Nec P403 Users Manual

2015-05-18

: Nec Nec-P403-Users-Manual-726543 nec-p403-users-manual-726543 nec pdf

Open the PDF directly: View PDF PDF.
Page Count: 141

DownloadNec Nec-P403-Users-Manual-  Nec-p403-users-manual
Open PDF In BrowserView PDF
External Control

NEC LCD Monitor
Rev.2.0 (G2)

INDEX

I. Application ................................................................................ 4
II. Preparation ............................................................................... 5
2. Connectors and wiring .................................................................... 5
2.1 RS-232C Remote control ............................................................... 5
2.2 LAN control ........................................................................... 5
III. Communication specification ............................................................... 7
3. Communication Parameter ................................................................ 7
3.1 RS-232C Remote control ............................................................... 7
3.2 LAN control ........................................................................... 7
3.3 Communication timing ................................................................. 7
4. Communication Format ................................................................... 8
4.1 Header block format (fixed length) ...................................................... 9
4.2 Message block format ................................................................ 11
4.3 Check code .......................................................................... 13
4.4 Delimiter ............................................................................ 14
5. Message type ........................................................................... 15
5.1 Get current Parameter from a monitor. ................................................. 15
5.2 "Get parameter" reply ................................................................. 16
5.3 Set parameter ........................................................................ 18
5.4 "Set parameter" reply ................................................................. 19
5.5 Commands ........................................................................... 20
5.5.1 Save Current Settings . ............................................................ 20
5.5.2 Get Timing Report and Timing reply. ................................................ 21
5.5.3 NULL Message .................................................................... 22
IV. Control Commands ....................................................................... 23
6. Typical procedure example ............................................................... 23
6.1. How to change the “Backlight” setting. ................................................ 23
6.2. How to read the measurement value of the built-in temperature sensors. .................. 26
6.3. Operation Code (OP code) Table ....................................................... 29
7. Power control procedure ................................................................. 44
7.1 Power status read .................................................................... 44
7.2 Power control ........................................................................ 46
8. Asset Data read and write ................................................................ 48
8.1 Asset Data Read Request and reply .................................................... 48

(1/141)

8.2 Asset Data write ..................................................................... 50
9. Date & Time read and write .............................................................. 52
9.1 Date & Time Read .................................................................... 52
9.2 Date & Time Write .................................................................... 54
10. Schedule read and write ................................................................ 57
10.1 Schedule Read ...................................................................... 57
10.2 Schedule Write ...................................................................... 62
11. Self diagnosis .......................................................................... 72
11.1 Self-diagnosis status read ............................................................ 72
12. Serial No. & Model Name Read .......................................................... 74
12.1 Serial No. Read ...................................................................... 74
12.2 Model Name Read ................................................................... 76
13. Security Lock .......................................................................... 78
13.1 Security Lock Control ................................................................ 78
14. Direct TV Chanel Read & Write .......................................................... 80
14.1 Direct TV Chanel Read & Reply ....................................................... 80
14.2 Direct TV Chanel Write & Reply ....................................................... 81
15. Daylight Saving read & write ............................................................ 82
15.1 Daylight Saving Read ................................................................ 82
15.2 Daylight Saving Write ................................................................ 84
16. Firmware Version ...................................................................... 86
16.1 Firmware Version Read .............................................................. 86
17. Auto ID ................................................................................ 88
17.1 Auto ID Execute ..................................................................... 88
17.2 Auto ID Complete .................................................................... 90
17.3 Auto ID Reset ....................................................................... 92
18. Input Name ............................................................................ 93
18.1 Input Name Read .................................................................... 93
18.2 Input Name Write .................................................................... 95
18.3 Input Name Reset ................................................................... 97
19. Auto Tile Matrix ........................................................................ 99
19.1 Auto Tile Matrix Execute ............................................................. 99
19.2 Auto Tile Matrix Complete ........................................................... 101
19.3 Auto Tile Matrix Monitors Read ...................................................... 103
19.4 Auto Tile Matrix Monitors Write ...................................................... 105
19.5 Auto Tile Matrix Reset .............................................................. 107
20. Power Save Mode ..................................................................... 109
20.1 Power Save Mode Read ............................................................. 109

(2/141)

20.2 Power Save Mode Write ............................................................. 111
20.3 Auto Power Save Time Read ......................................................... 113
20.4 Auto Power Save Time Write ........................................................ 114
20.5 Auto Standby Time Read ............................................................ 116
20.6 Auto Standby Time Write ............................................................ 117
21. Setting Copy .......................................................................... 119
21.1 Setting Copy Read .................................................................. 119
21.2 Setting Copy Write .................................................................. 121
21.3 Setting Copy Start .................................................................. 123
22. Security Enable ....................................................................... 125
22.1 Security Enable Read ............................................................... 125
22.2 Security Enable Write ............................................................... 127
23. LAN MAC Address ..................................................................... 129
23.1 LAN MAC Address Read ............................................................. 129
24. Proof of Play .......................................................................... 131
24.1 Start Proof of Play .................................................................. 131
24.2 Stop Proof of Play .................................................................. 133
24.3 Get Proof of Play Current ............................................................ 135
24.4 Get Proof of Play Total Number ...................................................... 137
24.5 Get Proof of Play Number to Number ................................................. 139

(3/141)

I. Application
This document defines the communications method for control of the NEC LCD monitor, MultiSync P403/
P463 /P553 /P703 /P801 /X464UN /X554UN /X464UNV /X554UNS when using an external controller.

(4/141)

II. Preparation
2. Connectors and wiring
2.1 RS-232C Remote control

Connector: 9-pin D-Sub
Cable: Cross (reversed) cable or null modem cable

(Please refer “Controlling the LCD monitor via RS-232C Remote control” on User’s manual.)

2.2 LAN control
Connector: RJ-45 10/100 BASE-T
Cable: Category 5 or higher LAN cable

(5/141)

(Please refer “Controlling the LCD monitor via LAN control” on User’s manual.)

(6/141)

III. Communication specification
3. Communication Parameter
3.1 RS-232C Remote control
(1)
(2)
(3)
(4)
(5)
(6)
(7)

Communication system
Interface
Baud rate
Data length
Parity
Stop bit
Communication code

Asynchronous
RS-232C
9600bps
8bits
None
1 bit
ASCII

3.2 LAN control
(1) Communication system
(2) Interface
(3) Communication layer
(4) IP address
(5) Port No.

TCP/IP (Internet protocol suite)
Ethernet (CSMA/CD)
Transport layer (TCP)
* Using the payload of TCP segment.
(Default) Automatic setup
* If you need to change,
Please refer “Network settings” on User’s manual.
7142 (Fixed)

(Note)
The monitor will disconnect the connection if no packet data is received for 15 minutes.
And the controller (PC) has to re-connect to control the monitor again, after 15 minutes or more.

3.3 Communication timing
The controller should wait for a reply packet before next command is sent.
(Note)
A normal answer cannot be performed when a monitor is a busy state.
Please refer “5.5.3 NULL message”.

(7/141)

4. Communication Format
Header

Message

Check Code

Delimiter

The command packet consists of four parts, Header, Message, Check code and Delimiter.
Recommended sequence of a typical procedure to control a monitor is as follows,
[A controller and a monitor, two-way communication composition figure]
■ For the general command (see the part "6.3. Operation Code (OP code) Table”)

Controller

Monitor
Get Parameter
Header

Message

Check Code

Delimiter

The controller sends command to
get a value from the monitor that
you want to change.

Delimiter

The monitor replies a current value
of the requested item.

Delimiter

The controller sends commands to
set an adjusted value.

Delimiter

The monitor replies to the
controller for confirmation.

Get Parameter Reply
Header

Message

Check Code

Set Parameter
Header

Message

Check Code

Set Parameter Reply
Header

Message

Check Code

Get Parameter
Header

Message

Check Code

Delimiter

The controller sends command to
get a value for confirmation.

Delimiter

The monitor replies an adjusted
value.

Get Parameter Reply
Header

Message

Check Code

Save Current Setting Command
Header

Message

Check Code

Delimiter

Save Current Setting Command Reply
Header

Message

Check Code

Delimiter

The controller requests to store
the adjusted value to the monitor.
The monitor replies to the
controller for confirmation.

■ For the special command (see the part 7 to 24. and 5.5.2)

Controller

Monitor
Command
Header

Message

Check Code

Delimiter

Command Reply
Header

Message

Check Code

Delimiter

(8/141)

The control does not suitable for
above fixed protocol; use the
proper command for each control.
Please refer section 5.5 and
section 7 to 24.
The monitor replies a proper
message defined for each control.

Header

4.1 Header block format (fixed length)
SOH
1st

Reserved
'0'
2nd

Destination
3rd

Source

Message

Message
Type

4th

5th

Check code

Delimiter

Message
Length
6th -7th

1stbyte) SOH: Start of Header
ASCII SOH (01h)
2ndbyte) Reserved: Reserved for future extensions.
On this monitor, it must be ASCII '0'(30h).

3rdbyte) Destination: Destination equipment ID. (Receiver)
Specify a commands receiver’s address.
The controller sets the “MONITOR ID” or “GROUP ID” of the monitor controlled in here.
On the reply, the monitor sets ‘0’ (30h), always.

“MONITOR ID”, “GROUP ID” to “Destination Address” conversion table is as follows,
Monitor
ID
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
ALL

Destination
Address
41h(‘A’)
42h(‘B’)
43h(‘C’)
44h(‘D’)
45h(‘E’)
46h(‘F’)
47h(‘G’)
48h(‘H’)
49h(‘I’)
4Ah(‘J’)
4Bh(‘K’)
4Ch(‘L’)
4Dh(‘M’)
4Eh(‘N’)
4Fh(‘O’)
50h(‘P’)
51h(‘Q’)
52h(‘R’)
53h(‘S’)
54h(‘T’)
55h(‘U’)
56h(‘V’)
57h(‘W’)
58h(‘X’)
59h(‘Y’)
2Ah(‘*’)

Monitor
ID
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50

Destination
Address
5Ah(‘Z’)
5Bh
5Ch
5Dh
5Eh
5Fh
60h
61h
62h
63h
64h
65h
66h
67h
68h
69h
6Ah
6Bh
6Ch
6Dh
6Eh
6Fh
70h
71h
72h

Monitor
ID
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75

Destination
Address
73h
74h
75h
76h
77h
78h
79h
7Ah
7Bh
7Ch
7Dh
7Eh
7Fh
80h
81h
82h
83h
84h
85h
86h
87h
88h
89h
8Ah
8Bh

Monitor
ID
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100

Destination
Address
8Ch
8Dh
8Eh
8Fh
90h
91h
92h
93h
94h
95h
96h
97h
98h
99h
9Ah
9Bh
9Ch
9Dh
9Eh
9Fh
A0h
A1h
A2h
A3h
A4h

Group
ID
A
B
C

Destination
Address
31h(‘1’)
32h(‘2’)
33h(‘3’)

Group
ID
D
E
F

Destination
Address
34h(‘4’)
35h(‘5’)
36h(‘6’)

Group
ID
G
H
I

Destination
Address
37h(‘7’)
38h(‘8’)
39h(‘9’)

Group
ID
J

Destination
Address
3Ah(‘:’)

(9/141)

Ex.) If you want to control a monitor that has the "ID No." as '1', specify a destination address
'A'(41h). If you want to control all of the monitors which are connected by a daisy chain, specify
a destination address ‘*’(2Ah).

4thbyte) Source: Source equipment ID. (Sender)
Specify a sender address.
The controller must be ‘0’ (30h).
On the reply, the monitor sets the own MONITOR ID in here.

5thbyte) Message Type: (Case sensitive.)
Refer to section 4.2 “Message block format” for more details.
ASCII 'A' (41h): Command.
ASCII 'B' (42h): Command reply.
ASCII 'C' (43h): Get current parameter from a monitor.
ASCII 'D' (44h): "Get parameter" reply.
ASCII 'E' (45h): Set parameter.
ASCII 'F' (46h): "Set parameter" reply.

6th -7th bytes) Message Length:
Specify the length of the message (that follows the header) from STX to ETX.
This length includes STX and ETX.
The byte data must be encoded to ASCII characters.
Ex.) The byte data 3Ah must be encoded to ASCII characters '3' and 'A' (33h and 41h).
The byte data 0Bh must be encoded to ASCII characters '0' and 'B' (30h and 42h).

(10/141)

4.2 Message block format

Message

Header

Check code

Delimiter

“Message block format” is allied to the “Message Type” in the “Header”.
Refer to the section 4.1 “Header block format” for more detail.
1)Get current parameter
The controller sends this message when you want to get the status of the monitor.
For the status that you want to get, specify the “OP code page” and “OP code”,
refer to “Appendix A. Operation code table”.
“Message format” of the “Get current parameter” is as follows,
STX

Ø

OP code
page
Hi
Lo

ETX

OP code
Hi

Lo

Refer to section 5.1 “Get current parameter from a monitor.” for more details.

2)Get Parameter reply
The monitor will reply with the status of the requested item specified by the controller
in the “Get parameter message”.
“Message format” of the “Get parameter reply” is as follows,
STX

Result
Hi

Lo

Ø

OP code
page
Hi
Lo

Type

OP code
Hi

Lo

Hi

Max value

Lo

MSB

Current Value
LSB

MSB

ETX

LSB

Refer to section 5.2 “Get parameter reply” for more details.

3)Set parameter
The controller sends this message to change a setting of the monitor.
Message format of the “Set parameter” is as follows,
STX

Ø

OP code
page
Hi
Lo

Set Value

OP code
Hi

Lo

MSB

ETX
LSB

Refer to section 5.3 “Set parameter” for more details.

4)Set Parameter reply
The monitor replies with this message for a confirmation of the “Set parameter message”.
Message format of the “Set parameter reply” is as follows,
STX

Result
Hi

Ø

Lo

OP code
page
Hi
Lo

OP code
Hi

Lo

Type
Hi

Max value

Lo

MSB

LSB

Requested setting
Value
MSB
LSB

ETX

Refer to section 5.4 “Set parameter reply” for more details.

5)Command
“Command message” format depends on each command.
Usually, this “command message” is used for some non-slider controls and some special operations,

(11/141)

such as “Save current settings”, “Get timing report”, “power control”, “Schedule”, etc. Refer to
section 5.5 “Commands message” for more details.

6)Command reply
The monitor replies to a query from the controller.
“Command reply message” format depends on each command.
Refer to section 5.5 “Commands message” for more details.

(12/141)

Header

4.3 Check code

Message

Check code

Delimiter

Check code is the Block Check Code (BCC) between the Header and the End of Message except SOH.

SOH
Reserved
Destination
Source
Type
Length(H)
Length(L)
STX
Data
|
|
ETX
Check code

D0
D1
D2
D3
D4
D5
D6
D7
D8
|
|
Dn
Dn+1

27

26

25

24

23

22

21

20

P

P

P

P

P

P

P

P

Dn+1 = D1 XOR D2 XOR D3 XOR ,,, Dn
XOR: Exclusive OR

Following is an example of a Check code (BCC) calculation.

Header
SOH Reserved

Message

Destination
Address

Source
Address

Message
type

Message length

STX

OP code
page

OP code

Set Value

Delimiter

ETX

Check
code
(BCC)

01

30

41

30

45

30

41

02

30 30 31 30 30 30 36 34

03

77

0D

D0

D1

D2

D3

D4

D5

D6

D7

D8

D16

D17

D18

D9 D10 D11 D12 D13 D14 D15

Check code (BCC) D 17 = D 1 xor D 2 xor D 3 xor … xor D14 xor D15 xor D 16
= 30h xor 41h xor 30h xor 45h xor 30h xor 41h
xor 02h xor 30h xor 30h xor 31h xor 30h xor 30h
xor 30h xor 36h xor 34h xor 03h
= 77h

(13/141)

4.4 Delimiter

Header

Message

Check code

Packet delimiter code; ASCII CR(0Dh).

(14/141)

Delimiter

5. Message type
5.1 Get current Parameter from a monitor.
STX
1st

OP code
page
Hi
Lo
2nd-3rd

OP code
Hi

Lo
4th–5th

ETX
6th

Send this message when you want to get the status of a monitor.
For the status that you want to get, specify the “OP code page” the “OP code”, refer to “Appendix
A. Operation code table”.

1stbyte) STX: Start of Message
ASCII STX (02h)
2nd-3rdbytes) OP code page: Operation code page.
Specify the “OP code page” for the control which you want to get the status.
Refer to “Appendix A Operation code table” for each item.
OP code page data must be encoded to ASCII characters.
Ex.) The byte data 02h must be encoded to ASCII characters '0' and '2' (30h and 32h).
OP code page 02h ->

OP code page (Hi) = ASCII '0' (30h)
OP code page (Lo) = ASCII '2' (32h)

Refer to Operation code table. (Appendix A)
th

4 –5thbytes) OP code: Operation code
Refer to “Appendix A Operation code table” for each item.
OP code data must be encoded to ASCII characters.
Ex.) The byte data 3Ah must be encoded to ASCII characters '3' and 'A' (33h and 41h).
OP code 3Ah ->

OP code (Hi) = ASCII '3' (33h)
OP code (Lo) = ASCII 'A' (41h)

Refer to Operation code table.
th

6 byte) ETX: End of Message
ASCII ETX (03h)

(15/141)

5.2 "Get parameter" reply
STX

Result

1st

Hi
Lo
2nd-3rd

OP code
page
Hi
Lo
4th–5th

OP code

Type

Hi
Lo
6th –7th

Hi
Lo
8th -9th

Max value
MSB

10th -13 th

LSB

Current Value
MSB

14th -17 th

LSB

ETX
18th

The monitor replies with a current value and the status of the requested item (operation code).
1stbyte) STX: Start of Message
ASCII STX (02h)
2nd-3rdbytes) Result code.
These bytes indicate a result of the requested commands as follows,
00h: No Error.
01h: Unsupported operation with this monitor or unsupported operation under current condition.
This result code from the monitor is encoded to ASCII characters.
Ex.) The byte data 01h is encoded to ASCII character '0' and '1' (30h and 31h).
th

4 –5thbytes) OP code page: Operation code page.
These bytes indicate a replying item's OP code page.
This returned value from the monitor is encoded to ASCII characters.
Ex.) The byte data 02h is encoded to ASCII character '0' and '2' (30h and 32h).
Refer to the operation code table.
6th –7thbytes) OP code: Operation code
These bytes indicate a replying item's OP code.
This returned value from the monitor is encoded to ASCII characters.
Refer to the operation code table.
Ex.) The byte data 1Ah is encoded to ASCII character '1' and 'A' (31h and 41h).
8th -9thbytes) Type: Operation type code
00h: Set parameter
01h: Momentary
Like the Auto Setup function which automatically changes the parameter.
This returned value from the monitor is encoded to ASCII characters.
Ex.) The byte data 01h is encoded to ASCII character '0' and '1' (30h and 31h).
th

10 -13 thbytes) Max. value: Maximum value which monitor can accept. (16bits)
This returned value from the monitor is encoded to ASCII characters.
Ex.) '0','1','2' and '3' means 0123h (291)
14th -17 th bytes) Current Value: (16bits)
This returned value from the monitor is encoded to ASCII characters.
Ex.) '0','1','2' and '3' means 0123h (291)

(16/141)

18th byte) ETX: End of Message
ASCII ETX (03h)

(17/141)

5.3 Set parameter
STX
1st

OP code
page
Hi
Lo
2nd-3rd

OP code
Hi
Lo
4th-5th

Set Value
MSB

6th-9th

ETX
LSB

10th

Send this message to change monitor’s adjustment and so on.
The controller requests a monitor to change value.
1stbyte) STX: Start of Message
ASCII STX (02h)
2nd-3rdbytes) OP code page: Operation code page
This OP code page data must be encoded to ASCII characters.
Ex.) The byte data 02h must be encoded to ASCII '0' and '2' (30h and 32h).
Refer to the Operation code table.
th

4 -5thbytes) OP code: Operation code
This OP code data must be encoded to ASCII characters.
Ex.) OP code 1Ah ->

OP code (Hi) = ASCII '1' (31h)
OP code (Lo) = ASCII 'A' (41h)

Refer to the Operation code table.
6th-9thbytes) Set value: (16bit)
This data must be encoded to ASCII characters.
Ex.) 0123h ->

1st(MSB) = ASCII '0' (30h)
2nd = ASCII '1' (31h)
3rd = ASCII '2' (32h)
4th(LSB) = ASCII '3' (33h)

10th byte) ETX: End of Message
ASCII ETX (03h)

(18/141)

5.4 "Set parameter" reply
STX

Result

1st

Hi
Lo
2nd-3rd

OP code
page
Hi
Lo
4th-5th

OP code

Type

Hi
Lo
6th-7th

Hi
Lo
8th-9th

Max value
MSB

10th -13 th

LSB

Requested setting
Value
MSB
LSB
14th -17 th

The Monitor echoes back the parameter and status of the requested operation code.
1stbyte) STX: Start of Message
ASCII STX (02h)
2nd-3rdbytes) Result code
ASCII '0''0' (30h, 30h): No Error.
ASCII '0''1' (30h, 31h): Unsupported operation with this monitor or unsupported operation under
current condition.
th

4 -5thbytes) OP code page: Echoes back the Operation code page for confirmation.
Reply data from the monitor is encoded to ASCII characters.
Ex.) OP code page 02h ->

OP code page = ASCII '0' and '2' (30h and 32h)

Refer to Operation code table.
6th-7thbytes) OP code: Echoes back the Operation code for confirmation.
Reply data from the monitor is encoded to ASCII characters.
Ex.) OP code 1Ah ->

OP code (Hi) = ASCII '1' (31h)
OP code (Lo) = ASCII 'A' (41h)

Refer to Operation code table
th

8 -9thbytes) Type: Operation type code
ASCII '0''0' (30h, 30h): Set parameter
ASCII '0''1' (30h, 31h): Momentary
Like Auto Setup function, that automatically changes the parameter.
10th -13 thbytes) Max. value: Maximum value that monitor can accept. (16bits)
Reply data from the monitor is encoded to ASCII characters.
Ex.) '0''1''2''3' means 0123h (291)
14

th

-17 th bytes) Requested setting Value: Echoes back the parameter for confirmation. (16bits)
Reply data from the monitor is encoded to ASCII characters.
Ex.) '0''1''2''3' means 0123h (291)

th

18 byte) ETX: End of Message
ASCII ETX (03h)

(19/141)

ETX
18th

5.5 Commands
"Command message format" depends on each command. Some commands are shown with usage. Refer to section
7 to 13.

