD Screen Layout ....................................................................................... 14 2.3 Fingerprint Use ................................................................................................ 15 2.4 Authentication .................................................................................................. 16 2.4.1Fingerprint ................................................................................................... 16 2.4.2Password ......................................................................................................  21 2.4.3RF Card (optional) ....................................................................................... 22 2.4.3Others: Automatic Attendance Mode ........................................................... 23 CHAPTER 3. ENVIRONMENT SETTING ................................................... 24 3.1 Menu Composition .......................................................................................... 24 3.2 Entering into Menu ......................................................................................... 27 3.3 Basic Menu ....................................................................................................... 28 3.4 Detailed Menu .................................................................................................. 30 3.4.1 User Management .......................................................................................  30
 - 4 - 3.4.2 Fingerprint Sensor Setting .......................................................................... 45 3.4.3 UI (User Interface) Setting ......................................................................... 54 3.4.4 System Setting ............................................................................................ 57 3.4.5  Network Setting ....................................................................................... 66 3.4.6  Cofirmation of Terminal Information ...................................................... 72 3.4.7 Factory Default Setting ............................................................................... 74 APPENDIX 1: NETWORK CONNECTION ERROR AND SOLUTIONS ..... 78 APPENDIX 2: TERMINAL INITIALIZATION ERROR AND SOLUTIONS .. 80 APPENDIX 3: LAW AND REGULATION .................................................... 81 APPENDIX 4: WIEGAND PROTOCOL FORMAT ...................................... 82 APPENDIX 5 : EMERGENCY SCREEN .....................................................  84
 - 5 - Chapter 1. Introduction  1.1 Product Introduction    Overview The use of biometrics system continuously increases in various authentication systems and in areas that require a higher level of security because of its ease of use and economical benefits. Among a number of biometrics system, a fingerprint recognition system is not only easy to use but also enables economical product development. It takes up the most part of the market as it allows a wide variety of application. NITGEN, a leader in the fingerprint recognition area, has provided fingerprint recognition  solutions  for  the  management  of  PC  security, knowledge,  safe,  access  control,  electronic  payment  and financial clearings. Continuous R&D activities and  quality management ensure that NITGEN meets evolving needs and demands of the market and the customers. NITGEN access control system is a culmination of world-renowned technologies  from  NITGEN  including  fingerprint  recognition algorithms,  optical  sensor,  embedded  design  and  software applications. Unlike legacy access control systems that use only password and ID card, it provides the ease of use and tight security with no risk of forgetting password, stolen cards or forgery. The system is designed to provide maximum operational efficiency over the network by enabling remote monitoring on terminals that have been independent so far.  NITGEN access control system allows various combinations of FR card, password and fingerprints. It also meets the common set of  requirements  and  special  needs  in  the  corporate  and
 - 6 - government sectors with such functions as shortened ID, 1:N matching and voice guidelines.  The manual gives in-depth explanation as to how to use NITGEN access control terminal (NAC-2500LM).    System Components                    Main Features Server PC 1. Server S/W : Access Sever 2. Terminal  communication,  log  data collection 3. user information & log DB 4. authentication  Client PC  1. Client S/W : Remote Manager/Monitor Network Server PC Terminal  Client PC NAC-2500 Access Server Remote Manager Remote Monitor
 - 7 - 2. user registration and other management  3. Terminal status and event monitoring Terminal ( NAC-2500LM ) 1. user check and authentication  2. access door control     NITGEN access control terminal(NAC-2500LM) can be used alone for full functionality or can be used in connection with the network together with admin programs (Access Server, Remote Manager, Remote Monitor) in order to reduce the number of terminals and to ensure an easier and a more effective management. Server S/Wand Client S/W can be placed within one PC.   1.2 Product Features and Specification    Product Features  NITGEN access control system (NAC-2500LM) has the following features. ① access control and management on small & medium number of users ②  a  combination  of  various  authentication  methods (fingerprint, password, RF card) ③  network-based  access  control  on  terminals  for  multiple users ④ easy remote management on the system (Server/Client PC can be separated) ⑤  view  on  user’s  access  history  and  various  additional functions
 - 8 - ⑥ real-time access monitoring ⑦ access control by period and time ⑧  SDK  (S/W  Developer’s  Kit)  for  the  development  of application programs such as attendance management program (separate) ⑨ high-speed 1:N authentication ⑩ enhanced user-friendliness and ease of use (shortened ID, Auto-on) ⑪  perfectly  verifies  the  authorized  user  with  its  fake fingerprint identification function     System Specification (Connected to Server)  Specification Details Connection Terminal Maximum 255 units Remote Management  8 concurrent accesses to server # of Users to be Registered 10,000 users Network  TCP/IP, 10M bps Authentication Type fingerprint,  password,  RF  card (optional) Authentication Speed 1:1 mode: less than 1 second 1:N mode: refer to Application Note   Note) Enterprise version software  Unlimited  terminal  access.  (Proportional  to  system
 - 9 - capacity)  Unlimited number of registered users. (Proportional to system capacity)  1:1 server authentication only.     Detailed Specification: Terminal Function  Spec. Display Type  128 * 32 Dots LCD Language  Default: Korean, English Additional Type A:  Japanese,  Chinese,  Spanish French, Thai, Indonesian Additional Type B: Polish, Farsi, Malay, Hebrew , Vietnamese(voice  only)  , Portuguese Sensor Model  OPP03 LFD Type  Optical Resolution  500 DPI Additional  Auto on / Latent Image Check Live Finger Detection Authentication Speed  1:1 mode: less than 1 sec 1:N mode: Application Note Algorithm  FRR: less than 0.1%,  FAR: less than 0.001% # of registered users  Terminal  2000(1 fingerprints per user) 1000(2 fingerprints per user) Communication  TCP/IP  10 base-T Ethernet  (optional)
 - 10 - RS-485  Max. 115200bps (Custom requirement) Wiegand  1. Input: provided with the use of external card reader 2. Output  Access Controller mode: Facility Code and ID  Reader mode: Values  read  from  Card reader ※4 characters only for ID Size  Case  90 (W)* 200 (L)* 48 (H) mm Door support  Dead Bolt / Strike / EM Lock / auto door Power  Adapter 1  In: AC 100V ~ 240V, 50/60 Hz Out: DC 12V, 3A (24V OK) Adapter 2  In: AC 100V ~ 240V, 50/60 Hz Out: DC 5V, 3A  Additional Function Guidelines recorded in voice Downloadable logo/firmware ID length (4 ~ 15 digits) Authentication results to be displayed in LED Optional Network Board Door Control Board RF Module  [13.56MHz Mifare(10M 93.5 ㏈㎶/m )]
 - 11 - Temperature Storage   -25℃ ~ 65℃  Operation  -20℃  ~  60℃  (with  no  dew condensation) Humidity Storage   15% ~ 90% RH Operation  25% ~ 85% RH    WARNING  THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS : (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEIVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.        NOTE : THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.
