GIGASTOR

™

1
rev. 1

GigaStor User Guide

3
rev. 1

Trademark Notices
©2008 Network Instruments,® LLC. All rights reserved. Network Instruments, Observer® Gen2,TM and all associated logos are
trademarks or registered trademarks of Network Instruments, LLC.
Open Source Copyright Notices
Portions of this product include software developed by the OpenSSL Project for use in the OpenSSL Toolkit. (http://
www.openssl.org/), Copyright © 1998-2008 The OpenSSL Project. All rights reserved.
Portions of this product include software written by the University of Cambridge, Copyright © 1997-2008 University of
Cambridge All rights reserved. Redistribution and use in source and binary forms, with or without modification, are
permitted provided that the following conditions are met:
Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer.
Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following
disclaimer in the documentation and/or other materials provided with the distribution.
Neither the name of the University of Cambridge nor the name of Google Inc. nor the names of their contributors may be
used to endorse or promote products derived from this software without specific prior written permission.
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS “AS IS” AND ANY EXPRESS OR IMPLIED
WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR
ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED
TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING
NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.

Limited Warranty—Hardware
Network Instruments, LLC. (“Network Instruments”) warrants this hardware product against defects in materials and
workmanship for a period of 90 days from the date of shipment of the product from Network Instruments, LLC. Warranty is
for depot service at Network Instruments corporate headquarters in Minneapolis, MN, or Network Instruments’ London, UK
office. Warranties and licenses may give you more coverage in certain local jurisdictions; Network Instruments also offers
extended warranties as part of its maintenance agreement program.
If a defect exists during the initial warranty period or prior to expiration of a pre-paid maintenance program, at its option
Network Instruments will (1) repair the product at no charge, using new or refurbished replacement parts, or (2) exchange
the product with a product that is new or which has been manufactured from new or serviceable used parts and is at least
functionally equivalent to the original product. A replacement product assumes the remaining warranty of the original
product or 60 days, whichever provides longer coverage for you. When a product or part is exchanged, any replacement
item becomes your property and the replaced item becomes Network Instruments' property.
The information in this manual is furnished for informational use only, is subject to change without notice, and should not
be construed as a commitment by Network Instruments, LLC. Network Instruments, LLC assumes no responsibility or liability
for any errors or inaccuracies that may appear in this manual. Network Instruments, LLC does not warrant that the hardware
will meet your requirements or that the operation of the hardware will be uninterrupted or that the hardware will be errorfree.
Network Instruments, LLC SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT
LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL
Network Instruments, LLC BE LIABLE FOR ANY LOSS OF PROFIT OR ANY OTHER COMMERCIAL DAMAGE, INCLUDING BUT NOT
LIMITED TO SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR OTHER DAMAGES.
Network Instruments, LLC makes no other warranty, expressed or implied.

4
rev. 1

Limited Warranty—Software
Network Instruments, LLC (“DEVELOPER”) warrants that for a period of sixty (60) days from the date of shipment from
DEVELOPER: (i) the media on which the SOFTWARE is furnished will be free of defects in materials and workmanship under
normal use; and (ii) the SOFTWARE substantially conforms to its published specifications. Except for the foregoing, the
SOFTWARE is provided AS IS. This limited warranty extends only to END-USER as the original licensee. END-USER's exclusive
remedy and the entire liability of DEVELOPER and its suppliers under this limited warranty will be, at DEVELOPER or its
service center's option, repair, replacement, or refund of the SOFTWARE if reported (or, upon request, returned) to the party
supplying the SOFTWARE to END-USER. DEVELOPER does not warrant that the software will meet END-USER requirements,
and in no event does DEVELOPER warrant that the SOFTWARE is error free or that END-USER will be able to operate the
SOFTWARE without problems or interruptions.
Should DEVELOPER release a newer version of the SOFTWARE within 60 days of shipment of the product, DEVELOPER will
update the copy of the SOFTWARE upon request, provided request is made by the licensed END-USER within the 60 day
period of shipment of the new version. This update may consist of a CD or a manual or both at the discretion of DEVELOPER.
END-USER may be charged a shipping fee for updates.
The information in the SOFTWARE manuals is furnished for informational use only, is subject to change without notice, and
should not be construed as a commitment by DEVELOPER. DEVELOPER assumes no responsibility or liability for any errors or
inaccuracies that may appear in any SOFTWARE manual.
This warranty does not apply if the software (a) has been altered, except by DEVELOPER, (b) has not been installed, operated,
repaired, or maintained in accordance with instructions supplied by DEVELOPER, (c) has been subjected to abnormal
physical or electrical stress, misuse, negligence, or accident, or (d) is used in ultrahazardous activities.
DISCLAIMER. EXCEPT AS SPECIFIED IN THIS WARRANTY, ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS, AND
WARRANTIES INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A
PARTICULAR PURPOSE, NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING, USAGE, OR TRADE PRACTICE, ARE
HEREBY EXCLUDED TO THE EXTENT ALLOWED BY APPLICABLE LAW.
The above warranty DOES NOT apply to any beta software, any software made available for testing or demonstration
purposes, any temporary software modules or any software for which DEVELOPER does not receive a license fee. All such
software products are provided AS IS without any warranty whatsoever.
This License is effective until terminated. END-USER may terminate this License at any time by destroying all copies of
SOFTWARE including any documentation. This License will terminate immediately without notice from DEVELOPER if ENDUSER fails to comply with any provision of this License. Upon termination, END-USER must destroy all copies of SOFTWARE.
DEVELOPER makes no other warranty, express or implied.

Liability
IN NO EVENT WILL DEVELOPER OR ITS SUPPLIERS BE LIABLE FOR ANY LOST REVENUE, PROFIT, OR DATA, OR FOR SPECIAL,
INDIRECT, CONSEQUENTIAL, INCIDENTAL, OR PUNITIVE DAMAGES HOWEVER CAUSED AND REGARDLESS OF THE THEORY OF
LIABILITY ARISING OUT OF THE USE OF OR INABILITY TO USE THE SOFTWARE EVEN IF DEVELOPER OR ITS SUPPLIERS HAVE
BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
DEVELOPER SHALL NOT BE LIABLE FOR MATERIAL, EQUIPMENT, DATA, OR TIME LOSS CAUSED DIRECTLY OR INDIRECTLY BY
PROPER OR IMPROPER USE OF THE SOFTWARE. IN CASES OF LOSS, DESTRUCTION, OR CORRUPTION OF DATA, DEVELOPER
SHALL NOT BE LIABLE. DEVELOPER DOES NOT TAKE ANY OTHER RESPONSIBILITY.
In no event shall DEVELOPER's or its suppliers' liability to END-USER, whether in contract, tort (including negligence), or
otherwise, exceed the price paid by END-USER. The foregoing limitations shall apply even if the above-stated warranty fails
of its essential purpose.
DEVELOPER SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO,
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL DEVELOPER
BE LIABLE FOR ANY LOSS OF PROFIT OR ANY OTHER COMMERCIAL DAMAGE, INCLUDING BUT NOT LIMITED TO SPECIAL,
INCIDENTAL, CONSEQUENTIAL, OR OTHER DAMAGES.
DEVELOPER’S liability to the END-USER under this agreement shall be limited to the amount actually paid to DEVELOPER by
END-USER for the SOFTWARE giving rise to the liability.

5
rev. 1

Ownership and Confidentiality
END-USER agrees that Network Instruments, LLC owns all relevant copyrights, trade secrets and all intellectual property
related to the SOFTWARE.

End User License Agreement (EULA)
PLEASE READ THIS SOFTWARE LICENSE AGREEMENT CAREFULLY BEFORE DOWNLOADING OR USING THE SOFTWARE.
BY CLICKING ON THE “ACCEPT” BUTTON, OPENING THE PACKAGE, DOWNLOADING THE PRODUCT, OR USING THE
EQUIPMENT THAT CONTAINS THIS PRODUCT, YOU ARE CONSENTING TO BE BOUND BY THIS AGREEMENT. IF YOU DO NOT
AGREE TO ALL OF THE TERMS OF THIS AGREEMENT, CLICK THE “DO NOT ACCEPT” BUTTON AND THE INSTALLATION
PROCESS WILL NOT CONTINUE, RETURN THE PRODUCT TO THE PLACE OF PURCHASE FOR A FULL REFUND, OR DO NOT
DOWNLOAD THE PRODUCT.
The SOFTWARE is neither shareware nor freeware. The SOFTWARE is a commercial software package that is subject to
international copyright laws.
Single User License Grant: Network Instruments, LLC (“DEVELOPER”) and its suppliers grant to END-USER a nonexclusive and
nontransferable license to use the DEVELOPER software (“SOFTWARE”) in object code form solely on a single central
processing unit owned or leased by END-USER or otherwise embedded in equipment provided by DEVELOPER.
Multiple-Users License Grant: DEVELOPER and its suppliers grant to END-USER a nonexclusive and nontransferable license to
use the DEVELOPER SOFTWARE in object code form: (i) installed in a single location on a hard disk or other storage device of
up to the number of computers owned or leased by END-USER for which END-USER has paid individual license fees
purchased; or (ii) provided the SOFTWARE is configured for network use, installed on a single file server for use on a single
local area network for either (but not both) of the following purposes: (a) permanent installation onto a hard disk or other
storage device of up to the number of individual license fees purchased; or (b) use of the SOFTWARE over such network,
provided the number of computers connected to the server does not exceed the individual license fees purchased. ENDUSER may only use the programs contained in the SOFTWARE (i) for which END-USER has paid a license fee (or in the case of
an evaluation copy, those programs END-USER is authorized to evaluate) and (ii) for which END-USER has received a product
authorization keys (“PAK”). END-USER grants to DEVELOPER or its independent accountants the right to examine its books,
records and accounts during END-USER's normal business hours to verify compliance with the above provisions. In the event
such audit discloses that the Permitted Number of Computers is exceeded, END-USER shall promptly pay to DEVELOPER the
appropriate licensee fee for the additional computers or users. At DEVELOPER's option, DEVELOPER may terminate this
license for failure to pay the required license fee.
END-USER may make one (1) archival copy of the SOFTWARE provided END-USER affixes to such copy all copyright,
confidentiality, and proprietary notices that appear on the original.
EXCEPT AS EXPRESSLY AUTHORIZED ABOVE, END-USER SHALL NOT: COPY, IN WHOLE OR IN PART, SOFTWARE OR
DOCUMENTATION; MODIFY THE SOFTWARE; REVERSE COMPILE OR REVERSE ASSEMBLE ALL OR ANY PORTION OF THE
SOFTWARE; OR RENT, LEASE, DISTRIBUTE, SELL, OR CREATE DERIVATIVE WORKS OF THE SOFTWARE.
END-USER agrees that aspects of the licensed materials, including the specific design and structure of individual programs,
constitute trade secrets and/or copyrighted material of DEVELOPER. END-USER agrees not to disclose, provide, or otherwise
make available such trade secrets or copyrighted material in any form to any third party without the prior written consent of
DEVELOPER. END-USER agrees to implement reasonable security measures to protect such trade secrets and copyrighted
material. Title to SOFTWARE and documentation shall remain solely with DEVELOPER.
SOFTWARE, including technical data, is subject to U.S. export control laws, including the U.S. Export Administration Act and
its associated regulations, and may be subject to export or import regulations in other countries. END-USER agrees to
comply strictly with all such regulations and acknowledges that it has the responsibility to obtain licenses to export, reexport, or import SOFTWARE.
This License shall be governed by and construed in accordance with the laws of the State of Minnesota, United States of
America, as if performed wholly within the state and without giving effect to the principles of conflict of law. If any portion
hereof is found to be void or unenforceable, the remaining provisions of this License shall remain in full force and effect. This
License constitutes the entire License between the parties with respect to the use of the SOFTWARE.
Restricted Rights - DEVELOPER's software is provided to non-DOD agencies with RESTRICTED RIGHTS and its supporting
documentation is provided with LIMITED RIGHTS. Use, duplication, or disclosure by the Government is subject to the
restrictions as set forth in subparagraph “C” of the Commercial Computer SOFTWARE - Restricted Rights clause at FAR
52.227-19. In the event the sale is to a DOD agency, the government's rights in software, supporting documentation, and
technical data are governed by the restrictions in the Technical Data Commercial Items clause at DFARS 252.227-7015 and
DFARS 227.7202. Manufacturer is Network Instruments, 10701 Red Circle Drive, Minnetonka, MN 55343, USA.
6
rev. 1

Technical Support
Network Instruments provides technical support by phone (depending on where you are located):
US & countries outside Europe at (952) 358-3800
UK and Europe at +44 (0) 1959 569880
By fax (depending on where you are located):
US & countries outside of Europe at (952) 358-3801
UK and Europe at +44 (0) 1959 569881
Or by e-mail at:
US & countries outside of Europe: support@networkinstruments.com
UK and Europe: support@networkinstruments.co.uk
Network Instruments provides technical support for a period of 90 days after the purchase of the product at no charge. After
the 90-day initial support period, support will only be provided to those customers who have purchased a maintenance
agreement.
Telephone technical support hours are between 9:00 am and 5:00 pm (local time for each office).
Suggestions are welcomed. Many of the improvements made to our products have originated as end user suggestions.
Please submit detailed suggestions in writing to: support@networkinstruments.com or by fax at: (952) 358-3801. Please
submit any corrections to or criticism of Network Instruments’ publications to: pubs@networkinstruments.com or by fax at
(952) 358-3801.
To subscribe to the Network Instruments e-mail newsletter (delivered in HTML format), send an e-mail to
listserver@networkinstruments.com with the word “subscribe” in the subject line.

7
rev. 1

8
rev. 1

Contents

Chapter 1: About the GigaStor
GigaStor versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Chapter 2: Installing Your GigaStor
Unpacking and inspecting the parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing the GigaStor and connecting the cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Setting the GigaStor’s IP address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connecting Observer to the GigaStor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Redirecting the GigaStor probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Probe administration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GigaStor Capture Analysis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuring Observer for your Gigabit device. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Jumbo Frame Support (Gigabit Ethernet) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuring Terms of Service and Quality of Service settings . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuring Observer for your WAN device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital DS3/E3/HSSI Probe Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital T1/E1 Probe Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Serial T1/E1 Probe Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tapping an Ethernet or Fibre Channel connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10/100/1000, 10GbE Optical, and Fibre Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Gigabit copper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

18
19
19
22
22
24
29
31
31
32
33
34
35
36
37
37
40

9
rev. 1

Tapping a WAN connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
T1/E1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
DS3/E3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Installing the drives in your GigaStor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Connecting the GigaStor Expandable to the expansion units . . . . . . . . . . . . . . . . . . . . . . . . . . 52

Chapter 3: Packet Capture or GigaStor Capture
Capturing Packets with the GigaStor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Packet capture buffer and statistics buffer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

Chapter 4: GigaStor Control Panel
Display Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Right-click menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Analyze button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Configuring the GigaStor through the Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
GigaStor Options tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
GigaStor Chart tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
GigaStor Outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Capture Graph tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
GigaStor Schedule tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Statistics Lists tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Subnet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
GigaStor reports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Export . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77

Chapter 5: Using Observer with a WAN Probe
Discover Network Names. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Setting the Committed Information Rate (CIR) for a DLCI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
WAN Bandwidth Utilization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
WAN Vital Signs by DLCI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
WAN Load by DLCI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
WAN Top Talkers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
WAN Filtering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Triggers and Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88

Chapter 6: Forensic Analysis using Snort
Starting Forensic Analysis using Snort rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Creating a forensic analysis profile from the GigaStor control panel . . . . . . . . . . . . . . . . . . . . 94
About Forensic Analysis tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
About the Forensic Analysis Log tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Forensic Analysis Profile field descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Forensic Analysis Profile Settings tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Rules tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
10
rev. 1

Chapter 7: Observer on the GigaStor
Using the Observer console locally on the GigaStor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108

Chapter 8: Probe Instances
What is a probe instance? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112

Chapter 9: Gen2 Capture Card
Swapping the Gen2 card’s SFP or XFP interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
Configuring virtual adapters on the Gen2 card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
Viewing the Gen2 card’s properties and finding the board’s ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120

Appendix A: TCP/IP ports, NAT, and VPN
TCP/IP ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
NAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
VPN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125

Appendix B: GigaStor, GigaStor Expandable, and Expansion Unit Cases
GigaStor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GigaStor Expandable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Controller unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Expansion unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

128
129
129
130

Appendix C: GigaStor Portable
Running Observer passively . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
Using the portable GigaStor as a probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139

11
rev. 1

12
rev. 1

Chapter 1

About the GigaStor

13
rev. 1

Chapter 1 About the GigaStor

GigaStor versions
The GigaStor is an enterprise-strength network probe appliance. The
GigaStor combines a multi-terabyte, high-performance Redundant
Array of Independent Disks (RAID) with a dedicated, high-speed
network capture card in a modular, easy-to-deploy appliance.
There are these versions of the GigaStor:
Q
Q

Q

Q

GigaStor
GigaStor Expandable: a controller PC along with one, two, or
three disk expansion units that can store up to a total of 288
terabytes of data.
GigaStor SAN: a controller PC that connects to your SAN to
write its data. It uses a fibre channel host bus adapter that can
operate at 1, 2, or 4 Gigabit speed for connectivity.
GigaStor Portable: a portable GigaStor
Figure 1 GigaStor models

GigaStor

GigaStor Expandable

NOTE:

GigaStor SAN

GigaStor Portable

Unless specifically noted, all information in this manual
applies to all versions of the GigaStor: GigaStor, GigaStor
Expandable, GigaStor SAN, and GigaStor Portable.