5.5.1 Save Current Settings.
The controller requests for the monitor to store the adjusted value.
STX

Command code
'0'
'C'

ETX

Ø

Send "OC"(30h, 43h) as Save current settings command.

Ø

Complete "Save Current setting" command packet as follows;

ASCII: 01h-30h-41h-30h-41h-30h-34h-02h-30h-43h-03h-CHK-0Dh
SOH-'0'-'A'-'0'-'A'-'0'-'4'-STX-'0'-'C'-ETX-CHK- CR
The monitor replies the packet for confirmation as follows;
SOH-'0'-'0'-'A'-'B'-'0'-'6'-STX-'0'-'0'-'0'-'C'-ETX-CHK- CR

(20/141)

5.5.2 Get Timing Report and Timing reply.
The controller requests the monitor to report the displayed image timing.
Command code
'0'
'7'

STX

ETX

Ø

Send "07"(30h, 37h) as Get Timing Report command.

Ø

Complete "Get Timing Report" command packet as follows;

ASCII: 01h-30h-41h-30h-41h-30h-34h-02h-30h-37h-03h-CHK-0Dh
SOH-'0'-'A'-'0'-'A'-'0'-'4'-STX-'0'-'7'-ETX-CHK- CR
The monitor replies status as the following format;
STX

Ø

Command
'4'
'E'

SS
Hi

H Freq.
Lo

MSB

V Freq.
LSB

MSB

ETX
LSB

SS: Timing status byte
Bit
Bit
Bit
Bit

7 = 1: Sync Frequency is out of range.
6 = 1: Unstable count
5-2
Reserved (Don't care)
1
1:Positive Horizontal sync polarity.
0:Negative Horizontal sync polarity.
Bit 0
1:Positive Vertical sync polarity.
0:Negative Vertical sync polarity.

Ø

H Freq: Horizontal Frequency in unit 0.01kHz

Ø

V Freq: Vertical Frequency in unit 0.01Hz
Ex.) When H Freq is '1''2''A''9' (31h, 32h, 41h, 39h), it means 47.77kHz.

(21/141)

5.5.3 NULL Message
STX

Command code
'B'
'E'

ETX

The NULL message returned from the monitor is used in the following cases;

Ø

To tell the controller that the monitor does not have any answer to give to the host (not
ready or not expected)

Ø

Following operation s need 15 seconds for to execute, so the monitor will return this message
when another message is received during execution.

²
Ø

Power ON and Power OFF

Following operations need 10 seconds for to execute, so the monitor will return this message
when another message is received during execution.

²
Ø

Auto Setup, Input, PIP Input, Auto Setup and Factory reset.

A null message will be returned by the monitor if the “Start Proof of Play” command is sent
and the monitor has already started Proof of Play.

Ø

A null message will be returned by the monitor if the “Stop Proof of Play” command is sent
and the monitor has not started Proof of Play.

Ø

Complete "NULL Message" command packet as follows;
01h-30h-30h-41h-42h-30h-34h-02h-42h-45h-03h-CHK-0Dh
SOH-'0'-'0'-'A'-'B'-'0'-'4'-STX-'B'-'E'-ETX-CHK- CR

(22/141)

IV. Control Commands
6. Typical procedure example
The following is a sample of procedures to control the monitor, these are examples of "Get parameter",
"Set parameter" and "Save current settings".

6.1. How to change the “Backlight” setting.
Step 1. The controller requests the Monitor to reply with the current brightness setting and capability
to support this operation. (Get parameter)
Header
SOH-'0'-Monitor ID'0'-'C'-'0'-'6'

Message
STX-'0'-'0'-'1'-'0'-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID from which you want to get a value.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'C' (43h): Message type is "Get parameter command".
'0'-'6' (30h, 36h): Message length is 6 bytes.
Message
STX (02h): Start of Message
'0'-'0' (30h, 30h): Operation code page number is 0.
'1'-'0' (31h, 30h): Operation code is 10h (in the OP code page 0).
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
Step 2. The monitor replies with current Backlight setting and capability to support this operation.
Header
SOH-'0'-'0'-Monitor ID'D'-'1'-'2'

Message
STX-'0'-'0'-'0'-'0'-'1'-'0'-'0'-'0'
-'0'-'0'-'6'-'4'-'0'-'0'-'3'-'2'-ETX

Check code
BCC

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'D' (44h): Message Type is "Get parameter reply".
'1'-'2' (31h, 32h): Message length is 18 bytes.
Message
STX (02h): Start of Message
'0'-'0' (30h, 30h): Result code. No error.
'0'-'0' (30h, 30h): Operation code page number is 0.
'1'-'0' (31h, 30h): Operation code is 10h (in the page 0).
'0'-'0' (30h, 30h): This operation is "Set parameter" type.
'0'-'0'-'6'-'4' (30h, 30h, 36h, 34h): Backlight max value is 100(0064h).
'0'-'0'-'3'-'2' (30h, 30h, 33h, 32h): Current Backlight setting is 50(0032h) .
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
(23/141)

Delimiter
CR

Delimiter
CR (0Dh): End of packet

Step 3. The controller request the monitor to change the Backlight setting
Header
SOH-'0'-Monitor ID'0'-'E'-'0'-'A'

Message
STX-'0'-'0'-'1'-'0''0'-'0'-'5'-'0'-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'E' (45h): Message Type is "Set parameter command".
'0'-'A' (30h, 41h): Message length is 10 bytes.
Message
STX (02h): Start of Message
'0'-'0' (30h, 30h): Operation code page number is 0.
'1'-'0' (31h, 30h): Operation code is 10h (in the page 0).
'0'-'0'-'5'-'0' (30h, 30h, 35h, 30h): Set Backlight setting 80(0050h).
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
Step 4. The monitor replies with a message for confirmation.
Header
SOH-'0'-'0'- Monitor ID –
'F'-'1'-'2'

Message
STX-'0'-'0'-'0'-'0'-'1'-'0'—'0'-'0''0'-'0'-'6'-'4'-'0'-'0'-'5'-'0'-ETX

Check
code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'F' (46h): Message Type is "Set parameter reply".
'1'-'2' (31h, 32h): Message length is 18 bytes.
Message
STX (02h): Start of Message
'0'-'0' (30h, 30h): Result code. No error.
'0'-'0' (30h, 30h): Operation code page number is 0.
'1'-'0' (31h, 30h): Operation code is 10h (in the page 0).
'0'-'0' (30h, 30h): This operation is "Set parameter" type.
'0'-'0'-'6'-'4' (30h, 30h, 36h, 34h): Backlight max value is 100(0064h).
'0'-'0'-'5'-'0' (30h, 30h, 35h, 30h): Received a Backlight setting was 80(0050h) .
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(24/141)

Ø
Repeat Step 1 and Step 2, if you need to check the Backlight setting. (Recommended)
Step 5. Request the monitor to store the Backlight setting. (Save Current Settings Command)
Header
SOH-'0'-Monitor ID'0'-'A'-'0'-'4'

Message
STX-'0-'C'-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID which you want to store the setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'4' (30h, 34h): Message length is 4 bytes.
Message
STX (02h): Start of Message
'0'-'C' (30h, 43h): Command code is 0Ch as "Save current settings".
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(25/141)

6.2. How to read the measurement value of the built-in temperature sensors.
MultiSync P403/ P463 /P553 /P703 /P801 /X464UN /X554UN /X464UNV /X554UNS have three built-in
temperature sensors.
The controller can monitor inside temperatures by using those sensors with external control.

The following shows the procedure for reading the temperatures from the sensors.

Step 1. Select a temperature sensor which you want to read.
Header
SOH-'0'-Monitor ID'0'-'E'-'0'-'A'

Message
STX-'0'-'2'-'7'-'8''0'-'0'-'0'-'1'-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID which you want to get a value.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'E' (45h): Message Type is "Set parameter command".
'0'-'A' (30h, 41h): Message length is 10 bytes.
Message
STX (02h): Start of Message
'0'-'2' (30h, 32h): Operation code page number is 2.
'7'-'8' (37h, 38h): Operation code is 78h (on page 2).
'0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): Select the temperature sensor #1 (01h).
00h: No meaning
01h: Sensor #1
02h: Sensor #2
03h: Sensor #3
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
Step 2. The monitor replies for confirmation.
Header
SOH-'0'-'0'-Monitor ID'F'-'1'-'2'

Message
STX-'0'-'0'-'0'-'2'-'7'-'8'-'0'-'0''0'-'0'-'0'-'3'-'0'-'0'-'0'-'1'-ETX

Check code
BCC

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicates a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'F' (46h): Message Type is "Set parameter reply".
'1'-'2' (31h, 32h): Message length is 18 bytes.
Message
STX (02h): Start of Message
'0'-'0' (30h, 30h): Result code. No error.
'0'-'2' (30h, 32h): Operation code page number is 2.
(26/141)

Delimiter
CR

'7'-'8' (37h, 38h): Operation code is
'0'-'0' (30h, 30h): This operation is
'0'-'0'-'0'-'3' (30h, 30h, 30h, 33h):
'0'-'0'-'0'-'1' (30h, 30h, 30h, 31h):
ETX (03h): End of Message

78h (in the page 2).
"Set parameter" type.
Number of temperature sensors are 3 (0003h).
temperature sensor is #1.

Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
Step 3. The controller requests the monitor to send the temperature from the selected sensor.
Header
SOH-'0'-Monitor ID'0'-'C'-'0'-'6'

Message
STX-'0'-'2'-'7'-'9'-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID which you want to get a value.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'C' (43h): Message Type is "Get parameter".
'0'-'6' (30h, 36h): Message length is 6 bytes.
Message
STX (02h): Start of Message
'0'-'2' (30h, 32h): Operation code page number is 2.
'7'-'9' (37h, 39h): Operation code is 79h (in the page 2).
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
Step 4. The monitor replies a temperature of selected sensor.
Header
SOH-'0'-'0'-Monitor ID'D'-'1'-'2'

Message
STX-'0'-'0'-'0'-'2'-'7'-'9'-'0'-'0'
-'F'-'F'-'F'-'F'-'0'-'0'-'3'-'2'-ETX

Check code
BCC

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'D' (44h): Message Type is "Get parameter reply".
'1'-'2' (31h, 32h): Message length is 18 bytes.
Message
STX (02h): Start of Message
'0'-'0' (30h, 30h): Result code. No error.
'0'-'2' (30h, 32h): Operation code page number is 2.
'7'-'9' (37h, 39h): Operation code is 79h (in the page 2).
'0'-'0' (30h, 30h): This operation is "Set parameter" type.
'F'-'F'-'F'-'F' (46h, 46h, 46h, 46h): Maximum value.
'0'-'0'-'3'-'2' (30h, 30h, 33h, 32h): The temperature is 25 degrees Celsius.

(27/141)

Delimiter
CR

Readout value is 2's complement.
Temperature [Celsius]
+125.0
+ 25.0
+ 0.5
0
- 0.5
- 25.0
- 55.0

Readout value
Binary
0000 0000 1111
0000 0000 0011
0000 0000 0000
0000 0000 0000
1111 1111 1111
1111 1111 1100
1111 1111 1001

1010
0010
0001
0000
1111
1110
0010

Hexadecimal
00FAh
0032h
0001h
0000h
FFFFh
FFCEh
FF92h

ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(28/141)

6.3. Operation Code (OP code) Table

PICTU RE

Item

OP code

Parameter

Remarks

BACKLIGHT

OP
code
page
00h

10h

CONTRAST

00h

12h

SHARPNESS

00h

8Ch

BRIGHTNESS

00h

92h

HUE

00h

90h

COLOR

02h

1Fh

COLOR TEMPERATURE

00h

54h

100K/step

COLOR TEMPERATURE
(CUSTOM)
R GAIN

00h

14h

00h

16h

B GAIN

00h

18h

G GAIN

00h

1Ah

COLOR CONTROL

00h

GAMMA CORRECTION

02h

RED:
9Bh
YELLOW:
9Ch
GREEN:
9Dh
CYAN:
9Eh
BLUE:
9Fh
MAGENTA:
A0h
68h

0: dark
|
100(64h): bright
0: low
|
100(64h): high
0: dull
|
24(18h): sharp
0: dark
|
100(64h): bright
0: purplish
|
100(64h): greenish
0: pale
|
100(64h): deep
0:2600K
|
74(4Ah):10000K
9: 10000K
11(0Bh): CUSTOM
0: Dark
|
255(FFh): Bright
0: Dark
|
255(FFh): Bright
0: Dark
|
255(FFh): Bright
0:
|
100(64h):(center)
|
200(C8h):

MOVIE
SETTINGS

ADAPTIVE CONTRAST

02h

8Dh

NOISE REDUCTION

02h

26h

(29/141)

0: No mean
1: NATIVE
4: 2.2
8: 2.4
7: S GAMMA
5: DICOM SIM.
6: PROGRAMABLE1
13(0Bh): PROGRAMABLE2
14(0Ch): PROGRAMABLE3
0: No mean
1: Off
2: LOW
4: High
0: Off
|
7: High

Page02 OPcode20h
also works as
same.

Item

OP
code
page
02h

OP code

Parameter

23h

PICTURE MODE

02h

1Ah

RESET
(PICTURE)

02h

CBh

AUTO SETUP

00h

1Eh

AUTO ADJUST

10h

B7h

H POSITION

00h

20h

V POSITION

00h

30h

CLOCK

00h

0Eh

PHASE

00h

3Eh

H RESOLUTION

02h

50h

V RESOLUTION

02h

51h

0: No mean
1: Off
2: Auto
0: No mean
1: sRGB
3: HIGHBRIGHT
4: STANDARD
5: CINEMA
8: CUSTOM1
9: CUSTOM2
0: No mean
2: Reset
Picture category
0: No mean
1: Execute
0: No mean
1: OFF
2: ON
0: Left side
|
Max.: Right side
0: Bottom side
|
Max.: Top side
0:
|
Max. :
0:
|
Max. :
0: Low
|
Max. : High
0: Low
|
Max.: High

ADJUS T

TELECINE

(30/141)

Remarks

sRGB:
PC mode only
CINEMA:
A/V mode only

Momentary
Momentary

Depends on a
display timing
Depends on a
display timing

Item

OP
code
page
02h

INPUT RESOLUTION

OP code
DAh

Parameter

Remarks

Input Resolution select
0:No mean
1:Item 1(always Auto)
2:Item 2
3:Item 3
4:Item 4
5:Item 5

ASPECT

Zoom Control

02h

70h

ZOOM

11h

2Ch

H ZOOM

11h

2Dh

(31/141)

Ex)
Item 1= AUTO
Item 2= -- /
1024x768 /
1400x1050 /
800x600 /
1280x960
Item 3= -- /
1280x768 /
1680x1050 /
1024x576 /
1600x900 /
Item 4= -- /
1360x768 /
-- /
-- /
-Item 5= -- /
1366x768
-- /
-- /
-0: No mean
1: NORMAL
2: FULL
3: WIDE
4: ZOOM
6: DYNAMIC
7: 1:1
0-89(59h): No mean
90(5Ah): 90%
91(5Bh): 91%
|
100(64h): 100%
|
300(12Ch): 300%

0-89(59h): No mean
90(5Ah): 90%
91(5Bh): 91%
|
100(64h): 100%
|
300(12Ch): 300%

Wide:
Dynamic
A/V mode only

The following
commands can also
be used.
OP code page 02h
OP code 6Fh
Parameter
0: No mean
1: 100%
2: 101%
|
201(C9h): 300%
The following
commands can also
be used.
OP code page 02h
OP code 6Ch
Parameter
0: No mean
1: 100%
2: 101%
|
201(C9h): 300%

OP code

Parameter

Remarks

V ZOOM

OP
code
page
11h

2Eh

0-89(59h): No mean
90(5Ah): 90%
91(5Bh): 91%
|
100(64h): 100%
|
300(12Ch): 300%

The following
commands can also
be used.
OP code page 02h
OP code 6Dh
Parameter
0: No mean
1: 100%
2: 101%
|
201(C9h): 300%

H POS

02h

CCh

V POS

02h

CDh

IMAGE FLIP

02h

D7h

OSD FLIP

10h

B8h

RESET
(ADJUST)

02h

CBh

VOLUME

00h

62h

BALANCE

00h

93h

00h

94h

TREBLE

00h

8Fh

BASS

00h

91h

PIP AUDIO

10h

80h

LINE OUT

10h

81h

SURROUND

02h

34h

0: Left side
|
200(C8h): Right side
0: Down side
|
200(C8h): Up side
0: No mean
1: NONE
2: H FLIP
3: V FLIP
4: 180 ROTATE
0: No mean
1: OFF
2: ON
0: No mean
3: Reset
Adjust category
0: whisper
|
100(64h): loud
O: Left
|
30(1Eh):(Center)
|
60(3Ch): Right
0: No mean
1: MONAURAL
2: STEREO
O: Min.
|
6:(Center)
|
12(0Ch): Max.
0: Min.
|
6:(Center)
|
12(0Ch): Max.
0: No mean
1: MAIN AUDIO
2: PIP AUDIO
0: No mean
1: FIXED
2: VARIABLE
0: No mean
1: OFF
2: ON

AUDI O

Item

(32/141)

Momentary

Item

OP
code
page
02h

AUDIO INPUT

AUDIO DELAY
DELAY TIME
RESET
(AUDIO)
OFF TIMER

SCHDU LE

SCHEDULE

ENABLE

DISABLE

SCHEDULE SETTINGS
DATE & TIME
DAYLIGHT SAVING
RESET
(SCHEDULE)
KEEP PIP MODE

PIP

PIP MODE

PIP SIZE
PIP POSITION

X
Y

ASPECT

OP code

Parameter

0: No mean
1: IN1
2: IN2
3: IN3
4: HDMI
6: OPTION
7: DPORT
8: DPORT2
9: DPORT3
10(0Ah): HDMI2
10h
CAh
0: No mean
1: OFF
2: ON
10h
CBh
0: (small)
|
100(64h): (large)
02h
CBh
0: No mean
4: Reset
Audio category
02h
2Bh
0: Off
1: 1 hour
|
24(18h): 24 hours
02h
E5h
0: No mean
1: No.1 Enable
|
7: No.7 Enable
02h
E6h
0: No mean
1: No.1 Disable
|
7: No.7 Disable
Refer to chapter 10
Refer to chapter 9
Refer to chapter 9 and 15
02h
CBh
0: No mean
5: Reset
Schedule category
10h
82h
0: No mean
1: OFF
2: ON
02h
72h
0: No mean
1: OFF
2: PIP
3: POP
(4: STILL)
5: PICTURE BY PICTURE
- ASPECT
6: PICTURE BY PICTURE
- Full
10h
B9h
0(small)
|
80(large)
02h
74h
0: left
|
100(64h): right
02h
75h
0: top
|
100(64h): bottom
10h
83h
0: No mean
1: NORMAL
2: FULL
3: WIDE
4: ZOOM

Remarks

2Eh

(33/141)

Momentary
1 hour/step

Momentary

Item

OP code

Parameter

MODE

OP
code
page
10h

08h

POSITION

10h

09h

SIZE

10h

0Ah

BLEND

10h

0Bh

DETECT

10h

0Ch

FADE IN

10h

0Dh

PIP INPUT(SUB INPUT)

02h

73h

RESET
(PIP)

02h

CBh

LANGUAGE

00h

68h

MENU DISPLAY TIME

00h

FCh

X

02h

38h

Y

02h

39h

0: No mean
1: OFF
2: HORIZONTAL
3: VERTICAL
0: Top/Left
|
100(64h): Bottom/Right
0-1: Do not set.
2: Narrow(2/24)
|
8: Wide(8/24)
0: No mean
1: 10%
|
10(0Ah): 100%
0: No mean
1: AUTO
2: OFF
0: No mean
1: ON
2: OFF
0: No mean
1: VGA
2: RGB/HV
3: DVI
4: HDMI (Set only)
5: VIDEO
7: S-VIDEO
12(0Ch): Y/Pb/Pr
13(0Dh): OPTION
14(0Eh): Y/Pb/Pr2
(SCART)
15(0Fh): DPORT
16(10h): DPORT2
17(11h): HDMI
18(12h): HDMI2
128(80h): DPORT3
0: No mean
6: Reset PIP
Category
0: No mean
1: ENGLISH
2: GERMAN
3: FRENCH
4: SPANISH
5: JAPANESE
6: ITALIAN
7: SWEDISH
9: RUSSIAN
14(0Eh): CHINESE
0-1: Do not set.
2: 10s
3: 15s
|
48(30h): 240s
0: Left
|
255(FFh): Right
0: Down
|
255(FFh): Up

OSD

TEXT TICKER

OSD POSITION

(34/141)

Remarks

This operation
has limitation of
selection.
Please refer to
the monitor
instruction
manual.