 - 12 - Chapter 2. How to Use  2.1 Detailed Product Parts                    ① LCD: All activities are displayed with text message.  ② Key pad: Used for ID input and environment setting. Details are as follows.   Key  Description 0 ~ 9  To type in numbers *, # To move a curser up and down for menu selection and to change direction. *(Backward), #(Forward) ① ② ③ ⑤④ ⑥
 - 13 - Enter  To complete ID type-in or environment setting. Delete  To erase typed-in numbers one by one or to move to higher level in menu. Menu  To set or change an environment. F1 ~ F4 User-customizable buttons that can be used for attendance  management  including arrival/leave/go-out/return. F1~F4 can be set freely depending on software requirements. SHIFT  Reserved AUX  Reserved  ③ Speaker: Used for recorded voice guidelines and warnings. ④ LED lamp: Showing operations of the terminal. Each lamp represents the followings.  Function  Operation  Color Authentication To  display  the  results  of authentication.  Green  for success and red for failure. Green/red Power  To display power status wit LED on for power on.   Red Network To display network connection with  LED  on  for  network connected. Green   ⑤ fingerprint input sensor and Auto-On switch: To contact and
 - 14 - take fingerprint. With no operation of key pad, fingerprint will be automatically input by touching the fingerprint input sensor with a  finger. It  is  a cutting-edge fingerprint sensor  that prevents use of fake fingerprints  ⑥ Reset switch: To reset the terminal if the terminal is not in normal operation unexpectedly.  2.2 LCD Screen Layout    Initial Screen of Terminal The  initial  screen  of  terminal  is  as  follows.  The  bottom  line displays current date and time.       P  ㅣ  a  c  e    Y  o  u  r    F  P       1 3 : 4 6 : 1 7
 - 15 - 2.3 Fingerprint Use  To  prevent  authentication  errors  from  occurring  during  the registration and authentication of fingerprint, please follow the methods below.   ①  To maximize the contact area and press the surface evenly. On  a  scale  of  0  to  100%  (0%:  minimum  power  100%: maximum  power),  please  press  the  surface  with approximately 50%~70% power.         ② Please place the core of fingerprint shape in the center. In general, the core of fingerprint is located in the same line with half moon in user’ s fingernail and therefore, place the half moon in the center of fingerprint sensor.
 - 16 - 2.4 Authentication  NITGEN Access Control System recognizes fingerprint, password, and  RF  CARD  (optional) for  authentication.  Users  can  get authentication by freely choosing any method depending on their own environment.  2.4.1Fingerprint  The following methods can be used to check access right with fingerprints.  • 1:1 Match It is to input fingerprint after feeding an ID that is already registered. It matches input fingerprint with an already registered  fingerprint  for  a  specific  ID  on  a  1:1  basis.  The time required for authentication for 1:1 match is substantially short regardless of the number of users. There is no need to set  the  mode  in  a  system.  Authentication  procedure  begins when fingerprint is input after ID is typed in.    First, please input user ID and then press ENTER or place your finger on a sensor if Auto-ON is enabled.   I N P U T  I D :       1 2 3 4            P  l  a  c  e    Y  o  u  r    F  P
 - 17 -   • 1:N Match It  does  authentication  only  with  a  registered  fingerprint.  The authentication  procedure  is  simple  but  it  can  take  relatively longer time than the 1:1 match when a number of users try to access the system. There is no need to set the mode in a system.  A  simple  input  of  fingerprint  will  initiate  the authentication process. If it takes too long for 1:N authentication due to too many users, please try ‘ 1:N time set’  in which authentication  is  retried  by  typing  in  ID  when  authentication  is not completed within in the set time. Please refer to the following details for ‘ 1:N authentication time.’        • Authentication with Shortened ID (SID) Users  can  select  ID  with  characters  between  4~15 depending  on  default  setting.  Shortened  authentication  is designed to simplify an ID input procedure in which the authentication begins with only a couple of characters from a     S u c c e s s !                         P  l  a  c  e    Y  o  u  r    F  P                        S u c c e s s !