If your GigaStor is configured to monitor Gigabit Ethernet, 10Gb
Ethernet, and Fibre Channel connections, the capture card is a Gen2
card with SFP (or XFP) modules. This allows you to hot-swap any
SFP-compliant connectors into the your appliance. This makes it

14 GigaStor versions
Chapter 1 About the GigaStor

rev. 1

possible to use the same probe to monitor different types of links as
needed. For example, you can easily convert the capture card from
optical to copper, allowing you to connect the GigaStor to different
test access points (TAPs) or switch port analyzer (SPAN) or mirror
interfaces.
If your GigaStor is configured to monitor WAN (such as E1, T1, E3,
DS3, or HSSI) connections, your GigaStor has a specialized WAN
capture card. It does not have SFP or XFP connectors.
The GigaStor can be used with the Expert Observer console or
Observer Suite to troubleshoot your network. Alternatively, you can
run the probe in “local console” mode, allowing you to analyze
GigaStor-collected data locally.The local console on the GigaStor is
Observer Expert. However, we recommend that you use Observer on
a remote system to analyze the data.

rev. 1

GigaStor versions 15
Chapter 1 About the GigaStor

16 GigaStor versions
Chapter 1 About the GigaStor

rev. 1

Chapter 2

Installing Your GigaStor

17
rev. 1

Chapter 2 Installing Your GigaStor

The general steps to install your GigaStor are:
F “Unpacking and inspecting the parts” on page 18
F “Installing the GigaStor and connecting the cables” on page 19
F “Connecting Observer to the GigaStor” on page 22
Additional steps to complete the installation are:
F “Configuring Observer for your Gigabit device” on page 31
F “Configuring Observer for your WAN device” on page 33
F “Tapping an Ethernet or Fibre Channel connection” on
page 37
F “Tapping a WAN connection” on page 42
F “Installing the drives in your GigaStor” on page 50

Unpacking and inspecting the parts
Your GigaStor includes a number of components. Take a moment
after unpacking the kit to locate all of the parts.
F One rack-mountable GigaStor system with an installed 10/
100/1000 Ethernet network interface (management) card.
F Appropriate capture interface (Gen2 or WAN).
F The rack unit may also include a rail kit depending on
which model was purchased.
F Windows XP 64-bit operating system and a restore DVD
specific for your GigaStor.
F TAP kits for your topology (Ethernet, Fibre Channel, or
WAN), except for the GigaStor 2TE.
F Cables
F Ethernet cable for each 10/100/1000 interface in your
GigaStor.
F Connection cables to connect your GigaStor to a TAP or
switch.

18 Unpacking and inspecting the parts
Chapter 2 Installing Your GigaStor

rev. 1

Installing the GigaStor and connecting the cables
1

Install the GigaStor and any expansion units into your rack using
the supplied rails. Instructions for installing the rail kits are
provided in the rail kit box.

2

Install the drives into the GigaStor and any expansion units. See
“Installing the drives in your GigaStor” on page 50.

3

Connect the GigaStor, TAP, and cables. See:
Q

Q

Q

Q

“Tapping an Ethernet or Fibre Channel connection” on
page 37 for details about optical and copper Gigabit Ethernet,
10 Gigabit Ethernet, and Fibre Channel connections.
“Tapping a WAN connection” on page 42 for details about
T1/E1 and DS3 connections.
“Connecting the GigaStor Expandable to the expansion units”
on page 52.
See the fibre channel host bus adapter (QLogic or other third
party) documentation included in the GigaStor packaging if
you are using a GigaStor SAN.

Setting the GigaStor’s IP address
At this point you have physically installed the hardware and
connected all the cables. Now, you must turn on the GigaStor and
configure the software.

rev. 1

1

Connect a monitor, keyboard, and mouse to the GigaStor and
ensure the GigaStor is plugged into a power outlet. These are only
needed temporarily to set the IP address. You can disconnect them
when you are finished. Alternatively, you can use Windows
Remote Desktop to connect to the GigaStor to make these
changes. The default IP address is 192.168.1.10.

2

If you are using a GigaStor Expandable, remember to start the
disk expansion units.

3

Turn on the system. On the back of the GigaStor ensure the
power switch is turned on. Then on the front of the GigaStor,
press the power button until the system starts to turn on.

Installing the GigaStor and connecting the cables 19
Chapter 2 Installing Your GigaStor

4

Ensure that each drive’s power/activity light is lit. If a drive’s light
is not lit, it is likely that the drive is not seated properly. Turn off
the GigaStor and reseat the drives. For more information, see
“Installing the drives in your GigaStor” on page 50.

5

Log in using the Administrator account. The default
Administrator password is admin.

6

Click Start →Control Panel →Network and Internet Connections
→Network Connections. Choose Local Area Connection and
right-click and choose Properties.

7

Select Internet Protocol (TCP/IP) from the list and click
Properties (Figure 2).
Figure 2 Default TCP/IP settings

8

Set the IP address, subnet mask, gateway, and DNS server for your
environment and click OK. Click OK again to close the Local
Area Connection Properties dialog. Close the Network
Connections window.

9

Right-click the Probe Service Configuration Applet in the system
tray and choose Open Probe Configuration.

20 Setting the GigaStor’s IP address
Chapter 2 Installing Your GigaStor

rev. 1

Figure 3 Probe Service Configuration Applet

10 The Probe Administration window opens. Click the Probe
Options tab (Figure 4).
Figure 4 Probe Options

11 Change the name of the probe to something meaningful to you.
The name might be the physical location of the probe. Click
Apply to save your changes and close the window.
By default the GigaStor runs the Expert Probe as a Windows
service and starts automatically at system startup. This prevents
you from using the Observer console on the GigaStor. You must
connect to the GigaStor using Observer on a different system. If
you want to use the Observer console locally, see “Using the
Observer console locally on the GigaStor” on page 108.

rev. 1

Setting the GigaStor’s IP address 21
Chapter 2 Installing Your GigaStor

Connecting Observer to the GigaStor
This section assumes you have already installed Observer on your
desktop or laptop. If not, install the software. You can download from
the Network Instruments website.
There are three main tasks to connect Observer to your GigaStor
Q

“Redirecting the GigaStor probe” on page 22

Q

“Probe administration” on page 24

Q

“GigaStor Capture Analysis” on page 29

Redirecting the GigaStor probe
1

Choose Start →All Programs →Observer →Observer. Observer
opens.

2

Select Actions →Redirect Probe (Figure 5).

Figure 5 Remote Probe Administration and Redirection

3

Click New to add the GigaStor to the Probe Administration and
Redirection list. Figure 6 appears.

22 Connecting Observer to the GigaStor
Chapter 2 Installing Your GigaStor

rev. 1

Figure 6 Edit Remote Probe Entry

4

Type the IP address that you assigned to the GigaStor in step 7 in
“Setting the GigaStor’s IP address” on page 19 and click OK. You
may leave the other fields blank. If you type a name, the name
will change after Observer connects to the remote probe. The
GigaStor appears in the list of probes available for redirection
(Figure 7).

Figure 7 Probe added to Remote Probe Administration and Redirection

5

rev. 1

Select the GigaStor probe and then click Redirect Selected Probe
(Figure 8).

Connecting Observer to the GigaStor 23
Chapter 2 Installing Your GigaStor

Figure 8 Probe Instance Redirection

6

Select the probe instance and click Redirect Selected Instance.
Figure 9 appears.

Figure 9 Redirecting Probe or Probe Instance

7

Choose the “Redirect to this Observer” option, then click the
Redirect button. Within 30 seconds the GigaStor will connect to
the local Observer. If you use NAT, see “NAT” on page 124.

8

Close the Probe Instance Redirection window.

Probe administration
Now that your GigaStor is connected to your Observer console, you
can administer it.

24 Connecting Observer to the GigaStor
Chapter 2 Installing Your GigaStor

rev. 1

1

Click Probe Administration (see Figure 7). The Probe
Administration Login window opens.
Figure 10 Remote Probe Administration

2

Ensure “Login using a user account configured for this Probe” is
selected and click OK.
The Probe Administration window opens to the Memory
Management tab (Figure 11).
Figure 11 Memory Management tab

3

rev. 1

Select the Network 1 probe instance and click Rename. Choose a
name that is meaningful to you for the probe instance name and
click OK. By default, Network 1 is your active probe instance for
your GigaStor. For details about active and passive probe instance,
see “Probe Instances” on page 111.

Connecting Observer to the GigaStor 25
Chapter 2 Installing Your GigaStor

By default all of the installed memory on the GigaStor is
dedicated for one probe instance. You must first release the
memory so that you can assign the freed memory to other probe
instances.
4

With the newly renamed probe instance still selected, click
Configure Memory (Figure 12) at the top of the window.

Figure 12 Edit Probe Instance: Capture Buffer Memory

5

Use the arrows to release some memory. Free enough memory to
create your probe instances and click OK. At a minimum each
probe instance requires12 MB memory. It uses 4 MB for statistics
and 8 MB for packet capture. Don’t worry about freeing too
much memory. If you determine you released too much, you can
reallocate it later to the capture buffer or operating system.
Because Observer operates in real-time, its buffers must always
remain in RAM; if the buffers resided in standard Windows user
memory, nothing would prevent the buffer file from being
swapped out to disk and subsequent packet loss. For this reason,
the probe reserves its memory from Windows upon startup so
that no other applications can use it and cause the buffer to be
swapped out to disk.
For more information about buffers, see “Packet capture buffer
and statistics buffer” on page 54.

6

Click the GigaStor Instances tab (Figure 13).

26 Connecting Observer to the GigaStor
Chapter 2 Installing Your GigaStor

rev. 1

Figure 13 GigaStor Instances

7

Click New Instance. Figure 14 appears.
Figure 14 Edit Probe Instance: Name

8

rev. 1

You are configuring a GigaStor probe to capture data and write it
to the hard drive. Therefore ensure “Probe instance” is selected in
the Instance type. Type a name and description and click Next.

Connecting Observer to the GigaStor 27
Chapter 2 Installing Your GigaStor

Figure 15 Edit Probe Instance: Configure Memory

9

From the RAM that you released earlier, assign some of it to this
probe instance and click Next.

10 Ensure the correct network adapter is selected and click Finish to
redirect the GigaStor to your local Observer console.
Figure 16 Edit Probe Instance: Connect to Console

28 Connecting Observer to the GigaStor
Chapter 2 Installing Your GigaStor

rev. 1

11 Repeat step 7 through step 10 until you have created all of your
probe instances. Any unused memory should be reallocated to the
packet capture buffer of the active probe instance or to the
operating system.
12 Click OK to close the Probe administration windows. After a
moment the GigaStor probe and any probe instances appear in
the Observer Probe list found along the left side of the main
Observer window.

GigaStor Capture Analysis
1

Click Capture →GigaStor Capture Analysis to begin viewing
network traffic that passes through the GigaStor probe. The
GigaStor Control Panel opens (Figure 17).
Figure 17 GigaStor Control Panel

At this point the data is not being written to disk unless you
manually click the Start button. With most GigaStor installations,
you want the GigaStor probe to always be writing its data to disk.
2

rev. 1

Click Settings in the middle of the top menu bar. The GigaStor
Settings window opens. Click the Schedule tab.

Connecting Observer to the GigaStor 29
Chapter 2 Installing Your GigaStor

Figure 18 GigaStor Settings Schedule tab

3

In the Schedule GigaStor Capture section, select Always. For
more information about a packet capture vs. GigaStor capture, see
“Packet Capture or GigaStor Capture” on page 53.

4

In the Reserve scheduling for section, select GigaStor and click
OK. You may receive a notice about scheduling reservation. If you
do, click Yes to change the scheduling.

You have installed your GigaStor! Now you must configure some
settings in Observer before getting the maximum results from your
new network analysis tool.
Q

Q

Q

If you are monitoring a Gigabit connection, you must
configure the WAN device. See “Configuring Observer for
your Gigabit device” on page 31 for details.
If you are monitoring a WAN connection, you must configure
the WAN device. See “Configuring Observer for your WAN
device” on page 33 for details.
If you are monitoring any other connection, begin using
Observer to analyze the data. To get started, take use the
GigaStor Control Panel. It is described in “GigaStor Control
Panel” on page 57.

30 Connecting Observer to the GigaStor
Chapter 2 Installing Your GigaStor

rev. 1

Configuring Observer for your Gigabit device
Depending on your probe and your network, you may need to make
some changes from the factory defaults.
Q
Q

“Jumbo Frame Support (Gigabit Ethernet)” on page 31
“Configuring Terms of Service and Quality of Service settings”
on page 32

Jumbo Frame Support (Gigabit Ethernet)
When a Gigabit Ethernet GigaStor is the selected probe, Observer
displays an additional Gigabit tab on the Probe or Device Setup
dialog. This allows you to adjust the maximum frame size. The default
is 1514 bytes (excluding the frame checksum), which is appropriate
for standard Ethernet. If the network link you are analyzing is
configured to support jumbo frames (i.e., frames larger than 1514
bytes) you may want to change this setting to match the frame size of
the Gigabit network, up to a maximum size of 9014 bytes. Observer
will then discard frames that exceed this maximum frame size,
generating a “Frame too large” error.

rev. 1

1

Select the gigabit probe and right-click. A menu appears. Choose
Probe or Device Settings.

2

Click the Gigabit tab (Figure 19).

3

Change the frame size to suit your needs and click OK.

Configuring Observer for your Gigabit device 31
Chapter 2 Installing Your GigaStor

Figure 19 Gigabit tab

Configuring Terms of Service and Quality of Service settings
The ToS/QoS settings are configured for each probe.
1

Select the gigabit probe and right-click. A menu appears. Choose
Probe or Device Settings.

2

Click the ToS/QoS tab (Figure 20).

3

Specify the IP precedence bits for the terms of service/quality of
service for your network.

32 Configuring Observer for your Gigabit device
Chapter 2 Installing Your GigaStor

rev. 1

Figure 20 ToS/QoS tab

Configuring Observer for your WAN device
There are a number of setup options and statistical displays unique to
WAN Observer, which are described in the following subsections.
Before you can analyze the WAN link, you must set some device
options. You must also have the appropriate administrative privileges
to change WAN device settings.
Q

“Digital DS3/E3/HSSI Probe Settings” on page 34

Q

“Digital T1/E1 Probe Settings” on page 35

Q

“Serial T1/E1 Probe Settings” on page 36

After configuring your connection, you should begin using Observer
to monitor your connections. To get started, use the information in
“Using Observer with a WAN Probe” on page 79.

rev. 1

Configuring Observer for your WAN device 33
Chapter 2 Installing Your GigaStor

Digital DS3/E3/HSSI Probe Settings
To access the probe settings, select the probe, right-click and choose
Probe or Device Settings. Then click the DS3/E3/HSSI tab
(Figure 21).
Figure 21 DS3/E3/HSSI Probe Settings

Table 1 describes fields in Figure 21.
Table 1 DS3/E3/HSSI probe settings
Setting

Explanation

WAN Type

Choose DS3 (T3), E3 or HSSI to match the type of link you are analyzing, then
choose the frame check sequence (FCS) standard: CRC-16 (the default) or CRC32.

Encapsulation

You must set this to match the settings on the frame relay CSU/DSU.

Subprotocol

If ATM or LAPB is the selected encapsulation method, you must choose the subprotocols on the link.

Fractionalized

Check if your link is configured for fractionalized operation. Fractionalized DS3
and E3 are not supported.

Bandwidth (HSSI)

Set to match the bandwidth and channel settings of the fractionalized HSSI link
under analysis.

34 Configuring Observer for your WAN device
Chapter 2 Installing Your GigaStor

rev. 1

Digital T1/E1 Probe Settings
To access the probe settings, select the probe, right-click and choose
Probe or Device Settings. Then click the T1/E1 tab (Figure 22).
Figure 22 T1/E1 WAN Probe Settings

Table 2 describes fields in Figure 22.
Table 2 T1/E1 WAN Probe Settings
Setting

Explanation

WAN/Frame Relay Type

Choose T1 or E1 to match the type of link you are analyzing.

Encapsulation

You must set this to match the settings on the frame relay CSU/DSU.

Subprotocol

If ATM or LAPB is the selected encapsulation method, you must choose the subprojects on the link.

Link 1 and Link 2 Channel Settings (Note that for the link and settings to be activated, you must check the
On check box for that link).
Fractionalized

Check if this link is configured for fractionalized operation.

Channel selector check
boxes

Choose the channels you want to be included in the analysis.

Include in Util.
Thermometer.

Check if you want to include statistics from this link in the Bandwidth Utilization
Thermometer.

rev. 1

Configuring Observer for your WAN device 35
Chapter 2 Installing Your GigaStor

Serial T1/E1 Probe Settings
Table 3 describes fields for a serial T1/E1 connection.
Table 3 Serial T1/E1 probe settings
Setting

Explanation

WAN/Frame Relay Type

Choose T1 or E1 to match the type of link you are analyzing.

Encapsulation

You must set this to match the settings on the frame relay router.

Fractionalized

Check if your link is configured for fractionalized operation.

Bandwidth

Set to match the bandwidth setting of the link you are analyzing.

36 Configuring Observer for your WAN device
Chapter 2 Installing Your GigaStor

rev. 1

Tapping an Ethernet or Fibre Channel connection
This section describes how to connect the cables for these
environments:
Q

Q

“10/100/1000, 10GbE Optical, and Fibre Channel” on
page 37
“Gigabit copper” on page 40

10/100/1000, 10GbE Optical, and Fibre Channel
The optical Ethernet kit includes:
Q
Q

Q

Optical TAP
One, two, or four full duplex optical cables depending on
which Gen2 card you purchased.
One, two, or four optical Y-analyzer cables

To connect the TAP to the GigaStor:

rev. 1

1

Insert the supplied SFP connectors (XPF connectors for 10GbE)
into the open slots on the back of the Gen2 card(s).