Momentary
OSD Language

5sec/step

Item

OP
code
page
02h

INFORMATION OSD

MULTI DIS PLAY

MONITOR
INFORMATION

OP code

Parameter

MODEL NAME

0:Disable information
OSD
3-10(0Ah):
OSD timer [seconds]
Refer to chapter 12

SERIAL
FIRMWARE1

Refer to chapter 12
Refer to chapter 16

FIRMWARE2

Refer to chapter 16

CARBON
SAVINGS

10h

CARBON
USAGE

10h

Remarks

3Dh

0 – 999(3E7h)(g)
0 – 65535(FFFFh)(kg)

Read Only

0 – 999(3E7h)(g)
0 – 65535(FFFFh)(kg)

Read Only

OSD TRANSPARENCY

02h

10h
(g)
/11h
(kg)
26h
(g)
/27h
(kg)
B8h

OSD ROTATION

02h

41h

INPUT NAME
NAME RESET
MEMO

Refer to chapter 18
10h

BAh

RESET
(OSD)

02h

CBh

MONITOR ID
GROUP ID

02h
10h

3Eh
7Fh

AUTO ID
AUTO ID RESET
IR LOCK
SETTING

MODE SELECT

Refer to chapter 17
Refer to chapter 17
10h
D4h
0:
1:
2:
3:

POWER

10h

D5h

VOLUME

10h

D6h

MIN VOL

10h

D7h

(35/141)

0:
1:
2:
0:
1:

No mean
OFF
ON
Landscape
Rotated

0:
1:
2:
0:
7:

No mean
Display a Memo
Undisplay a Memo
No mean
Reset
OSD category
1-100:ID
0: No assignment
1: Group A
2: Group B
3: Group AB
4: Group C
5: Group AC
|
1023(3FFh):Group
ABCDEFGHIJ

No mean
UNLOCK
ALL LOCK
CUSTOM LOCK

0: No mean
1: UNLOCK
2: LOCK
0: No mean
1: UNLOCK
2: LOCK
0 (whisper)
|
100(64h) (laud)

Momentary

Bit0:Group
Bit1:Group
Bit2:Group
Bit3:Group
Bit4:Group
Bit5:Group
Bit6:Group
Bit7:Group
Bit8:Group
Bit9:Group

A
B
C
D
E
F
G
H
I
J

The following
commands can also
be used.
OP code page 02h
OP code 3Fh
Parameter
0: No mean
1: NORMAL
4: LOCK

Item

TILE MATRIX

OP code

Parameter

MAX VOL

OP
code
page
10h

D8h

INPUT

10h

D9h

UNLOCK SELECT

10h

DAh

10h

DBh

10h

DCh

H MONITOR

02h

D0h

V MONITOR

02h

D1h

POSITION

02h

D2h

TILE COMP

02h

D5h

ENABLE

02h

D3h

FRAME COMP

11h

01h

AUTO

11h

02h

0 (whisper)
|
100(64h) (laud)
0: No mean
1: UNLOCK
2: LOCK
0: No mean
1: VGA
2: RGB/HV
3: DVI
4: HDMI (Set only)
5: VIDEO
6: VIDEO2
7: S-VIDEO
12(0Ch): Y/Pb/Pr
13(0Dh): OPTION
14(0Eh): Y/Pb/Pr2
(SCART)
15(0Fh): DPORT
16(10h): DPORT2
17(11h): HDMI
128(80h): DPORT3
0: No mean
1
|
10(0Ah)
0: No mean
1
|
10(0Ah)
0: No mean
1
|
100(64h)
0: No mean
1: NO
2: YES
0: No mean
1: NO
2: YES
0: No mean
1: NONE
2: AUTO
3: MANUAL
0: No mean
50(32h): 0.5F
100(64h): 1.0F
150(96h): 1.5F
200(C8h): 2.0F

MANUAL

11h

03h

(36/141)

0: No mean
25(19h): 0.25F
50(32h): 0.50F
75(4Bh): 0.75F
100(64h): 1.00F
125(7Dh): 1.25F
150(96h): 1.50F
175(Afh): 1.75F
200(C8h): 2.00F

Remarks

Number
of H-division
Number
of V-division

Available on
X464UN, X554UN,
X464UNV, X554UNS
Available on
X464UN, X554UN,
X464UNV, X554UNS
This command is
used when FRAME
COMP is set as
“AUTO”.
Available on
X464UN, X554UN,
X464UNV, X554UNS
This command is
used when FRAME
COMP is set as
“MANUAL”.

Item

OP code

Parameter

Remarks

V SCAN REVERSE

OP
code
page
11h

04h

Available on
X464UN, X554UN,
X464UNV, X554UNS

MANUAL

11h

05h

0:
1:
2:
3:
0:
1:
2:

No mean
NONE
AUTO
MANUAL
No mean
NON REVERSE
REVERSE

Available on
X464UN, X554UN,
X464UNV, X554UNS
This command is
used when V SCAN
REVERSE is set as
“MANUAL”.

TILE MATRIX MEM

10h

4Ah

AUTO TILE MATRIX SETIP

0: No mean
1: COMMON
2: INPUT
Refer to chapter 19

POWER ON DELAY

02h

D8h

LINK TO ID
VIDEO OUT SETTING
POWER INDICATOR
SETTING COPY
RESET
(MULTI DISPLAY)

DISPL AY P ROTE CTIO N

POWER SAVE
HEAT
STATUS

FAN1/2/3

BACKLIGHT
TEMPERATURE
SENSOR1/2/3

COOLING FAN
FAN CONTROL

FAN SPEED

0: Off (0sec)
|
50(32h): 50sec
10h
BCh
0: No mean
1: OFF
2: ON
10h
EAh
0: No mean
1: ON
2: OFF
02h
BEh
0: No mean
1: ON
2: OFF
Refer to Chapter 21
02h
CBh
0: No mean
8: Reset
Multi Display
Category

Momentary

Refer to Chapter 20
Read Only
02h
7Ah
Select target FAN. (7Ah)
/7Bh
0: No mean
1: FAN#1
2: FAN#2
3: FAN#3
Read status of target
FAN.(7Bh)
0: OFF
1: ON
2: ERROR
Refer to Chapter 11 (Self-diagnosis status read)
02h
79h
Return value is 2’s
Offset affects to
complement.
a selected
sensor.
(0.5°C step)
Select sensor
(Page02h
OPcode78h)
1 : SENSOR #1
2 : SENSOR #2
3 : SENSOR #3
02h
7Dh
0: No mean
1: AUTO
2: ON
10h
3Fh
0: No mean
1: HIGH
2: LOW

(37/141)

Item

OP
code
page
10h

SENSOR1

SENSOR2

SENSOR3

SCREEN SAVER

GAMMA
BACKLIGHT
MOTION

INTER
VAL
ZOOM

SIDE BORDER COLOR

EXTER NAL CONT ROL

CHANGE PASSWORD
SECURITY
RESET
(DISPLAY PROTECTION)
IP ADDRESS SETTING
MAC ADDRESS
LAN POWER
DDC/CI
PING
IP ADDRESS RESET
RESET
(EXTERNAL CONTROL)

ADVAN CED OPTI ON1

INPUT DETECT

CUSTOM
DETECT

PRIORITY1

OP code

Parameter

E0h: Set centigrade
0 – 65535(FFFFh)
E1h: Set offset from max.
value
0 – 10(0Ah)
10h
E2h/E3h
E2h: Set centigrade
0 – 65535(FFFFh)
E3h: Set offset from max.
value
0 – 10(0Ah)
10h
E4h/E5h
E4h: Set centigrade
0 – 65535(FFFFh)
E5h: Set offset from max.
value
0 – 10(0Ah)
02h
DBh
0: No mean
1: OFF
2: ON
02h
DCh
0: No mean
1: OFF
2: ON
02h
DDh
0: OFF(0s)
|
90(5Ah): 900s
10h
35h
0 : 95%
|
5 : 100%
|
10(0Ah) : 105%
02h
DFh
0: Black
|
100(64h): White
N/A
Refer to Chapter 22
02h
CBh
0: No mean
9: Reset
Display Protection
category
N/A
Refer to Chapter 23
10h
D3h
0: No mean
1: OFF
2: ON
10h
BEh
0: No mean
1: OFF
2: ON
N/A
N/A
02h
CBh
0: No mean
12(0Ch): Reset External
Control Category
02h
40h
0: FIRST DETECT
1: LAST DETECT
2: NONE
3: VIDEO DETECT
4: CUSTOM DETECT
10h
2Eh
0: No mean
1: VGA
2: RGB/HV
3: DVI
4: HDMI (Set only)

Remarks

E0h/E1h

(38/141)

10s/step

Momentary

Momentary

Item

LONG
CABLE
COMP

INPUT
CHANGE

TERMINA
L
SETTING

OP code

Parameter

PRIORITY2

OP
code
page
10h

2Fh

PRIORITY3

10h

30h

ON/OFF

10h

3Dh

SOG PEAK
GAIN
R-H.
POSITION
G-H.
POSITION
B-H.
POSITION
SYNC
TERMINATION

10h
10h
02h

37h
38h
58h

5: VIDEO
7: S-VIDEO
12(0Ch): Y/Pb/Pr
13(0Dh): OPTION
14(0Eh): Y/Pb/Pr2
(SCART)
15(0Fh): DPORT
16(10h): DPORT2
17(11h): HDMI
18(12h): HDMI2
128(80h): DPORT3:
0: No mean
1: OFF
2: ON
0 – 32(20h)
0 – 32(20h)
0 - 7

02h

59h

0 - 7

02h

5Ah

0 - 7

02h

E1h

INPUT
CHANGE

10h

86h

INPUT1

10h

CEh

INPUT2

10h

CFh

DVI MODE

02h

CFh

BNC MODE

10h

7Eh

D-SUB MODE

10h

8Eh

SCART MODE

02h

9Eh

0: No mean
1: HIGH
2: LOW
0: No mean
1: NORMAL
2: QUICK
3: SUPER
0: No mean
1: VGA
2: RGB/HV
3: DVI
4: HDMI (Set only)
5: VIDEO
7: S-VIDEO
12(0Ch): Y/Pb/Pr
13(0Dh): OPTION
14(0Eh): Y/Pb/Pr2
15(0Fh): DPORT
16(10h): DPORT2
17(11h): HDMI
18(12h): HDMI2
128(80h): DPORT3
0: No mean
1: DVI-PC
2: DVI-HD
0: No mean
1: RGB
2: COMPONENT
0: No mean
1: RGB
2: COMPONENT
0: OFF
1: ON

(39/141)

Remarks

When you set up
"SUPER", please
set up INPUT1 and
INPUT2 first.

Item

OP code

Parameter

DisplayPort

OP
code
page
10h

F1h/F2h

HDMI SIGNAL

10h

40h

DEINTERLACE

02h

25h

COLOR SYSTEM

02h

21h

OVER SCAN

02h

E3h

OPTION POWER

10h

41h

AUDIO

10h

B0h

10h

C0h

10h

C1h

10h

C2h

10h

C3h

10h

87h

STANDBY

10h

C4h

PC SOURCE

10h

C5h

RESET
(ADVANCED OPTION1)

02h

CBh

AUTO
DIMMING

AUTO BRIGHTNESS

02h

2Dh

ROOM LIGHT SENSING

10h

C8h

BACKLIGHT
SETTING

10h

C9h

Select target DPORT.
(F1h)
0: No mean
1: DPORT
2: DPORT2
3: DPORT3
Read / Write status of
target DPORT.(F2h)
0: No mean
1: 1.1a
2: 1.2
0: No mean
1: EXPAND
2: RAW
0: No mean
1: Off
2: ON
0: No mean
1: NTSC
2: PAL
3: SECAM
4: AUTO
5: 4.43NTSC
6: PAL-60
0: No mean
1: OFF
2: ON
0: OFF
1: ON
0: No mean
1: ANALOG
2: DIGITAL
0: No mean
1: OFF
2: ON
0: No mean
1: OFF
2: ON
0: No mean
1: Execute
0: No mean
1: Execute
0: No mean
1: ON
2: OFF
0: No mean
1: OFF
2: ON
0: No mean
1: AUTO
2: EXTERNAL PC
0: No mean
10(0Ah): Reset Advanced
option1 category
0: OFF
1: ON
0: No mean
1: OFF
2: MODE1
3: MODE2
0 – 100(64h)

OPTION
SETTING

INTERNAL
PC

OFF
WARNIN
G
AUTO
OFF
START
UP PC
FORCE
QUIT

120Hz

ADVAN CED

TOUCH
PANEL

MAX
LIMIT

(40/141)

Remarks

Momentary

Item

OP
code
page
10h

OP code

Parameter

33h

0 – 100(64h)

10h

34h

0 – 100(64h)

02h

B4h

10h

75h

ON/OF
F

10h

DDh

BACKL
IGHT

10h

C6h

Current Illuminance
read
0: No mean
1: DISABLE
2: AUTO OFF
4: CUSTOM
0: No mean
1: Off
2: On
0: dark
|
100(64h): light

ON/OF
F

10h

DEh

VOLUM
E

10h

C7h

ON/OF
F

10h

DFh/D0h

INPUT

10h

D0h

WAITING TIME

10h

78h

INTELLI WIRELESS DATA

10h

ECh

RESET
(ADVANCED OPTION2)

02h

CBh

FACTORY RESET

02h

CBh

IN
BRIGH
T
IN
DARK

HUMAN
SENSING

SENSI
NG LUX
HUMAN SENSING MODE

BACKLIGHT

VOLUME

INPUT SELECT

(41/141)

0: No mean
1: Off
2: On
0: whisper
|
100(64h): loud
0: No mean
1: Off
2: On
0: No mean
1: VGA
2: RGB/HV
3: DVI
4: HDMI (Set only)
5: VIDEO
7: S-VIDEO
12(0Ch): Y/Pb/Pr
13(0Dh): OPTION
14(0Eh): Y/Pb/Pr2
(SCART)
15(0Fh): DPORT
16(10h): DPORT2
17(11h): HDMI
18(12h): HDMI2
128(80h): DPORT3
30(1Eh): short
|
600(258h): long
*1step: 1sec.
0: No mean
1: OFF
2: ON
0: No mean
11(0Bh): Reset Advanced
option category
0: No mean
1: Factory Reset

Remarks

Read only

Momentary
Momentary

Item

OP code

Parameter

INPUT

OP
code
page
00h

60h

AUDIO INPUT

02h

2Eh

VOLUME UP/DOWN

00h

62h

MUTE

00h

8Dh

SCREEN MUTE

10h

B6h

MTS

02h

2Ch

SOUND

02h

34h

PICTURE MODE

02h

1Ah

ASPECT

02h

70h

0: No mean
1: VGA
2: RGB/HV
3: DVI
4: HDMI (Set only)
5: VIDEO
7: S-VIDEO
12(0Ch): Y/Pb/Pr
13(0Dh): OPTION
14(0Eh): Y/Pb/Pr2
(SCART)
15(0Fh): DPORT
16(10h): DPORT2
17(11h): HDMI
18(12h): HDMI2
128(80h): DPORT3
0: No mean
1: IN1
2: IN2
3: IN3
4: HDMI
6: OPTION
7: DPORT
8: DPORT2
9: DPORT3
10(0Ah): HDMI2
0: whisper
|
100(64h): loud
0: UNMUTE(Set only)
1: MUTE
2: UNMUTE
0: No mean
1: SCREEN MUTE ON
2: SCREEN MUTE OFF
0: No mean
1: Main
2: Sub
3: Main + Sub
0: No mean
1: Off
2: ON
0: No mean
1: sRGB
3: HIGHBRIGHT
4: STANDARD
5: CINEMA
8: CUSTOM1
9: CUSTOM2
0: No mean
1: NORMAL
2: FULL
3: WIDE
4: ZOOM
6: DYNAMIC
7: 1:1 (Off/dot by dot)

(42/141)

Remarks

This operation
requires
supported option
TV tuner.
Same as
‘SURROUND’
sRGB:
PC mode only
CINEMA:
A/V mode only

WIDE:
A/V mode only

Item

OP
code
page
02h

OP code

Parameter

72h

0:
1:
2:
3:
4:
5:

PIP INPUT

02h

73h

STILL CAPTURE

02h

76h

SIGNAL INFORMATION

02h

EAh

AUTO SETUP

00h

1Eh

TV-CHANNEL UP/DOWN

00h

8Bh

SELECT TEMPERATURE SENSOR

02h

78h

0:
1:
2:
3:

READOUT A TEMPERATURE

02h

79h

Returned value is 2's
complement.
Refer to section 6.2

READOUT CARBON FOOTPRINT
(g)

10h

10h

READOUT CARBON FOOTPRINT
(kg)

10h

11h

READOUT CARBON USAGE
(g)

10h

26h

READOUT CARBON USAGE
(kg)

10h

27h

CARBO N FO OTPR INT

TEMPE RATU RE S ENSO R

PIP ON/OFF
STILL ON/OFF

(43/141)

No mean
Off
PIP
POP
STILL
PICTUR BY PICTURE
- ASPECT
6: PICTURE BY PICTURE
- FULL
0: No mean
1: VGA
2: RGB/HV
3: DVI
4: HDMI (Set only)
5: VIDEO
7: S-VIDEO
12(0Ch): Y/Pb/Pr
13(0Dh): OPTION
14(0Eh): Y/Pb/Pr2
(SCART)
15(0Fh): DPORT
16(10h): DPORT2
17(11h): HDMI
18(12h): HDMI2
128(80h): DPORT3
0: OFF
1: CAPTURE
0: No mean
1: OFF
2: ON
0: No mean
1: Execute
0: No mean
1: UP
2: DOWN

Remarks

This operation
has limitation of
selection.
Please refer to
the monitor
instruction
manual.

Momentary

Momentary
This operation
requires
supported option
TV tuner.

No mean
SENSOR #1
SENSOR #2
SENSOR #3

0:
|
999(3E7h):
0:
|
65535(FFFFh):
0:
|
999(3E7h):
0:
|
65535(FFFFh):

Read only

Read only
Read only
Read only
Read only

7. Power control procedure
7.1 Power status read
1) The controller requests the monitor to reply a current power status.
Header
SOH-'0'-Monitor ID'0'-'A'-'0'-'6'

Message
STX-'0'-'1'-'D'-'6'-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID from which you want to get status.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message Type is "Command".
'0'-'6' (30h, 36h): Message length is 6 bytes.
Message
STX (02h): Start of Message
'0'-'1'-'D'-'6': Get power status command.
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor returns with the current power status.
Header
SOH-'0'-'0'-Monitor ID'B'-'1'-'2'

Message
STX-'0'-'2'-'0'-'0'-'D'-'6'-'0'-'0''0'-'0'-'0'-'4'-'0'-'0'-'0'-'1'-ETX

Check
code
BCC

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message Type is "Command reply".
'1'-'2' (31h, 32h): Message length is 18 bytes.
Message
STX (02h):Start of Message
'0'-'2' (30h, 32h): Reserved data
'0'-'0' (30h, 30h): Result code
00: No Error.
01: Unsupported.
'D'-'6'(44h, 36h): Display power mode code
'0'-'0' (30h, 30h): Parameter type code is "Set parameter".
'0'-'0'-'0'-'4' (30h, 30h, 30h, 34h): Power mode is 4 types.
'0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): Current power mode

0001: ON
0002: Stand-by (power save)
0003: Suspend (power save)
0004: OFF (same as IR power off)
ETX (03h): End of Message

(44/141)

Delimiter
CR

Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(45/141)

7.2 Power control
1) The controller requests the monitor to control monitor power.
Header
SOH-'0'-Monitor ID'0'-'A'-'0'-'C'

Message
STX-'C'-'2'-'0'-'3'-'D'-'6''0'-'0'-'0'-'1'-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'C (30h, 43h): Message length is 12 bytes.
Message
STX (02h): Start of Message
'C'-'2'-'0'-'3'-'D'-'6' (43h, 32h, 30h, 33h, 44h, 36h): power control command
'0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): Power mode
0001: ON
0002, 0003: Do not set.
0004: OFF (same as the power off by IR)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies a data for confirmation.
Header
SOH-'0'-'0'-Monitor ID'B'-'0'-'E'

Message
STX-'0'-'0'-'C'-'2'-'0'-'3'-'D'-'6''0'-'0'-'0'-'1'-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
'N'-'N': Message length
Note.) The maximum data length that can be written to the monitor at a time is 32bytes.
Ex.) The byte data 20h is encoded as ASCII characters '2' and '0' (32h and 30h).
Message
STX (02h): Start of Message
'0'-'0' (30h, 30h): Result code. No error.
'C'-'2’,'0'-'3'-'D'-'6' (43h, 32h, 30h, 33h, 44h, 36h): power control reply command
Ø
The monitor replies same as power control command to the controller.
'0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): Power mode
0001: ON
0002, 0003: Do not set.
0004: OFF (same as the power off by IR)
ETX (03h): End of Message

(46/141)

Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(47/141)

8. Asset Data read and write
MultiSync P403/ P463 /P553 /P703 /P801 /X464UN /X554UN /X464UNV /X554UNS have the area for to store
user’s asset data of up to 64bytes.