 - 18 - set ID to be input. For example, if a user uses an ID of 1234 567,  the 1:N  match against any  IDs  starting with  12xxxxx is initiated in the system when the user inputs 12 followed by a fingerprint. There is no need to set the mode in a system.         • Authentication for attendance mode It  does  authentication  by  using  function  keys  (F1~F4). Before  trying  authentication,  please  press  an  appropriate function key and proceed with authentication.  In  this  case, the  result  associated  with  the pressed  function key  remains in  log  history  which  can  be  used  for  attendance  data.  For example, if a user presses F1 and then inputs an ID, the ID+F1 remain in log history. Also, if a user presses F1 only and then proceeds with 1:N authentication, an appropriate ID is searched to remain ‘ ID+F1’  record.    The following shows an LCD display when pressing F1. I N P U T  I D :       1               P  l  a  c  e    Y  o  u  r    F  P                        S u c c e s s !                         F  1  -  I  N  P  U  T    I  D  :
 - 19 -      * In order to use attendance mode, the option of terminal is set in by Menu-> system options(4) -> Function mode(4) -> T&A  • Expanded attendance mode It  does  authentication  by  using  extended  function  keys (F11~F19, F21~F29, F31~F39, F41~F49) Before  trying  authentication,  please  press  an  appropriate function key and select approprating number with a Left key (*) or a Right Key (#). In case of pressing the left key, it is decressed  the  number  of  function.  And  in  case  of  pressing Left Key (*),    it is incressed the number of function displayed in LCD.  * Right key input (#)  P  l  a  c  e    Y  o  u  r    F  P                        S u c c e s s !                         F  1  -  I  N  P  U  T    I  D  :       1 2 3 4            F  1  1  -  I  N  P  U  T    I  D  :     1 2 3 4
 - 20 -  * Leftt key input (*)  To set or delete the expanded attendance mode, please take the following steps.   1) To set the mode: Please set Menu->System Option (4) -> Function Mode (4) -> T&A -> Auto T&A -> expanded T&A -> YES   2) To delete the mode: Please set Menu->System Option (4) -> Function Mode (4) -> T&A -> Auto T&A -> expanded -> NO  • Function key Display  You  can  choose  the  display  message  when  press  the function key. The option is set in Menu -> UI Option(3) -> FuncKey Disp -> Mode1 or Mode2     Option  F1 KEY  F2 KEY  F3 KEY  F4 KEY Off  F1  F2  F3  F4 Mode1  Clock In  Clock Out Absense  Return Mode2  Check In Check Out F3  F4  If the option of function key display is set by mode1, Follwing message is displayed when you press the F1 key.  C  l  o  c  k   I  n  :   1 2         F  1  9  -  I  N  P  U  T    I  D  :     1 2 3 4
 - 21 -  * * In order to use Function key display, the option of terminal is  set    by  Menu->  system  options(4)  ->  Function  mode(4) -> T&A    • Authentication failure message  The following messages are displayed depending on authentication method and causes of failure.   An error message for matching failure.    The following message is displayed when image capturing is failed. When the message is displayed, please check if your fingerprint is too dry or too wet.    2.4.2Password  It checks the right to access by using 4~8 digit password and it  is  used  in  special  occasions  including  damaged fingerprint.    M a t c h i N g   E r r o r                 T i m e o u T !
 - 22 -   Password can be set up to 8 digits.    2.4.3RF Card (optional)  User identity is confirmed through a RF CARD that he or she has. By registering RF CARD numbers in the system, the use of lost or stolen card can be prevented. To initiate authentication by using a RF CARD, you can either contact RF card when the initial screen appears or contact RF card when the following message is displayed after typing in user ID.  Please place your card in front of the fingerprint sensor when the following message appears.   The following message appears in case of success.    I N P U T  I D :       1 2 3 4            I  N  P  U  T    P  A  s  s  w  d       : * * * * *          C  o  n  t  a  c  t    R  F    c  a  r  d O n  S e n s o r           S u c c e s s !
 - 23 - 2.4.3Others: Automatic Attendance Mode  The result of attendance can automatically remain in log history only with general 1:N authentication. When a specific attendance status is repeated many times, the user does not need to take trouble to press the same function key (F1~F4) each time.  In an automatic attendance mode, the initial screen changes as follows and when the 1:N match is tried, the authentication result is automatically attached with the relevant attendance status.    To set or delete the automatic attendance mode, please take the following steps.   1) To set the mode: Please set Menu->System Option (4) -> Function Mode (4) -> T&A -> Auto T&A -> YES   2) To delete the mode: Please set Menu->System Option (4) -> Function Mode (4) -> T&A -> Auto T&A -> NO    2.4.4 Others : Free Scan(1:1 match only)  In free scan mode (1:1match only), 1:N match and Authentication with Shortened ID are forbidden. The option is set by MENU -> FP OPTION (2) -> Free Scan Mode (7) -> YES or NO It’s possible to use all of authentications (1:1, 1:N, SID match), if the option is set in“NO”.  F  1  -  I  N  P  U  T    I  D  :       1 2 3 4
 - 24 -  Chapter 3. Environment Setting  3.1 Menu Composition  The  following  table  shows  the  entire  menu  composition  of terminal. The menu is helpful in setting initial environment, user registration, fingerprint recognition device, and network. To use the menu, please press the menu button on the key pad of Terminal. Please refer to chapter 3 for user registration, information change,  user  deletion,  number  of  registered  users  and version-related information.   Higher menu  Detailed Menu  Sub menu  1  User Management 1User registration   2User info change 3User deletion 4Deletion of all users2  Fingerprint sensor setting 1Sensor brightness  (1~100) 2Security level  11:1 mode 21:N mode (Please try menu 3 times after setting number 1) 3Capture mode   4Time setting for fingerprint input 5AUTO-ON setting
 - 25 - 61:N time setting  1Whether to use 1:N time setting or not 2Time setting   (“time setting” possible only when it is on) 7Free Scan mode   3   UI setting   1Language   2Voice guideline 3Button tone 4Function Key Disp4  System Setting    1Log storing   2RF card 3WIEGAND  1OFF 226BIT 334BIT 4Function key setting 1AC 2T&A (Auto T&A) 5Authentication mode  6Time setting   7Terminal mode 8Time zone   5  Network  1Terminal ID   2TCP/IP  1DHCP yes or no? 2Terminal IP 3Sebnet Mask 4Gateway 5Server IP 3Time limit   4Port setting 6  Information  1Number of users
 - 26 - 2Firmware version 7  Factory default  1DB Format   2Factory format 3Number of registered fingerprints 4Number of characters in ID 5Reset terminal
 - 27 -  3.2 Entering into Menu    Master Authentication  At the time of initial installation of terminals, environment can be set without master’s authentication. However, master authentication  is  a  must  in  order  to  change  environment settings after master setting. To view menu, please press a master  button which  will  display  the  following  screen for master authentication. You can see the menu after inputting the ID  of  master  and  conduction  authentication  with  selected authentication methods including fingerprint, password and RF.     I  N  P  U  T    M  A  S  T  E  R    I  D 1 2 3 4              For an independently installed terminal that does not use any network, an initially registered user will be automatically registered as master. Please refer to chapter  3  “user  registration”  for  detailed registration  method.  During  the  initial  user registration, default values at “authority setting” will be set as master.   When using network, an initially registered user can choose between either a master or a normal user. It is the same as a registration process for normal users.