2

If you have a GigaStor Expandable, see “Connecting the GigaStor
Expandable to the expansion units” on page 52 for details about
connecting the expansion units. After connecting them, continue
with step 3.

3

Connect the TX Data Circuit-terminating Equipment (DCE) or
SAN port to the Link A port on the nTAP.

4

Connect the TX port on the Gigabit switch (DCE) or Fibre
Channel Fabric to the Link B port on the nTAP.

5

Use the Y-analyzer cable to connect the nTAP to the Gen2
capture card in the GigaStor. If you have more than one nTAP,
repeat for each additional nTAP.

Tapping an Ethernet or Fibre Channel connection 37
Chapter 2 Installing Your GigaStor

Figure 23 Gen2 card port assignments
1

1

1

1

1

3

1

1

5
1

DCE

2

DCE

2
DTE

DCE

2
DTE

3

2
2-port

6

NOTE: STRAIGHTTHROUGH CABLE

2

6
DTE

3
DCE

4

4-port

2

DCE
DTE

7
DCE

4
DTE

DCE

2
DCE

8
DTE

4

DTE
DTE

8-port: mainboard
and daughter board

2
2-port
10 Gb

Use the supplied Ethernet cable to connect the network interface
card in the GigaStor to the network.
If you are using a switch’s SPAN/mirror port, no nTAP is
required. Simply plug any straight-through or Fibre cable
between the SPAN/mirror port and one of the ports on the
Gen2 capture card.
Fibre Channel has auto-negotiation disabled by default. You
must enabled it first, then connect it to the SPAN or mirror
port on your switch.

Now that you have physically connected the cables for the GigaStor,
you must now configure its software. See “Setting the GigaStor’s IP
address” on page 19.
Figure 24 shows the GigaStor cabled to analyze a server. The TAP can
replace the connection between any DCE (Data Circuit-terminating
Equipment) and DTE (Data Terminal Equipment) device or
connection.

38 Tapping an Ethernet or Fibre Channel connection
Chapter 2 Installing Your GigaStor

rev. 1

Figure 24 GigaStor with an optical nTAP
Gen2

RX

Optical TAP

TX
RX

TX
RX

10/100/1000
NIC for TCP/IP

Server (DTE)

rev. 1

Gigabit Switch (DCE)

GigaStor or
GigaStor Expandable

Observer Console

Tapping an Ethernet or Fibre Channel connection 39
Chapter 2 Installing Your GigaStor

Gigabit copper
The Gigabit copper kit includes:
Q

Copper nTAP

Q

1, 2, or 4 standard Ethernet cables

Q

2, 4, or 8 analyzer cables

To connect the TAP to the GigaStor:
1

Insert the supplied SFP connectors into the open slots on the back
of the Gen2 card(s).

2

If you have a GigaStor Expandable, see “Connecting the GigaStor
Expandable to the expansion units” on page 52 for details about
connecting them. After connecting them, continue with step 3.

3

Connect the TX Data Circuit-terminating Equipment (DCE) or
SAN port to the Link A port on the nTAP.

4

Connect the TX port Gigabit switch (DCE) to the Link B port on
the nTAP.

5

Use the two analyzer cables to connect the analyzer port on the
nTAP to the Gen2 capture card in the GigaStor. If you have more
than one nTAP, repeat for each additional nTAP.

Figure 25 8-port Gen2 card port assignments
1

1

1

1

1
DCE

2

1
DCE

2
DTE

DTE

3

4

2-port

4-port

40 Tapping an Ethernet or Fibre Channel connection
Chapter 2 Installing Your GigaStor

DTE

7
DCE

4
DTE

DCE

6
DTE

DCE

2

5
DCE

2

3

2

3

2

DCE

8
DTE

4

DTE

8-port: mainboard
and daughter board

rev. 1

6

NOTE: PASS-THROUGH
CABLE

Use the supplied Ethernet cable to connect the network interface
card in the GigaStor to the network.
If you are using a switch’s SPAN/mirror port, no nTAP is
required. Simply plug any straight-through Ethernet cable
into the SPAN/mirror port on the switch and one of the ports
on the Gen2 capture card.

Now that you have physically connected the cables for the GigaStor,
you must now configure its software. See “Setting the GigaStor’s IP
address” on page 19.
Figure 26 shows the GigaStor as it would be cabled to analyze a
server. The TAP can replace the gigabit connection between any DCE
(Data Circuit-terminating Equipment) and DTE (Data Terminal
Equipment) device or connection.
Figure 26 GigaStor with a copper TAP
Gen2

Gigabit
Copper TAP

10/100/1000
NIC for TCP/IP

Server (DTE)

rev. 1

Gigabit Switch (DCE)

GigaStor or
GigaStor Expandable

Observer Console

Tapping an Ethernet or Fibre Channel connection 41
Chapter 2 Installing Your GigaStor

Tapping a WAN connection
This section describes how to connect the cables for these
environments:
Q

“T1/E1” on page 42

Q

“DS3/E3” on page 46

T1/E1
See “Digital” on page 42 or “Serial” on page 44 depending on your
needs.

Digital
The digital T1/E1 kit includes:
Q

One T1/E1 dual link TAP

Q

One T1/E1 WAN analyzer cable

Q

Two T1/E1 Ethernet cables

1

If you have a GigaStor Expandable, see “Connecting the GigaStor
Expandable to the expansion units” on page 52 for details about
connecting them. After connecting them, continue with step 2.

2

Connect the TAP to the GigaStor using the T1/E1 WAN analyzer
cable.

3

From your T1/E1 cable that connects the DCE to your CSU/
DSU, unplug the CSU/DSU end and plug it into the Link 1 IN
port on the TAP.

4

Using one of the supplied T1/E1 Ethernet cables, connect the
Link 1 OUT port of the TAP to the CSU/DSU.

5

If you have a second T1 you want to monitor, repeat step 3 and
step 4 using Link 2.

6

Use the supplied Ethernet cable to connect the network interface
card in the GigaStor to the network.

42 Tapping a WAN connection
Chapter 2 Installing Your GigaStor

rev. 1

Now that you have physically connected the cables for the GigaStor,
you must now configure its software. See “Setting the GigaStor’s IP
address” on page 19.
Figure 27 shows the GigaStor as it would be cabled to analyze T1/E1
link with a Channel Service Unit/Data Service Unit (CSU/DSU)1.
Figure 27 Digital T1/E1 Tap
Gen2

T1 TAP

10/100/1000
NIC for TCP/IP

Router or
CSU/DSU (DTE)

T1 Line (DCE)

GigaStor or
GigaStor Expandable

Observer Console

1. The 4-Port version of this system has an additional PC interface card and an additional TAP and cable kit. Connect
the second TAP kit as shown in the diagram.

rev. 1

Tapping a WAN connection 43
Chapter 2 Installing Your GigaStor

Serial
The serial T1/E1 kit includes:
Q

One serial T1/E1 WAN TAP

Q

One serial Y cable

Q

One serial T1 WAN cable

1

If you have a GigaStor Expandable, see “Connecting the GigaStor
Expandable to the expansion units” on page 52 for details about
connecting them. After connecting them, continue with step 2.

2

Connect the TAP to the GigaStor using the serial T1/E1 WAN
cable.

3

Using the serial Y cable, connect it to the TAP and then to your
CSU/DSU and your router.

4

Use the supplied Ethernet cable to connect the network interface
card in the GigaStor to the network.

Now that you have physically connected the cables for the GigaStor,
you must now configure its software. See “Setting the GigaStor’s IP
address” on page 19.

44 Tapping a WAN connection
Chapter 2 Installing Your GigaStor

rev. 1

Figure 28 WAN Serial T1/E1 TAP

MODE

DTE
A

B

DCE
POWER

OUTPUT
ACTIVE

Serial T1/E1 TAP

10/100/1000
NIC for TCP/IP

CSU/DSU (DTE)

rev. 1

Router (DCE)

GigaStor or
GigaStor Expandable

Observer Console

Tapping a WAN connection 45
Chapter 2 Installing Your GigaStor

DS3/E3
See “Digital” on page 46 or “Serial/HSSI” on page 48 depending on
your needs.

Digital
The digital DS3/E3 kit includes:
Q

One digital DS3/E3 TAP

Q

One digital DS3/E3 WAN cable

Q

Two full-duplex DS3/E3 coax cables

1

If you have a GigaStor Expandable, see “Connecting the GigaStor
Expandable to the expansion units” on page 52 for details about
connecting them. After connecting them, continue with step 2.

2

Connect the TAP to the GigaStor using the supplied digital DS3/
E3 WAN cable.

3

From your coax cables that connects the router to your CSU/
DSU, unplug the ends of both cables connected to the CSU/DSU
and plug them into the IN ports on the TAP.

4

Using the supplied coax cables, connect them from the OUT
ports on the TAP to the CSU/DSU.

5

Use the supplied Ethernet cable to connect the network interface
card in the GigaStor to the network.

Now that you have physically connected the cables for the GigaStor,
you must now configure its software. See “Setting the GigaStor’s IP
address” on page 19.

46 Tapping a WAN connection
Chapter 2 Installing Your GigaStor

rev. 1

Figure 29 DS3/E3 TAP

DCE
E3

LOS

DTE
LOS

LOF

POWER IN

LOF

OUT

OUT

IN

DS3 TAP

IN (RX)

OUT (TX)

OUT (TX)

IN (RX)

CSU/DSU (DTE)

rev. 1

TX

DS3 Line (DCE)

RX

TX

RX

10/100/1000
NIC for TCP/IP

GigaStor or
GigaStor Expandable

Observer Console

Tapping a WAN connection 47
Chapter 2 Installing Your GigaStor

Serial/HSSI
The serial DS3 kit includes:
Q

One serial DS3/E3 TAP

Q

One HSSI Y-cable

Q

One HSSI cable

Q

One Ethernet cable

1

If you have a GigaStor Expandable, see “Connecting the GigaStor
Expandable to the expansion units” on page 52 for details about
connecting them. After connecting them, continue with step 2.

2

Connect the TAP to the GigaStor using the supplied HSSI Ycable.

3

From your serial HSSI cable that connects the router to your
CSU/DSU, unplug the CSU/DSU end and plug it into the IN port
on the TAP.

4

Using the supplied HSSI cable, connect it to OUT port on the
TAP.

5

Use the supplied Ethernet cable to connect the network interface
card in the GigaStor to the network.

Now that you have physically connected the cables for the GigaStor,
you must now configure its software. See “Setting the GigaStor’s IP
address” on page 19.

48 Tapping a WAN connection
Chapter 2 Installing Your GigaStor

rev. 1

Figure 30 WAN HSSI

HSSI OUT

HSSI IN

HSSI TAP

10/100/1000
NIC for TCP/IP

CSU/DSU (DTE)

rev. 1

Router (DCE)

GigaStor or
GigaStor Expandable

Observer Console

Tapping a WAN connection 49
Chapter 2 Installing Your GigaStor

Installing the drives in your GigaStor
CAUTION HANDLING
THE DRIVES

Be especially careful when handling and installing the hard
drives. Proper handling is paramount to the longevity of the
unit. The internal mechanism of the hard drive can be
seriously damaged if the hard drive is subjected to forces
outside its environmental specifications.
When transporting the hard drive, always use the original
packaging in which the hard drive was delivered to you, and
avoid exposing the hard drive to extreme changes in
temperature to minimize the risk of condensation.
Q
Q

Q

Q

Never drop the unit. Handle it with care.
Never place the hard drive in the vicinity of equipment giving
off strong magnetic fields, such as CRT monitors, televisions,
or loudspeakers.
Always use an anti-static mat and wrist strap when handling
the hard drive. Hold the hard drive by the base and never
touch the components on the circuit board assembly.
If the temperature difference between the storage location
and installation location exceeds 50°F/10°C, for temperature
acclimation purposes, leave the hard drive in the new location
for at least two hours before turning it on.

Each drive for the GigaStor is packed in shock-resistant boxes. The
tray that holds each drive has two optical pipes that run along the
right side. These pipes are connected to the indicator lights on the
front of the tray and are prone to cracking or breaking if you squeeze
the sides of the tray too tightly.
Stickers on each drive identify which slot (and expansion unit) it
should be installed in. The drive labeled A1 must be installed in the
lower left slot. The disk expansion units for the GigaStor Expandable
are labeled A, B, or C on the back of the expansion unit’s case.
1

Open the locking latch by pushing the release tab until the tray
panel pops out.

2

Gently, but firmly, push the A1 drive into the appropriate slot
until you feel the pins engage and the latch closes slightly.

50 Installing the drives in your GigaStor
Chapter 2 Installing Your GigaStor

rev. 1

Figure 31 shows how the drive numbers correspond to slot
locations.
Figure 31 GigaStor drive locations
A7
A5
A3
A1

A8
A6
A4
A2
A1

1

14
10
6
2

15
11
7
3

16
12
8
4

!

rev. 1

!

GigaStor (8 drive)

Drive ID sticker

13
9
5
1

CAUTION GIGASTOR
EXPANDABLE DRIVE
LOCATION

2

1

2

A13
A9
A5
A1

A14
A10
A6
A2

A15
A11
A7
A3

A16
A12
A8
A4

A13
A9
A5
A1

A14
A10
A6
A2

A15
A11
A7
A3

A16
A12
A8
A4

B13
B9
B5
B1

B14
B10
B6
B2

B15
B11
B7
B3

B16
B12
B8
B4

C13
C9
C5
C1

C14
C10
C6
C2

C15
C11
C7
C3

C16
C12
C8
C4

GigaStor (16 drive)

GigaStor Expandable
expansion units

It is important that you install the drives in the correct drive
slot, and in correct expansion unit if you have a GigaStor
Expandable. Failure to install the drives in the proper order
will result in poor read/write performance or possibly RAID
array failure.

3

Push the latch in all the way until it clicks.

4

Repeat until all drives are in the chassis. For the GigaStor
Expandable continue with B1-B16 and C1-C16 as appropriate.

5

If you are installing a GigaStor Expandable, you must also connect
the cables. See “Connecting the GigaStor Expandable to the
expansion units” on page 52. Otherwise, continue with “Installing
the GigaStor and connecting the cables” on page 19.

Installing the drives in your GigaStor 51
Chapter 2 Installing Your GigaStor

Connecting the GigaStor Expandable to the expansion units
After you have installed the drives Use the supplied cables to connect
the expansion units to the GigaStor Expandable. Figure 32 shows how
to cable the GigaStor Expandable to the expansion units.
Figure 32 Cable diagram for the GigaStor Expandable
A1 2 3 4 B 1 2 3 4 C 1 2 3 4

A1 2 3 4

B1 2 3 4
B1 2 3 4

C1 2 3 4
C1 2 3 4

Otherwise, continue with “Installing the GigaStor and connecting the
cables” on page 19.
NOTE: GIGASTOR
EXPANDABLE

When turning the GigaStor Expandable components on and
off, follow this order to ensure proper drive recognition and
operation:

52 Installing the drives in your GigaStor
Chapter 2 Installing Your GigaStor

‹

Start the disk expansion units before turning on the
capture/controller PC unit.

‹

Shut down the capture/controller PC unit before turning
off the disk expansion units.

rev. 1

Chapter 3

Packet Capture or GigaStor Capture

53
rev. 1

Chapter 3 Packet Capture or GigaStor Capture

Capturing Packets with the GigaStor
A GigaStor can accumulate terabytes of stored network traffic. To
manage the sheer volume of data, the GigaStor includes an
alternative, specialized capture and analysis control panel. The
GigaStor Control Panel manages the capture, indexing, and storage of
large numbers of packets over long periods of time. While the
GigaStor control panel is active, standard packets captures are
unavailable. You cannot run the two types of captures simultaneously.
While actively capturing packets, the GigaStor control tracks network
statistics and indexes them by time as it saves the packets to disk. This
allows you to quickly scan the traffic for interesting activity and create
filters to focus on specific traffic using the slider controls and
constraint options.
The GigaStor control panel also automates storage management by
deleting the oldest data before storage runs out. This maintains a
multi-terabyte “sliding windows” of time within which you can review
and decode traffic. It also allows for passive (in other words, virtual)
probe instances, which allow users to have their own instances (and
security credentials) without duplicating data collection or storage.
You can view the sliding window as a time line chart. Depending on
what constraint are in effect and your display options determine what
appears on the chart. By using time selection sliders and other options,
you can quickly acquire and analyze the packets by clicking the
Analyze button. This opens the standard packet decode and analysis
window. From there you can view packets, save them, and perform
further filtering if desired.