8.1 Asset Data Read Request and reply
This command is used in order to read Asset Data.
1) The controller requests the monitor to reply with Asset data.
Header
SOH-'0'-Monitor ID'0'-'A'-'0'-'A'

Message
STX-'C'-'0'-'0'-'B''0'-'0'-'2'-'0'-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID from which you want to get data.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'A' (30h, 41h): Message length is 10 bytes.
Message
STX (02h): Start of Message
'C'-'0'-'0'-'B' (43h, 30h, 30h, 42h): Asset read request command.
'0'-'0' (30h, 30h): Offset data from top of the Asset data.
At first set 00h: Read data from the top of Asset data area.
'2'-'0' (32h, 30h): Read out data length is 32bytes.
Secondly set 20h: Read data from the 32bytes offset point in the Asset data area.
Maximum readout length is 32bytes at a time.
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies Asset data to the controller.
Header
SOH-'0'-'0'-Monitor ID'B'-N-N

Message
STX-'C'-'1'-'0'-'B'Data(0)-Data(1)---Data(N)-ETX

Check code
BCC

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply"
N-N: Message length
Note.) This length includes STX and ETX.
Message
STX (02h): Start of Message
'C'-'1'-'0'-'B' (43h, 31h, 30h, 42h): Asset read reply command
Data(0) – Data(N): Retuned Asset data
Ex.) When Data(n) is 1234h, replying data is (31h 32h, 33h, 34h).
ETX (03h): End of Message

(48/141)

Delimiter
CR

Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(49/141)

8.2 Asset Data write
This command is used in order to write Asset Data.
1) The controller requests the monitor to write Asset data.
Header
SOH-'0'-Monitor ID'0'-'A'-N-N

Message
STX-'C'-'0'-'0'-'E'-'0'-'0'Data(0)-Data(1)---Data(N)-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID in which you want to write data.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
N-N: Message length
Note.) The maximum data length that can be written to the monitor at a time is 32bytes.
Message
STX (02h): Start of Message
'C'-'0'-'0'-'E' (43h, 30h, 30h, 45h): Asset Data writes command
'0'-'0'(30h, 30h): Offset address from top of Asset data.
00h : Write data from top of the Asset data area.
Data(0) –- Data(N): Asset data. The data must be ASCII characters strings.
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies a data for confirmation.
Header
SOH-'0'-'0'-Monitor ID'B'-N-N

Message
STX-'0'-'0'-'C'-'0'-'0'-'E'-'0'-'0'Data(0)-Data(1)---Data(N)-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
N-N: Message length
Note.) The maximum data length that can be written to the monitor at a time is 32bytes.
Message
STX (02h): Start of Message
'0'-'0': Result code. No error.
'C'-'0'-'0'-'E' (43h, 30h, 30h, 45h): Asset Data write command
'0'-'0'(30h, 30h): Offset address from top of Asset data.
00h : Write data into from top of the Asset data area.
Data(0) –- Data(N): Asset data. The data must be ASCII characters strings.
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter

(50/141)

CR (0Dh): End of packet

(51/141)

9. Date & Time read and write
9.1 Date & Time Read
This command is used in order to read the setting of Date & Time.
1) The controller requests the monitor to reply with the Date & Time.
Header
Message
Check code
Delimiter
SOH-'0'-Monitor IDSTX-'C'-'2'-'1'-'1'-ETX
BCC
CR
'0'-'A'-'0'-'6'
Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to get status.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'6'(30h, 36h): Message length
Message
STX (02h): Start of Message
'C'-'2'-'1'-'1' (43h, 32h, 31h, 31h): Date & time read request command.
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies Date & Time to the controller.
Header
SOH-'0'-'0'-Monitor ID'B'-'1'-'4'

Message
STX-'C'-'3'-'1'-'1'YY-MM-DD-WW-HH-MN-DS-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller
Monitor ID: Indicate a replying Monitor ID
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply"
'1'-'4'(31h, 34h): Message length
Message
STX (02h): Start of Message
'C'-'3'-'1'-'1' (43h, 33h, 31h, 31h): Date & Time read reply command
'YY'-'MM'-'DD'-'WW'-'HH'-'MN'-'DS': Date & Time data
YY: Year (offset 2000)
'0'-'0'(30h, 30h): 2000
|
'6'-'3'(36h, 33h): 2099 (99 = 63h)
MM: Month
'0'-'1'(30h, 31h): January
|
'0'-'C'(30h, 43h): December
DD: Day
'0'-'1'(30h, 31h): 1
|
'1'-'E'(31h, 45h): 30(=1Eh)

(52/141)

'1'-'F'(31h, 46h): 31(=1Fh)
WW: weekdays
'0'-'0'(30h,
'0'-'1'(30h,
'0'-'2'(30h,
'0'-'3'(30h,
'0'-'4'(30h,
'0'-'5'(30h,
'0'-'6'(30h,

30h):
31h):
32h):
33h):
34h):
35h):
36h):

Sunday
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday

HH: Hours
'0'-'0'(30h, 30h): 0
|
'1'-'7'(31h, 37h): 23 (=17h)
MN: Minutes
'0'-'0'(30h, 30h): 0
|
'3'-'B' (33h, 42h): 59 (=3Bh)
DS: Daylight saving (Summer time)
'0'-'0'(30h, 30h): NO
'0'-'1'(30h, 31h): YES
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(53/141)

9.2 Date & Time Write
This command is used in order to write the setting of the Date & Time.
1) The controller requests the monitor to write Date & Time.
Header
SOH-'0'-Monitor ID'0'-'A'-'1'-'2'

Message
STX-'C'-'2'-'1'-'2'YY-MM-DD-WW-HH-MN-DS-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change the setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'1'-'2'(31h, 32h): Message length
Message
STX (02h): Start of Message
'C'-'2'-'1'-'2' (43h, 32h, 31h, 32h): Date & Time write command
'YY'-'MM'-'DD'-'WW'-'HH'-'MN'-'DS': Date & Time data
YY: Year (offset 2000)
'0'-'0'(30h, 30h): 2000
|
'6'-'3'(36h, 33h): 2099 (99 = 63h)
MM: Month
'0'-'1'(30h, 31h): JANUARY
|
'0'-'C'(30h, 43h): DECEMBER
DD: Day
'0'-'1'(30h, 31h): 1
|
'1'-'E'(31h, 45h): 30(=1Eh)
'1'-'F'(31h, 46h): 31(=1Fh)
WW: weekdays
'0'-'0'(30h,
'0'-'1'(30h,
'0'-'2'(30h,
'0'-'3'(30h,
'0'-'4'(30h,
'0'-'5'(30h,
'0'-'6'(30h,

30h):
31h):
32h):
33h):
34h):
35h):
36h):

SUNDAY
MONDAY
TUESDAY
WEDNESDAY
THURSDAY
FRIDAY
SATURDAY

HH: Hours
'0'-'0'(30h, 30h): 0
|
'1'-'7'(31h, 37h): 23 (=17h)
MN: Minutes
'0'-'0'(30h, 30h): 0
|
'3'-'B' (33h, 42h): 59 (=3Bh)
DS: Daylight saving (Summer time)
'0'-'0'(30h, 30h): NO
'0'-'1'(30h, 31h): YES
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
(54/141)

Delimiter
CR (0Dh): End of packet
2) The monitor replies a data for confirmation.
Header
Message
SOH-'0'-'0'-Monitor IDSTX-'C'-'3'-'1'-'2'-ST'B'-'1'-'6'
YY-MM-DD-WW-HH-MN-DS-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
'1'-'6'(31h, 36h): Message length
Message
STX (02h): Start of Message
'C'-'3'-'1'-'2' (43h, 33h, 31h, 32h): Date & Time write reply command
ST: Date & Time Status command
'0'-'0'(30h, 30h): No error
'0'-'1'(30h, 31h): Error
'YY'-'MM'-'DD'-'WW'-'HH'-'MN'-'DS': Date & Time data
YY: Year (offset 2000)
'0'-'0'(30h, 30h): 2000
|
'6'-'3'(36h, 33h): 2099 (99 = 63h)
MM: Month
'0'-'1'(30h, 31h): JANUARY
|
'0'-'C'(30h, 43h): DECEMBER
DD: Day
'0'-'1'(30h, 31h): 1
|
'1'-'E'(31h, 45h): 30(=1Eh)
'1'-'F'(31h, 46h): 31(=1Fh)
WW: weekdays
'0'-'0'(30h,
'0'-'1'(30h,
'0'-'2'(30h,
'0'-'3'(30h,
'0'-'4'(30h,
'0'-'5'(30h,
'0'-'6'(30h,

30h):
31h):
32h):
33h):
34h):
35h):
36h):

SUNDAY
MONDAY
TUESDAY
WEDNESDAY
THURSDAY
FRIDAY
SATURDAY

HH: Hours
'0'-'0'(30h, 30h): 0
|
'1'-'7'(31h, 37h): 23 (=17h)
MN: Minutes
'0'-'0'(30h, 30h): 0
|
'3'-'B' (33h, 42h): 59 (=3Bh)
DS: Daylight saving (Summer time)
'0'-'0'(30h, 30h): NO
'0'-'1'(30h, 31h): YES
ETX (03h): End of Message

(55/141)

Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(56/141)

10. Schedule read and write
10.1 Schedule Read

This command is used in order to read the setting of the Schedule.
1) The controller requests the monitor to read Schedule.
Header
Message
SOH-'0'-Monitor IDSTX-'C'-'2'-'2'-'1'-PG-ETX
'0'-'A'-'0'-'8'

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to get status.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'8'(30h, 38h): Message length
Message
STX (02h): Start of Message
'C'-'2'-'2'-'1' (43h, 32h, 32h, 31h): Schedule read request command.
PG: Program No.
Ø
The data must be ASCII characters strings.
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies Schedule to the controller.
Header
SOH-'0'-'0'-Monitor ID'B'-'2'-'6'

Message
STX-'C'-'3'-'2'-'1'-PG-ON HOUR-ON MINOFF HOUR-OFF MIN-INPUT-WD-FL-P MODEEXT1-EXT2-EXT3-EXT4-EXT5-EXT6-EXT7-ETX

Check
code
BCC

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
'2'-'6'(32h, 36h): Message length
Message
STX (02h): Start of Message
'C'-'3'-'2'-'1' (43h, 33h, 32h, 31h): Schedule read reply command
PG-ON HOURS-ON MIN-OFF HOURS-OFF MIN-INPUT-WD-FL-P MODEEXT1-EXT2-EXT3-EXT4-EXT5-EXT6-EXT7: Schedule data
PG: Program No.
'0'-'0'(30h, 30h): Program No.1
|
'0'-'6'(30h, 36h): Program No.7
ON_HOUR: Turn on
'0'-'0'(30h,
|
'1'-'7'(31h,
'1'-'8'(31h,

time (hour)
30h): 00
37h): 23 (=17h)
38h): ON timer isn't set.
(57/141)

Delimiter
CR

ON_MIN: Turn on time (minute)
'0'-'0'(30h, 30h): 0
|
'3'-'B'(33h, 42h): 59
'3'-'C'(33h, 43h): On timer isn't set.
OFF_HOUR: Turn off time (hour)
'0'-'0'(30h, 30h): 00
|
'1'-'7'(31h, 37h): 23 (=17h)
'1'-'8'(31h, 38h): Off timer isn't set.
OFF_MIN: Turn off time
'0'-'0'(30h, 30h):
|
'3'-'B'(33h, 42h):
'3'-'C'(33h, 43h):
INPUT: Timer input
'0'-'0'(30h,30h):
'0'-'1'(30h,31h):
'0'-'2'(30h,32h):
'0'-'3'(30h,33h):
'0'-'5'(30h,35h):
'0'-'7'(30h,37h):
'0'-'C'(30h,43h):
'0'-'D'(30h,44h):
'0'-'E'(30h,45h):
'0'-'F'(30h,46h):
'1'-'0'(31h,30h):
'1'-'1'(31h,31h):
'1'-'2'(31h,32h):
'8'-'0'(38h,30h):

(minute)
0
59 (=3Bh)
Off timer isn’t set.

No mean (works on last memory)
VGA
RGB/HV
DVI
VIDEO
S-VIDEO
Y/Pb/Pr
OPTION
Y/Pb/Pr2(SCART)
DPORT
DPORT2
HDMI
HDMI2
DPORT3

WD: Week setting
bit 0: MONDAY
bit 1: TUESDAY
bit 2: WEDNESDAY
bit 3: THURSDAY
bit 4: FRIDAY
bit 5: SATURDAY
bit 6: SUNDAY
EX.
'0'-'1'(30h,
'0'-'4'(30h,
'0'-'F'(30h,
'7'-'F'(37h,

31h):
34h):
46h):
46h):

MONDAY
TUESDAY
MONDAY, TUESDAY, WEDNESDAY and THURSDAY
MONDAY to SUNDAY

FL: Option
bit 0: 0:once 1:Everyday
bit 1: 0:once 1:Every week
bit 2: 0:Disable 1:Enable
EX.
'0'-'1'(30h, 31h): Disable, Everyday
'0'-'4'(30h, 34h): Enable, once
P MODE: Picture mode
'0'-'0'(30h,30h):
'0'-'1'(30h,31h):
'0'-'3'(30h,33h):
'0'-'4'(30h,34h):
'0'-'5'(30h,34h):
'0'-'D'(30h,44h):
'0'-'E'(30h,45h):

No mean (works on last memory)
sRGB
HIGHBRIGHT
STANDARD
CINEMA
CUSTOM1
CUSTOM2

(58/141)

EXT1: Extension1
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT2: Extension 2
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT3: Extension 3
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT4: Extension 4
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT5: Extension 5
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT6: Extension 6
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT7: Extension 7
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(59/141)

***Following command also can be used for to keep backward compatibility, in order to
read the setting of the Schedule.
1) The controller requests the monitor to read Schedule.
Header
Message
SOH-'0'-Monitor IDSTX-'C'-'2'-'1'-'3'-PG-ETX
'0'-'A'-'0'-'8'

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to get status.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'8'(30h, 38h): Message length
Message
STX (02h): Start of Message
'C'-'2'-'1'-'3' (43h, 32h, 31h, 33h): Schedule read request command.
PG: Program No.
Ø
The data must be ASCII characters strings.
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies Schedule to the controller.
Header
SOH-'0'-'0'-Monitor ID'B'-'1'-'6'

Message
STX-'C'-'3'-'1'-'3'-PG-ON HOUR-ON MINOFF HOUR-OFF MIN-INPUT-WD-FL-ETX

Check code
BCC

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
'1'-'6'(31h, 36h): Message length
Message
STX (02h): Start of Message
'C'-'3'-'1'-'3' (43h, 33h, 31h, 33h): Schedule read reply command
PG-ON HOURS-ON MIN-OFF HOURS-OFF MIN-INPUT-WD-FL: Schedule data
PG: Program No.
'0'-'0'(30h, 30h): Program No.1
|
'0'-'6'(30h, 36h): Program No.7
ON_HOUR: Turn on
'0'-'0'(30h,
|
'1'-'7'(31h,
'1'-'8'(31h,

time (hour)
30h): 00
37h): 23 (=17h)
38h): ON timer isn't set.

(60/141)

Delimiter
CR

ON_MIN: Turn on time (minute)
'0'-'0'(30h, 30h): 0
|
'3'-'B'(33h, 42h): 59
'3'-'C'(33h, 43h): On timer isn't set.
OFF_HOUR: Turn off time (hour)
'0'-'0'(30h, 30h): 00
|
'1'-'7'(31h, 37h): 23 (=17h)
'1'-'8'(31h, 38h): Off timer isn't set.
OFF_MIN: Turn off time
'0'-'0'(30h, 30h):
|
'3'-'B'(33h, 42h):
'3'-'C'(33h, 43h):

(minute)
0
59 (=3Bh)
Off timer isn’t set.

INPUT: Timer input
'0'-'0'(30h, 30h): DVI
'0'-'1'(30h, 31h): VGA
'0'-'2'(30h, 32h): RGB/HV
'0'-'3'(30h, 33h): Y/Pb/Pr
'0'-'4'(30h, 34h): VIDEO
'0'-'5'(30h, 35h): S-VIDEO
'0'-'7'(30h,30h): No mean (Works on last memory)
WD: Week setting
bit 0: MONDAY
bit 1: TUESDAY
bit 2: WEDNESDAY
bit 3: THURSDAY
bit 4: FRIDAY
bit 5: SATURDAY
bit 6: SUNDAY
EX.
'0'-'1'(30h,
'0'-'4'(30h,
'0'-'F'(30h,
'7'-'F'(37h,

31h):
34h):
46h):
46h):

MONDAY
TUESDAY
MONDAY, TUESDAY, WEDNESDAY and THURSDAY
MONDAY to SUNDAY

FL: Option
bit 0: 0:once 1:Everyday
bit 1: 0:once 1:Every week
bit 2: 0:Disable 1:Enable
EX.
'0'-'1'(30h, 31h): Disable, Everyday
'0'-'4'(30h, 34h): Enable, once
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(61/141)

10.2 Schedule Write
This command is used in order to write the setting of the Schedule.
1) The controller requests the monitor to write Schedule.
Header
SOH-'0'-Monitor ID'0'-'A'-'2'-'6'

Message
STX-'C'-'2'-'2'-'2'-PG-ON HOUR-ON MINOFF HOUR-OFF MIN-INPUT-WD-FL-P MODEEXT1-EXT2-EXT3-EXT4-EXT5-EXT6-EXT7-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'2'-'6'(32h, 36h): Message length.
Message
STX (02h): Start of Message
'C'-'2'-'2'-'2' (43h, 32h, 32h, 32h): Schedule writes command
PG-ON HOURS-ON MIN-OFF HOURS-OFF MIN-INPUT-WD-FL-P MODE
EXT1-EXT2-EXT3-EXT4-EXT5-EXT6-EXT7: Schedule data
PG: Program No.
'0'-'0'(30h, 30h): Program No.1
|
'0'-'6'(30h, 36h): Program No.7
ON_HOUR: Turn on
'0'-'0'(30h,
|
'1'-'7'(31h,
'1'-'8'(31h,

time (hour)
30h): 00
37h): 23 (=17h)
38h): ON timer isn't set.

ON_MIN: Turn on time (minute)
'0'-'0'(30h, 30h): 0
|
'3'-'B'(33h, 42h): 59
'3'-'C'(33h, 43h): On timer isn’t set.
OFF_HOUR: Turn off time (hour)
'0'-'0'(30h, 30h): 00
|
'1'-'7'(31h, 37h): 23 (=17h)
'1'-'8'(31h, 38h): Off timer isn't set.
OFF_MIN: Turn off time
'0'-'0'(30h, 30h):
|
'3'-'B'(33h, 42h):
'3'-'C'(33h, 43h):

(minute)
0
59 (=3Bh)
Off timer isn’t set.