 - 28 -    Result Display  The following message is displayed if master authentication is successful. After one  second, you  can enter into  the menu. However, you will get a failure message when the authentication is not successful which is same as the failure message for general authentication failure.      3.3 Basic Menu  The following screen is enabled after pressing a menu button at the initial screen of terminal and if master authentication is successful. You can choose basic menu by pressing #, * keys or number keys.       The following explains the basic menu. If you press ENTER in the basic menu, you can move to detailed menu which is a sub menu of each basic menu. Please press DELETE to go back to the basic menu     S u c c e s s !                             [ M E N U ]        1   2   3   4   5   6   7
 - 29 - from detailed menu or to go back to the initial screen from the basic menu.   The higher menu has the following 7 categories.            U  s  e  r    M  a  n  a  g  e  r      1    2    3    4    5    6    7      F P  O p t i o n     1  2    3    4    5    6    7      U I  O p t i o n     1  2  3    4    5    6    7     S  y  s  t  e  m    O  p  t  i  o  n     1   2   3   4    5    6    7       N e t w o r k       1   2   3   4   5    6    7       I n f o r m a t i o n      1   2   3   4   5   6    7       F a c t o r y   I n i t    1   2   3   4   5   6   7
 - 30 -  3.4 Detailed Menu  3.4.1 User Management  The  user  management  menu  manages  database  in  which  user information is stored. It is accessible only through master’s authentication (see Master Authentication in chapter 2.) Four sub menus are provided including user registration, change and deletion. Use direction buttons and choose ENTER.      3.4.1.1 User Registration    It is designed to store the information of users into database who will use the access controller. Please register the user with the following procedures after master authentication.   [ U s e r   M a n a g e r ]   1  2  3  4          R e g i s t e r   U s e r   1  2  3  4
 - 31 -   1) To input user ID When  user  registration  menu  is  selected,  you  will  see  the following screen that waits for the input of user ID. After typing in an appropriate user ID, please press ENTER. If the same ID already exists, a failure message will be displayed and the system goes back to a previous menu.        2) Authority setting The following explains how to set user authority between I N P U T  I D :       1 2 3 4             User  registration  is  conducted  in  terminal  when  the terminal mode is set at SO. It can be conducted either in server or in terminal if the mode is set at NL. Note that terminal registration is possible if network is in normal operation under the NL mode, but is not possible if network is disconnected.   To change SO mode into NL mode, user DB in the terminal should all be erased and re-registered. To correct ID during typing, please use a delete button. It will erase characters one by one or will go back to a higher menu when no character is input.
 - 32 - normal user and master. Please use a directional key and press ENTER to finish.   • Normal user: no right to terminal management with access authority only via identification.   • Master: terminal manager who has not only the right to access but also user DB management, environment setting and other menu.       3) Choice on Authentication Please  choose  the  authentication  mode  of  users  among fingerprint, password, RF CARD, and other combinations. Please use a directional key and press ENTER to finish.      U s e r  T y p e       N  O  R  M  A  L  /  M  A  S  T  E  R     A  u  t  h  e  n  .    M  o  d  e       1  2  3  4  5  6  7  8  9  10           If  RF  is  not  selected  during  system  setting, authentication  with  RF  will  not  be  displayed  in authentication mode screen.
 - 33 -    • How to use by authentication mode  ※Legend: FP(fingerprint), PW(password), RF(RF CARD), Enter()             “/”(OR combination), “&”(AND combination) Mode  Description fingerprint  Fingerprint only for authentication. ① ID + fingerprint (1:1 match) ② fingerprint (1:N match) password  Password only for authentication. ① ID +  + PW +  RF  RF CARD only for authentication. ① RF fingerprint/password Fingerprint or  password for  authentication with priority on fingerprint.  Password authentication is re-tried if ID is already  input  with  a  failed  fingerprint authentication. However, authentication is failed if  ID  is not  already input with  a failed fingerprint authentication.  ① ID + FP (FP failure, PW +) ② FP (FP failure = authentication failure) fingerprint/RF Fingerprint or RF CARD for authentication with priority on fingerprint.  RF CARD authentication is re-tried if ID is already  input  with  a  failed  fingerprint authentication.  However,  authentication  is failed if ID is not already input with a failed
 - 34 - fingerprint authentication.  ① ID + FP (FP failure, RF) ② FP (FP failure = authentication failure) ③ RF password/RF  Password or RF CARD for authentication.  ① RF ② ID +  + PW +  (PW failure, RF) fingerprint& password  Both fingerprint and password authentication should be a success. Note that ID should be typed in first before fingerprint.  ① FP + PW +  ② ID + FP + PW +  fingerprint& RF Both fingerprint and RF CARD authentication should  be  a  success  to  complete authentication. It has the following three options.  ① RF + FP ② FP(1:N match) + RF ③ ID + FP + RF password& RF  Both  password  and  RF  CARD  authentication should  be  a  success  to  complete authentication. ① RF + PW +  ② ID +  + PW +  + RF fingerprint& password&  RF Fingerprint, password, RF CARD authentication should  all  be  a  success  to  complete authentication. ① FP + PW +  + RF ② ID + FP + PW +  + RF ③ RF +  + FP + PW + 
 - 35 -     From the above table of authentication methods, shortened ID authentication can be used for fingerprint authentication (see 1.6 Authentication of chapter 1.)   4) Fingerprint input  User’s  fingerprint  is  input  if  fingerprint  or fingerprint-included  authentication  is  selected. Fingerprints will be input twice. Please lift your finger after the first time and then place it again for the second time.   Place your finger for fingerprint input.    Please remove your finger from fingerprint sensor when the following message is displayed.    Please place your finger again.    F P             1  2  3  4  5  6  7  8  9  10          P l a c e  F P 1                      R e m o v e  F P
 - 36 -   You will get a success message for successful fingerprint input and will get a failure message for failed fingerprint input. In case of failure, you will go back to the initial registration screen.       The  NAC-2500  includes  a  routine  that  checks  similar fingerprints during registration. If similar fingerprints are  registered  already,  the  following  message  will  be displayed. In this case, it is convenient to use a different finger for fingerprint registration.     5) Password input  User  password  is  input  when  password  or  password-included authentication is selected. Your password can be between 4~8 P l a c e  F P 2                          S u c c e s s !                           D  u  b    C  h  e  c  k    E  r  r
 - 37 - digits.    For security reason, the input password will be displayed as 『*』.   The input password is confirmed.  You will get a success message for successful password input and will get a failure message for failed password input. In case of failure, you will go back to the initial registration screen.    6) RF CARD input When RF CARD is selected at System Setting, users can be registered by using RF CARD. Please approach user’s RF CARD near  fingerprint  sensor.  Make  sure  that  RF  option  is  P W             1  2  3  4  5  6  7  8  9  10          I  N  P  U  T    P  a  S  s  w  d    1   : * * * * *          I  N  P  U  T    P  a  S  s  w  d    2   : * * * * *              S u c C e s S !