Packet capture buffer and statistics buffer
There are two kinds of buffers that a probe uses to store data in realtime: capture buffers and statistical buffers. The capture buffer stores
the raw data captured from the network while the statistical buffer
stores data entries that are snapshots of a given statistical data point.
Selecting an appropriate capture buffer size given system resources is
all most users need to worry about; the default settings for the
statistical buffers work perfectly fine in the vast majority of
circumstances.
54 Capturing Packets with the GigaStor
Chapter 3 Packet Capture or GigaStor Capture

rev. 1

However, if you are pushing the limits of the system on which the
probe is installed by creating many probe instances, you may be able
to avoid some performance problems by fine-tuning the memory
allocation for each probe instance.
For example, suppose you want to give a number of remote
administrators access to Top Talkers data from a given probe. You will
be able to add more probe instances within a given system’s memory
constraints if you set up the statistics buffers to only allocate memory
for tracking Top Talkers and to not allocate memory for statistics that
no one will be looking at.
Observer has no limitations on the amount of RAM that can be used
for a buffer.
You can allocate up to 4 gigabytes, limited only by the physical
memory installed on your Windows system. Note that when run on a
64-bit Windows, there is no 4 GB limitation for the capture buffer;
you are limited only by the amount of physical memory installed on
the probe.
In all cases, the actual buffer size (Max Buffer Size) is also reduced by
7% for memory management purposes. Should you try and exceed the
Max Buffer Size an error dialog will be displayed indicating the
minimum and maximum buffer size for your Observer (or probe)
buffer.
For passive probe instances, which are most often used for
troubleshooting, the default settings should be sufficient. If you are
creating an active probe instance (one that writes to disk and not just
reads from it), then you may want to use the following formula as a
rough guideline to determine how much RAM to reserve for the
probe instance when doing a packet capture. (This formula does not
apply when doing a GigaStor capture to disk. It is only for passive
probe instances doing packet captures.)
Network Speed × Average Throughput (MB/second) = Seconds of data storeable in RAM

TIP ! C APTURE
B UFFER

rev. 1

You want a buffer that will handle your largest, worst case
burst.

Packet capture buffer and statistics buffer 55
Chapter 3 Packet Capture or GigaStor Capture

56 Packet capture buffer and statistics buffer
Chapter 3 Packet Capture or GigaStor Capture

rev. 1

Chapter 4

GigaStor Control Panel

57
rev. 1

Chapter 4 GigaStor Control Panel

Once the GigaStor is up and running on the network, you can run
Expert Observer or Observer Suite to connect to the GigaStor
running as a probe to begin analyzing the network, or you can run the
GigaStor in Console mode via Windows Terminal Server (or a
monitor and keyboard that are physically attached). Observer works
with the GigaStor just as it does any other Network Instruments
probe, with some GigaStor-specific enhancements (described below).
The GigaStor Control Panel is available from the probe itself (when
running in Console Mode), and also from any Observer Expert or
Observer Suite console when it is connected to a GigaStor. In either
case, choose GigaStor Capture Analysis from Observer’s Capture
menu, and a screen like the following is displayed:
Figure 33 GigaStor Control Panel

The GigaStor Control Panel shows traffic on a time line graph,
allowing you to select packets for decoding, analysis, and display by
defining the time period you want to view, and the types of packets
you want to include.
Use the sliders at the top of the time line chart to select the time
period you are interested in analyzing. If desired, you can further
constrain the display of packets by MAC Stations, IP Stations, IP Pairs,

58
Chapter 4 GigaStor Control Panel

rev. 1

etc., by clicking on the appropriate tab and selecting the items you
want to see on the time line chart.

Display Controls
Charts and statistical tables are refreshed only when you click the
Update Chart or Update Statistics button. The buttons will flash with
a red border when a refresh is necessary. You can also have the display
auto-update. For details, “GigaStor Options tab” on page 64.
You can change the Screen resolution (in other words, the time scale)
and which Data type (i.e., packets or bytes, either per second or
totals) to chart by using the drop-down controls and per second check
box. The Statistics interval control lets you display network statistics
based on the entire visible chart, or only show data derived from the
time interval you have selected to analyze.
The FIFO gauge on the right side of the control pane tracks how well
GigaStor’s disk hardware is keeping up with the current traffic load; if
the FIFO gauge shows 90% or greater, you should consider reducing
the load using one or more of the following methods:
Q

Q

Q

Allocate more memory to the GigaStor instance. See the
instructions in “Probe administration” on page 24 for details
about allocating memory for the probe instance.
Activate dynamic sampling, or increase the fixed sampling
ratio. See details about packet capture in “Packet capture
buffer and statistics buffer” on page 54.
Activate partial packet capture or reduce the size of portion
captured. See details about partial packet capture in “Capture
partial packets” on page 65.

The Rate: field shows how much traffic the GigaStor will be able to
archive given the active instance’s current disk usage rate. It is updated
dynamically as the usage rates change. To increase the archivable time
window, activate partial packet capture and sampling as described
above, or apply pre-filtering.

rev. 1

Display Controls 59
Chapter 4 GigaStor Control Panel

Right-click menus
As with other Observer displays, the charts and tables of the GigaStor
control panel offer many right-click shortcuts.
Q

Right-clicking on the chart portion of the Control Panel
displays the following options for navigating and displaying
traffic data:
Figure 34 Chart right-click menu

Q

Q

Settings brings up GigaStor Control panel settings; the Zoom
to Cursor Click Position options let you select from different
chart resolutions, centering the display at the current cursor
position.
Right-clicking on any table (such as Summary, TCP, UDP,
etc.) presents a context-sensitive menu. The TCP right-click
menu is typical:
Figure 35 TCP right-click menu

Q

60 Right-click menus
Chapter 4 GigaStor Control Panel

The options themselves are self-explanatory. Filtering options
displayed depend on which table you right-clicked on.

rev. 1

Analyze button
Figure 36 GigaStor Control Panel Analyze button

When you click the Analyze button to view the results, you are
prompted to select how to filter the packet capture for display
(Figure 37).
After you click OK, any filters you have chosen are applied, and a
standard decode window is displayed, unless you have checked the
“Display selected filter before starting analysis” option, in which case
the filter editor is displayed.

rev. 1

Analyze button 61
Chapter 4 GigaStor Control Panel

Figure 37 GigaStor Analysis Options window

Table 4 describes what the fields in the various sections control.
Table 4 GigaStor Analysis Options
Field section

Description

GigaStor Analysis Filter

Choose whether to Analyze all traffic in the analysis period, Select
an Observer filter to apply before decoding, or Create an analysis
filter using checked GigaStor entries (in other words, based on the
constraints you have selected using the GigaStor control panel).
Subsequent check boxes let you choose which criteria from the
Control Panel selection to include in the analysis. The Include
expert information in analysis filter option should be checked if
you plan on using Observer’s Expert Analysis on the packet buffer;
otherwise leave it unchecked.

Analysis Time Range

Set the start and end time for analysis. The fields are pre-filled
based on the time slider selections made from the GigaStor
Control Panel.

Analysis Type

Choose between Expert analysis and decode, Decode without
expert analysis, or Forensic analysis only. Load time is significantly
reduced (especially with large files) by bypassing analysis
processing for features you are not interested in.

Forensic Analysis

Select a Forensic Analysis profile. See “Starting Forensic Analysis
using Snort rules” on page 92 for details on using this Snortcompatible feature.

62 Analyze button
Chapter 4 GigaStor Control Panel

rev. 1

Configuring the GigaStor through the Control Panel
Just as with the standard Observer packet capture interface, you can
set the colors of the capture graph and schedule captures to be
automatically launched (or to run all the time). In addition, there are
a number of GigaStor-specific settings that allow you to fine-tune
performance based on your particular needs.
1

Open the GigaStor Control Panel (Capture →GigaStor Capture
Analysis).

2

Click the Settings button.

3

Click the tab for the settings you want to change.

Figure 38 GigaStor Control Panel Analyze button

These options and settings are described in

rev. 1

Q

“GigaStor Options tab” on page 64

Q

“GigaStor Chart tab” on page 67

Q

“GigaStor Outline” on page 67

Q

“Capture Graph tab” on page 69

Q

“GigaStor Schedule tab” on page 70

Q

“Statistics Lists tab” on page 71

Q

“Subnet” on page 72

Q

“GigaStor reports” on page 75

Q

“Export” on page 77

Configuring the GigaStor through the Control Panel 63
Chapter 4 GigaStor Control Panel

GigaStor Options tab
This tab lets you configure many options for the GigaStor. Follow the
instructions in “Configuring the GigaStor through the Control Panel”
on page 63 to open the GigaStor Options tab (Figure 39).
Figure 39 GigaStor Options tab

See Table 5 for a description of each field of the GigaStor Options tab.

64 Configuring the GigaStor through the Control Panel
Chapter 4 GigaStor Control Panel

rev. 1

Table 5 GigaStor Options tab
Field

Description

Capture Buffer size

Allows you to set the amount of Windows memory that Observer
will dedicate to the capture buffer cache for this instance. Values
are in megabytes. This configuration value has been pre-set for
optimum performance given a single GigaStor collection instance.
The factory settings also allow enough memory to set up a number
of passive or virtual instances, which will allow multiple users to
view the analysis results while avoiding redundant processing,
memory, and disk storage consumption.
If you wish to run multiple collection instances to monitor multiple
links or networks, you can decrease the capture buffer size
dedicated to GigaStor collection which will release some memory
for creating other probe collection instances, but be careful.
Inadequate memory allocation to GigaStor collection can affect
performance and result in dropped packets during high load
periods.
A GigaStor Instance can be as large as the physical memory
installed on your system after subtracting the memory dedicated
to Windows and other probe Instances.
To change the allocation for this probe instance, click the Configure
button, which will display the probe Instance, Memory and Security
Administration dialog.
In all cases, the actual buffer size (Max Buffer Size) is also reduced
by 7% for memory management purposes. Should you try to
exceed the Max Buffer Size an error dialog will be displayed
indicating the minimum and maximum buffer size for your
Observer (or probe) buffer.

Do not include traffic from Observer/
Probe local MAC address

Excludes packets sent and received from the station running
Observer or probe (the MAC address of the station from which you
are capturing packets).

Capture partial packets

By default, Observer will capture the entire packet. This option
allows you to define a specific amount of each packet to capture to
the buffer. For example, a setting of 64 bytes will result in Observer
only capturing the first 64 bytes of every packet.
Most of the pertinent information about the packet (as opposed to
the information contained in the packet) is at the beginning of the
packet, so this option allows you to collect more packets for a
specific buffer size by only collecting the first part of the packet. In
some forensic situations, a warrant may only allow an officer/agent
to collect, for example, e-mail headers.
Also, if the system is having trouble keeping up with bandwidth
spikes, collecting partial packets can resolve the issue. To change
the number of bytes captured in each packet, click the Change
Size...
Note that this setting affects all consoles that connect to this probe.
You cannot change this setting unless you have administrative
privileges to do so.

Network Load

When checked, Observer will not strip out the informational
markers used by Expert Time Interval and What If analysis modes.
Leave this box unchecked unless you intend to use these modes.

rev. 1

Configuring the GigaStor through the Control Panel 65
Chapter 4 GigaStor Control Panel

Table 5 GigaStor Options tab
Field

Description

Start/Stop Packet Capture marker
frames

When checked, saved packet capture buffers will include markers
that timestamp when packet captures were started and stopped.

Wireless Channel Change

When checked, saved packet capture buffers will include markers
that show what channel was currently being listened to. This is
useful if you are using Wireless Site Survey to scan channels.

Packet Sampling

Packet sampling applies to the control panel statistical displays, not
saved packets. On probes connected to highly-saturated networks
(especially multi-port probes), sometimes it is desirable to adjust
the rate of statistical indexing to conserve probe processing and
storage resources. The default (and recommended) setting is for
Observer to automatically scale back the packets it uses to update
the console display based on system load. Alternatively, you can
specify a Fixed Sampling Ratio to consider when updating the
GigaStor Control Panel Charts and statistical displays.

Capture Indexing Information
Maximums

Depending on what kinds of information you are interested in
tracking, you can conserve probe processing and espeically storage
resources by only indexing the information that is useful to you.
Of special note is the “Track statistics information per physical port”
option. When selected, causes the GigaStor to index the data it
collects by Gen2 capture card physical ports. You can then display
GigaStor Control Panel statistics by physical port (see the next
bullet item).

Display Indexing Information
Maximums

Depending on what kinds of information you are interested in
tracking, you can conserve probe processing and resources by only
indexing the information that is useful to you.

Collect and Show GigaStor indexing
information by

Depending on what kinds of information you are interested in
tracking, you can conserve probe processing and storage resources
by only indexing the information that is useful to you.

Track statistics information per
physical port

When selected, causes the GigaStor to index the data it collects by
Gen2 capture card physical ports. You can then display GigaStor
Control Panel statistics by physical port (see the next bullet item).

Use physical port selections to filter
statistics (requires per port tracking
information)

If the previous check box is selected, you can choose this option to
display, within the GigaStor Control Panel, statistics sorted by Gen2
Capture Card physical port. This is useful, for example, when you
want to troubleshoot the individual links without having to load
the capture buffer by clicking Analyze.

Stop capture when disk is full

When activated, the GigaStor stops capturing packets when the
disk array is full. The default behavior is to use circular (i.e. FIFO)
disk writes, causing the oldest buffer files to be overwritten as
newer traffic is captured.

Auto-update GigaStor chart on
statistics tab or selection change

When selected, causes the listed actions to have the same effect as
clicking the Update Chart/Statistics buttons.

Keep focus on GigaStor when
running Forensic Analysis and
creating a decode

Keeps the focus in the GigaStor Control Panel instead of switching
to the decode pane.

Update display during statistics
processing in 30 second intervals

When selected all charts will received updates in 30 second
intervals when processing statistics.

66 Configuring the GigaStor through the Control Panel
Chapter 4 GigaStor Control Panel

rev. 1

GigaStor Chart tab
This tab lets you choose the appearance, colors, and scale of the
GigaStor Control Panel’s time line chart. Follow the instructions in
“Configuring the GigaStor through the Control Panel” on page 63 to
open the GigaStor Chart tab (Figure 40).
Figure 40 GigaStor Chart tab

GigaStor Outline
Click Settings and the GigaStor Outline tab to modify the display of
the GigaStor outline graph. See Figure 33 on page 58 for an example
of the GigaStor outline graph. Follow the instructions in “Configuring
the GigaStor through the Control Panel” on page 63 to open the
GigaStor Outline tab (Figure 41).

rev. 1

Configuring the GigaStor through the Control Panel 67
Chapter 4 GigaStor Control Panel

Figure 41 GigaStor Outline

68 Configuring the GigaStor through the Control Panel
Chapter 4 GigaStor Control Panel

rev. 1

Capture Graph tab
Click Settings and the tab for the type of graph or chart for which you
want to set the display properties. Follow the instructions in
“Configuring the GigaStor through the Control Panel” on page 63 to
open the Capture Graph tab (Figure 42).
Figure 42 Capture Graph tab

Table 6 Capture Graph fields
Field

Description

Item

allows you to select which item will be configured.

Item color

allows you to select the color of the display item.

Item plot

allows you to select the item to be displayed as Lines or Bars. This
dropdown will only be active if “Lines” is selected in the “Item plot”
dropdown.

Item line thickness

allows you to select the thickness of the displayed item (in pixels).

Graph Time option buttons

allows you to set how the “X” axis will be displayed. Clock time will
show times using a 24-hour clock (i.e., the current time). Relative
time will display times from the start of the activation of the mode.

rev. 1

Configuring the GigaStor through the Control Panel 69
Chapter 4 GigaStor Control Panel

GigaStor Schedule tab
This tab lets you schedule GigaStor packet captures to occur at preset
times and days of the week. Although the dialog looks identical to the
standard Packet Capture schedule tab, the two types of schedules can
not be in effect at the same time. If you attempt to schedule GigaStor
packet captures when standard packet captures are already scheduled
(or the reverse), an error message is displayed.
Follow the instructions in “Configuring the GigaStor through the
Control Panel” on page 63 to open the Schedule tab (Figure 43).
Figure 43 Schedule tab

Q

Q

Choose No Scheduling to turn off any automatically
scheduled packet captures for the selected probe or probe
instance.
Choosing Always causes the selected probe or probe instance
to capture packets whenever the probe is running.

70 Configuring the GigaStor through the Control Panel
Chapter 4 GigaStor Control Panel

rev. 1

Q

Choose Daily at specified times or By day-of-week at
specified times to automatically schedule packet captures
during the specified time intervals (which you can add by
clicking the Add button at the bottom of the dialog; see
below).

Adding, Modifying, and Deleting Time Intervals
To add or modify a time interval to a schedule option, choose that
option (in other words, Daily or the day-of-week for which you want
to schedule a capture) and click the appropriate button. A time
interval specification dialog is displayed that allows you to set the time
period for the capture to be performed. To delete a time interval from
a schedule option, simply highlight the interval you wish to delete and
click the Delete button.
Time intervals include the last minute of the interval. All time periods
are specified in 24-hour (also known as military) time.

Statistics Lists tab
Observer tracks and makes many statistics available to you. You can
control how those statistics are displayed for your GigaStor. This tab
lets you customize how MAC address, IP address, IP Pair, and port
information are displayed in the various constraint tab statistical
listings. Follow the instructions in “Configuring the GigaStor through
the Control Panel” on page 63 to open the Statistics Lists tab
(Figure 44).

rev. 1

Configuring the GigaStor through the Control Panel 71
Chapter 4 GigaStor Control Panel

Figure 44 Statistics Lists tab

Subnet
You can specify subnet properties for the GigaStor. Follow the
instructions in “Configuring the GigaStor through the Control Panel”
on page 63 to open the Subnet tab (Figure 45).
Use the Add, Delete, Modify, and Delete All buttons to configure the
subnet settings for the GigaStor. When you define subnets in the
GigaStor, Observer adds that subnet information to the index files.
All future data analyzed will have subnet filtering readily available as
well as statistical data. On the IP stations tab you see your subnets and
you can perform statistical analysis based on subnets.
When you analyze data from captures with index files without any
subnets defined, there will be no subnet available in the IP stations tab
even if the analyzed data includes some index files with the new
subnet information.