Note:
* The same time as ON time and OFF time cannot be set.
* Set '1'-'8' to ON/OFF_HOUR and '3'-'C' to ON/OFF_MIN, when ON/OFF time is deleted.
INPUT: Timer input
'0'-'0'(30h,30h):
'0'-'1'(30h,31h):
'0'-'2'(30h,32h):
'0'-'3'(30h,33h):
'0'-'5'(30h,35h):
'0'-'7'(30h,37h):
'0'-'C'(30h,43h):
'0'-'D'(30h,44h):

No mean (works on last memory)
VGA
RGB/HV
DVI
VIDEO
S-VIDEO
Y/Pb/Pr
OPTION
(62/141)

'0'-'E'(30h,45h): Y/Pb/Pr2(SCART)
'0'-'F'(30h,46h): DPORT
'1'-'0'(31h,30h): DPORT2
'1'-'1'(31h,31h): HDMI
'1'-'2'(31h,32h): HDMI2
'8'-'0'(38h,30h): DPORT3
* Please select active input on your system (setting).
* If you select inactive input here, the input change execution will be ignored.
WD: Week setting
bit 0: MONDAY
bit 1: TUESDAY
bit 2: WEDNESDAY
bit 3: THURSDAY
bit 4: FRIDAY
bit 5: SATURDAY
bit 6: SUNDAY
EX.
'0'-'1'(30h,
'0'-'4'(30h,
'0'-'F'(30h,
'7'-'F'(37h,

31h):
34h):
46h):
46h):

MONDAY
TUESDAY
MONDAY, TUESDAY, WEDNESDAY and THURSDAY
MONDAY to SUNDAY

FL: Option
bit 0: 0:once 1:Everyday
bit 1: 0:once 1:Every week
bit 2: 0:Disable 1:Enable
* When bit 0 and bit 1 are '1', it behaves as Everyday.
EX.
'0'-'1'(30h, 31h): Disable, Everyday
'0'-'4'(30h, 34h): Enable, once
P MODE: Picture mode
'0'-'0'(30h,30h): No mean (works on last memory)
'0'-'1'(30h,31h): sRGB
'0'-'3'(30h,33h): HiGHBRIGHT
'0'-'4'(30h,34h): STANDARD
'0'-'5'(30h,34h): CINEMA
'0'-'D'(30h,44h): CUSTOM1
'0'-'E'(30h,45h): CUSTOM2
* Please select active picture mode on your system (setting).
* If you select inactive picture mode here, the input change execution will be ignored.
EXT1: Extension1
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT2: Extension 2
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT3: Extension 3
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT4: Extension 4
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT5: Extension 5
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT6: Extension 6
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT7: Extension 7
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
ETX (03h): End of Message

(63/141)

Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies a data for confirmation.
Header
Message
SOH-'0'-'0'-Monitor ID'B'-'2'-'8'

STX-'C'-'3'-'2'-'2'-ST-PG-ON HOUR-ON MINOFF HOUR-OFF MIN-INPUT-WD-FL-P MODEEXT1-EXT2-EXT3-EXT4-EXT5-EXT6-EXT7-ETX

Check
code
BCC

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
'2'-'8'(32h, 38h): Message length
Message
STX (02h): Start of Message
'C'-'3'-'2'-'2' (43h, 33h, 32h, 32h): Schedule writes reply command
ST: Schedule Status command
'0'-'0'(30h, 30h): No error
'0'-'1'(30h, 31h): Error
PG-ON HOURS-ON MIN-OFF HOURS-OFF MIN-INPUT-WD-FL-P MODE
EXT1-EXT2-EXT3-EXT4-EXT5-EXT6-EXT7: Schedule data
PG: Program No.
'0'-'0'(30h, 30h): Program No.1
|
'0'-'6'(30h, 36h): Program No.7
ON_HOUR: Turn on
'0'-'0'(30h,
|
'1'-'7'(31h,
'1'-'8'(31h,

time (hour)
30h): 00
37h): 23 (=17h)
38h): ON timer isn't set.

ON_MIN: Turn on time (minute)
'0'-'0'(30h, 30h): 0
|
'3'-'B'(33h, 42h): 59
'3'-'C'(33h, 43h): On timer isn’t set.
OFF_HOUR: Turn off time (hour)
'0'-'0'(30h, 30h): 00
|
'1'-'7'(31h, 37h): 23 (=17h)
'1'-'8'(31h, 38h): Off timer isn't set.
OFF_MIN: Turn off time
'0'-'0'(30h, 30h):
|
'3'-'B'(33h, 42h):
'3'-'C'(33h, 43h):
INPUT: Timer input
'0'-'0'(30h,30h):
'0'-'1'(30h,31h):
'0'-'2'(30h,32h):
'0'-'3'(30h,33h):
'0'-'5'(30h,35h):
'0'-'7'(30h,37h):
'0'-'C'(30h,43h):

(minute)
0
59 (=3Bh)
Off timer isn’t set.

No mean (works on last memory)
VGA
RGB/HV
DVI
VIDEO
S-VIDEO
Y/Pb/Pr
(64/141)

Delimiter
CR

'0'-'D'(30h,44h):
'0'-'E'(30h,45h):
'0'-'F'(30h,46h):
'1'-'0'(31h,30h):
'1'-'1'(31h,31h):
'1'-'2'(31h,32h):
'8'-'0'(38h,30h):

OPTION
Y/Pb/Pr2(SCART)
DPORT
DPORT2
HDMI
HDMI2
DPORT3

WD: Week setting
bit 0: MONDAY
bit 1: TUESDAY
bit 2: WEDNESDAY
bit 3: THURSDAY
bit 4: FRIDAY
bit 5: SATURDAY
bit 6: SUNDAY
EX.
'0'-'1'(30h,
'0'-'4'(30h,
'0'-'F'(30h,
'7'-'F'(37h,
FL: Option
bit 0:
bit 1:
bit 2:
* When

31h):
34h):
46h):
46h):

MONDAY
TUESDAY
MONDAY, TUESDAY, WEDNESDAY and THURSDAY
MONDAY to SUNDAY

0:once 1:Everyday
0:once 1:Every week
0:Disable 1:Enable
bit 0 and bit 1 are '1', it behaves as Everyday.

EX.
'0'-'1'(30h, 31h): Disable, Everyday
'0'-'4'(30h, 34h): Enable, once
P MODE: Picture mode
'0'-'0'(30h,30h):
'0'-'1'(30h,31h):
'0'-'3'(30h,33h):
'0'-'4'(30h,34h):
'0'-'5'(30h,34h):
'0'-'D'(30h,44h):
'0'-'E'(30h,45h):

No mean (works on last memory)
sRGB
HIGHBRIGHT
STANDARD
CINEMA
CUSTOM1
CUSTOM2

EXT1: Extension1
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT2: Extension 2
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT3: Extension 3
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT4: Extension 4
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT5: Extension 5
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT6: Extension 6
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT7: Extension 7
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.

(65/141)

Delimiter
CR (0Dh): End of packet
3) The controller requests the monitor to write Enable/Disable Schedule.
Header
Message
Check code
SOH-'0'-Monitor IDSTX-'C'-'2'-'1'-'5'-PG-EN-ETX
BCC
'0'-'A'-'0'-'A'

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'A'(30h, 41h): Message length
Message
STX (02h): Start of Message
'C'-'2'-'1'-'5' (43h, 32h, 31h, 35h): Enable/Disable Schedule writes command
PG-EN: Enable/Disable Schedule data
PG: Program No.
'0'-'0'(30h, 30h): Program No.1
|
'0'-'6'(30h, 36h): Program No.7
EN: Enable /Disable
'0'-'0'(30h, 30h): Disable
'0'-'1'(30h, 31h): Enable
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
4) The monitor replies a data for confirmation.
Header
Message
SOH-'0'-'0'-Monitor IDSTX-'C'-'3'-'1'-'5'-ST-PG-EN-ETX
'B'-'0'-'C'

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
'0'-'C' (30h, 43h): Message length
Message
STX (02h): Start of Message
'C'-'3'-'1'-'5' (43h, 33h, 31h, 35h): Enable/Disable Schedule writes reply command
ST: Enable/Disable Schedule Status command
'0'-'0'(30h, 30h): No error
'0'-'1'(30h, 31h): Error
PG-EN: Enable/Disable Schedule data
PG: Program No.
'0'-'0'(30h, 30h): Program No.1
|
'0'-'6'(30h, 36h): Program No.7
EN: Enable /Disable
'0'-'0'(30h, 30h): Disable

(66/141)

'0'-'1'(30h, 31h): Enable
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(67/141)

***Following command also can be used for to keep backward compatibility, in order to
write the setting of the Schedule.
1) The controller requests the monitor to write Schedule.
Header
SOH-'0'-Monitor ID'0'-'A'-'1'-'6'

Message
STX-'C'-'2'-'1'-'4'-PG-ON HOUR-ON MINOFF HOUR-OFF MIN-INPUT-WD-FL-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'1'-'6'(31h, 36h): Message length.
Message
STX (02h): Start of Message
'C'-'2'-'1'-'4' (43h, 32h, 31h, 34h): Schedule writes command
PG-ON HOURS-ON MIN-OFF HOURS-OFF MIN-INPUT-WD-FL: Schedule data
PG: Program No.
'0'-'0'(30h, 30h): Program No.1
|
'0'-'6'(30h, 36h): Program No.7
ON_HOUR: Turn on
'0'-'0'(30h,
|
'1'-'7'(31h,
'1'-'8'(31h,

time (hour)
30h): 00
37h): 23 (=17h)
38h): ON timer isn't set.

ON_MIN: Turn on time (minute)
'0'-'0'(30h, 30h): 0
|
'3'-'B'(33h, 42h): 59
'3'-'C'(33h, 43h): On timer isn’t set.
OFF_HOUR: Turn off time (hour)
'0'-'0'(30h, 30h): 00
|
'1'-'7'(31h, 37h): 23 (=17h)
'1'-'8'(31h, 38h): Off timer isn't set.
OFF_MIN: Turn off time
'0'-'0'(30h, 30h):
|
'3'-'B'(33h, 42h):
'3'-'C'(33h, 43h):

(minute)
0
59 (=3Bh)
Off timer isn’t set.

INPUT: Timer input
'0'-'0'(30h, 30h): DVI
'0'-'1'(30h, 31h): VGA
'0'-'2'(30h, 32h): RGB/HV
'0'-'3'(30h, 33h): Y/Pb/Pr
'0'-'4'(30h, 34h): VIDEO
'0'-'5'(30h, 35h): S-VIDEO
'0'-'7'(30h, 37h): (Works on last memory)
* Please select active input on your system (setting).
* If you select inactive input here, the input change execution will be ignored.
WD: Week setting
bit 0: MONDAY
bit 1: TUESDAY
(68/141)

bit
bit
bit
bit
bit

2:
3:
4:
5:
6:

WEDNESDAY
THURSDAY
FRIDAY
SATURDAY
SUNDAY

EX.
'0'-'1'(30h,
'0'-'4'(30h,
'0'-'F'(30h,
'7'-'F'(37h,

31h):
34h):
46h):
46h):

MONDAY
TUESDAY
MONDAY, TUESDAY, WEDNESDAY and THURSDAY
MONDAY to SUNDAY

FL: Option
bit 0: 0:once 1:Everyday
bit 1: 0:once 1:Every week
bit 2: 0:Disable 1:Enable
* When bit 0 and bit 1 are '1', it behaves as Everyday.
EX.
'0'-'1'(30h, 31h): Disable, Everyday
'0'-'4'(30h, 34h): Enable, once
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies a data for confirmation.
Header
SOH-'0'-'0'-Monitor ID'B'-'1'-'8'

Message

STX-'C'-'3'-'1'-'4'-ST-PG-ON HOUR-ON MINOFF HOUR-OFF MIN-INPUT-WD-FL-ETX

Check
code
BCC

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
'1'-'8'(31h, 38h): Message length
Message
STX (02h): Start of Message
'C'-'3'-'1'-'4' (43h, 33h, 31h, 34h): Schedule writes reply command
ST: Schedule Status command
'0'-'0'(30h, 30h): No error
'0'-'1'(30h, 31h): Error
PG-ON HOURS-ON MIN-OFF HOURS-OFF MIN-INPUT-WD-FL: Schedule data
PG: Program No.
'0'-'0'(30h, 30h): Program No.1
|
'0'-'6'(30h, 36h): Program No.7
ON_HOUR: Turn on
'0'-'0'(30h,
|
'1'-'7'(31h,
'1'-'8'(31h,

time (hour)
30h): 00
37h): 23 (=17h)
38h): ON timer isn't set.

ON_MIN: Turn on time (minute)
'0'-'0'(30h, 30h): 0
|
'3'-'B'(33h, 42h): 59
(69/141)

Delimiter
CR

'3'-'C'(33h, 43h): On timer isn’t set.
OFF_HOUR: Turn off time (hour)
'0'-'0'(30h, 30h): 00
|
'1'-'7'(31h, 37h): 23 (=17h)
'1'-'8'(31h, 38h): Off timer isn't set.
OFF_MIN: Turn off time
'0'-'0'(30h, 30h):
|
'3'-'B'(33h, 42h):
'3'-'C'(33h, 43h):

(minute)
0
59 (=3Bh)
Off timer isn’t set.

INPUT: Timer input
'0'-'0'(30h, 30h): DVI
'0'-'1'(30h, 31h): VGA
'0'-'2'(30h, 32h): RGB/HV
'0'-'3'(30h, 33h): Y/Pb/Pr
'0'-'4'(30h, 34h): VIDEO
'0'-'5'(30h, 35h): S-VIDEO
'0'-'7'(30h,30h): No mean (Works on last memory)
WD: Week setting
bit 0: MONDAY
bit 1: TUESDAY
bit 2: WEDNESDAY
bit 3: THURSDAY
bit 4: FRIDAY
bit 5: SATURDAY
bit 6: SUNDAY
EX.
'0'-'1'(30h,
'0'-'4'(30h,
'0'-'F'(30h,
'7'-'F'(37h,
FL: Option
bit 0:
bit 1:
bit 2:
* When

31h):
34h):
46h):
46h):

MONDAY
TUESDAY
MONDAY, TUESDAY, WEDNESDAY and THURSDAY
MONDAY to SUNDAY

0:once 1:Everyday
0:once 1:Every week
0:Disable 1:Enable
bit 0 and bit 1 are '1', it behaves as Everyday.

EX.
'0'-'1'(30h, 31h): Disable, Everyday
'0'-'4'(30h, 34h): Enable, once
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
3) The controller requests the monitor to write Enable/Disable Schedule.
Header
Message
Check code
Delimiter
SOH-'0'-Monitor IDSTX-'C'-'2'-'1'-'5'-PG-EN-ETX
BCC
CR
'0'-'A'-'0'-'A'
Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
(70/141)

'A' (41h): Message type is "Command".
'0'-'A'(30h, 41h): Message length
Message
STX (02h): Start of Message
'C'-'2'-'1'-'5' (43h, 32h, 31h, 35h): Enable/Disable Schedule writes command
PG-EN: Enable/Disable Schedule data
PG: Program No.
'0'-'0'(30h, 30h): Program No.1
|
'0'-'6'(30h, 36h): Program No.7
EN: Enable /Disable
'0'-'0'(30h, 30h): Disable
'0'-'1'(30h, 31h): Enable
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
4) The monitor replies a data for confirmation.
Header
Message
SOH-'0'-'0'-Monitor IDSTX-'C'-'3'-'1'-'5'-ST-PG-EN-ETX
'B'-'0'-'C'

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
'0'-'C' (30h, 43h): Message length
Message
STX (02h): Start of Message
'C'-'3'-'1'-'5' (43h, 33h, 31h, 35h): Enable/Disable Schedule writes reply command
ST: Enable/Disable Schedule Status command
'0'-'0'(30h, 30h): No error
'0'-'1'(30h, 31h): Error
PG-EN: Enable/Disable Schedule data
PG: Program No.
'0'-'0'(30h, 30h): Program No.1
|
'0'-'6'(30h, 36h): Program No.7
EN: Enable /Disable
'0'-'0'(30h, 30h): Disable
'0'-'1'(30h, 31h): Enable
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(71/141)

11. Self diagnosis

11.1 Self-diagnosis status read
This command is used in order to read the Self-diagnosis status.
1) The controller requests the monitor to read Self-diagnosis status.
Header
Message
Check code
Delimiter
SOH-'0'-Monitor IDSTX-'B'-'1'-ETX
BCC
CR
'0'-'A'-'0'-'4'
Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID which you want to get status.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'4'(30h, 34h): Message length
Message
STX (02h): Start of Message
'B'-'1' (42h, 31h): Self-diagnosis command
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies a result of the self-diagnosis.
Header
SOH-'0'-'0'-Monitor ID'B'-N-N

Message
STX-'A'-'1'ST(0)-ST(1) --------ST(n)-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
N-N: Message length
Note.) The maximum data length that can be written to the monitor at a time is 32bytes.
Ex.) The byte data 20h is encoded as ASCII characters '2' and '0' (34h and 30h).
Message
STX (02h): Start of Message
'A'-'1' (41h, 31h): Application Test Report reply command
ST: Result of self-tests
'0'-'0'(30h, 30h):00: Normal
'7'-'0'(37h, 30h):70: Standby-power +3.3V abnormality
'7'-'1'(37h, 31h):71: Standby-power +5V abnormality
'7'-'2'(37h, 32h):72: Panel-power +12V abnormality
'7'-'8'(37h, 38h):78: Inverter power/Option slot2 power +24V Abnormality
'8'-'0'(38h, 30h):80: Cooling fan-1 abnormality
'8'-'1'(38h, 31h):81: Cooling fan-2 abnormality
('8'-'2'(38h, 32h):82: Cooling fan-3 abnormality)
'9'-'1'(39h, 31h):91: LED Backlight abnormality
'A'-'0'(41h, 30h):A0: Temperature abnormality – shutdown
'A'-'1'(41h, 31h):A1: Temperature abnormality – half brightness
'A'-'2'(41h, 32h):A2: SENSOR reached at the temperature that the user had specified.
'B'-'0'(42h, 30h):B0: No signal
(72/141)

'D'-'0'(44h, 30h):D0: PROOF OF PLAY buffer reduction
'E'-'0'(45h, 30h):E0: System error
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(73/141)

12. Serial No. & Model Name Read
12.1 Serial No. Read

This command is used in order to read a serial number.
1) The controller requests the monitor to read a serial number.
Header
Message
Check code
SOH-'0'-Monitor IDSTX-'C'-'2'-'1'-'6'-ETX
BCC
'0'-'A'-'0'-'6'

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID which you want to get serial number.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'6'(30h, 36h): Message length
Message
STX (02h): Start of Message
'C'-'2'-'1'-'6' (43h, 32h, 31h, 36h): Serial No. command
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

2) The monitor replies the serial No. data to the controller.
Header
SOH-'0'-'0'-Monitor ID'B'-N-N

Message
STX-'C'-'3'-'1'-'6'Data(0)-Data(1)---Data(n)-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
N-N: Message length
Note.) The maximum data length that can be returned from the monitor at a time is
32bytes.
Ex.) The byte data 20h is encoded as ASCII characters '2' and '0' (32h and 30h).
Message
STX (02h): Start of Message
'C'-'3'-'1'-'6' (41h, 33h, 31h, 36h): Serial No. reply command
Data(0)-Data(1)----Data(n):Serial Number
Ø
The byte data 20h is encoded as ASCII characters '2' and '0' (32h and 30h).
Ex.) Foe example when receiveing Serial Number data 33h 31h 33h 32h 33h 33h 33h 34h
Step1: Serial Number data is encoded as character string.
Example:
33h 31h 33h 32h 33h 33h 33h 34h -> '3','1','3','2','3','3','3','4'
Step2: Decode pairs of ASCII characters to hexadecimal values.
Example:
'3','1','3','2','3','3','3','4' -> 31h 32h 33h 34h
Step3: Byte data represents the ASCII string data.
Example:
31h 32h 33h 34h -> "1234"
Result: Serial Number is "1234".