 - 38 - selected during terminal environment setting.     You will get a success message for successful RF CARD input and will get a failure message for failed RF CARD input. In case of failure, you will go back to the initial registration screen.    7) Other Registration Methods  The previous methods can be freely combined for registration. Please refer to the following.  1.fingerprint 2. Password 3.RF  4.fingerprint /password 5. Fingerprint/ RF 6. Password / RF 7. Fingerprint & password 8. Fingerprint & RF 9. Password & RF 10. Fingerprint & password & RF    R F             1  2  3  4  5  6  7  8  9  10          C  o  n  t  a  c  t    R  F    c  a  r  d O n  S e n s o R           S u c c e s s !
 - 39 - 3.4.1.2 User Information Change  It is designed to change user information including changes in fingerprint,  password,  RF  CARD,  Authentication,  and authority.   When choosing『user information change』, the following screen will be displayed to input user ID.    After  inputting  ID  and  pressing  ENTER,  the  following changeable items will be displayed. Please use a directional key and press ENTER to finish.     1) Fingerprint change  The menu is designed to change registered fingerprint for individual  registered  users.  Just  like  fingerprint registration, fingerprints should be input twice. Make sure that you should remove your finger after the first time and   M o d i F y   U s e r       1  2  3  4        I N P U T  I D :       1 2 3 4              M o d i f y   U s e r       1  2  3  4  5
 - 40 - place it again for the second time.    Please input fingerprint.   Please remove your finger from fingerprint sensor when the following screen appears.     Please input the same fingerprint again.    You will get a success message for successful fingerprint input and will get a failure message for failed fingerprint input. In case of failure, you will go back to the initial registration screen.   F P              1  2  3  4  5      P l a c e  F P 1                      R e m o v e  F P                      P l a c c  F P 2                          S u c c e s s !
 - 41 -  Just like fingerprint registration, similar fingerprints are checked.    2) Authentication method change    Please selected authentication method that will be changed.  1.Fingerprint 2.password 3.RF  4.fingerprint / password 5. Fingerprint/RF 6. Password / RF 7. Fingerprint & password 8. Fingerprint & RF 9. Password & RF 10. Fingerprint & password & RF  3) Authority change    It changes the authority of individual registered users. User authority consists of normal and master user. Master users   D  u  b    C  h  e  c  k    E  r  r                    A u t h e n . M o d e       1  2  3  4  5        U  s  e  r    T  y  p  e            1  2  3  4  5
 - 42 - can  enter  into  menu  to  do  various  terminal  controls. Therefore, it is desirable to allocate master user authority only to a limited number of users.     4) Password change  Registered password can be changed.   Please input new password.  Please input the password again.    You will get a success message for successful input and will get a failure message for failed input. In case of failure, you will go back to the initial registration screen.  3) RF CARD change U s e r  T y p e       N  O  R  M  A  L  /  M  A  S  T  E  R      P a s s W o r d         1   2   3   4  5      I  N  P  U  T    P  a  s  s  w  d    1   :               I  N  P  U  T    P  a  s  s  w  d    2   :
 - 43 -  RF CARD of individual registered users can be changed.     Please contact the RF CARD when the following message appears.   You will get a success message for successful input and will get a failure message for failed input. In case of failure, you will go back to the initial registration screen.      3.4.1.3 User Deletion    Registered users can be deleted and deleted.   Please input user ID to be delete. When the ID does not exist,   C h a n g e   R F            1   2   3   4   5      C  o  n  t  a  c  t    R  F    c  a  r  D O n  S e N s o r           S u c c e s s !                           D e l e t e   U s e r       1  2  3  4
 - 44 - the process fails and goes back to the initial screen.   Please confirm the selection.   The following message appears for successful deletion.      3.4.1.4 Deletion of All Users  All users can be deleted at once.     I N P U T  I D :                      A  r  e    Y  o  u    S  u  r  e  ?      Y  E  S / N O             S u c c e s s !                           D e l e t e   A l l          1   2   3   4         Please be careful as it will delete all registered users within a terminal.
 - 45 - When 『yes』is selected, the deleting procedure begins.        3.4.2 Fingerprint Sensor Setting  As a second option underneath the main menu, there is an option to select fingerprint sensor. You can choose the following in the main menu.      There are the following 7 categories within a sub menu.   3.4.2.1 Brightness  The first category is sensor brightness. It is recommended A  r  e    Y  o  u    S  u  r  e  ?      Y  E  S / N O             S u c C e s s !                            F P  O p t i o n     1  2    3    4    5    6    7      F P  O p t i o n      1   2   3   4   5   6   7
 - 46 - that the initial value is not changed.        3.4.2.2 Security Level  The security level will be set for 1:1 match. It is not possible to set security level for 1:N match and when needed, only a NITGEN after sales engineer can set the level.    Please press ENTER to go into a sub menu.   • You can set the security level for 1:1 mode by choosing 1. However, it is recommended that the value is not changed.     B r i g h t n e s s         1    2    3    4    5    6    7     B r i g h t n e s s          ( 0 - 1 0 0 ) : 5 5          S e c u . L e v e l         1  2    3    4    5    6    7     S e c u . L e v e l         1
 - 47 -          1 : 1  M o d e       ( 1 - 9 ) :  5            S u c c e s s !