72 Configuring the GigaStor through the Control Panel
Chapter 4 GigaStor Control Panel

rev. 1

Figure 45 GigaStor Subnet tab

Figure 46 shows how the subnet settings show up in the GigaStor
Control Panel. They appear on the IP Stations tab.

rev. 1

Configuring the GigaStor through the Control Panel 73
Chapter 4 GigaStor Control Panel

Figure 46 Subnet and IP Stations

74 Configuring the GigaStor through the Control Panel
Chapter 4 GigaStor Control Panel

rev. 1

GigaStor reports
There are several default reports available for you.
1

Follow the instructions in “Configuring the GigaStor through the
Control Panel” on page 63 to open the GigaStor Reports tab
(Figure 47).
Figure 47 GigaStor Reports tab

2

rev. 1

Select a report name and click Edit to change the report’s
characteristics (Figure 48).

Configuring the GigaStor through the Control Panel 75
Chapter 4 GigaStor Control Panel

Figure 48 Report Setup

3

Use the arrow buttons to position graphs and tables on your
report.

4

Double-click a section of the report to modify its caption, detail,
and number format (Figure 48).
Figure 49 Table Setup

76 Configuring the GigaStor through the Control Panel
Chapter 4 GigaStor Control Panel

rev. 1

Export
You can export your GigaStor-collected data on a scheduled basis. Use
the Export tab to configure when and to where your data is saved or
to manually export your data.
Follow the instructions in “Configuring the GigaStor through the
Control Panel” on page 63 to open the Export tab (Figure 50).
Figure 50 Exports tab

rev. 1

Configuring the GigaStor through the Control Panel 77
Chapter 4 GigaStor Control Panel

78 Configuring the GigaStor through the Control Panel
Chapter 4 GigaStor Control Panel

rev. 1

Chapter 5

Using Observer with a WAN Probe

79
rev. 1

Chapter 5 Using Observer with a WAN Probe

In general, the WAN analysis works much like Ethernet analysis. One
difference is that, when appropriate, Observer identifies WAN links
by their Data Link Connection Identifier (DLCI) rather than by MAC
address as is done with standard protocol analysis. In addition, many
WAN statistical modes break out the data by DCE, DTE, and
summary to reflect the full-duplex nature of WAN links. Modes
unrelated to WAN analysis are greyed out and unavailable.
The following sections describe how the available Observer modes
operate to analyze a WAN link.
Q

“Discover Network Names” on page 80

Q

“WAN Bandwidth Utilization” on page 82

Q

“WAN Vital Signs by DLCI” on page 83

Q

“WAN Load by DLCI” on page 84

Q

“WAN Top Talkers” on page 86

Q

“WAN Filtering” on page 87

Q

“Triggers and Alarms” on page 88

Discover Network Names
To access this mode, choose Tools →Discover Network Names
Discover Network Names mode will show DLCIs instead of MAC
addresses. You can also define the Committed Information Rate for
each DLCI you are monitoring with WAN Observer.

Setting the Committed Information Rate (CIR) for a DLCI
The Committed Information Rate defines the guaranteed bandwidth
for a WAN connection. If you want Observer’s WAN Vital Signs and
WAN Load by DLCI to monitor CIR compliance, you must specify
the CIR. A number of WAN triggers and alarms also use this
information, allowing you to be notified if the link is not performing
to the CIR.
For encapsulations that do not use DLCI (such as X.25), just use the
address scheme for your encapsulation.
80 Discover Network Names
Chapter 5 Using Observer with a WAN Probe

rev. 1

To set the CIR for a DLCI or group of DLCIs
1

Choose Tools → Discover Network Names. The Discover
Network Names pane opens.

2

In the pane, click the edit DLCI CIR button on the Discover
Network Names mode window (Figure 51).
Figure 51 Edit DCLI

3

Click Add to add a new DLCI.

4

Type the CIR in Kbits/sec for the DLCI.
Figure 52 DLCI Configuration dialog

rev. 1

Discover Network Names 81
Chapter 5 Using Observer with a WAN Probe

5

Click OK when you are done. For encapsulations that do not use
DLCI (such as X.25), the correct address value is shown even
though it is still labeled DLCI.

WAN Bandwidth Utilization
To see the percentages of bandwidth saturation on DCE, DTE and
DCE+DTE (Summary) for each configured link, choose Statistics →
Bandwidth Utilization. The mode starts automatically:
Figure 53 WAN bandwidth utilization

WAN links have two ports (DCE and DTE), so for a dual link T1, you
could display up to 5 charts (including the summary). The mode is
available in chart, pie, graph, and dial views. The display setup dialog
(click Settings to access), lets you choose what ports to display as well
as color and scale options.
NOTE: BANDWIDTH
UTILIZATION AND
FILTERS

The Bandwidth Utilization display is not subject to any filters
as it compares the actual activity on the network to the
network’s theoretical capacity.

82 WAN Bandwidth Utilization
Chapter 5 Using Observer with a WAN Probe

rev. 1

WAN Vital Signs by DLCI
In Observer, the Network Vital Signs display is replaced by the WAN
Vital Signs by DLCI mode. This mode provides a summary of the
errors occurring on a WAN link (E1/T1/DS3/E3).
Choose Statistics → WAN Vital Signs by DLCI.
You can choose what portion of traffic you wish to view from the list
box in the upper left corner of the window: DCE, DTE, DCE plus
DTE, and so forth.
Figure 54 WAN Vital Signs by DLCI pane

DTE (Data Terminal Equipment), in the context of a WAN link,
refers to the DSU/CSU. DCE (Data Circuit-terminating equipment)
refers to the WAN switch (which may reside remotely at the line
provider's site). Summary view shows a concatenation of traffic from
both ends of the link.
The following statistics are shown, broken down by DLCIs (which are
listed in the left most column). You can change the sort order by
clicking on any of the column headings:

rev. 1

WAN Vital Signs by DLCI 83
Chapter 5 Using Observer with a WAN Probe

Table 7 WAN statistics
Column

Description

DLCI

Data Link Connection Identifier of the statistics that follow. For encapsulations
that do not use DLCI (such as X.25), the correct address value is shown even
though it is still labeled DLCI.

DCE KBits/s Max

The maximum bit rate sensed so far from the DCE side of this DLCI, in Kbits per
second.

DTE KBits/s Max

The maximum bit rate sensed so far from the DTE side of this DLCI, in Kbits per
second.

DCE Kbits/s Avg

The average bit rate sensed on the DCE side of this DLCI, in Kbits per second.

DTE Kbits/s Avg

The average bit rate sensed on the DTE side of this DLCI, in Kbits per second.

DCE FECN under CIR

The number of packets seen on the DCE side of the link that had the Forward
Explicit Congestion Notification bit set, even though the bandwidth usage was
within the Committed Information Rate (CIR). Normally this number should be
zero. If bandwidth usage exceeds CIR, congestion is expected.

DTE FECN under CIR

The number of packets seen on the DTE side of the link that had the Forward
Explicit Congestion Notification bit set, even though the bandwidth usage was
within the Committed Information Rate (CIR). Normally this number should be
zero. If bandwidth usage exceeds CIR, congestion is expected.

DCE BECN under CIR

The number of packets seen on the DCE side of the link that had the Backward
Explicit Congestion Notification bit set, even though the bandwidth usage was
within the Committed Information Rate (CIR). Normally this number should be
zero. If bandwidth usage exceeds CIR, congestion is expected.

DTE BECN under CIR

The number of packets seen on the DTE side of the link that had the Backward
Explicit Congestion Notification bit set, even though the bandwidth usage was
within the Committed Information Rate (CIR). Normally this number should be
zero. If bandwidth usage exceeds CIR, congestion is expected.

WAN Load by DLCI
In a WAN installation, Observer’s Network Activity Display is called
WAN Load by DLCI. This mode shows critical WAN transfer rate and
congestion statistics in a number of formats. This display can show
you the health of a WAN link at a glance and can warn of impending
slowdowns due to congestion or other error conditions.
1

Choose Statistics → WAN Load by DLCI.

2

Press Start to begin capturing load data.

84 WAN Load by DLCI
Chapter 5 Using Observer with a WAN Probe

rev. 1

Figure 55 WAN Load by DLCI

The WAN Load by DLCI mode can be viewed as a dial, graph, or list
display. Except for list view, there are no setup options for WAN Load
by DLCI mode. Every view includes a dropdown box that lets you
select which DLCI you want to monitor.
Figure 56 WAN Load by DLCI Dial View

The WAN Load by DLCI mode in dial view shows transfer rate, CRC
error rate, FECN/BECN frame rates graphed on dial meters.
For encapsulations that do not use DLCI (such as X.25), the correct
address value is shown even though it is still labeled DLCI.

rev. 1

WAN Load by DLCI 85
Chapter 5 Using Observer with a WAN Probe

Figure 57 WAN Load by DLCI Graph View

The WAN Load display in graph view shows these same statistics
(transfer rate, CRC error rate, and FECN/BECN frame rates) as
superimposed spike meters. The Committed Information Rate (CIR)
is also shown, allowing you to view the network activity against the
baseline performance you have contracted to receive from your WAN
service provider
You can select line, point, or bar-style meter, and the colors for each
statistic by right-clicking on the chart. The dropdown menus at the
top of the display let you select what DLCIs to view, and how the
chart should be scaled (linearly, logarithmically, or auto-scale). For
linear scales, you can also set the CIR or the line rate as the maximum
value for the chart.

WAN Top Talkers
Just as in standard Observer, Top Talkers shows the IP and MAC
address of stations on your network sorted by volume of traffic
generated and received. In WAN Observer, the MAC Address tab
shows DLCIs sorted by volume of traffic. Also, the sorting and
charting statistical criteria (such as percentage of packets, packets per

86 WAN Top Talkers
Chapter 5 Using Observer with a WAN Probe

rev. 1

second, etc.) that apply to WAN is a subset of those available for
standard network analysis. For encapsulations that do not use DLCI
(such as X.25), the correct address value is shown even though it is
still labeled DLCI.
1

Choose Statistics → Top Talkers Statistics.

2

Press Start to begin capturing load data.
Figure 58 WAN Top Talkers

TIP !

If you are looking to identify additional top talkers beyond the
DLCI, using Ethernet Top Talkers may be more beneficial for
you.

WAN Filtering
In addition to the standard Observer packet filtering rules (station
address, pattern matching, etc.), there are two WAN-specific filtering
rules available for use with WAN probes:
Q

Q

DLCI Address, which lets you enter the number of the DLCI
address you wish to include or exclude.
WAN Conditions, which let you include or exclude frames
based on flow direction, forward and backward congestion,
and discard eligibility.

To create a WAN filter rule:

rev. 1

1

Choose Actions →Filter Setup for Selected Probe.

2

Select an existing filter or click New Filter to create your own.
See the filtering information in the Observer manual for full
details about creating a custom filter from scratch.
WAN Filtering 87
Chapter 5 Using Observer with a WAN Probe

Figure 59 Active Filters

Triggers and Alarms
WAN Observer adds WAN-related criteria to the standard Triggers
and Alarms mode.
1

Click the Alarm Settings button located in the lower left corner of
Observer’s main window.
Figure 60 Alarm Settings

A dialog appears that allows you to select the probe or probes for
which you want to set alarms.
2

Check the probes you wish to set.

3

Select an probe for which you want to set alarms and then click
the Selected Instance Alarm Settings button. Figure 61 appears.

88 Triggers and Alarms
Chapter 5 Using Observer with a WAN Probe

rev. 1

Figure 61 Probe Alarm Settings

4

Select the alarms you want set.

5

Click the Triggers tab to set the criteria by which the alarms will
be triggered.
Figure 62 Triggers tab

rev. 1

Triggers and Alarms 89
Chapter 5 Using Observer with a WAN Probe

Most WAN alarms can be set on the DTE or DCE side or both.
The Committed Information Rate displayed is that which you set
in Discover Network Names mode. See “Setting the Committed
Information Rate (CIR) for a DLCI” on page 80.
6

Click the Actions tab to define actions to launch if an alarm is
triggered. You can log messages, send e-mail, or even send a pager
alarm.

90 Triggers and Alarms
Chapter 5 Using Observer with a WAN Probe

rev. 1

Chapter 6

Forensic Analysis using Snort

91
rev. 1

Chapter 6 Forensic Analysis using Snort

Forensic Analysis, exclusive to the GigaStor version of Observer, is a
powerful tool for scanning high-volume packet captures for intrusion
signatures and other traffic patterns that can be specified using the
familiar Snort rule syntax. You can obtain the rules from
www.snort.org, or, if you know the Snort rule syntax, you can write
your own rules.
Snort began as an open source network intrusion detection system
(NIDS). Snort’s rule definition language is the standard way to specify
packet filters aimed at sensing intrusion attempts.
Snort rules (or Snort-style rules) imported into Observer operate
much like Observer’s Expert conditions, telling Observer how to
examine each packet to determine whether it matches specified
criteria, triggering an alert when the criteria is met. They differ from
Expert conditions in that they only operate post-capture, and the rules
themselves are text files imported into Observer.
NOTE:

Only rules with alert actions are imported. Rules with log,
activate, dynamic, or any actions other than alert are simply
ignored. Except for RULE_PATH, variable declarations (Snort
var statements) are imported. Rule classifications (config
classification) are imported, but any other config statements
are ignored. Another difference is that Observer, unlike Snort,
supports IPv6 addressing.

After you import the rules into Observer you are able to enable and
disable rules and groups of rules by their classification as needed.

Starting Forensic Analysis using Snort rules
Forensics profiles provide a mechanism to define and load different
pairings of settings and rules profiles. Settings profiles define preprocessor settings that let you tune performance; rules profiles define
which forensic rules are to be processed during analysis.
Observer lets you configure preprocessor settings to tune
performance, and to perform specialized processing designed to catch
threats against particular target operating systems and web servers.
Because Observer performs signature matching on existing captures
rather than in real time, its preprocessor configuration differs from
92 Starting Forensic Analysis using Snort rules
Chapter 6 Forensic Analysis using Snort

rev. 1

that of native Snort. When you import a set of Snort rules that
includes configuration settings, Observer imports rules classifications,
but uses its own defaults for the preprocessor settings.
NOTE:

There is a difference between enabling the preprocessor and
enabling logs for the preprocessor. For example, you can
enable IP defragmentation with or without logging. Without
logging, IP fragments are simply reassembled; only time-out
or maximum limit reached messages are noted in the
Forensics Log and in the Forensic Analysis Summary window.
If logging is enabled, all reassembly activity is displayed in the
Forensics Log (but not displayed in the Forensic Analysis
Summary).

Forensics analysis is available from both the Decode/Analysis window
displayed when you load a saved capture buffer locally from GigaStor,
and also from the GigaStor control panel. In either case, if you have
not yet imported any rules, or if you wish to add or modify rules, click
Edit to display the Forensic Settings dialog.
Q

From the Decode/Analysis Display: After loading a
previously-saved capture buffer, click the Forensics tab. The
Select Forensics Analysis dialog is displayed:

Figure 63 Select Forensic Analysis Profile dialog

Q

rev. 1

From the GigaStor Control Panel: Select the time window
you wish to analyze, then click Analyze. At the bottom of the
GigaStor Analysis Options dialog you can select or edit a
Forensics profile. This is described in detail in “Creating a
forensic analysis profile from the GigaStor control panel” on
page 94.

Starting Forensic Analysis using Snort rules 93
Chapter 6 Forensic Analysis using Snort

Figure 64 GigaStor Analysis Options - Forensic Analysis section

If you already have a forensic analysis profile, you choose the profile
from the Profile list (Figure 64) and click OK. For more information
about the analysis output, see:
Q

“About Forensic Analysis tab” on page 98

Q

“About the Forensic Analysis Log tab” on page 99

Creating a forensic analysis profile from the GigaStor control panel
1

Click the Forensics Analysis tab on the far right of the screen.
Figure 65 Forensic Analysis tab

2

Click the Analyze button at the top of the screen. The GigaStor
Analysis Options dialog opens.

94 Starting Forensic Analysis using Snort rules
Chapter 6 Forensic Analysis using Snort

rev. 1

Figure 66 GigaStor Analysis Options

3

Select the profile that you want or click Edit.

4

Click the Settings Profile Edit button to view and define the fields
as you need. The fields are described in full in “Forensic Analysis
Profile Settings tab” on page 100.
Figure 67 Forensic Settings

rev. 1

Starting Forensic Analysis using Snort rules 95
Chapter 6 Forensic Analysis using Snort

If this is the first time forensic analysis has been run, you must
import some rules.
5

Click the Import Snort Files button to display a file selection
dialog. Browse to the directory where the rules you wish to
import are located and select them. You can select multiple files
using either CTRL-clicks or by simply dragging the cursor across
the files you wish to select. If you do not yet have the Snort rules,
see “Rules tab” on page 106.

6

Click OK when you are done selecting files.
Observer displays a progress bar and then an import summary
showing the results of the import. Because Observer’s forensic
analysis omits support for rule types and options not relevant to a
post-capture system, the import summary will probably list a few
unrecognized options and rule types. This is normal, and unless
you are debugging rules that you wrote yourself, can be ignored.

7

Close the Import Summary Window.

