Nedap N V CONVEXS Inductive Proximity RFID Card Reader User Manual Convexs 80 series

N. V. Nederlandsche Apparatenfabriek NEDAP Inductive Proximity RFID Card Reader Convexs 80 series

Contents

User manual 01

Date : 11 April 2011 Version: 7
This information is furnished for guidance, and with no guarantee as to its accuracy or completeness; its publication conveys no licence under any patent or other right,
nor does the publisher assume liability for any consequence of its use; specifications and availability of goods mentioned in it are subject to change without notice; it is
not to be reproduced in any way, in whole or in part, without the written consent of the publisher.
© Nedap N.V., IDEAS P.O. Box 103 NL-7140 AC GROENLO The Netherlands
Page 1 of 4
Part.no.: 5268656
48
28
28
41
8,5
4.5
Convexs 80
Nedap Mifare dual technology readers
GENERAL
The Convexs reader enables smooth migration to Mifare card technology in existing Nedap XS, Nedap
AEOS and third party systems. The Convexs MN80 reads both Mifare and Nedap cards, the Convexs
M80 Mifare cards only. The Convexs output can be set to either Wiegand, XS RF modulation or
(encrypted) RS485 protocol. The Convexs MD80 reads Mifare DESFire cards.
Functionality and output is determined by the configuration of the Convexs reader. The configuration is
defined using the programm AEreco, and deployed by the configuration card or via AEmon. (More
information about configurations can be found in the Convexs_Invexs_InstallGuide_E.)
Three LED’s (red, green, blue) and beeper are included. The Convexs 80F can be flush mounted
(indoor / outdoor) in a electrical mounting box. Light (Gray) and Dark (Charcoal) fronts are available.
Dimensions: Convexs 80: 80 x 80 x 32 mm, Convexs 80F: 80 x 80 x 27 mm.
MOUNTING PROCEDURE CONVEXS
For mounting the Convexs the removable
backside must be placed on a wall. For removing
the backside of the Convexs gently push the two
lips at top and bottom towards the middle and
remove the backside. After the cable is
connected to the front (see ‘Connections’) the
front of the Convexs has to be clicked on the
backside.
MOUNTING PROCEDURE CONVEXS F
The Convexs F is opened by using the 2 small holes at the bottom and then
lifting the bottom side up. It can be mounted in a electrical mounting box.
Take care of the additional foam gasket and mounting direction (drain for
releasing eventually collected moisture must be on bottom side).
Attention: Don’t mount the Convexs F in a metal environment (Mifare
detection and Nedap AM detection can fail). For these applications use the
Convexs with the additional Protectors.
®
80
80
Convexs 80
32
Convexs
Convexs F
11
16
Ǿ 62.8
Convexs 80F
62.8
Ǿ 3.2
3.4x5.5
60
Convexs 80 series
© Nedap N.V. Convexs 80 series Installation sheet
Page 2 of 4
R
GND
UL*/NA* / BEEP
CONNECTIONS
The Convexs is not hot-swappable, so when making or changing connections be sure the power is
switched Off.
Remark:
Cable shield must be connected to Power GND of Convexs (A2) and GND of external device
(or metal case).
If connected to a 120kHz RF device (AEOS Nedap reader AEpack or XS device) the power is
supplied by the Convexs adapters (AX1014 for AEpacks, AB350 for the XS device). Existing
antenna cabling can then be reused for connecting the ConveXS.
UL*, NA* and BEEP are Open Collector to GND.
If the Convexs adapters are used, the original UL and NA signals are
converted to the UL* and NA*.
LED INDICATORS REARSIDE
There are two LED’s available: Blue for Status (of the application), Green for Identification
LED INDICATORS FRONTSIDE
At the front a three colour LED is positioned at the middle of the Convexs.
Depending of the used configuration the function of these LED’s can differ:
Green LED: Card is been authorised (UL led)
Red LED: Card is not authorised (NA led), controller is stand-by
Blue LED:
Blinks fast: No configuration is availabele at this Convexs (present Configuration
card or load Configuration first).
Continuously ON: Determined by configuration: E.g. Reader stand-by.
(Blue LED is activated if UL is OFF and NA is more than 1 sec OFF)
Remark:
Function of LED’s and Beeper is controlled by used application settings of Convexs. Green and
Red LED can be controlled by hardware signals (A8 and A10) or RS485NR, Blue LED indirectly
by UL and NA, if this setting is activated (configuration).
Beeper can be controlled by hardware signal (A7), RS485NR or software (configuration).
ID (green)
Blinking
Card detected
ST: STATUS (blue)
Slow blinking
Application running (operating)
Fast blinking
Downloading or error during loading
2 short flashes
Application present but not active
3 short flashes
No application present
Convexs
Function
A1
Power /
XSMOD
Power in (10-30VDC) /
XS modulator (120kHz)
A2
POWER GND/Shield
Power Ground
A3
A (-)
RS485
A4
B (+)
RS485
A5
D0
Wiegand Data 0
A6
D1
Wiegand Data 1
A7
BEEP
Beep input
A8