 - 48 -  3.4.2.3 Capture Mode  The  product  provides  four  capture  modes  for  fingerprint including  normal,  latent,  intelli  and  LFD(Live  Finger Detection). The normal mode provides the highest speed. The latent capture is relatively slower but can capture latent fingerprints  on  the  surface  of  a  sensor.  The  Intelli  is relatively slower in speed, yet it analyzes the fingerprints of  users to  capture the optimal fingerprint image  the LFD provides that prevents use of fake fingerprints.   The initial setting is  『LFD』. Please use a directional key and press ENTER to finish.    C a p t u r e   M o d e     1  2  3    4    5    6    7    Please press ENTER to go into a sub menu.    N o r m a l / L a t e n t  /  I  n  t  e  l  l  i  /  L  F  D        When you choose to use LFD, the following submenu will be additionally displayed to select Live Finger Detection Level.  The initial setting is  『LOW』 However, the  authentication  ratio may deteriorate if the value is set by HIGH  L F D   L e v e l        L  O  W  /  M  I  D  /  H  I  G  H
 - 49 -   The  following message  will  be  displayed  when  an  appropriate function is successfully selected.     S u c c e s s !
 - 50 -  3.4.2.4 Fingerprint Input Time (1 ~ 30 seconds)  It is to set time limit for fingerprint input to a terminal. If a fingerprint is not input within the selected time, a failure message will be displayed to encourage a re-try.  Please press ENTER to go into a sub menu.    S  e  n  s  o  r    T  i  m  e  o  u  t   1   2   3   4    5    6    7    The values can vary between 1~30.  The default value is 『5 seconds』. Please type in an appropriate time with number keys and press ENTER to finish.     S  e  n  s  o  r    T  i  m  e  o  u  t  ( 1 - 3 0 ) : 5           S u c c e s s !
 - 51 -  3.4.2.5 Auto-On Setting   It allows an automatic input of fingerprint without pressing an Enter key by simply placing a finger on fingerprint sensor.      A u t o - O n   C h e c k    1   2   3   4   5    6    7    Please press ENTER to go into a sub menu.    A u t o - O n   C h e c k    O  N / O F F            S u c c e s s !                       The default value is 『ON』.
 - 52 -  3.4.2.6 1:N Time Setting  It limits the time for 1:N match, especially when the 1:N match time becomes too long due to many users. As most authentications take place at the beginning of 1:N match, it is unlikely to find an appropriate fingerprint after some time has passed since the search is  initiated. As  such, the  function is designed to eliminate  any  inconvenience  users  may  suffer  due  to  long waiting. If the function is not enabled, 1:N search is conducted for all DB within a terminal.     1  :  N    T  i  m  e  o  u  t         1   2   3   4   5   6    7    The following shows sub menus. Please determine if you wish to use the function or not.      U  s  e    T  i  m  e  o  u  t        1  2                U  s  e    T  i  m  e  o  u  t        O  N / O F F             S u c c e s s !                       When selecting On to activate the function, you have to set the limit for Timeout. The default value is 『3 seconds』.
 - 53 -    S  e  t    T  i  m  e  o  u  t        1  2             Please select appropriate timeout limit.    S  e  t    T  i  m  e  O  u  t        ( 2 - 9 ) : 2            S u c c e s s !                        3.4.2.7 Free Scan Mode (1:1 match only mode)  It forbide 1:N match and SID match in terminal if the option is set in ON. The default value is 『OFF』    F r e e S c a n   M od  e   1  2  3  4  5  6  7     F  r  e  e  S  c  a  n    M  o  d e       O N / O  F  F
 - 54 -   3.4.3 UI (User Interface) Setting  The third function under the main menu is UI setting.   3.4.3.1 Language    You can select the type of language for LCD display.   In case of language Type A, you can select Korean, English, Japanese, Chinese, Spanish French, Thai and Indonesian. In case of language Type B, you can select Korean, English, Polish,  Farsi,  Malay,  Hebrew,  Vietnamese(voice  only),  and   Portuguese.      U I  O p t i o n     1  2  3    4    5    6    7      L a n g u a g e         1    2    3    4             E n g l i s h     1    2    4    4    5    6    7    8     S u c c e s s !
 - 55 -  3.4.3.2 Voice Guidelines                    V o i c e           1  2  3  4      V o i c e             O  N / O F F           S u c c e s s !
 - 56 -  3.4.3.3 Button tone     It decides whether you will hear a button tone or not when a specific button is pressed.        3.4.3.4 Function Key Display   It can select the message when you press the function key(F1~F4)        B e e p            1  2  3    4          B e e p              O  N / O F F           S u c c e s s !                             F u n c K e y   D i s p      1  2  3  4     F  u  n  c  K  e  y    D  i  s  p       O  F  F  /  M  O  D  E  1  /  M  O  D  E  2
 - 57 -  The default value is 『OFF』 When the option is set in mode1 or mode2, Extended attendance mode is not supportted in NAC2500.  The following table shows the message depending on the option of fucntion key display.  Option  F1 KEY  F2 KEY  F3 KEY  F4 KEY Off  F1  F2  F3  F4 Mode1  Clock In  Clock Out Absense  Return Mode2  Check In Check Out F3  F4   3.4.4 System Setting  The fourth main menu is system setting.    You can then enter into the sub menu of System Option.  3.4.4.1 Log Storage  The first menu decides whether to store log or not.      S u c c e s s !                           S  y  s  t  e  m    O  p  t  i  o  n     1   2   3   4    5    6    7     S  y  s  t  e  m    O  p  t  i  o  n   1    2    3    4    5    6    7    8
 - 58 -  When  log  is  on,  relevant  authentication  log  during  user authentication is sent to a server.           L O G        1    2    3    4    5    6    7    8  L O G              O  N / O F F
 - 59 -  3.4.4.2 RF CARD  It is to select whether RF CARD is used for user authentication. Please use a directional button and press ENTER to finish.    You have three options: OFF RF CARD is not used, 26bit for low frequency HID card, 34bit for high frequency Mifare card.          R F  c a r d     1    2    3    4    5    6    7    8 R F  c a r d         O  F  F  /  2  6  b  i  t  /  3  4  b  i  t     S u c c e s s !