8

Click the Edit button to the right of the Rules profile dropdown
menu.
Figure 68 Forensic Settings

The Rule Settings dialog is displayed (Figure 69). The top portion
of the window lists the rules that were imported, grouped in a
tree with branches that correspond to the files that were
imported.
96 Starting Forensic Analysis using Snort rules
Chapter 6 Forensic Analysis using Snort

rev. 1

Figure 69 Rules tab

9

Select the boxes next to the rules you want to enable. The rightclick menu has options to enable/disable all rules, and to show the
actual Snort rule that was imported. It also lets you jump to webbased threat references such as bugtraq for further information
about the alert.
Rule classifications offer another level of control. Check the
“Rules must also match rule classifications” box to display a list of
defined rule classifications. Classifications are defined at import
time by parsing the Snort config classification statements
encountered in the rule set. Rules are assigned a classification in
the rule statement’s classtype option.
Select the rule classification(s) you want to enable. If classification
matching is enabled, a rule and its classification must both be
enabled for that rule to be processed. For example, suppose you
want to enable all policy violation rules: simply right-click on the
rule list, choose Enable all rules, and then enable the policy
violation classification.

rev. 1

Starting Forensic Analysis using Snort rules 97
Chapter 6 Forensic Analysis using Snort

10 Click OK to close the Forensic Analysis Profile dialog. Click OK
again to close the Forensic Settings dialog. Click OK to close the
GigaStor Analysis Options dialog.
Observer applies the rules and filters to the capture data and
displays the results in the Forensics Summary tab. A new tab is
also opened that contains the decode. For details about the tabs,
see:
Q

“About Forensic Analysis tab” on page 98

Q

“About the Forensic Analysis Log tab” on page 99

About Forensic Analysis tab
This display summarizes alerts and preprocessor events in a navigable
tree.
Figure 70 Forensic Summary

TIP ! P REPROCESSOR
M AXIMUMS

It is important to examine the preprocessor results to ensure
that time-outs and other maximum value exceeded conditions
haven’t compromised the analysis. In Figure 70, both the IP
Flow and TCP Stream Reassembly preprocessors have timed
out on hundreds of flows and streams. If you see similar

98 Starting Forensic Analysis using Snort rules
Chapter 6 Forensic Analysis using Snort

rev. 1

results, you may want to adjust preprocessor settings to
eliminate these conditions. Intruders often attempt to exceed
the limitations of forensic analysis to hide malicious content.

The right-click menu lets you examine the rule that triggered the alert
(if applicable). It also lets you jump to web-based threat references
such as bugtraq for further information about the alert. These
references must be coded into the Snort rule to be available from the
right-click menu.

About the Forensic Analysis Log tab
The Forensic Analysis Log comprehensively lists all rule alerts and
preprocessor events in a table, letting you sort individual occurrences
by priority, classification, rule ID, or any other column heading. Just
click on the column heading to sort the alerts by the given criteria.
Figure 71 Forensic Analysis Log tab

The right-click menu lets you examine the rule that triggered the alert
(if applicable). It also lets you jump to web-based threat references
such as bugtraq for further information about the alert. These
references must be coded into the Snort rule to be available from the

rev. 1

Starting Forensic Analysis using Snort rules 99
Chapter 6 Forensic Analysis using Snort

right-click menu. You can also jump to the Decode display of the
packet that triggered the alert.

Forensic Analysis Profile field descriptions
This section describes in detail the fields on the Settings and Rules tab.
See:
Q

“Forensic Analysis Profile Settings tab” on page 100

Q

“Rules tab” on page 106

Forensic Analysis Profile Settings tab
Figure 72 Forensic Analysis Profile Settings tab

Table 8 describes the fields in the Forensic Analysis Profile Settings
tab.

100 Forensic Analysis Profile field descriptions
Chapter 6 Forensic Analysis using Snort

rev. 1

Table 8 Forensic Analysis Profile Settings tab
Field

Description

Settings Profile

Settings Profiles provide a mechanism to save and load different preprocessor
settings, and share them with other Observer consoles.

IP Flow

Packets belong to the same IP flow if they share the same layer 3 protocol, and also
share the same source and destination addresses and ports. If this box is checked,
forensic analysis identifies IP flows (also known as conversations), allowing Snort
rules to isolate packets by direction and connection state via the flow option. If this
pre-processor is disabled, flow keywords are ignored, but the rest of the rule is
processed. The remaining settings allow you to throttle flow analysis by limiting the
number of flows tracked, and by decreasing the time window within which a flow is
considered active.

IP Defragmentation

Some types of attacks use packet fragmentation to escape detection. Enabling this
preprocessor causes forensic analysis to identify and reconstruct fragmented
packets based on the specified fragment reassembly policy. Rules are then run
against the reconstructed packets during forensic analysis. The fragment
reassembly policy mimics the behavior of various operating systems in what to do
when ambiguous fragments are received. Choose the policy to match the OS of the
server (or servers) being monitored (see the table below). If the buffer contains
traffic targeting hosts with different operating systems, use post-filtering to isolate
the traffic before forensic analysis so that you can apply the correct policy.
Defragmentation Policy is:
BSD = AIX, FreeBSD, HP-UX B.10.20, IRIX, IRIX64, NCD Thin Clients, OpenVMS, OS/2,
OSF1, SunOS 4.1.4, Tru64 Unix, VAX/VMS
Last data in = Cisco IOS
BSD-right = HP JetDirect (printer)
First data in = HP-UX 11.00, MacOS, SunOS 5.5.1 through 5.8
Linux = Linux, OpenBSD
Solaris = Solaris
Windows = Windows (95/98/NT4/W2K/XP)
Refer to www.snort.org for more detailed version-specific information. The
remaining options allow you to enable logging of alerts and reconstruction
progress, limit the number of active packet fragments to track, and change the
length of fragment inactivity that causes the fragment to be dropped from analysis.

TCP Stream
Reassembly

Another IDS evasion technique is to fragment the attack across multiple TCP
segments. Because hackers know that IDS systems attempt to reconstruct TCP
streams, they use a number of techniques to confuse the IDS so that it reconstructs
an incorrect stream (in other words, the IDS processes the stream differently from
that of the intended target). As with IP fragmentation, forensic analysis must
configured to mimic how the host processes ambiguous and overlapping TCP
segments, and the topology between attacker and target to accurately reassemble
the same stream that landed on the target. Re-assembly options are described
below:

rev. 1

Forensic Analysis Profile field descriptions 101
Chapter 6 Forensic Analysis using Snort

Table 8 Forensic Analysis Profile Settings tab (Continued)
Field

Description

TCP Stream
Reassembly
(Continued)

Q

Log preprocessor events—Checking this box causes forensic analysis to display
all activity generated by the TCP stream assembly preprocessor to the log.

Q

Maximum active TCP streams tracked—If this value is set too high given the size
of the buffer being analyzed, performance can suffer because of memory
consumption. If this value is set too low, forensic analysis can be susceptible to
denial of service attacks upon the IDS itself (i.e., the attack on the target is carried
out after the IDS has used up its simultaneous sessions allocation).

Q

Drop TCP streams inactive for this duration—A TCP session is dropped from
analysis as soon as it has been closed by an RST message or FIN handshake, or
after the time-out threshold for inactivity has been reached. Exercise caution
when adjusting the time-out, because hackers can use TCP tear-down policies
(and the differences between how analyzers handle inactivity vs. various
operating systems) to evade detection.

Q

TTL delta alert limit—Some attackers depend on knowledge of the target
system’s location relative to the IDS to send different streams of packets to each
by manipulating TTL (Time To Live) values. Any large swing in Time To Live (TTL)
values within a stream segment can be evidence of this kind of evasion attempt.
Set the value too high, and analysis will miss these attempts. Setting the value
too low can result in excessive false positives.

Q

Overlapping packet alert threshold—The reassembly preprocessor will generate
an alert when more than this number of packets within a stream have
overlapping sequence numbers.

Q

Process only established streams—Check this box if you want analysis to
recognize streams established during the given packet capture.

Q

Reconstruct Client to Server streams—Check this box to have analysis actually
reconstruct streams received by servers.

Q

Reconstruct Server to Client streams—Check this box to have analysis actually
reconstruct streams received by clients.

Q

Overlap method—Different operating systems handle overlapping packets
using one of these methods. Choose one to match the method of the systems
being monitored.

102 Forensic Analysis Profile field descriptions
Chapter 6 Forensic Analysis using Snort

rev. 1

Table 8 Forensic Analysis Profile Settings tab (Continued)
Field

Description

TCP Stream
Reassembly
(Continued)

Q

Reassembly error action—Discard and flush writes the reassembled stream for
analysis, excluding the packet that caused the error. Insert and flush writes the
reassembled stream, but includes the packet that caused the error. Insert no
flush includes the error-causing packet and continues stream reassembly.

Q

Reassembled packet size threshold range—Some evasion strategies attempt to
evade detection by fragmenting the TCP header across multiple packets.
Reassembling the stream in packets of uniform size makes this easier for
attackers to slip traffic past the rules, so forensic analysis reassembles the stream
using random packet sizes. Here you can set the upper and lower limits on the
size of these packets.

Q

Reassembled packet size seed value—Changing the seed value will cause
forensic analysis to use a different pattern of packet sizes for stream reassembly.
Running the analysis with a different seed value can catch signature matches
that would otherwise escape detection.

Q

Port List—Enabling the Port List option limits analysis to (or excludes from
analysis) the given port numbers.

HTTP URI
Normalization

rev. 1

Many HTTP-based attacks attempt to evade detection by encoding URI strings in
UTF-8 or Microsoft %u notation for specifying Unicode characters. This preprocessor
includes options to circumvent the most common evasion techniques. To match
patterns against the normalized URIs rather than the unconverted strings captured
from the wire, the VRT Rules use the uricontent option, which depends on this
preprocessor. Without normalization, you would have to include signatures for the
pattern in all possible formats (using the content option), rather than in one
canonical version.
Q

Log preprocessor events—Checking this box causes forensic analysis to save any
alerts generated by the HTTP preprocessor to the log, but not the Forensic
Summary Window.

Q

Maximum directory segment size—Specifies the maximum length of a directory
segment (i.e., the number of characters allowed between slashes). If a URI
directory is larger than this, an alert is generated. 200 characters is reasonable
cutoff point to start with. This should limit the alerts to IDS evasions.

Q

Unicode Code Page—Specify the appropriate country code page for the traffic
being monitored.

Q

Normalize ASCII percent encodings—This option must be enabled for the rest of
the options to work. The second check box allows you to enable logging when
such encoding is encountered during preprocessing. Because such encoding is
considered standard, logging occurrences of this is not recommended.

Forensic Analysis Profile field descriptions 103
Chapter 6 Forensic Analysis using Snort

Table 8 Forensic Analysis Profile Settings tab (Continued)
Field

Description

HTTP URI
Normalization
(Continued)

Q

Normalize percent-U encodings—Convert Microsoft-style %u-encoded
characters to standard format. The second check box allows you to enable
logging when such encoding is encountered during preprocessing. Because
such encoding is considered non-standard (and a common hacker trick), logging
occurrences of this is recommended.

Q

Normalize UTF-8 encodings—Convert UTF-8 encoded characters to standard
format. The second check box allows you to enable logging when such
encoding is encountered during preprocessing. Because Apache uses this
standard, enable this option when monitoring Apache servers. Although you
might be interested in logging UTF-8 encoded URIs, doing so can result in a lot
of noise because this type of encoding is common.

Q

Lookup Unicode in code page—Enables Unicode codepoint mapping during
pre-processing to handle non-ASCII codepoints that the IIS server accepts.

Q

Normalize double encodings— This option mimics IIS behavior that intruders
can use to launch insertion attacks. Normalize bare binary non ASCII
encodings—This an IIS feature that uses non-ASCII characters as valid values
when decoding UTF-8 values. As this is non-standard, logging this type of
encoding is recommended.

Q

Normalize directory traversal—Directory traversal attacks attempt to access
unauthorized directories and commands on a web server or application by using
the /./ and /../ syntax. This preprocessor removes directory traversals and selfreferential directories. You may want to disable logging for occurrences of this,
as many web pages and applications use directory traversals to reference
content.

Q

Normalize multiple slashes to one—Another directory traversal strategy is to
attempt to confuse the web server with excessive multiple slashes.

Q

Normalize Backslash—This option emulates IIS treatment of backslashes (i.e.,
converts them to forward slashes).

104 Forensic Analysis Profile field descriptions
Chapter 6 Forensic Analysis using Snort

rev. 1

Table 8 Forensic Analysis Profile Settings tab (Continued)
Field

Description

ARP Inspection

Ethernet uses Address Resolution Protocol (ARP) to map IP addresses to a particular
machine (MAC) addresses. Rather than continuously broadcasting the map to all
devices on the segment, each device maintains its own copy, called the ARP cache,
which is updated whenever the device receives an ARP Reply. Hackers use cache
poisoning to launch man-in-the-middle and denial of service (DoS) attacks. The ARP
inspection preprocessor examines ARP traffic for malicious forgeries (ARP spoofing)
and the traffic resulting from these types of attacks.

Telnet Normalization

Variable Name

rev. 1

Q

Log preprocessor events—Checking this box causes forensic analysis to save any
alerts generated by the ARP Inspection preprocessor to the log, but not the
Forensic Summary Window.

Q

Report non-broadcast requests—Non-broadcast ARP traffic can be evidence of
malicious intent. Once scenario is the hacker attempting to convince a target
computer that the hacker’s computer is a router, thus allowing the hacker to
monitor all traffic from the target. However, some devices (such as printers) use
non-broadcast ARP requests as part of normal operation. Start by checking the
box to detect such traffic; disable the option only if analysis detects false
positives.

Hackers may attempt to evade detection by inserting control characters into Telnet
and FTP commands aimed at a target. This pre-processor strips these codes, thus
normalizing all such traffic before subsequent forensic rules are applied.
Q

Log preprocessor events—Checking this box causes forensic analysis to save any
alerts generated by the Telnet Normalization preprocessor to the log, but not
the Forensic Summary Window.

Q

Port List—Lets you specify a list of ports to include or exclude from Telnet preprocessing. The default settings are appropriate for most networks.

A scrollable window located below the preprocessor settings lists the variables that
were imported along with the Snort rules. Variables are referenced by the rules to
specify local and remote network ranges, and common server IP addresses and
ports. You can edit variable definitions by double-clicking on the variable you want
to edit.
The VRT Rule Set variable settings (and those of most publicly-distributed rule sets)
will work on any network without modification, but you can dramatically improve
performance by customizing these variables to match the network being
monitored. For example, the VRT rules define HTTP servers as any, which results in
much unnecessary processing at runtime.
Address variables can reference another variable, or specify an IP address or class,
or a series of either. Note that unlike native Snort, Observer can process IPv6
addresses.
Port variables can reference another variable, or specify a port or a range of ports.
To change a variable, simply double-click the entry. The Edit Forensic Variable
dialog shows a number of examples of each type of variable which you can use as a
template when changing values of address and port variables.

Forensic Analysis Profile field descriptions 105
Chapter 6 Forensic Analysis using Snort

Rules tab
The web site www.snort.org provides Snort rule documentation, and
downloadable rule sets. There are three sets of rules available at
www.snort.org: Community Rules (which are available to anyone with
a web browser), and three versions of the Vulnerability Response
Team (VRT) Certified Rule Set. The most recent rule updates are
available to paid subscribers only; non-paying registered users have
access to the VRT Rule Set 30 days after subscribers, and unregistered
users have access to snapshots of the rule sets that are distributed with
Snort releases. All of the rule sets are distributed as tar archives;
download the desired rule set and extract the archive to a directory
that is accessible to the Observer console.
Although it is recommended that you eventually register for at least
the Certified Rule Set, here are the steps for obtaining the Snort
release snapshot distribution. If you need archive software that can
extract tar files, www.7-zip.org has a free, open source utility that
handles most of the popular archive formats, including tar.
1

Go to www.snort.org. Click the Rules link on the left side banner.
This displays the VRT rules main page.

2

Click the Download Rules link located on the right side banner.

3

Click the link to Sourcefire VRT Certified Rules (unregistered
user release).

4

Click the Download button for the most recent unregistered user
release. Save the file (which should have a name something like
snortrules-pr-2.4.tar.gz).

5

Extract the rules directory from the archive you downloaded to a
directory that is accessible to the GigaStor.

106 Forensic Analysis Profile field descriptions
Chapter 6 Forensic Analysis using Snort

rev. 1

Chapter 7

Observer on the GigaStor

107
rev. 1

Chapter 7 Observer on the GigaStor

Using the Observer console locally on the GigaStor
Depending on how you want or need to use Observer it can be either
a graphic console to help you analyze your network data or it can be a
probe to capture data and to which other Observer consoles can
connect. Observer cannot simultaneously be a console and a probe.
In some situations you may want to run Observer locally on your
GigaStor instead of using a separate system. This is not the default
behavior for a GigaStor. This section describes how to stop the probe
that runs as a Windows service and launch Observer.
On the local GigaStor system
1

Right-click the Probe Service Configuration Applet in the system
tray and choose Open Probe Configuration.

Figure 73 Probe Service Configuration Applet

2

The Probe Administration window opens. Click the Probe
Options tab (Figure 74).

108 Using the Observer console locally on the GigaStor
Chapter 7 Observer on the GigaStor

rev. 1

Figure 74 Probe Options

3

In the Service Settings section, clear the “Run Probe as a Windows
Service” option and click OK. This uninstalls the Network
Instruments Expert Probe service from Windows.

4

Click Start →Programs →Observer →Observer. The Network
Instruments Expert Probe window opens.
Figure 75 Expert Probe interface

rev. 1

Using the Observer console locally on the GigaStor 109
Chapter 7 Observer on the GigaStor

5

Choose Options →Switch between Observer and Expert Probe
Interface.
The Choose Program Interface window opens.