(74/141)

Note: No null termination character is sent.
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(75/141)

12.2 Model Name Read
This command is used in order to read the Model Name.
1) The controller requests the monitor to read Model Name.
Header
Message
Check code
SOH-'0'-Monitor IDSTX-'C'-'2'-'1'-'7'-ETX
BCC
'0'-'A'-'0'-'6'

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID which you want to get Model Name.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'6'(30h, 36h): Message length
Message
STX (02h): Start of Message
'C'-'2'-'1'-'7' (43h, 32h, 31h, 37h): Model Name command
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies the model name data to the controller.
Header
Message
SOH-'0'-'0'-Monitor IDSTX-'C'-'3'-'1'-'7''B'-N-N
Data(0) -Data(1)—----Data(n)-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
N-N: Message length
Note.) The maximum data length that can be returned from the monitor at a time is
32bytes.
Ex.) The byte data 20h is encoded as ASCII characters '2' and '0' (32h and 30h).
Message
STX (02h): Start of Message
'C'-'3'-'1'-'7' (43h, 33h, 31h, 37h): Model Name reply Command
Data(0) -Data(1)----Data(n):Model name
Ø
The byte data 20h is encoded as ASCII characters '2' and '0' (32h and 30h).
Ex.) Foe example when receiving Model Name data 35h 30h 33h 34h 33h 30h 33h 33h
Step1: Model Name data is encoded character string.
Example:
35h 30h 33h 34h 33h 30h 33h 33h -> '5','0','3','4','3','0','3','3'
Step2: Decode pairs of ASCII characters to hexadecimal values.
Example:
'5','0','3','4','3','0','3','3' -> 50h 34h 30h 33h
Step3: Byte data represents the ASCII string data.
Example:
50h 34h 30h 33h -> "P403"
Result: Model Name is "P403".
Note: No null termination character is sent.
ETX (03h): End of Message
Check code
BCC: Block Check Code

(76/141)

Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(77/141)

13. Security Lock
13.1 Security Lock Control
This command sets the condition of security lock function to "LOCK" or "UNLOCK".
If security pass codes 1st to 4th are matched with monitor resisted pass codes, then this command
is executed, and reply no error status and a new condition.
If codes aren't matched with them then setting isn't changed, and reply error status and a current
condition.
If the monitor receives this command while waiting for Pass codes inputs, then it only checks Pass
cords (and releases image muting if Pass codes are OK) and doesn't apply "EN" parameter.
1) The controller requests the monitor to set the condition of security lock.
Header
Message
Check code
Delimiter
SOH-'0'-MonitorIDSTX-'C'-'2'-'1'-'D'BCC
CR
'0'-'A'-'1'-'0'
EN-P1-P2-P3-P4-ETX
Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'1'-'0'(31h, 30h): Message length
Message
STX (02h): Start of Message
'C'-'2'-'1'-'D' (43h, 32h, 31h, 44h): Security Lock Control command
EN-P1-P2-P3-P4: Lock condition control data
EN: Enable /Disable
'0'-'0'(30h, 30h): Disable
'0'-'1'(30h, 31h): Enable
P1: Security Pass code 1st
'0'-'0'(30h, 30h): "0"
|
'0'-'9'(30h, 39h): "9"
P2: Security Pass code 2nd
'0'-'0'(30h, 30h): "0"
|
'0'-'9'(30h, 39h): "9"
P3: Security Pass code 3rd
'0'-'0'(30h, 30h): "0"
|
'0'-'9'(30h, 39h): "9"
P4: Security Pass code 4th
'0'-'0'(30h, 30h): "0"
|
'0'-'9'(30h, 39h): "9"
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(78/141)

2) The monitor replies the result to the controller.
Header
SOH-'0'-'0'-Monitor ID'B'-'0'-'A'

Message
STX-'C'-'3'-'1'-'D'ST-EN-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
'0'-'A'(30h, 41h): Message length
Message
STX (02h): Start of Message
'C'-'3'-'1'-'D' (43h, 33h, 31h, 44h): Security Lock Control reply command
ST-EN: Lock condition result data
ST: Status
'0'-'0'(30h, 30h): No error
'0'-'1'(30h, 31h): Error
EN: Enable /Disable (Current condition)
'0'-'0'(30h, 30h): Disable
'0'-'1'(30h, 31h): Enable
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(79/141)

14. Direct TV Chanel Read & Write
When DTV unit (Option unit) is installed, channel settings is read and write directly.

14.1 Direct TV Chanel Read & Reply
1) The controller requests the monitor to read channel information.
Header
Message
Check code
SOH-'0'-Monitor IDSTX-'C'-'2'-'2'-'C'-ETX
BCC
'0'-'A'-'0'-'6'

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID which you want to get Model Name.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'6'(30h, 36h): Message length
Message
STX (02h): Start of Message
'C'-'2'-'2'-'C' (43h, 32h, 32h, 43h): Direct TV Channel Read command
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies the result to the controller.
Header
SOH-'0'-'0'-Monitor ID'B'-'1'-'2'

Message
STX-'C'-'3'-'2'-'C'MajorCH-MinorCH-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
'1'-'2'(31h, 32h): Message length = 18bytes
Message
STX (02h): Start of Message
'C'-'3'-'2'-'C' (43h, 33h, 32h, 43h): Direct TV Channel read reply command
MajorCH: Major Channel (00000000h – FFFFFFFFh),
'0'-'0'-'0'-'0'-'0'-'0'-'0'-'0' - 'F'-'F'-'F'-'F'-'F'-'F'-'F'-'F'
MinorCH: Minor Channel (0000h – FFFFh),
'0'-'0'-'0'-'0' - 'F'-'F'-'F'-'F'
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(80/141)

14.2 Direct TV Chanel Write & Reply
1) The controller requests the monitor to write channel information.
Header
Message
Check code
Delimiter
SOH-'0'-Monitor IDSTX-'C'-'2'-'2'-'D'BCC
CR
'0'-'A'-'1'-'2'
MajorCH-MinorCH-ETX
Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID which you want to get Model Name.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'1'-'2'(31h, 32h): Message length = 18bytes
Message
STX (02h): Start of Message
'C'-'2'-'2'-'D' (43h, 32h, 32h, 44h): Direct TV Channel write command
MajorCH: Major Channel (00000000h – FFFFFFFFh),
'0'-'0'-'0'-'0'-'0'-'0'-'0'-'0' - 'F'-'F'-'F'-'F'-'F'-'F'-'F'-'F'
MinorCH: Minor Channel (0000h – FFFFh),
'0'-'0'-'0'-'0' - 'F'-'F'-'F'-'F'
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies the result to the controller.
Header
SOH-'0'-'0'-Monitor ID'B'-'1'-'2'

Message
STX-'C'-'3'-'2'-'D'MajorCH-MinorCH-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
'1'-'2'(31h, 32h): Message length = 18bytes
Message
STX (02h): Start of Message
'C'-'3'-'2'-'D' (43h, 33h, 32h, 43h): Direct TV Channel write reply command
MajorCH: Major Channel (00000000h – FFFFFFFFh),
'0'-'0'-'0'-'0'-'0'-'0'-'0'-'0' - 'F'-'F'-'F'-'F'-'F'-'F'-'F'-'F'
MinorCH: Minor Channel (0000h – FFFFh),
'0'-'0'-'0'-'0' - 'F'-'F'-'F'-'F'
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(81/141)

15. Daylight Saving read & write
15.1 Daylight Saving Read
This command is used in order to read the setting of Daylight Saving.
1) The controller requests the monitor to reply a Daylight Saving setting.
Header
SOH-'0'-Monitor ID'0'-'A'-'0'-'8'

Message
STX-'C'-'A'-'0'-'1'-'0'-'0'-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'8'(30h, 38h): Message length (8bytes)
Message
STX (02h): Start of Message
'C'-'A'-'0'-'1' (43h, 41h, 30h, 31h): Daylight Saving Command
'0'-'0' (30h. 30h): Read
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies Date & Time to the controller.
Header
SOH-'0'-'0'-Monitor ID'B'-'2'-'0'

Message
STX-'C'-'B'-'0'-'1'-'0'-'0'-ST-BM-BD1-BD
-BT1-BT2-EM-ED1-ED2-ET1-ET2-TD-ETX

Check
code
BCC

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to ‘A’, replying monitor’s ID is ‘1’.
'B' (42h): Message type is "Command reply".
'2'-'0'(32h, 30h): Message length (32bytes)
Message
STX (02h): Start of Message
'C'-'B'-'0'-'1' (43h, 42h, 30h, 31h): Daylight Saving Setting reply command
'0'-'0' (30h, 30h): Read
ST: Error Status
No Error : 00h (30h, 30h)
Error
: 01h (30h, 31h)
BM: BEGIN MONTH
JANUARY – DECEMBER: 01h (30h, 31h) - 12h (31h, 32h)
BD1: BEGIN DAY1
FIRST
: 01h (30h, 31h)
SECOND : 02h (30h, 32h)
THIRD
: 03h (30h, 33h)
FOUR
: 04h (30h, 34h)

(82/141)

Delimiter
CR

LAST
: 05h (30h, 35h)
BD2: BEGIN DAY2 (Day of the week)
SUNDAY
: 01h (30h, 31h)
MONDAY
: 02h (30h, 32h)
TUESDAY
: 03h (30h, 33h)
WEDNESDAY
: 04h (30h, 34h)
THURSDAY
: 05h (30h, 35h)
FRIDAY
: 06h (30h, 36h)
SATURDAY
: 07h (30h, 37h)
BT1: BEGIN TIME1 (Hour)
00h (30h, 30h) – 23 (32h, 33h)
BT2: BEGIN TIME2 (Minute)
00h (30h, 30h) – 59 (35h, 39h)
EM: END MONTH
JANUARY – DECEMBER: 01h (30h, 31h) - 12h (31h, 32h)
ED1: END DAY1
FIRST
: 01h (30h, 31h)
SECOND : 02h (30h, 32h)
THIRD
: 03h (30h, 33h)
FOUR
: 04h (30h, 34h)
LAST
: 05h (30h, 35h)
ED2: END DAY2 (Day of the week)
SUNDAY
: 01h (30h, 31h)
MONDAY
: 02h (30h, 32h)
TUESDAY
: 03h (30h, 33h)
WEDNESDAY
: 04h (30h, 34h)
THURSDAY
: 05h (30h, 35h)
FRIDAY
: 06h (30h, 36h)
SATURDAY
: 07h (30h, 37h)
ET1: END TIME1 (Hour)
00h (30h, 30h) – 23 (32h, 33h)
ET2: END TIME2 (Minute)
00h (30h, 30h) – 59 (35h, 39h)
TD: TIME DIFFERENCE
+01:00 : 00h (30h, 30h)
+00:30 : 01h (30h, 31h)
-00:30 : 02h (30h, 32h)
-01:00 : 03h (30h, 33h)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(83/141)

15.2 Daylight Saving Write
This command is used in order to write the setting of the Daylight Saving.
1) The controller requests the monitor to write Daylight Saving.
Header
SOH-'0'-Monitor ID'0'-'A'-'1'-'E'

Message
STX-'C'-'A'-'0'-'1'-'0'-'1'-BM-BD1-BD2BT1-BT2-EM-ED1-ED2-ET1-ET2-TD-ETX

Check code
BCC

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'1'-'E'(31h, 45h): Message length (30bytes)
Message
STX (02h): Start of Message
'C'-'A'-'0'-'1' (43h, 41h, 30h, 31h): Daylight Saving Setting Command
'0'-'1' (30h, 31h): Write
BM: BEGIN MONTH
JANUARY – DECEMBER: 01h (30h, 31h) - 12h (31h, 32h)
BD1: BEGIN DAY1
FIRST
: 01h (30h, 31h)
SECOND : 02h (30h, 32h)
THIRD
: 03h (30h, 33h)
FOUR
: 04h (30h, 34h)
LAST
: 05h (30h, 35h)
BD2: BEGIN DAY2 (Day of the week)
SUNDAY
: 01h (30h, 31h)
MONDAY
: 02h (30h, 32h)
TUESDAY
: 03h (30h, 33h)
WEDNESDAY
: 04h (30h, 34h)
THURSDAY
: 05h (30h, 35h)
FRIDAY
: 06h (30h, 36h)
SATURDAY
: 07h (30h, 37h)
BT1: BEGIN TIME1 (Hour)
00h (30h, 30h) – 23 (32h, 33h)
BT2: BEGIN TIME2 (Minute)
00h (30h, 30h) – 59 (35h, 39h)
EM: END MONTH
JANUARY – DECEMBER: 01h (30h, 31h) - 12h (31h, 32h)
ED1: END DAY1
FIRST
: 01h (30h, 31h)
SECOND : 02h (30h, 32h)
THIRD
: 03h (30h, 33h)
FOUR
: 04h (30h, 34h)
LAST
: 05h (30h, 35h)
ED2: END DAY2 (Day of the week)
SUNDAY
: 01h (30h, 31h)
MONDAY
: 02h (30h, 32h)
TUESDAY
: 03h (30h, 33h)
WEDNESDAY
: 04h (30h, 34h)
THURSDAY
: 05h (30h, 35h)
FRIDAY
: 06h (30h, 36h)
SATURDAY
: 07h (30h, 37h)
ET1: END TIME1 (Hour)
00h (30h, 30h) – 23 (32h, 33h)
ET2: END TIME2 (Minute)
00h (30h, 30h) – 59 (35h, 39h)
TD: TIME DIFFERENCE

(84/141)

Delimiter
CR

+01:00 :
+00:30 :
-00:30 :
-01:00 :
ETX (03h): End

00h (30h, 30h)
01h (30h, 31h)
02h (30h, 32h)
03h (30h, 33h)
of Message

Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies a written in result.
Header
Message
SOH-'0'-'0'-Monitor IDSTX-'C'-'B'-'0'-'1'-'0'-'1'-ST-ETX
'B'-'0'-'A'

Check code
BCC

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to ‘A’, replying monitor’s ID is ‘1’.
'B' (42h): Message type is "Command reply".
'0'-'A'(30h, 41h): Message length (10bytes)
Message
STX (02h): Start of Message
'C'-'B'-'0'-'1' (43h, 42h, 30h, 31h): Daylight Saving Setting Command
'0'-'1' (30h, 31h): Write
ST: Error Status
No Error : 00h (30h, 30h)
Error
: 01h (30h, 31h)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(85/141)

Delimiter
CR

16. Firmware Version
16.1 Firmware Version Read
This command is used in order to read a firmware version.
1) The controller requests the monitor to reply a firmware version.
Header
SOH-'0'-Monitor ID'0'-'A'-'0'-'8'

Message
STX-'C'-'A'-'0'-'2'-TY-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'8'(30h, 38h): Message length (8bytes)
Message
STX (02h): Start of Message
'C'-'A'-'0'-'2' (43h, 41h, 30h, 32h): Firmware Version Command
TY: Firmware Type
Firmware1 : 00h (30h, 30h)
Firmware2 : 01h (30h, 31h)
Firmware3 : 02h (30h, 32h)
Firmware4 : 03h (30h, 33h)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies a firmware version to the controller.
Header
SOH-'0'-Monitor ID'0'-'B'-'1'-'1'

Message
STX-'C'-B'-'0'-'2'-ST-TY-MVPP-BV1-BV2-BV3-BR1-BR2-ETX

Check code
BCC

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to ‘A’, replying monitor’s ID is ‘1’.
'B' (42h): Message type is "Command reply".
'1'-'1'(31h, 31h): Message length (17bytes)
Message
STX (02h): Start of Message
'C'-'B'-'0'-'2' (43h, 42h, 30h, 32h): Firmware Version Read reply
ST: Error Status
No Error : 00h (30h, 30h)
Error
: 01h (30h, 31h)
TY: Firmware Type
Firmware1 : 00h (30h, 30h)
Firmware2 : 01h (30h, 31h)
MV: Major Version:

(86/141)

Delimiter
CR

00h (30h, 30h) – 09h (30h, 39h)
PP: Period:
2Eh (32h, 45h) (fixed)
BV1: Minor (Basic) Version1:
00h (30h, 30h) – 09h (30h, 39h)
BV2: Minor (Basic) Version2:
00h (30h, 30h) – 09h (30h, 39h)
BV3: Minor (Basic) Version3:
00h (30h, 30h) – 09h (30h, 39h)
BR1: Branch Version1:
A:41h (34h, 31h) – Z:5Ah (35h, 41h)
BR2: Branch Version1:
A:41h (34h, 31h) – Z:5Ah (35h, 41h)
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(87/141)

17. Auto ID
17.1 Auto ID Execute
This command is used in order to execute Auto ID function.
1) The controller requests the monitor to execute Auto ID function.
Header
SOH-'0'-Monitor ID'0'-'A'-'0'-'8'

Message
STX-'C'-'A'-'0'-'A'-'0'-'1'-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'8'(30h, 38h): Message length (8byte)
Message
STX (02h): Start of Message
'C'-'A'-'0'-'A' (43h, 41h, 30h, 41h, 30h, 31h): Auto ID Command
'0'-'1' (30h, 30h): Execute
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies receipt result.
Header
SOH-'0'-'0'-Monitor ID'B'-'0'-'A'

Message
STX-'C'-'B'-'0'-'A'-'0'-'1'-ST-ETX

Check code
BCC

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to ‘A’, replying monitor’s ID is ‘1’.
'B' (42h): Message type is "Command reply".
'0'-'A'(30h,41h): Message length (10byte)
Message
STX (02h): Start of Message
'C'-'B'-'0'-'A' (43h, 42h, 30h, 41h, 30h, 31h): Auto ID Reply Command
'0'-'1' (30h, 30h): Execute
ST: Error Status
No Error : 00h (30h, 30h)
Error
: 01h (30h, 31h)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.

(88/141)

Delimiter
CR

Delimiter
CR (0Dh): End of packet

(89/141)

17.2 Auto ID Complete
This command is used in order to notify complete status of Auto ID.
1) The monitor sends the controller to complete status of Auto ID.
Header
SOH-'0'-Monitor ID'0'-'A'-'0'-'C'

Message
STX-'C'-'A'-'0'-'A'-'0'-'2'-ST-MON-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'C'(30h,43h): Message length (12byte)
Message
STX (02h): Start of Message
'C'-'A'-'0'-'A'-'0'-'2' (43h, 41h, 30h, 41h, 30h, 32h): Auto ID
'0'-'2' (30h,32h): Complete
ST: Error Status
No Error : 00h (30h, 30h)
Error
: 01h (30h, 31h)
MON: DETECTED MONITORS
01h (30h, 31h) - 64h (36h, 34h)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The controller replies to the monitor.
Header
SOH-'0'-'0'-Monitor ID'B'-'0'-'A'

Message
STX-'C'-'B'-'0'-'A'-'0'-'2'-ST-ETX

Check code
BCC

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to ‘A’, replying monitor’s ID is ‘1’.
'B' (42h): Message type is "Command reply".
'0'-'A'(30h,41h): Message length (10byte)
Message
STX (02h): Start of Message
'C'-'B'-'0'-'A' (43h, 42h, 30h, 41h): Auto ID Reply Command
'0'-'2' (30h,32h): Complete
ST : Error Status
No Error : 00h (30h, 30h) *Fixed
ETX (03h): End of Message

(90/141)

Delimiter
CR

Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(91/141)

17.3 Auto ID Reset
This command is used in order to reset Auto ID.
1) The controller requests the monitor to reset Auto ID.
Header
SOH-'0'-Monitor ID'0'-'A'-'0'-'8'

Message
STX-'C'-'A'-'0'-'A'-'0'-'3'-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'8'(30h, 38h): Message length (8byte)
Message
STX (02h): Start of Message
'C'-'A'-'0'-'A' (43h, 41h, 30h, 41h): Auto ID Command
'0'-'3' (30h, 33h): Reset
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies to the controller.
Header
SOH-'0'-'0'-Monitor ID'B'-'0'-'A'

Message
STX-'C'-'B'-'0'-'A'-'0'-'3'-ST-ETX

Check code
BCC

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to ‘A’, replying monitor’s ID is ‘1’.
'B' (42h): Message type is "Command reply".
'0'-'A'(30h,41h): Message length (10byte)
Message
STX (02h): Start of Message
'C'-'B'-'0'-'A' (43h, 42h, 30h, 41h): Auto ID Reply
'0'-'3' (30h, 33h): Reset
ST: Error Status
No Error : 00h (30h, 30h)
Error
: 01h (30h, 31h)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(92/141)

Delimiter
CR

18. Input Name
18.1 Input Name Read
This command is used in order to read the setting of Input Name.
1) The controller requests the monitor to reply Input Name setting.
Header
SOH-'0'-Monitor ID'0'-'A'-'0'-'8'

Message
STX-'C'-'A'-'0'-'4'-'0'-'0'-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'8'(30h, 38h): Message length (8bytes)
Message
STX (02h): Start of Message
'C'-'A'-'0'-'4' (43h, 41h, 30h, 34h): Input Name Command
'0'-'0' (30h. 30h): Read
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies Input Name to the controller.
Header
SOH-'0'-'0'-Monitor ID'B'-LN(H)-LN(L)

Message
STX-'C'-'B'-'0'-'4'-'0'-'0'Data(0)-Data(1)-Data(2)- --- -Data(n)-ETX

Check
code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to ‘A’, replying monitor’s ID is ‘1’.
'B' (42h): Message type is "Command reply".
LN(H)-LN(L): Message length (byte length), from STX to ETX
Ex.) The byte data 20h is encoded as ASCII characters '2' and '0' (32h and 30h).
Message
STX (02h): Start of Message
'C'-'B'-'0'-'4' (43h, 42h, 30h, 34h): Input Name command reply
'0'-'0' (30h, 30h): Read
Data(n) : Input name *n = Max 14
Ø
The byte data 20h is encoded as ASCII characters '2' and '0' (32h and 30h).
Ex.) For example when receiving Data(n) of 35h 36h 34h 37h 34h 31h
Step1: Input Name data is encoded as character code.
Example:
35h 36h 34h 37h 34h 31h -> '5'-'6'-'4'-'7'-'4'-'1'
Step2: Decode pairs of ASCII characters to hexadecimal values.
Example:
'5'-'6'-'4'-'7'-'4'-'1' -> 56h 47h 41h
Step3: Byte data represents the ASCII string data.
(93/141)

Example:
56h 47h 41h -> “VGA”
Result: Input Name is “VGA”.
Note: No null termination character is sent.
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.