 - 60 -  3.4.4.3 Wiegand  It decides whether to use Wiegand communication protocol to send authentication results and user ID to a server.   Please press ENTER to go into a sub menu.  Please  decide  whether  to  use  Wiegnad  protocol  or  not.  When choosing OFF, item number 2 and 3 will disappear from Wiegand menu.      When you choose to use Wiegand, you have to select Facility code for the relevant bit display. If RF is set at 26 bits in the previous menu, Wiegand should be set at 26 bits. 34 bits RF should be matched against 34 bits wiegand.  Facility code for 26 bits has values between 1~255.     W I E G A N D     1    2    3    4    5    6    7    8   U  s  e    W  i  e  g  a  n  d    ?       1  2  3         U  s  e    W  i  e  g  a  n  d    ?     O N / O  F  F             2 6 b i T           1  2  3
 - 61 -   Please set the facility code for 34 bits.     % please refer to the appendix for details about Wiegand output format.  F  a  c  i  l  i  t  y    C  o  d  e     ( 1 - 2 5 5 ) :            3 4 b i t           1  2  3       F  a  c  i  l  i  t  y    C  o  d  e     (  1  -  3  2  7  6  7  )  :
 - 62 -  3.4.4.4 Function Key  It decides whether to use Function keys (F1~F4) or not. When access control mode is set, function keys will not be used. Yet, attendance mode will use function keys. In case of Function key mode, you have to decide to use Auto T&A and Expanded T&A.   AC refers to access control mode and T&A refers to attendance mode.   If you decide to use T&A mdoe, following the message is also displayed to decide Auto T&A mode. The default value is 『NO』   When you select to use T&A mdoe, following the message is also displayed to decide expanded T&A mode. The default value is 『NO』     F u n c t i o n   M o d e  1    2    3    4    5    6    7    8   F u n c t i o n   M o d e     A C / T  &  A       A  u  t  o    T  &  A    M  o  d  e         Y E S / N  O        E  x  p  a  n  d  e  d    T  &  A           Y E S / N  O
 - 63 -  3.4.4.5 Authentication Mode  Please select authentication mode.    There are 2 modes available. In SO mode, a terminal is not connected to network and operates standalone. In this case, database  only  within  the  terminal  is  searched  for authentication. In NL mode, a terminal is connected to network and  it  requires a  server  authentication.  Please  refer  to Access manager manual for details on server authentication.     3.4.4.6 Time Setting  You can set time for a terminal.   The setting is sustained for 9 hours during power shortage.      A u T h  M o d e    1    2    3    4    5    6    7    8 A u t h  M o d e         S  O / N L             T  i  m  e    S  e  t  t  i  n  g   1    2    3    4    5    6    7    8 2  0  0  6  /  0  3  /  0  1           1 1 : 4 6 : 1 9
 - 64 -  3.4.4.7 Terminal Mode  Terminal mode is an option to control Wiegand output. When a terminal is set at normal mode, wiegand output is Facility Code and user ID. If it is set at reader mode, wiegand output is ay values read from a card reader.       T e r m i n a l   M o d e  1    2    3    4    5    6    7    8   T e r m i n a l   M o d e   R  e  a  d  e  r  /  A  c  c  e  s  s
 - 65 -  3.4.4.8 Time zone  It is to decide whether to use Time zone or not. It Time zone is on, the function will be used. Please refer to Access manager manual for details on the use of time zone.        T i m e z o n e   M o d e  1    2    3    4    5    6    7    8   T i m e z o n e   M o d e   O  N / O F F
 - 66 -   3.4.5  Network Setting  The fifth main menu is network setting.   When selecting network setting, you will find the following 4 sub menu.    3.4.5.1Terminal ID  The values for Terminal ID should not be overlapping within one server and a unique number for each terminal is used for network access.   The values can vary between 1~255.         N e t w o r k       1   2   3   4   5    6    7      [ N e t w o r k ]       1  2  3  4          T e r m i n a l   I D       1  2  3  4      T  e  r  m  i  n  a  l    I  D         (  1  -  2  5  5  )  :  2  5  5
 - 67 -  3.4.5.2 TCP/IP  The following is about TCP/IP setting.    There are 5 sub-menus out of which 2 may not appear depending on DHCP setting.   ① DHCP          T C P / I P          1  2  3  4         U s e  D H C P ?       1    2    3    4    5       U s e  D H C P ?        O  N / O F F
 - 68 -  ② Terminal IP  Terminal IP is manually set. It does not appear if DHCP is ON.      ③ Subnet Mask  Subnet mask is manually set. It does not appear if DHCP is ON.        T e r m i n a l   I P       1  2  3  4  5    T  e  r  m  i  n  a  l    I  P           0  .      0  .      0  .      0     s u b n e t   m a s k       1  2  3    4    5       s  u  b  n  e  T    m  a  s  k         2  5  5  .  2  5  5  .      0  .      0
 - 69 -  ④ Gateway  Gateway can be  set when needed and it is used mostly when connected to external network. If the system is used only within Intranet, you do not need to input any value for it.      ⑤ Server IP  Please input Server IP that has an Access Server installed and the value of the IP should be a fixed IP.          G a t e w a Y        1  2  3  4  5    G a t e w a y           0  .      0  .      0  .      0    S e r v e r  I P       1  2  3  4  5       S e r v e r  I P         0  .      0  .      0  .      0
 - 70 -  3.4.5.3 Limiting Communication Time  A terminal sends a signal on a regular basis in order to check connection status to a server, and the current menu selects the cycle. The value should be set with an extreme caution and both long and short time have strength and weakness.   When the time is short, the terminal status is quickly reflected to a server. In turn, longer time makes a response slower. If the  value is too  small, network connection is on  and off continuously  if  communication  lines  are  not  in  a  good condition.  Therefore, this value should be changed depending on network environment and mostly, it is desirable to use factory setting values.          N  /  W    T  i  m  e  o  u  T        1  2  3  4      N / W   T I m e o u T        (  2  -  2  0  )  :      3
 - 71 -  3.4.5.4 Port Setting  Please input connection port number to be used for a server. In most cases, factor setting values do not change.          P  o  r  t    N  u  m  b  e  r        1  2  3  4      P o r t   N u m b e r        :  7 3 3 2
 - 72 -  3.4.6    Cofirmation of Terminal Information   You can check terminal information from the sixth main menu.   3.4.6.1 Number of Users   It  gives  information  on  the  number  of  users  currently registered in a terminal. There are normal users and master users.     Currently, the system has 123 normal users and 4 master users.       I n f o r m a t i o n      1   2   3   4   5   6    7      #  O f  U s e r          1  2         N O R M A L :   1 2 3        M A S T E R :       4
 - 73 -  3.4.6.2 Version Check  You can find information on the version of firmware in a terminal.    The current firmware version is 2.500-00.      F  /  W    V  e  r  s  i  o  n           1  2       F / W   V e r s i o n            2 . 5 0 0 - 0 0
 - 74 -   3.4.7 Factory Default Setting  The  menu is used  only once during factory testing or site installation.     3.4.7.1 DB Format    All DB are formatted.      When format is completed, the system goes back to the initial screen.      F a c t o r y   I n i t    1   2   3   4   5   6   7      D B  F o r m a t       1    2    3    4    5          D B  F o r m a t    Y  E  S / N O          A  r  e    Y  o  u    S  u  r  e  ?     Y  E  S / N O              F o r m a t i n g . .