TIP ! S WITCHING
E XPERT
P ROBE

BACK TO

6

Choose Observer and click OK. You must close Observer and
restart it to switch into the console interface. Click OK on the
message dialog.

7

Click Start →Programs →Observer →Observer to open the
console interface.
In Observer, choose View → Switch between Observer and
Expert Probe Interface.
After the Expert Probe interface is open, choose Options →
Probe Options to select the Run Probe as Windows Service
option. You must manually start Network Instruments Expert
Probe from the Windows Service Control Manger. It may take
a moment before the service starts. You may need to restart
the GigaStor for the setting changes to fully set.

110 Using the Observer console locally on the GigaStor
Chapter 7 Observer on the GigaStor

rev. 1

Chapter 8

Probe Instances

111
rev. 1

Chapter 8 Probe Instances

What is a probe instance?
TIP !

For instructions on setting up a probe instance, see “Probe
administration” on page 24.

Observer uses probes to capture network data. In some cases you may
want or need more than one probe in a specific location. You can
achieve that through probe instances. A probe instance provides you
the ability to look at multiple network interfaces or to publish to
multiple Observer consoles.
Observer has only one kind of probe instance: the passive probe
instance. If you have a GigaStor you have an additional probe instance
type available to you: the active probe instance.
Table 9 compares the features of active and passive probe instances.
Table 9 Active probe instance compared to passive
GigaStor
Active

GigaStor
Passive

Observer

Start packet capture
Stop packet capture
Start GigaStor packet capture
Schedule packet capture
Change directories where data is stored
Able to set permissions
Able to redirect to different console, etc.
Better suited for troubleshooting
Better suited for data capture

A passive probe instance captures packets to RAM and allows you to
do reactive analysis or look at real-time statistics for troubleshooting.
The passive probe instance binds to whichever network adapter you
want. You can change whatever adapter a passive probe instance is
bound to without affecting any active probe instance.
CAUTION : PASSIVE
PROBE INSTANCE AND
THE GEN2 CARD
112 What is a probe instance?
Chapter 8 Probe Instances

With a GigaStor you have the option of which NIC to bind
the passive probe instance. Do not bind any passive probe

rev. 1

instances to the Gen2 adapter if at all possible. A copy of all
packets are sent from the adapter to every passive probe
instance attached to it. If you have several passive probe
instances attached to the Gen2 adapter, the Gen2’s
performance is significantly affected. Instead attach the
passive probe instances to either a 10/100/1000 adapter or to
a non-existent one.

If you have a passive probe instance connected to a GigaStor, it can
mine data that has already been written to the RAID disk by an active
probe instance. There should be one passive probe instance for each
simultaneous Observer user on a GigaStor. By using a passive probe
instance instead of an active probe instance only one copy of data is
being captured an written to disk, which reduces the processor load
and the required storage space. For troubleshooting and most uses in
Observer passive probe instances are appropriate.
By default a passive probe instance uses 12 MB of RAM. You can
reserve more memory for passive probe instances if you wish.
An active probe instance on a GigaStor captures network traffic and
writes it to the RAID array. A active probe instance should have as
large of a RAM buffer as possible to cushion between the network
throughput rate and the array write rate.
Like a passive probe instance, it can also be used to mine data from
the hard disk, however a passive instance is better suited for the task.
An active probe instance cannot start a packet capture while the
GigaStor Control Panel is running.
TIP ! A CTIVE PROBE
INSTANCE BEST

Q

PRACTICES
Q

Q

Q

rev. 1

Only one active probe instance per GigaStor.
Set scheduling to Always for the active probe instance so that
it is constantly capturing and writing data. Use a passive
probe instance to mine the data.
Do not pre-filter, unless you know exactly what you want to
capture. Of course, if something occurs outside the bounds of
the filter, you will not have the data in the GigaStor.
Do not allow remote users access to the active probe instance.

What is a probe instance? 113
Chapter 8 Probe Instances

NOTE:

By default there is one active probe instance for GigaStor. It
binds to the network adapter and its ports. If you have a
specific need to separate the adapter’s ports and monitor
them separately, you can do so through passive probe
instances or you can create separate virtual adapters. See
“Configuring virtual adapters on the Gen2 card” on page 116.

Figure 76 shows how one active probe instance captures and writes to
the GigaStor RAID. Passive probe instances 1 and 2 mine data from
the RAID array. As a best practice the passive probe instances are
bound to the slowest network adapter in the GigaStor.
Additionally, passive probe instance 3 and 4 each are capturing
packets separate from each other and separate from the active probe
instance. However, since they are also bound to the same adapter as
the active probe instance, they are capturing the same data as the
active probe instance.
Figure 76 GigaStor capture and packet capture through probe instances
Virtual
Adapter

1

GigaStor capture

m

DCE

2
DTE

3
DCE

4

2

DTE

Passive
Instance
1

pac
ket
cap
tur
e
pac
ket
cap
tur
e

g
inin

RAID

m in
in g

Active
Instance

1

Passive
Instance
2

RAM
Passive
Instance
3

RAM
Passive
Instance
4

Slowest
Adapter

114 What is a probe instance?
Chapter 8 Probe Instances

rev. 1

Chapter 9

Gen2 Capture Card

115
rev. 1

Chapter 9 Gen2 Capture Card

The Gen2 card is designed and manufactured by Network
Instruments and is optimized for the GigaStor. The Gen2 card comes
in two, four, or eight port models.
This section describes
Q

Q
Q

“Swapping the Gen2 card’s SFP or XFP interfaces” on
page 116
“Configuring virtual adapters on the Gen2 card” on page 116
“Viewing the Gen2 card’s properties and finding the board’s
ID” on page 120

Swapping the Gen2 card’s SFP or XFP interfaces
To connect the probe to a monitoring interface (TAP or SPAN/mirror)
different from that shipped with the unit, simply obtain the necessary
SFP for your application, remove the installed SFPs, and insert the
desired interface.
The SFPs can be hot-swapped, but you should disconnect any cables
before changing the SFP modules. As with any electronic components,
you should follow electrostatic discharge precautions (i.e., use a
grounding strap or touch the chassis power supply before handling
SFPs) to avoid damaging components. In addition, you should be
careful to avoid exposure to laser radiation from optical components
by keeping the dust plugs installed until you are ready to install cables.

Configuring virtual adapters on the Gen2 card
NOTE:

Only GigaStor’s equipped for 10 Gigabit Ethernet, Gigabit
Ethernet, and Fibre Channel use a Gen2 capture card.

By default Observer recognizes a Gen2 capture card as a single
adapter, regardless of how many ports are present. Sometimes this is
desirable (as when monitoring a trunk that consists of multiple links),
but for many applications it is more convenient for Observer to
recognize a subset of Gen2 ports as a single adapter. For example,
suppose you are deploying an 8-port Gen2 as follows:

116 Swapping the Gen2 card’s SFP or XFP interfaces
Chapter 9 Gen2 Capture Card

rev. 1

Q
Q

Ports 1-4 are monitoring a collection of trunked links
The remaining ports are each connected to the SPAN (or
mirror) port on a switch

In this scenario, it makes sense for Observer to view Ports 1-4 as a
single data stream and to separate each of the four remaining ports
into separate data streams.
Virtual adapters are a convenient way to accomplish this separation in
real time, rather than depending on filters to sort through the traffic
post-capture. A physical port cannot belong to more than one virtual
adapter.
To define a subset of Gen2 ports as a single virtual adapter,
1

Right-click the Gen2-equipped probe from Observer’s probe list
and choose Probe or Device Properties from the menu.You can tell
the probe is a GigaStor probe because (Gigabit) appears after the
probe name (Figure 77).
Figure 77 GigaStor probe

2

rev. 1

Click the Virtual Adapters tab and click Edit Adapter. By default
all of the ports are assigned to the adapter. You must remove ports
if you want to have multiple virtual adapters. See Figure 23 for a
diagram of the physical ports assignments.

Configuring virtual adapters on the Gen2 card 117
Chapter 9 Gen2 Capture Card

Figure 78 Assign Port to Virtual Adapter: Default view

3

Select the ports to remove and click Remove. This places them in
the Available Ports list.

4

Change the name of the adapter to something meaningful to you
and click OK (Figure 79).

Figure 79 Assign Ports to Virtual Adapter: Trunk

5

Click New Adapter. The Assign Ports to Virtual Adapter window
opens.

6

Type a name in the Adapter Name box.

7

Select the ports you want to assign to this virtual adapter from the
Available Ports list and click OK.

8

Select the port and click Edit Port. Type a useful description and
click OK. This description appears in the GigaStor Control Panel
in Observer.

118 Configuring virtual adapters on the Gen2 card
Chapter 9 Gen2 Capture Card

rev. 1

Figure 80 Edit Port Description

9

Repeat step 5 through step 8 until you have created all of your
virtual adapters and given descriptions to your ports. The adapters
appear in the list of adapters presented when you create a probe
instance. This allows you to bind the probe instance to a virtual
adapter.
Figure 81 shows the example of the trunk with four ports assigned
to it and four more adapters each with its own port.
Figure 81 Virtual Adapters tab

For each virtual adapter you must create an active probe instance and
bind the virtual adapter to that probe instance. By default, new virtual
adapters are not bound to any probe instance, so no data is collected
on those ports until assigned to a probe instance.

rev. 1

Configuring virtual adapters on the Gen2 card 119
Chapter 9 Gen2 Capture Card

10 Right-click the GigaStor probe and choose Administer Selected
Probe from the menu. Log in to the probe.
11 Click the GigaStor Instances tab along the bottom.
12 For each virtual adapter listed as a passive probe instance that you
want to promote to an active probe instance, select it, right click
and choose Make Instance Active.
Figure 82 Make Instance Active

13 A message appears with information about the change. Click Yes
to accept the changes.
Your virtual adapters are now configured.

Viewing the Gen2 card’s properties and finding the
board’s ID
To retrieve the board’s ID or view the Gen2 card’s properties:
1

On the GigaStor system, choose Start → All Programs →
Accessories → Windows Explorer. Choose My Computer and
right-click and choose Manage. The Computer Management
window opens.

120 Viewing the Gen2 card’s properties and finding the board’s ID
Chapter 9 Gen2 Capture Card

rev. 1

2

In the tree on the left, select Device Manager.

3

In the tree on the right, expand Network Instruments Capture
Adapters (Figure 83).
Figure 83 Computer Management window

4

Choose Network Instruments Gen2 Gigabit Capture Adapter,
right-click and choose Properties. Click the Current State tab
(Figure 84).

Figure 84 Gen2 Card Properties – Current State tab

rev. 1

Viewing the Gen2 card’s properties and finding the board’s ID 121
Chapter 9 Gen2 Capture Card

This tab shows all active physical ports on the Gen2 card and the
board’s ID. The “Interrupt enabled” and “DMA enabled” lights are
light green when Observer is running and dark green when
Observer is not running.
CAUTION ADVANCED
SETTINGS TAB

Do not make any changes to the settings on the Advanced
Settings tab unless directed by the Support department! The
DMA buffer size and DMA copy size are optimized at the
factory for your specific motherboard and Gen2 card.

122 Viewing the Gen2 card’s properties and finding the board’s ID
Chapter 9 Gen2 Capture Card

rev. 1

Appendix A

TCP/IP ports, NAT, and VPN

123
rev. 1

Appendix A TCP/IP ports, NAT, and VPN

This section discusses the TCP/IP ports, NAT, and VPN.

TCP/IP ports
Observer and all Network Instruments probes use ports 25901 and
25903 to communicate. These ports are registered ports to Network
Instruments.
All Network Instruments probes initiate connection with Observer
using port 25901. Observer listens on port 25901. After a connection
is established all communication between Observer and the probes
occurs on port 25901, except probe redirection and administration,
which uses port 25903.
Figure 85 Port connections

Observer Console

Port 2
5
9
0
1

redirection
n request
request approved
p

Port
25903
25901

connection
on request
e
connection established

25901

Any Probe

NAT
If you use network address translation (NAT) in your environment,
you must make some configuration changes in Observer. Using the
TCP/IP port information in “TCP/IP ports” on page 124, you should
be able to set up the NAT properly.
If the probe is outside the network where Observer is running, you
must forward port 25901 from the probe’s address to the system
running Observer.
When redirecting the probe, you must specify the NAT outside IP
address instead of the address that Observer puts in automatically. By
default, Observer tries to use its local IP address, which the probe will
not be able to find. Select “Redirect to a specified IP address” in the
Redirecting Probe or Probe Instance dialog (Figure 86).
124 TCP/IP ports
Appendix A TCP/IP ports, NAT, and VPN

rev. 1

Figure 86 NAT

If the Observer is outside the network where the probe is running,
you must forward port 25903 from the Observer’s address. You must
use the NAT outside IP address as the probe’s IP address when trying
to redirect and/or administer the probe from Observer.

VPN
Using VPN is an easy way to get access to a probe on a remote LAN.
The most common configuration change is when redirecting the
probe. You must manually enter the Observer IP address. By default,
Observer will use the LAN IP address configured to Observer. You
must enter your VPN client’s IP address by selecting “Redirect to a
specified IP address” in the probe redirection dialog.
Select “Redirect to a specified IP address” in the Redirecting Probe or
Probe Instance dialog (Figure 86) and type the VPN client’s IP
address.

rev. 1

VPN 125
Appendix A TCP/IP ports, NAT, and VPN

126 VPN
Appendix A TCP/IP ports, NAT, and VPN

rev. 1

Appendix B

GigaStor, GigaStor Expandable, and
Expansion Unit Cases

127
rev. 1

Appendix B GigaStor, GigaStor Expandable, and Expansion Unit Cases

GigaStor
Figure 87 shows the front of the GigaStor.
Figure 87 GigaStor
A
13
9
5
1

14
10
6
2

15
11
7
3

B

C D E F GH I

16
12
8
4

!

13
9
5
1

14
10
6
2

15
11
7
3

16
12
8
4

!

1

1

2

A.
B.
C.
D.
E.
F.
G.
H.
I.

Individual Drive Activity
System Reset Button
Alarm Mute Button
Primary Drive Activity
Power LED
Warning Notice LED
LAN1 LED
LAN2 LED
Motherboard Power Button

2

Table 10 GigaStor LEDs and Buttons
LED/Button

Description

Individual Drive Activity

These LEDs blink whenever there is activity on the drive in the RAID array. The
lights are red when there is a problem with the drive, otherwise they are green.

System Reset Button

When pushed, the system resets.

Alarm Mute Button

When an error or warning is detected the LED blinks and an alarm sounds.
Pushing this button silences the alarm. This button is used in conjunction with
the Warning Notice LED.

Primary Drive Activity

This LED blinks whenever there is activity on the main drive. This drive is where
the operating system is installed.

Power LED

This LED is lit whenever the unit and motherboard are powered on and running.

Warning Notice LED

When the unit detects a problem such as a fan failure or excessively high
temperature, the alarm sounds and this LED blinks. Even if the alarm is silenced,
this LED will blink until the alarm condition is resolved.

LAN1 LED

Not used.

LAN2 LED

Not used.

Motherboard Power
Button

The motherboard button works only when the power button on the rear of the
GigaStor is on. Press to turn on the GigaStor. If you press and hold this button for
a few seconds, the unit will do a a hard shut down.

128 GigaStor
Appendix B GigaStor, GigaStor Expandable, and Expansion Unit Cases

rev. 1

GigaStor Expandable
Controller unit
Figure 88 GigaStor Expandable controller
Power Button
Reset Button
Power LED
Hard Drive Activity
Fan LED
Temperature LEDs
Fan/Temperature Alarm Reset

Table 11 GigaStor Expandable LEDs and Buttons
LED/Button

Description

Power Button

The power button works only when the power switch on the rear of the unit is
on. Press to turn on the GigaStor. If you press and hold this button for a few
seconds, the unit will do a a hard shut down.

Reset Button

When pressed, the unit will do a hard restart of the GigaStor Expandable.

Power LED

This LED is lit whenever the unit and motherboard are powered on and running.

Hard Drive Activity

This LED blinks whenever there is activity on the drive. This drive is where the
operating system is installed.

Fan LED

When green, the fan is operating as expected. If it is red, there is a problem with
the fan. The removable filter may need to be cleaned. Works in conjunction with
the Alarm button. Even if the alarm is silenced, this LED will blink until the alarm
condition is resolved.

Temperature LEDs

When lit green the unit’s temperature is within normal operating conditions. If it
is red, then the unit is too hot. Works in conjunction with the Alarm button. Even
if the alarm is silenced, this LED will blink until the alarm condition is resolved.

Fan/Temperature Alarm
Button

When pressed, it silences the on board alarm. Alarms may sound with the unit is
too hot or the fan has a problem. Even if the alarm is silenced, this LED will blink
until the alarm condition is resolved.

rev. 1

GigaStor Expandable 129
Appendix B GigaStor, GigaStor Expandable, and Expansion Unit Cases

Figure 89 shows the back of the GigaStor Expandable.
Figure 89 GigaStor Expandable rear view

Serial ATA Disk Interfaces (3)
only available on GigaStor Exandable
A

1

2

3

4

B

1

2

3

4

C

1

2

3

4

Power Supply
Gen2 Capture Card
On/Off
Keyboard and Monitor
10/100/1000 Ethernet

Expansion unit
Figure 90 Expansion unit
A

C

B

D

E

F

G
A.
B.
C.
D.
E.
F.
G.