UL*
UL led input
A9
GND
Led Common Ground
A10
NA*
NA led input
Convexs Rear view
Convexs 80 series
© Nedap N.V. Convexs 80 series Installation sheet
Page 3 of 4
FIRMWARE
Pay attention that the firmware loaded in the Convexs together with the configuration determines
functionality and protocols.
Default (from factory) the Convexs handles the credentials on several simultaneously ways:
XS cards as: RS485NR, RF badge
Mifare cards (CSN) as: RS485NR, RF data
SYSTEM CONFIGURATIONS (how to connect Convexs readers)
Remark: Configurations can be determined by using the configuration card.
Attention: Check the Convexs_Invexs_InstallGuide chapter 10 vailable reader Firmware) for the
compatibility for the used readers.
TAMPER SWITCH
This tamper switch is an optical device, which is triggered by the amount of light. Depending on the
applied configuration the result of activating the tamper switch can differ.
BEEPER INDICATIONS
Beeper is also used for indication of loading the configuration:
High sound beep (‘happy sound’): Configuration is loaded correct, second high sound beep
indicates that this configuration can be used at this Convexs
Low sound beep (‘unhappy sound’): Configuration is not correct loaded or no configuration
available at startup.
Convexs uses existing antenna cabling (Coax +
3*0,25qmm for LED’s).
On each AEpack-RF interface an AX1014
(Convexs adapter) must be added.
Connections: see AX1014
RF interface AEpacks
Accessor III /
SimpleXS
AX1014
AX1014
AX1014
AX1014
AX1014
AB350
RF interface XS systems
Convexs uses existing antenna cabling (Coax +
3*0,25qmm for LED’s).
On each XS reader-RF interface an AB350
(Convexs adapter) must be added.
Connections: see AB350
To APx003 readers with RS485 special
encrypted protocol. (LED’s and beeper are
controlled over the RS485 communication)
AEOS RS485 interface
- Third party systems
- AEOS Wiegand
Wiegand interface
Wiegand output can be connected to Third party
systems (or to AEOS Wiegand readers). LED’s
and beeper are controlled by hard wiring.
Convexs 80 series
© Nedap N.V. Convexs 80 series Installation sheet
Page 4 of 4
SPECIFICATIONS Product nr: See table below: (e.g. Convexs MN80FG = 9856390)
Surface mounted
Flush mounted
G
C
FG
FC
Credentials
Convexs M80xx
9856250
9895400
9856420
9895540
Mifare
Convexs MD80xx
9856900
9895680
9857060
9895710
Mifare - DESFire
Convexs MN80xx
9856110
9895850
9856390
9895990
Mifare - Nedap
Convexs MND80xx
9896210
9896040
9896350
9896180
Mifare - Nedap DESFire
Gray
Charcoal
Flush, Gray
Flush, Charcoal
Gray=Light, Charcoal=Dark
Dimensions: Convexs: 80 x 80 x 32 mm, Convexs F: 80 x 80 x 27 mm
Protection: Convexs: IP54, Convexs F: IP65 Weight: ± 100 gr
Power Supply: 10VDC 30VDC Power consumption: 70mA@12VDC, 35mA@24VDC
Environment: Temperature: Operating: -20 55 °C, Storage: -30 65 °C Relative humidity: 10 93% non condensing
Tamper switch: Optical
Communication: RF Modulator (120 kHz for AX1014 or AB350)
Wiegand Data 0 and Data 1 (protocol depending of configuration)
RS485 (Encrypted AEOS protocol to APx003, (firmware APx003rs485NR) / RS485 plain
Inputs: Beeper Open collector to GND, max 20mA (Beep ON / OFF, controlled by application or hardware)
UL* led Open collector to GND, max 20mA
NA* led Open collector to GND, max 20mA
Indicators: UL (green) NA (red) ,MD (blue)
Antennas (internal): Antenna 1: 120 kHz, Nedap XS compatible (PM and AM cards). Detection distance UniXS card: 8 cm
Antenna 2: 13,56 MHz, Mifare compatible Detection distance Mifare card: 6 cm
Mifare EV1: 3 cm
R&TTE: Hereby, Nedap N.V., declares that these type Convexses are in compliance with the essential requirements
and other relevant provisions of Directive 1999/5/EC
CABLE SPECIFICATIONS
RS485: 2 x 2 x 0,25mm² shielded, max cable length: 1000 meter, cable capacity <= 100pF/meter
UL/GND/NA: 3 x 0,25mm², max cable length: 50 meter
XS MOD / GND: Coax RG58U, max cable length: 50 meter
Or 5 x 0,25mm² shielded, max cable length: 50 meter, cable capacity <= 100pF/meter
Wiegand: 4 x 0,25mm² shielded, max cable length: 150 meter, depending on receiving device.
MORE INFORMATION: For more detailed information contact your local Nedap supplier or check the internet site.
FCC and IC CERTIFICATIONS
Convexs MN80(F)X, Convexs MND80(F)X (X is G or C) for USA according to Part 15 with FCC ID:
CGDCONVEXS
Convexs MND80G for Canada according to RSS-210 with IC ID: 1444A-CONVEXS
Part 15.19(3) Labelling
This device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada.
Operating is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.
Cet appareil se conforme aux normes RSS 210 exemptés de license du Industry Canada.
L'opération est soumis aux deux conditions suivantes:
(1) cet appareil ne doit causer aucune interférence, et
(2) cet appareil doit accepter n'importe quelle interférence, y inclus interférence qui peut causer
une opération non pas voulu de cet appareil.