 - 75 - 3.4.7.2 Factory Format  Factory Format is a command to restore all information stored within a terminal into initial values including user DB, option DB, log information and logo. Therefore, the function should be used with an extreme caution.        F  a  c  t  o  r  y    F  o  r  m  a  t      1  2  3  4  5    F  a  c  t  o  r  y    F  o  r  m  a  t   Y  E  S / N O          A  r  e    Y  o  u    S  u  r  e  ?     Y  E  S / N O              F o r m a t i n g . .
 - 76 -  3.4.7.3 Number of Registered Fingerprint  It determines the number of fingerprint that can be registered per one user between 1 and 2. (Will expand to 5 in future) However, the value cannot be change if there is DB.      3.4.7.4 Number of Characters in ID  The length of ID for a site will be selected. As the length of ID is a fixed value for each site, the function should be used with an extreme caution. The value cannot be changed if there is DB in existence.        F P  N u m b e r       1  2  3    4    5       F P  N u m b e r       1  /  2                I D  L e n g t h       1  2  3  4  5    I D  L e n g t h       ( 4 - 1 5 ) :  4
 - 77 -  3.4.7.5   Reset Terminal    Terminals can be reset without disassembling. Please choose 『yes』 in a confirmation screen to reset a terminal.        R e s e t  T e r m      1  2  3  4  5       A  r  e    Y  o  u    S  u  r  e  ?     Y  E  S / N O
 - 78 - Appendix  1:  Network  Connection  Error  and Solutions   When a terminal is not registered in a server, it should be registered on the server.        When a terminal ID is not valid, please check the ID again and set it again with a valid ID (1~255.)      If the number of user ID characters in a server and a terminal is not the same, please set the same number of characters for both IDs.        If the number of registered user fingerprints in a server and a terminal is not the same, please set the same number of fingerprints for the server and the terminal. 0 0 1        U  N  R  E  G  I  S  T  E  R 0 0 2        T  E  R    I  D    E  R  R 0 0 3        I  D    #       E  R  R
 - 79 -     When a terminal ID conflicts, please change the terminal ID into an unregistered one.       When MAC Address is not consistent, please contact the customer service center.      0 0 4        #  F  P         E  R  R   0 0 5        T  E  R  I  D  C  O  N  F  LICT0 0 6         M  A  C    A  D  D  R  ERR
 - 80 - Appendix 2: Terminal Initialization Error and Solutions  The following is a list of terminal initialization errors and solutions.   Err. Code  Details  Solution 001 Unidentified Error  Rebooting or A/S 002 FPGA  Initialization Failure  Rebooting or A/S 003  LCD  Initialization Failure To check LCD module connection or A/S 004  RTC  Initialization Failure  A/S 005  Optic module Error  To check Optic module connection or A/S 010 System Software Error A/S 011  A/S 012  A/S 013  A/S 014  A/S 015  Rebooting 016  A/S  ※ Error code 001~003 refer to steps before LCD initialization and therefore do not appear on LCD screen.
 - 81 - Appendix 3: Law and Regulation   Device Type  User Guideline B-level Device (home communication device) The device is designed for home users and  can  be  used  for  all  locations including residential areas as it is registered  as  a  qualified  device against electromagnetic wave.
 - 82 - Appendix 4: Wiegand Protocol Format  1. Wiegand Input  - 26 Bit   P  8 Bit (site code)  16 Bit (card number)  P LSB                                               MSB  - 34 Bit P  16 Bit (site code)  16 Bit (card number)  P LSB                                               MSB
 - 83 -  2. Wiegand Output   Output: MSB → LSB  Even Parity: Odd number 1  Odd Parity: Even number 1    Terminal mode <Access Controller> - 26 Bit   P  8 Bit (facility code)  16 Bit (user ID)  P Even Parity                                  Odd Parity LSB                                               MSB   - 34 Bit P  16 Bit (facility code)  16 Bit (user ID)  P Even Parity                                  Odd Parity LSB                                               MSB   Terminal mode <Reader>  Wiegand Input to be used without any change.
 - 84 - Appendix 5 : EMERGENCY Screen  1) EMERGENCY (Door Open) When a door is forced open by an unauthorized user for access, doors with door sensors detect the attempt and display the following EMERGENCY message.      In this case, the emergency will be cancelled when the door is checked by a system manager who enters into the menu in a terminal. Please check the following if the emergency message continuously appears.  Door sensor Y or N Check Yes  - operation of door sensor - connection status of door sensor No  If warning time for “door open” is set at 0 (see 2.4 Door Setting)   E  M  E  R  G  E  N  C  Y  !           D  o  o  r    O  p  e  n  !