A13
A9
A5
A1

A14
A10
A6
A2

A15
A11
A7
A3

Individual Drive Activity
Temperature Probe
Fan LED
Power LED
Reset Button
Alarm Button
Motherboard Power Button

A16
A12
A8
A4

130 GigaStor Expandable
Appendix B GigaStor, GigaStor Expandable, and Expansion Unit Cases

rev. 1

Table 12 Expansion Unit LEDs and Buttons
LED/Button

Description

Individual Drive Activity

These LEDs blink whenever there is activity on the drive in the RAID array. The
lights are red when there is a problem with the drive, otherwise they are green.

Temperature probe

When lit green the unit’s temperature is within normal operating conditions. If it
is red, then the unit is too hot. Works in conjunction with the Alarm button. Even
if the alarm is silenced, this LED will blink until the alarm condition is resolved.

Fan LED

When green, the fan is operating as expected. If it is red, there is a problem with
the fan. The removable filter may need to be cleaned. Works in conjunction with
the Alarm button. Even if the alarm is silenced, this LED will blink until the alarm
condition is resolved.

Power LED

This LED is lit whenever the unit and motherboard are powered on and running.

Reset Button

This button is flush with the case. When pressed, the unit will do a hard restart.

Alarm Button

This button is flush with the case. When pressed, it silences the on board alarm.
Alarms may sound with the unit is too hot or the fan has a problem. Even if the
alarm is silenced, this LED will blink until the alarm condition is resolved.

Motherboard Power
Button

The motherboard button works only when the power button on the rear of the
GigaStor is on. Press to turn on the expansion unit. If you press and hold this
button for a few seconds, the unit will do a a hard shut down.

Figure 91 shows the back of the expansion unit.
Figure 91 Expansion unit rear view

Serial ATA Disk Interface
A

1

2

3

4

Power Supply
On/Off

rev. 1

GigaStor Expandable 131
Appendix B GigaStor, GigaStor Expandable, and Expansion Unit Cases

132 GigaStor Expandable
Appendix B GigaStor, GigaStor Expandable, and Expansion Unit Cases

rev. 1

Appendix C

GigaStor Portable

133
rev. 1

Appendix C GigaStor Portable

The portable GigaStor offers full-duplex packet capture and analysis
at wire speed. Depending on which version you ordered, the system
includes everything you need to perform continuous, in-depth analysis
of one of the following topologies:
Q

Gigabit Ethernet

Q

10 Gigabit Ethernet

Q

Fibre Channel

Q

Wide Area Networks (WAN), in any of a number of different
encapsulations

The Portable Analysis Platform includes an internal probe that
provides access to the network to which it is connected. The internal
probe not only provides a point of visibility for the local Observer
console, but also for remote Observer consoles that have been given
administrative permission. In other words, the Portable Analysis
Platform can double as a secure, remote probe, which can be
indispensable for multi-site troubleshooting.
All Ethernet and Fibre Channel versions of the platform feature Small
Form-factor Portable (SFP or XFP) technology, allowing you to hotswap any SFP-compliant connectors into the system. This makes it
possible to use the same system to monitor different types of links as
needed without having to open the case to swap interface cards. For
example, you can easily convert the capture card from optical to
copper, allowing you to connect the system to different TAPs and
Switch Port Analyzer (SPAN) interfaces.

134
Appendix C GigaStor Portable

rev. 1

Figure 92 Portable Analysis Platform System Tour

CD/DVD R/W combo drive
and TAP bay
e t wo r k

instrum

e n t s. co

m

10

100

1000

A

Link

B A

Analyzer

B

w w w. n

Turn thumbscrews to
open port access door

Port layout varies
by topology

Your GigaStor includes a number of components. Take a moment
after unpacking the system to ensure that you received all the parts.
Q

A ruggedized “portable” PC system with Observer Suite
hardware interfaces and drivers for the relevant topology preinstalled:

135
rev. 1

Appendix C GigaStor Portable

Figure 93 Portable GigaStor

Gigabit and Fibre Channel systems have an appropriate copper or
optical nTAP installed in the drive bay on the right side of the system.
WAN system TAPs are shipped separately.

Running Observer passively
When analyzing a link using a TAP, Observer runs “passively.” Passive
operation guarantees that analysis will not affect the link; however, it
does have some implications when running Observer. Because there is
no link over which the system can transmit packets or frames, the
following features are unavailable:
Q

Traffic Generation

Q

Collision Test

Q

Replay Packet Capture

The Portable GigaStor includes a standard 10/100/1000 Ethernet
interface in addition to the WAN, Gigabit, or Fibre Channel
interface(s). The standard Ethernet interface allows you to use the
system on non-gigabit networks by simply connecting it to an
Ethernet hub or switch using a standard Ethernet cable. The TCP/IP
driver has been set to automatically obtain an IP address through the
136 Running Observer passively
Appendix C GigaStor Portable

rev. 1

Dynamic Host Control Protocol (DHCP). For most applications of
Observer, you should assign an address to the analyzer rather than
depending on the DHCP assignment.

Using the portable GigaStor as a probe
Although most administrators usually run the Observer console
directly from the portable GigaStor, in some cases you may want to
use the system as a distributed probe system. The probe software is
included for this purpose.

rev. 1

Using the portable GigaStor as a probe 137
Appendix C GigaStor Portable

138 Using the portable GigaStor as a probe
Appendix C GigaStor Portable

rev. 1

Index

Numerics
10 Gigabit Ethernet 14, 37, 116
Gen2 card 37
GigaStor Portable 134
tapping 19
10/100/1000 37
25901 124
25903 124

A
alarms
WAN 90
Analysis Type 62
ARP Inspection, network forensics preprocessor 105
Assign Port to Virtual Adapter 118ff
Assign Ports to Virtual Adapter 118ff
ATM 34–35

B
Board ID 120
buffer overrun 26
buffer statistics 54, 65
buffer, see capture buffer and statistics buffer
bugtraq 97, 99

C
Cable diagram for the GigaStor Expandable 52ff
capture buffer 26ff, 54
32-bit Windows 55
64-bit Windows 55
expert analysis 62
FIFO 66
forensic analysis 93
IP defragmentation 101
limitations 55
loading a 93
Max Buffer Size 55
overwriting 66
Legend: ff=Figure, t=Table
rev. 1

packet loss 26
physical ports 66
probe instance 113
RAM limitations 55
size 55, 65
swapping to disk 26
TCP stream 102
unused 26, 29
capture card, see Gen2 card
Channel Service Unit, see CSU
CIR 80–81, 84, 86
coax cable 46
Collect GigaStor indexing information by 66
collision test 136
Committed Information Rate 80, 84, 86, 90
copper Ethernet
capture card 15
converting 134
Gigabit 40
GigaStor Portable 136
tapping 19, 40–41ff
copper nTAP 40
CRC-16 34
CRC-32 34
CSU
encapsulation 34–35
HSSI 48
tapping 42–44, 46
WAN statistics 83

D
data circuit-terminating equipment, see DCE
Data Link Connection Identifier, see DLCI
Data Service Unit, see DSU
Data Terminal Equipment, see DTE
DCE
copper Ethernet 40
Fibre Channel 37
optical Ethernet 37

Numerics–D 139
Index

T1/E1 42
WAN alarms 90
WAN statistics 80, 82–83
DCE BECN under CIR 84
DCE FECN under CIR 84
DCE Kbits/s Avg 84
DCE KBits/s Max 84
denial of service 105
DHCP 137
DLCI 80–87
DLCI CIR Setup 81
DMA buffer size 122
DMA copy size 122
DMA enabled 122
DS3
see also HSSI
DLCI 83
fractionalized 34
monitoring 15
probe settings 34
tapping 46–47
DS3/E3 TAP 47ff
DSU
encapsulation 34–35
HSSI 48
tapping 42–44, 46
WAN statistics 83
DTE
WAN alarms 90
WAN statistics 80, 82–83
DTE BECN under CIR 84
DTE FECN under CIR 84
DTE Kbits/s Avg 84
DTE KBits/s Max 84

E
E1
DLCI 83
monitoring 15
probe settings 35–36
tapping 42–45
WAN relay type 35–36
E3
see also HSSI
DLCI 83
fractionalized 34
monitoring 15

140 E–G
Index

probe settings 34
tapping 46–47
Edit Port Description 119ff
Edit Probe Instance
Capture Buffer Memory 26ff
Edit Probe Instance Configure Memory 28ff
Edit Probe Instance Connect to Console 28ff
Edit Probe Instance Name 27ff
Edit Remote Probe Entry 23ff
encapsulation 34–36, 80
Ethernet
see also copper Ethernet
10 Gigabit 14, 116, 134
analysis 80
ARP inspection 105
cables 18, 41
Gigabit 14, 19, 116, 134
GigaStor Portable 134
hub 136
jumbo frame support 31
NIC 18, 136
TAP 18
tapping 37
Expert Probe interface 109ff

F
Fabric 37
Fibre Channel 14
Gen2 card 116
GigaStor Portable 134, 136
tapping 19, 37–38
fibre channel host bus adapter 14, 19
FIFO gauge 59
Forensic Analysis 62, 91
Forensics Settings 94
fractionalized 34–35
frame check sequence 34

G
Gen2 card 18, 40, 115–116
10 Gigabit Ethernet 37
2-port 38
4-port 38
8-port 38
Advanced Settings 122
Board ID 120
cables 38
Legend: ff=Figure, t=Table
rev. 1

daughter board 38
DMA enabled 122
Fibre Channel 37
filter ports 66
Gigabit 37
Gigabit copper 40
Interrupt enabled 122
mirror port 38
passive probe instance 113
performance 113
port assignments 38ff, 40ff
ports 66
probe instance warning 112
properties 120
SFP 14, 116
SPAN port 38
statistics 66
swapping SFP or XFP 116
virtual adapters 116
XFP 14, 116
Gigabit 40–41, 136
defining probe as 117
Ethernet 116, 134
Fibre Channel 14
GigaStor Portable 134, 136
jumbo frame 31
Gigabit Ethernet 14, 19
Gigabit switch 37
Gigabit tab 31
gigabytes 55
GigaStor
buttons 128ff
buttons, meaning of 128, 131
case 127–128ff, 131ff
copper TAP 41ff
drive locations 51
expansion units 14, 19, 37, 50, 52
Expert Probe 110
LEDs 128ff
LEDs, meaning of 128, 131
models 14ff
Observer and 22
optical TAP 39ff
Settings Schedule tab 30ff
versions 14ff
GigaStor Analysis Filter 62
GigaStor capture 114ff
GigaStor Capture Analysis 29
Legend: ff=Figure, t=Table
rev. 1

GigaStor Control Panel 29ff, 54
GigaStor Expandable 14, 51–52
buttons, meaning of 129
case 130ff
connecting expansion units 52
LEDs, meaning of 129
setting IP address 19
turning on 52
GigaStor Instances 27ff
GigaStor Packet Sampling 66
GigaStor Portable 14, 133–137
as probe 137
collision test 136
Fibre Channel 134
traffic generation 136
WAN taps 136
GigaStor probe 117ff
administration 24
redirecting 22

H
HSSI 15, 34, 48–49
probe settings 34
HTTP URI Normalization 103

I
installing 17, 19
Interrupt enabled 122
IP address
DHCP 136
GigaStor 19, 23
GigaStor Portable 136
IPv6 105
NAT 124
setting 19–20
statistics 71
TCP/IP ports 124
VPN 125
IP Defragmentation 101
IP Flow 101
IP masquerading, see NAT
IP Pairs 58
IP Stations 58
IPv6 92

H–I 141
Index

L
LAPB 34–35
load
preprocess settings 101
preprocessor 113

M
MAC address 105
DLCI instead of 80
excluding 65
statistics 71
Top Talkers 86
MAC address tab 86
MAC stations 58
Make Instance Active 120ff
Max Buffer Size 55, 65
megabytes 113
memory management 55
Memory Management tab 25ff
mirror port 38, 41, 116–117
see also SPAN port

N
NAT 124–125ff
Network 1 probe instance 25
Network Forensics 91
Network Intrusion Detection 91–92
network load 65
packet loss 65
viewing 59
network masquerading, see NAT
NIDS 92

O
optical 15, 37, 39, 116, 134
Gigabit Ethernet 19
GigaStor Portable 136

P
packet 101
analyzing 92
decoding 100
loss 26, 65
sampling 66
packet alert threshold 102

142 L–P
Index

packet buffer 62
packet capture 53, 114ff
active instance vs. passive instance 112
active probe instance 113
buffer 29, 54
buffers for 26
decoding 54
dynamic sampling 59
entire packet 65
filtering 61, 87
GigaStor capture 70
GigaStor Portable 134, 136
high-volume 92
load time 62
marker frames 66
partial 59
partial packet 65
reassembling 103
sampling ratio 59
scheduling 70
WAN 87
packet filters 92
packet fragmentation 101
pass-through cable 41
Probe added to Remote Probe Administration and
Redirection 23ff
probe instance 114ff
active 55, 112–114
active vs.passive 112t
assigning memory to 28
assigning to adapter 119
best practices 113
definition of 112
memory requirements 26, 29
memory reserved for 26
memory tuning 55
naming 25
Network 1 25
packet capture 70
passive 112–114
passive to active 120
redirecting 24
reserving memory 55
virtual adapters 119
Probe Instance Redirection 24ff
Probe Options 21ff, 109ff
Probe Properties DS3/E3 Tab 34
Probe Properties Serial T1/E1 Tab 36
Legend: ff=Figure, t=Table
rev. 1

Probe Properties T1/E1 Tab 35
Probe Service Configuration Applet 21ff, 108ff

Q
QLogic 19
Quality of Service 32

T
R

RAID 14, 113–114, 128, 131
RAM
see also buffer
active probe instance 26
buffer size 113
capture buffer size 65
formula 55
limitations 55
packet capture 55, 112
packet loss 26
probe instance 26, 59, 113
releasing 26
statistics 55
TCP stream reassembly 102
tuning 55
unused 29
Windows 55
Rate field 59
Redirecting Probe or Probe Instance 24ff, 125ff
Remote Probe Administration 25ff
Remote Probe Administration and Redirection 22ff
rules profiles 92

S
SAN 14, 19, 37, 40
Screen resolution 59
Select Forensic Analysis Profile 93
serial 36, 44–45, 48
settings profiles 92
SFP 14–15, 37, 40, 116, 134
Gen2 card 116
Snort 62, 92–93, 96–97, 99
IP flow 101
IPv6 92, 105
rules 106
variable name 105
SPAN 15, 38, 41, 116–117, 134
statistics buffer 26, 54
Legend: ff=Figure, t=Table
rev. 1

Statistics interval 59
straight-through cable 38
Subprotocol 34
switch 37
system load 66

T1 82
DLCI 83
monitoring 15
probe settings 35–36
tapping 42–45
WAN relay type 35–36
T1/E1 42
digital 42
digital tap 43ff
serial 44
TAP 18–19, 37–38, 40–45, 48, 116, 136
10/100/1000 optical 37
10GbE optical 37
DS3 46–47ff
DS3/E3 46
E3 46–47ff
Fibre Channel 37
gigabit copper 40
HSSI 48
T1/E1 42
WAN 42
TCP 20, 60, 98, 101–103, 123–124, 136
TCP/IP 20, 123–124, 136
TCP/IP ports 124
TCP/IP settings 20ff
Telnet Normalization 105
Terms of Service 32
Top Talkers 55, 86
Track statistics information per physical port 66
traffic generation 136

U
UDP 60
Update Chart button 59, 66
Update Statistics button 59
Use physical port selections to filter statistics 66

V
Variable Name 105
Q–V 143
Index

virtual adapter 114ff
probe instances 119–120
Virtual Adapters tab 119ff
VPN 125

X
X.25 80, 82, 84–85, 87
XFP 14–15, 116, 134
Gen2 card 116

W
WAN
alarms 80, 88
analysis 80
analyzing 33
bandwidth 80
CIR 80
congestion 84
DCE 82
DS3/E3 46
DTE 82
E1 42
filtering 87
full duplex 80
GigaStor 15
GigaStor Portable 134, 136
HSSI 49ff
monitoring 15
Observer 33
probe 79
probes 87
serial 44
service provider 86
statistics 80
T1 42
TAP 18
tapping 42
triggers 80, 88
WAN alarms 90
WAN card 18
WAN load 80, 84–85
WAN Load by DLCI 84
WAN Serial T1/E1 TAP 45ff
WAN switch 83
WAN Type 34–36
WAN Vital Signs 83
Windows
64-bit 18, 55
Remote Desktop 19
services 21, 108–110
wire speed 134
wireless 66

144 W–X
Index

Legend: ff=Figure, t=Table
rev. 1

145
rev. 1

www.networkinstruments.com
© 2008 Network Instruments, LLC. All rights reserved. Network Instruments, Observer,
and all associated logos are registered trademarks of Network Instruments, LLC.
146
rev. 1



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Page Mode                       : UseOutlines
XMP Toolkit                     : Adobe XMP Core 4.0-c320 44.293068, Sun Jul 08 2007 18:10:11
Creator Tool                    : FrameMaker 8.0
Modify Date                     : 2008:10:21 09:54:10-05:00
Create Date                     : 2008:10:21 09:44:21Z
Metadata Date                   : 2008:10:21 09:54:10-05:00
Format                          : application/pdf
Title                           : gigastor.book
Creator                         : lief
Producer                        : Acrobat Distiller 8.1.0 (Windows)
Document ID                     : uuid:8f45ebfd-49ec-477e-a4d8-5bd9d29be747
Instance ID                     : uuid:7a80773c-4437-4cbe-a255-aa54ddc9f8cc
Page Count                      : 146
Author                          : lief
EXIF Metadata provided by EXIF.tools

Navigation menu