Delimiter
CR (0Dh): End of packet

(94/141)

18.2 Input Name Write
This command is used in order to write the setting of Input Name.
1) The controller requests the monitor to write Input Name.
Header
SOH-'0'-Monitor ID'0'-'A'- LN(H)-LN(L)

Message
STX-'C'-'A'-'0'-'4'-'0'-1'Data(0)-Data(1)-Data(2)- --- -Data(n)-ETX

Check
code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
LN(H)-LN(L): Message length (byte length), from STX to ETX
Ex.) The byte data 20h is encoded as ASCII characters '2' and '0' (32h and 30h).
Message
STX (02h): Start of Message
'C'-'A'-'0'-'4' (43h, 41h, 30h, 34h): Input name Command
'0'-'1' (30h, 31h): Write
Data(n) : Input name *n = Max 14
Ø
The byte data 20h is encoded as ASCII characters '2' and '0' (32h and 30h).
Ex.) In the case of Input Name "VGA"
Step1: Input Name data is handled as character code.
Example:
"VGA" -> 56h 47h 41h (ASCII)
Step2: The hexadecimal value of each original character is encoded as two ASCII
characters representing the value.
Example:
56h 47h 41h -> '5'-'6'-'4'-'7'-'4'-'1'
Result: The following data is assigned to Data(n).
35h 36h 34h 37h 34h 31h
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies a written in result.
Header
Message
SOH-'0'-'0'-Monitor IDSTX-'C'-'B'-'0'-'0'-'0'-'1'-ST-ETX
'B'-'0'-'A'

Check code
BCC

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to ‘A’, replying monitor’s ID is ‘1’.
'B' (42h): Message type is "Command reply".
'0'-'A'(30h, 41h): Message length (10bytes)
Message
STX (02h): Start of Message
'C'-'B'-'0'-'4' (43h, 42h, 30h, 34h): Input name Command
'0'-'1' (30h, 31h): Write

(95/141)

Delimiter
CR

ST: Status
00h (30h, 30h): No Error
01h (30h, 31h): Error
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(96/141)

18.3 Input Name Reset
This command is used in order to reset the Input Name.
1) The controller requests the monitor to reset Input Name.
Header
SOH-'0'-Monitor ID'0'-'A'-'0'-'8'

Message
STX-'C'-'A'-'0'-'4'-'0'-'2'-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'8'(30h, 38h): Message length (8bytes)
Message
STX (02h): Start of Message
'C'-'A'-'0'-'4' (43h, 41h, 30h, 34h): Input Name Command
'0'-'2' (30h. 32h): Reset
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies result.
Header
Message
SOH-'0'-'0'-Monitor IDSTX-'C'-'B'-'0'-'0'-'0'-'2'-ST-ETX
'B'-'0'-'A'

Check code
BCC

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to ‘A’, replying monitor’s ID is ‘1’.
'B' (42h): Message type is "Command reply".
'0'-'A'(30h, 41h): Message length (10bytes)
Message
STX (02h): Start of Message
'C'-'B'-'0'-'4' (43h, 42h, 30h, 34h): Input name Command
'0'-'2' (30h, 32h): Reset
ST: Status
00h (30h, 30h): No Error
01h (30h, 31h): Error
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.

(97/141)

Delimiter
CR

Delimiter
CR (0Dh): End of packet

(98/141)

19. Auto Tile Matrix
19.1 Auto Tile Matrix Execute
This command is used in order to activate the Auto Tile Matrix Setup.
1) The controller requests the monitor to execute Auto Tile Matrix
Header
SOH-'0'-Monitor ID'0'-'A'-'1'-'2'

Message
STX-'C'-'A'-'0'-'3'-'0'-'1'HM-VM-PID-SEL-TMEM-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'1'-'2'(31h, 32h): Message length (18bytes)
Message
STX (02h): Start of Message
'C'-'A'-'0'-'3' (43h, 41h, 30h, 33h): Auto Tile Matrix Command
'0'-'1' (30h, 31h): Execution
HM: HORIZONTAL MONITORS
01h (30h, 31h) - 10h (31h, 30h)
VM: VERTICAL MONITORS
01h (30h, 31h) - 10h (31h, 30h)
PID: PETTERN ID
01h (30h, 31h) *Fixed
SEL: CURRENT INPUT SELECT
VGA
: 01h (30h, 31h)
DVI
: 03h (30h, 33h)
VIDEO
: 05h (30h, 35h)
S-VIDEO : 07h (30h, 37h)
Y/Pb/Pr : 0Ch (30h, 43h)
OPTION : 0Dh (30h, 44h)
Y/Pb/Pr2 : 0Eh (30h, 45h)
DPORT
: 0Fh (30h, 46h)
DPORT2 : 10h (31h, 30h)
HDMI
: 11h (31h, 31h)
HDMI2
: 12h (31h, 32h)
DPORT3 : 80h (38h, 30h)
TMEM: TILE MATRIX MEM
COMMON : 00h (30h, 30h)
INPUT
: 01h (30h, 31h)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies receipt result.
Header
SOH-'0'-'0'-Monitor ID'B'-'0'-'A'

Message
STX-'C'-'B'-'0'-'3'-'0'-'1'-ST-ETX

Header
SOH (01h): Start of Header
'0' (30h): Reserved
(99/141)

Check code
BCC

Delimiter
CR

'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to ‘A’, replying monitor’s ID is ‘1’.
'B' (42h): Message type is "Command reply".
'0'-'A'(30h, 41h): Message length (10bytes)
Message
STX (02h): Start of Message
'C'-'B'-'0'-'3' (43h, 42h, 30h, 33h): Auto Tile Matrix Command
'0'-'1' (30h, 31h): Execution
ST: Error Status
No Error : 00h (30h, 30h)
Error
: 01h (30h, 31h)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(100/141)

19.2 Auto Tile Matrix Complete
This command is used in order to notify complete status of Auto Tile Matrix Setup.
1) The monitor notifies that Auto Tile Matrix completed to controller.
Header
SOH-'0'-Monitor ID'0'-'A'-'0'-'A'

Message
STX-'C'-'A'-'0'-'3'-'0'-'2'-ST-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'A'(30h, 41h): Message length (10bytes)
Message
STX (02h): Start of Message
'C'-'A'-'0'-'3'-'0'-'2' (43h, 41h, 30h, 33h, 30h, 32h): Auto Tile Matrix Complete
'0'-'2' (30h, 32h): Notify
ST: Error Status
No Error : 00h (30h, 30h)
Error
: 01h (30h, 31h)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The controller replies to the monitor.
Header
SOH-'0'-'0'-Monitor ID'B'-'0'-'A'

Message
STX-'C'-'B'-'0'-'3'-'0'-'2'-ST-ETX

Check code
BCC

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to ‘A’, replying monitor’s ID is ‘1’.
'B' (42h): Message type is "Command reply".
'0'-'A'(30h, 41h): Message length (10bytes)
Message
STX (02h): Start of Message
'C'-'B'-'0'-'3' (43h, 42h, 30h, 33h): Auto Tile Matrix Command
'0'-'2' (30h, 32h): Notify
ST: Error Status
No Error : 00h (30h, 30h) *Fixed
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.

(101/141)

Delimiter
CR

Delimiter
CR (0Dh): End of packet

(102/141)

19.3 Auto Tile Matrix Monitors Read
This command is used in order to read the setting of H/V Monitors.
1) The controller requests the monitor to reply H/V Monitors setting.
Header
SOH-'0'-Monitor ID'0'-'A'-'0'-'8'

Message
STX-'C'-'A'-'0'-'3'-'0'-'4'-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'8'(30h, 38h): Message length (8bytes)
Message
STX (02h): Start of Message
'C'-'A'-'0'-'3' (43h, 41h, 30h, 33h): Auto Tile Matrix Command
'0'-'4' (30h. 34h): Monitors Read
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies H/V Monitors to the controller.
Header
SOH-'0'-'0'-Monitor ID'B'-'0'-'E'

Message
STX-'C'-'B'-'0'-'3'-'0'-'4'ST-HM-VM-ETX

Check code
BCC

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to ‘A’, replying monitor’s ID is ‘1’.
'B' (42h): Message type is "Command reply".
'0'-'E'(30h, 45h): Message length (14bytes)
Message
STX (02h): Start of Message
'C'-'B'-'0'-'3' (43h, 42h, 30h, 33h): Auto Tile Matrix reply
'0'-'4' (30h, 34h): Monitors Read
ST: Error Status
No Error : 00h (30h, 30h)
Error
: 01h (30h, 31h)
HM: H MONITORS
00h – 0Ah (30h, 30h – 30h, 41h)
VM: V MONITORS
00h – 0Ah (30h, 30h – 30h, 41h)
ETX (03h): End of Message
Check code
BCC: Block Check Code
(103/141)

Delimiter
CR

Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(104/141)

19.4 Auto Tile Matrix Monitors Write
This command is used in order to write the setting of H/V Monitors.
1) The controller requests the monitor to write H/V Monitors.
Header
SOH-'0'-Monitor ID'0'-'A'-'0'-'C'

Message
STX-'C'-'A'-'0'-'3'-'0'-'5'-HM-VM-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'C'(30h, 43h): Message length (12bytes)
Message
STX (02h): Start of Message
'C'-'A'-'0'-'3' (43h, 41h, 30h, 33h): Auto Tile Matrix Command
'0'-'5' (30h. 34h): Monitors Write
HM: H MONITORS
00h – 0Ah (30h, 30h – 30h, 41h)
VM: V MONITORS
00h – 0Ah (30h, 30h – 30h, 41h)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies a written in result.
Header
Message
SOH-'0'-'0'-Monitor IDSTX-'C'-'B'-'0'-'3'-'0'-'5'-ST-ETX
'B'-'0'-'A'

Check code
BCC

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to ‘A’, replying monitor’s ID is ‘1’.
'B' (42h): Message type is "Command reply".
'0'-'A'(30h, 41h): Message length (14bytes)
Message
STX (02h): Start of Message
'C'-'B'-'0'-'3' (43h, 42h, 30h, 33h): Auto Tile Matrix reply
'0'-'5' (30h, 34h): Monitors Write
ST: Error Status
No Error : 00h (30h, 30h)
Error
: 01h (30h, 31h)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
(105/141)

Delimiter
CR

Delimiter
CR (0Dh): End of packet

(106/141)

19.5 Auto Tile Matrix Reset
This command is used in order to deactivate the Auto Tile Matrix Setup.
1) The controller requests the monitor to reset Auto Tile Matrix
Header
SOH-'0'-Monitor ID'0'-'A'-'0'-'8'

Message
STX-'C'-'A'-'0'-'3'-'0'-'6'-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'8'(30h, 38h): Message length (8bytes)
Message
STX (02h): Start of Message
'C'-'A'-'0'-'3' (43h, 41h, 30h, 33h, 30h, 33h): Auto Tile Matrix
'0'-'6' (30h, 36h): Off
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies receipt result.
Header
SOH-'0'-'0'-Monitor ID'B'-'0'-'A'

Message
STX-'C'-'B'-'0'-'3'-'0'-'6'-ST-ETX

Check code
BCC

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to ‘A’, replying monitor’s ID is ‘1’.
'B' (42h): Message type is "Command reply".
'0'-'A'(30h, 41h): Message length (10bytes)
Message
STX (02h): Start of Message
'C'-'B'-'0'-'3' (43h, 42h, 30h, 33h) : Auto Tile Matrix
'0'-'6' (30h, 36h): Off
ST: Error Status
No Error : 00h (30h, 30h)
Error
: 01h (30h, 31h)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.

(107/141)

Delimiter
CR

Delimiter
CR (0Dh): End of packet

(108/141)

20. Power Save Mode
20.1 Power Save Mode Read
This command is used in order to read the Power Save Mode.
1) The controller requests the monitor to read Power Save Mode
Header
SOH-'0'-Monitor ID'0'-'A'-'0'-'8'

Message
STX-'C'-'A'-'0'-'B'-0'-'0'-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'8'(30h,38h): Message length (8byte)
Message
STX (02h): Start of Message
'C'-'A'-'0'-'B' (43h, 41h, 30h, 42h): Power Save Mode command
'0'-'0' (30h, 30h): Read
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies Power Save Mode to the controller.
Header
SOH-'0'-'0'-Monitor ID'B'-'0'-'A'

Message
STX-'C'-'B'-'0'-'B'-'0'-'0'-MODE-ETX

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to ‘A’, replying monitor’s ID is ‘1’.
'B' (42h): Message type is "Command reply".
'0'-'A'(30h,41h): Message length (10byte)
Message
STX (02h): Start of Message
'C'-'B'-'0'-'B' (43h, 42h, 30h, 42h): Power Save Mode Reply
'0'-'0' (30h, 30h): Read
MODE: POWER SAVE MODE
00h (30h, 30h): AUTO POWER SAVE
01h (30h, 31h): AUTO STANDBY
02h (30h, 32h): POWER SAVE OFF
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.

(109/141)

Check code
BCC

Delimiter
CR

Delimiter
CR (0Dh): End of packet

(110/141)

20.2 Power Save Mode Write
This command is used in order to write the setting of Power Save Mode.
1) The controller requests the monitor to write Power Save Mode.
Header
SOH-'0'-Monitor ID'0'-'A'-'0'-'A'

Message
STX-'C'-'A'-'0'-'B'-0'-'1'-MODE-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'A'(30h, 41h): Message length (10byte)
Message
STX (02h): Start of Message
'C'-'A'-'0'-'B' (43h, 41h, 30h, 42h): Power Save Mode command
'0'-'1' (30h, 31h): Write
MODE: POWER SAVE MODE
00h (30h, 30h): AUTO POWER SAVE
01h (30h, 31h): AUTO STANDBY
02h (30h, 32h): POWER SAVE OFF
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies a written in result.
Header
Message
SOH-'0'-'0'-Monitor IDSTX-'C'-'B'-'0'-'B'-'0'-'1'-ST-ETX
'B'-'0'-'A'

Check code
BCC

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to ‘A’, replying monitor’s ID is ‘1’.
'B' (42h): Message type is "Command reply".
'0'-'A'(30h,41h): Message length (10byte)
Message
STX (02h): Start of Message
'C'-'B'-'0'-'B' (43h, 42h, 30h, 42h): Power Save Mode Reply
'0'-'1' (30h, 31h): Write
ST: Error Status
No Error : 00h (30h, 30h)
Error
: 01h (30h, 31h)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
(111/141)

Delimiter
CR

Delimiter
CR (0Dh): End of packet

(112/141)

20.3 Auto Power Save Time Read
This command is used in order to read the setting of Auto Power Save Time.
1) The controller requests the monitor to reply Time setting.
Header
SOH-'0'-Monitor ID'0'-'A'-'0'-'8'

Message
STX-'C'-'A'-'0'-'B'-'0'-'2'-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'8'(30h,38h): Message length (8byte)
Message
STX (02h): Start of Message
'C'-'A'-'0'-'B' (43h, 41h, 30h, 42h): Power Save Mode command
'0'-'2' (30h, 30h): Auto Power Save Read
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies Time to the controller.
Header
SOH-'0'-'0'-Monitor ID'B'-'0'-'A'

Message
STX-'C'-'B'-'0'-'B'-'0'-'2'-TIME-ETX

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to ‘A’, replying monitor’s ID is ‘1’.
'B' (42h): Message type is "Command reply".
'0'-'A'(30h,41h): Message length (10byte)
Message
STX (02h): Start of Message
'C'-'B'-'0'-'B' (43h, 42h, 30h, 42h): Power Save Mode Reply
'0'-'2' (30h, 32h): Auto Power Save Time Read
TIME: AUTO POWER SAVE TIME (sec.)
00h (30h, 30h) – 78h (37h, 38h): 1 (5dec.) – 120 (600sec.)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(113/141)

Check code
BCC

Delimiter
CR

20.4 Auto Power Save Time Write
This command is used in order to write the setting of Auto Power Save Time.
1) The controller requests the monitor to write Time.
Header
SOH-'0'-Monitor ID'0'-'A'-'0'-'A'

Message
STX-'C'-'A'-'0'-'B'-0'-'3'-TIME-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'A'(30h,41h): Message length (10byte)
Message
STX (02h): Start of Message
'C'-'A'-'0'-'B' (43h, 41h, 30h, 42h): Power Save Mode command
'0'-'3' (30h, 33h): Auto Power Save Time Write
TIME: AUTO POWER SAVE TIME (sec.)
00h (30h, 30h) – 78h (37h, 38h): 1 (5dec.) – 120 (600sec.)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies a written in result.
Header
Message
SOH-'0'-'0'-Monitor IDSTX-'C'-'B'-'0'-'B'-'0'-'3'-ST-ETX
'B'-'0'-'8'

Check code
BCC

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to ‘A’, replying monitor’s ID is ‘1’.
'B' (42h): Message type is "Command reply".
'0'-'8'(30h,38h): Message length (8byte)
Message
STX (02h): Start of Message
'C'-'B'-'0'-'B' (43h, 42h, 30h, 42h): Power Save Mode Reply
'0'-'3' (30h, 33h): Auto Power Save Time Write
ST: Error Status
No Error : 00h (30h, 30h)
Error
: 01h (30h, 31h)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.

(114/141)

Delimiter
CR

Delimiter
CR (0Dh): End of packet

(115/141)

20.5 Auto Standby Time Read
This command is used in order to read the setting of Auto Standby Time.
1) The controller requests the monitor to reply Time setting.
Header
SOH-'0'-Monitor ID'0'-'A'-'0'-'8'

Message
STX-'C'-'A'-'0'-'B'-'0'-'4'-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'8'(30h,38h): Message length (8byte)
Message
STX (02h): Start of Message
'C'-'A'-'0'-'B' (43h, 41h, 30h, 42h): Power Save Mode command
'0'-'4' (30h, 30h): Auto Standby Time Read
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies Time to the controller.
Header
SOH-'0'-'0'-Monitor ID'B'-'0'-'A'

Message
STX-'C'-'B'-'0'-'B'-'0'-'4'-TIME-ETX

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to ‘A’, replying monitor’s ID is ‘1’.
'B' (42h): Message type is "Command reply".
'0'-'A'(30h,41h): Message length (10byte)
Message
STX (02h): Start of Message
'C'-'B'-'0'-'B' (43h, 42h, 30h, 42h): Power Save Mode Reply
'0'-'4' (30h, 34h): Auto Standby Time Read
TIME: AUTO STANDBY TIME (sec.)
00h (30h, 30h) – 78h (37h, 38h): 1 (5dec.) – 120 (600sec.)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(116/141)

Check code
BCC

Delimiter
CR

20.6 Auto Standby Time Write
This command is used in order to write the setting of Auto Standby Time.
1) The controller requests the monitor to write Time.
Header
SOH-'0'-Monitor ID-'0''A'-'0'-'A'

Message
STX-'C'-'A'-'0'-'B'-0'-'5'-TIME-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'A'(30h,41h): Message length (10byte)
Message
STX (02h): Start of Message
'C'-'A'-'0'-'B' (43h, 41h, 30h, 42h): Power Save Mode command
'0'-'5' (30h, 35h): Auto Standby Time Write
TIME: AUTO STANDBY TIME (sec.)
00h (30h, 30h) – 78h (37h, 38h): 1 (5dec.) – 120 (600sec.)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies a written in result.
Header
Message
SOH-'0'-'0'-Monitor IDSTX-'C'-'B'-'0'-'B'-'0'-'5'-ST-ETX
'B'-'0'-'A'

Check code
BCC

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to ‘A’, replying monitor’s ID is ‘1’.
'B' (42h): Message type is "Command reply".
'0'-'A'(30h,41h): Message length (10byte)
Message
STX (02h): Start of Message
'C'-'B'-'0'-'B' (43h, 42h, 30h, 42h): Power Save Mode Reply
'0'-'5' (30h, 35h): Auto Standby Time Write
ST: Error Status
No Error : 00h (30h, 30h)
Error
: 01h (30h, 31h)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.

(117/141)

Delimiter
CR

Delimiter
CR (0Dh): End of packet

(118/141)

21. Setting Copy
21.1 Setting Copy Read
This command is used in order to read the Setting Copy.
1) The controller requests the monitor to read Setting Copy
Header
SOH-'0'-Monitor ID'0'-'A'-'0'-'8'

Message
STX-'C'-'A'-'0'-'9'-0'-'0'-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'8'(30h, 38h): Message length (8byte)
Message
STX (02h): Start of Message
'C'-'A'-'0'-'9' (43h,41h,30h,39h): Setting Copy command
'0'-'0' (30h,30h): Target Read
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies Setting Copy to the controller.
Header
SOH-'0'-'0'-Monitor ID'B'-'1'-'0'

Message
STX-'C'-'B'-'0'-'9'-'0'-'0'T4-T3-T2-T1-ETX

Check code
BCC

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to ‘A’, replying monitor’s ID is ‘1’.
'B' (42h): Message type is "Command reply".
'1'-'0'(31h,30h): Message length (16byte)
Message
STX (02h): Start of Message
'C'-'B'-'0'-'9' (43h, 42h, 30h, 39h): Setting Copy Reply
'0'-'0' (30h, 30h): Target Read
T1 – T4 : 00h (30h, 30h) – FFh (46h, 46h)
T1 : Setting Copy Target 4 (Bit12-Bit15)
T2 : Setting Copy Target 3 (Bit8-Bit11)
T3 : Setting Copy Target 2 (Bit4-Bit7)
T4 : Setting Copy Target 1 (Bit0-Bit3)
Bit0: ALL INPUT
Bit1: PICTURE
Bit2: ADJUST
Bit3: AUDIO
Bit4: SCHEDULE
Bit5: PIP

(119/141)

Delimiter
CR

Bit6: OSD
Bit7: MULTI DISP
Bit8: PROTECT
Bit9: EXT-CTRL
Bit10: ADVANCED
Bit11: ADVANCED2
Bit12: HTTP
Bit13: Reserve
Bit14: Reserve
Bit15: Reserve
Ex.) Setting the following value for T4
Bit0: ALL INPUT is OFF (0).
Bit1: PICTURE is OFF (0).
Bit2: ADJUST is ON (1).
Bit3: AUDIO is ON (1).
Step 1: Put above bit in following order.
Bit3-Bit2-Bit1-Bit0
Value: 1100
Step 2: Write the value of Step 1 by a hexadecimal number.
Value: 0Ch
Step 3: Encode the value of Step 2 to ASCII characters.
Value: '0' and 'C' (30h and 43h)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(120/141)

21.2 Setting Copy Write
This command is used in order to write the setting of Setting Copy.
1) The controller requests the monitor to write Setting Copy.
Header
SOH-'0'-Monitor ID'0'-'A'-'1'-'0'

Message
STX-'C'-'A'-'0'-'9'-0'-'1'T4-T3-T2-T1-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'1'-'0'(31h,30h): Message length
Message
STX (02h): Start of Message
'C'-'A'-'0'-'9' (43h,41h,30h,39h): Setting Copy command
'0'-'1' (30h,31h): Target Write
T1 – T4 : 00h (30h, 30h) – FFh (46h, 46h)
T1 : Setting Copy Target 4 (Bit12-Bit15)
T2 : Setting Copy Target 3 (Bit8-Bit11)
T3 : Setting Copy Target 2 (Bit4-Bit7)
T4 : Setting Copy Target 1 (Bit0-Bit3)
Bit0: ALL INPUT
Bit1: PICTURE
Bit2: ADJUST
Bit3: AUDIO
Bit4: SCHEDULE
Bit5: PIP
Bit6: OSD
Bit7: MULTI DISP
Bit8: PROTECT
Bit9: EXT-CTRL
Bit10: ADVANCED
Bit11: ADVANCED2
Bit12: HTTP
Bit13: Reserve
Bit14: Reserve
Bit15: Reserve
Ex.) Setting the following value for T4
Bit0: ALL INPUT is OFF (0).
Bit1: PICTURE is OFF (0).
Bit2: ADJUST is ON (1).
Bit3: AUDIO is ON (1).
Step 1: Put above bit in following order.
Bit3-Bit2-Bit1-Bit0
Value: 1100
Step 2: Write the value of Step 1 by a hexadecimal number.
Value: 0Ch
Step 3: Encode the value of Step 2 to ASCII characters.
Value: '0' and 'C' (30h and 43h)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(121/141)

2) The monitor replies a written in result.
Header
Message
SOH-'0'-'0'-Monitor IDSTX-'C'-'B'-'0'-'9'-'0'-'1'-ST-ETX
'B'-'0'-'A'

Check code
BCC

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to ‘A’, replying monitor’s ID is ‘1’.
'B' (42h): Message type is "Command reply".
'0'-'A'(30h,41h): Message length (10byte)
Message
STX (02h): Start of Message
'C'-'B'-'0'-'9' (43h, 42h, 30h, 39h): Setting Copy Reply
'0'-'1' (30h, 30h): Target Write
ST: Status
No Error
: 00h (30h, 30h)
Error
: 01h (30h, 31h)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(122/141)

Delimiter
CR

21.3 Setting Copy Start
This command is used in order to start Setting Copy.
1) The controller requests the monitor to write Setting Copy Start.
Header
SOH-'0'-Monitor ID'0'-'A'-'0'-'8'

Message
STX-'C'-'A'-'0'-'9'-0'-'2'-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'8'(30h, 38h): Message length (8byte)
Message
STX (02h): Start of Message
'C'-'A'-'0'-'9' (43h,41h,30h,39h): Setting Copy command
'0'-'2' (30h,32h): Start
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies to the controller.
Header
SOH-'0'-'0'-Monitor ID'B'-'0'-'A'

Message
STX-'C'-'B'-'0'-'9'-'0'-'2'-ST-ETX

Check code
BCC

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to ‘A’, replying monitor’s ID is ‘1’.
'B' (42h): Message type is "Command reply".
'0'-'A'(30h,41h): Message length (10byte)
Message
STX (02h): Start of Message
'C'-'B'-'0'-'9' (43h, 42h, 30h, 39h): Setting Copy Reply
'0'-'2' (30h, 30h): Start
ST: Status
No Error : 00h (30h, 30h)
Error
: 01h (30h, 31h)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.

(123/141)

Delimiter
CR

Delimiter
CR (0Dh): End of packet

(124/141)

22. Security Enable
22.1 Security Enable Read
This command is used in order to read the Security Enable.
1) The controller requests the monitor to read Security Enable
Header
SOH-'0'-Monitor ID'0'-'A'-'0'-'8'

Message
STX-'C'-'A'-'0'-'C'-'0'-'2'-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'8'(30h, 38h): Message length (8byte)
Message
STX (02h): Start of Message
'C'-'A'-'0'-'C' (43h, 41h, 30h, 43h): Security password Command
'0'-'2' (30h, 32h): Enable Read
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies Security Enable to the controller.
Header
SOH-'0'-'0'-Monitor ID'B'-'0'-'A'

Message
STX-'C'-'B'-'0'-'C'-'0'-'2'-EN-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to ‘A’, replying monitor’s ID is ‘1’.
'B' (42h): Message type is "Command reply".
'0'-'A'(30h,41h): Message length (10byte)
Message
STX (02h): Start of Message
'C'-'B'-'0'-'C'-'0'-'2' (43h, 42h, 30h, 41h, 30h, 32h): Get Security Enable Disable Reply
EN: Status
00h: Disable
01h: Enable
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.

(125/141)

Delimiter
CR (0Dh): End of packet

(126/141)

22.2 Security Enable Write
This command is used in order to write the setting of Security Enable.
1) The controller requests the monitor to set Security password.
Header
SOH-'0'-Monitor ID'0'-'A'-'1'-'C'

Message
STX-'C'-'A'-'0'-'C'-'0'-'1'ENA-'0'-'0'-PWD1-…-PWD16-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'1'-'C'(31h,43h): Message length (28byte)
Message
STX (02h): Start of Message
'C'-'A'-'0'-'C' (43h, 41h, 30h, 43h): Security Password Command
'0'-'1' (30h, 31h): Enable Write
ENA: Enable/Disable
00h (30h, 30h): Disable
01h (30h, 31h): Enable
'0'-'0' (30h, 30h): Reserved
PWD1 – PWD16: Password data
Ø
The password data is encoded as the following procedure.
Ex.) In the case of password data "1234"
Step1: Password data is handled as character code.
Example:
"1234" -> 31h 32h 33h 34h (ASCII)
Step2: The hexadecimal value of each original character is encoded as two ASCII
characters representing the hex value.
Example:
31h 32h 33h 34h -> '3'-'1'-'3'-'2'-'3'-'3'-'3'-'4'
Step3: Password data is handled as character code once again.
Example:
'3'-'1'-'3'-'2'-'3'-'3'-'3'-'4' -> 33h 31h 33h 32h 33h 33h 33h 34h (ASCII)
Step4: The hexadecimal value of each original character is encoded as two ASCII
characters representing the value.
Example:
33h 31h 33h 32h 33h 33h 33h 34h
-> '3'-'3'-'3'-'1'-'3'-'3'-'3'-'2'-'3'-'3'-'3'-'3'-'3'-'3'-'3'-'4'
Result: The following data is assigned to PWD1-PWD16.
33h 33h 33h 31h 33h 33h 33h 32h 33h 33h 33h 33h 33h 33h 33h 34h
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies a written in result.
Header
Message
SOH-'0'-'0'-Monitor IDSTX-'C'-'B'-'0'-'C'-'0'-'1'-ST-ETX
'B'-'0'-'A'

Header

(127/141)

Check code
BCC

Delimiter
CR

SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to ‘A’, replying monitor’s ID is ‘1’.
'B' (42h): Message type is "Command reply".
'0'-'A'(30h,41h): Message length (10byte)
Message
STX (02h): Start of Message
'C'-'B'-'0'-'C' (43h, 42h, 30h, 43h): Security password Reply Command
'0'-'1' (30h, 31h): Enable Write
ST: Error Status
00h: No Error
01h: Error
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(128/141)

23. LAN MAC Address
23.1 LAN MAC Address Read
This command is used in order to read the MAC Address.
1) The controller requests the monitor to read MAC Address
Header
SOH-'0'-Monitor ID'0'-'A'-'0'-'8'

Message
STX-'C'-'2'-'2'-'A'-'0'-'2'-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h) : Start of Header
'0' (30h) : Reserved
Monitor ID : Specify the Monitor ID from which you want to get status.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h) : Message sender is the controller.
'A' (41h) : Message Type is "Command".
'0'-'8' (30h, 38h) : Message length is 8 bytes.
Message
STX (02h): Start of Message
'C'-'2'-'2'-'A': LAN read command.
‘0’-‘2’: MAC Address
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies MAC Address to the controller.
Header
SOH-'0'-'0'-Monitor ID'B'-LN(H)-LN(L)

Message
STX-'C'-'3'-'2'-'A'-RC-'0'-'2'IPV-MAC(0)-....-MAC(n)-ETX

Check code
BCC

Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message Type is "Command reply".
LN(H)-LN(L): Message length (byte length), from STX to ETX
Message
STX(02h):Start of Message
'C'-'3'-'2'-'A': LAN read reply command.
RC: Reply result Code
'0'-'0' (30h, 30h): Normal
'F'-'F' (46h, 46h): Abnormal
'0'-'2': MAC Address
IPV: IPv4 or IPv6
'0'-'4' (30h, 34h): IPv4
'0'-'6' (30h, 36h): IPv6
MAC(0-n): MAC Address
In the case of IPv4 -> n = 4

(129/141)

Delimiter
CR

In the case of IPv6 -> n = 7
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(130/141)

24. Proof of Play
24.1 Start Proof of Play
This command is used in order to read Proof of Play log data.
1) The controller requests the monitor to start Proof of Play.
Header
SOH-'0'-Monitor ID'0'-'A'-'0'-'8'

Message
STX-'C'-'A'-'0'-'6'-'0'-'0'-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h) : Start of Header
'0' (30h) : Reserved
Monitor ID : Specify the Monitor ID from which you want to get status.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h) : Message sender is the controller.
'A' (41h) : Message Type is "Command".
'0'-'8' (30h, 38h) : Message length is 8 bytes.
Message
STX (02h): Start of Message
'C'-'A'-'0'-'6': Proof of Play command
'0'-'0' (30h,30h): Start Proof of Play command
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

2) The monitor replies the result of Start to the controller.
Header
SOH-'0'-Monitor ID'0'-'B'-'2'-'2'

Message
STX-'C'-'B'-'0'-'6'-'0'-'0'-Data(0)Data(1)-Data(2) --- Data(12) -ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h) : Start of Header
'0' (30h) : Reserved
Monitor ID : Specify the Monitor ID from which you want to get status.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h) : Message sender is the controller.
'A' (41h) : Message Type is "Command".
'2'-'2' (32h, 32h) : Message length is 34 bytes.
Message
STX (02h): Start of Message
'C'-'B'-'0'-'6': Proof of Play reply command
'0'-'0' (30h,30h): Start Proof of Play command
Data(0)-Data(12): Log Data of Proof of Play of STOP (26byte) : Same as “Get Proof of Play
Current”
※
Refer to “Get Proof of Play Current”
ETX (03h): End of Message
Check code
BCC: Block Check Code
(131/141)

Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(132/141)

24.2 Stop Proof of Play
This command is used in order to stop Proof of Play log data.
1) The controller requests the monitor to stop Proof of Play.
Header
SOH-'0'-Monitor ID'0'-'A'-'0'-'8'

Message
STX-'C'-'A'-'0'-'6'-'0'-'1'-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h) : Start of Header
'0' (30h) : Reserved
Monitor ID : Specify the Monitor ID from which you want to get status.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h) : Message sender is the controller.
'A' (41h) : Message Type is "Command".
'0'-'8' (30h, 38h) : Message length is 8 bytes.
Message
STX (02h): Start of Message
'C'-'A'-'0'-'6': Proof of Play command
'0'-'1' (30h,31h): Stop Proof of Play command
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

2) The monitor replies the result of Stop to the controller.
Header
SOH-'0'-Monitor ID'0'-'B'-'2'-'2'

Message
STX-'C'-'B'-'0'-'6'-'0'-'1'-Data(0)Data(1)-Data(2) --- Data(12) -ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h) : Start of Header
'0' (30h) : Reserved
Monitor ID : Specify the Monitor ID from which you want to get status.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h) : Message sender is the controller.
'A' (41h) : Message Type is "Command".
'2'-'2' (32h, 32h) : Message length is 34 bytes.
Message
STX (02h): Start of Message
'C'-'B'-'0'-'6': Proof of Play reply command
'0'-'1' (30h,31h): Stop Proof of Play command
Data(0)-Data(12): Log Data of Proof of Play of STOP (26byte) : Same as “Get Proof of Play
Current”
※
Refer to “Get Proof of Play Current”
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.

(133/141)

Delimiter
CR (0Dh): End of packet

(134/141)

24.3 Get Proof of Play Current
This command is used in order to get Proof of Play current log.
1) The controller requests the monitor to get current log of Proof of Play.
Header
SOH-'0'-Monitor ID'0'-'A'-'0'-'8'

Message
STX-'C'-'A'-'0'-'6'-'0'-'2'-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h) : Start of Header
'0' (30h) : Reserved
Monitor ID : Specify the Monitor ID from which you want to get status.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h) : Message sender is the controller.
'A' (41h) : Message Type is "Command".
'0'-'8' (30h, 38h) : Message length is 8 bytes.
Message
STX (02h): Start of Message
'C'-'A'-'0'-'6': Proof of Play command
'0'-'2' (30h,32h): Get Proof of Play current log command
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

2) The monitor replies the current log of Proof of Play to the controller.
Header
SOH-'0'-Monitor ID'0'-'B'-'2'-'2'

Message
STX-'C'-'B'-'0'-'6'-'0'-'2'-Data(0)Data(1)-Data(2) --- Data(12) -ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h) : Start of Header
'0' (30h) : Reserved
Monitor ID : Specify the Monitor ID from which you want to get status.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h) : Message sender is the controller.
'A' (41h) : Message Type is "Command".
'2'-'2' (32h, 32h) : Message length is 34 bytes.
Message
STX (02h): Start of Message
'C'-'B'-'0'-'6': Proof of Play reply command
'0'-'2' (30h,32h): Get Proof of Play current log command
Data(0)-Data(12): Log Data of Proof of Play of STOP (26byte) : Same as “Get Proof of Play
Current”
-----------------------------------------*Log Data of Proof of Play : Data(0)-Data(12)
Data(0): Check INPUT PITURE
'0'-'0': No mean
'0'-'1': VGA
'0'-'2': RGB/HV
'0'-'3': DVI
'0'-'4': HDMI (Set only)

(135/141)

'0'-'5': VIDEO
'0'-'7': S-VIDEO
'0'-'C': Y/Pb/Pr
'0'-'D': OPTION
'0'-'E': Y/Pb/Pr2(SCART)
'0'-'F': DPORT
'1'-'0': DPORT2
'1'-'1': HDMI
'1'-'2': HDMI2
'8'-'0': DPORT3
Data(1)-Data(4) : Check Input Signal
'0'-'0'-'0'-'0'-'0'-'0'-'0'-'0' (30h,30h,30h,30h,30h,30h,30h,30h):No signal
'F'-'F'-'F'-'F'-'F'-'F'-'F'-'F' (46h,46h,46h,46h,46h,46h,46h,46h):Invalid signal
'*'-'*'-'*'-'*'-'*'-'*'-'*'-'*' (**h,**h,**h,**h,**h,**h,**h,**h):Input signal
Ex 1) 1920 x 1080
'0'-'7'-'8'-'0'-'0'-'4'-'3'-'8' : 1920(0780h) x 1080(0438h)
Data(5) : Check INPUT AUDIO
'0'-'0': No mean
'0'-'1': IN1
'0'-'2': IN2
'0'-'3': IN3
'0'-'4': HDMI
'0'-'6': OPTION
'0'-'7': DPORT
'0'-'8': DPORT2
'0'-'9': DPORT3
'0'-'A': HDMI2
Data(6) : Check with or without Audio
'0'-'0'(30h,30h): Audio in
'0'-'1'(30h,31h): No Audio in
'0'-'2'(30h,32h): N/A
Data(7) : Check status (Picture)
'0'-'0'(30h,30h): Normal Picture
'0'-'1'(30h,31h): No Picture
Data(8) : Check status (Audio)
'0'-'0'(30h,30h): Normal Audio
'0'-'1'(30h,31h): No Audio
Data(9)-Data(10) : hour
'*'-'*'-'*'-'*' (**h,**h,**h,**h):0~65535(0000h~FFFFh)
Data(11) : min
'*'-'*' (**h,**h):0~59(00h~3Bh)
Data(12) : sec
'*'-'*' (**h,**h):0~59(00h~3Bh)
-----------------------------------------ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(136/141)

24.4 Get Proof of Play Total Number
This command is used in order to get Proof of Play total number.
1) The controller requests the monitor to get the total number of Proof of Play data.
Header
SOH-'0'-Monitor ID'0'-'A'-'0'-'8'

Message
STX-'C'-'A'-'0'-'6'-'0'-'3'-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h) : Start of Header
'0' (30h) : Reserved
Monitor ID : Specify the Monitor ID from which you want to get status.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h) : Message sender is the controller.
'A' (41h) : Message Type is "Command".
'0'-'8' (30h, 38h) : Message length is 8 bytes.
Message
STX (02h): Start of Message
'C'-'A'-'0'-'6': Proof of Play command
'0'-'3' (30h,31h): Get Proof of Play Total Number command
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

2) The monitor replies the result the total number of Proof of Play data.
Header
SOH-'0'-Monitor ID'0'-'B'-'0'-'C'

Message
STX-'C'-'B'-'0'-'6'-'0'-'3'-TN(H)TH(L)-ETX

Check code
BCC

Header
SOH (01h) : Start of Header
'0' (30h) : Reserved
Monitor ID : Specify the Monitor ID from which you want to get status.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h) : Message sender is the controller.
'A' (41h) : Message Type is "Command".
'0'-'C' (30h, 43h) : Message length is 12 bytes.
Message
STX (02h): Start of Message
'C'-'B'-'0'-'6': Proof of Play reply command
'0'-'3' (30h,31h): Get Proof of Play Total Number command
TN(H): Total Number (High byte)
TN(L): Total Number (Low byte)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.

(137/141)

Delimiter
CR

Delimiter
CR (0Dh): End of packet

(138/141)

24.5 Get Proof of Play Number to Number
This command is used in order to get Proof of Play number to number log.
1) The controller requests the monitor to get Number to Number log of Proof of Play.
Header
SOH-'0'-Monitor ID'0'-'A'-'1'-'0'

Message
STX-'C'-'A'-'0'-'6'-'0'-'4'-BNS(H)BNS(L)-BNE(H)-BNE(L)-ETX

Check code
BCC

Delimiter
CR

Header
SOH (01h) : Start of Header
'0' (30h) : Reserved
Monitor ID : Specify the Monitor ID from which you want to get status.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h) : Message sender is the controller.
'A' (41h) : Message Type is "Command".
'1'-'0' (31h, 30h) : Message length is 16 bytes.
Message
STX (02h): Start of Message
'C'-'A'-'0'-'6': Proof of Play command
'0'-'4' (30h,34h): Get Proof of Play Number to Number log command
BNS(H): Block Number of Start (High byte)
BNS(L): Block Number of Start (Low byte)
BNE(H): Block Number of Stop (High byte)
BNE(L): Block Number of Stop (Low byte)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

2) The monitor replies the number to number log of Proof of Play to the controller.
Header
SOH-'0'-Monitor ID'0'-'B'-'2'-'6'

Message
Check code
Delimiter
STX-'C'-'B'-'0'-'6'-'0'-'4'- BN(H)BCC
CR
BN(L)-Data(0)-Data(1)-Data(2) --Data(12) -ETX
* A reply returns 13 bytes of data in order from specified Number to specified Number.
Ex) Number to Number:1 to 6
PC

Monitor

Request Number to Number (1 - 6)
Reply Log Data 13byte (Number 1)
Reply Log Data 13byte (Number 2)
Reply Log Data 13byte (Number 3)
Reply Log Data 13byte (Number 4)
Reply Log Data 13byte (Number 5)
Reply Log Data 13byte (Number 6)
Header
SOH (01h)

: Start of Header
(139/141)

'0' (30h) : Reserved
Monitor ID : Specify the Monitor ID from which you want to get status.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h) : Message sender is the controller.
'A' (41h) : Message Type is "Command".
'2'-'6' (32h, 36h) : Message length is 38 bytes.
Message
STX (02h): Start of Message
'C'-'B'-'0'-'6': Proof of Play reply command
'0'-'4' (30h,34h): Get Proof of Play Number to Number log command
BN(H): Block Number (High byte)
BN(L): Block Number (Low byte)
Data(0)-Data(12): Log Data of Proof of Play of STOP (26byte) : Same as “Get Proof of Play
Current”
* Refer to “Get Proof of Play Current”
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet

(140/141)

All data are subject to change without notice.
(April. 11, 2014)

Copyright 2004-2014 NEC Display Solutions, Ltd. All Right Reserved
This document provides the technical information for users. NEC Display Solutions, Ltd. reserves the right to change or modify the information contained
herein without notice. NEC Display Solutions, Ltd. makes no warranty for the use of its products and bears no responsibility for any errors or omissions which
may appear in this document.

(141/141)



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 141
Create Date                     : 2014:04:28 13:50:39+09:00
Modify Date                     : 2014:04:28 13:50:39+09:00
Producer                        : SkyPDF Pro for Softphone Version 1.10 Build ML32 0019.00
EXIF Metadata provided by EXIF.tools

Navigation menu